Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "passive cooling" wg kryterium: Wszystkie pola


Tytuł:
Passive cooling through the atmospheric window for vehicle temperature control
Autorzy:
Khan, Umara
Zevenhoven, Ron
Powiązania:
https://bibliotekanauki.pl/articles/1955001.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal radiation
passive cooling
vehicle skylight
greenhouse effect
computational fluid dynamics
Opis:
One of the most energy-intensive activities for a vehicle is space air conditioning, for either cooling or heating. Considerable energy savings can be achieved if this can be decoupled from the use of fuel or electricity. This study analyzes the opportunities and effectiveness of deploying the concept of passive cooling through the atmospheric window (i.e. the 8– 14 nm wavelength range where the atmosphere is transparent for thermal radiation) for vehicle temperature control. Recent work at our institute has resulted in a skylight (roof window) design for passive cooling of building space. This should be applicable to vehicles as well, using the same materials and design concept. An overall cooling effect is obtained if outgoing (long wavelength greater than 4 nm) thermal radiation is stronger than the incoming (short wavelength less than 4 nm) thermal radiation. Of particular interest is to quantify the passive cooling of a vehicle parked under direct/indirect sunlight equipped with a small skylight, designed based on earlier designs for buildings. The work involved simulations using commercial computational fluid dynamics software implementing (where possible) wavelengthdependency of thermal radiation properties of materials involved. The findings show that by the use of passive cooling, a temperature difference of up to 7–8 K is obtained with an internal gas flow rate of 0.7 cm/s inside the skylight. A passive cooling effect of almost 27 W/m2 is attainable for summer season in Finland. Comparison of results from Ansys Fluent and COMSOL models shows differences up to about 10 W/m2 in the estimations.
Źródło:
Archives of Thermodynamics; 2021, 42, 3; 25--44
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance Enhancement of a Photovoltaic Module by Passive Cooling Using Water-Based Aluminum Oxide Nano-Fluid
Autorzy:
Hamdan, Mohammad A.
Powiązania:
https://bibliotekanauki.pl/articles/2086398.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PV cooling
nanotechnology
PV performance
fined PV
Opis:
The performance of a PV (photovoltaic) module relies heavily on the operating temperature. The aim of the current study was to improve PV performance by passive cooling with nano-coated aluminum fins attached to the backside of the photovoltaic panels. Four identical PV panels were installed side by side for simultaneous measurements. The first one (B) is a basic PV that was used for comparison purposes, the second one (N) PV, which is coated with water-based Al2O3 nano-fluid, the third is finned PV (F), with fins being attached to its backside and the Al2O3 nano-fluid coated fins are attached to the backside of the fourth PV (FN). The hourly electrical generated power by each PV, I-V, and I_V curves for each PV were recorded and stored using I-V Checker. In addition, the backside temperature of each PV and the ambient temperature were measured on an hourly basis using K-type thermocouples; the measured temperature values were stored in a data logger. It was found that the (FN) PV gave the best performance compared to the base unit, with an increase in the generated power by 5.77%, followed by the nanocoated (N) PV with an increase of 2.14% and finally the finned (F) PV with an increase of 0.74%. Furthermore, the PV with the nano-coated fins exhibits the lower temperature 31°C, followed by the nano-coated PV, and finally the fined PV, with the backside average temperature of the basic unit being 39°C.
Źródło:
Journal of Ecological Engineering; 2022, 23, 4; 276--283
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Komin słoneczny jako przykład pasywnego systemu chłodzenia budynku
Solar chimney as example of passive cooling system in building
Autorzy:
Nakielska, M.
Pawłowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/402621.pdf
Data publikacji:
2016
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
komin słoneczny
wentylacja naturalna
pasywny system chłodzenia
solar chimney
natural ventilation
passive cooling system
Opis:
Obecnie ogólnoświatowym trendem w kształtowaniu budynków jest poszukiwanie nowych rozwiązań, które umożliwiają komfortowe użytkowanie obiektów budowlanych w zgodzie ze środowiskiem naturalnym i zapewniając spadek zużycia energii. W artykule przedstawiono problematykę wentylacji obiektów budowlanych, które nie generują zwiększenia kosztów eksploatacyjnych obiektu. Na podstawie dostępnej literatury, zaprezentowano kilka przykładowych rozwiązań umożliwiających obniżenie temperatury w pomieszczeniach w sposób inny niż montaż instalacji klimatyzacyjnej. Przedstawiono opis stanowiska badawczego i wykonane badania potwierdzające zasadność stosowania komina słonecznego w celu intensyfikacji wymiany powietrza w pomieszczeniu z jednoczesnym przewietrzeniem nocnym pomieszczeń w okresie letnim.
Nowadays, searching new solutions is a worldwide trend in creating buildings. Those solutions enable a comfortable use of building structures in harmony with natural environment and ensure reducing energy consumption. The article presents the issues connected with the ventilation of building structures which do not generate a rise of the maintenance costs in building. Based on the available literature, some exemplary solutions that make it possible to reduce the temperature in rooms in a way other than by installing air conditioning systems were shown. The description of a research stand and conducted research, confirming the legitimacy of using a solar chimney in order to intensify the air exchange in a room in parallel with a night ventilation of the room in the summer time, were presented.
Źródło:
Budownictwo i Inżynieria Środowiska; 2016, 7, 3; 149-152
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assesment of Passive Cooling in Residential Application under Moderate Climate Conditions
Ocena możliwości stosowania pasywnego chłodzenia do celów domowych w klimacie umiarkowanym
Autorzy:
Petela, K.
Szlęk, A.
Powiązania:
https://bibliotekanauki.pl/articles/389072.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
passive cooling
nocturnal sky
solar collector
residential cooling
chłodzenie pasywne
nocny nieboskłon
kolektor słoneczny
chłodzenie radiacyjne
Opis:
In the face of environmental regulations, renewable energy systems are anticipated to become more attractive. Passive buildings may appear promising in terms of energy saving. The aim of the work is an investigation of energy effects of using radiative passive cooling. System analysed here bases on the radiative heat exchange with nocturnal sky. On every exposed surface, beyond the convection mechanism, a radiative heat exchange with the sky takes place. Analysis shows that passive cooling has a potential in cold production, however is sensitive to ambient conditions and that cold supply is inversely proportional to demands. Small value of average heat loss from the radiator makes the system independently unable to fulfil cooling demand, however may become an attractive, eco-friendly supplement to a conventional air-conditioner.
Wobec wymagań środowiskowych systemy wykorzystujące odnawialne źródła energii są coraz częściej stosowane i wdrażane również do rozwiązań budownictwa pasywnego. Celem pracy jest analiza efektów energetycznych wykorzystania pasywnego chłodzenia w budynku mieszkalnym. Podmiotem pracy jest system opierający swoje działanie na promienistej wymianie ciepła z nocnym nieboskłonem. Na powierzchni każdego ciała wyeksponowanej ku niebu, oprócz konwekcyjnej wymiany ciepła, odbywa się również radiacyjna wymiana ciepła z nieboskłonem. Analiza ukazuje potencjał chłodzenia pasywnego tego typu w produkcji chłodu, jednakże wskazuje na silną zależność systemu od warunków otoczenia oraz na fakt, że podaż chłodu jest odwrotnie proporcjonalna do zapotrzebowania. Niskie wartości strumieni strat ciepła z pasywnego radiatora sprawiają, że system nie może stanowić samodzielnego źródła produkcji chłodu, jednak może stać się atrakcyjnym, przyjaznym środowisku dodatkiem do konwencjonalnego układu klimatyzacyjnego.
Źródło:
Ecological Chemistry and Engineering. A; 2016, 23, 2; 211-225
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie pompy ciepła w instalacji z odnawialnymi źródłami energii do chłodzenia pasywnego
Heat pump usage in the installation with renewable energy sources for passive cooling
Autorzy:
Pater, A.
Magiera, J.
Głuszek, A.
Neupauer, K.
Powiązania:
https://bibliotekanauki.pl/articles/2072216.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
chłodzenie pasywne
pompa ciepła
gruntowy wymiennik ciepła
passive cooling
heat pump
vertical ground heat exchanger
Opis:
W pracy przedstawiono wyniki badań pracy pompy ciepła z pionowym gruntowym wymiennikiem ciepła w trybie chłodzenia pasywnego wybranych pomieszczeń budynku mieszkalno-usługowego w okresie letnim 2012 roku. Określono sezonową, oraz dla poszczególnych dni, dobową wartość współczynnika wydajności chłodniczej pompy ciepła. Omówiono wpływ temperatury solanki, czasu pracy pompy ciepła oraz ilości odebranego ciepła w chłodnicy na moc chłodniczą sondy pionowej.
Investigation results dealing with the heat pump operation with a vertical ground heat exchanger in passive cooling mode of selected rooms in a re- sidential-commercial building in 2012 summer season are presented in the paper. The seasonal, and for each day, daily value of heat pump cooling capacity coefficient was specified. Effect of brine temperature, heat pump operation time and amount of heat received in a cooler on vertical probe cooling power is discussed.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 5; 457--458
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natural ventilation and energy efficiency in non-domestic buildings
Autorzy:
Pieczara, J.
Powiązania:
https://bibliotekanauki.pl/articles/101474.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
natural ventilation
adaptive thermal comfort
energy efficiency
air quality
passive cooling
risk of overheating
thermal mass
Opis:
Over the past 50 years the use of air conditioning in non-domestic buildings has become a norm and an indicator of status. Today the rediscovering of the natural ventilation is a part of rediscovering the buildings’ energy efficiency, or maybe even a part of a wider approach, which is a desire to be closer to nature. The main task of all ventilation systems is to maintain an appropriate indoor air quality and to improve the indoor environment. Natural ventilation systems could do the above using less energy than mechanical systems. However, it requires also the implementation of other passive measures. The most important of them are: the reduction of the harmful air contaminants, the control of heat gains, the exposition of the building’s thermal mass and utilisation of the night cooling. Because of energy efficiency and thermal comfort reasons, in temperate climate ventilation systems have to work according to at least three scenarios: spring/autumn, winter and summer. The thermal comfort parameters in naturally ventilated buildings are usually more variable than in air-conditioned ones, what does not mean that the occupants will experience thermal discomfort. Therefore, thermal comfort in passively ventilated buildings should be evaluated according to the adaptive comfort standard, appropriated for the naturally ventilated buildings. The natural ventilation has its limits and probably not all buildings can be ventilated naturally. From the energy efficiency and thermal comfort reasons, implementing the mixed mode systems is sometimes more feasible. However, the real reason why the full potential of natural ventilation could not be explored is very often the lack of confidence in relying exclusively on it.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2017, III/1; 935-947
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praca gruntowego wymiennika ciepła na tle zmiennych warunków atmosferycznych
The efficiency of the ground-coupled heat exchanger under varying weather conditions
Autorzy:
Pązik, R.
Kostecki, J.
Powiązania:
https://bibliotekanauki.pl/articles/372004.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
gruntowy wymiennik ciepła
rekuperacja
wentylacja
chłodzenie pasywne
GŻWC
ground-coupled heat exchanger
recuperation
ventilaion
passive cooling
GHE
Opis:
W pracy omówiono zastosowanie gruntowego żwirowego wymiennika ciepła wykorzystywanego w systemach wentylacji z odzyskiem ciepła. Analizie poddano skuteczność pracy w zmiennych warunkach atmosferycznych, obejmujących zimę oraz lato. Zaprezentowano wyniki uzyskanych, dzięki wymiennikowi, temperatur i oceniono odczuwalny komfort po całorocznej eksploatacji.
In this article we present the work of the ground-coupled heat exchanger working in the systems with heat recovery. Efficiency of work under varying weather conditions, including winter and summer were analyzed. We also present the results of the temperature and comfort after a year-long operation.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2013, 152 (32); 113-123
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka aktywnych i pasywnych systemów chłodzenia za pomocą pompy ciepła
Characteristics of passive or active cooling systems by means of heat pump
Autorzy:
Piszczatowska, U.
Żukowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/403053.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
rewersyjna pompa ciepła
chłodzenie aktywne
chłodzenie pasywne
moduł klimatyzacyjny
geothermal heat pump
active cooling
passive cooling
air conditioning unit
Opis:
Geotermalne pompy ciepła są to urządzenia, które w okresie grzewczym wykorzystują ciepło gruntu jako tzw. źródło dolne do celów centralnego ogrzewania i ciepłej wody użytkowej. W artykule skupiono się jednak na temacie wykorzystania tego urządzenia do chłodzenia pomieszczeń w okresie letnim. Realizacja tego zamierzenia może odbywać się w trybie pasywnym bądź aktywnym. W pierwszym przypadku chłodzenie odbywa się przy bezpośrednim wykorzystaniu chłodu wody lub gruntu. Nie zużywa się przy tym energii na pracę sprężarki. Druga opisana w artykule możliwość to realizacja chłodzenia przy użyciu klimakonwektorów bądź ogrzewania płaszczyznowego. Scharakteryzowano również zintegrowany układ grzewczo-chłodniczy zainstalowany w budynku biurowym, w skład którego wchodzą wymienniki ciepła, pompa ciepła oraz moduł klimatyzacyjny HPAC.
Geothermal heat pumps are devices which use energy from the ground as an upper heat source for central heating and domestic hot water systems during the heating period. The first part of the paper focuses on applying these devices for the cooling of rooms in summertime. Implementation of this technology can be done in two cooling modes: passive or active. In the first case cooling is carried out by the direct use of cold water or soil. In this particular case there is no power consumption by compressor. The second possibility of implementation of cooling can be obtained by fan coil units or underfloor heating systems. The second part of the paper characterizes the integrated heating-cooling system, which is installed in the office building near Białystok. This system consists of heat exchangers, heat pump and air conditioning unit HPAC. System under consideration can operate both in the heating mode and as the passive and active cooling unit. This solution guarantees thermal comfort throughout all the year.
Źródło:
Budownictwo i Inżynieria Środowiska; 2010, 1, 3; 241-244
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania otworowego wymiennika ciepła w aspekcie ich parametrów cieplnych na potrzeby współpracy z pompą ciepła
Analysis parameters of heating – cooling installation with ground source heat pump in heating and passive cooling mode
Autorzy:
Pełka, G.
Luboń, W.
Kotyza, J.
Malik, D.
Powiązania:
https://bibliotekanauki.pl/articles/203804.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
gruntowe pompy ciepła
współczynnik przewodzenia ciepła
opór cieplny
otworowy wymiennik ciepła
geothermal heat pumps
coefficient of thermal conductivity
thermal resistance
hole heat exchanger
Opis:
Pompy ciepła pozyskujące energię z płytkich systemów geotermalnych są obecnie najbardziej efektywnymi urządzeniami grzewczo-chłodzącymi. Centrum Zrównoważonego Rozwoju i Poszanowania Energii WGGiOŚ AGH w Miękini prowadzi badania w zakresie pomp ciepła oraz otworowych wymienników ciepła. W celu kompleksowej realizacji badań opracowano przenośnie urządzenie do prowadzenia testów reakcji termicznej (TRT) dla otworowych wymienników ciepła. Koncepcja urządzenia zakładała wykorzystanie dostępnych, krajowych komponentów składowych, co miało zapewnić niski koszt budowy. Test reakcji termicznej gruntu pozwala na określenie efektywnego współczynnika przewodzenia ciepła, oporu cieplnego otworowego wymiennika ciepła oraz temperatury początkowej w wymienniku. Wykonane urządzenie testowano na wymiennikach testowych w Centrum w Miękini.
Geothermal heat pumps are the most efficient heating and cooling devices. The AGH Sustainable Development and Energy Saving Center in Miękinia conducts heat pump and borehole heat exchangers research. To do the complex research a portable thermal response test device was developed. The concept of this device assume the use of available, domestic parts with a low cost of the construction. Thermal response test allows to determine an effective ground heat transfer coefficient, borehole heat exchanger thermal resistance and undisturbed fluid temperature. The constructed device was tested on the borehole heat exchangers in the Miękinia Laboratory.
Źródło:
Technika Poszukiwań Geologicznych; 2018, R. 57, nr 2, 2; 93-106
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie odnawialnych źródeł energii i ciepła odpadowego w niskotemperaturowym systemie ogrzewczo-chłodzącym hali drukarni
Low temperature heating systems for production halls with use of renewable energy sources
Autorzy:
Bialik, W.
Gil, S.
Machulec, B.
Ochman, J.
Powiązania:
https://bibliotekanauki.pl/articles/105199.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
systemy ogrzewania
oszczędność energii
pompy ciepła
mata grzejna
pasywny system chłodzenia
heating systems
energy saving
heat pumps
heating mat
passive cooling system
Opis:
W pracy przedstawiono nowoczesny system ogrzewania hali drukarni oraz pomieszczeń biurowych i socjalnych. Został on zaprezentowany na dwóch schematach oraz omówiony w pierwszej części artykułu. Układ wykorzystuje pompy ciepła ciecz-ciecz oraz powietrze ciecz. Dla pomp ciecz-ciecz dolnym źródłem jest pionowy wymiennik gruntowy składający się z 13 otworów o głębokości 100 m. W opisywanym rozwiązaniu zastosowano także poziomy gruntowy wymiennik ciepła do ogrzewania czerpanego z otoczenia powietrza wentylacyjnego płynącego następnie do rekuperatorów pomieszczeń biurowych i socjalnych. Gruntowe wymienniki ciepła w trakcie ich budowy zostały zaprezentowane na jednym z rysunków. Pomieszczenia biurowe i socjalne ogrzewane lub schładzane są medium płynącym w matach umieszczonych w ścianach oraz w wybranych częściach podłogi. Dla ograniczenia strat ciepła związanych z wentylacją w instalacji zastosowano trzy układy rekuperacji (osobno dla pomieszczeń biurowych, socjalnych i hali drukarskiej). Poprawne działanie systemu zobrazowano w postaci wykresu zmian temperatur we wspomnianych pomieszczeniach. Dla największej centrali wentylacyjnej zamieszczono też przebieg temperatur strumieni powietrza dla wybranych dni. W podsumowaniu zawarto wnioski płynące z dotychczasowej eksploatacji oraz plany dalszego rozwoju systemu.
The paper presents a modern heating system of the printing hall, offices and social services. It was presented on two diagrams and discussed in the first part of the article. System utilizes the heat pumps of liquid-liquid and liquid air. For pumps of liquid-liquid the lower source is vertical ground heat exchanger, consisting of 13 holes having a depth of 100 m. In the described solution also been used horizontal ground heat exchanger to heat which has been taken from the environment of ventilation air flowing then to the recuperators of offices and social rooms. Ground heat exchangers during their construction are presented in one of the drawings. Office and social rooms are heated (or cooled) by medium flowing in the wall mats and in selected parts of a floor. To limit the heat loss associated with the ventilation in the system has been uses three sets of the recuperation (separately for offices, social rooms and printing hall). Correct system operation is illustrated in the graph of temperature changes in these rooms. The summary contains conclusions from current exploitation and plans for further development of the system.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 1; 461-468
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies