Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "repowering" wg kryterium: Wszystkie pola


Wyświetlanie 1-5 z 5
Tytuł:
The effect of parallel hot windbox repowering on 387 MW fossil fuel power plant
Autorzy:
Harutyunyan, A.
Badyda, K.
Wołowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/175190.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combined cycle power plant
fossil boiler
hot windbox repowering
CO2 emissions
Opis:
The paper presents the concept of repowering in existing power plant. Among technologies for existing steam power plants, the hot windbox repowering is the fastest way to respond to the energy demand, improve efficiency and reduce the pollutants emissions. Thermodynamic analysis of power plant model with fossil boiler before and after hot windbox repowering, has been investigated using commercial software. The purpose of this work is to understand and analyze the effect of hot windbox repowering on 387 MW fossil fuel power plant as well as the effect of additional heat exchangers, which have been installed parallel with regeneration system to use the heat of boiler exhaust gases. In this way, after repowering the summary power of power plant in base load is 615 MW, which has been reached adding gas turbine (176.9 MW). To analyze the model, calculations were performed in 3 stages: 1) calculation and comparison of the thermodynamic parameters as well as carbon dioxide emissions of power plant model before and after repowering, 2) analysis of the optimal value of feed water mass flow through heat exchangers installed after economizer, 3) calculation of thermodynamic parameters in values 100%, 90%, 80% and 75% of fossil boiler heat loads.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 131; 79-95
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Clean gas technologies - towards zero-emission repowering of Pomerania
Autorzy:
Ziółkowski, P.
Badur, J.
Powiązania:
https://bibliotekanauki.pl/articles/175502.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
clean gas technologies
clean coal technologies
zero emission
thermodynamic cycle
steam-gas turbine
oxy combustion
carbon capture storage
Opis:
In the paper a brief review of processes for energy conversion developed recently within the framework of clean gas te chnologies is presented, in cluding projects for future repowering of Pomerania. The main aim of this work is to show the diferent thermodynamcs cycles which improve efficiency and/or decrease emissions such as: Cheng cycle, Szewalski cycle, LOTHECO cycle, hybrid pSOFC/GT cycle, inverse Brayton cycle, low-emission cycle and zero-emission cycle. For that purpose,cycles and results of analysis are frst studied and, secondly, new concept is presented. The role of coupled analysis 0D and 3D in cycle's devices is also discussed.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2012, 124; 51-80
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconditioning in synchronous operation with one parallel induction generator
Autorzy:
Magalhães, A. S.
Moraes, P. H. F.
Silva, A. H. F.
Gomes, P. H. G.
Alves, A. J.
Calixto, W. P.
Powiązania:
https://bibliotekanauki.pl/articles/136216.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
repowering
induction generator
synchronous generator
harmonics
Opis:
The purpose of this paper is to compare mathematical modeling and practical bench in order to validate the electrical interactions between an induction generator and a synchronous generator. Two generators was connected to a common bus in steady state, subject to non-linear load. The results comparing modeling and bench tests show that the induction generator besides the active power increasing, has a better way for harmonic currents flowing in common bus. It was concluded that the induction generator repowering and attenuates current harmonic components present at the connection point, improving the network voltage profile.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 4; 66-72
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the Optimal Structure of Repowering a Metallurgical CHP Plant Fired with Technological Fuel Gases
Dobór optymalnej struktury elektrociepłowni gazowo-parowej opalanej hutniczymi gazami palnymi
Autorzy:
Ziębik, A.
Warzyc, M.
Gładysz, P.
Powiązania:
https://bibliotekanauki.pl/articles/352232.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combined gas-and-steam cycle
metallurgical CHP plant
structure optimization
probabilistic approach
elektrociepłownia hutnicza
układ gazowo-parowy
optymalizacja struktury
podejście probabilistyczne
Opis:
CHP plants in ironworks are traditionally fired with low-calorific technological fuel gases and hard coal. Among metallurgical fuel gases blast-furnace gas (BFG) dominates. Minor shares of gaseous fuels are converter gas (LDG) and surpluses of coke-oven gas (COG). Metallurgical CHP plant repowering consists in adding a gas turbine to the existing traditional steam CHP plant. It has been assumed that the existing steam turbine and parts of double-fuel steam boilers can be used in modernized CHP plants. Such a system can be applied parallelly with the existing steam cycle, increasing the efficiency of utilizing the metallurgical fuel gases. The paper presents a method and the final results of analyzing the repowering of an existing metallurgical CHP plant fired with low-calorific technological fuel gases mixed with hard coal. The introduction of a gas turbine cycle results in a better effectiveness of the utilization of metallurgical fuel gases. Due to the probabilistic character of the input data (e.g. the duration curve of availability of the chemical energy of blast-furnace gas for CHP plant, the duration curve of ambient temperature) the Monte Carlo method has been applied in order to choose the optimal structure of the gas-and-steam combined cycle CHP unit, using the Gate Cycle software. In order to simplify the optimizing calculation, the described analysis has also been performed basing on the average value of availability of the chemical energy of blast-furnace gas. The fundamental values of optimization differ only slightly from the results of the probabilistic model. The results obtained by means of probabilistic and average input data have been compared using new information and a model applying average input data. The new software Thermoflex has been used. The comparison confirmed that in the choice of the power rating of the gas turbine based on both computer programs the results are similar.
Tradycyjnie elektrociepłownie hutnicze są opalane niskokalorycznymi palnymi gazami technologicznymi w mieszaninie z pyłem węgla kamiennego. W mieszaninie gazów dominujący jest udział gazu wielkopiecowego. Znacznie mniejsze są udziały gazu koksowniczego i konwertorowego. Modernizacja elektrociepłowni hutniczej (tzw. repowering) polega na dobudowaniu do istniejącej struktury członu gazowego. W analizie założono możliwość wykorzystania istniejących turbin parowych oraz części dwupaliwowych kotłów parowych. Układ gazowo-parowy zostanie połączony równolegle z istniejącym obiegiem parowym, zwiększając tym samym efektywność energetyczną wykorzystania niskokalorycznych gazów hutniczych. W artykule zaprezentowano metodologię oraz wyniki końcowe przeprowadzonej analizy modernizacji istniejącej elektro- ciepłowni hutniczej opalanej niskokalorycznymi gazami hutniczymi w mieszance z pyłem węgla kamiennego. Bazowano przy tym na zbiorze danych wejściowych z lat 1996-2000. Z uwagi na probabilistyczny charakter danych wejściowych (min. wykres uporządkowany dostępności energii chemicznej gazu wielkopiecowego oraz wykres uporządkowany temperatury zewnętrznej) wykorzystano metodę Monte Carlo w celu doboru optymalnej struktury kombinowanego gazowo-parowego układu elektrocie- płowni wykorzystując do tego oprogramowanie Gate Cycle. Obliczenia optymalizacyjne zostały również przeprowadzone w oparciu o uśrednioną wartość strumienia energii chemicznej gazu wielkopiecowego dostępnego dla elektrociepłowni. Wyniki obliczeń podstawowych parametrów z tej analizy różnią się w nieznacznym stopniu od wyników uzyskanych za pomocą modelu probabilistycznego. Wyniki uzyskane zarówno z metody probabilistycznej, jak i bazującej na wartościach średnich danych wejściowych zostały porównane z rezultatami obliczeń w oparciu o nowy zestaw danych (lata 2005-2008), jak również nowy model utworzony w programie Thermotlex oraz Engineering Equation Solver. Obliczenia zostały przeprowadzone w oparciu o uśredniony strumień energii chemicznej gazu wielkopiecowego dostępnego dla elektrociepłowni. Zastosowane do doboru struktury modernizowanej elektrociepłowni hutniczej programy komputerowe Gate Cycle i Thermoflex dały zbliżone rezultaty.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 1; 105-116
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of structure of heat recovery steam generator and of gas turbogenerator power repowering a 370 MW unit on the power plant operating in cogeneration cycle
Wpływ struktury kotła odzyskowego i mocy turbozespołu gazowego nadbudowujących blok 370 MW na jego pracę - praca skojarzona bloku
Autorzy:
Bartnik, R.
Buryn, Z.
Duczkowska-Kądziel, A.
Powiązania:
https://bibliotekanauki.pl/articles/173157.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kocioł odzyskowy
turbozespół gazowy
turbina parowa
heat recovery steam generator
gas turbogenerator
steam turbine
Opis:
W artykule zaprezentowano rezultaty termodynamicznych obliczeń doboru struktury kotła odzyskowego i mocy turbozespołu gazowego do bloku o mocy 370 MW zmodernizowanego do dwupaliwowego układu gazowo-parowego. Obliczenia przeprowadzono dla pracy skojarzonej bloku.
The paper presents results of technical calculations involving the selection of a structure of heat recovery steam generator and of gas turbogenerator power applied for adaptation of a coal-fired power unit with the rated capacity of 370 MW to dual-fuel steam-gas system. Calculations were conducted for a unit operating under cogeneration cycle.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 197-210
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies