Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "protetyka" wg kryterium: Wszystkie pola


Tytuł:
ZrO2-CeO2 ceramic powders obtained from a sol-gel process using acetylacetone as a chelating agent for potential application in prosthetic dentistry
Autorzy:
Nakonieczny, D.
Paszenda, Z.
Drewniak, S.
Radko, T.
Lis, M.
Powiązania:
https://bibliotekanauki.pl/articles/306436.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
proces zol-żel
metody rentgenowskie
analiza termiczna
ZrO2
protetyka
sol-gel process
X-ray Methods
Thermal Analysis
Prosthetic Dentistry
Opis:
Purpose: The main objective of this study was to obtain single-phase β-ZrO2 powders with so-called soft agglomerates reproducibile morphology with acetyl-acetone as a chelating-agent. To the best of our knowledge there is no avaiable data which determine the effect of acetyl acetone on the phase composition and morphology of ceria-doped ZrO2 powders for biomedical applications. Methods: Twenty variants of powders with different water to zirconia precursor and acetylacetone to zirconia precursor molar ratios were prepared. 0.9ZrO20.1CeO2 powders were obtained by a hydrolysis and condensation and further calcination of zirconium n-propoxide in a simple one-step sol-gel process. Influence of acetyloacetone to zirconia precursor on the phase composition ratio and water to zirconia precursor was investigated. Samples have been characterized by X-ray diffraction (XRD), Raman spectroscopy (RS), thermal analysis (TGA/DTA) and scanning electron microscopy (SEM) measurements. Results: Ceramic powders prepared by sol-gel process, according to the various concentration of chelating agent and water show different morphology and phase composition. Conclusions: Higher molar ratios of AcAc in range with smaller amounts of water cause hard agglomerates, obtained powders are characterized by highly thermally stable behaviour and various phase composition. With higher molar ratios of water to zirconium-n-propoxide so-called soft agglomerates and one phase powders are obtained.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 3; 53-60
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Znaczenie warunków podparcia i obciążenia w modelowych badaniach MES protez zębowych typu overdenture
Importance of support and loading conditions in overdenture FEM model investigations
Autorzy:
Żmudzki, J.
Chladek, G.
Powiązania:
https://bibliotekanauki.pl/articles/98749.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
proteza zębowa
MES (metoda elementów skończonych)
żucie
prosthodontics
dental prosthesis
FEM
mastication
Opis:
W badaniach modelowych FEM protez overdenture założenie więzów ograniczających ruchomość protezy w sposób zgodny z zasadami ich funkcjonowania pozwala na rozpoznanie obciążeń złączy, przy znacznym uproszczeniu modelu numerycznego. Dla powszechnie dostępnych w sprzedaży typów złączy podczas transmisji sił żucia stwierdzono występowanie znacznych wartości obciążeń bocznych, co stanowi bezpośrednie wyjaśnienie przyczyn niepowodzeń mechanicznych. Założenie pionowych kierunków sił zgryzowych prowadzi do znacznego niedoszacowania obciążeń złączy.
In overdenture FEM analysis, assumption of constrains reducing denture movement according to the rules of their functioning allows to determine loads of attachments, at the same time significantly simplifying numerical model. For commonly available types of attachments - during occlusal forces transmission found has been an occurrence of considerable lateral loads, which directly explains the causes of mechanical failures. Assumption of vertical occlusal forces directions leads to remarkable underestimating of attachments loads.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 239-245
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiana stężeń pierwiastków na granicy połączenia metal - ceramika w uzupełnieniu protetycznym
The change in elements construction an border of connection between a metal basis and ceramics in the prosthetic restoration
Autorzy:
Rogalińska, A.
Hajduga, M.
Powiązania:
https://bibliotekanauki.pl/articles/98686.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
proteza dentystyczna
uzupełnienie protetyczne
korona zęba
prosthodontics
dental prosthesis
prosthetic restoration
dental crown
Opis:
Temat pracy obejmuje ocenę charakteru połączenia metal- ceramika w konstrukcji protetycznej korony złożonej, licowanej ceramiką na podbudowie metalicznej. Praca określa cechy struktury metalicznej, którą bezpośrednio po odlaniu w masie osłaniającej chłodzono w bieżącej wodzie o temp. 15 °C. Wykonane badania ujawniły wady w strukturze metalicznej, zmianę stężeń pierwiastków, skład w poszczególnych miejscach próbki (w warstwie ceramicznej, metalicznej i na granicy połączenia metal-ceramika), przedstawiły obraz struktury i identyfikację składników strukturalnych oraz pozwoliły określić charakter połączenia pomiędzy dwoma fazami, tworzącymi uzupełnienie protetyczne.
The topic of the thesis includes the estimation of combination metal with ceramics in denture prosthesis crown, harmonized with ceramics on metal base. The thesis determines features of metal structure which directly after the casting in screnning substance cooled in running water. The research shown failures in metal structure, the change in elements construction, composition in particular places of the sample ( in ceramic and metal layer and on the boundry between them) shown the image of its structure and identification of structural ingredients and allowed to determine the combination between two phases creating the prosthetic restoration.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 193-200
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zestaw pomiarowy do badań diagnostycznych protez zębowych
Measuring system for diagnostics of dental prostheses
Autorzy:
Kuchta, M.
Kwiatos, K.
Fokow, K.
Powiązania:
https://bibliotekanauki.pl/articles/327460.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
protetyka stomatologiczna
diagnostyka
kinematyka protez
biomechanika stomatologiczna
system pomiarowy
dental prosthetics
diagnostics
dentures kinematics
dental biomechanics
measuring system
Opis:
Referat przedstawia metodę i układ pomiarowy do obiektywnej oceny jakości materiałów użytych do konstrukcji protez szczękowych jak również samej jej konstrukcji. Opracowany specjalizowany zestaw pomiarowy umożliwia wykonywanie szerokiego zakresu badań statycznych i dynamicznych, w ściśle określonych warunkach, na protezach zębowych.
The paper presents the method and measuring system for an objective assessment of materials used for the construction of prostheses and for the assessment of the constructions as well. The proposed system is capable of conducting wide range static and dynamic examinations of the prostheses.
Źródło:
Diagnostyka; 2006, 3(39); 187-192
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ technologii wytwarzania na właściwości materiałowe stopu kobaltu wykorzystywanego w protetyce dentystycznej
The effects of production technology on cobalt alloy material properties used in dental techniques
Autorzy:
Litwinko, M.
Grądzka-Dahlke, M.
Powiązania:
https://bibliotekanauki.pl/articles/99335.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
stop kobaltu
protetyka dentystyczna
odlewnictwo
SLM
cobalt alloy
prosthetic dentistry
foundry
Opis:
Jednym z etapów w procesie powstawania protetycznego uzupełnienia dentystycznego jest realizacja zaprojektowanego kształtu protezy w tworzywie metalowym. Jest krokiem istotnym a zarazem narażonym na wiele niepowodzeń. W artykule przedstawiono porównanie dwóch metod wykonawstwa techniki dentystycznej: tradycyjnego odlewania oraz nowoczesnej SLM. Badaniom poddano protetyczny stop kobaltu w postaci prostopadłościennych próbek.
One of the stages in the process of restoration of dental prostheses is the shape which was designed to achieve a complement in the metal. It is an important step and exposed to many setbacks. The article gives a comparison of two methods of dental technology: traditional casting and modern SLM. The test was in the form of a cobalt alloy prosthetic square bales samples.
Źródło:
Aktualne Problemy Biomechaniki; 2014, 8; 99-102
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości ścierne stopów Co-Cr w zawiesinie ceramika-sztuczna ślina
Abrasive behaviour of Co-Cr alloys in the ceramic material-artificial saliva suspension
Autorzy:
Augustyn-Pieniążek, J.
Kurtyka, P.
Stopka, J.
Powiązania:
https://bibliotekanauki.pl/articles/284452.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stopy Co-Cr
testy zużycia ściernego w zawiesinie
protetyka stomatologiczna
Co-Cr alloys
abrasive wear tests in suspension
prosthodontics
Opis:
Publikacja zawiera wyniki badań odporności na ścieranie stopów Co-Cr-Mo i Co-Cr-Mo-W przeprowadzonych na aparacie Millera. W celu oceny podatności na zużycie ścierne w naturalnych warunkach pracy w/w stopów, badania prowadzono w specjalnie zasymulowanym środowisku, składającym się z ceramicznego proszku Dentyna oraz roztworu sztucznej śliny o pH równym 6,7. W ramach badań przeprowadzono obserwacje mikrostruktury przy wykorzystaniu mikroskopu świetlnego stosując kontrast interferencyjno--różniczkowy (kontrast Nomarskiego), wykonano pomiary twardości, zaś powierzchnie po procesie ścierania poddano obserwacji przy wykorzystaniu elektronowej mikroskopii skaningowej. Na postawie przeprowadzonych badań stwierdzono, że stopy Co-Cr-Mo i Co-Cr-Mo-W charakteryzują się wysoką twardością około 400-450 HV10 i minimalnym ubytkiem masy w procesie ścierania. Cechy te świadczą o wysokiej odporności na ścieranie badanych stopów w środowisku proszek ceramiczny-sztuczna ślina. Dodatkowo stwierdzono również, że trzy z badanych stopów Remanium 2001, Colado CC oraz Heraenium P w odróżnieniu od stopu Wironit LA, posiadają przystanki na krzywych ubytku masy w czasie związane z różnicami twardości materiału osnowy β-Co, wydzieleń węglikowych oraz ramion dendrytów. W przypadku stopu Wironit LA obserwowano równomierne zużycie materiału na całej powierzchni. Stwierdzono również, że pomimo różnic w mechanizmach ścierania pomiędzy stopem Wironit LA I Remanium 2001 wielkość ubytku masy jest dla nich na podobnym poziomie, jednak jest ona znacznie niższa niż dla pozostałych dwóch badanych stopów Colado CC ora Heraenium P.
The publication contains the results of the abrasion resistance tests carried out on Co-Cr-Mo and Co-Cr--Mo-W alloys using Miller apparatus. To assess the susceptibility to abrasive wear of the above mentioned alloys under natural operating conditions, tests were carried out in a specially simulated environment, consisting of a ceramic Dentine powder and artificial saliva solution with pH of 6.7. The scope of studies included the examinations of microstructure performed by light microscopy using differential interference contrast (Nomarski contrast), measurements of hardness, and SEM examinations of surfaces after the abrasion process. The results of these studies enabled formulating the conclusion that alloys from the Co-Cr-Mo and Co-Cr-Mo-W systems are characterised by high hardness of about 400-450 HV10 and minimum weight loss in the process of abrasion. These features prove high abrasive wear resistance of the examined alloys in the environment of ceramic powder and artificial saliva. Additionally, it was also found that three of the tested alloys, i.e. Remanium 2001, Colado CC and Heraenium P, unlike the Wironit LA alloy, show time-related arrests on the weight loss curves caused by different hardness values of the β-Co matrix, carbide precipitates and dendrite arms. The Wironit LA alloy was observed to wear evenly across the whole surface. It was also found that, despite differences in abrasion mechanism operating in the Wironit LA and Remanium 2001 alloys, the magnitude of weight loss has been similar and, at the same time, much lower than for the other two alloys tested, i.e. Colado CC and Heraenium P.
Źródło:
Engineering of Biomaterials; 2014, 17, 127; 7-15
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
What can normal gait biomechanics teach a designer of lower limb prostheses
Autorzy:
Pitkin, M.
Powiązania:
https://bibliotekanauki.pl/articles/306996.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biomechanics
prosthetics
anthropomorphicity
biomechanika
protetyka
Opis:
Compensating a limb loss with prosthesis is a challenging task due to complexity of the human body which cannot be fully matched by the available technical means. Designer of lower limb prostheses wants to know what specification of the device could provide the best approximation to the normal locomotion. Deep understanding of the latter is essential, and gait analysis may be a valuable tool for this. Once prosthesis is built, gait analysis may help in comparing the wearer’s performance with the new device and with the prior art, and in verification of the hypotheses being put forward during the development process. In this lecture, we will discuss some synergies of normal gait. We will focus on the required biomechanical properties of a prosthetic leg that can allow the prosthesis’s inclusion in normal gait synergy without demanding excessive compensatory movements. We will consider contribution of leg joints to generation of propulsion for adequate design of lower limb prostheses especially those with power supply.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 1; 3-10
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The role of friction in the mechanism of retaining the partial removable dentures with double crown system
Autorzy:
Dąbrowa, T.
Dobrowolska, A.
Wieleba, W.
Powiązania:
https://bibliotekanauki.pl/articles/306716.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dental crown
friction
prosthodontic materials
korona protetyczna
protetyka stomatologiczna
materiały stomatologiczne
Opis:
Cylindrical telescopic crowns belong to bolt dentures, because their adhesion strength is based on the friction force. The magnitude of static and slide friction forces depends on the strain within the contact area and properties of materials employed. Friction force value between telescope elements declines in the first phase of wearing period and, subsequently, maintains particular constant value of 8 to 10 N. In the telescopic technique, homo and heterogenic joints are used. The following prosthodontic materials have been examined: goldbase alloys (Degudent Kiss, Degulor M), cobalt-base alloy (Brealloy 270), ceramics (Zircon Oxide, Zirconia) during tribological investigations on FGP composite resin. The cooperating surfaces were moistened with synthetic saliva. The research confirmed the dependence of the static friction coefficient on the contact pressure for the analyzed pairs of materials used in prosthodontics. The biggest effect of the contact pressure on the coefficient of friction value occurs when the ceramic rubs on FGP composite resin. The most stable friction coefficient in the context of contact pressure changes as well as life has been found in the case of the cobalt alloy Brealloy 270. An interesting material is a gold alloy Degulor M, for which the coefficient of friction varies only slightly with pressure in the range of 0.6 to 0.9 MPa.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 4; 43-48
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of saliva and its substitutes on corrosion of some implant alloys
Autorzy:
Andrysewicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/387260.pdf
Data publikacji:
2013
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
metallic alloys
corosion
human saliva
saliva substitute
prosthodontia
stopy metalu
korozja
ludzka ślina
substytut śliny
protetyka stomatologiczna
Opis:
The purpose of this paper is evaluation of the influence of human saliva and its substitutes on the corrosion re sistance of some implant alloys used in stomatology, which included: austenitic steel (316L), titanium alloy (Ti6Al4V), and cobalt alloy (CoCrMo). Corrosion studies were conducted by means of the potentiodynamic method with the application of the VoltaLab 21 kit with VoltaMaster 4 software. The reference electrode was a saturated calomel electrode (SCE), whereas the counter electrode was a platinum electrode. The results of conducted studies indicate an increased current density in the passive range on potentiodynamic curves of studied alloys in the envi- ronment of human saliva, and also in a commercial saliva solution – Mucinox. On the basis of conducted corrosion studies, it can be stated that in terms of corrosion resistance the developed saliva substitutes may constitute competitive solutions to commercial saliva substitutes. The prepared substitutes should be studied further from the perspective of practical application for patients. The original value of the paper is a proposition of new saliva substitutes.
Źródło:
Acta Mechanica et Automatica; 2013, 7, 2; 69-74
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Remelting on the Quality of Prosthetic Cobalt Alloys
Autorzy:
Nadolski, M.
Łągiewka, M.
Konopka, Z.
Zyska, A.
Golański, G.
Powiązania:
https://bibliotekanauki.pl/articles/382647.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cobalt alloy
centrifugal casting
lost wax technology
dental prosthetics
stop kobaltu
odlewanie odśrodkowe
metoda wytapianych modeli
protetyka stomatologiczna
Opis:
A commercial cobalt alloy applied in dental prosthetics was investigated. The scope of the work included the microstructure analysis, performance examination (tensile strength, microhardness, corrosion resistance), and dilatometric examination. The investigated alloy after a single remelting was characterised by higher tensile strength and hardness. There were not found the definite results with regard to the corrosion resistance of the examined materials. No significant change occurred in the coefficient of thermal expansion.
Źródło:
Archives of Foundry Engineering; 2015, 15, 3 spec.; 53-58
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Struktura i własności mechaniczne modyfikowanych stopów CoCrMo do zastosowań w protetyce stomatologicznej
Structure and mechanical properties of modified CoCrMo alloys for use in dental prosthetics
Autorzy:
Beer, K.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/285534.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
protetyka stomatologiczna
biomateriały
stopy CoCrMo
dental prosthetics
biomaterials
Co-Cr-Mo alloys
Opis:
Większość klinicznych niepowodzeń w przypadku protez stomatologicznych związana jest przede wszystkim z techniką wytapiania i odlewania oraz ilością użytego do wsadu stopu już raz przetopionego. W pracy dokonano analizy wpływu ilości materiału z recyklingu na właściwości mechaniczne i strukturę stomatologicznego stopu CoCrMo. Zastosowano metodę odlewania odśrodkowego, oraz jednokrotne przetopy o składzie wyjściowym odpowiednio 0, 25, 50, 75 i 100% złomu. Przeprowadzono statyczną próbę rozciągania, pomiar mikrotwardości, analizę mikrostrukturalną oraz obserwację SEM przełomów. Stwierdzono, że własności mechaniczne wszystkich przetapianych stopów są gorsze niż stopu czystego, zakupionego u zagranicznego producenta. Mikrostruktura przełomów przetapianych stopów z zawartością złomu powyżej 50% jest bardziej niejednorodna i w strukturze dendrytycznej widoczna jest większa ilość mikropęknięć. Podczas zrywania próbek zarejestrowano wyraźne obniżenie granicy plastyczności i wytrzymałości tych stopów w próbach zrywania w porównaniu z próbkami ze stopów zawierających mniejszą ilość materiału z recyklingu.
The majority of clinical failures in the case of dental prostheses is associated primarily with the technique and the amount of remelted alloy used for the casting. The majority of clinical failures in the case of dental prostheses is associated primarily with the technique of remelting and casting, and quantity of the once remelted alloy used for the batch. The paper analyzes the impact of the amounts of recycled material on the mechanical properties and structure of dental alloy CoCrMo. The centrifugal casting method has been applied and remelted alloys with output composition of 0, 25, 50, 75 and 100% of scrap respectively. The static tensile test, microstructural analysis and SEM observation as well as microhardness test have been conducted. These all tests show that the mechanical strength of all remelted alloys is worse than the strength of the fine alloy, purchased from a foreign manufacturer. The microstructure of breakthroughs of the remelted alloys containing more than 50% of scrap is more heterogeneous and a higher amount of microcracks is visible in the dendritic structure. When the samples were tested in the static tension test, the significant decrease in the yield strength and the tensile strength of these alloys during these static tension tests in comparison to the samples of alloys containing lower amount of the recycled material were observed.
Źródło:
Engineering of Biomaterials; 2011, 14, no. 106-108; 110-115
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected properties and tribological wear alloys Co-Cr-Mo and Co-Cr-Mo-W used in dental prosthetics
Wybrane właściwości oraz zużycie tribologiczne stopów, Co-Cr-Mo i Co-Cr-Mo-w stosowanych w protetyce stomatologicznej
Autorzy:
Augustyn-Pieniążek, J.
Kurtyka, P.
Sulima, I.
Stopka, J.
Powiązania:
https://bibliotekanauki.pl/articles/356345.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Co-Cr alloys
wear
slurry abrasion test (“Miller test”)
dental prosthetics
Co-Cr stopy
zużycie
badanie zużycia ściernego stopów
aparat Millera
protetyka stomatologiczna
Opis:
The presented work provides the results of the abrasive wear resistance tests performed on Co-Cr-Mo and Co-Cr-Mo-W alloys with the use of the Miller’s apparatus. The analyzed alloys underwent microstructure observations as well as hardness measurements, and the abraded surfaces of the examined materials were observed by means of electron scanning microscopy. The performed examinations made it possible to state that the Co-Cr alloys characterized in a high hardness, whereas the changes in the mass decrement were minimal, which proved a high abrasive wear resistance.
W prezentowanej pracy przedstawiono wyniki badań zużycia ściernego stopów, Co-Cr-Mo i Co-Cr-Mo-W przy użyciu aparatu Millera. Analizowane stopy poddano obserwacjom mikrostruktury, pomiarom twardości i mikrotwardości, a ścierane powierzchnie badanych materiałów obserwacji przy wykorzystaniu elektronowej mikroskopii skaningowej. Przeprowadzone badania pozwoliły na stwierdzenie, że stopy, Co-Cr charakteryzowały się wysoką twardością i mikrotwardością, zaś zmiany ubytku masy były bardzo minimalne, co świadczy o wysokiej odporności na ścieranie.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3A; 1569-1574
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Qualitative Assessment of the Defects in Metal Casting Prosthetic Restorations
Autorzy:
Augustyn-Pieniążek, J.
Wilkosz, K.
Powiązania:
https://bibliotekanauki.pl/articles/379721.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cobalt based alloys
casting defects
dental prosthetics
3D scanner
kobalt
wady odlewnicze
protetyka stomatologiczna
skaner 3D
Opis:
Due to the frequent occurrence of casting defects in the casting process of metal prosthetic elements, studies aiming at identifying the defects and determining their probable causes were performed. The work presents the results of the examinations of the Co-Cr-Mo alloy, brand name Argeloy N.P. Special, used for prosthetic restorations. Macroscopic and microscopic observations were conducted with the use of light and scanning microscopy (SEM). Also, the results of the observations by means of a 3D scanner by GOM ATOS 3 were presented. The performed research made it possible to determine and classify casting defects such as blisters, misruns and interscrystalline cracks. It was stated that a stabilized technological process affects the elimination of the casting defect formation.
Źródło:
Archives of Foundry Engineering; 2014, 14, 4 spec.; 7-12
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies