Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "refrigerators" wg kryterium: Wszystkie pola


Wyświetlanie 1-14 z 14
Tytuł:
Adsorptive solar refrigerators based on composite adsorbents 'silica gel – sodium sulphate'
Autorzy:
Belyanovskaya, Elena A.
Pustovoy, Grigoriy N.
Sukhyy, Kostyntyn M.
Sergiyenko, Yana O.
Yeromin, Oleksandr O.
Prokopenko, Elena .
Gubinsky, Mikhailo V.
Kizek, Ján
Lukáč, Ladislav
Powiązania:
https://bibliotekanauki.pl/articles/396041.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
adsorptive refrigerator
composite adsorbent
coefficient of performance
adsorptive capacity
regeneration temperature
chłodziarka adsorpcyjna
adsorbent
współczynnik wydajności
zdolność adsorpcyjna
temperatura
Opis:
The operation processes of adsorptive solar refrigerators based on composite adsorbents ‘silica gel - sodium sulphate’ were studied. The correlation between the adsorbent composition and the coefficient of the energy performance of the device was stated. As a consequence of the decreasing of adsorbent mass, the coefficient of performance is increased when sodium sulphate content in the composite increased. Effect of the regeneration process parameters on the composite on the coefficient of performance of the adsorptive refrigenerator was stated. The growth of the coefficient of performance is shown to result from decreasing the difference between adsorbent temperature and regeneration temperature from 85 to 55°C. The maximum values of the coefficient of performance of studied solar adsorptive refrigenerator about of 1.14 are stated for composites containing about 20 wt. % silica gel and 80 wt. % sodium sulphate.
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 3; 200-208
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kierunki rozwoju i badań termoakustycznych urządzeń chłodniczych z falą stojącą
The directions of development and research on the thermoacoustic refrigerators with the standing wave
Autorzy:
Kajurek, Jakub
Rusowicz, Artur
Powiązania:
https://bibliotekanauki.pl/articles/111123.pdf
Data publikacji:
2019
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
perspektywiczna technologia chłodnicza
termoakustyka
chłodzenie termoakustyczne
termoakustyczne urządzenie chłodnicze
perspective cooling technology
thermoacoustics
thermoacoustic refrigeration
thermoacoustic refrigerator
Opis:
Chłodzenie termoakustyczne to perspektywiczna technologia, która wykorzystuje energię fali akustycznej do transportu ciepła z ośrodka o niskiej do ośrodka o wysokiej temperaturze. Do głównych zalet tej technologii zalicza się dużą niezawodność, prostą konstrukcję urządzeń, a przede wszystkim brak szkodliwych dla środowiska czynników chłodniczych. Z drugiej strony wadą tej technologii jest relatywnie niska sprawność w porównaniu do współczesnych rozwiązań konwencjonalnych. Głównie z tej przyczyny urządzenia termoakustyczne wciąż pozostają w fazie szerokich badań mających na celu poprawę ich wydajności. W artykule tym przedstawiono kierunki obecnie prowadzanych prac. Uwagę zwrócono zwłaszcza na badania eksperymentalne z zakresu wyboru optymalnych parametrów konstrukcyjnych i eksploatacyjnych termoakustycznych urządzeń chłodniczych z falą stojącą. Omówiono również budowę oraz podstawową zasadę działania takich urządzeń.
Thermoacoustic refrigeration is a perspective technology capable of transporting heat from a low temperature source to a high-temperature source by utilizing the acoustic power input. It shows the advantages of high reliability, simple construction and operating without hazardous refrigerants. On the other hand, this technology has disadvantage of relative low efficiency in comparison to conventional solutions. Thus, many efforts have been taken in order to improve the performance of the thermoacoustic coolers. The article presents the review of current research. The main attention is focused on the experimental investigations of the optimal selection of the design and the operational parameters of the thermoacoustic refrigerators with the standing wave. The construction and principles of operations of such devices are also described in this paper.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2019, 4
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of adsorption chillers for waste heat recovery
Wykorzystanie chłodziarek adsorpcyjnych do zagospodarowania ciepła odpadowego
Autorzy:
Kuchmacz, Jan
Bieniek, Artur
Mika, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/283345.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
waste heat
heat recovery
energy efficiency
adsorption refrigerators
ciepło odpadowe
odzysk ciepła
efektywność energetyczna
chłodziarka adsorpcyjna
Opis:
The purpose of this article was to discuss the use of adsorption chillers for waste heat recovery. The introduction discusses the need to undertake broader measures for the effective management of waste heat in the industry and discusses the benefits and technical problems related to heat recovery in industrial plants. In addition, heat sources for adsorption chillers and their application examples were described. The principle of operation of adsorption chillers is explained in the next chapter. Heat sources for adsorption chillers are indicated and their application examples are described. The above considerations have allowed the benefits and technical obstacles related to the use of adsorption chillers to be highlighted. The currently used adsorbents and adsorbates are discussed later in the article. The main part of the paper discusses the use of adsorption chillers for waste heat management in the glassworks. The calculations assumed the natural gas demand of 20.1 million m3 per year and the electricity demand of 20,000 MWh/year. As a result of conducted calculations, a 231 kW adsorption chiller, ensuring the annual cold production of 2,021 MWh, was selected. The economic analysis of the proposed solution has shown that the investment in the adsorption chiller supplied with waste heat from the heat recovery system will bring significant economic benefits after 10 years from its implementation, even with total investment costs of PLN 1,900,000. However, it was noted that in order to obtain satisfactory economic results the production must meet the demand while the cost of building a heat recovery system shall not exceed PLN 1 million.
Celem artykułu było rozważenie problemu zagospodarowywania ciepła odpadowego przy wykorzystaniu chłodziarek adsorpcyjnych. Na początku wskazano genezę potrzeby podjęcia szerszych działań na rzecz efektywnego zagospodarowywania ciepła odpadowego w przemyśle oraz omówiono korzyści i problemy techniczne związane z odzyskiem ciepła w zakładach przemysłowych. W następnym rozdziale objaśniono zasadę działania chłodziarek adsorpcyjnych. Z kolei wskazano źródła ciepła dla chłodziarek adsorpcyjnych oraz opisano ich przykładowe zastosowania. Powyższe rozważania pozwoliły na uwypuklenie korzyści i barier technicznych związanych z wykorzystywaniem adsorpcyjnych urządzeń chłodniczych. W następnej części pracy scharakteryzowano stosowane obecnie adsorbenty i adsorbaty. W zasadniczej części pracy przeprowadzono analizę wykorzystania chłodziarek adsorpcyjnych do zagospodarowania ciepła odpadowego w hucie szkła. W obliczeniach rozważono przykładową hutę szkła, której zapotrzebowanie na gaz ziemny wynosi 20,1 mln m3/rok, a zapotrzebowanie na energię elektryczną wynosi 20 000 MWh/rok. W efekcie przeprowadzonych kalkulacji dobrano chłodziarkę adsorpcyjną o mocy 231 kW, która zapewni roczną produkcję chłodu wynoszącą 2021 MWh. Analiza ekonomiczna zaproponowanego rozwiązania wykazała, że inwestycja w chłodziarkę adsorpcyjną zasilaną ciepłem odpadowym z instalacji odzysku ciepła przyniesie znaczące korzyści ekonomiczne po 10 latach od jej zrealizowania nawet przy sumarycznych nakładach inwestycyjnych wynoszących 1 900 000 zł. Zaznaczono jednak, że uzyskanie tak zadawalających wyników ekonomicznych będzie możliwe tylko wtedy, gdy w hucie szkła będzie zapewniony ciągły odbiór chłodu, a koszt budowy instalacji odzysku ciepła nie przekroczy 1 mln zł.
Źródło:
Polityka Energetyczna; 2019, 22, 2; 89-106
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Functional dependencies of thermodynamic and thermokinetic parameters of refrigerants used in mine air refrigerators. Part 2 – Rrefrigerant R404A
Zależności funkcyjne parametrów termodynamicznych i termokinetycznych czynników chłodniczych stosowanych w górniczych chłodziarkach powietrza. Część 2 – Czynnik chłodniczy R404A
Autorzy:
Nowak, B.
Życzkowski, P.
Łuczak, R.
Powiązania:
https://bibliotekanauki.pl/articles/219558.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermokinetic parameters
czynniki chłodnicze
czynnik chłodniczy R404A
parametry termodynamiczne
parametry termo-kinetyczne
refrigerants
R404A refrigerant
thermodynamic parameters
Opis:
This paper deals with thermodynamic and thermokinetic properties of R404A refrigerant, which is one of the more commonly used in mine air compression refrigerators. Knowledge of these parameters is essential to analyze performance of such refrigeration equipment, to design it, or to estimate efficiency of air refrigerators using various refrigerants. These properties can be defined using 27 simple computational formulas, contained in 4 tables (Tables 2, 6, 10 and 12). The relationships determining thermodynamic and thermokinetic parameters of R404A occur in saturated liquid region, dry saturated vapor region, superheated vapor region and supercooled liquid region. The developed relationships were subjected to statistical verification. For this purpose, correlation coefficients, coefficients of determination, as well as absolute and relative deviations were determined by comparing results of the calculations with the corresponding results obtained by REFPROP 7 (Lemmon et al., 2002). Results of verification are contained in Tables 14 and 15.
Artykuł dotyczy właściwości termodynamicznych i termokinetycznych czynnika chłodniczego R404A, który jest jednym z częściej stosowanych w górniczych sprężarkowych chłodziarkach. Znajomość tych parametrów jest wymagana do analizy pracy takich chłodziarek, do ich projektowania, czy też do oceny efektywności pracy chłodziarek wykorzystujących różne czynniki chłodnicze. Wymienione właściwości określić można korzystając z utworzonych 27 prostych formuł obliczeniowych. Podano je w 4 tabelach (tabela 2, 6, 10 i 12). Przedstawione zależności określające parametry termodynamiczne i termokinetyczne czynnika chłodniczego R404A obowiązują w stanie cieczy nasyconej, w stanie pary nasyconej suchej, w stanie pary przegrzanej oraz w stanie cieczy przechłodzonej. Opracowane zależności poddano weryfikacji statystycznej. W tym celu, porównując wyniki obliczeń z odpowiednimi wynikami uzyskanymi programem REFPROP 7 (Lemmon i inni, 2002) określono współczynniki korelacji, determinacji oraz odchyłki bezwzględne i względne. Rezultaty weryfikacji zamieszczono w tabelach 14 i 15.
Źródło:
Archives of Mining Sciences; 2018, 63, 1; 27-41
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Functional dependence of thermodynamic and thermokinetic parameters of refrigerants used in mine air refrigerators. Part 1 – Refrigerant R407C
Zależności funkcyjne parametrów termodynamicznych i termokinetycznych czynników chłodniczych stosowanych w górniczych chłodziarkach powietrza. Część 1 – Czynnik chłodniczy R407C
Autorzy:
Nowak, B.
Życzkowski, P.
Łuczak, R.
Powiązania:
https://bibliotekanauki.pl/articles/219737.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
czynniki chłodnicze
R407C
parametry termodynamiczne i termokinetyczne
refrigerants
thermodynamic and thermokinetic parameters
Opis:
The authors of this article dealt with the issue of modeling the thermodynamic and thermokinetic properties (parameters) of refrigerants. The knowledge of these parameters is essential to design refrigeration equipment, to perform their energy efficiency analysis, or to compare the efficiency of air refrigerators using different refrigerants. One of the refrigerants used in mine air compression refrigerators is R407C. For this refrigerant, 23 dependencies were developed, determining its thermodynamic and thermokinetic parameters in the states of saturated liquid, dry saturated vapour, superheated vapor, subcooled liquid, and in the two-phase region. The created formulas have been presented in Tables 2, 5, 8, 10 and 12, respectively. It should be noted that the scope of application of these formulas is wider than the range of changes of that refrigerant during the normal operation of mine refrigeration equipment. The article ends with the statistical verification of the developed dependencies. For this purpose, for each model correlation coefficients and coefficients of determination were calculated, as well as absolute and relative deviations between the given values from the program REFPROP 7 (Lemmon et al., 2002) and the calculated ones. The results of these calculations have been contained in Tables 14 and 15.
Autorzy niniejszego artykułu zajęli się zagadnieniem modelowania właściwości (parametrów) termodynamicznych i termokinetycznych czynników chłodniczych. Znajomość tych parametrów jest niezbędna do projektowania urządzeń chłodniczych, ich analizy energetycznej, a także do porównaniu efektywności pracy chłodziarek powietrza wykorzystujących różne czynniki chłodnicze. Jednym ze stosowanych w górniczych sprężarkowych chłodziarkach powietrza czynnikiem chłodniczym jest R407C. Dla wymienionego czynnika chłodniczego opracowano 23 zależności określające jego parametry termodynamiczne i termokinetyczne w stanie cieczy nasyconej, w stanie pary nasyconej suchej, w stanie pary przegrzanej, w stanie cieczy przechłodzonej oraz w stanie pary mokrej. Utworzone wzory podano odpowiednio w tabelach: 2, 5, 8, 10 i 12. Należy zaznaczyć, że zakresy obowiązywania tych wzorów są szersze od zakresów zmian tego czynnika podczas normalnej pracy górniczych urządzeń chłodniczych. Artykuł kończy weryfikacja statystyczna utworzonych zależności. W tym celu dla każdego wzoru obliczono współczynniki korelacji, determinacji oraz odchyłki bezwzględne i względne między wartościami danymi z programu REFPROP 7 (Lemmon i in., 2002) a obliczonymi. Rezultaty tych obliczeń zamieszczono w tabelach 14 i 15.
Źródło:
Archives of Mining Sciences; 2017, 62, 1; 55-72
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekologiczne chłodziarki magnetyczne
Ecological magnetic refrigerators
Autorzy:
Sulima, R.
Powiązania:
https://bibliotekanauki.pl/articles/159969.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
chłodzenie magnetyczne
materiały magnetokaloryczne
magnesy trwałe
analiza polowa 2D
analiza polowa 3D
magnetic refrigeration
magnetocaloric materials
adiabatic demagnetization
permanent magnets
2D field analysis
3D field analysis
Opis:
Artykuł opisuje cykl przemiany energii w materiałach magnetokalorycznych, prototypy wybranych konstrukcji układów chłodzących, ich wady i zalety. Przedstawiono również tło polityczne i warunki środowiskowe wymagane przez UE w stosunku do urządzeń chłodniczych i klimatyzacyjnych.
The magnetocaloric effect (MCE) is a thermodynamic process in which the temperature changes of a paramagnetic material are the effect of an external magnetic field changing in cycles. The refrigeration occurs in two stages: the first one is the isothermal magnetizing of the material, during which the intensity of the magnetic field rises from H0 to H3 (Fig. 1 process 1-2); during the magnetizing the dipoles of the paramagnetic material become arranged parallely to the intensity of the external magnetic field and the entropy of the material decreases from S1 to S2. As a result of magnetizing, heat is transferred to the surroundings in a quantity proportional to the work executed by the magnetic field. The second stage is the adiabatic demagnetization of the paramagnetic material to the value of the field intensity of H0, during which there occures a decrease in temperature of the material from Tp to T12 (Fig. 2 process 2-3).
Źródło:
Prace Instytutu Elektrotechniki; 2013, 261; 117-128
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of temperature glide of R407C refrigerant on the power of evaporator in air refrigerators
Wpływ poślizgu temperatury czynnika chłodniczego R407C na moc parownika chłodziarki powietrza
Autorzy:
Nowak, B.
Życzkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/220127.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
czynnik chłodniczy R407C
poślizg temperatury
chłodziarka powietrza
parownik
R407C refrigerant
temperature glide
air refrigerator
evaporator
Opis:
The article discusses the effect of the phenomenon of temperature glide of zeotropic refrigerants on thermal power of an evaporator in an air compression refrigerator. Zeotropic mixtures are subject to phase transitions, the process of which significantly differs from that of homogeneous refrigerants. In contrast to homogeneous refrigerants, where boiling and condensing processes take place at a constant temperature, for the zeotropic mixtures it is essential to know the vapor quality to unambiguously determine the temperature at which the evaporation process is initiated. The R407C refrigerant serves as an example to describe the method of determining the initial temperature of the evaporation process taking into account the effect of temperature glide. The developed formula (7) has been based on a proven linear course of isobars in the two-phase region (Fig. 5) and thus determining a polynomial describing their angle of inclination (8). In addition, temperature calculation formulas (9) and specific enthalpy (10) of dry saturated vapor of the R407C refrigerant have been presented as well. This approach allows to determine the temperature of the R407C refrigerant at the inlet to the evaporator without the required knowledge of its vapor quality. The previously used simplified methods for determining the temperature of a refrigerant at the inlet to the evaporator result in considerable deviations in calculated power of the evaporator compared with its actual value. The presented calculation example involving mine air compression refrigerator of TS-450P type shows that relative deviations of the evaporator thermal power may even exceed 20%. This example compares two simplified methods for determining zeotropic evaporating temperature of a refrigerant used in comparative calculations of refrigerants with the method presented in this article.
W artykule przedstawiono wpływ zjawiska poślizgu temperatury zeotropowych czynników chłodniczych na moc cieplną parownika sprężarkowej chłodziarki powietrza. Mieszaniny zeotropowe podlegają przemianom fazowym, których przebieg znacznie różni się od czynników jednorodnych. W odróżnieniu od jednorodnych czynników chłodniczych, których procesy wrzenia i skraplania odbywają się przy stałej temperaturze, dla mieszanin zeotropowych do jednoznacznego określenia temperatury początku procesu parowania niezbędna jest znajomość stopnia suchości pary. Na przykładzie czynnika chłodniczego R407Copisano metodę wyznaczania temperatury początkowej procesu parowania uwzględniającą zjawisko poślizgu temperatury. Opracowana zależność (7) powstała w oparciu o udowodniony liniowy przebieg izobar w obszarze pary mokrej (rys. 5) i określeniu na tej podstawie wielomianu opisującego ich kąt nachylenia (8). Dodatkowo przedstawiono wzory obliczeniowe temperatury (9) oraz entalpii właściwej (10) pary nasyconej suchej czynnika chłodniczego R407C. Takie podejście do problemu pozwala na wyznaczenie temperatury czynnika chłodniczego R407C na wlocie do parownika bez wymaganej znajomości stopnia suchości pary czynnika. Dotychczas stosowane uproszczone metody wyznaczania temperatury czynnika chłodniczego na wlocie do parownika powodują znaczne odstępstwa obliczonej na ich podstawie mocy parownika od jego wartości rzeczywistej. Przedstawiony przykład obliczeniowy dotyczący górniczej sprężarkowej chłodziarki powietrza pośredniego działania typu TS-450P pokazuje, że odchyłki względne mocy cieplnej parownika mogą przekraczać nawet ponad 20%. W przykładzie obliczeniowym porównano dwie uproszczone metody określenia temperatury parowania zeotropowego czynnika chłodniczego stosowane w obliczeniach porównawczych czynników chłodniczych z metodą zaprezentowaną w niniejszym artykule.
Źródło:
Archives of Mining Sciences; 2013, 58, 4; 1333-1346
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat power determination of Dv-290 refrigerator’s evaporator on the basis of thermodynamic parameters of inlet air
Określenie mocy cieplnej parownika chłodziarki Dv-290 na podstawie parametrów termodynamicznych powietrza wlotowego
Autorzy:
Nowak, B.
Kuczera, Z.
Powiązania:
https://bibliotekanauki.pl/articles/218808.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
klimatyzacja kopalń
chłodzenie powietrza
chłodziarka sprężarkowa
moc cieplna
air conditioning of mines
air cooling
compression refrigerator
thermal power
Opis:
The present paper introduces a method for calculating the thermal power of DV-290 mining air cooler’s evaporator. The power usually differs from the nominal power given by the manufacturer. The thermodynamic parameters of cooled air are not obtained as a result of in situ measurements, but in indirect manner that is by determining the evaporation and condensation’s pressure values of R407C refrigerant. The pressure dependencies formulated as a function of air enthalpy at the evaporator’s inlet were obtained using calculations of a computer program which solves the system of equations describing heat and mass transfer in the refrigerator’s compressor on the basis of previous measurements of air performed before and after its cooling. The obtained dependencies are demonstrated in a graphical (fig. 2 and fig. 3) and analytical (the regression equations (19) and (20)) manner, the values of correlation coefficients are also presented. For the known evaporation and condensation pressure values of the refrigerant, and thus for its basic physical parameters the complete thermal power of the evaporator was determined, that is its: air cooling overt power, dehumidification occult power, temperature, relative humidity and specific humidity of air after its cooling. In addition, using the mentioned method, the capacity of DV-290 refrigerator’s evaporator is provided for the given thermodynamic parameters of air before cooling, along with air thermodynamic parameters after cooling.
W pracy zaproponowano metodę obliczania mocy cieplnej parownika górniczej chłodziarki powietrza DV-290. Moc ta zazwyczaj jest różna od mocy znamionowej podanej przez jej producenta. Wymaganą znajomość parametrów termodynamicznych schłodzonego powietrza otrzymuje się, nie jak dotychczas w wyniku ich pomiarów in situ, lecz drogą pośrednią wyznaczając najpierw wartości ciśnień parowania i skraplania czynnika chłodniczego R407C. Odpowiednie zależności tych ciśnień w funkcji jednostkowej entalpii powietrza na wlocie parownika otrzymano, na podstawie wcześniejszych pomiarów parametrów powietrza przed i po jego schłodzeniu, z obliczeń utworzonym programem komputerowym rozwiązującym układ równań opisujący wymianę ciepła i masy w chłodziarce sprężarkowej. Uzyskane zależności przedstawiono w sposób graficzny (rys. 2 i rys. 3) oraz analityczny - równania regresji (19) i (20), podając też wartości współczynników korelacji. Dla znanych wartości ciśnień parowania i skraplania czynnika chłodniczego, a więc także i jego podstawowych parametrów fizycznych, korzystając z wymienionego programu komputerowego, wyznaczono, w funkcji jednostkowej entalpii powietrza na wlocie parownika, całkowitą jego moc cieplną z podziałem na moc jawną ochładzania powietrza, utajoną moc osuszania powietrza, temperaturę, wilgotność względną i wilgotność właściwą powietrza po jego ochłodzeniu. Podano też, dla przykładowych zadanych parametrów termodynamicznych powietrza przed jego schłodzeniem obliczone wspomnianą metodą, moce parownika chłodziarki DV-290 oraz parametry termodynamiczne powietrza po schłodzeniu.
Źródło:
Archives of Mining Sciences; 2012, 57, 4; 911-920
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena mikroflory w powietrzu chłodziarek w gospodarstwach domowych
Estimate of the air microflora of the refrigerators from houshold
Autorzy:
Kawecka, W.
Wrońska, A.
Tarkowska, B.
Powiązania:
https://bibliotekanauki.pl/articles/228356.pdf
Data publikacji:
2012
Wydawca:
Wyższa Szkoła Menedżerska w Warszawie
Tematy:
zanieczyszczenia mikrobiologiczne żywności
chłodzenie
Listeria monocytogenes
Bacillus sp1
grzyby strzępkowe
microbiological contamination
filamentous fungi
Opis:
Przechowywana w warunkach chłodniczych żywność stanowi dobrą pożywkę dla rozwoju mikroorganizmów. Celem przeprowadzonych badań była ocena stopnia zanieczyszczeń mikrobiologicznych powietrza w urządzeniach chłodniczych w gospodarstwach domowych. W prowadzonych badaniach wykazano obecność zarodników bakterii saprofitycznych oraz chorobotwórczych szczepów Listeria monocytogenes oraz grzybów potencjalnie toksynotwórczych z rodzajów Aspergillus i Penicillium.
Food presents good source in cooling conditions for development of microorganism stored. The aim of investigation there was the opinion of microbiological contamination of the air of refrigerators from household. Presence of presence exert in composition microflora pathogenic spores Listeria monocytogenes, Bacillus sp. and spores potential toxinogenic filamentous fungi of genres Aspergillus and Penicillium.
Źródło:
Postępy Techniki Przetwórstwa Spożywczego; 2012, 1; 43-46
0867-793X
2719-3691
Pojawia się w:
Postępy Techniki Przetwórstwa Spożywczego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy górniczej chłodziarki powietrza pośredniego działania z wewnętrznym wymiennikiem ciepła
An analysis of work of mine air compression refrigerator of indirect action with internal heat exchanger
Autorzy:
Życzkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/349130.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
klimatyzacja
wewnętrzny wymiennik ciepła
chłodziarki
właściwa wydajność chłodnicza
air-conditioning
internal heat exchanger
refrigerators
refrigeration capacity
Opis:
W artykule przedstawiono analizę pracy górniczej chłodziarki powietrza pośredniego działania typu TS-450P z wewnętrznym wymiennikiem ciepła. Wykazano wpływ zastosowania wewnętrznego wymiennika ciepła na parametry pracy chłodziarki takie jak jednostkowa wydajność chłodnicza, właściwa praca sprężania czy współczynnik wydajności chłodniczej.
An analysis of work of mine air compression refrigerator TS-450P type with internal heat exchanger was described in this article. Influence of internal heat exchanger on main parameters of work of air compression refrigerator: refrigeration capacity, specific compression work and refrigerating capacity coefficient was demonstrated.
Źródło:
Górnictwo i Geoinżynieria; 2011, 35, 1; 107-123
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Środowiskowa ocena oddziaływania chłodziarko-zamrażalek w procedurze ekoprojektowania sprzętu AGD
Environmental evaluation of refrigerators impacts in household equipment ecodesign
Autorzy:
Lewicki, R.
Kurczewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/2071628.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ekoprojektowanie
analiza cyklu życia
LCA
LCM
DFE
ecodesign
life cycle assessment (LCA)
DfE
Opis:
W artykule przedstawiono wyniki oddziaływania chłodziarko-zamrażarek na środowisko w ujęciu cyklu ich istnienia. Ocena metodą LCA została przeprowadzona za pomocą programu Sima Pro 7 przy wykorzystaniu metodyki Eco-indicator 99. Analizę przeprowadzono dla wszystkich etapów cyklu życia. Uzyskane wyniki umożliwiły identyfikację dominujących, pod względem poziomu wywieranego oddziaływania, etapów cyklu życia chłodziarko-zamrażarki.
The results of LCA analysis are presented in the paper. A refrigerator was taken as the object in the whole life cycle. Sima Pro 7 and Eco-indicator 99 software were used for calculations. Every stage of life cycle was considered. Results enabled one to indicate the stages of life cycle (material and processes) that impact decidedly on the environment.
Źródło:
Inżynieria i Aparatura Chemiczna; 2011, 2; 40-41
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu wewnętrznego wymiennika ciepła na moc cieplną górniczych chłodziarek powietrza
The analysis of impact of internal heat exchanger on thermal power of mining air refrigerators
Autorzy:
Życzkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/349035.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wewnętrzny wymiennik ciepła
chłodziarki
klimatyzacja
internal heat exchanger
refrigerators
air-conditioning
Opis:
Zastosowanie wewnętrznego wymiennika ciepła (internal heat exchanger - IHX) w układzie chłodniczym pozwala na zwiększenie wydajności chłodniczej urządzeń chłodniczych. W artykule przedstawiono analizę zmian mocy cieplnej i współczynników wydajności chłodniczej górniczych chłodziarek powietrza typu TS-300 oraz TS-450P przez instalację wewnętrznego wymiennika ciepła.
An use of internal heat exchanger (IHX) in refrigerating system allows increasing the refrigerating capacity of refrigerators. The analysis of the changes of thermal power and refrigerating capacity of TS-300 and TS-450P mining refrigerators types with internal heat exchanger were described in this article.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 3/1; 187-200
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eksperymentalne badania pracy górniczych sprężarkowych chłodziarek powietrza współpracujących z wyparnymi chłodnicami wody
Experimental researches on the performance of mining compression type of air refrigerators cooperating with evaporative water coolers
Autorzy:
Nowak, B.
Filek, K.
Łuska, P.
Powiązania:
https://bibliotekanauki.pl/articles/349051.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
klimatyzacja kopalń
górnicza chłodziarka powietrza
chłodnica wyparna
mine air conditioning
mine refrigerator
evaporative water cooler
Opis:
W artykule podano wyniki pomiarów parametrów pracy stosowanych w kopalniach podziemnych chłodziarek powietrza typu DV-290 i TS-300B i użytych do chłodzenia wody chłodnic wyparnych RK-450 i CWW-420. Mierzono strumienie masy lub objętości oraz temperaturę na wlotach i wylotach wymienników przeponowych - parowników, skraplaczy i wyparnych chłodnic wody wszystkich występujących w układzie mediów - powietrza, czynnika chłodniczego i wody, a także ciśnienie powietrza i czynnika chłodniczego. Do określenia wilgotności powietrza mierzono jego temperaturę zarówno termometrem suchym, jak i wilgotnym. Na podstawie otrzymanych rezultatów eksperymentów z podanych wzorów wyliczono moc cieplną wszystkich wymienników. Wszystkie dane zestawiono w tabelach i na wykresach.
Measurement results of the work parameters applied to two types of air refrigerators: DV-290 and TS-300B located in underground mines and used by two evaporative water coolers: RK-450 and CWW-420 are presented in this paper. Parameters of the mass or the capacity flows were measured as well as the inlets and the outlets' temperature of the diaphragmatic exchangers - evaporators, condensers and evaporated water coolers for all of the mediums occured in the system - air, water, atmospheric pressure and the refrigerating medium. The air moisture was measured using the dry and wet bulb thermometer. Thermal power of all of the exchangers was determined on the basis of the results of the experiments. All the data were presented in the form of charts and tables.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 3/1; 101-115
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Samoocena dostawców surowca mlecznego w zakresie wyposażenia ich gospodarstw w urządzenia techniczne do pozyskiwania mleka
Self-assessment of tradesmen in range of equipment their farms in technical devices to logging of milk
Autorzy:
Czarnociński, F.
Lipiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/288373.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
dojarka mechaniczna
schładzarki do mleka
wyposażenie techniczne
obora
milking machines
refrigerators to milk
technical equipment
cowshed
Opis:
Przeprowadzone wśród dostawców mleka spółdzielni w Czarnkowie badania ankietowe dotyczyły stanu wyposażenia gospodarstw w urządzenia do doju i schładzania mleka. W 2003 roku rolnicy stosowali najczęściej dojarki rurociągowe (58,8%). Zmniejsza się też szybko liczba przestarzałych dojarek bańkowych i oceniono, że ich udział na koniec 2004 roku powinien wynosić 19,6%. Najlepiej przedstawia się stan wyposażenia gospodarstw w urządzenia do schładzania mleka. W 2003 roku w 84,6% przypadków stosowano schładzarki zbiornikowe, głównie typu otwartego. Stan ten powinien ulegać dalszej poprawie.
The poll of providers of milk to the cooperative in Czarnków was carried out. This research referred to the condition of the equipment of farms to devices for milking and refrigerating to milk. In 2003 farmers used the pipeline milking machines (58.8%) the most often. The number of out-of-date backet milking machines' is decreasing fast. Their participation in the end 2004 should be 19.6%. The condition of the equipment of farms to devices for refrigerating to milk presents the best. In 2003 to 84.6% of cases was used modern refrigerated bulk milk tanks, of mainly open type. This condition should improve in the future.
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 2 (77), 2 (77); 191-197
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies