Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "optical microscopy" wg kryterium: Wszystkie pola


Wyświetlanie 1-36 z 36
Tytuł:
Near Field Optical Microscopy and Spectroscopy with STM and AFM Probes
Autorzy:
Bergossi, O.
Bachelot, R.
Wioland, H.
Wurtz, G.
Laddada, R.
Adam, P. M.
Bijeon, J. L.
Royer, P.
Powiązania:
https://bibliotekanauki.pl/articles/1968764.pdf
Data publikacji:
1998-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.60.Pb
42.62.Fi
61.16.Ch
68.35.Bs
Opis:
This article deals with a new generation of scanning near field optical microscopes (SNOM), called apertureless SNOM, based on metallic, semi-conductive or dielectric probes. The classification of the apertureless probe among the usual SNOM probes is discussed in the first part. Then, we present the different apertureless SNOM configurations that we develop, with various commercial AFM and home-made tungsten tips, and several illumination and collection modes. Finally, after a preliminary result in near field imaging, we propose a promising application of such microscopes dedicated to the near field fluorescence spectroscopy.
Źródło:
Acta Physica Polonica A; 1998, 93, 2; 393-398
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time-Resolved and Near-Field Scanning Optical Microscopy Study on Porphyrin J-Aggregate
Autorzy:
Miura, A.
Matsumura, K.
Su, X.
Tamai, N.
Powiązania:
https://bibliotekanauki.pl/articles/1993153.pdf
Data publikacji:
1998-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.47.+p
Opis:
Water-soluble porphyrin, 5,10,15,20-tetraphenyl- 21H,23H-porphine-tetrasulfonic acid (TPPS), forms J-aggregate in aqueous solution depending on experimental conditions such as pH, dye concentration, and/or ionic strength. The steady-state fluorescence and picosecond single-photon timing spectroscopy were applied for protonated monomer and J-aggregate in aqueous solution and in thin films to reveal the dynamics in the S$\text{}_{2}$ and S$\text{}_{1}$ states. The S$\text{}_{2}$ fluorescence spectra from the protonated monomer and J-aggregate were observed in addition to the normal S$\text{}_{1}$ fluorescence. The lifetime of the S$\text{}_{2}$ state was estimated to be ≈5 ps for J-aggregate, whereas the lifetime is shorter than 1 ps for protonated TPPS monomer. The mesoscopic structures of J-aggregate in thin film with and without polymer on the glass surface were examined by scanning near-field optical microscopy. With the surface topography and scanning near-field optical microscopy transmission images, TPPS J-aggregate was found to form a long and narrow tube-like structure which has a few μm length, 0.2-0.5 μm width, and 5-30 nm height. An unidirectional orientation of the structure was also found, which may be originated from the spin-coating process.
Źródło:
Acta Physica Polonica A; 1998, 94, 5-6; 835-846
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the quality of titanium oxide and copper oxide layers by means of optical microscopy
Autorzy:
Głuszek, A.
Sawicka-Chudy, P.
Wisz, G.
Sibiński, M.
Cholewa, M.
Powiązania:
https://bibliotekanauki.pl/articles/101772.pdf
Data publikacji:
2018
Wydawca:
Instytut Polityki Energetycznej im. Ignacego Łukasiewicza
Tematy:
titanium oxide
copper oxide
optical microscopy
histograms
Opis:
The aim of this paper is to analyse high-resolution optical images of the surface layers of titanium oxide and copper oxide. The materials were produced using the PREVAC Modular Platform for layer deposition located at the University of Rzeszów. Images with a magnification of 50x were obtained using an optical microscope. On the basis of the results obtained, the quality of the layers was evaluated based on the image analysis. The quantitative method of analysis was applied, as a result of which the conditions of the manufacturing process for which the obtained layers had the highest homogeneity were indicated. The minimum range of grey shade counting was from 65 to 150 and the maximum range from 135 to 220. The standard deviation was from 8 to 40%.
Źródło:
Energy Policy Studies; 2018, 1 (2); 39-51
2545-0859
Pojawia się w:
Energy Policy Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A simple model of the scanning near-field optical microscopy probe tip for electric field enhancement
Autorzy:
Wang, Y.
Cai, W.
Yang, M.
Liu, Z.
Shang, G.
Powiązania:
https://bibliotekanauki.pl/articles/174091.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
near-field tip
electromagnetic field enhancement
finite-difference time-domain
FDTD
Opis:
In this paper, we present a simple near-field probe model that is composed of an elongated ellipsoid and a finite metal truncated cone. The elongated ellipsoid has been shown to act as a protrusion or separate particle near a truncated cone apex with strong near-field enhancement under laser excitation. By controllably varying the length of the ellipsoid protrusion from the truncated cone, the truncated cone-ellipsoid probes can be adapted to the suitability of near-field probes. The effects of substrate material and excitation wavelength on the near field enhancement for different tip apexes are also discussed. In addition, we compared the properties of the truncated cone-ellipsoid probe with the widely used hemisphere conical tip by launching surface plasmon polaritons on plasmonic waveguides to prove the suitability of the truncated cone-ellipsoid probes as high performance near-field probes. The present simple model would provide a theoretical basis for the actual construction of probes.
Źródło:
Optica Applicata; 2017, 47, 1; 119-130
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistical Assessment of the Microstructure of Barite Aggregate from Different Deposits Using X-Ray Microtomography and Optical Microscopy
Autorzy:
Żołek, N.
Ranachowski, Z.
Ranachowski, P.
Jóźwiak-Niedźwiedzka, D.
Kudela, S. jr.
Dvorak, T.
Powiązania:
https://bibliotekanauki.pl/articles/351890.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
barite ore
barite aggregate
microstructure
optical microscopy
thin sections analysis
X-ray tomography
Opis:
Two different barite ore (barium sulfate BaSO4) specimens from different localizations were tested and described in this paper. Analysis of the microstructure was performed on polished sections, and on thin sections using X-ray microtomography (micro-CT), and optical microscopy (MO). Microtomography allowed obtaining three-dimensional images of the barite aggregate specimens. In the tomograms, the spatial distribution of the other polluting phases, empty space as well as cracks, pores, and voids – that exceeded ten micrometers of diameter-were possible to visualize. Also, the micro-CT allowed distinguishing between minerals of different density, like SiO2 and BaSO4. Images obtained and analyzed on thin sections with various methods using the optical microscopy in transmitted light delivered additional information on the aggregate microstructure, i.e. allow for estimation of the different kinds of inclusions (like the different density of the minerals) in the investigated specimens. Above methods, which were used in the tests, completed each another in order to supply a set of information on inclusions’ distribution and to present the important differences of the barite aggregate specimens microstructure.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2A; 697-702
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania mikroskopowe ureilitu NWA XXX
Microscopic Investigations of NWA XXX Ureilite
Autorzy:
Szurgot, Marian
Powiązania:
https://bibliotekanauki.pl/articles/1032789.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Meteorytowe
Tematy:
extraterrestrial matter
meteorite
meteorites
optical microscopy
ureilite
Opis:
New NWA XXX ureilite found in 2006 was investigated by optical microscopy in reflection and in transmission. Olivines, pigeonite, metal veins and dots, and carbon phases have been revealed and their features and distribution studied. Twinning of pigeonite, reduction rims, and poikilitic inclusions of olivine in large pigeonite crystals have been identified and characterized. NWA XXX meteorite belongs to olivine-pigeonite ureilites.
Źródło:
Acta Societatis Metheoriticae Polonorum; 2011, 2; 138-146
2080-5497
Pojawia się w:
Acta Societatis Metheoriticae Polonorum
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of factors determinant of siliceous electrical porcelain resistance to structural degradation
Autorzy:
Ranachowski, P.
Ranachowski, Z.
Kudela Jr., S.
Pawełek, A.
Piątkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/351813.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
porcelain insulating materials
ageing processes
acoustic emission (AE)
optical microscopy
Opis:
The subject of this study was investigation of the factors that have a decisive influence on the resistance of siliceous porcelain to degradation processes. There was tested material C 110 type, which is widely used for the production of low-voltage (LV) elements such as insulators and bushings. On the basis of mechanical-acoustic and microscopic research of small-sized samples, which were subjected to compression, there were distinguished successive stages of degradation of the material structure. In the authors* opinion, they have a reference to the ageing process, taking place during many years of work under operating conditions. Thus, it was possible to assess the structural factors that determine the durability and reliability of LV electroinsulating elements. The results were related to electrical aluminous porcelains.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 3; 1489-1496
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Moving-aperture-based three-dimensional micro-measurement system
Autorzy:
Fan, S.
Yu, M.
Jiang, G.
Wang, Y.
Wang, W.
Li, W.
Powiązania:
https://bibliotekanauki.pl/articles/174026.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical microscopy
computational photography
three-dimensional micro-measurement
moving aperture
Opis:
To overcome the depth-of-field limitation of an optical microscope image, a three-dimensional measurement method with a superior depth-of-field is proposed. In the proposed method, light-field information of different angles is obtained by moving the aperture and the three-dimensional scene is reconstructed by using a computational reconstruction technology. First, stereo matching of different aperture position images is performed to obtain the multi-aperture imaging deviation. The focal plane moving distance is thereby estimated. Then, the relational expression between the image coordinates and the focal plane moving distance is determined according to the image coordinates. Two dimensional coordinates of the space point are obtained by the expression coefficients. Finally, the depth coordinates are computed, and three-dimensional reconstruction of the spatial points is completed. Experiments of three-dimensional measurements of the calibration board with different angles and circuit boards are conducted. The results show that the maximum error of the distance measurement is controlled into 0.84%, and the maximum angle measurement error is controlled into 4.56%.
Źródło:
Optica Applicata; 2018, 48, 4; 533-547
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of Modified Aluminous Porcelain Subjected to Mechanoacoustic Tests
Autorzy:
Ranachowski, P.
Ranachowski, Z.
Wieczorek, K.
Jaroszewski, M.
Kudela, S. jr.
Powiązania:
https://bibliotekanauki.pl/articles/355059.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical porcelain materials
ageing processes
acoustic emission
AE
optical microscopy
Opis:
The paper presents the microscopic and mechanoacoustic study of degradation processes of the porcelain material C 130 type. This kind of material is used in the production of the most durable and reliable electrotechnical elements. Raw material composition of the studied porcelain was modified. This had an impact on the inner properties, cohesion and – in consequence – on operational properties of the material. Using mechanical-acoustic and microscopic methods of testing of small-size samples that were subjected to compression, it was possible to distinguish successive stages of degradation of the porcelain structure. These stages were generally typical of the porcelain materials. In the authors’ opinion, they are connected to the ageing process happening over many years of work under operating conditions. Optimization of composition and technological properties – important during technological processes – resulted in a slight decrease in inner cohesion of the porcelain. When compared to the reference material – typical domestic C 130 material, mechanical strength was somewhat lower. Carried out investigations proved that resistance of the investigated material to the ageing degradation process – during long term operation – also decreased. The improvement of technological parameters and the reduction in the number of defective elements occurred simultaneously with some decrease in the operational parameters of the material. To restore their initial high level, further work is needed to optimize the raw material composition of the porcelain.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 4; 1821-1826
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Petrologiczna i mineralogiczna charakterystyka chondrytu węglistego NWA 4967
Petrological and mineralogical characteristics of NWA 4967 carbonaceous chondrite
Autorzy:
Szurgot, Marian
Powiązania:
https://bibliotekanauki.pl/articles/1033012.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Meteorytowe
Tematy:
NWA 4967
chondrites
extraterrestrial minerals
meteorites
optical microscopy
petrographic thin sections
Opis:
NWA 4967 carbonaceous chondrite thin section was investigated by optical microscopes in transmission and in reflection. Minerals of the meteorite have been identified and microstructure analyzed. Chondrules, matrix, metal phases, AOAs and CAIs are constituents of the rock, as expected. Olivine, clinopyroxene, orthopyroxene, troilite, kamacite and feldspar have been detected. Various types of chondrules including: PO, POP, PP, RP, BO, C, GOP and GO chondrules were identified. Compositional zoning of some olivines, diagnostic cracks in pyroxenes, clinopyroxene twins, and chondrule rims have been observed and analyzed. Our previous EPMA and Raman data as well as present optical data confirm that NWA 4967 belongs to CO3.2 chondrites, as previously classified.
Źródło:
Acta Societatis Metheoriticae Polonorum; 2014, 5; 121-148
2080-5497
Pojawia się w:
Acta Societatis Metheoriticae Polonorum
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental analysis by measurement of surface roughness variations in turning process of duplex stainless steel
Autorzy:
Krolczyk, G. M.
Legutko, S.
Powiązania:
https://bibliotekanauki.pl/articles/220659.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
turning
coatings
friction-reducing
optical microscopy
surface roughness analysis and models
Opis:
The objective of the investigation was to identify surface roughness after turning with wedges of coated sintered carbide. The investigation included predicting the average surface roughness in the dry machining of Duplex Stainless Steel (DSS) and the determination of load curves together with roughness profiles for various cutting conditions. The load curves and roughness profiles for various cutting wedges and variable cutting parameters were compared. It has been shown that dry cutting leads to a decrease in friction for lubricated surfaces, providing a small initial contact area where the surface is contacted. The study has been performed within a production facility during the production of electric motor parts and deep-well pumps.
Źródło:
Metrology and Measurement Systems; 2014, 21, 4; 759-770
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary Structures Assessment of Some TRIP Steels
Autorzy:
Pantilimon, Mircea Cristian
Berbecaru, Andrei-Constantin
Coman, George
Sohaciu, Mirela G.
Dumitrescu, Ruxandra Elena
Ciucă, Sorin
Gherghescu, Ioana-Arina
Predescu, Cristian
Powiązania:
https://bibliotekanauki.pl/articles/27313868.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
TRIP steel
optical microscopy
Vickers hardness
retained austenite
car body material
Opis:
Automotive industry is constantly interested in building cars made of light and high strength parts in order to reduce the emission levels, the fuel consumption and minimize the effects of a car crash. Some parts may be made of lighter materials, but the steel ones must compensate the strength needed for the car body. Research is made for finding new materials showing high strength combined with high ductility. Among them, transformation - induced - plasticity steels are of great interest, efforts being made to improve their characteristics. A new composition of such a steel is presented, its features being compared with those of three other steels of the same class and category. Optical microscopy at different magnifications is performed, together with Vickers hardness test. Structural particularities are found for each tested steel, justified by their own chemical compositions. The new steel reveals important characteristics: besides the mainly bainitic structure, it has both larger ferritic areas and amounts of retained austenite, making him proper for further study.
Źródło:
Archives of Metallurgy and Materials; 2023, 68, 2; 491--498
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka utworów czerwonego spągowca w aspekcie badań rentgenowskiej mikrotomografii komputerowej i mikroskopii optyczne
Characteristics of Rotliegend sediments in view of X-ray microtomohraphy and optical microscopy investigations
Autorzy:
Dohnalik, Marek
Ziemianin, Konrad
Powiązania:
https://bibliotekanauki.pl/articles/1833915.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
czerwony spągowiec
mikrotomografia
petrografia
własności zbiornikowe
Rotliegend
microtomography
petrography
reservoir properties
Opis:
The article presents the results of microtomographic and petrographic investigations of Rotliegend sandstones collected from core material from wells located in the area of the Fore-Sudetic Monocline in its central and northern parts and also on the border of the Fore-Sudetic Monocline and the Mogilno - Łódź Synclinorium. Three areas were selected for the study: Czarna Wieś–Parzęczewo (19 samples), Środa Wielkopolska–Kromolice (21 samples) and Siekierki–Miłosław (21 samples). The aim of the petrologic and microtomographic studies was to investigate how the different reservoir properties of sandstones will be reflected in the results of the methods used. Strong differences between samples from the region of Środa Wielkopolska–Kromolice and the other studied areas have been demonstrated. In the case of this area several key factors were noticed: the highest average value of effective porosity; the highest average content of pores belonging to class VII (pore volume subsystem classification); three times higher average value of the CT porosity coefficient and the largest length of the average chord. Also in terms of petrography (composition of grains, cement type) it is a region where major differences, especially compared to the region of Czarna Wieś–Parzęczewo, can be seen. Based on the obtained results, it was possible to rank the examined regions in terms of their reservoir properties – from the worst (Czarna Wieś–Parzęczewo) to the best (Środa Wielkopolska–Kromolice). These conclusions are also confirmed by other petrophysical analyses (eg. mercury porosimetry, permeability analysis). Combination of the obtained microtomographic and petrographic results allowed to obtain a full characterization of the investigated samples – both in terms of the mineralogical composition of grains, as well as the development of the pore space. These data, especially in combination with the results of density and porosity analyses (helium pycnometry and mercury porosimetry), open up a number of possibilities to carry out different types of modeling (porosity, permeability) both on the scale of the sample itself, as well as the scale of a single well or even the whole basin, which is crucial for creating a hydrocarbon exploration strategy.
Źródło:
Nafta-Gaz; 2020, 76, 11; 765--773
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nieniszczące badania struktury materiałów włóknisto-cementowych z użyciem mikroskopii optycznej stosowanej w metalografii
Non-destructive tests of fibre-cement materials structure with the use of optical microscopy used in metallography
Autorzy:
Schabowicz, K.
Gorzelańczyk, T.
Budzisz, R.
Roskosz, M.
Juraszek, J.
Powiązania:
https://bibliotekanauki.pl/articles/107806.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
badania nieniszczące
płyty włóknisto-cementowe
mikroskop metalograficzny
non-destructive testing
fiber-cement board
metallographic microscope
Opis:
W artykule przedstawiono propozycję zastosowania do badania płyt włóknisto-cementowych nieniszczącą metodę mikroskopową z wykorzystaniem mikroskopii optycznej stosowanej w metalografii. Badaniom poddano 4 rodzaje płyt włóknisto-cementowych poddanych procesowi zamrażania-rozmrażania, podpalania palnikiem gazowym przez 15 minut, umieszczonej w komorze cieplnej w temperaturze 230°C przez 3 godziny, a także takiej która nie została poddana obróbce termicznej ani działaniu wody. Otrzymano interesujące rezultaty badań, które pozwoliły zaobserwować zmiany zachodzące w mikrostrukturze badanych płyt pod wpływem wymienionych procesów.
The article presents the proposal for the application of non-destructive microscope method with the use of optical microscopy used in metallography. Four types of fibrous-cement fibreboards were subjected to freeze-thawing, gas torch burning for 15 minutes, placed in a heat chamber at 230°C for 3 hours, and also untreated. Interesting results have been obtained, which have allowed us to observe the changes taking place in the microstructure of the plates under investigation due to the processes mentioned.
Źródło:
Badania Nieniszczące i Diagnostyka; 2017, 4; 17-21
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Machine learning system for automated blood smear analysis
Autorzy:
Grochowski, Michał
Wąsowicz, Michał
Mikołajczyk, Agnieszka
Ficek, Mateusz
Kulka, Marek
Wróbel, Maciej S.
Jędrzejewska-Szczerska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/220750.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optical microscopy
blood cells
biophotonics
image analysis
classification
eigenfaces
neural networks
decision support
nanodiamonds
bioimaging
Opis:
In this paper the authors propose a decision support system for automatic blood smear analysis based onmicroscopic images. The images are pre-processed in order to remove irrelevant elements and to enhancethe most important ones – the healthy blood cells (erythrocytes) and the pathologic ones (echinocytes). The separated blood cells are analysed in terms of their most important features by the eigenfaces method. The features are the basis for designing the neural network classifier, learned to distinguish between erythrocytes and echinocytes. As the result, the proposed system is able to analyse the smear blood images in a fully automatic way and to deliver information on the number and statistics of the red blood cells, both healthy and pathologic. The system was examined in two case studies, involving the canine and human blood, and then consulted with the experienced medicine specialists. The accuracy of classification of red blood cells into erythrocytes and echinocytes reaches 96%.
Źródło:
Metrology and Measurement Systems; 2019, 26, 1; 81-93
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cast iron component failure: A metallurgical investigation
Autorzy:
Sudhakar, K. V.
Powiązania:
https://bibliotekanauki.pl/articles/382757.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cast iron
hardness test
optical microscopy
scanning electron microscopy
fractography
żeliwo
testy twardości
mikroskopia optyczna
mikroskop skaningowy
Opis:
A fractured nutcracker was examined for determining the root cause/s for premature fracture/failure. This is one of the common tools used typically for cracking hard nuts. In this study, metallurgical failure analysis techniques namely, visual inspection, optical microscopy, SEM, and hardness tests were used in investigating the broken product. From the metallurgical analysis, it was determined that the combined effect of low carbon equivalent and presence of inclusions contributed to the sudden fracture of the nut cracking tool.
Źródło:
Archives of Foundry Engineering; 2012, 12, 2s; 67-70
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie zanieczyszczenia powietrza pyłem azbestu w obiektach budowlanych przy zastosowaniu mikroskopii optycznej - strategia poboru prób powietrza
Measurement of asbestos dust contamination of the buildings indoor air using optical microscopy - strategy of sampling
Autorzy:
Obmiński, A.
Powiązania:
https://bibliotekanauki.pl/articles/183030.pdf
Data publikacji:
2006
Wydawca:
Instytut Techniki Budowlanej
Tematy:
pył azbestowy
powietrze wewnętrzne
zanieczyszczenie powietrza
badanie laboratoryjne
mikroskopia optyczna
pobieranie próbek
pomiar
stężenie
Opis:
Przedstawiono główne kierunki badań pozwalających określić liczbę respirabilnych włókien azbestu w powietrzu badanych obiektów. Opisano cel badań, ich rodzaj, liczbę i usytuowanie próbek w budynku, warunki poboru oraz sposób przygotowania pomieszczeń do badań.
The main directions of research works allowing to define the number of countable asbestos fibers in the buildings indoor air are presented. The aim of tests, their types, number and localization of samples in building, condition of sampling and preparation of compartment for test are described.
Źródło:
Prace Instytutu Techniki Budowlanej; 2006, R. 35, nr 4, 4; 63-71
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of X-Ray Microtomography and Optical Microscopy to Determine the Microstructure of Concrete Penetrated by Carbon Dioxide
Zastosowanie mikrotomografii komputerowej i mikroskopii optycznej do oceny mikrostruktury betonów poddanych działaniu CO2
Autorzy:
Ranachowski, Z.
Jóźwiak-Niedźwiedzka, D.
Ranachowski, P.
Rejmund, F.
Dąbrowski, M.
Kudela, S. jr.
Dvorak, T.
Powiązania:
https://bibliotekanauki.pl/articles/351864.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cement-matrix composites
concrete deterioration
X-ray tomography
microscopic analysis
concrete microstructure
kompozyty cementowe
zniszczenie betonu
tomografia rentgenowska
analiza mikroskopowa
mikrostruktura betonu
Opis:
In the paper two advanced methods for testing cement based composites are described and compared. These are X-ray microtomography and optical microscopy. Microtomography supplies three-dimensional images of small concrete specimens. In the tomograms all cracks, pores and other voids and inclusions, that exceed a few micrometers, are shown. Such visualisation can become a valuable tool for analysis of the basic material properties. Images obtained on thin sections and analysed with various methods on optical microscopes supply additional information on material microstructure that cannot be obtained in tomograms. For example it is relatively easy to determine zone penetrated by CO2 ingress. These two methods, presented on examples of tests, complete each another in order to supply a set of information on composition and defects of tested composite materials.
W artykule przedstawiono dwie nowoczesne metody analizy struktury materiałów kompozytowych ze spoiwem na bazie cementu. Są to mikrotomografia komputerowa oraz optyczna analiza cienkich szlifów. Mikrotomografia pozwala na uzyskanie trójwymiarowych obrazów niewielkich próbek betonowych. Na tomogramach widoczne są układy rys, porów i innych pustek, których wymiary przekraczają kilka mikrometrów. Przestawienie tych obiektów w przestrzeni jest ważnym narzędziem do analizy podstawowych właściwosci materiału. Obrazy uzyskane na cienkich szlifach w mikroskopie optycznym, analizowane następnie różnymi metodami, dostarczają dodatkowych informacji o mikrostrukturze materiału, które nie mogą być dostrzeżone na tomogramach. Stosunkowo łatwo jest np. uzyskac obrazy stref skarbonatyzowanej matrycy cementowej. Obie przedstawione metody uzupełniają się wzajemnie i pozwalają na otrzymanie zbioru informacji o składzie i defektach badanych materiałów kompozytowych.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 4; 1441-1447
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikroskopowe metody badania cytoszkieletu
Microscopy techniques for cytoskeleton resarch
Autorzy:
Nowak, Natalia
Pomorski, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/1033968.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Przyrodników im. Kopernika
Tematy:
cytoskeleton
electron microscopy
immunocytochemistry
molecular probes
optical microscopy
superresolution microscopy
cytoszkielet
immunocytochemia
mikroskopia elektronowa
mikroskopia optyczna
mikroskopia superrozdzielcza
sondy molekularne
Opis:
Cytoszkielet to sieć białkowych polimerów oraz związanych z nimi setek białek motorycznych, regulatorowych i łączących cytoszkielet z innymi strukturami komórkowymi. Rozwój wiedzy o cytoszkielecie jest nierozerwalnie zwiększany z postępem technik mikroskopowych używanych do jego obserwacji. Początki tych badań to niespecyficzne, nieskomplikowane barwienia utrwalonego materiału biologicznego, które później rozwinęły się w nowoczesną mikroskopię strukturalną, pozwalającą na precyzyjne znakowanie określonych białek tworzących cytoszkielet, badanie ich stanu fizjologicznego czy też oddziaływań cytoszkieletu z luźno związanymi białkami błony czy cytoplazmy. Obecnie możliwe jest nie tylko obrazowanie struktury i funkcji cytoszkieletu ze znacznie lepszą rozdzielczością przestrzenną, ale także prowadzenie tych obserwacji na żywym materiale biologicznym. Z drugiej strony, stabilność cytoszkieletu umożliwia poszukiwanie nowych metod jego obrazowania, co niewątpliwie należy do kół napędowych postępu, jaki dokonał się i wciąż dokonuje się w dziedzinie mikroskopii.
Cytoskeleton is basically a network of protein polymers, but it also contains thousands of motor, regulatory and scaffolding proteins that interact with this network. Discoveries related to the cytoskeleton were strictly connected to the development of microscopy techniques used to observe the cytoskeletal structures. At first, the imaging involved only unspecific, very simple staining of fixed material. Then, the methods evolved into advanced structural microscopy, which enabled accurate detection of specific cytoskeletal proteins, their physiological status, and interactions with loosely bound membrane and cytoplasmic proteins. Today, it is possible not only to visualize the structure and function of the cytoskeleton with better spatial resolution but also to perform the imaging in vivo on live biological specimens. On the other hand, one should also notice that observations of the stable, well defined cytoskeletal structures from their very discovery have continuously stimulated the progress in the microscopy field.
Źródło:
Kosmos; 2018, 67, 1; 219-232
0023-4249
Pojawia się w:
Kosmos
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody mikroskopowe w ocenie procesów wykończania wyrobów włókienniczych
Evaluation of finishing processes for textile products using the microscopic methods
Autorzy:
Machnowski, Waldemar
Wrzosek, Henryk
Powiązania:
https://bibliotekanauki.pl/articles/1818683.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Skórzanego
Tematy:
mikroskopia optyczna
SEM
skaningowa mikroskopia elektronowa
bawełna
jakość tekstyliów
procesy wykończenia tekstyliów
optical microscopy
scanning electron microscopy
cotton
textiles quality
textile finishing processes
Opis:
Badanie wyrobów włókienniczych odgrywa istotną rolę w systemie zapewnienia jakości tekstyliów, a także w pracach nad rozwojem nowych technologii i produktów włókienniczych. Istnieje wiele metod oceny struktury i właściwości włókien i wyrobów włókienniczych. Bardzo ważne miejsce wśród tych metod zajmują techniki mikroskopowe, w szczególności mikroskopia optyczna i skaningowa mikroskopia elektronowa (SEM). W artykule podano krótki przegląd możliwych zastosowań metod mikroskopowych do analizy efektów niektórych operacji wytwarzania tekstyliów. Wykorzystanie mikroskopu optycznego umożliwiło identyfikację przyczyn powodujących nierównomierność barwy wyrobów bawełnianych. Z przeglądu literatury oraz doświadczeń własnych autorów wynika, że metody mikroskopowe stanowią cenne narzędzie w badaniu włókien i wyrobów włókienniczych.
Fabric testing plays an important role in the quality assurance system and in the development of new textile technologies and products. There are many test methods used to evaluate the structure and properties of fibers and textile materials. Among these methods, microscopic techniques – especially optical microscopy and scanning electron microscopy (SEM) – are one of the most important methods. This paper provides a brief overview of the possible uses the microscopic methods for determining the results of some textile manufacturing processes. A review of the literature and the authors experiences in this field indicate that microscopic methods are a valuable tool for the testing and assessing the performance of fibers and textile products.
Źródło:
Technologia i Jakość Wyrobów; 2020, 65; 4--20
2299-7989
Pojawia się w:
Technologia i Jakość Wyrobów
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Two-body wear simulation influence on some direct and indirect dental resin biocomposites : A qualitative analysis
Autorzy:
Caracostea, A.
Morar, N.
Florea, A.
Soanca, A.
Badea, M. E.
Powiązania:
https://bibliotekanauki.pl/articles/307539.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
mikroskop elektronowy skaningowy
skaningowy mikroskop elektronowy
mikroskop optyczny
system CAD
biokompozyt
scanning electron microscopy
optical microscopy
two-body wear
CAD system
advanced biocomposites
Opis:
Purpose: The aim of this study was to qualitatively assess the outcomes of two in vitro aging methods, thermal-cycling and twobody wear simulation accomplished with a dual-axis chewing device, on the surface characteristics of eight direct and indirect dental resin biocomposites. Methods: Eighty mesial-occlusal-distal dental cavities were restored with four direct nanohybrid composite materials and with four nano- and micro-hybrid lab-fabricated resin composite inlays. After the restored teeth were subjected to thermal-cycling and wear simulation based on mechanical loading, the surface texture features of the restorations were separately analysed for each of the methods, on epoxy resin models using a digital camera, computer-aided-design system, optical stereo-microscopy and scanning electron microscopy. Results: All the dental restorative resin based composites used in this investigation displayed different cyclic wear patterns after undergoing mechanical loading. After thermal-cycling, the group of resin composite inlays showed a better adaptation, a smoother and more polished occlusal surface compared with direct restorative materials. Only two of direct nanohybrid resin composites performed better after two aging methods. One nanohybrid and the other two microhybrid resin inlays did not perform as expected when they were subjected to simulated wear compared to the rest of test materials. Conclusions: The use of the two-body wear simulation method revealed important information about the behavior of the dental resin-based composites when multiple oral factors are involved in a lab-simulated condition. Furthermore, the macro- and micro-morphological analysis showed different abrasion patterns among the materials being tested according to the filler percentage and distribution of the particles within the resin matrix.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 3; 61-72
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania mieszalności węglanu 2”-3”-difluoro-4”- pentyloterfenyl-4-ylo propylowego ze związkami ferroelektrycznymi
Miscibility studies of 2”-3”-difluoro-4”-pentylterphenyl-4-yl carbonate with ferroelectric compounds
Autorzy:
Kurp, K.
Czerwiński, M.
Tykarska, M.
Powiązania:
https://bibliotekanauki.pl/articles/209522.pdf
Data publikacji:
2015
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
chemia
ciekłe kryształy
faza ferroelektryczna
badania mieszalności
mikroskopia optyczna
skok helisy
chemistry
liquid crystals
ferroelectric phase
miscibility studies
optical microscopy
helical pitch
Opis:
Trzy trójpierścieniowe związki chiralne tworzące fazę ferroelektryczną były domieszkowane niechiralnym difluoropodstawionym węglanem o rdzeniu terfenylowym. Zbadano wpływ struktury i ilości węglanu na stabilność iskok helisy fazy ferroelektrycznej w mieszaninach dwuskładnikowych. Stwierdzono, że stabilność termiczna fazy SmC* związków chiralnych ulega zwiększeniu. Dodawanie węglanu z rdzeniem terfenylowym w dwóch przypadkach nieznacznie zwiększa skok helisy, a w jednym nieznacznie go zmniejsza.
Three chiral compounds, containing three aromatic rings in a rigid core, forming ferroelectric phase were doped with non chiral difluorosubstituted terphenyl carbonate compound. The influence of the structure and the amount of terphenyl carbonate compound on the stability and helical pitch of the ferroelectric phase in binary mixtures was examined. It was found that thermal stability of the SmC* phase of chiral compounds has increased. Addition of terphenyl carbonate compound slightly increases the helical pitch (except for one of the binary mixture).
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2015, 64, 3; 27-34
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nagroda Nobla z chemii w 2014 roku za rozwój wysokorozdzielczej mikroskopii fluorescencyjnej
The Nobel Prize in chemistry 2014 for the development of super-resolved fluorescence microscopy
Autorzy:
Frączkowska, K.
Powiązania:
https://bibliotekanauki.pl/articles/261752.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
Nagroda Nobla 2014
STED
Stefan Hell
Eric Betzig
William Moerner
limit dyfrakcji Abbego
mikroskopia optyczna
Nobel Prize 2014
Abbe’s diffraction limit
optical microscopy
Opis:
Możliwości obrazowania za pomocą mikroskopów optycznych przez długi czas były ograniczone przez tzw. limit dyfrakcji Abbego. Skutkiem istnienia tej granicy jest fakt, że za pomocą mikroskopii świetlnej nie można osiągnąć lepszej rozdzielczości niż połowa długości fali światła. Za obejście tej granicy przy pomocy cząsteczek fluorescencyjnych i zastosowanie specjalnej techniki obrazowania mikroskopowego, Królewska Szwedzka Akademia Nauk zdecydowała o przyznaniu Nagrody Nobla z chemii w 2014 roku trzem naukowcom – Stefanowi W. Hellowi, Williamowi E. Moernerowi oraz Ericowi Betzigowi. Ich prace doprowadziły do skonstruowania mikroskopu fluorescencyjnego o wysokiej rozdzielczości oraz przyczyniły się do rozwoju technik obrazowania pojedynczych molekuł (stimulated emission depletion microscopy STED). Nastąpił wtedy prawdziwy przełom w technikach mikroskopowych, który umożliwił mikroskopii optycznej spojrzenie w nanoświat.
The imaging capabilities using optical microscopes for a long time have been limited by the so-called Abbe’s diffraction limit. According to it, light microscopy cannot achieve resolution better than a half of the light wavelength. For overcoming this limit by using the fluorescent molecules and special microscopic imaging techniques, The Royal Swedish Academy of Sciences has decided to award Stefan W. Hell, William E. Moerner and Eric Betzig the Nobel Prize in Chemistry in 2014. Their works led to the development of super-resolution fluorescence microscopy and single-molecule imaging techniques (stimulated emission depletion microscopy STED). It was a real breakthrough in microscopy techniques that enabled optical microscopy look into the nanoworld.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2014, 20, 4; 238-245
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Understanding technical cleanliness: importance, assessment, maintenance
Autorzy:
Faber, Joanna
Brodzik, Krzysztof
Nycz, Marta
Powiązania:
https://bibliotekanauki.pl/articles/2097549.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
technical cleanliness
component cleanliness code
contaminations
particles
optical microscopy
SEM
scanning electron microscopy
czystość techniczna
kod czystości komponentu
zanieczyszczenia
cząstki
mikroskopia optyczna
skaningowa mikroskopia elektronowa
Opis:
Development of the automotive industry, including so-called dowsizing and rightsizing, entails the need to ensure, and hence to verify, the stringent cleanliness levels of an increasing number of car components. The assurance of proper cleanliness level requires knowledge of the entire production process and precise information on the contaminants that will allow to identify their sources. Obtaining reliable cleanliness information requires establishing of many different factors, i. a. selection of proper contamination extraction and collection technique, proper parameters of extraction, validation of extraction procedure, methods of particles analysis. Analytical techniques which are implemented include gravimetric, optical microscopy and advanced techniques like scanning electron microscopy. This work present’s actual state of knowledge regarding technical cleanliness analysis of components. Important aspects of QA&QC in technical cleanliness assessment are also discussed.
Źródło:
Combustion Engines; 2021, 60, 3; 41--50
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Self-healing cement materials – microscopic techniques
Samoleczące tworzywa cementowe – techniki mikroskopowe
Autorzy:
Dudek, Marta
Powiązania:
https://bibliotekanauki.pl/articles/390873.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
optical microscopy
scanning electron microscopy
tensile stage
self-healing cementitious materials
micro-mechanical properties
mikroskop optyczny
elektronowy mikroskop skaningowy
stolik naprężeniowy
samoleczące tworzywa cementowe
właściwości mikromechaniczne
Opis:
The article presents a general classification of intelligent materials with self-healing (self-repairing) properties, focusing on self-healing cementitious materials. The purpose of the paper is to describe the prospects of two of the most popular micro-observation techniques, i.e. with the use of an optical and scanning electron microscope. In addition, it describes the advantages of using a tensile stage mounted in the microscope chamber for testing self-healing materials. The advantages and disadvantages of these devices have been characterized, and the results of preliminary research have been provided. The tests include the optical microscopy and scanning electron microscopy observations of the microstructure of cracks before and after the process of healing. They were carried out using ZEISS Discovery V20 optical microscope and ZEISS EVO-MA 10 scanning electron microscope on mortar samples modified with macro capsules filled with polymer. In addition to observations, chemical analysis was performed with the use of an EDS detector. The microscopic observations and chemical analyses provide the basis for assessing the effectiveness of the self-healing process, showing that the crack has been healed. Moreover, the preliminary results of the tests of micro-mechanical properties, carried out with the use of a tensile stage, have been described. The problems of using this research technique are also listed. This study shows the usefulness of this kind of tests for microcapsules for self-healing materials.
Artykuł przedstawia ogólną klasyfikację materiałów inteligentnych o właściwościach samoleczących (samonaprawiających), ze szczególnym uwzględnieniem samoleczących tworzyw cementowych. Celem niniejszej publikacji jest przedstawienie dwóch najpopularniejszych technik mikroobserwacji, tj. mikroskopii optycznej i skaningowej. Ponadto opisano, jakie możliwości w badaniach samoleczących materiałów daje stolik naprężeniowy, zamontowany w komorze mikroskopu. Scharakteryzowano zalety i wady tych urządzeń oraz przedstawiono wyniki wstępnych badań. Badania obejmują obserwacje mikrostruktury pęknięć przed i po procesie gojenia, zarówno w mikroskopie optycznym jak i skaningowym. Przeprowadzono je przy użyciu mikroskopu optycznego ZEISS Discovery V20 i skaningowego mikroskopu elektronowego ZEISS EVO-MA 10, na próbkach zaprawy modyfikowanej makrokapsułkami wypełnionymi polimerem. Oprócz obserwacji wykonano analizę chemiczną z wykorzystaniem detektora EDS. Obserwacje mikroskopowe i analiza chemiczna dają podstawę do oceny skuteczności procesu samoleczenia, wykazując, że pęknięcie zostało zagojone. Opisano również wstępne wyniki badań właściwości mikromechanicznych, przeprowadzonych z wykorzystaniem stolika naprężeniowego. Wymieniono także trudności związane z wykorzystaniem tej techniki badawczej. Artykuł przedstawia przydatność tego rodzaju testów dla mikrokapsułek używanych do modyfikacji materiałów samoleczących.
Źródło:
Budownictwo i Architektura; 2020, 19, 2; 33-40
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aging of carbon nanotube-filled fluoroelastomer in oil-based drilling fluid
Starzenie fluoroelastomeru napełnionego nanorurkami węglowymi w płuczce wiertniczej na bazie oleju
Autorzy:
Heidarian, J.
Powiązania:
https://bibliotekanauki.pl/articles/1205317.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
carbon nanotube
fluoroelastomer
carbon black
oil-based drilling mud
aging test
atomic force microscopy
optical microscopy
nanorurki węglowe
sadza węglowa
płuczka wiertnicza
test starzeniowy
mikroskopia sił atomowych
mikroskopia optyczna
Opis:
Carbon nanotube (CNT)-, carbon black (CB)-filled fluoroelastomer (FE) and unfilled FE compounds were prepared (CNT/FE, CB/FE and FE). The oil-based drilling mud (OBD) aging resistance of these elastomers were assessed by tests of atomic force microscopy (AFM), optical microscopy and X-ray diffractometry (XRD). Weight gain, swelling and hardness were also determined. The whole conclusion is that CNT/FE can be used as O-rings in OBD drilling while FE and CB/FE can not.
Metodami mikroskopii optycznej, mikroskopii sił atomowych (AFM) i dyfraktometrii rentgenowskiej (XRD) badano odporność starzeniową kompozytów na bazie fluoroelastomeru (FE) napełnianego nanorurkami węglowymi (CNT) lub sadzą węglową (CB), poddanych działaniu płuczki wiertniczej na bazie oleju (OBD). Oznaczano też przyrost masy, stopień spęcznienia i twardość próbek poddanych starzeniu w środowisku płynu wiertniczego. Stwierdzono, że fluoroelastomer napełniony nanorurkami węglowymi jest odporny na działanie płynu wiertniczego i można go stosować w materiale uszczelek w urządzeniach wiertniczych wykorzystujących płuczki na bazie oleju.
Źródło:
Polimery; 2018, 63, 3; 191-212
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Graph-based segmentation with homogeneous hue and texture vertices
Autorzy:
Ngo, Lua
Han, Jae-Ho
Powiązania:
https://bibliotekanauki.pl/articles/2033896.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
image segmentation
deep neural network
electron microscopy
optical coherence tomography
pattern recognition
Opis:
This work presents an automated segmentation method, based on graph theory, which processes superpixels that exhibit spatially similarities in hue and texture pixel groups, rather than individual pixels. The graph shortest path includes a chain of neighboring superpixels which have minimal intensity changes. This method reduces graphics computational complexity because it provides large decreases in the number of vertices as the superpixel size increases. For the starting vertex prediction, the boundary pixel in first column which is included in this starting vertex is predicted by a trained deep neural network formulated as a regression task. By formulating the problem as a regression scheme, the computational burden is decreased in comparison with classifying each pixel in the entire image. This feasibility approach, when applied as a preliminary study in electron microscopy and optical coherence tomography images, demonstrated high measures of accuracy: 0.9670 for the electron microscopy image and 0.9930 for vitreous/nerve-fiber and inner-segment/outer-segment layer segmentations in the optical coherence tomography image.
Źródło:
Optica Applicata; 2021, 51, 4; 541-549
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the electrolytically polished skeletal dentures surfaces using various nano- and microscopic technologies
Autorzy:
Dąbrowa, Tomasz
Majstrzyk, Wojciech
Tamulewicz, Magdalena
Piasecki, Tomasz
Kunicki, Piotr
Więckiewicz, Włodzimierz
Gotszalk, Teodor
Powiązania:
https://bibliotekanauki.pl/articles/306706.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
chropowatość powierzchni
skaningowa mikroskopia elektronowa
proteza ruchoma
mikroskopia skaningowa
surface roughness
scanning electron microscopy
removable partial denture
scanning probe microscopy
optical profilometry
Opis:
The surface roughness of the dental restorations is significant to the denture plaque adhesion. Methods: In this work, we present the complex analysis of the electropolished CoCrW alloy remanium® star (Dentaurum, Germany) samples with laserengraved fiducial marks performed using complementary set of micro- and nanoscopic techniques: optical profilometry (OP), atomic force microscopy (AFM), scanning electron microscopy (SEM) and focused ion beam (FIB) milling. Results: Both mean and RMS roughness of the samples were reduced by electopolishing process, however, the results obtained using OP and AFM exhibited some discrepancies. This was caused by the relatively high local protruding defects developed on the processed surface. The cross-sections of the protrusions were made to analyze the cause of their formation as the EDS elemental content maps revealed that their composition was uniform. We also analyzed the local roughness in the smaller areas free from the defects. Conclusions: In that case, both OP and AFM techniques delivered the same results. Analysis of results showed that various methods used for the surface roughness evaluation have to be used simultaneously to obtain complete and true analysis of the technological CoCrW samples.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 4; 123-129
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the structure of archeological objects - ceramic pottery
Analiza struktury obiektów archeologicznych - naczyń ceramicznych
Autorzy:
Riegert, D.
Konopka, K.
Powiązania:
https://bibliotekanauki.pl/articles/354078.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
glina
domieszki
naczynie ceramiczne
mikroskopia stereoskopowa
pottery
clay
admixtures
stereoscopic microscopy
optical profilometry
Opis:
The aim of the present study was to check whether the research methods used in materials engineering could be useful for examining archeological ceramic pottery. The experiments were conducted with the use of stereoscopic microscopy, scanning electron microscopy, and optical profilometry. The examined material included pieces of the archeological clay vessels excavated from various sites and dated at two various historical periods. The first group includes samples from the 5th century B.C. from Biehla (Germany) and Starosiedle (Poland), the second group consists of fragments of vessels of the 10th century A.D. from Starosiedle (Poland) and Rosenhof (Germany). The structure of the matrix and the mineral admixtures distributed throughout it were analyzed on the cross-sections of the archeological material. The examinations were performed using the fractographic method and optical profilometery, which permitted determine the shapes and morphology of the admixtures, examine their embedding in the matrix material (clay), and also revealing possible layers or delaminations within the matrix.
Głównym celem pracy przedstawionej w artykule było wykorzystanie metod badawczych stosowanych w inżynierii materiałowej do badania ceramiki archeologicznej. Do badań zastosowano mikroskopię stereoskopową, skaningową mikroskopię elektronową oraz profilometrię optyczną. Materiałem do badań były fragmenty glinianych naczyń archeologicznych pochodzęcych z róznych okresów historycznych i z różnych miejsc, odpowiednio: Biehla i Starosiedle - V w. p.n.e.; Starosiedle i Rosenhof - × w. Analizie poddana była budowa osnowy oraz rozmieszczone w niej domieszki mineralne. W tym celu zastosowano badania faktograficzne i badania przy uzyciu profilometru optycznego powierzchni płaskich powstałych w wyniku cięcia materiału archeologicznego. Badania te pozwoliły na obserwację kształtu, morfologii domieszek, a także stopnia "obtoczenia" ich przez material osnowy — glinę, oraz obecności warstw i rozwarstwień w osnowie.
Źródło:
Archives of Metallurgy and Materials; 2011, 56, 1; 163-170
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Scanning optical and electron microscopes with computer image acquisition
Autorzy:
Konstankiewicz, K.
Pukos, A.
Powiązania:
https://bibliotekanauki.pl/articles/25623.pdf
Data publikacji:
1995
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
electron microscope
scanning optical microscope
microscopic method
tandem scanning reflected light microscope
computer image analysis
scanning electron microscopy
biological material
rotary microtome
confocal microscopy
Źródło:
International Agrophysics; 1995, 09, 4
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of a hybrid Atomic Force microscope and Optical Tweezers apparatus
Autorzy:
Zembrzycki, K.
Pawłowska, S.
Nakielski, P.
Pierini, F.
Powiązania:
https://bibliotekanauki.pl/articles/31343079.pdf
Data publikacji:
2016
Wydawca:
Instytut Podstawowych Problemów Techniki PAN
Tematy:
optical tweezers
atomic force microscopy (AFM)
AFM/OT
mikroskopia sił atomowych
szczypce optyczne
Opis:
The role of mechanical properties is essential to understand molecular, biological materials and nanostructures dynamics and interaction processes. Atomic force microscopy (AFM), due to its sensitivity is the most commonly used method of direct force evaluation. Yet because of its technical limitations this single probe technique is unable to detect forces with femtonewton resolution. In this paper, we present the development of a combined atomic force microscopy and optical tweezers (AFM/OT) instrument. The system is based on a commercial AFM and confocal microscope. The addition of three lasers along with beam shaping and steering optics, on which the optical tweezer is based upon, provide us with the ability to manipulate small dielectric objects suspended in a fluid. Additionally, this same device allows for direct displacement and force measurement with very high resolution and accuracy in the same AFM scanning zone. We have also fitted a laser and a set of filters to observe fluorescent samples appropriately exited. We show that this is a great improvement of a standalone AFM force resolution and more so opens a way to conduct experiments using a hybrid double probe technique with high potential in nanomechanics, molecules manipulation and biological studies. This paper describes in detail the construction of all the modules such as the trapping laser optics, detection laser optics and the fluorescence module. Also, due to its importance on the performance of the equipment, the electronics part of the detection system is described. In the following chapters the whole adjustment and calibration is explained. The performance of the apparatus is fully characterized by studying the ability to trap dielectric objects and quantifying the detectable and applicable forces. The setting and sensitivity of the particle position detector and force sensor is shown. We additionally describe and compare different optical tweezer calibration methods. In the last part we show the ability of our instrument to conduct experiments using the proposed double-probe technique, in this case to study interaction forces between two particles.
Pomiary własności mechanicznych i sił w mikro i nanoskali mają bardzo ważne znaczenie w badaniach dynamiki i oddziaływań materiałów biologicznych i nanostruktur. Mikroskopia sił atomowych (ang. AFM), z uwagi na swoją czułość, jest najczęściej używaną techniką do bezpośredniego pomiaru sił. Jednak z powodu swoich ograniczeń nie jest w stanie mierzyć sił z rozdzielczością w zakresie femtonewtonów. Takie możliwości stwarza metoda optyczna oparta na tzw. szczypcach optycznych (ang. OT). Z drugiej strony z uwagi na fizyczne ograniczenia tej metody pomiary charakteryzujące oddziaływujące powierzchnie w niewielkich odległościach, nadal wymagają stosowania mikroskopii sił atomowych. W poniższej pracy opisujemy unikalną konstrukcję hybrydową bazującą na połączeniu obu technik w jednym systemie. Skonstruowany system (AFM/OT) oparty jest na autorskiej modyfikacji komercyjnego mikroskopu AFM (firmy NT-MDT) i jest możliwy do zastosowania zasadniczo w każdym innym dostępnym na rynku mikroskopie typu AFM. Modyfikacja polega zasadniczo na budowie dodatkowego systemu optycznego formującego wiązki trzech laserów, na których bazują szczypce optyczne. Umożliwia to manipulację małymi obiektami dielektrycznymi zawieszonymi w płynie i precyzyjną detekcję ich położenia. Dzięki takiej modyfikacji stworzony system AFM/OT pozwala na bezpośrednie pomiary przemieszczenia oraz siły z bardzo dużą rozdzielczością i dokładnością w obszarze działania sondy AFM. Dodatkowo system został wyposażony w laser i elementy optyczne pozwalające na pobudzanie i detekcję fluorescencji odpowiednio przygotowanych obiektów. Wykazujemy, że ten instrument istotnie poprawia zakres i rozdzielczość sił mierzonych za pomocą standardowego mikroskopu AFM, jak również otwiera drogę do przeprowadzania eksperymentów z użyciem hybrydowej techniki dwóch sond, mającej wysoki potencjał zastosowań w nanomechanice, badaniach biologicznych i nanomanipulacji. Niniejsza praca przedstawia szczegóły konstrukcyjne zbudowanych modułów szczypiec optycznych, jak i układ elektroniczny pozwalający na precyzyjne pomiary przemieszczeń obiektów uwięzionych przez szczypce optyczne. W kolejnych partiach pracy przedstawiona jest procedura dostrajania układu optycznego i metodyka kalibracji systemu pomiaru sił i przemieszczeń. Podstawowe parametry aparatury zostają w pełni scharakteryzowane poprzez zbadanie jej zdolności do manipulacji dielektrycznymi obiektami oraz do mierzeni wywieranych na nie sił. Dodatkowo przedstawiamy opis i porównanie różnych metod kalibracji szczypiec optycznych. W ostatniej części pracy przedstawiamy na przykładzie pomiaru oddziaływań bliskiego kontaktu dwóch cząstek koloidalnych potencjał naszego instrumentu dla przeprowadzania pomiarów z jednoczesnym użyciem techniki dwóch sond (AFM/OT).
Źródło:
IPPT Reports on Fundamental Technological Research; 2016, 2; 1-58
2299-3657
Pojawia się w:
IPPT Reports on Fundamental Technological Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Femtosecond photonics for three-dimensional high density optical data storage
Autorzy:
Kawata, Y.
Tsuji, M.
Inami, W.
Powiązania:
https://bibliotekanauki.pl/articles/384323.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
femtosecond pulse laser
two-photon absorption
confocal microscopy
optical memory
Opis:
We have developed a high density optical data storage by using two-photon absorption process. We have developed a multilayered medium in which photosensitive layers and transparent pressure-sensitive adhesives layer were piled up alternately. We also demonstrate the development of compact high power fiber laser as a light source of high density optical data storage system.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 9-11
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Głowica detekcyjna do pomiaru energii promieniowania optycznego na potrzeby mikroskopii
Detection head for measurements of radiation energy designed for microscopy
Autorzy:
Mikołajczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/208347.pdf
Data publikacji:
2009
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
detekcja sygnałów optycznych
mikroskopia zakresu okna wodnego
wzmacniacz ładunkowy
promieniowanie optyczne
pomiar energii
pomiar promieniowania optycznego
detection of optical signals
water window microscopy
charge-sensitive preamp
optical radiation
energy measurement
optical radiation measurement
Opis:
W artykule przedstawiono projekt i wyniki badań parametrów dwuwidmowej głowicy detekcyjnej przeznaczonej do pomiaru energii promieniowania w zakresie długości fal od 2 nm do 4 nm. Ze względu na specyfikę tego promieniowania w głowicy zdecydowano się zastosować dwa tory pomiarowe wyposażone w różne filtry absorpcyjne. Dzięki odpowiedniemu doborowi charakterystyk transmisyjnych tych filtrów i ich skorelowaniu uzyskano możliwość pomiaru energii promieniowania w rozpatrywanym zakresie długości fal.
The paper presents a project and investigation results of a two-spectral detection head. The head provides measurement of radiation energy in the water window wavelength range. In the instrument, the two measurement channels with different absorption filters were applied. It was argued by absorption virtues of the spectrum. The selection and correlation of the filter transmissions makes it possible to correctly measure energy radiation in the "water widow" range.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2009, 58, 1; 339-349
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Complexing Agent on the Structural, Optical and Electrical Properties of Polycrystalline Indium Sulfide Thin Films Deposited by Chemical Bath Deposition
Autorzy:
Göde, F.
Kariper, İ.
Güneri, E.
Ünlü, S.
Powiązania:
https://bibliotekanauki.pl/articles/1031534.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
scanning electron microscopy
thin film
optical constant
growth from solutions
Opis:
Indium sulfide (β-In₂S₃) thin films are synthesized by chemical bath deposition method using three different complexing agent volumes, triethanolamine (TEA) (0.30, 0.45, and 0.60 ml). The effect of complexing agent on the structural, morphological, optical and electrical properties of chemically deposited indium sulfide (β-In₂S₃) thin films have been investigated in this work. The characterization of the present films is carried out using X-ray diffraction, scanning electron microscopy, UV-vis spectroscopy and electrical measurements. The structure of the films is polycrystalline with a cubic phase of β-In₂S₃. Firstly, the band gap of the film decreases from 3.74 eV to 3.15 eV by adding 0.30 ml TEA. Then, it increases to 3.79 eV with increasing TEA. Nevertheless, previously, the refractive index of the films increases from 2.13 to 2.67 for the 0.30 mL TEA and then it decreases to the value of 2.11 with increasing TEA. Extinction coefficient, real and dielectric constant of the films are calculated using the absorption and transmittance spectra. Firstly, the electrical resistivity of the films decreases from 3.46×10⁸ Ω cm to 1.33×10⁷ Ω cm by adding 0.30 ml TEA. Then, it increases to the value of 2.16×10⁹ Ω cm with increasing TEA. Eventually, the more conductive film with worm-like morphology detected from the scanning electron microscopy is synthesized using 0.30 ml TEA. These results show that complexing agent has an important effect on the structural, morphological, optical and electrical properties of the deposited films.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 527-530
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Photosensitization of TiO2 P25 with CdS Nanoparticles for Photocatalytic Applications
Autorzy:
Trenczek-Zając, A.
Banaś, J.
Świerczek, K.
Zazakowny, K.
Radecka, M.
Powiązania:
https://bibliotekanauki.pl/articles/352507.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
semiconductors
X-ray diffraction
transmission electron microscopy TEM
catalytic properties
optical properties
Opis:
A TiO2/CdS coupled system was prepared by mixing the TiO2 P25 with CdS synthesized by means of the precipitation method. It was found that the specific surface area (SSA) of both components is extremely different and equals 49.5 for TiO2 and 145.4 m2·g-1 for CdS. The comparison of particle size distribution and images obtained by means of transmission electron microscopy (TEM) showed agglomeration of nanocomposites. X-ray diffraction (XRD) patterns suggest that CdS crystallizes in a mixture of cubic and hexagonal phases. Optical reflectance spectra revealed a gradual shift of the fundamental absorption edge towards longer wavelengths with increasing CdS molar fraction, which indicates an extension of the absorption spectrum of TiO2. The photocatalytic activity in UV and UV-vis was tested with the use of methyl orange (MO). The Langmuir–Hinshelwood model described well the photodegradation process of MO. The results showed that the photocatalytic behaviour of the TiO2/CdS mixture is significantly better than that of pure nanopowders.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2A; 841-849
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
LCoS spatial light modulators as active phase elements of full-field measurement systems and sensors
Autorzy:
Kujawinska, M.
Porras-Aguilar, R.
Zaperty, W.
Powiązania:
https://bibliotekanauki.pl/articles/221745.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
spatial light modulators
liquid crystals on silicon
phase modulation
optical metrology
active interferometry
active microscopy
digital holography
Opis:
Spatial light modulators (SLM) are devices used to modulate amplitude, phase or polarization of a light wave in space and time. Current SLMs are based either on MEMS (micro-electro-mechanical system) or LCD (liquid crystal display) technology. Here we report on the parameters, trends in development and applications of phase SLMs based on liquid crystal on silicon (LCoS) technology. LCoS technology was developed for front and rear projection systems competing with AMLCD (active matrix LCD) and DMD (Digital Mirror Device) SLM. The reflective arrangement due to silicon backplane allows to put a high number of pixels in a small panel, keeping the fill-factor ratio high even for micron-sized pixels. For coherent photonics applications the most important type of LCoS SLM is a phase modulator. In the paper at first we describe the typical parameters of this device and the methods for its calibration. Later we present a review of applications of phase LCoS SLMs in imaging, metrology and beam manipulation, developed by the authors as well as known from the literature. These include active and adaptive interferometers, a smart holographic camera and holographic display, microscopy modified in illuminating and imaging paths and active sensors.
Źródło:
Metrology and Measurement Systems; 2012, 19, 3; 445-458
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-36 z 36

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies