Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "solar analysis" wg kryterium: Wszystkie pola


Tytuł:
Analysis of Regional Global Climate Changes due to Human Influences
Autorzy:
Zurbenko, Igor G.
Potrzeba-Macrina, Amy L.
Powiązania:
https://bibliotekanauki.pl/articles/1065361.pdf
Data publikacji:
2019
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Kolmogorov-Zurbenko time and space filtration
separation of scales
total solar irradiation
Opis:
In recent years global climate change has been the focus of much scientific research as well as a focal point in the media. A recent period of significant increases in global temperatures has caused much concern. This period was followed by a relative slowdown, which in turn has created confusion. There are two major reasons for global temperatures variations, one of which is oscillations of total solar activity in time. Another reason is atmospheric pollutants causing greenhouse effects. Obviously, solar activities cannot be controlled, but relevant pollutants can. Since these two reasons are independent components of global temperature variations, they must be separated in order to adequately study global climate changes. Solar irradiation transferred to Earth is proportional to sunspot numbers, which have been recorded for centuries. The purpose of this paper is to separate this solar component from long-term temperature data, thus leaving for examination the component created by human activities. This separation of components and examination thereof can be performed at numerous locations over Earth, that is, the time component and rates of its increases can be mapped over the globe. This paper smooths these images to display the different rates of temperature increases over different global regions, which allows for a comparison of different regional efforts to fight climate changes. In some regions, negative rates were occurring as of recent years, but other regions those rates are becoming alarmingly high. The average rate of temperature increase due to human influence over the planet is remaining positive. The regional comparisons offer a great opportunity for assessing different methods of control of global climate changes.
Źródło:
World Scientific News; 2019, 132; 1-15
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Solar Energy Supply Fluctuations to Earth and Climate Effects
Autorzy:
Zurbenko, Igor G.
Potrzeba-Macrina, Amy L.
Powiązania:
https://bibliotekanauki.pl/articles/1065091.pdf
Data publikacji:
2019
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Kolmogorov-Zurbenko filter
regional climate change
separation of scales
spectral analysis
sunspots numbers
total solar irradiation
Opis:
A major source of energy on Earth is solar irradiation. This paper uses the Kolmogorov-Zurbenko filter to smooth and examine sunspot numbers and proves that solar irradiation levels near Earth are strictly proportional to sunspot numbers. This paper also examines the transport of that energy through the atmosphere to Earth’s surface. Long term air temperatures on the surface of Earth perfectly follow the cosine square law along latitudes. Time components of long term temperatures have oscillations which follow oscillations in sunspot numbers, but due to the regular delays in energy transmission they are delayed 4-7 years. Cloud formations and vapor accumulations also contribute to those delays, which have a well-organized time-space structure. The main purpose of this paper is the numerical identification of human influence over changes in solar activities, which may allow researchers to identify the effects of various sources of those influences. This evaluation can only be achieved by separating the scales in order to avoid any false influence from other scales. The clear separation of scales can only be achieved using the Kolmogorov-Zurbenko filter.
Źródło:
World Scientific News; 2019, 120, 2; 111-131
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and Numerical Analysis of Photovoltaics System Improvements in Urban Area
Eksperymentalna i numeryczna analiza usprawnień systemu fotowoltaicznego w terenie miejskim
Autorzy:
Żołądek, M.
Sornek, K.
Papis, K.
Figaj, R.
Filipowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/396710.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
renewable energy sources
solar energy
sun-tracking devices
TRNSYS
dynamic simulation
odnawialne źródła energii
energia słoneczna
systemy nadążne
symulacja dynamiczna
Opis:
Nowadays, photovoltaic systems installed in urban areas have to be an essential part of distributed generation systems, and lead to improve energy efficiency of buildings. The paper describes the operation aspects of the 7,5 kWp photovoltaic installation located on the roof of the didactic building of AGH University of Science and Technology. The significant part of the roof Is occupied by HVAC installation, so the periodic shading is occurring. It makes, that a level of energy generated in the PV system is lower than expected. The first part of the test was focused on the validating model of the installation and determine its impact on the CO2 emissions. Then, modifications in the arrangement of the panels were considered (redirecting of additional light stream). Moreover, an economic and environmental analysis of proposed improvements were conducted.
Obecnie instalacje fotowoltaiczne zainstalowane na obszarach miejskich muszą stanowić istotną część rozproszonych systemów wytwarzania energii i prowadzić do poprawy efektywności energetycznej budynków. Najpopularniejszym sposobem montażu paneli fotowoltaicznych na dachach budynku jest zamontowanie ich pod optymalnym kątem względem słońca. Niestety w wielu miejskich przypadkach niemożliwe jest umieszczenie fotowoltaiki na najlepszej dostępnej pozycji ze względu na efekt cieniowania lub specjalne warunki budowlane. W artykule opisano aspekty eksploatacyjne instalacji fotowoltaicznej o mocy 7,5 kWp zlokalizowanej na dachu budynku dydaktycznego Akademii Górniczo-Hutniczej. Znaczna część dachu jest zajęta przez instalację HVAC, więc występuje okresowe zacienienie. To sprawia, że poziom energii generowanej w systemie PV jest niższy niż oczekiwano. Przedstawiono analizę możliwości zwiększenia wydajności instalacji za pomocą narzędzia Transient System Simulation (TRNSYS). Pierwsza część badania koncentrowała się na walidacji modelu instalacji i określeniu jej wpływu na emisję CO2. Następnie rozważono modyfikacje układu paneli (przekierowanie dodatkowego strumienia świetlnego). Ponadto przeprowadzono analizę ekonomiczną i środowiskową proponowanych ulepszeń.
Źródło:
Civil and Environmental Engineering Reports; 2018, No. 28(4); 13-24
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the influence of the heat-absorbing surface of an air-cooled solar collector on its thermal and mechanical properties
Autorzy:
Zhelykh, Vasyl
Ulewicz, Małgorzata
Kozak, Krystyna
Savchenko, Olena
Kasynets, Mariana
Powiązania:
https://bibliotekanauki.pl/articles/88616.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
solar air collector
heat-absorbing plate
flow turbulators
thermal power
air channel
powietrzny kolektor słoneczny
płyta pochłaniająca ciepło
turbulatory przepływowe
energetyka cieplna
kanał powietrzny
Opis:
This paper presents the analysis of existing forms of heat absorbing surfaces of air solar collectors, which gained the greatest popularity in the world. The obtained data allowed to conclude that there is a need for the development of solar collectors with air as a coolant with an improved form of heat absorber, which will reduce the operational and capital costs of solar systems and allow the efficient use of such structures in a moderate climate without additional mechanisms for the transfer of coolant. The use of computer simulation helped to compare the thermal characteristics of air-borne solar collectors of a different design. The substantiation of the expediency of installing as a heat absorber of flow turbulators in the form of a screw has been fulfilled, as well as the height of the air channel of the solar collector has been determined, in which the maximum heating of the transfer medium is observed. In addition, the loss of pressure in the air channel of the solar collector with flow turbulators was determined and the comparison of the obtained data with the values of pressure losses in the air collector of the matrix type and the air collector with V-shaped ribs was made.
Źródło:
System Safety : Human - Technical Facility - Environment; 2019, 1, 1; 481-489
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Korzyści środowiskowe z wykorzystania systemów solarnych na przykładzie budynku jednorodzinnego
Environmental benefits from solar systems -the example of detached house
Autorzy:
Żelazna, A.
Pawłowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/960239.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
analizy środowiskowe
ocena cyklu życia
GWP
systemy solarne
environmental analysis
Global Warming Potential
solar systems
Opis:
Jednym z naczelnych postulatów koncepcji rozwoju zrównoważonego jest zmniejszenie poziomu zużycia energii produkowanej ze źródeł konwencjonalnych. Dlatego odnawialne źródła energii, takie jak energia słoneczna, stają się coraz bardziej popularne w wielu zastosowaniach. Najczęściej stosowane sposoby wykorzystania energii słonecznej to podgrzewanie ciepłej wody użytkowej oraz produkcja energii elektrycznej poprzez zastosowanie fotowoltaiki. W niniejszym artykule zaprezentowano rezultaty analizy środowiskowej wykorzystania kolektorów słonecznych w budynku jednorodzinnym zlokalizowanym na Lubelszczyźnie. Porównanie z tradycyjnymi metodami produkcji ciepłej wody użytkowej wskazuje na korzyści środowiskowe, wynikające ze stosowania systemów solarnych. W analizie wykorzystano metodologię podstaw oceny cyklu życia (LCA) oraz metodę szacowania potencjału tworzenia efektu cieplarnianego Global Warming Potential (GWP). Metoda GWP została wykorzystana do oszacowania ilości ekwiwalentu C02 emitowanego do atmosfery w każdym z analizowanych systemów.
The necessity to reduce energy consumption from conventional sources is one of the most important requirements of the sustainable development concept. That is why renewable energy sources, like sun energy, become more and more popular in many applications. The most commonly used systems are Solar Hot Water (SHW) and Photovoltaics (PV) for electricity production. This paper presents the results of environmental analysis of the possibility to use SHW system in detached house located in Lublin, Poland. The comparison of traditional methods of water heating with the alternative technologies like sun energy shows the environmental benefits from solar systems. The methods used for analysis are the basis of Life Cycle Assessment (LCA) and Global Warming Potential (GWP). The GWP method was used to appoint the amounts of CO2 emitted to enyironment in every examined process.
Źródło:
Proceedings of ECOpole; 2011, 5, 2; 649-654
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of the solar power plant performance in temperate climate
Autorzy:
Zdyb, A.
Dragan, P.
Jaremek, A.
Powiązania:
https://bibliotekanauki.pl/articles/105126.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
photovoltaics
grid connected solar plant
photovoltaic performance
inclination angle
tilt angle
Opis:
Due to gradual depletion of fossil fuels resources and emission of harmful chemicals accompanying the combustion process, the interest in alternative energy sources still increases. Among many kinds of alternative sources, solar radiation is very special because of its wide availability and large technical potential. Photovoltaic systems providing the electric energy are used in many countries. The most important part of photovoltaic system is a module, which parameters (e.g. efficiency, rated power, temperature coefficients of power and efficiency, short circuit current, open circuit voltage) are determined in laboratory tests under Standard Test Conditions (STC: 25°C, 1,000 W/m2 , air mass 1.5). However, in real outdoor conditions the modules exhibit lower efficiency since local climate influences their performance and different external factors generate energy losses in the whole system. The aim of this work is the performance analysis of a solar power plant connected to the grid, which total rated power is 2.985 MW and it works in temperate climate in eastern Poland. Insolation in the location was estimated according to Solargis data and the role of the modules tilt angle, of which the value is non-typical for the considered location was studied. The tilt angle smaller than optimal angle allows increasing the amount of the solar radiation collected in the summer period. The electric energy production based on the inverters data in 2016 and 2017 as well as yearly yield are presented. The results are compared to data coming from other solar power plants, also located at high latitude.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 1; 73-79
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Analysis of Active Regions 11036 Characteristics Leads To Solar Flare Class C7.2 Phenomena
Autorzy:
Zainol, N. H.
Hamidi, Z. S.
Husien, Nurulhazwani
Ali, M. O.
Sabri, S. N. U.
Shariff, N. N. M.
Faid, M. S.
Monstein, C.
Ramli, Nabilah
Powiązania:
https://bibliotekanauki.pl/articles/1192106.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Solar Radio Burst Type II
solar flare
Callisto network
active region
Opis:
The solar flares are generated from electromagnetic radiation which is sudden oscillation of the stored energy in the magnetic field of the sun. Flares are categorized according to their brightness as C, M and X, where X is the brightest. The X class flares caused a long-time solar storm and ionospheric radio waves sparkling. The moderate level M class flares mostly effect polar cups and cause short-time radio sparkling. However, the C class flares are weaker than the X and M flares. In this work, we present an active region from the disturbance of magnetic field on the area of the Sun and may lead to powerful event if the magnetic field become stronger. The CALLISTO system network that has been installed in Gauri, India observed data that contain Solar Radio Burst Type II (SRBT II) occurred on 22nd December 2009 at 04:57 UT to 05:02 UT. Five active regions were obtained from online data via internet from the Space Weather website and the Solar Monitor website. All data and information from these sources assist in analyze of the phenomena. The magnetic field and X-ray flux, proton density increase the possibilities that SRBT II observed by CALLISTO network to generate powerful solar flare. When X-ray flux level was at maximum, then solar flare was at peak point. However, solar activity level was low because among of five active regions present, only one C-class flare event occurred. The most active region that contributes this event is an AR11036 with C-class flare.
Źródło:
World Scientific News; 2016, 45, 2; 80-91
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Site selection for solar power plant in Zaporizhia city (Ukraine)
Autorzy:
Yankiv-Vitkovska, Liubov
Peresunko, Bohdan
Wyczałek, Ireneusz
Papis, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/145422.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrownia
analiza wielokryterialna
AHP
power plants
multicriteria analysis
QGIS
Opis:
Renewable energy from solar power plants is becoming more and more popular due to the depletion of raw materials and reduction of dependence on oil and gas and is also harmless to the natural environment. The management and rational use of land resources is currently a pressing problem in the world, including in Ukraine. One of the solutions is the development of technologies for the use of these areas and the establishment of environmentally friendly technologies for reducing air pollution, namely electricity facilities – solar power plants based on the use of photovoltaic panels. Choosing the right location for obtaining solar energy depends on many factors and constraints. Optimal location of solar farms is important to maximize the beneficial features of projects while minimizing the negative. A method of finding places in the vicinity of large cities that could be suitable for installing power plants was developed. The proposed method uses an analytical hierarchical process, analytical network process, Boolean logic and weighted linear combination. It has been implemented in the QGIS program. The method was successfully used for the city of Zaporizhia, but it can be directly implemented in any other region. That is why the presented works constitute a scheme that can be easily used to estimate large areas in order to optimally choose a place for a solar park in the vicinity of large cities. Such a model can be very useful for investors to find potential locations for solar energy before conducting detailed field research.
Źródło:
Geodesy and Cartography; 2020, 69, 1; 97-116
2080-6736
2300-2581
Pojawia się w:
Geodesy and Cartography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical simulation and experimental validation of solar greenhouse dryer using finite element analysis for different roof shapes
Autorzy:
Yadav, Aditya Arvind
Prabhu, Pravin A.
Bagi, Jaydeep S.
Powiązania:
https://bibliotekanauki.pl/articles/1819128.pdf
Data publikacji:
2021
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
solar greenhouse dryer
drying
moisture removal
solar thermal energy
finite element analysis
szklarnia
suszarnia słoneczna
suszenie
usuwanie wilgoci
energia słoneczna
analiza elementów skończonych
Opis:
The present study focuses on the numerical simulation and experimental validation of a Solar Greenhouse Dryer (SGHD). The Solar Dryers are the devices which uses solar energy to dry substances, especially crops with high moisture content, and the word Greenhouse means protection of crops from excess hot or cold climatic conditions and unwanted pests. Thus, Solar Greenhouse Dryer is a device which utilizes solar energy for drying of crops with high moisture content and prevents it from excess climatic conditions and provides optimum range of temperature and prevents the dried product from pests and dust while drying. The numerical simulation of SGHD was performed using Finite Element Analysis software ANSYS 2020 R2. Initially three different roof shapes were modelled using software CATIA V5 R3 namely triangular, trapezoidal and dome shape. The modelled SGHDs was then introduced to ANSYS domain for numerical analysis. The models were initially meshed in ANSYS workbench with unstructured tetrahedral structure of mesh over all the domains. The Solar Ray tracing content was used for numerical simulation of dryers, the solar ray tracing is used to predict direct illumination energy source produced by sun at experimental site. The experiment for no-load test was conducted at Bahe Borgaon, Dist- Sangli, Maharashtra, India at 17.115°N and 74.33°E.
Źródło:
Journal of Mechanical and Energy Engineering; 2021, 5, 1; 69--80
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exergy analysis of double-circuit flat solar collector with thermosyphon circulation
Analiza egzergetyczna kolektora słonecznego dwuobwodowego z obiegiem termosyfonu
Autorzy:
Wójcik, Waldemar
Kalimoldayev, Maksat
Amirgaliyev, Yedilkhan
Kunelbayev, Murat
Kalizhanova, Aliya
Kozbakova, Ainur
Merembayev, Timur
Powiązania:
https://bibliotekanauki.pl/articles/408460.pdf
Data publikacji:
2019
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
temperature
solar energy
analysis
mathematical model
temperatura
energia słoneczna
analiza
model matematyczny
Opis:
In the present work, an exergy analysis was done of two-circuit flat solar collector with thermosiphon circulation. The article presents a mathematical model of energy and exergic analysis of flat solar collectors, as well as calculations of solar radiation efficiency, temperature, flow rate of the fluid, exergy rates and exergy loss rates are done. The significance of the results achieved is high, since experimental studies can detect inefficient components of the solar heating system. The exergetic efficiency of a dual-circuit flat solar collector with a thermosiphon circulation describes irreversibility of the process according to thermodynamic parameters. This is caused by a large the degree of overheating achieved at the end of the processes of compression and evaporation, which leads to large differences in heat exchange temperature based on the heat pump cycle. The exergy efficiency value for the entire system is 70. Maximum values energy efficiency and exergy at noon, 32.5% and 2.23%, respectively. The efficiency of exergy is 4%, and the highest the loss of exergy is the difference between the absorber plates and the sun, accounting for 52.86% of the total exergy rate.
W niniejszej pracy wykonano analizę egzergetyczną płaskiego kolektora słonecznego dwuobwodowego z cyrkulacją termosyfonową. W artykule przedstawiono model matematyczny analizy energetycznej i egzergetycznej płaskich kolektorów słonecznych, a także obliczono sprawność promieniowania słonecznego, temperaturę, natężenie przepływu cieczy, wskaźniki egzergii i wskaźniki strat egzergetycznych. Znaczenie osiągniętych wyników jest duże, ponieważ badania eksperymentalne mogą wykryć nieefektywne elementy systemu ogrzewania energią słoneczną. Egzergetyczna sprawność dwuobwodowego płaskiego kolektora słonecznego z obiegiem termosyfonowym opisuje nieodwracalność procesu według parametrów termodynamicznych. Jest to spowodowane dużym stopniem przegrzania osiąganym pod koniec procesów sprężania i odparowywania, co prowadzi do dużych różnic w wymianie ciepła w oparciu o cykl pompy ciepła. Efektywność energetyczna całego systemu wynosi 70. Maksymalne wartości sprawności energetycznej i egzergii w południe, odpowiednio 32,5% i 2,23%. Efektywność egzergii wynosi 4%, a największą stratą egzergii jest różnica pomiędzy płytami absorbera a słońcem, stanowiąca 52,86% całkowitego wskaźnika egzergii.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2019, 9, 3; 35-39
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie danych z lotniczego skaningu laserowego do analizy nachylenia i ekspozycji dachów w celu montażu kolektorów słonecznych
Analysis of exposure and slope of roofs for photovoltaics installation based on airborne scanning data
Autorzy:
Witkowska, A.
Bielecka, E.
Powiązania:
https://bibliotekanauki.pl/articles/210567.pdf
Data publikacji:
2014
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
lotniczy skaning laserowy
słoneczny kataster
numeryczny model pokrycia terenu
zacienienie
panele słoneczne
NMPT
airborne lasers scanning
solar cadastre
digital surface model
DSM
solar radiation
shadowing, photovoltaics
Opis:
Ograniczone zasoby złóż paliw oraz ich rosnąca cena na rynku, a także postępujące w ostatnich latach zmiany klimatyczne sprawiły, że coraz więcej uwagi poświęca się środowisku oraz odnawialnym źródłom energii. Wychodząc naprzeciw wymienionym problemom, w artykule podjęto próbę analizy geometrii dachów wybranego osiedla domów jednorodzinnych w kontekście montażu kolektorów słonecznych. Do badań nad przedstawionym zagadnieniem wykorzystano dane pochodzące z lotniczego skaningu laserowego oraz obrysy budynków. Na użytek gospodarstw domowych dachy budynków wydają się być najodpowiedniejszą lokalizacją do montażu kolektorów słonecznych, dlatego przeprowadzone analizy zawężono do tych obszarów. Z uwagi na specyfikę samych urządzeń w analizach uwzględniono kilka czynników, takich jak: efekt zacienienia, minimalna powierzchnia, jak również nachylenie czy orientacja połaci dachowych. Właściwie dobrane kryteria klasyfikacyjne rastrowych modeli spadków, ekspozycji i usłonecznienia umożliwiły wskazanie obszarów dogodnych pod względem montażu kolektorów słonecznych, a tym samym stały się podstawą do określenia indywidualnych „predyspozycji słonecznych” dachów zabudowy mieszkalnej.
The limited amount of fossil fuels, their growing price on the market and progressive climatical changes last years caused that more attention have been focused on environment and the renewable sources of energy. This paper presents the results of the analysis aiming at selection of roof areas suitable for the installation of photovoltaic devices. Airborne lasers scanning data combined with the digital topographic data were the basis for delimitation of the slope, exposure, and not shaded roof area.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2014, 63, 2; 103-115
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wartości pomiarowych i literaturowych natężenia całkowitego promieniowania słonecznego
Analysis of measurement and litarature`s values of intensity of total solar radiation
Autorzy:
Wilk-Słomka, B.
Ślusarek, J.
Powiązania:
https://bibliotekanauki.pl/articles/362681.pdf
Data publikacji:
2009
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
natężenie całkowitego promieniowania słonecznego
klimat lokalny
intensity of total solar radiation
local climate
Opis:
W artykule przedstawiono analizę porównawczą wartości pomiarowych (lokalnych) natężenia całkowitego promieniowania słonecznego padającego na płaszczyznę poziomą z danymi literaturowymi (normy). Analiza została przeprowadzona na podstawie pomiarów uzyskanych na stanowisku badawczym Zakładu Budownictwa Ekologicznego w latach 1994-2007 r.
In the paper literature's (standards) data and local values (registered at research stand in 1994-2007) of total solar radiation intensity were analyzed. Pursued analysis shows divergence. So, it can be concluded that knowledge about climatic parameters in given place (region) is very important to make calculations that show real energatic need of buildings.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2009, T. 4; 187-192
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zastosowania pasywnych systemów pozyskiwania energii słonecznej w budynku jednorodzinnym
Analysis of using passive solar energy systems at single-family building
Autorzy:
Wilk-Słomka, B
Powiązania:
https://bibliotekanauki.pl/articles/362506.pdf
Data publikacji:
2011
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
pasywny system pozyskiwania energii słonecznej
procesy heliotermiczne
system zysków bezpośrednich
passive solar energy system
heliothermic processes
direct heat gain system
Opis:
W artykule przedstawiono analizę wpływu zastosowania pasywnych systemów pozyskiwania energii słonecznej na charakterystykę energetyczną budynku jednorodzinnego. Wykorzystanie systemu zysków bezpośrednich poprzez zastosowanie okien to najprostsza forma pasywnego pozyskiwania energii promieniowania słonecznego. W analizach rozpatrywano następujące parametry: powierzchnia okien, współczynnik przenikania ciepła okien, rodzaj szklenia, ilość szyb, współczynnik przepuszczalności promieniowania słonecznego. Dodatkowo analizowano wpływ zastosowania rolet zewnętrznych na bilans cieplny budynku.
In the article an analysis of using passive solar systems at the single-family building was described. Using the direct heat gain system by the windows usage is the easiest form of passive solar system. The solar heat gain depends on: the surface of windows, the coefficient of windows and glass heat transfer, the type of glazing, the kind of window’s profile and the permeability of the solar radiation coefficient. Additionally, the influence of using roller blind on the heat balance of the building was being analysed. An important problem, which we must consider during deliberations of using passive solar systems is the overheating rooms.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2011, T. 6, nr 3, 3; 77-80
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Solar pyrolysis and gasification of the sewage sludge - produced fuel properties analysis
Piroliza solarna oraz zgazowanie osadów ściekowych - analiza właściwości powstałych paliw
Autorzy:
Werle, Sebastian
Sobek, Szymon
Kaczor, Zuzanna
Powiązania:
https://bibliotekanauki.pl/articles/127348.pdf
Data publikacji:
2020
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
solar energy
sewage sludge conversion
artificial light source
pyrolysis
gasification
energia słoneczna
wykorzystanie osadów ściekowych
sztuczne źródło światła
piroliza
zgazowanie
Opis:
Sewage sludge is considered as a biomass due to its biodegradability. Legal conditions in the European Union prohibit sewage sludge storage. Therefore, there is a need to develop thermal methods for sewage sludge treatment. The most common way to date has been combustion. However, this process has a lot of disadvantages associated primarily with environmental harmfulness and the immediate need to use the heat produced. Pyrolysis and gasification are considered the most promising methods of sludge management. They have many advantages over combustion. However, it is difficult to tell which method is more likely to be widely used. Therefore, the paper presents a critical comparison of the solar pyrolysis process and gasification in the fixed bed of municipal sewage sludge. The analysis of the process parameters and combustible properties of the gaseous fuels obtained was analysed.
Osady ściekowe są uważane za biomasę ze względu na swą biodegradowalność. Warunki prawne w Unii Europejskiej zabraniają składowania osadów ściekowych, dlatego istnieje potrzeba rozwoju termicznych metod wykorzystania osadów ściekowych. Dotychczas najczęstszym sposobem jest spalanie. Proces ten ma jednak wiele wad związanych przede wszystkim ze szkodliwością dla środowiska i natychmiastową potrzebą wykorzystania wytworzonego ciepła. Piroliza i zgazowanie są uważane za najbardziej obiecujące metody zagospodarowania osadów. Mają wiele zalet w porównaniu do spalania. Trudno jednak stwierdzić, która metoda będzie częściej stosowana, dlatego w artykule przedstawiono porównanie procesu pirolizy słonecznej i zgazowania w złożu nieruchomym komunalnego osadu ściekowego. Przeanalizowano wpływ parametrów procesu na właściwości palne otrzymanych gazów procesowych.
Źródło:
Proceedings of ECOpole; 2020, 14, 1; 39-46
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy analysis of the PV farm with a capacity of 140 MW
Autorzy:
Walichnowska, Patrycja
Idzikowski, Adam
Powiązania:
https://bibliotekanauki.pl/articles/34670814.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
photovoltaic
renewable source of energy
solar farm
energy
fotowoltaika
odnawialne źródła energii
farma słoneczna
energia
Opis:
Recently, there has been a large development of photovoltaics in Poland and in the world. This work shows how the energy profit of a high-power photovoltaic farm changes with the change of the angle of inclination of the panels on the example of a PV power plant project in the Siemiatycze districtin the Podlaskie Voivodeship. In order to verify the energy gain, measurements were made in the PVSyst program for panels with a power of 600 Wp, the spacing of 10 m or 6 m for angles from 20° to 25°. Based on the analysis, the results were obtained, which indicate that with an increase in the angle of inclination in the studied range of angles, the annual production of energy by power plants increases. The difference between the production for the angle of 20° and the angle of 25° is 1010 MWh, which means profits higher by almost 1% per year. on the basis of the selected row spacing and angle, an analysis was carried out, which shows that the average amount of energy generated in a 140 MW installation will be approximately 149 246 MWh. The article also contains an analysis of losses which are generated during the work of PV panels.
Źródło:
Quality Production Improvement - QPI; 2021, 3, 1; 369-376
2657-8603
Pojawia się w:
Quality Production Improvement - QPI
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies