Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "noise assessment metrics" wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
Investigations of Auditory Filters Based Excitation Patterns for Assessment of Noise Induced Hearing Loss
Autorzy:
Al-Dayyeni, W. S.
Sun, P.
Qin, J.
Powiązania:
https://bibliotekanauki.pl/articles/176368.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
noise induced hearing loss
excitation pattern
basilar membrane motion
auditory filter
noise assessment metrics
Opis:
Noise induced hearing loss (NIHL) as one of the major avoidable occupational related health issues has been studied for decades. To assess NIHL, the excitation pattern (EP) has been considered as one of the mechanisms to estimate the movements of the basilar membrane (BM) in the cochlea. In this study, two auditory filters, dual resonance nonlinear (DRNL) filter and rounded-exponential (ROEX) filter are applied to create two EPs, the velocity EP and the loudness EP respectively. Two noise hazard metrics are proposed based on two EPs to evaluate hazardous levels caused by different types of noise. Moreover Gaussian noise and single-tone noise are simulated to evaluate performances of the proposed EPs and the noise metrics. The results show that both EPs can reflect the responses of the BM to different types of noise. For Gaussian noise there is a frequency shift between the velocity EP and the loudness EP. The results suggest that both EPs can be used for assessment of NIHL.
Źródło:
Archives of Acoustics; 2018, 43, 3; 477-486
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nuisance assessment of different annoying sounds based on psychoacoustic metrics and electroencephalography
Ocena uciążliwości wybranych źródeł hałasu na podstawie parametrów psychoakustycznych i badań elektroencefalograficznych
Autorzy:
Pamuła, H.
Kasprzak, C.
Kłaczyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/328109.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
noise assessment
annoying sounds
sound nuisance
sound quality
EEG
psychoacoustics
ocena hałasu
dźwięk uciążliwy
uciążliwość hałasu
jakość dźwięku
psychoakustyka
Opis:
The aim of the study was to assess whether four psychoacoustic parameters (sharpness, roughness, fluctuation strength and tonality) are useful in describing the perceived annoyance of selected noise sources with respect to an objective assessment based on the acoustics standards. Second goal was to verify if the perceived annoyance of such noises correlates with dominant frequency in electroencephalography (EEG) frequency bands. Twenty sound sources, varying in the degree of nuisance, have been assessed by 178 respondents in an Internet-based psychoacoustic test. Obtained annoyance grades were correlated with calculated psychoacoustic and normative parameters and the positive correlation between perceived annoyance and three psychoacoustic parameters (sharpness, roughness and fluctuation strength) was found. In the second part EEG study during listening of recorded sounds was performed on 18 healthy volunteers. Spearman’s rank correlation confirmed that dominant frequencies in alpha (7-14 Hz) and beta2 band (20-30 Hz) were rising with the increasing annoyance of the sounds. Results obtained may be useful in specifying and clarifying permissible noise levels for annoying sounds.
Celem prac było zbadanie czy psychoakustyczne parametry takie jak ostrość, szorstkość, siła fluktuacji, tonalność mogą być użyteczne do opisu uciążliwości wybranych źródeł hałasu, w odniesieniu do obiektywnej oceny opartej o akustyczne standardy. Drugim celem pracy było sprawdzenie, czy postrzegana uciążliwość tych dźwięków koreluje z częstotliwościami dominującymi w pasmach częstotliwości stosowanych w elektroencefalografii (EEG). W pierwszej części badań 178 osób wypełniło ankietę, oceniając uciążliwość prezentowanych dźwięków. Otrzymane oceny zostały skorelowane z wyliczonymi psychoakustycznymi i normatywnymi parametrami. Potwierdzono, że wraz ze wzrostem wartości parametrów takich jak ostrość, szorstkość i siła fluktuacji, wzrasta także postrzegana przez słuchaczy uciążliwość dźwięków. W drugiej części eksperymentu wykonano badania EEG 18 osób podczas odsłuchu powyższych 20 nagrań. Test korelacji rang Spearmana potwierdził, że dominujące częstotliwości w paśmie alfa (7-14Hz) i beta2 (20-30Hz) wzrastały wraz ze wzrostem średniej oceny uciążliwości. Wyniki przeprowadzonych badań mogą być przydatne do doprecyzowania parametrów oceny hałasu i ich dopuszczalnych wartości.
Źródło:
Diagnostyka; 2016, 17, 3; 67-74
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies