Wyszukujesz frazę "smoke detectors" wg kryterium: Wszystkie pola


Wyświetlanie 1-13 z 13
Tytuł:
Reducing the Multi-Sensor Smoke Detectors Susceptibility to False Triggering
Ograniczenie podatności wielodetektorowych czujek pożarowych na mylne wzbudzenia
Autorzy:
Szafarczyk, Kalina
Powiązania:
https://bibliotekanauki.pl/articles/34670981.pdf
Data publikacji:
2022
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire detector
false alarms
detector operating modes
reduction of false triggering of fire detectors
czujka pożarowa
fałszywe alarmy
tryby pracy czujki
ograniczenie mylnych wzbudzeń czujek pożarowych
Opis:
Purpose: An assessment of the possibility of reducing the susceptibility of fire detectors to false alarms was carried out by: 1) analysing the impact of changing the operating modes of a multi-sensor detector on minimizing false alarms, and 2) verifying, using ANOVA tests, two hypotheses: either the settings or the sensitivity of the sensor affect the susceptibility of the detectors to false alarms. Project and methods: In order to assess the impact of false alarms on the operation of facilities equipped with a Fire Alarm System, a survey was conducted, directed at their administrators. A study of the fire detectors susceptibility to false alarms included placing the DTC-6046 multi-sensor detector in a closed test chamber and initiating the detector’s triggering by a deceptive agent. It was then observed whether the detector would initiate a fire alarm depending on different operating mode settings. The operation of the sensors was changed to interdependent, independent or coincidence work. Sensitivity settings of the sensors were changed from normal to increased by 20%, decreased by 20% or by 40%. An analysis using ANOVA test was conducted to verify which settings have a significant impact on minimising false alarms. Based on the results, example configuration guidelines were developed. Results: Based on the study, the following main results were formulated. The configuration least prone to false triggering is the one in which the sensors operate interdependently and the sensitivity is reduced by 40%. The highest number of false alarms was observed when sensitivity was increased by 20% with independent sensors and in coincidence, as well as for independent sensors working at normal sensitivity. Performing verification using ANOVA analysis of variance, the hypothesis that sensor settings have a statistically significant effect on minimising false alarms was rejected. Conclusions: There is a need to search for and implement ways to minimise false alarms of Fire Alarm Systems. The most common reason for false triggering of fire detectors are external factors that are not fire hazards (e.g. dust, dirt). The way of minimising false alarms is a proper setting of the detector operating modes (not often used in practice). The operating modes are based on changing the settings of sensor cooperation and detector sensitivity, where changing only the settings of the sensors does not result in such significant changes as changing the sensitivity of the detectors to increased or decreased compared to normal (result of ANOVA analysis).
Cel: Ocena możliwości ograniczania podatności czujek pożarowych na mylne wzbudzenia wykonana na podstawie: 1) analizy wpływu zmiany trybów pracy czujki wielodetektorowej na minimalizację fałszywych alarmów oraz 2) weryfikacji przy wykorzystaniu testów ANOVA dwóch hipotez: nastawy albo czułość sensorów wpływają na podatność czujek na mylne wzbudzenia. Projekt i metody: Aby ocenić wpływ fałszywych alarmów na funkcjonowanie obiektów, przeprowadzono ankietę, skierowaną do administratorów obiektów wyposażonych w system sygnalizacji pożarowej. Badania laboratoryjne podatności czujek pożarowych na mylne wzbudzenia polegały na umieszczeniu czujki wielodetektorowej DTC-6046 w zamkniętej komorze badawczej i próbie wzbudzenia jej czynnikiem zwodniczym. Obserwowano, czy czujka zainicjuje alarm pożarowy w zależności od różnych ustawień trybów pracy. Zmieniane były parametry określające pracę sensorów (współzależnie, niezależnie, w koincydencji) oraz ustawienia ich czułości z normalnej na podwyższoną o 20%, obniżoną o 20% bądź 40%. Przebadano 12 konfiguracji. Wyniki poddano analizie statystycznej metodą ANOVA, która pozwoliła na weryfikację, które ustawienia wpływają znacząco na minimalizację fałszywych alarmów. Na tej podstawie opracowane zostały przykładowe wytyczne konfiguracji. Wyniki: Na podstawie przeprowadzonych badań sformułowano poniższe główne ich wyniki. Najmniej podatna na fałszywe zadziałania jest konfiguracja, w której sensory działają współzależnie, a czułość jest obniżona o 40%. Najwyższą liczbą fałszywych alarmów charakteryzują się ustawienia czułości podwyższonej o 20% w przypadku sensorów niezależnych oraz będących w koincydencji, jak i dla sensorów niezależnych zadziałanie przy czułości normalnej. Przeprowadzenie weryfikacji, wykorzystując analizę wariancji ANOVA, pozwoliło odrzucić hipotezę, jakoby nastawy sensorów w istotnie statystyczny sposób wpływały na minimalizację fałszywych alarmów. Wnioski: Występuje konieczność poszukiwania i wdrażania sposobów minimalizowania fałszywych alarmów SSP. Najczęstszym powodem mylnego wzbudzania czujek pożarowych są czynniki zewnętrzne, niebędące zagrożeniem pożarowym (np. pył, kurz). Sposobem na ograniczenie tego zjawiska jest właściwe ustawienie trybów pracy czujki (stosowane w praktyce niezbyt często). Tryby pracy opierają się na zmianie ustawień współpracy sensorów oraz czułości czujki, gdzie zmiana tylko ustawień sensorów nie powoduje tak znaczących zmian, jak zmiana czułości czujek na podwyższoną bądź obniżoną w stosunku do normalnej (wynik analizy ANOVA).
Źródło:
Safety and Fire Technology; 2022, 60, 2; 164-174
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czujki dymu wykorzystujące światło rozproszone do pomiaru gęstości optycznej dymu
Smoke Detectors Using Diffused Light to Measure Smoke Optical Density
Autorzy:
Kustra, P.
Powiązania:
https://bibliotekanauki.pl/articles/136866.pdf
Data publikacji:
2009
Wydawca:
Szkoła Główna Służby Pożarniczej
Opis:
Artykuł zawiera informacje dotyczące wybranych elementów teorii rozpraszania światła, na podstawie której przedstawiona została budowa i zasada działania różnych czujek dymu wykorzystujących zjawisko rozpraszania światła.
The first part of the article describes elements concerning the theory of diffused light. The next part introduces structure and use of conventional smoke detector. Then the structure of smoke detectors measurement chamber has been presented. Those smoke detectors have bigger detection power than the conventional ones. The paper last part describes the structure and activity of a smoke detector of the biggest possible to reach level of detection. While using it we can even detect single particles of smoke.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2009, 38; 29-46
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ prędkości przepływu powietrza na czas zadziałania czujek zasysających dymu
Impact of Air Flow Velocity on Response Time of Smoke Detectors
Autorzy:
Wnęk, W.
Dubicki, J.
Mostowik, N.
Powiązania:
https://bibliotekanauki.pl/articles/136629.pdf
Data publikacji:
2016
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
system sygnalizacji pożarowej
czujki działające z wykorzystaniem światła rozproszonego
czujki działające z wykorzystaniem światła przechodzącego lub jonizacji
czujki zasysające
cząstki dymu
fire detection and fire alarm system
detectors using scattered light
detectors using transmitted light or ionization
aspirating smoke detectors
smoke particles
Opis:
W artykule podjęto się analizy wpływu przepływu powietrza na czas zadziałania czujek zasysających dymu. Omówiono stanowisko pomiarowe wykonane na podstawie norm do badania czujek pożarowych dymu. Zbadano wpływ prędkości przepływu mieszaniny powietrzno-dymowej na rozkład cząstek dymu. Dokonano porównania wpływu prędkości przepływu na czas zadziałania czujek jonizacyjnych, optycznych rozpraszających do czujek zasysających. Badania wykonano dla spalania płomieniowego i bezpłomieniowego. Sformułowano wnioski mające wpływ na proces projektowania systemów zabezpieczeń.
The paper contains an analysis of impact of air flow velocity on response time of aspirating smoke detectors. A measurement appliance, constructed on the basis of standards for fire smoke sensors testing, has been described. The impact of flow velocity of air and smoke mixture on the smoke particles distribution was tested. A comparison of impact of flow velocity on the response time of dispersion optical, ionization detectors and aspirating smoke detectors was performed. The research was performed for flame and flameless combustion. The conclusions , having impact on the protection systems design, were formulated.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2016, 3, 59; 5-19
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Increase of noise immunity of laser smoke fire detectors
Autorzy:
Kitsak, A.
Esipovich, D.
Poliakov, V.
Powiązania:
https://bibliotekanauki.pl/articles/136356.pdf
Data publikacji:
2011
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
noise immunity
laser radiation
external interference
differential scheme of smoke particles registration
Opis:
The article describes of the optical system of the proposed smoke detector construction, in which lightening of a smoke chamber is made by a focused laser beam having, according to the periodic law, a modulated spatial distribution of radiation intensity in the focal spot. This structure of the light field in the smoke flow allows to generate the algorithm of signals selection produced by the smoke particles with characteristic sizes and velocities. The result is increased stability of the smoke detector under the influence of external noise such as dust, vapor with different sizes of smoke particles and/or velocities. There are carried out model experiments on registration of time signals that are generated by particles of different sizes, crossing the plane of the beam focusing. The spectral characteristics of the recorded signals are researched. There are identificated possible algorithms for selection of signals generated by micro formations with specified medium size and speed of movement.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2011, 42; 123-126
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ rodzaju drewna na czas działania liniowych czujek dymu
The Influence of Wood Type on the Response Time of Optical Beam Smoke Detectors
Autorzy:
Porowski, R.
Janik, N.
Wdowiak, T.
Wnęk, W.
Powiązania:
https://bibliotekanauki.pl/articles/373335.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
czujki liniowe dymu
spalanie drewna
detekcja pożaru
optical beam smoke detectors
wood combustion
fire detection
Opis:
Cel: Celem artykułu jest przeprowadzenie badań doświadczalnych dla dwóch wybranych liniowych czujek dymu, czujki OSID oraz DOP 6001 w zakresie czasów zadziałania w zależności od rodzaju spalanego drewna oraz spalania bezpłomieniowego i płomieniowego. Wprowadzenie: Na przestrzeni lat opracowano wiele typów czujek pożarowych różniących się zasadą działania. Najprostsze z nich to nieskomplikowane czujniki temperatury, najpierw mechaniczne, później, wraz z rozwojem techniki elektroniczne. Zdawano sobie sprawę, że nie wykrywają one zagrożenia dostatecznie szybko, dlatego też poszukiwano rozwiązań, które reagowałyby na pierwsze oznaki rozwijającego się pożaru. Punktowe czujki dymu są łatwe w montażu i obsłudze, gdyż są kompletnym, samowystarczalnym urządzeniem. Ich skuteczność maleje wraz z oddalaniem się źródła dymu od miejsca montażu czujki. W niektórych budynkach, jak np. duże hale magazynowe czy fabryki, dla zachowania odpowiedniego stopnia ochrony należałoby instalować setki czujek punktowych, aby ich zasięg skutecznego działania pokrył całą powierzchnię pomieszczenia. W takiej sytuacji lepszym rozwiązaniem są optyczne liniowe czujki dymu, które w zależności od gęstości ich instalacji, mogą pod względem powierzchni dozorowej zastąpić nawet 20 czujek punktowych. Metodologia: Artykuł został opracowany na podstawie przeprowadzonych badań doświadczalnych w komorze badawczej, przy wykorzystaniu różnych źródeł spalania bezpłomieniowego i płomieniowego. Wnioski: W próbach ze spalaniem bezpłomieniowym dym zaczynał się wydzielać niezwłocznie po umieszczeniu drewna na płycie grzewczej, proces tlenia się drewna był jednostajny. Przebieg parametrów pracy czujek w czasie jest w dużym przybliżeniu liniowy, co oznacza jednostajne tempo zmniejszania się przezroczystości powietrza w komorze badawczej. Spalanie płomieniowe rozpoczyna się od małego płomienia podpalonego alkoholu, który musi zainicjować spalanie drewna. Szybkość spalania, a co za tym idzie ilość wydzielanego dymu, cały czas rośnie, co powoduje zbliżony do wykładniczego przebieg parametrów pracy czujek w czasie. Tłumienie wiązek światła wysyłanych przez nadajnik czujki OSID, przebiega różnie, w zależności od typu spalania. Dym pochodzący ze spalania bezpłomieniowego początkowo tłumi obie wiązki jednakowo, dopiero po czasie pojawia się różnica pomiędzy tłumieniem UV a IR. Podczas spalania płomieniowego różnica jest widoczna natychmiast i wyraźnie powiększa się wraz z rozwojem pożaru testowego.
Aim: The aim of this paper is to carry out an experimental test of the influence of wooden materials on the activation time of two types of optical beam smoke detectors – the OSID and the DOP 6001 – during flaming and non-flaming combustion. Introduction: Over the years, there have been many types of fire detector that differ in the way they operate. A few years ago, it was discovered that many detector types depended on the operation principle. The simplest detectors were temperature detectors, at first mechanical, and then, with the development of technology, also electronic. It was obvious that they did not detect the threat fast enough, so it was essential to find solutions that would respond to the first signs of a developing fire. Spot-type smoke detectors are easy to install and use because they are a complete, self-contained devices. Their effectiveness decreases as the distance between the source of combustion and the location of smoke detectors grows. In some buildings, e.g. large warehouses or industrial plants, for a better fire-safety level, there is a need to install dozens of spot-type smoke detectors to protect large areas. In such cases optical beam smoke detectors could be the best practical solution. Methodology: The article is based on a series of experimental tests in a test chamber with various sources of flaming and non-flaming combustion. Two different types of optical beam smoke detectors were used to test the influence of wooden beams on activation times. Conclusions: During the experiments with non-flaming combustion, intense smoke production started immediately after the initiation of the combustion process. The non-flaming phenomenon was a very stable process for all kinds of tested wood. The activation-time results of optical beam smoke detectors and the evolution of the operational parameters, which was almost linear, indicate that these types of detectors are more effective for non-flaming combustion, as opposed to flaming combustion. Flaming combustion starts with a small flame of burning alcohol, which can initiate the combustion of wood. The burning rate and the intensity of smoke production increased, causing a linear evolution of operation parameters from tested smoke detectors over time. The suppression of light beams emitted by the transmitter of the OSID detectors shows different evolution depending on the type of combustion. Smoke production from non-flaming combustion initially suppresses both light beams. After some delay, the effect of the differences between UV and IR suppression is observed. During flaming combustion, the difference is immediately apparent and clearly increases with the development of the test fire.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 44, 4; 67-82
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Economic justification for the new approach of using videobased smoke detection with the aim of decreasing total costs incurred by the untimely detection of fires on ships
Autorzy:
Bistrović, M.
Ristov, P.
Powiązania:
https://bibliotekanauki.pl/articles/135234.pdf
Data publikacji:
2017
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
fire alarm
video technology
computer vision
video detection
smoke detectors
ships
Opis:
Although various methods of using new techniques and technologies in ship fire alarm systems have been developed to date, some of which have made significant improvements in the functioning of such systems, in practice there is still plenty of room for further research regarding the operational efficiency of ship fire alarm systems and its impact on crew, passenger and overall ship safety. The application of electronic and computer technologies enables the development of intelligent solutions to improve the efficiency of ship fire alarm systems. Besides the economic justification, this paper presents a comparative analysis of classical and modern approaches based on video detection and computer vision in the detection of early phase smoke as a precursor to fire incidents. The economic justification of the new approach is concerned with decreasing the costs incurred by the untimely detection of the early stages of fire in ship engine rooms.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2017, 51 (123); 21-27
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu gęstości drewna ulegającego spalaniu na czas zadziałania czujek dymu
Autorzy:
Popielarczyk, T.
Powiązania:
https://bibliotekanauki.pl/articles/372798.pdf
Data publikacji:
2009
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
czujka dymu
gęstość drewna
pożar
spalanie
combustion
fire
smoke detectors
wood density
Opis:
Artykuł przedstawia opis i wyniki badania dotyczącego wpływu gęstości drewna na właściwości detekcyjne czujek dymu.
This article presents description and results of test relating influence of wood density on properties detection of smoke detectors.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2009, 2; 51-63
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja modelowego systemu do badań osłon przeciwwietrznych z czujkami dymu
The concept of the model system for testing the anti-wind covers with the smoke detectors
Autorzy:
Samborski, T.
Kozioł, S.
Zbrowski, A.
Stępień, P.
Powiązania:
https://bibliotekanauki.pl/articles/256457.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
bezpieczeństwo techniczne
system badań
osłona przeciwwietrzna
czujka dymu
technical safety
testing system
anti-wind cover
smoke detector
Opis:
W artykule zaprezentowano koncepcję modelowego systemu do badań osłon przeciwwietrznych z czujkami dymu stosowanych w zabezpieczeniach czynnych poprawiających poziom bezpieczeństwa przeciwpożarowego. Przedstawiono problemy związane z nieprawidłowym funkcjonowaniem układów wykrywania dymu w kanałach wentylacyjnych. Opisano procedury badań osłon przeciwwietrznych, jakim muszą podlegać w celu uzyskania certyfikatu dopuszczającego do zastosowania w systemach ppoż. Zaprezentowano koncepcję budowy stanowiska badawczego składającego się z testowego kanału wentylacyjnego z uniwersalną komorą do montażu osłon przeciwwietrznych wyposażonego w system kontrolno-pomiarowy odpowiedzialny za realizację opracowanych procedur badawczych.
The article presents the concept of the model system for testing the anti-wind covers with smoke detectors used in active protection devices adding to the fire protection. The issues related to incorrect functioning of the smoke detectors in the ventilation systems were discussed. The testing procedures are described to which the anti-wind covers are subjected in order to gain relevant certificates. The article presents the concept of the construction of the test stand consisting of test ventilation duct with universal chamber for fixing of the anti-wind covers equipped with the control-measurement system responsible for performing of the described testing procedures.
Źródło:
Problemy Eksploatacji; 2012, 1; 87-97
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Povyšenie èffektivnosti raboty sovremennyh točečnyh optičeskih dymovyh izveŝatelej
Improvement in the Operating Effectiveness of Modern Optical Point Smoke Detectors
Zwiększenie skuteczności pracy nowoczesnych optycznych punktowych czujek dymu
Autorzy:
Kitsak, A. I.
Lushchik, A. P.
Yesipovich, D. L.
Kaval'chuk, I. V.
Powiązania:
https://bibliotekanauki.pl/articles/373121.pdf
Data publikacji:
2014
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
optical point smoke detector
linear smoke detector
laser source
smoke
sensitivity
emission
punktowa czujka dymu
liniowa czujka dymu
źródło laserowe
dym
czułość
skupianie promieniowania
Opis:
Aim: Optical point smoke detectors have a number of significant drawbacks. The foremost are: dependence on the sensitivity of average smoke particle size, of different smoke variety, detection of the smoke emission path, dispersed by given particles, and reaction lead time, determined by the speed of convective air flow and design characteristics of the smoke detector chamber. These drawbacks are absent in linear optical smoke detectors, where the reaction to a fire is determined by the control of flow intensity of transmitted rays (non-dispersed) from smoke emissions. The purpose of this research is to improve the optical design of laser smoke detectors by exploiting traditional fire detection methods (intensity level of rays dispersed by smoke particles), and techniques used by linear smoke detectors. Methods: The project aim is realized with the aid of mathematical techniques and experimental modeling of energy transfer processes, by recording light beam expansion in an optically disparate environment, using aerosol smoke. Results: A two-channel laser smoke detector model was produced and tested for effectives. The main focus of tests was on the sensor’s sensitivity threshold. Tests were conducted in a flow through smoke chamber, with transverse dimensions of 500-500 mm2. The optical smoke density in the channel was controlled by a smoke control block. Sawdust was applied to create smoke. The lowest average unit value of optical smoke density during tests revealed a stable deviation for measured signals in both channels of the sensor. During an absence of smoke the value was identified as 0.11 dB/m. The optical smoke density measurements in the testing chamber, for dispersed ray emissions of the test model, revealed a reading of 0.065 dB/m.. Conclusions: Sensitivity research results for the enhanced laser smoke detector confirmed the potential for improving reliability, by increasing the proportion of detected emissions dispersed at small angles. The special structure of the detector light beam allows for the creation of an effective algorithm used for processing of registered signals, thus improving the sensor’s resistance to noise interference.
Cel: Punktowe optyczne czujki dymu, jak wiadomo, mają wiele istotnych wad. Główne z nich to: 1) zależność czułości od średnich rozmiarów cząsteczek różnorodnych dymów i kierunku rejestrowania promieniowania, rozproszonego przez dane cząsteczki; 2) zależność czasu reakcji od prędkości strumieni konwekcyjnych powietrza i właściwości konstrukcyjnych komory dymowej czujki. Wymienione niedoskonałości nie dotyczą liniowych optycznych czujek dymu, których reakcja na rozgorzenie pożaru polega na kontroli intensywności przechodzącego (nierozproszonego) przez dym promieniowania. Celem pracy jest udoskonalenie optycznego schematu laserowej punktowej czujki dymu, pozwalającego na jednoczesne zastosowanie tradycyjnej metody wykrywania pożaru charakterystycznej dla czujek tego typu (stopień intensywności promieniowania rozproszonego przez cząsteczki dymu) oraz metody stosowanej w liniowych czujkach dymu. Projekt i metody: Aby zrealizować ten cel, wykorzystano metodę matematycznego i eksperymentalnego modelowania procesu przenoszenia i rejestrowania wiązek świetlnych poprzez optycznie niejednorodne środowisko typu aerozol dymowy. Wyniki: Przygotowano model punktowej dwukanałowej laserowej czujki dymu, na którym przeprowadzono badanie jej skuteczności. Podstawową badaną cechą modelu czujki była jej czułość progowa. Badania prowadzono w dymowej komorze przepływowej o rozmiarach poprzecznych 500 x 500 mm2. Optyczna gęstość dymu w komorze była kontrolowana przez blok kontroli zadymienia. Do wytworzenia dymu zastosowano trociny. Najmniejsza średnia wartość jednostkowej optycznej gęstości dymu w komorze badawczej, przy której odnotowano stabilne odchylenie wartości sygnałów mierzonych w obu kanałach modelu czujki od ich średnich wartości przy braku dymu, wyniosła 0,11 dB/m. Przy tym optyczna gęstość dymu mierzona w kanale rejestrowania rozproszonego promieniowania modelu czujki wyniosła 0,065 dB/m. Wnioski: Wyniki badania czułości udoskonalonego modelu laserowej dymowej czujki świadczą o możliwości poprawienia jej niezawodności poprzez zwiększenie udziału rejestrowanego promieniowania rozproszonego na małe kąty. Specjalna struktura wiązki świetlnej w czujce pozwala na sformułowanie skutecznego algorytmu przetwarzania rejestrowanych sygnałów w celu poprawy odporności czujki na zakłócenia.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2014, 4; 125-130
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Role of Smoke Detectors and Carbon Monoxide Detectors in the Fire Safety of Residential Buildings
Rola czujek dymu i czujek tlenku węgla w bezpieczeństwie pożarowym obiektów mieszkalnych
Autorzy:
Garlińska, Urszula
Iwańska, Marta
Śliwiński, Robert
Florek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2060756.pdf
Data publikacji:
2021
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
Integrated Qualifications System
smoke
alarm
detector
electrical apparatus
detection
carbon monoxide
residential buildings
Zintegrowany System Kwalifikacji
ZSK
czujka
dym
tlenek węgla
czad
obiekt mieszkalny
Opis:
Purpose: The aim of this publication is to present the most important aspects of using smoke and carbon monoxide detectors intended for households or similar residential facilities as well as to indicate the advantages and disadvantages of the adopted system solutions that affect the number of detectors installed in this kind of buildings. The article aims to present the issues related to the Integrated Qualifications System (ZSK), i.e. newly developed market qualification, dedicated to installers and maintenance technicians of smoke and carbon monoxide detectors. Introduction: Smoke and carbon monoxide detectors for early detection of existing threats such as fires or escaping carbon monoxide are an important element of fire protection, dedicated primarily to owners of residential buildings. In many countries in the EU it is obligatory to install detectors in homes, whereas at the moment in Poland the only aspect regulated legally is the obligation of the manufacturer of these products to obtain a certificate. Since 2016, the ZSK has been operating in Poland, in which in 2019 the qualifications of installers/maintenance technicians of smoke and carbon monoxide detectors were distinguished. As a result, a person with a market qualification certificate is prepared for independent installation and maintenance of fire safety monitoring devices Methodology: As part of the research process, theoretical research was used, such as: analysis of literature and legal documents, synthesis, generalization, inference, comparison and analogy. As part of the research, documents from such countries as Poland, Great Britain (mainly England), Germany and France were analysed. The selection of individual countries was guided by the level of development of these systems in a given country and the availability of source documents Conclusions: The presented analysis of the requirements for the installation of the smoke and carbon monoxide detectors shows how different the approach is regarding the use of this type of devices. Depending on experiences and the administrative structure of a given country, a variety of regulations, whether legal or normative, can be discerned in the use of smoke and carbon monoxide detectors. ZSK is a well-described system of formal organization and classification of competences and offers the public services at the highest possible quality level. It is also a partial solution to the problem of installing detectors. However, it is necessary to regulate this issue from the legal level, as it was the case in other EU countries, where the installation of detectors in homes is obligatory. Such action will contribute to reducing the victims of fires or inhalation of toxic gases (carbon monoxide).
Cel: Celem niniejszej publikacji jest przedstawienie najważniejszych aspektów stosowania czujek dymu i czujek tlenku węgla w prywatnych obiektach mieszkalnych, a także wskazanie zalet oraz wad przyjętych rozwiązań systemowych, które mają wpływ na liczbę detektorów montowanych w tego typu obiektach. Artykuł przedstawia również zagadnienia związane z Zintegrowanym Systemem Kwalifikacji (ZSK), tj. opracowanej kwalifikacji rynkowej, dedykowanej monterom i konserwatorom czujek dymu i czujek tlenku węgla. Wprowadzenie: Czujki dymu i czujki tlenku węgla to ważny element zabezpieczeń obiektów mieszkalnych. Dedykowane są one wszystkim właścicielom tych obiektów. W wielu krajach UE obligatoryjne jest montowanie czujek w domach, natomiast obecnie w Polsce wymagane jest jedynie ich certyfikowanie przez producenta. Od 2016 roku w Polsce funkcjonuje ZSK, w którym w roku 2019 wyodrębniono kwalifikacje dla monterów/konserwatorów czujek dymu i czujek tlenku węgla. Dzięki temu osoba posiadająca certyfikat kwalifikacji rynkowej jest przygotowana do samodzielnego montażu i konserwacji urządzeń monitorujących bezpieczeństwo pożarowe. Metodologia: W ramach procesu badawczego wykorzystano badania teoretyczne, takie jak: analiza literatury i dokumentów prawnych, synteza, uogólnianie, wnioskowanie, porównanie oraz analogia. Podczas badań dokonano analizy dokumentów z Polski, Wielkiej Brytanii (głównie Anglii), Niemiec i Francji. Przy ich doborze kierowano się poziomem rozwoju tych systemów w danym kraju oraz dostępnością dokumentów źródłowych. Wnioski: Przedstawiona analiza wymagań w zakresie obowiązku instalacji czujek dymu i czujek tlenku węgla pokazuje, jak różne jest podejście do ich stosowania w Polsce i w wybranych państwach europejskich. W zależności od doświadczeń oraz struktury administracyjnej danego kraju można dostrzec różnorodność przepisów prawnych czy normatywnych. ZSK jest opisanym systemem formalnego uporządkowania i klasyfikacji kompetencji i oferuje społeczeństwu usługi na możliwie najwyższym poziomie jakościowym. Niezbędne jest prawne uregulowanie tej kwestii, tak jak zostało to zrobione w innych krajach UE, gdzie instalacja czujek w domach jest obowiązkowa. Takie działanie przyczyni się do zredukowania ofiar pożarów lub zaczadzeń.
Źródło:
Safety and Fire Technology; 2021, 57, 1; 114--133
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ pyłów pochodzenia drzewnego na działanie czujek pożarowych dymu
Influence of Wooden-Based Dusts on Smoke Fire Detectors
Autorzy:
Wnęk, W.
Jargieło, M.
Porowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/373369.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
systemy sygnalizacji pożarowej
czujki dymu
fałszywe alarmy
pył drzewny
fire detection systems
smoke detectors
false alarms
wooden dust
Opis:
Cel: Obecnie poszukuje się rozwiązań w zakresie czujek pożarowych dymu, które nie będą wrażliwe na sygnały zwodnicze powodujące fałszywe alarmy pożarowe central sygnalizacji pożarowej. Jednym z takich sygnałów jest występujący w pomieszczeniach pył drzewny traktowany przez czujkę jako dym o dużych cząstkach. W artykule opisano wykonane badania wybranych czujek dymu dla różnych pyłów drzewnych. Celem podstawowym artykułu jest wybór najbardziej odpornej czujki dymu na cząstki pyłu, bez pogorszenia jej właściwości detekcyjnych. Wprowadzenie: Podczas projektowania instalacji systemów sygnalizacji pożarowej napotyka się na problemy doboru czujek pożarowych pracujących w otoczeniu różnych zakłóceń powodujących fałszywe alarmy. Początkowo zbadano wpływ pyłu celulozowego wytwarzanego przy produkcji czasopism w jednej z drukarni. Następnie przeanalizowano również wpływ innych pyłów. Przy pomiarach mieszaniny cząstek o różnych wielkościach nie można jednoznacznie ocenić ich wpływu na sposób wykrywania. W związku z tym dokonano podziału pyłu ze względu na wielkość jego cząstek na pył o średnicach 100 μm, 200 μm i 500 μm. Pozwoliło to na zbadanie wpływu nie tylko rodzaju drewna, ale także wielkości cząstek pyłu na zadziałanie czujek. Metodologia: W trakcie badań opracowano metodę pomiaru wpływu pyłu na zadziałanie czujek. Dobrano ciśnienie sprężonego powietrza na poziomie 1,5 bar wraz z czasem otwarcia zaworu butli ze sprężonym powietrzem tak, aby osiągnąć najlepsze rozprowadzenie pyłu w pomieszczeniu badawczym. Za krótki czas otwarcia zaworu powodował pozostawanie pyłu w pojemniku, za długi powodował natomiast rozdmuchiwanie obłoku pyłu. W kilku próbach jako optymalny czas przyjęto 3 s. Czujki umieszczono umieszczono pryzmatycznie na przeciwległych ściankach pod sufitem komory w układzie nadajnik-odbiornik, nadajnik-lusterko. Wyniki pomiarów były rejestrowane za pomocą układu komputerowego. Wnioski: W wyniku przeprowadzonych badań, z uwzględnieniem zachowania czujek pożarowych dymu, określono rozwiązanie konstrukcyjne w postaci czujki systemu OSID jako czujki, która najlepiej poradziła sobie z pyłem występującym w zabezpieczanych pomieszczeniach. Jest to spowodowane sposobem obróbki sygnału w czujce. Na zadziałanie miały wpływ wielkość pyłów oraz, w mniejszym stopniu, rodzaj pyłu w odniesieniu do gatunku badanego drewna.
Aim: There is a need of fire detection solutions which are sensitive to deceptive signals. They can lead to false fire alarms. One of such signals is the activation of detectors in case of wooden dusts accumulated in the protected area which is regarded by the detector as smoke with large particles. This paper describes selected experimental results on various detectors and different wooden dusts. The aim of this project is to select a detector that is highly resistant to dust particles. Introduction: During designing fire detection systems there is always a problem in a proper selection of fire detectors operating in environments where there are various sources of false alarms. Initially, the influence of cellulose dusts as could be observed during the production of newspapers at the printing house was studied. Then the influence of other dusts was analyzed. During the measurement of smoke particles of different sizes the influence of particles on the detection cannot be explicitly determined. Due to this fact, tested dust was divided taking into consideration the size of the particles where the diameter was 100 μm, 200 μm and 500 μm. It made it possible to test the influence on the operation of the detectors of not only wooden-based materials but also of the size of dust particles. Methodology: During the tests the methodology of measuring the influence of dust on the activation time of detectors was prepared. The pressure of the compressed air was set at 1,5 bars together with the opening time of the valve of the compressed air container in order for the dust to be emitted evenly in the test chamber. If the valve opening time was too short, the dust remained in the container. If it was too long – the dust was blown all over the chamber. The optimum time was set as 3 s. Tested detectors were located by the ceiling of the chamber in the following manner: transmitter-receiver, transmitter-prismatic mirror on opposite walls. Measurement results were registered using a computer system. Conclusions: As a result of the conducted tests, which included the behaviour of fire detectors smoke, the best design solution was determined that best coped with duste present in protected areas. It is OSID smoke detection system. It is a result of how the signal was processed by the detector. The size of dust particles and, to a smaller degree, type of dust with respect to the tested species of wood influenced the operation of the smoke detector.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 42, 2; 43-55
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przegląd Technologii Przetwarzania Odpadów promieniotwórczych stosowanych przez ZUOP w Polsce
Overview of radioactive waste processing technologies used by the RWMP in Poland
Autorzy:
Żebrowski, Jakub
Powiązania:
https://bibliotekanauki.pl/articles/2055832.pdf
Data publikacji:
2021
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
odpady radioaktywne
izotopowe czujki dymu
technologie przetwarzania odpadów promieniotwórczych
klasyfikacja odpadów promieniotwórczych
radioactive waste
isotope smoke detectors
radioactive waste treatment
radioactive waste treatment technologies
classification of radioactive waste
Opis:
W artykule omówiono aktualnie stosowane technologie przetwarzania odpadów promieniotwórczych stałych oraz ciekłych, postępowanie z izotopowymi czujkami dymu, oraz promieniotwórczymi odpadami biologicznymi. Przedstawiono także historię Zakładu Unieszkodliwiania Odpadów Promieniotwórczych (ZUOP) oraz klasyfikację odpadów promieniotwórczych.
In this article the currently used treatment and conditioning technologies for solid and liquid radioactive waste, handling isotope smoke detectors and radioactive biological waste are presented. The history of the Radioactive Waste Management Plant and the classification of radioactive waste are also presented.
Źródło:
Postępy Techniki Jądrowej; 2021, 3; 15--22
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Primenenie lazernyh i optovolokonnyh tehnologij dlâ povyšeniâ èffektivnosti raboty sovremennyh optiče
The Application of Laser and Fibre-Optic Technologies for the Improvement of the Efficiency of Modern Optical Smoke Detectors
Zastosowanie technologii laserowych i światłowodowych w celu zwiększenia skuteczności pracy nowoczesnych optycznych czujek dymu
Autorzy:
Ivanov, Y. S.
Lushchik, A. P.
Kitsak, A. I.
Powiązania:
https://bibliotekanauki.pl/articles/373079.pdf
Data publikacji:
2018
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
dual fire sensor
point smoke detector
linear smoke detector
laser source
optical fibre
sensitivity
dualna czujka pożarowa
punktowa pożarowa czujka dymu
liniowa pożarowa czujka dymu
źródło laserowe
światłowód
wrażliwość
Opis:
Objective: The aim of the study is to demonstrate the possibility of increasing the sensitivity, resistance to electromagnetic interference and response speed of point smoke detectors on the basis of using laser processing and fibre optics technology. Project and methods: In order to achieve the above goal an optical point smoke detector was designed and produced. The detector uses a laser radiation source and fibre-optic communication line with a radiation receiver. Results: The combined laser-based fire alarm device which includes two smoke detection methods (controlling the intensity of radiation scattered by smoke particles and passed through the smoke without scattering) and carbon monoxide detector are produced. The tests of the fire detector to determine its basic functional parameters and the performance of detecting the test fire sources in accordance with standard SТB 16.03-2009. The minimum threshold quantity of optical smoke density detected in the control channel of the intensity of scattered radiation is 0.05 dB/m. The minimum threshold quantity of optical smoke density detected in the control channel of the intensity of radiation passing through the smoke without scattering is about 0.9 dB/m for controlled optical length 25 mm. The minimum concentration of carbon monoxide detection by the CO gas detector is 40 ppm. The testing results of combined laser-based fire alarm device on the detection efficiency of the standardised fire source bear record to its hypersensitivity for different types of smoke and a higher speed of detection of fires in comparison with single-channel point smoke detector. The tests of the combined laser fire detector to determine the efficiency of the fire detection model point to its increased sensitivity to different types of smoke and fire detection speed in comparison with a conventional single-channel point smoke detector. Using fibre optics for recording radiation getting through smoke without dissipation showed us the possibility of developing a point smoke detector on the linear principle of smoke detection with signal processing at a distance from the controlled zone in a well-screened box, for instance, inside a fire alarm control panel. Obviously, the signaling device will be highly resistant to electromagnetic interference due to the reliable screening of the sensitive elements of the electronic signal processing system and the lack of wiring connected to the fire alarm control panel. Conclusions: The advanced functional characteristics of the fire alarm device are provided thanks to the application of a laser source with a high intensity and a low divergence of radiation. The unique properties of laser radiation in the sensor’s structure made it possible to apply a number of design and technical solutions which provided a substantial increase in the sensitivity and fire detection rate of the sensor compared to the currently used traditional LED smoke detectors.
Cel: Celem pracy jest przedstawienie możliwości zwiększenia wrażliwości i odporności na interferencje elektromagnetyczne optycznych (punktowych) czujek dymu oraz poprawienia ich szybkości zadziałania poprzez zastosowanie technologii laserowych i światłowodowych. Projekt i metody: W celu osiągnięcia powyższego celu zaprojektowano i wyprodukowano optyczną punktową czujkę dymu wykorzystującą laserowe źródło promieniowania i połączenie światłowodowe z odbiornikiem promieniowania, a także przebadano jej charakterystyki użytkowe. Wyniki: Opracowano laserową czujkę dymu wykorzystującą dwie metody wykrywania dymu (kontrolę intensywności promieniowania rozproszonego cząsteczkami dymu oraz promieniowania przechodzącego przez dym bez rozproszenia) oraz czujnik tlenku węgla (CO). Przeprowadzono badania czujki mające na celu określenie jej podstawowych parametrów użytkowych oraz skuteczność wykrywania testowych źródeł pożaru zgodnie z normą STB 16.03-2009. Minimalna wartość progowa gęstości dymu wykrywana w komorze kontroli intensywności promieniowania rozproszonego wynosi 0,05 dB/m. Z kolei minimalna wartość progowa gęstości dymu w kanale kontroli intensywności promieniowania przechodzącego przez dym bez rozproszenia wynosi 0,9 dB/m przy kontrolowanej odległości 25 mm. Minimalne stężenie tlenku węgla, na które reaguje czujnik tlenku węgla to 40 ppm. Wyniki badań laserowej „łączonej” czujki pożarowej pod kątem skuteczności wykrywania przez nią testowych źródeł pożaru świadczą o jej zwiększonej wrażliwości na różne rodzaje dymu i szybszym wykrywaniu pożaru, w porównaniu ze standardową jednokanałową punktową czujką dymu. Zastosowanie światłowodów do rejestracji promieniowania przechodzącego przez dym bez rozproszenia wiązki pokazało, że możliwe jest opracowanie punktowej czujki dymu na jednej „liniowej” zasadzie wykrywania dymu i jednoczesne przetwarzanie sygnału w oddalonym od kontrolowanej strefy osłonionym bloku, na przykład wewnątrz centrali sygnalizacji pożarowej. Oczywiście, dzięki właściwej osłonie wrażliwych elementów układu elektronicznego przetwarzającego sygnał i rezygnacji z przewodów elektrycznych do połączeń z centralą, czujka tego typu będzie charakteryzowała się wysoką odpornością na zakłócenia elektromagnetyczne. Wnioski: Wysokie właściwości użytkowe czujki były możliwe do osiągnięcia dzięki zastosowaniu źródła laserowego o wysokiej intensywności i małej dywergencji promieniowania. Unikalne cechy promieniowania laserowego w konstrukcji czujki pozwoliły na zastosowanie wielu rozwiązań konstrukcyjnych i technicznych, które znacznie zwiększyły wrażliwość czujki i szybkość wykrycia pożaru w porównaniu z konwencjonalnymi diodowymi pożarowymi czujkami dymu.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2018, 49, 1; 86-92
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies