Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power supply circuits" wg kryterium: Wszystkie pola


Wyświetlanie 1-6 z 6
Tytuł:
A 65 nm CMOS Resistorless Current Reference Source with Low Sensitivity to PVT Variations
Autorzy:
Łukaszewicz, M.
Borejko, T.
Pleskacz, W. A.
Powiązania:
https://bibliotekanauki.pl/articles/397920.pdf
Data publikacji:
2012
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
efekt objętościowy
obwody zasilające
napięcie progowe
current reference
65 nm CMOS
body effect
power supply circuits
threshold voltage
Opis:
This paper describes a resistorless current reference source, e.g. for fast communication interfaces. Addition of currents with opposite temperature coefficient (PTC and NTC) and body effect have been used to temperature compensation. Cascode structures have been used to improve the power supply rejection ratio. The reference current source has been designed in a GLOBALFOUNDRIES 65 nm technology. The presented circuit achieves 59 ppm/°C temperature coefficient over range of -40°C to 125°C. Reference current susceptibility to process parameters variation is ± 2.88%. The power supply rejection ratio without any filtering capacitor at 100 Hz and 10 MHz is lower than -142 dB and -131 dB, respectively.
Źródło:
International Journal of Microelectronics and Computer Science; 2012, 3, 4; 119-124
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Single phase UPS systems loaded with nonlinear circuits: analysis of topology in the context of electric power quality
Autorzy:
Szulborski, Michał
Kolimas, Łukasz
Łapczyński, Sebastian
Szczęśniak, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/140626.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical measurement
harmonic distortion
nonlinear circuits
uninterruptible power supply
Opis:
Along with the increase in the use of nonlinear electronic devices, e.g. personal computers, power tools and other electrical appliances, the requirements for uninterruptible power supplies are constantly growing. This paper proposes a method and deep analysis of results viable for checking how single-phase uninterruptible power supplies (UPSs) cope with nonlinear circuits under varying power loads in terms of electric energy quality. Various classes of single-phase UPS systems with different topologies were tested, for instance line-interactive and double conversion (online) single-phase UPS devices. Furthermore, measurements were carried out in view of a power source – loads were supplied both from a power grid and UPS built-in battery. Juxtaposition of the obtained results such as a THDU , THDI (Total Harmonic Distortion) percentage ratio of input/output voltage and current, a power factor and crest factor volume etc. of the tested UPS systems indicated major differences in their performance during laboratory tests.
Źródło:
Archives of Electrical Engineering; 2019, 68, 4; 787-802
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reactive power compensation in a three-phase power supply system in an electric vehicle charging station
Autorzy:
Zajkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/95374.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
power compensation
reactive power
three-phase circuits
unbalanced system
nonlinear receiver
kompensacja mocy
moc bierna
obwód trójfazowy
układ niezrównoważony
odbiornik nieliniowy
Opis:
The article presents the problem of reactive power compensation in an electric network, which powers a charging station for electric vehicles. The reactive power is present because the converters have a reactance character. Mobile inverters are single-phase receivers, so they cause a lack of symmetry in a three-phase system. Lack of symmetry causes an unbalance component to appear. The power compensation discussed here results in an improvement in the power factor. The reduction of the reactive and unbalance power is the result of this compensation. The article takes into account a non-sinusoidal method of power supply.
Źródło:
Journal of Mechanical and Energy Engineering; 2018, 2, 1; 75-84
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zapewnienie iskrobezpieczeństwa systemów zdalnego zasilania przez zastosowanie układów ochronnych z nieliniową charakterystyką wyjściową
Ensuring the intrinsic safety remote power supply systems be means of application of protective circuits having non-linear output characteristics
Autorzy:
Skoropacki, W.
Powiązania:
https://bibliotekanauki.pl/articles/340434.pdf
Data publikacji:
2005
Wydawca:
Główny Instytut Górnictwa
Tematy:
iskrobezpieczeństwo
obwód elektryczny
separacja energetyczna
intrinsic safety
power supply system
energetic separation
Opis:
Iskrobezpieczeństwo obwodu elektrycznego może być zapewnione następującymi sposobami: - przez ograniczenie prądu i napięcia w punkcie komutacji awaryjnej, powstałym w dowolnym miejscu w obwodzie chronionym, - przez ograniczenie szybkości zmiany napięcia w punkcie komutacji awaryjnej, - za pomocą separacji energetycznej źródła zapłonu. Najprostszym sposobem realizacji pierwszego sposobu jest zastosowanie szeregowego rezystora ograniczającego. Wadą tego sposobu jest brak stabilizacji napięcia na wejściu iskrobezpiecznego obwodu elektrycznego oraz niska wartość iskrobezpiecznej mocy odbieranej od źródła zasilania z ograniczającym rezystorem wyjściowym. Separacja energetyczna źródła zapłonu (np. źródła zasilania) jest najbardziej efektywnym sposobem zapewnienia iskrobezpieczeństwa przy powstaniu komutacji awaryjnej w obwodzie elektrycznym. Sposób ten polega na ograniczeniu trwania wyładowania elektrycznego. Charakterystyka wyjściowa układu ochronnego jest przy tym nieliniowa. Równocześnie przy jednakowej mocy maksymalnej, którą źródło może oddać obciążeniu, trwanie wyładowania i wydzielona energia będą mniejsze niż przy stosowaniu układu ochronnego z charakterystyką liniową, tzn. z ograniczającym rezystorem wyjściowym. Jednym ze sposobów realizacji nieliniowej charakterystyki wyjściowej układu ochronnego jest energetyczna separacja obwodu chronionego (odłączenie źródła zasilania). Energetyczna separacja (odłączenie) źródła zasilania przy komutacji awaryjnej jest najmniej skomplikowanym i najbardziej efektywnym sposobem zapewnienia iskrobezpieczeństwa obwodów elektrycznych przez ograniczenie trwania rozładowania. Odłączenie źródła zasilania może być zrealizowane w następujący sposób: - przez ciągłą kontrolę parametrów obwodu elektrycznego i odłączenie źródła zasilania w przypadku, kiedy te parametry przekroczą wartości dopuszczalne, - przez kontrolę stanu pracy obwodu elektrycznego i odłączenie źródła zasilania, przy przekroczeniu dopuszczalnej wartości prądu lub napięcia, - przez kontrolę szybkości zmian prądu i napięcia w obwodzie elektrycznym i odłączenie źródła zasilania przy przekroczeniu wartości pochodnej od prądu lub napięcia ustalonego prądu. Odłączenie źródła zasilania najczęściej jest stosowane przy przekroczeniu wartości progowej prądu w obwodzie. Ta metoda umożliwia kilkakrotne zwiększenie mocy iskrobezpiecznej obciążenia w stosunku do źródła zasilania z liniową charakterystyką wyjściową. Realizacja techniczna takiego układu ochronnego polega na stosowaniu kluczy zwierających z wykorzystaniem tyrystorów. Badania zapalności obwodów elektrycznych z wymienionymi układami ochronnymi nie mogą być prowadzone z wykorzystaniem typowego iskiemika. Estymacji wartości energii można dokonać na podstawie: obliczeń analitycznych, symulacji komputerowej, np. z wykorzystaniem programu PSPICE, pomiarów oscyloskopowych. Metoda oscyloskopowa w tym przypadku jest najbardziej perspektywiczną alternatywą. Stosowanie układu ochronnego z nieliniową charakterystyką dokonującego odłączenia źródła zasilania przez zwarcia zacisków wyjściowych źródła zasilania, w chwili powstania komutacji awaryjnej, wymaga opracowania i realizacji technicznej algorytmów współpracy między tym układem a źródłem zasilania oraz odbiornikiem energii elektrycznej. Wymagana jest także realizacja "miękkiego" startu włączenia i odbioru energii elektrycznej.
The intrinsic safety of electric circuits can be ensured by the following means: - limitation of current or voltage at the emergency commutation point anywhere in the circuit being protected, - limitation of voltage changes rate at the emergency commutation point, - energetic separation of the ignition source. The simplest way to implement the first method is the application of a limiting resistor in series, though this solution has its drawbacks, namely there is lack of voltage stabilization at the protective circuit input and the intrinsic safety power taken over from the power source with the limiting output resistor is low. The energetic separation of the ignition source (for example the power source) is the most effective method to ensure intrinsic safety when an emergency commutation arises in the electric circuit. This method consists in limitation of electrical discharge duration time. Output characteristics of the protective circuit is non-linear in this case, and for the same amount of maximal power that can be transferred into the load by the power source, both the discharge duration time and the energy produced would be lower than in the protective circuits of linear characteristics, i.e. with a limiting output resistor. One of the means of realization of non-linear output characteristics of protective circuit is the energetic separation of the circuit being protected (i.e. disconnection of the power source). The energetic separation (disconnection) of the power source during emergency commutation is the simplest and most effective way of securing intrinsic safety for electric circuits by reduction of discharge duration time. Disconnection of the power source can be realized in the following ways: - constant monitoring of parameters of the electric circuit and interruption of power supply when the permissible values of these parameters are exceeded, - monitoring of the state of the circuit and disconnection of power supply when the permissible values of voltage or current are exceeded, - monitoring of rates of change of voltage and current in the circuit and disconnection of power supply when the derivative of voltage or current exceeds certain values. Disconnection of power supply is frequently used when current in the circuit exceeds the threshold value. This method enables to achieve the values of intrinsic safety power of load several times higher in comparison with power supply systems having linear output characteristics. Technical realization of such protective circuits consist in application of short-circuiting keys with the use of thyristors.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2005, 4; 99-114
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic tuning of a resonant circuit in wireless power supply systems for biomedical sensors
Autorzy:
Blakiewicz, G.
Jakusz, J.
Jendernalik, W.
Szczepański, S.
Powiązania:
https://bibliotekanauki.pl/articles/201440.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CMOS circuits
automatic tuning
impedance matching
resonant circuit
układy CMOS
tuning
impedancja
obwód rezonansowy
Opis:
In this paper, a tuning method of a resonant circuit suited for wireless powering of miniature endoscopic capsules is presented and discussed. The method allows for an automatic tuning of the resonant frequency and matching impedance of a full wave rectifier loading the resonant circuit. Thereby, the receiver tunes so as to obtain the highest power efficiency under given conditions of transmission. A prototype receiver for wireless power reception, fabricated in in AMS CMOS 0.35 μm technology, was used to verify correct operation of the proposed tuning. The prototype system produces a stable supply voltage, adjustable in the range of 1.2–1.8 V at a maximum output current of 100–67 mA, which is sufficient to power a typical endoscopic capsule.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 3; 641-646
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zależności energetyczne przy zapewnieniu iskrobezpieczeństwa obwodów elektrycznych typu RC za pomocą układów ochronnych o nieliniowej charakterystyce wyjściowej
Energy relations at assurance of spark-proofness of RC type electric circuits with the use of protective systems with non-linear output characteristics
Autorzy:
Skoropacki, W.
Powiązania:
https://bibliotekanauki.pl/articles/340238.pdf
Data publikacji:
2006
Wydawca:
Główny Instytut Górnictwa
Tematy:
iskrobezpieczeństwo
obwód elektryczny
dyrektywa 94/9/WE
układ nieliniowy
układ ochronny
źródła energii
zasilanie
spark-proof safety
electric circuit
94/9/WE directive
nonlinear system
protective system
power supply
Opis:
Według dyrektywy Parlamentu Europejskiego i Rady 94/9/WE (ATEX 100A), poziom iskrobezpieczeństwa "ia", nie może być uzyskany za pomocą stosowania sterowanych elementów półprzewodnikowych jako szeregowych ograniczników prądu. Stosowanie tych elementów natomiast jest dozwolone w postaci równoległych ograniczników napięcia jako zwierników zacisków wyjściowych źródła zasilania. Układ ochronny obwodu iskrobezpiecznego, zbudowany na tej zasadzie, ma nieliniową charakterystykę wyjściową. Z tej przyczyny aktualne staje się badanie efektywności zapewnienia iskrobezpieczeństwa układów ochronnych o nieliniowej charakterystyce wyjściowej z wykorzystaniem zależności energetycznych w okresie przejściowym. W artykule zostało przedstawione to zagadnienie w zakresie analizy wydzielania energii w kanale wyładowania elektrycznego wskutek komutacji awaryjnej typu zwarcie w obwodzie RC. Do analizy tej energii wykorzystano kilka matematycznych modeli zmiany rezystancji kanału wyładowania - liniowej i nieliniowych. Stwierdzono, że wydajność energetyczna procesu wyładowania, stanowiąca procentowy udział energii elektrycznej pochłanianej w kanale wyładowania w stosunku do pierwotnej energii zgromadzonej w kondensatorze, jest maksymalna dla liniowego modelu zmiany rezystancji kanału wyładowania elektrycznego oraz w początkowym okresie procesu wyładowania i przy minimalnej szybkości zmiany rezystancji kanału wyładowania elektrycznego. Efekt znaczącej redukcji energii pochłanianej w kanale wyładowania osiąga się w przypadku stosowania nieliniowego układu elektronicznego, zwierającego punkt iskrowego rozładowania kondensatora z jak najkrótszym opóźnieniem w stosunku do początku powstania procesu rozładowania, przy czym potencjalna wartość tej redukcji nie przewyższa 50% w przypadku stosowania progowych układów zabezpieczenia nadprądowego. Wykazano, że rezystor szeregowo włączony w obwód rozładowania kondensatora staje się skuteczny, pod względem redukcji energii wydzielanej w kanale wyładowania, dla wartości tego rezystora powyżej 10 Ω, przy czym efekt redukcji nie jest stały dla kondensatorów o różnej pojemności. Z kolei, włączenie dodatkowego rezystora w przypadku zastosowania nieliniowego układu ochronnego zmniejsza w sposób wyraźny wartość energii elektrycznej wydzielanej w kanale wyładowania. Istotne zmniejszenie tej energii osiąga się już przy wartości dodatkowego rezystora wynoszącej kilka omów. To oznacza, że zastosowanie nieliniowych układów ochronnych jest korzystniejsze niż z konwencjonalnych liniowych układów ochronnych, ponieważ w licznych przypadkach obecność takiego rezystora o dużej wartości koliduje z przeznaczeniem kondensatora, na przykład kiedy kondensator jest wykorzystywany jako element filtru wygładzającego.
According to the directive of European Parliament and Council 94/9/WE (ATEX 100A), level "ia" of sparkproofness, it can not be obtained with the use of applying of steered semiconducting elements as serial current limiters. However, applying of these elements is permissible in form of voltage parallel limiters, as short circuiting switches of output terminals of power supply. Protective system of sparkproof circuit, built according to this rule, possess a non-linear output characteristics. Because of this, efficiency tests of sparkproofness assurance using energy relations for a transitory period become a live issue for the protective systems with non-linear output characteristics. In the paper, this question was presented in the scope of analysis of energy releasing in channel of electric discharge resulting from emergency commutation of the short-circuit type in circuit RC. Some mathematical models of channel discharge resistance change, linear and non-linear, were used for analysis of this energy. It was stated that an energetic efficiency of discharge process, constituting proportional part of electric energy absorbed in discharge channel in relation to prime energy accumulated in capacitor, is maximal for a linear model of resistance change of electric discharge channel, as well as in an initial period of discharge process and at minimal rate of resistance change of electric discharge channel. Effect of significant reduction of energy absorbed in the discharge channel is achieved in the case of applying of non-linear electronic system short-circuiting the point of sparkle discharge of capacitor within the shortest possible delay in relation to beginning of rise of the discharging process. At the same time, the potential value of this reduction is not higher than 50%, in the case of threshold systems applying for excess current protection. It was shown, that resistor included in series in a capacitor discharging circuit becomes effective, with regard to reduction of energy releasing in channel of discharge, for values of its resistance above 10 Ω , and the effect of reduction is not constant for capacitors of different capacities. Subsequently, inclusion of an additional resistor diminishes significantly the value of electric energy releasing in the channel of discharge in the case of use of the non-linear protective system. Essential decrease of this energy is achieved already at additional resistance value of few ohms. This means that use of non-linear protective systems is more advantageous than the use of conventional linear protective systems, because in numerous cases the presence of such a resistor of large value interferes with a capacitor destination, for example when the capacitor is used as an element of smoothing filter.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2006, 4; 63-76
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies