Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "petrochemical wastewater" wg kryterium: Wszystkie pola


Wyświetlanie 1-4 z 4
Tytuł:
Carbonaceous materials in petrochemical wastewater before and after treatment in an aerated submerged fixed-bed biofilm reactor
Autorzy:
Trojanowicz, K.
Wojcik, W.
Powiązania:
https://bibliotekanauki.pl/articles/185052.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Chemical Oxygen Demand fractions
petrochemical wastewater
biofilm reactor
zapotrzebowanie tlenu
petrochemiczne ścieki
reaktor
Opis:
Results of the studies for determining fractions of organic contaminants in a pretreated petrochemical wastewater flowing into a pilot Aerated Submerged Fixed-Bed Biofilm Reactor (ASFBBR) are presented and discussed. The method of chemical oxygen demand (COD) fractionation consisted of physical tests and biological assays. It was found that the main part of the total COD in the petrochemical, pretreated wastewater was soluble organic substance with average value of 57.6%. The fractions of particulate and colloidal organic matter were found to be 31.8% and 10.6%, respectively. About 40% of COD in the influent was determined as readily biodegradable COD. The inert fraction of the soluble organic matter in the petrochemical wastewater constituted about 60% of the influent colloidal and soluble COD. Determination of degree of hydrolysis (DH) of the colloidal fraction of COD was also included in the paper. The estimated value of DH was about 62%. Values of the assayed COD fractions were compared with the same parameters obtained for municipal wastewater by other authors.
Źródło:
Chemical and Process Engineering; 2016, 37, 3; 373-382
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nad zastosowaniem nadtlenku wodoru do unieszkodliwiania siarczkowych ługów zużytych w przemyśle rafineryjnym
Hydrogen peroxide oxidation of refinery alkali spent wastewater
Autorzy:
Kardasz, K.
Kędzierska, E.
Konopka, M.
Wilkanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/257314.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
nadtlenek wodoru
ług zużyty
ścieki przemysłowe
przemysł naftowy
hydrogen peroxide
alkali spent
spent caustic
industrial wastewater
petrochemical industry
Opis:
Przeprowadzono badania laboratoryjne nad wykorzystaniem nadtlenku wodoru do oczyszczania próbek przemysłowych uciążliwego odpadu rafineryjnego - ługów zużytych, poddanych wstępnej obróbce przemysłowej, zwanych roboczo mieszaniną poreakcyjną. Za kluczowe zanieczyszczenia uznano związki siarki i fenole. Prowadzono utlenianie w różnych warunkach, by doprowadzić do usunięcia tych dwu grup związków w stopniu umożliwiającym włączenie odpadu do systemu ściekowego. Określono optymalne warunki reakcji, uznano jednak, że korzystne jest pozostawienie mieszaniny po zakończeniu reakcji na kilka godzin w celu pełnego przereagowania zanieczyszczeń z nadtlenkiem wodoru. Po tym czasie uzyskiwano produkt jasny, klarowny i pozbawiony charakterystycznego odoru.
Refinery alkali spent (spent caustic) means the harmful wastewater formed after alkali washing of refinery hydrocarbon streams and containing odorous sulfides, phenolates, carbonates and other salts resulted in the reaction of sodium cation with acidic compounds present in crude oil. The aim of the research was to reduce contaminants to the level that allows leading the wastewater directly to the industrial sewage system with the hydrogen peroxide wet oxidation method. The oxidation was carried out for the so called postreaction mixture obtained after preliminary plant treatment. There were two kinds of the postreaction mixture, one - after being acidified with sulfuric acid (pH 3.5-4); the other one - the postreaction mixture after alkalisation (pH 8.5- -9). Both of the postreaction mixtures were subsequently treated with hydrogen peroxide so as to remove the essential contaminants: odorous sulfur compounds and harmful phenols in the range permitted in the industrial sewerage system. The optimal reaction conditions were established. It was assumed that the result was even better when the reaction mixture was left for a few hours longer to let all the contaminants react completely with hydrogen peroxide. After that time, the postreaction mixture was always light, clear and odourless.
Źródło:
Problemy Eksploatacji; 2008, 2; 73-81
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermally activated persulfate treatment and mineralization of a recalcitrant high TDS petrochemical wastewater
Autorzy:
Jorfi, S.
Pourfadakari, S.
Ahmadi, M.
Akbari, H.
Powiązania:
https://bibliotekanauki.pl/articles/779544.pdf
Data publikacji:
2017
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
Industrial wastewater treatment
Thermally activation
persulfate Petrochemical industry
High TDS wastewater
Opis:
Thermally activated persulfate efficiency for the treatment of a recalcitrant high TDS wastewater was investigated. The specific character of studied wastewater was high TDS content of around 23820 mg/L and BOD5/COD ratio of 0.07. Effective operational parameters including initial pH values of 3–9, reaction temperature of 40–80°C and persulfate concentrations of 0.5–5 g/L for COD removal were investigated in batch mode experiments. Removal efficiency was pH and temperature dependent. The COD and TOC removal of 94.3% and 82.8% were obtained at persulfate concentration of 4 g/L, initial pH value of 5 and temperature of 70°C after 180 min for initial COD concentration of 1410 mg/L. The pseudo first-order kinetic model was best fitted with COD removal (R2  = 0.94).
Źródło:
Polish Journal of Chemical Technology; 2017, 19, 2; 72-77
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorption of the petrochemical pollutants released at the small vehicle-service facilities on the coal refinery sludge/pyrocarbon compositions
Adsorpcja zanieczyszczeń petrochemicznych uwalnianych w małych obiektach serwisowych pojazdów na kompozycje osadu węglowego/pirowęglowego
Autorzy:
Fedoryak, Mariya
Boruk, Olena
Boruk, Sergiy
Winkler, Igor
Powiązania:
https://bibliotekanauki.pl/articles/1841508.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
coal refinery waste
pyrocarbon
adsorption efficiency
petrochemicals
pollution
wastewater treatment technologies
odpady z rafinerii węgla
karbonizat
efektywność adsorpcji
petrochemia
zanieczyszczenia
technologie oczyszczania ścieków
Opis:
It has been proven that the use of coal-like adsorbents with the mosaic and hydrophobic surface structure is efficient in cleaning the wastewater from a wide range of pollutants under the condition of their uncontrolled release from various small enterprises. is range includes such environmentally dangerous agents as petrochemicals and other pollutants formed at car filling, carwash stations or other similar facilities. Technical pyrocarbon and the coal refinery sludges are readily available waste materials with high porosity, which exhibit some adsorption activity and can be utilized in water/wastewater treatment solutions. en the adsorbents can be either disposed of at the landfill areas or incinerated as components of some secondary fuels. e highest adsorption performance is achieved for the sorbent mixture of the refinery sludges and technical pyrocarbon with the ratio of the components 4:1. If the wastewater is flowing through this composition, the degree of petrochemicals removal reaches 75-80% for the mixture sludge/ technical pyrocarbon, while the pure pyrocarbon ensures the removal degree of 15-20% only. ough adsorption efficiency under stationary conditions (keeping the adsorbent and the wastewater in contact inside some decontamination pond/vessel for at least 24 h) is higher, this option is hard-to-realize for a small car service/wash station. As an alternative, comparatively small wastewater cleaning cartridges filled with the 4:1 mixture of coal sludge and technical pyrocarbon can be recommended for preliminary decontamination of the wastewater formed at such enterprises before their discharge to the local municipal sewerage lines.
Wykazano, że zastosowanie adsorbentów węglopochodnych o mozaikowej, hydrofobowej strukturze powierzchni skutecznie oczyszcza ścieki z szerokiej gamy zanieczyszczeń. Adsorbowane są niebezpieczne dla środowiska substancje takie jak produkty petrochemiczne i inne zanieczyszczenia powstające na stacjach paliw, myjniach samochodowych lub innych podobnych obiektach. Techniczny karbonizat węglowy i szlamy z rafinerii węgla są łatwo dostępnymi materiałami odpadowymi o wysokiej porowatości, które wykazują pewną aktywność adsorpcyjną i mogą być wykorzystywane do oczyszczania wody/ścieków. Następnie adsorbenty mogą być albo składowane na składowiskach odpadów, albo spalane jako składniki niektórych paliw wtórnych. Najwyższą wydajność adsorpcji uzyskuje się dla mieszaniny sorbentów z osadów rafineryjnych i karbonizatu technicznego o stosunku składników 4:1. Jeżeli ścieki przepływają przez tę kompozycję, stopień usunięcia petrochemikaliów osiąga 75-80% dla mieszaniny osad/karbonizat techniczny, podczas gdy czysty karbonizat zapewnia stopień usunięcia tylko 15-20%. Chociaż wydajność adsorpcji w warunkach stacjonarnych (utrzymywanie adsorbentu i ścieków w kontakcie w naczyniu dekontaminacyjnym przez co najmniej 24 godziny) jest wyższa, ta opcja jest trudna do zrealizowania w przypadku małych stacji obsługi/myjni samochodowych. Jako alternatywę można polecić stosunkowo niewielkie wkłady do oczyszczania ścieków wypełnione mieszaniną mułu węglowego 4:1 i technicznego karbonizatu do wstępnego odkażania powstających w tego typu przedsiębiorstwach ścieków przed ich odprowadzeniem do lokalnych miejskich sieci kanalizacyjnych.
Źródło:
Inżynieria Mineralna; 2021, 1; 61-66
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies