Design of thermoelectric radiant cooling – photovoltaic panels system in the building
Autorzy:
Abdulghafor, Israa Ali
Mnati, Mohannad Jabbar
Powiązania:
https://bibliotekanauki.pl/articles/2204065.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermoelectric panel
cooling capacity
numerical calculations
PV system
Opis:
In this study, a theoretical model is presented to investigate the performance of a thermoelectric (TE) radiant cooling system combined with photovoltaic (PV) modules as a power supply in a building with an ambient temperature reaching more than 45◦C. The combined system TE/PV performance is studied under different solar radiation by using the hourly analysis program and photovoltaic system software. The thermal and electric characteristics of TE are theoretically investigated under various supplied voltages using the multi-paradigm programming language and numerical computing environment. Also, a theoretical analysis of heat transfer between the TE radiant cooling system and an occupied zone from the side, and the other side between the TE radiant cooling system and duct zone is presented. The maximum power consumption by TE panels and building cooling load of 130 kW is predicted for May and June. The 145 units of PV panels could provide about 50% of the power required by TE panels. The thermal and electric characteristics of TE panels results show the minimum cold surface temperature of 15◦C at a supplied voltage between 6 V and 7 V, and the maximum hot surface temperature of 62◦C at a supplied voltage of 16 V. The surface temperature difference between supplied current and supplied power increases as supplied voltage increases. At a higher supplied voltage of 16 V, the maximum surface temperature difference between supplied current, and supplied power of 150◦C, 3.2 A, and 48 W, respectively. The cooling capacity increases as supplied voltage increases, at a surface temperature difference of –10◦C and supplied voltage of 16 V, the maximum cooling capacity is founded at about 60 W. As supplied voltage decreases the coefficient of performance increases. The maximum coefficient of performance is about 5 at the surface temperature difference of –10◦C and supplied voltage of 8 V.
Źródło:
Archives of Thermodynamics; 2022, 43, 4; 85--108
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja systemu sterowania instalacji fotowoltaicznej
Conception of control system installation photovoltaic
Autorzy:
Dziubiński, M.
Siemionek, E.
Adamiec, M.
Drozd, A.
Mazurkiewicz, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/315383.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
panel fotowoltaiczny
układ fotowoltaiczny
system sterowania
photovoltaic panel
photovoltaic system
control system
Opis:
W artykule przedstawiono wyniki eksperymentalnych badań na dwóch zaprojektowanych i wykonanych układach sterowania paneli fotowoltaicznych. Zaprojektowany i wykonany model umożliwia przeprowadzenie analizy wpływu wybranych parametrów sterowania na uzyskiwaną energię z paneli fotowoltaicznych. W artykule przedstawiono koncepcję fotowoltaicznego układu hybrydowego. Nowością rozwiązania jest układ sterowania umożliwiający zmianę kąta nachylenia paneli słonecznych względem podłoża i kąta obrotu. Otrzymane wyniki z pomiarów potwierdziły funkcjonalne możliwości systemu sterowania.
The article presents the results of the experimental studies designed and built control system of photovoltaic panels. The designed and executed model enables analysis of the influence of selected control parameters on the obtained energy from photovoltaic panels. A novel solution is the control system that allows the sun angle to be adjusted relative to the ground and the angle of rotation. The results obtained from the measurements confirm the functional capabilities of the control system.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 853-856, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estetyka i efektywność w polskiej przestrzeni architektonicznej w aspekcie instalacji solarnych i fotowoltaicznych
Aesthetics and Efficiency in the Polish Architectural Spaces in the Aspect of Solar and Photovoltaic Installations
Autorzy:
Felski, Bartosz
Pęczek, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/2021090.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Architectural aesthetics
energy efficiency in architecture
PV panels
solar panel
Źródło:
Studia komitetu przestrzennego zagospodarowania kraju PAN; 2018, 187; 284-293
0079-3507
Pojawia się w:
Studia komitetu przestrzennego zagospodarowania kraju PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania eksploatacyjne struktur fotowoltaicznych zamocowanych na pokładzie autobusu miejskiego z silnikiem diesla
The research on the operation of on-board photovoltaic structures installed in a city bus with a diesel engine
Autorzy:
Gęca, M.
Wendeker, M.
Grabowski, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/133861.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
panel PV
silnik diesla
zużycie energii elektrycznej
photovoltaic panel
diesel engine
electric energy consumption
Opis:
W artykule przedstawiono wyniki badań eksploatacyjnych systemu elastycznych paneli fotowoltaicznych za-mocowanych na dachu autobusu miejskiego. W ciągu dnia system PV zasila elektryczne odbiorniki i doładowuje akumulatory. Obiektem badań był autobus miejski Mercedes Conecto 12LF wyposażony w silnik o zapłonie samoczynnym spełniający normę Euro IV. Badania zawierające różne trasy w Lublinie przeprowadzono w ciągu całego roku. Przedstawiono szczegółowe wyniki badań zużycia energii elektrycznej przez autobus. Równolegle pomiary trwały na stanowisku stacjonarnym wyposażonym w takie same panele PV. Pomiary wartości nasłonecznienia i ilości generowanej energii elektrycznej na dachu autobusu porównano z wartościami uzyskanymi ze stacjonarnego stanowiska. System fotowoltaiczny zamontowany na dachu autobusu odbiera średnio w ciągu roku o 18,9% mniej energii słonecznej, niż ten sam system zamontowany na dachu budynku. Bilans energii elektrycznej potwierdzony badaniami rzeczywistymi potwierdził, że 28% zużycia energii elektrycznej na pokładzie autobusu miejskiego może zostać zastąpione energią ze słońca. Prowadzi to do zmniejszenia zużycia paliwa o około 3% i emisji CO2 o około 1,8 t rocznie.
This paper presents the results on the operation of the system of flexible photovoltaic panels installed on a roof of a city bus. Over day operation, the PV system supplies electricity to electrical receivers and recharges batteries. The research was done for the Mercedes Conecto 12LF city bus fitted with a Euro IV standard diesel engine. The research covered various routes in Lublin over the year. The paper presents detailed electricity consumption in the bus which was accompanied by parallel electricity consumption measurements done on a stationary test stand with identical PV panels. The results on solar radiation and electricity generated on the roof of the bus were compared with those obtained from the stationary test stand. Over the year, the photovoltaic system installed on the roof of the bus received on average by 18,9% solar energy less than the identical system installed on a roof of a building. The energy balance which was supported by real research confirmed that 28% of on-board electricity consumption in a city bus can be replaced by solar energy, which leads to a reduced fuel consumption by about 3% and CO2 emissions by about 1.8 tons per year.
Źródło:
Combustion Engines; 2015, 54, 3; 498-503
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza opłacalności inwestowania w przydomowe instalacje fotowoltaiczne na przykładzie paneli i dachówek fotowoltaicznych
Economic analysis of photovoltaic panel and roofing tile for domestic use
Autorzy:
Głów, A.
Kurz, D.
Powiązania:
https://bibliotekanauki.pl/articles/377315.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
panel fotowoltaiczny
dachówka solarna
PV
BIPV
przydomowa instalacja fotowoltaiczna
Opis:
W pracy dokonano porównania danych technicznych tradycyjnego panelu fotowoltaicznego oraz dachówki solarnej. Dla wybranego przykładowego domu jednorodzinnego przeprowadzono analizę kosztów instalacji złożonej z obydwu rodzajów ogniw PV, oszacowano uzysk energii oraz czas zwrotu inwestycji. Wskazano możliwości uzyskania dofinansowania dla inwestycji w obszarze przydomowych instalacji fotowoltaicznych dla osób fizycznych.
This paper presents a comparison of the specifications of the traditional photovoltaic panel and solar roof tiles. For the selected sample of a single-family house was analyzed costs installation consisting of both types of PV cells, estimated energy yield and return on investment. Indicated the possibility of obtaining funding for investment in the domestic photovoltaic installations for individuals.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 74; 275-282
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza opłacalności inwestycji w źródła fotowoltaiczne
The comparative analysis of the profitability of investments in the renewable energy source
Autorzy:
Głuchy, D.
Powiązania:
https://bibliotekanauki.pl/articles/408271.pdf
Data publikacji:
2012
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
panel fotowoltaiczny
analiza porównawcza
instalacja PV
photovoltaic panel
comparative analysis
PV installation
Opis:
Przedstawiono trzy różne rodzaje instalacji opartych na odnawialnych źródłach umożliwiających wytwarzanie energii elektrycznej. Dokonano porównania parametrów technicznych wybranych rozwiązań. Dla wybranych urządzeń generujących energię obliczono jej wartość. Gotowe wyniki mogą pomóc inwestorowi podjąć decyzję o wyborze odpowiedniego dla siebie rozwiązania.
The paper presents three different types of installations based on renewable resources enabling generation of electricity. Was made a comparison of the technical parameters of the selected solutions. For selected generating installations the value of electricity was calculated. Prepared results can help investor to decide to choose the right solution for himself.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2012, 4b; 28-31
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dwukierunkowy przekształtnik do magazynowania energii w systemie fotowoltaicznym
DC/DC converter for photovoltaic supercapacitor storage system
Autorzy:
Harasimczuk, M.
Powiązania:
https://bibliotekanauki.pl/articles/376669.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
przekształtnik dwukierunkowy
superkondensator
panel fotowoltaiczny
magazynowanie energii
Opis:
Magazynowanie energii pochodzącej z paneli fotowoltaicznych wymaga wykorzystania przekształtnika dwukierunkowego, charakteryzującego się odpowiednio wysokim współczynnikiem wzmocnienia napięciowego. Energia ta jest magazynowana w źródłach napięcia niskiego (akumulatory, superkondensatory). Zadaniem przekształtnika jest wzmocnienie napięcia magazynu energii w trakcie jego rozładowywania do napięcia wysokiego wynoszącego ok. 350–400 V, bądź obniżanie tego napięcia w trakcie jego rozładowywania. W artykule został zaprezentowany dwukierunkowy izolowany przekształtnik podwyższająco - obniżający napięcie. Przekształtnik składa się z mostka podwyższająco - obniżającego po stronie napięcia niskiego oraz zwykłego mostka po stronie napięcia wysokiego. Wysoki współczynnik wzmocnienia uzyskano dzięki wykorzystaniu przekładni transformatora. Wykorzystanie mostka podwyższająco – obniżającego zapewnia stabilną pracę przekształtnika przy zmiennym napięciu magazynu energii. Umożliwia to jego wykorzystanie do obsługi superkondensatorów, w których napięcie jest uzależnione od stopnia ich naładowania. W artykule omówiono zasadę sterowania przekształtnikiem, przedstawiono oraz omówiono wyniki badań symulacyjnych w środowisku PSpice. W badaniach zostały użyte modele tranzystorów z węglika krzemu.
Storage energy from the photovoltaic panels required bidirectional converter with high voltage gain. The converter step up voltage during discharge storage elements and step down during charge. In this paper bidirectional boost half bridge converter has been described. Proposed converter is operated in continues condition mode (CCM). Achieved high efficiency in constant output voltage with changing input voltage. This is necessary to use supercapacitors in storage systems because the voltage at its clamps depends on the state of charge of the supercapacitor. In article describes a bidirectional power flow control. Simulation results has been presented in PSpice. During discharge mode maximum efficiency is aproximally 96% during charging is aproximally 93% has been achieved. In simulation has been used SiC transistors models.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 87; 71-81
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quasi-rezonansowy przekształtnik podwyższający napięcie do zastosowań w fotowoltaice
Boost quasi-resonant converters for photovoltaic system
Autorzy:
Harasimczuk, M.
Powiązania:
https://bibliotekanauki.pl/articles/408410.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
panel fotowoltaiczny
przekształtnik quasi-rezonansowy
przełączanie przy zerowym prądzie
DC/DC converter
photovoltaic system
quasi-resonant (QR)
zero current switching (ZCS)
maximum power point tracking (MPPT)
Opis:
W artykule został zaprezentowany quasi-rezonansowy przekształtnik podwyższający napięcie przeznaczony do obsługi paneli fotowoltaicznych. Przekształtnik jest zasilany prądowo, co umożliwia realizację algorytmu MPPT. Wykorzystanie obwodu rezonansowego pozwala na przełączanie tranzystorów przekształtnika przy zerowym prądzie. Została opisana praca przekształtnika w układzie z tranzystorami przełączanymi ze stałą i ze zmienną częstotliwością. W artykule zaprezentowano wyniki badań symulacyjnych przeprowadzone za pomocą programu PSpice oraz porównano sprawność układów przy różnych mocach wyjściowych. W przekształtniku z tranzystorami przełączanym ze stałą częstotliwością wykorzystanie dodatkowego tranzystora załączającego pojemność rezonansową umożliwiło uzyskanie lepszej sprawności dla niewielkich mocy wejściowych niż w przekształtniku z tranzystorem przełączanym ze zmienną częstotliwością.
This paper presents PWM quasi-resonant boost converter for photovoltaic systems. The use of a resonant circuit enabled switching transistor in zero current (ZCS). Continuous conduction mode (CCM) with current control has been achieved. This allows to implement MPPT algorithm. The use of transistor switching resonant capacity allowed source (PV) current ripple with constant frequency and high efficiency in different load current. In the article has been discussed principle of operation the converter. Simulation converter in PSpice have been presented.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 4; 53-56
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of the MATLAB & SIMULINK environment to simulate the operation of a PV panel with an actual input function
Autorzy:
Jarmuda, T.
Mikulski, S.
Nawrowski, R.
Tomczewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/97441.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
photovoltaic cell
modelling
PV panels
MATLAB
environment
Opis:
The paper presents a method of modelling photovoltaic (PV) cells in the MATLAB & SIMULINK environment. A two-diode photovoltaic cell structure was developed, featuring series resistance. Measurements of a PV panel were carried out to determine the value of series resistance, open circuit voltage, and short-circuit current. The model suggested was used to operate the ST-STP020S-12/Cb panel with an actual input function (measurements of solar radiation power density of the south-east area of Poland in 2011). Simulation experiments were conducted of the system modelled to determine current changes, power changes, electric energy production, voltage-current characteristics, and to come up with results and draw final conclusions.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 497-510
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instalacje fotowoltaiczne. Podstawy fizyczne działania. Ochrona odgromowa. Zasady neutralizacji zagrożeń porażenia prądem elektrycznym w czasie pożaru
Photovoltaic Installations. Basis for Physical Operating. Lighting Protection and Neutralization Rules in Case of Fire
Autorzy:
Jaskółowski, W.
Wiatr, J.
Powiązania:
https://bibliotekanauki.pl/articles/136350.pdf
Data publikacji:
2016
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
panel fotowoltaiczny
instalacja fotowoltaiczna
porażenie prądem
photovoltaic panel
photovoltaic installation
electric shock
Opis:
Wyczerpujące się złoża węgla, stanowiącego podstawowy surowiec kopalny w energetyce, zmuszają do poszukiwania nowych źródeł energii. Od kilku lat odnotowuje się duże zainteresowanie energetyką odnawialną, do której należy zaliczyć również energię słoneczną. W naszym kraju coraz bardziej powszechna jest instalacja paneli fotowoltaicznych, tworzących przydomowe elektrownie słoneczne. Występujące na konstrukcji dachu budynku panele fotowoltaiczne, bardzo pożyteczne w warunkach normalnej eksploatacji, stwarzają duże zagrożenie porażenia prądem elektrycznym ratowników podczas działań ratowniczo-gaśniczych w przypadku powstania pożaru. W celu ochrony ratowników, koniecznym jest zabezpieczenie instalacji fotowoltaicznej przed możliwością porażenia prądem elektrycznym. Ponieważ w panelach fotowoltaicznych generacja energii elektrycznej w dzień odbywa się bez względu na stopień nasłonecznienia, na zaciskach wyjściowych generatora PV pojawia się napięcie o wartości znacznie przekraczającej wartości dopuszczalne długotrwale. W panelach fotowoltaicznych, w odróżnieniu od innych źródeł energii elektrycznej, nie ma możliwości przerwania produkcji energii elektrycznej w dzień. Sytuacja ta spowodowała konieczność poszukania innych rozwiązań, które pomimo ciągłej produkcji energii elektrycznej, umożliwiają obniżenie napięcia do wartości bliskiej zero na zaciskach całej elektrowni lub w poszczególnych panelach stanowiących elementy konstrukcyjne jej generatora. W artykule przedstawiono sposób pożarowego wyłączenia generatora przydomowej elektrowni fotowoltaicznej. W tym przypadku wykorzystana została charakterystyka prądowo- napięciowa panelu fotowoltaicznego, z której wynika, że zwarcie na zaciskach poszczególnych paneli lub na zaciskach poszczególnych gałęzi tworzących generator PV powoduje sprowadzenie napięcia do wartości bliskiej zero przy baku zagrożenia przez prądy zwarciowe płynące w obwodzie zwartych gałęzi generatora PV lub każdego z jego paneli. Wymuszone zwarcie powoduje neutralizację zagrożeń porażenia prądem ratowników uczestniczących w akcji ratowniczo -gaśniczej budynku, na którym zainstalowano panele PV.
The natural resources of the coal are depleting. As it used to be the most important energy source, the society was forced to search for new energy sources. For many years, growing interest in renewable energy sources has been observed, including solar energy. In our country, the photovoltaic systems are becoming popular ‘household’ power plants. The panels placed on the roof are useful during the normal operation conditions, but in case of a fire operation, they become dangerous for the firemen. In purpose to protect the rescuers, it is necessary to use electric shock prevention measures. As photovoltaic panels produce the energy during the whole day, under any exposure to sunlight, at the connectors of the panel, the voltage is expected, which value exceeds the acceptable thresholds. It is not possible to stop the generation of the energy during daytime. This situation has forced the explorations of the solutions, that might lower the voltage to close to zero values. The article presents the solution to be used as safety switch in case of fire. The current- voltage characteristics of the photovoltaic panel has been used. The short circuit caused within the installation will reduce the voltage on the connectors, without increasing the danger level itself. Forced short -circuit will effectively neutralize electric shock risk of the firemen.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2016, 3, 59; 71-99
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The design of a model for a 1 MW parabolic trough concentrated solar power plant in Sudan using TRNSYS software
Projekt modelu skoncentrowanej elektrowni słonecznej z rynną paraboliczną o mocy 1 MW w Sudanie z wykorzystaniem oprogramowania TRNSYS
Autorzy:
Jebreel, Abdelkareem Abdallah Abdelkareem
Hamad, Hamad Mohamed Ali
Powiązania:
https://bibliotekanauki.pl/articles/2127504.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
thermal storage
thermal solar collectors
photovoltaic solar panel
renewable source of energy
solar power plants
magazynowanie ciepła
termiczne kolektory słoneczne
fotowoltaiczne panele słoneczne
odnawialne źródła energii
elektrownie słoneczne
Opis:
Solar photovoltaic (PV) and concentrated solar power (CSP) systems are the present worldwide trends in utilizing solar energy for electricity generation. Solar energy produced from photovoltaic cells (PV) is considered the main common technology used due to its low capital cost; however, the relatively low efficiency of PV cells has spotlighted development and research on thermal engine applications using concentrated solar power. The efficiency of concentrated solar power is greater than that of PV and considering the solar potential for Sudan. Therefore, this study has been performed in an attempt to draw attention to the utilization of CSP in Sudan since the share of CSP is insignificant in comparison with PV, besides the suitability of CSP applications to Sudan’s hot climate and the high solar energy resource, the study presents a design model of 1 MW parabolic trough collectors (PTC) using the Rankine cycle with thermal energy storage (TES) in Sudan, by adopting reference values of the Gurgaon PTC power plant in India. The design of a 1 MW Concentrated Solar thermal power plant using parabolic trough collectors (PTC) and thermal energy storage is proposed. The simulation was performed for a site receiving an annual direct normal irradiance (DNI) of 1915 kWh/m2, near Khartoum. The results showed that the plant can produce between nearly 0.6 to 1 MWh during the year, and around 0.9 MWh when it encompasses thermal energy storage with an average thermal efficiency of 24%. These results of the PTC Power plant encourage further investigation and the development of CSP technologies for electricity generation in Sudan.
Systemy fotowoltaiczne (PV) i skoncentrowanej energii słonecznej (CSP) to obecne światowe trendy w wykorzystywaniu energii słonecznej do wytwarzania energii elektrycznej. Energia słoneczna wytwarzana z ogniw fotowoltaicznych (PV) jest uważana za główną powszechnie stosowaną technologię ze względu na jej niski koszt kapitałowy, jednak stosunkowo niska wydajność ogniw fotowoltaicznych zwróciła uwagę na rozwój i badania nad zastosowaniami silników cieplnych wykorzystujących skoncentrowaną energię słoneczną. W warunkach posiadanego potencjału słonecznego Sudanu wydajność skoncentrowanej energii słonecznej jest większa niż PV. Dlatego niniejsze badanie zostało przeprowadzone w celu zwrócenia uwagi na wykorzystanie CSP w Sudanie, ponieważ udział CSP jest nieznaczny w porównaniu z PV, pomimo przydatności zastosowań CSP do gorącego klimatu Sudanu i wysokich zasobów energii słonecznej. W pracy przedstawiono projekt modelu parabolicznych kolektorów rynnowych (PTC) o mocy 1 MW z wykorzystaniem cyklu Rankine’a z magazynowaniem energii cieplnej (TES) w Sudanie, przyjmując wartości referencyjne elektrowni Gurgaon PTC w Indiach. Zaproponowano projekt elektrowni słonecznej o mocy 1 MW wykorzystującej paraboliczne kolektory rynnowe (PTC) i magazynowanie energii cieplnej. Symulacja została przeprowadzona dla miejsca zlokalizowanego koło Chartumu, o rocznym bezpośrednim napromieniowaniu normalnym (DNI) 1915 kWh/m2. Wyniki pokazały, że elektrownia może wyprodukować od prawie 0,6 do 1 MWh w ciągu roku i około 0,9 MWh, przy wykorzystaniu magazynowanie energii cieplnej ze średnią sprawnością cieplną 24%. Te wyniki elektrowni PTC zachęcają do dalszych badań i rozwoju technologii CSP do wytwarzania energii elektrycznej w Sudanie.
Źródło:
Polityka Energetyczna; 2022, 25, 3; 67--90
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The performance analysis of dusty photovoltaic panel
Autorzy:
Katoch, Minakshi
Dahiya, Vineet
Yadav, Surendra Kumar
Powiązania:
https://bibliotekanauki.pl/articles/27312227.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
dust accumulation
tilt angle
photovoltaics
solar panel
transmittance
Opis:
Solar photovoltaic power is widely utilized in the energy industry. The performance of solar panels is influenced by different variables, including solar radiation, temperature, wind speed, relative humidity and the presence of haze or dirt. Outdoor solar panels are particularly susceptible to a decrease in energy efficiency due to the accumulation of dust particles in the air, which occurs as a result of natural weather conditions. The extent of dust deposition is primarily determined by factors such as the tilt angle of the panel, wind direction, cleaning frequency as well as local meteorological and geographical conditions. The dust on the solar cell glazing reduces the optical transmittance of the light beam, causing shadowing and diminishing the energy conversion productivity of the panels. Sand storms, pollution levels and snow accumulations all significantly impact the photovoltaic panel performance. These circumstances reduce the efficiency of solar panels. The experiment was carried out on two identical dust-accumulated and dust-free panels. The evaluation was carried out in two different situations on the offgrid stand-alone system: in a simulated atmosphere and in an open space during the day. The current-voltage curves have been developed for both panels at various tilt degrees. The features provide sufficient information to analyse the performance of the panels under consideration. The measurements demonstrate that as dust collects on the panel’s surface, the average output power and short circuit current decrease dramatically. The installation tilt angle affected the ratio of efficiency and average power outputs of dusty and clean panels.
Źródło:
Archives of Thermodynamics; 2023, 44, 2; 49--68
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Photovoltaic Panel Simulation Using a Mobile Application
Autorzy:
Kiriş, B.
Bingöl, O.
Uçar, M.
Powiązania:
https://bibliotekanauki.pl/articles/1031878.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
88.40.-j
88.40.H
Opis:
Today, the use of renewable energy resources is increasing rapidly because the solar energy is easily accessible and abundant. Solar energy is converted into electrical energy using photovoltaic panels. Photovoltaic panel is an energy source, which contains many solar cells, absorbing the solar energy. Factors affecting the operation of photovoltaic panels are the solar irradiance, the temperature, the surface, and the direction angle. For this reason, before employing a photovoltaic panel, the power values, which can be obtained from such photovoltaic panel should be analyzed and evaluated according to the application conditions, considering all these factors. In this study, calculation of power, current and voltage, generated by a photovoltaic panel, was performed on a mobile device for a determined region. Hourly, daily and monthly total power information, obtained according to the characteristics of the photovoltaic panel, such as panel position, direction and inclination, that can be obtained using the mobile device, are presented to the user by the developed application.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 922-925
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmniejszenie zapotrzebowania na energię poprzez wzrost efektywności energetycznej budynku i działania prosumenckie
Autorzy:
Kopietz-Unger, J.
Powiązania:
https://bibliotekanauki.pl/articles/161001.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
gospodarstwo domowe
zapotrzebowanie energii
efektywność energetyczna
źródło odnawialne
kolektor słoneczny
panel fotowoltaiczny
termomodernizacja
standard energetyczny
izolacja cieplna
household
energy demand
energy efficiency
renewable energy source
solar collector
photovoltaic panel
thermal retrofit
energy performance standard
thermal insulation
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 12, 12; 44-52
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vacuum circuit breaker switching in medium voltage networks with photovoltaic panels at low voltage side working as a supply source
Operacje łączeniowe wyłącznikiem próżniowym w sieciach średniego napięcia z uwzględnieniem paneli fotowoltaicznych pracujących po stronie niskiego napięcia jako źródło zasilania
Autorzy:
Kuczek, T.
Florkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/268833.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
panel fotowoltaiczny
wyłącznik próżniowy
przepięcia
PV cell
vacuum circuit breaker
overvoltage
Opis:
Breaking of inductive currents with use of vacuum circuit breaker is related to a problem of current chopping before its natural zero crossing. Due to the energy trapped in oscillatory circuit consisting of transformer's inductance and capacitance, the voltage across circuit breaker contacts starts to oscillate. Breaking of dielectric withstand can lead to multiple arc re-ignitions, which can result in generation of waveforms with high steepness and overvoltage peak values. In the present article, the principle of those phenomena was explained. Simulation results of circuit breakers opening operation in medium voltage network consisting of transformer with photovoltaic panels connected at low voltage side was also presented.
Wyłączniki próżniowe stosowane w elektroenergetyce średnich napięć charakteryzują się efektem tzw. ucięcia prądu przed jego naturalnym przejściem przez zero. Z powodu energii zmagazynowanej w indukcyjności oraz pojemności transformatora, podczas operacji otwierania napięcie powrotne pomiędzy zaciskami wyłącznika zaczyna oscylować. W momencie przekroczenia wytrzymałości dielektrycznej pomiędzy zaciskami, następuje ponowny zapłon łuku elektrycznego. Zjawisko to może doprowadzić to powstania przepięć o wysokiej stromości oraz wartościach szczytowych. W pracy zaprezentowano wyniki symulacji procesu otwierania wyłącznika próżniowego w sieci z transformatorem zasilanym ze strony niskiego napięcia poprzez panele fotowoltaiczne.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2012, 31; 85-88
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies