Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "static forces" wg kryterium: Wszystkie pola


Tytuł:
A Comparative Assessment of the Impact of Different Occupations on Workers’ Static Musculoskeletal Fitness
Autorzy:
Chandra, A. M.
Ghosh, S.
Iqbal, R.
Sadhu, N.
Powiązania:
https://bibliotekanauki.pl/articles/90250.pdf
Data publikacji:
2007
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
occupations
repetitive movements
static muscular forces
musculoskeletal disorders
dynamometry
Opis:
An ergonomic assessment of the involvement of static muscular forces like back strength, grip strength and pinch strength in different occupations was made. A study was conducted on 45 normal adult males (15 subjects per group) which included video display terminal (VDT) operators, industrial workers and safety inspectors. Their maximum back strength, handgrip strength and pinch strength were measured with dynamometers. The observed values of back strength were significantly lower in VDT operators while significantly higher in safety inspectors and moderate in industrial workers. The values of grip strength and pinch strength of all sample groups were more or less similar. The findings clearly indicate that static muscular strength varies significantly in different occupations. Heavy static muscular load might lead to an accumulation of metabolic waste and toxins on the back resulting in lower back strength in VDT operators and industrial workers.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2007, 13, 3; 271-278
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of dynamic forces in new construction design for beamless sucker-rod pumping units
Ocena sił dynamicznych w nowym rozwiązaniu konstrukcyjnym zespołów pomp żerdziowych bez żurawia
Autorzy:
Ahmedov, Beyali
Hajiyev, Anar
Powiązania:
https://bibliotekanauki.pl/articles/1834259.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
pumping unit
balancer
rotor
crank
counterweight
static forces
dynamic forces
rod suspension point
zespół pompowy
wyrównywacz
wirnik
korba
przeciwwaga
siły statyczne
siły dynamiczne
punkt zawieszenia żerdzi
Opis:
Artykuł omawia zagadnienie określenia sił dynamicznych działających w punkcie podparcia żerdzi w czasie eksploatacji odwiertu w nowym rozwiązaniu konstrukcyjnym zespołów pompowych bez żurawia, zależnych od kąta obrotu korby i bezwymiarowych parametrów kinematycznych, charakteryzujących zależność między długością korby a długością żerdzi i względną mimośrodowością. Stwierdzono, że wartość obciążeń dynamicznych w kolumnie żerdzi zależy od rodzaju wahacza i od kierunku obrotów korby. Ponadto jednym z niekorzystnych czynników eksploatacji zespołów pompowych jest fakt, że siła w punkcie zawieszenia żerdzi jest stale skierowana w dół, a jej wartość zmienia się w trakcie ruchów wypolerowanej żerdzi w dół i w górę, co prowadzi do nierównego obciążenia silnika elektrycznego. Ten tryb pracy silnika i przekładni jest nieprawidłowy i powoduje ostry spadek ich sprawności. Aby wyrównać obciążenie przekładni i silnika w czasie jednego cyklu pracy oraz zmniejszyć moc silnika wykonującego ten proces równoważenia, w proponowanej konstrukcji równoważenia zespołu pompowego zastosowano kombinację równoważenia składającą się z przeciwciężarów przesuwnych i obrotowych. W tym celu zbadano metodę równoważenia nowej konstrukcji strukturalnej zespołu pompowego i zaproponowano wyrażenia analityczne do określenia wagi przeciwciężarów przesuwnych i obrotowych, kiedy punkt zawieszenia żerdzi przesuwa się w górę i w dół, używając równoważenia łączonego. Artykuł omawia warianty określenia sił dynamicznych w zespole pompowym ropy niezrównoważonym (bez zastosowania przeciwwag) i z kombinacją sposobów zrównoważenia (przez zastosowanie przeciwwag przesuwnych i obrotowych).
Źródło:
Nafta-Gaz; 2020, 76, 5; 299-310
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of a calculation fem model of the test static set-up of pipe conveyor for analysis of contact forces
Autorzy:
Fedorko, G.
Molnár, V.
Powiązania:
https://bibliotekanauki.pl/articles/102281.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pipe conveyor
simulation
analysis
contact forces
Opis:
Experimental research in the field of pipe conveyors is a difficult matter and yet necessary in order to answer the questions regarding the motion resistances and contact resistances of pipe conveyors, loading of the conveyor belts etc. These research activities can be performed not only during the actual operation of pipe conveyors, but also by means of the special laboratory test set-ups combined with the application of the computational simulation models. The main task of this paper is to assess the creation of a suitable simulation model of the test set-up for a specified pipe conveyor developed with regard to realisation of the FEM analyses, using the software product Abaqus, as well as presentation of its application possibilities.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 2; 220-225
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Deteriorated steel culvert under static loading
Autorzy:
Kunecki, B.
Janusz, L.
Korusiewicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/383576.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
full-scale test
corrosion
internal forces
deformation
HelCor
Opis:
The paper describes full-scale tests of a 7,25 m long corrugated steel pipe with a diameter of 1.40 m. The corrugation pattern was 125x26mm and the steel was 2 mm thick. The backfill height over the pipe crown was 0,5 m. The deterioration of the tested steel pipe was simulated by removing a part of its bottom. Strain gauges and optical prisms were installed on the metal surface to determine the stresses, internal forces in the metal shell and additionally its deformation. The results of the measurements are presented as graphs and tables. The main goal of the full-scale tests was to assess the performance of the deteriorated steel pipe subjected to static loads and to evaluate the changes in the distribution of the internal forces, caused by the increasing corrosion of the bottom part of the tested pipe.
Źródło:
Archiwum Instytutu Inżynierii Lądowej; 2017, 23; 145-152
1897-4007
Pojawia się w:
Archiwum Instytutu Inżynierii Lądowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praca statyczna rusztowania pod działaniem rzeczywistego oraz normowego obciążenia wiatrem
Static work of scaffolding loaded by actual and standards driven wind forces
Autorzy:
Jamińska, P.
Powiązania:
https://bibliotekanauki.pl/articles/390943.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
rusztowanie
wiatr
zalecenia normowe
analiza statyczna
scaffolding
wind
static analysis
standards
Opis:
W niniejszej pracy wykonano obliczenia statyczne konstrukcji rusztowania pod oddziaływaniem wiatru przyjętego według zaleceń normowych oraz na podstawie symulacji komputerowych przepływu powietrza wokół budynku prostopadłościennego z rusztowaniem ustawionym przy jednej ze ścian. Na podstawie obliczeń przeprowadzonych dla rusztowania przy różnych kątach natarcia wiatru zestawiono maksymalne wartości: naprężeń w pionowych elementach ram i w stężeniach; sił osiowych w elementach kotwiących. Ponadto wykonano obliczenia stateczności konstrukcji. Przeprowadzone porównanie, wskazuje że siły pochodzące od rzeczywistego obciążenia wiatrem znacznie różnią się kierunkiem, zwrotem oraz wartością od sił zalecanych w normach. Niedoszacowanie obciążenia wiatrem może prowadzić do przekroczenia nośności w elementach rusztowania, a w konsekwencji do katastrofy budowlanej.
This paper presents static analyzes of scaffolding loaded by wind according to Eurocode recommendations and on the basis of computer simulations of air flow around a rectangular building with a scaffolding assembled at one of the walls. On the basis of calculations performed for the scaffold at different angles of wind attack, the maximum values of the stress in the vertical elements of the framework and in the braces are showed, as well as axial forces in the anchors. In addition, critical buckling load analyses were also performed. The comparison indicates that the forces coming from the actual wind loads differ significantly in direction, sense and magnitude from the forces prescribed in the standards. Underestimated wind load can lead to the state of exceeded capacity in scaffolding elements, and consequently to the construction disaster.
Źródło:
Budownictwo i Architektura; 2014, 13, 2; 341-348
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the Static Loading of a Raft Unconnected to a Pile on the Pile Displacements Tested in Field Conditions
Autorzy:
Sedin, Volodymyr
Bikus, Kateryna
Kovba, Vladyslav
Kononov, Denys
Zahilskyi, Vitalii
Powiązania:
https://bibliotekanauki.pl/articles/396774.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
pile foundation
static loading
friction forces
raft
fundament palowy
obciążenia statyczne
siły tarcia
Opis:
We present the results of a static pile-raft interaction test in field conditions. The pile and the raft were unconnected. The static loading on the raft affected the displacements of the pile due to the skin friction. The displacements were also observed for another pile, placed at the 3-metre distance.
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 2; 22-30
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System wspomagający rozwiązywanie belek dla wariantowych obciążeń statycznych
Aid system of beams solution for variant static loads
Autorzy:
Łoboda, M.
Krysztofiak, A.
Dworecki, Z.
Powiązania:
https://bibliotekanauki.pl/articles/289884.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
zginanie
belka
siły wewnętrzne
bend
beams
internal forces
Opis:
Niezależnie od istniejących profesjonalnych systemów inżynierskich wspomagających proces projektowania istnieje zapotrzebowanie na oprogramowanie o charakterze edukacyjnym w zakresie obliczeń statycznych prętów i belek. Niniejsza praca, przynajmniej częściowo, próbuje tę lukę wypełnić. Przedstawiony program wyznacza reakcje w podporach, siły normalne, styczne i momenty gnące wraz z ich wykresami.
Beside the existing professional engineering computer systems for help the projection process exists the demand on software at educational character in range the static calculations of rods and beams. Present work, at least partly, it tries this gap to fill. Introduced programme calculates reaction in supports, normal and contiguous forces, and bend moments together with their graphs.
Źródło:
Inżynieria Rolnicza; 2005, R. 9, nr 14, 14; 221-227
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Force ratio in masticatory muscles after total replacement of the temporomandibular joint
Autorzy:
Vilimek, M.
Horak, Z.
Baca, W.
Powiązania:
https://bibliotekanauki.pl/articles/307085.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dynamika odwrotna
optymalizacja statyczna
staw skroniowo-żuchwowy
siły mięśniowe
inverse dynamics
static optimization
temporomandibular joint
muscle forces
mastication
FE analyses
Opis:
The temporomandibular (TM) joint is one of the most active joints in the human body, and any defect in this joint has a significant impact on the quality of life. The objective of this study was to analyze changes in the force ratio after TM joint replacement on contralateral TM joint loading. Implantation of an artificial TM joint often requires removal of 3 of the 4 masticatory muscles (activators). In order to perform true loading of the TM joint, loading during mastication was investigated. Input kinematic variables and mastication force were experimentally examined. The inverse dynamics approach and static optimization technique were used for solution of the redundant mechanism. Muscle forces, and reactions in the TM joint were calculated. We modified the model for several different tasks. The m. temporalis and m. masseter were removed individually and together and the forces of mastication on the TM joint were calculated for each variation. To evaluate the results, a parametric numerical FE analysis was created to compare the magnitude of the TM joint loading during the bite process for four different muscle resections. The results show an influence relative to the extent of muscle resection on contralateral TM joint loading in a total TM joint replacement. The biggest increase in the loading magnitude on the contralateral TM joint is most evident after m. masseter and m. temporalis resection. The results from all simulations support our hypothesis that the greater the extent of muscle resection the greater the magnitude of contralateral TM joint overloading.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 3; 131-136
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Storage as an important element in maintaining technical serviceability of military equipment
Autorzy:
Jaskula, L.
Dzida, J.
Powiązania:
https://bibliotekanauki.pl/articles/30147044.pdf
Data publikacji:
2018
Wydawca:
Akademia Wojsk Lądowych imienia generała Tadeusza Kościuszki
Tematy:
corrosion
storage method
dynamic dehumidification
static dehumidification
greaseless method
technical maintenance
Opis:
The article presents the methods of storing equipment used in the Polish Armed Forces and the description of their application. The overall scope of maintenance works performed on the equipment during storage preparation, as well as the scope of checks and inspections executed during the equipment storage and after removal from storage are outlined. Moreover, the causes of corrosion, its effects and ways of prevention are discussed.
Źródło:
Scientific Journal of the Military University of Land Forces; 2018, 50, 3(189); 155-165
2544-7122
2545-0719
Pojawia się w:
Scientific Journal of the Military University of Land Forces
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statyczne ujęcie metody punktów masowych do wyznaczenia sił osiowych w prętach kratownicy płaskiej
The static approach to point mass method for determination of axial forces in a truss
Autorzy:
Paluch, M.
Powiązania:
https://bibliotekanauki.pl/articles/349039.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
kratownica
pręt
siła osiowa
węzeł
przemieszczenie węzła
truss
bar of a truss
axial force
connecting joint displacement
Opis:
Kratownice płaskie stosowane są zarówno w budownictwie naziemnym, jak i podziemnym. Projektant takich konstrukcji przy doborze przekrojów poprzecznych prętów musi znać siły osiowe w nich działające, przemieszczenia węzłów i siły reakcji podpór. W pracy omówiono metodę, która jest bardzo wygodna do obliczeń i może być całkowicie zautomatyzowana. Jest konkurencyjna w stosunku do metody elementów skończonych.
Flat trusses are used in surface building as well as underground building industry. The designer of such constructions has to know the axial forces, displacement of connecting joints and bearing reaction forces in order to choose the appropriate bar sections. This work presents a very convenient method for calculating forces in a bar of a truss. The method could be entirely automated and is considered as competitive with the finite-element method.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 3/1; 137-151
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies