Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "peak unit" wg kryterium: Wszystkie pola


Wyświetlanie 1-4 z 4
Tytuł:
Peak detection unit for Free-Space-Optics receiver
Autorzy:
Achtenberg, Krzysztof
Mikołajczyk, Janusz
Szabra, Dariusz
Prokopiuk, Artur
Bielecki, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/221334.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
peak detection
infrared receiver module for optical communications
open path laser communications
free space optics
quantum cascade laser
Opis:
The paper presents verification of a peak detection method cooperating with infrared radiation detector module applications. The work has been divided into parts including SPICE simulations and presentation of results obtained with the constructed prototype. The design of the peak detector dedicated to applications with very short pulses requires a different approach than that for standard solutions. It is mainly caused due to the ratio of pulse width and time period. In the described application this ratio is less than 10%. The paper shows testing of an analogue circuit which is capable to be inserted in these applications.
Źródło:
Metrology and Measurement Systems; 2019, 26, 2; 377-385
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operation of a power unit as a peak unit and its impact on the economy and reliability of the power system
Praca bloku energetycznego w charakterze jednostki szczytowej i jej wpływ na ekonomię i niezawodność systemu elektroenergetycznego
Autorzy:
Rusin, A.
Wojaczek, A.
Powiązania:
https://bibliotekanauki.pl/articles/181706.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Metalurgii Żelaza im. Stanisława Staszica
Tematy:
power unit
wind power plants
peak unit
reliability of power system
blok energetyczny
siłownia wiatrowa
jednostka szczytowa
niezawodność systemu
Opis:
Wind power plants are at the forefront of the development of renewable energy sources (RES) but their operation depends on changing weather conditions. Favouring energy obtained from renewable sources forces the operation of conventional energy as a regulator balancing the system’s demand. Coal-fired power units were designed for continuous operation and their efficiency decreases if they are used as peak units. The increased number of start-ups and frequent fluctuations in the generated power lead in the long run to the accumulation of consumption processes such as thermal fatigue and cracking. Another noticeable effect is also the decrease in reliability indicators and increased operating costs associated with expensive start-ups. The paper presents an estimation of operating costs related to more frequent start-ups of a power unit. The impact of the deterioration of reliability indicators on the production capacity of a single power plant as well as the reliability of the entire system was also analysed.
Siłownie wiatrowe stoją na czele rozwoju odnawialnych źródeł energii (OZE), lecz ich praca zależy od zmiennych warunków pogodowych. Faworyzowanie energii uzyskanej z odnawialnych źródeł wymusza pracę konwencjonalnej energetyki jako regulatora bilansującego zapotrzebowanie systemu. Bloki węglowe projektowane były do pracy ciągłej i ich sprawność spada, jeżeli użytkowane są jako jednostki szczytowe. Zwiększona liczba rozruchów i częste fluktuacje mocy generowanej prowadzą w dłuższej perspektywie do kumulacji procesów zużycia takich jak zmęczenie cieplne i pękanie. Innym zauważalnym efektem jest również spadek wskaźników niezawodności i zwiększone koszty eksploatacji związane z drogimi rozruchami. W artykule przedstawiono oszacowanie kosztów eksploatacji związanych z częstszymi rozruchami bloku energetycznego. Analizowano również wpływ pogorszenia się wskaźników niezawodności na możliwości produkcyjne pojedynczej elektrowni jak i na niezawodność całego systemu.
Źródło:
Prace Instytutu Metalurgii Żelaza; 2018, T. 70, nr 3, 3; 46-50
0137-9941
Pojawia się w:
Prace Instytutu Metalurgii Żelaza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The best synthetic unit hydrograph for peak discharge analysis. Case: the Bengawan Solo River, section Dengkeng–Pusur
Autorzy:
Sirait, Nova D.
Sobriyah, -
Hadiani, Rintis
Ikhsan, Cahyono
Powiązania:
https://bibliotekanauki.pl/articles/1844289.pdf
Data publikacji:
2021
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
Bengawan Solo River
maximum flood discharge
the SUH of SCS
the SUH of Nakayasu
the SUH of Gama I
Opis:
This paper aims to analyse the flood discharge based on the Synthetic Unit Hydrograph (SUH), using the Soil Conservation Service method (SCS), the SUH of Nakayasu method, and the SUH of Gama I method. Modelling formed the basis of the research conducted on the Bengawan Solo River, Indonesia. The embankment construction on the Dengkeng–Pusur Section was designed as a method of flood control in 1988. The problem was that around its location are densely populated cities, industrial areas, and agricultural areas. In order to measure the risk of embankment failure and water structure planning in general, it is necessary to analyse the maximum flood discharge. There are several methods for analysing maximum flood discharge, so finding a suitable method is essential due to the lack of measuring tools to calculate flood discharge in some areas. The calculation is compared with the observation data at the Serenan AWLR station, which is in the Dengkeng–Pusur section. The observation rainfall data was covered a 20 year period (1999–2018). According to the method used, the analysis is based on series data on four rainfall stations, the watershed characteristics, and other parameters. Furthermore, the maximum flood discharge from the calculation is compared with the observational data at the Serenan station. The result shows that the best SUH is Gama I method compared to the observation maximum flood discharge in AWLR Serenan Station, with an 8.0% error. The other method, the SUH Nakayasu method with a 16.6% error, and the SUH SCS method with a 39.5% error.
Źródło:
Journal of Water and Land Development; 2021, 50; 56-63
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evidence for the invalidity of the Wingate test for the assessment of peak power, power decrement and muscular fatigue
Autorzy:
Robergs, Robert A
Kennedy, David
Gibson, Ann L.
Zuhl, Micah
Hsu, Hung-Sheng
Beam, Jason
Salgado, Roy M.
White, Ailish C.
Majumdar, Aditi
Lawson, Steve
Estrada, Edson
Sierra, Gustavo
Powiązania:
https://bibliotekanauki.pl/articles/1054919.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
cadence
ergometry
fatigue
force
motor unit recruitment
Opis:
We hypothesized that the protocol-induced initial cadence of the WAnT is too high to allow high muscle force production and peak power generation. Twenty endurance, strength or power trained subjects (9 male, 11 female) completed two 30 s maximal exertion stationary cycle ergometer tests involving the traditional peak cadence start (TRAD) vs. a stationary start (STAT). Inertia corrected mechanical power, cadence, EMG from the vastus lateralis, and applied force to the pedals were measured continuously throughout both tests. Peak power was higher during TRAD; 11.32 ±1.41 vs. 10.40 ±1.35 Watts/kg (p < 0.0001), as was peak cadence; 171.4 ±16.3 vs. 120.9 ±15.1 rev/min (p < 0.0001). However, during TRAD EMG root mean squared (rms) increased continuously throughout the test, force applied to the pedals increased from 1 to 3 s (0.73 ±0.27 vs. 0.90 ±0.39 N/kg; p = 0.02) and thereafter remained relatively stable. EMG mean frequency also increased from 1 to 3 s, but then decreased throughout the remainder of the test. During TRAD, mechanical power decreased near immediately despite increasing EMG rms, EMGmean frequency and force application to the pedals. The initial 10 s of data from the WAnT is invalid. We recommend that intense cycle ergometer testing should commence with a stationary start.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2015, 10, 2; 63-78
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies