Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "resistance measurement" wg kryterium: Wszystkie pola


Tytuł:
An oxidation-resisitant measurement apparatus
Autorzy:
An, Dong-Yang
Dai, Jing-Min
Xiao, Peng
Powiązania:
https://bibliotekanauki.pl/articles/220362.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
coating
apparatus
oxidation resistance
wide temperature range
high precision
Opis:
On the basis of induction heating, radiation heating and liquid nitrogen refrigeration, high-temperature, medium-temperature, normal-temperature and low-temperature heating/refrigeration furnaces were designed, respectively. An apparatus with a wide temperature range and high accuracy applied to test oxidation resistance of materials has been developed based on the thermogravimetric method and the heat transfer principle. The apparatus consists of four heating/cooling systems, a specimen fixture positioning unit, a laser positioning unit, vertical and horizontal moving guide rails, and a high-precision weighing balance. The apparatus, based on the thermogravimetric method, is able to test oxidation resistance of materials. In the test, the temperature range was -180~3000°C (the highest temperature is determined by material properties). The temperature control accuracy was ±5°C. The accuracy of on-line weighing was ±0.1 mg. The measurement uncertainty was 0.2 mg. Compared with other relevant devices, this apparatus has its own advantages: simple operation, wide heating/cooling temperature range, sufficient specimen heating, high sensitivity and precision, and short heating/cooling time. The experimental results show that the developed apparatus presented in this study not only can be used for isothermal thermogravimetric tests, but also for thermal cycling tests and multi-step oxidation tests. With the effective integration of multiple heating apparatus and refrigeration apparatus, the apparatus breaks through the limitations of the heating/cooling temperature range of the existing devices, accomplishes the high-precision oxidation resistance test of materials in a wide temperature range, and will play a great role in improving the research of materials.
Źródło:
Metrology and Measurement Systems; 2019, 26, 4; 725-737
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the Lithuanian national standard of electric resistance
Autorzy:
Bartašiūnas, Andrius
Miškinis, Rimantas
Smirnov, Dmitrij
Urba, Emilis
Powiązania:
https://bibliotekanauki.pl/articles/1849159.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
measurement standards
electric resistance
standard resistor
calibration
uncertainty
prediction
Opis:
The Lithuanian national standard of electric resistance is maintained as the basis for calibration and measurement capabilities published in the key comparison database of the International Bureau of Weights and Measures (BIPM). The stability and uncertainty of the resistance value measurements, performed since 2004 using the calibrated values of the standard resistors to predict their future behaviour as well as influence of environmental conditions, are discussed. Also discussed is the recovery of a standard resistor which had undergone a mechanical disturbance. It is concluded that the standard resistors operated by the Lithuanian National Electrical Standards Laboratory feature stable drift of resistance, which is well predicted by means of linear regression.
Źródło:
Metrology and Measurement Systems; 2020, 27, 4; 615-624
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An automatic system for measurement of impedance active component using a quasi-balanced method
Autorzy:
Barwinek, S.
Cichy, A.
Powiązania:
https://bibliotekanauki.pl/articles/114468.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
virtual instruments
LabVIEW
capacitance measurement
impedance measurement
resistance measurement
phase shift measurement
Opis:
The paper presents the idea of the possibility of implementing automatic virtual instrument using the quasi ˗ balanced method to measure the active component of impedance (resistance). The system is based on the structure of a non-bridge quasi-balanced circuit. The process of balancing is automatically performed. This meter has been built based on the data acquisition board NI USB-6251 from National Instruments and programming environment LabVIEW. Signal processing is made in an algorithmic way. The measurement of the phase angle is based on short-term Fourier transform. The results of preliminary experimental research are presented in the paper.
Źródło:
Measurement Automation Monitoring; 2015, 61, 5; 132-135
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected performance indices for assessment of polypropylene susceptibility to dyeing by pigments of different UV resistance
Wybrane wskaźniki użytkowe oceny podatności polipropylenu na barwienie pigmentami o różnej odporności na UV
Autorzy:
Bieliński, Marek
Kościuszko, Artur
Smolińska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/1789755.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
dyeing of plastics
color measurement
injection molding
UV resistance
structure of materials
barwienie tworzyw
pomiar koloru
wtryskiwanie
odporność na UV
struktura tworzyw
Opis:
This study presents an assessment of the effects of usage time for polypropylene (PP) experimental samples including those dyed with pigments of different UV resistance. A standard double cavity mold was used to create the samples by injection molding. Selected indices were analyzed in terms of color change (UV resistance of pigments), and UV radiation resistance of a PP polymer medium. The experiment revealed a significant impact of the accepted usage time and the type of dye concentrates on the indices characterizing the sample color change (CIELab) and a change in the structure and state of the PP medium surface.
Oceniono wpływ czasu użytkowania próbek PP, w tym barwionych pigmentami o różnej odporności na UV, na wybrane wskaźniki użytkowe. Próbki doświadczalne wytworzono metodą wtryskiwania z zastosowaniem standardowej dwugniazdowej formy badawczej. Analizę wybranych wskaźników barwionych próbek przeprowadzono na podstawie: wyznaczonej zmiany barwy (odporność na UV pigmentów), a także odporności na promieniowanie UV nośnika polimerowego (PP). Wykazano istotny wpływ przyjętego w programie badań czasu użytkowania oraz rodzaju koncentratów barwiących na wartości wskaźników charakteryzujących barwę próbek (CIELab), a także strukturę i stan powierzchni tworzywa użytego jako nośnik (PP).
Źródło:
Polimery; 2021, 66, 1; 44--51
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Mechanical Properties of Gray Cast Iron Using Electrical Resistivity Measurement
Autorzy:
Bieroński, M.
Krasa, O.
Koza, M.
Książek, D.
Kuś, R.
Powiązania:
https://bibliotekanauki.pl/articles/380834.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
resistance
grey cast iron
tensile strength
NDT method
electrical resistivity
odporność
żeliwo szare
wytrzymałość na rozciąganie
metoda NDT
Opis:
In this paper an attempt to determine the relationship between the electrical resistivity and the tensile strength and hardness of cast iron of carbon equivalent in the range from 3.93% to 4.48%. Tests were performed on the gray cast iron for 12 different melts with different chemical composition. From one melt poured 6 samples. Based on the study of mechanical and electro-resistive determined variation characteristics of tensile strength, hardness and resistivity as a function of the carbon equivalent. Then, regression equations were developed as power functions describing the relationship between the resistivity of castings and their tensile strength and hardness. It was found a high level of regression equations to measuring points, particularly with regard to the relationship Rm=f(ρ). The obtained preliminary results indicate the possibility of application of the method of the resistance to rapid diagnostic casts on the production line, when we are dealing with repeatable production, in this case non variable geometry of the product for which it has been determinated before a regression equation.
Źródło:
Archives of Foundry Engineering; 2016, 16, 4; 29-32
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System do automatycznego pomiaru parametrów termicznych półprzewodnikowych przyrządów mocy
An automatic measurement system of thermal parameters of semiconductor power devices
Autorzy:
Bisewski, D.
Zarębski, J.
Powiązania:
https://bibliotekanauki.pl/articles/152727.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
parametry termiczne
rezystancja termiczna
przejściowa impedancja termiczna
półprzewodnikowe przyrządy mocy
thermal parameters
thermal resistance
transient thermal impedance
semiconductor power devices
Opis:
W pracy omówiono budowę i zasadę działania autorskiego systemu do automatycznego pomiaru parametrów termicznych, w tym czasowych przebiegów przejściowej impedancji termicznej oraz rezystancji termicznej półprzewodnikowych przyrządów mocy. W rozważanym systemie zaimplementowano popularną impulsową metodę pomiaru parametrów termicznych opartą na wykorzystaniu krzywej chłodzenia elementu półprzewodnikowego. Działanie systemu pomiarowego zilustrowano wynikami pomiarów parametrów termicznych wybranych półprzewodnikowych przyrządów mocy.
Generally, manufacturers of semiconductor devices do not provide in datasheets detailed information about thermal parameters of semiconductor devices, i.e. time waveform of junction-to-ambient transient thermal impedance or dependence of junction-to-ambient thermal resistance versus dissipated power. Therefore, the designers of electronic circuits do not have reliable information about thermal properties of semiconductor devices in the designed circuit [1 - 3]. The paper discusses the construction and operation of automatic measurement system of thermal parameters, including transient thermal impedance and thermal resistance of semiconductor power devices. Block diagram of the measurement system is shown in Fig. 1. In the measurement system, the popular Rubin and Oettinger [6] pulse method for measuring thermal parameters based on the cooling curve of semiconductor device, has been implemented. For reading and archiving the results of measurements, A/D and D/A converter USB-1608GX-2AO fabricated by Measurement Computing [5], has been used. Usefulness of the measuring system is illustrated by results of measurements of thermal parameters of silicon MOSFET (IRFR420A - International Rectifier), silicon carbide MESFET (CRF24010 - Cree) and silicon carbide Schottky diode (IDT06S60C - International Rectifier). As seen in Fig. 3, the thermal resistance junction-to-ambient strongly depends on semiconductor device dissipated power. For example, the thermal resistance of MOSFET decreases about 20% with increase of the dissipated power from 0.1 W to 1 W, at constant ambient temperature. It has been shown, that realization of such measurements allows to obtain more precise information about the thermal parameters of semiconductor devices in comparison to the device catalogue data.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 12, 12; 1150-1153
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wysokorezystywne wzorce do pomiaru profilu rezystywności krzemowych warstw epitaksjalnych metodą oporności rozpływu w styku punktowym
High resistivity standards for measurement of resistivity profile in silicon epitaxial layers by spreading resistance method
Autorzy:
Brzozowski, A.
Sarnecki, J.
Lipiński, D.
Wodzińska, H.
Powiązania:
https://bibliotekanauki.pl/articles/192377.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Materiałów Elektronicznych
Tematy:
rezystywność
oporność rozpływu
krzem monokrystaliczny
warstwa epitaksjalna
resistivity
spreading resistance
monocrystalline silicon
epitaxial layer
Opis:
Wykonano wzorce do kalibracji układu umożliwiającego wyznaczenie profilu rezystywności w krzemowych warstwach epitaksjalnych typu n i p o orientacji <111> i <100> z pomiarów rezystancji rozpływu styku punktowego (SR). Wykonane wzorce umożliwiają kalibrację systemu i zapewniają pomiar profilu rezystywności krzemowych warstw epitaksjalnych o rezystywności dochodzącej do 10 kΩcm. Wdrożono procedury zawarte w instrukcjach ASTM dla przeprowadzenia pomiarów metodą sondy czteroostrzowej rezystywności monokrystalicznych płytek krzemowych przeznaczonych na wzorce do kalibracji systemu SR.
Si standards for the calibration of a spreading resistance probe for measuring the resistivity profiles of n and p type <111> and <100> oriented silicon epitaxial wafers have been performed. These standards allow both the calibration of the SR system and the measurement of resistivity distribution in silicon epitaxial layers having resistivity of up to 10 kΩcm. Procedures for measuring the resistivity of silicon wafers used as standards for the SR systems calibration by the Four-Point Probe method have been implemented in accordance with the ASTM instruction.
Źródło:
Materiały Elektroniczne; 2013, T. 41, nr 4, 4; 20-26
0209-0058
Pojawia się w:
Materiały Elektroniczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methodology of heat transfer and flow resistance measurement for matrices of rotating regenerative heat exchangers
Autorzy:
Butrymowicz, D.
Karwacki, J.
Kwidziński, R.
Śmierciew, K.
Gagan, J.
Przybyliński, T.
Skiepko, T.
Łapin, M.
Powiązania:
https://bibliotekanauki.pl/articles/185740.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat transfer
single blow technique
rotating heat exchanger
regenerator
przenikania ciepła
wymiennik ciepła
Opis:
The theoretical basis for the indirect measurement approach of mean heat transfer coefficient for the packed bed based on the modified single blow technique was presented and discussed in the paper. The methodology of this measurement approach dedicated to the matrix of the rotating regenerative gas heater was discussed in detail. The testing stand consisted of a dedicated experimental tunnel with auxiliary equipment and a measurement system are presented. Selected experimental results are presented and discussed for selected types of matrices of regenerative air preheaters for the wide range of Reynolds number of gas. The agreement between the theoretically predicted and measured temperature profiles was demonstrated. The exemplary dimensionless relationships between Colburn heat transfer factor, Darcy flow resistance factor and Reynolds number were presented for the investigated matrices of the regenerative gas heater.
Źródło:
Chemical and Process Engineering; 2016, 37, 3; 341-358
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Implementation of a Compact Smart Resistive Sensor Based on a Microcontroller with an Internal ADC
Autorzy:
Czaja, Z.
Powiązania:
https://bibliotekanauki.pl/articles/221453.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
microcontrollers
resistance measurement
ADC
time-domain measurements
Opis:
In the paper a new implementation of a compact smart resistive sensor based on a microcontroller with internal ADCs is proposed and analysed. The solution is based only on a (already existing in the system) microcontroller and a simple sensor interface circuit working as a voltage divider consisting of a reference resistor and a resistive sensor connected in parallel with an interference suppression capacitor. The measurement method is based on stimulation of the sensor interface circuit by a single square voltage pulse and on sampling the resulting voltage on the resistive sensor. The proposed solution is illustrated by a complete application of the compact smart resistive sensor used for temperature measurements, based on an 8-bit ATxmega32A4 microcontroller with a 12-bit ADC and a Pt100 resistive sensor. The results of experimental research confirm that the compact smart resistive sensor has 1°C resolution of temperature measurement for the whole range of changes of measured temperatures.
Źródło:
Metrology and Measurement Systems; 2016, 23, 2; 225-238
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko do weryfikacji nowej metody pomiaru rezystancji pętli zwarciowej
Laboratory stand for testing of a new method of fault loop resistance measurement
Autorzy:
Czapp, S.
Borowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/268175.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
impedancja pętli zwarciowej
rezystancja pętli zwarciowej
wyłącznik różnicowoprądowy
stanowisko
laboratoryjne
fault loop impedance
fault loop resistance
residual current devices
laboratory stand
Opis:
W artykule przedstawiono budowę i zasadę działania stanowiska laboratoryjnego, które umożliwia weryfikację eksperymentalną nowej metody pomiaru rezystancji pętli zwarciowej. Metoda ta charakteryzuje się tym, że nie następuje wyzwalanie wyłączników różnicowoprądowych, mimo wykorzystania stosunkowo dużej wartości prądu pomiarowego. Weryfikacja metody na stanowisku laboratoryjnym jest podstawą do skonstruowania prototypowego miernika rezystancji pętli zwarciowej przeznaczonego do obwodów z wyłącznikami różnicowoprądowymi.
Every low voltage installation should be periodically tested for the evaluation of the effectiveness of protection against electric shock. In a TN type network a fault loop impedance or resistance test is performed. If a residual current device is installed in the tested circuit this test is problematic. The residual current device trips out during the test, because the measurement current is the residual current for the device. In the paper authors present the construction and principle of operation of a laboratory stand for verification of a new method of fault loop resistance measurement. This method enables measuring of fault loop resistance without nuisance tripping of residual current devices, in spite of the use of relatively high value of measuring current. The verification of the new method with the use of this laboratory stand is a base for construction of a prototype meter dedicated for circuits with residual current devices.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 51; 23-26
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wspomagana komputerowo lokalizacja strefy potencjału zerowego w eksploatacyjnych badaniach uziemień
Computer aided zero-potential space localization in earth resistance measurement
Autorzy:
Czapp, S.
Orlikowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/268730.pdf
Data publikacji:
2006
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Opis:
Dla dokładności pomiaru rezystancji uziemienia bardzo istotną rolę odgrywa właściwe umieszczenie sondy napięciowej w układzie pomiarowym. Sonda ta powinna się znajdować w tzw. strefie potencjału zerowego, co umożliwia zmierzenie napięcia uziomowego. W praktyce nieraz trudno jest zlokalizować strefę potencjału zerowego, szczególnie wtedy, kiedy do dyspozycji jest ograniczony obszar do rozmieszczenia uziomów pomocniczych na terenie miejskim. W artykule przedstawiono program komputerowy umożliwiający lokalizację strefy potencjału zerowe-w układach uziomami różnorodnymi uziomami prostymi. Aplikacja może być szczególnie przydatna przy pomiarach rezystancji uziemienia w gęstej zabudowie miejskiej lub na terenie zakładu przemysłowego.
Earthing resistance measurement accuracy especially depends on proper localization of the auxiliary voltage probe. This probe shall be placed in zero-potential space between tested electrode and the auxiliary current probe. In practice localization of the zero-potencial space is difficult particulary if the area surrounding the place of test is limited. In the paper special computer application dedicated for earthing resistance measurement is presented. This application is very useful if measurement is carried out in industry condition or in urban area.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2006, 22; 25-30
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości montażu diod laserowych na pasmo 808 nm poprzez pomiar rezystancji termicznej i charakterystyk spektralnych
Evaluation of the mounting quality of laser diodes emitting at 808nm by thermal resistance and spectral characteristics measurements
Autorzy:
Dąbrowska, E.
Teodorczyk, M.
Sobczak, G.
Malag, A.
Powiązania:
https://bibliotekanauki.pl/articles/192110.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Materiałów Elektronicznych
Tematy:
dioda laserowa
rezystancja termiczna
złącze p-n
pomiar termowizyjny
pomiar dynamiczny
charakterystyka spektralna
laser diode
thermal resistance
p-n junction
thermovision measurement
dynamics measurement
spectral characteristic
Opis:
W pracy przeanalizowano przesuwanie się charakterystyk spektralnych w diodach laserowych (DL) z różną rezystancją termiczną (R1), a także zmianę ich charakterystyk mocowo-prądowych na różnych etapach montażu. Mierzono wzrost temperatury złącza DL podczas przyłożonego impulsu prądowego poprzez dynamiczne (z rozdzielczością czasową) pomiary spektralne przy pomocy kamery ICCD. Porównano przesunięcia widm DL w czasie trwania impulsu o długości l ms w pomiarach dynamicznych i przesunięcia widm w czasie pomiarów przy stałej repetycji i zwiększającym się czasie trwania impulsu w zależności od wartości R1. Wyniki te posłużyły do opracowania metody oceny jakości montażu na etapie pomiarów impulsowych.
In this paper, the shift of spectral characteristics measured at a constant rate of bias pulse repetition and various pulse duration for laser diodes (LDs) with different thermal resistances has been presented. The temperature increase of the p-n junction of LDs during the current pulse has been investigated by dynamic (time-resolved) spectral measurements using an ICCD camera. For LDs with a different thermal resistance spectral shift during a 1 ms long pulse in dynamic measurements and in the measurements at a constant rate of pulse repetition with variable pulse duration has been demonstrated.
Źródło:
Materiały Elektroniczne; 2011, T. 39, nr 3, 3; 3-9
0209-0058
Pojawia się w:
Materiały Elektroniczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary temperatury powietrza w rejonie wybuchu głowicy RA-79 niekierowanego lotniczego pocisku rakietowego S-7
Air temperature measurements in the vicinity of explosion epicenter of 70-mm air-to-ground unguided missile warhead
Autorzy:
Długołęcki, A.
Faryński, A.
Ziółkowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/210028.pdf
Data publikacji:
2011
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
wybuch
działanie zapalające
termometr rezystancyjny
pomiar temperatury
explosion
incendiary action
resistance thermometer
temperature measurement
Opis:
Przedstawiono metodę i wyniki pomiarów temperatury (termometrem rezystancyjnym konstrukcji własnej) otaczającego powietrza w czasie eksplozji głowicy RA-79. Zastosowana metoda, przy podobnym zakresie zarejestrowanych zmian temperatury (ΔT ∼ 10 K), pozwoliła na uzyskanie znacznie większej rozdzielczości czasowej (ok. 300 μs), niż w przypadku termopar, zastosowanych gdzie indziej w podobnych eksperymentach (ok. 0,2 s).
Air temperature measurements in the vicinity of explosion epicenter of 70-mm air-to-ground unguided missile warhead Abstract. The measurement method, as well as the results of the ambient air temperature measurements (with an aid of the authors' construction resistance thermometer) during the RA-79 warhead explosion was presented. The method used enabled much greater time resolving power (300 μs) than in the case of thermocouples applied elsewhere in similar experiments (0.2 s).
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2011, 60, 2; 29-37
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Od kwantowego efektu Halla do rezystora wzorcowego - system przekazywania jednostki miary
From quantum Hall effect to standard resistor - transfer of resistance unit
Autorzy:
Domańska-Myśliwiec, D.
Mosiądz, M.
Snopek, L.
Powiązania:
https://bibliotekanauki.pl/articles/156783.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wzorzec rezystancji
reyzstor wzorcowy
jednostka miary
kwantowy efekt Halla
om
resistance standard
measurement unit
quantum Hall effect
ohm
Opis:
W referacie przedstawiono system przekazywania jednostki miary od układu odtwarzania jednostki rezystancji do rezystorów wzorcowych. Omówiono zasadę działania systemu odtwarzania jednostki rezystancji oraz wybrane problemy występujące podczas jej przekazywania do rezystorów wzorcowych. Przedstawiono również stanowiska wzorcujące służące temu celowi.
In the article structure of transferring resistance unit from quantum Hall effect to standard resistors is described. System of reproducing resistance unit fundamentals, chosen transfer problems, and calibration systems are also described.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 78-81
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza problemów pomiarów ciepła z wykorzystaniem hydrodynamicznego przepływomierza z wbudowanym rezystancyjnym czujnikiem temperatury
Analysis of problems of heat energy measurements with use of hydrodynamic flow-meters with embedded resistance temperature sensor
Autorzy:
Dorozhovets, M.
Kulyk, O.
Powiązania:
https://bibliotekanauki.pl/articles/152153.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary
ciepło
przepływomierz
czujnik temperatury
measurement
heat energy
flowmeter
temperature sensor
Opis:
Autorzy na podstawie analizy typowego układu pomiaru ilości ciepła wykazali, że ma on kilka wad, m.in. nieuwzględnienie możliwej zmiany przepływu masowego z powodu straty technologicznej cieczy lub jej nieuprawnionego odbioru oraz wpływu zmiany charakterystyk cieplnych cieczy ze zmianą temperatury. W udoskonalonym układzie pomiaru ilości ciepła wykorzystuje się dwa przepływomierze (na wejściu i wyjściu), co pozwala uwzględnić stratę masowego przypływu cieczy.
The authors consider typical systems for heat energy measurements (Fig. 1). It is assumed that the liquid mass flow input and output are the same in a typical system. If there are technological losses of heat liquid or its stealing in a heating system, the output amount of liquid is less than the input amount. Then the methodical measurement error of the heat energy (formula (2)) appears. Another component of the measurement error is due to the influence of temperature on the heat capacity of liquid which is different at the input and output of the heating system (formula (3)). To eliminate the above-mentioned methodological errors, the heat energy must be measured at the input and output of the heating system (formula (5)). For this purpose there was proposed an improved system for measuring the amount of heat (Fig. 3). In this system there are used two flow-meters (input and output), which allows taking into account possible losses in the heating liquid. Hence, the relationship between the temperature of the liquid heat capacity (also at the input and output) (Fig. 3) is taken into consideration, too. In order to increase the accuracy of determining the heat by measuring the amount of the liquid movement and its temperature at the same point (which eliminates the appropriate component of the systematic measurement error), the authors developed a hydrodynamic flow-meter with a built-in resistance temperature sensor (Fig. 4). The instrumental component of the error of measuring the heat quantity (which is caused by use of two flow meters instead of one) was examined (formulas (6, 7)).
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 11, 11; 1000-1002
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies