Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "model wastewater" wg kryterium: Wszystkie pola


Tytuł:
Electrocoagulation of model wastewater using aluminum electrodes
Autorzy:
Smoczyński, L.
Muńska, K. T.
Pierożyński, B.
Kosobucka, M.
Powiązania:
https://bibliotekanauki.pl/articles/779115.pdf
Data publikacji:
2012
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
model wastewater
dose of aluminum electrocoagulant
Opis:
Electrocoagulation makes an alternative method to chemical coagulation. This paper presents the results obtained during the electrocoagulation of the model wastewater using aluminum electrodes. The wastewater was treated by means of chronopotentiometric electrocoagulation process in a static system, at the constant current I = 0.3 A; therefore higher doses of electrocoagulant required longer electrocoagulation time. Changes in zeta potential, pH, turbidity, chemical oxygen demand (COD), suspended solids and total phosphorus concentrations in the treated wastewater were determined. A new method for determining the optimal dosage of the aluminum electrocoagulant was proposed through application of the third degree polynomial function rather than the parabolic equation. An increase in the electrocoagulant dose raised the share of sweep fl occulation in the studied treatment process, resulting in the effective removal over 90% of phosphorus compounds from the system.
Źródło:
Polish Journal of Chemical Technology; 2012, 14, 3; 66-70
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statyczna elektrokoagulacja ścieków modelowych
Statical electrocoagulation of model wastewater
Autorzy:
Smoczyński, L.
Zaborowska-Piworowicz, A.
Wardzyńska, R.
Załęska-Chróst, B.
Dłużyńska, K.
Powiązania:
https://bibliotekanauki.pl/articles/126390.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
elektrokoagulacja
system statyczny
ścieki modelowe
electrocoagulation
static system
model wastewater
Opis:
Przedstawiono wyniki elektrochemicznego oczyszczania ścieków modelowych. Porównano parametry oraz efekty elektrolitycznego oczyszczania ścieków w warunkach chronopotencjometrycznych (CHRP), tj. przy stałym natężeniu prądu (I = const), oraz chronoamperometrycznych (CHRA), tj. przy stałym napięciu (U = const). Elektrolizę prowadzono w układzie statycznym z użyciem elektrolizera z elektrodami glinowymi. Zastosowano 6-elektrodowy (3 katody i 3 anody) elektrolizer. Po elektrokoagulacji i sedymentacji osadu w roztworze oznaczano chemiczne zapotrzebowanie na tlen ChZT, mętność, barwę, zawiesiny oraz stężenie fosforu ogólnego.
This paper presents the results of electrochemical treatment of model wastewater. Parameters and results of electrolytic treatment of the model wastewater under chronopotentiometric (CHRP) conditions, ie at constant current (I = const), and under chronoamperomtric (CHRA) conditions, ie at constant voltage (U = const), were compared in the study. Electrolysis was performed in a static system, using an electrolyser with aluminium electrodes. Six-electrode (three cathodes and three anodes) electrolyzers were applied. Chemical oxygen demand (COD), color, turbidity, suspended solids and total phosporus concentration were measured after electrocoagulation and sludge sedimentation. The process of static electrocoagulation was found to be an effective method for model wastewater treatment.
Źródło:
Proceedings of ECOpole; 2009, 3, 2; 501-507
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electrocoagulation of Model Wastewater Using Iron Elect
Elektrokoagulacja ścieków modelowych na elektrodach żelaznych
Autorzy:
Smoczyński, L.
Muńska, K. T.
Pierożyński, B.
Kosobucka, M.
Powiązania:
https://bibliotekanauki.pl/articles/388987.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
model wastewater
dose of iron electrocoagulant
ścieki modelowe
dawka elektrokoagulantu żelazowego
Opis:
This paper presents the results of electrocoagulation of model wastewater using iron electrodes under laboratory conditions. The investigated wastewater was susceptible to electrolytic treatment, and the model system supported the performance of analyses in seven replications, generating a database for reliable statistical and mathematical processing. Wastewater was treated by chronopotentiometric electrocoagulation in a static system at constant current intensity I = 0.3 A. Changes in supply voltage for I = const were registered over time. Changes in pH, turbidity, chemical oxygen demand (COD), suspended solids and total phosphorus concentrations in the treated wastewater were determined. A new method for determining the optimal dosage of the iron electrocoagulant was proposed by relying on the third degree polynomial function rather than the parabolic equation. The proposed method, justified theoretically and demonstrated practically, enabled precise determination of the electrocoagulant dose. An increase in the electrocoagulant dose increased the share of sweep electrocoagulation in the wastewater treatment process.
W pracy przedstawiono wyniki badań laboratoryjnych procesu elektrokoagulacji ścieków modelowych na elektrodach żelaznych. Użyte ścieki okazały się podatne na oczyszczanie elektrolityczne i tym samym, jako układ modelowy, umożliwiły prowadzenie badań aż w 7 powtórzeniach, co z kolei zapewniło bazę danych nadającą się do wiarygodnej obróbki statystyczno-matematycznej. Oczyszczanie ścieków prowadzono w statycznych warunkach chronopotencjometrycznych, tj. przy stałym prądzie I = 0,3 A. Każdorazowo rejestrowano zmiany napięcia zasilania w czasie zapewniające I = const. Oznaczano zmiany pH, zawiesin i mętności, ChZT oraz fosforu ogólnego w oczyszczanych ściekach. W odróżnieniu od metody wyznaczania dawki koagulantu z równania odpowiedniej paraboli, dla badanego procesu elektrokoagulacji zaproponowano oryginalną, nową metodę obliczania dawki optymalnej elektrokoagulantu żelazowego z równania wielomianu III stopnia. Metoda ta, uzasadniona teoretycznie i praktycznie, umożliwiała każdorazowo bardzo precyzyjne określenie takiej dawki. Stwierdzono, że wzrost dawki elektrokoagulantu żelazowego w układzie prowadzi do zwiększenia udziału elektrokoagulacji „zamiatającej” w badanym procesie oczyszczania ścieków.
Źródło:
Ecological Chemistry and Engineering. A; 2013, 20, 10; 1143-1152
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektrokoagulacja ścieków modelowych na elektrodach żelaznych
Electrocoagulation of model wastewater using iron electrodes
Autorzy:
Smoczyński, L.
Muńska, K. T.
Pierożyński, B.
Kosobucka, M.
Powiązania:
https://bibliotekanauki.pl/articles/125995.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ścieki modelowe
dawka elektrokoagulantu żelazowego
elektrokoagulant żelazowy
model wastewater
dose of iron electrocoagulant
Opis:
Przedstawiono wyniki badań laboratoryjnych procesu elektrokoagulacji ścieków modelowych na elektrodach żelaznych. Użyte ścieki okazały się podatne na oczyszczanie elektrolityczne i tym samym, jako układ modelowy, umożliwiły prowadzenie badań aż w 7 powtórzeniach, co z kolei zapewniło bazę danych, nadającą się do wiarygodnej obróbki statystyczno-matematycznej. Oczyszczanie ścieków prowadzono w statycznych warunkach chronopotencjometrycznych, tj. przy stałym natężeniu prądu I = 0,3 A. Każdorazowo rejestrowano zmiany napięcia zasilania w czasie, zapewniające I = const. Oznaczano zmiany pH, zawiesin i mętności, ChZT oraz fosforu ogólnego w oczyszczanych ściekach. W odróżnieniu od metody wyznaczania dawki koagulantu z równania odpowiedniej paraboli dla badanego procesu elektrokoagulacji zaproponowano oryginalną, nową metodę obliczania dawki optymalnej elektrokoagulantu żelazowego z równania wielomianu III stopnia. Metoda ta, uzasadniona teoretycznie i praktycznie, umożliwiała każdorazowo bardzo precyzyjne określenie takiej dawki. Stwierdzono, że wzrost dawki elektrokoagulantu żelazowego w układzie prowadzi do zwiększenia udziału elektrokoagulacji „zamiatającej” w badanym procesie oczyszczania ścieków.
This paper presents the results of electrocoagulation of model wastewater using iron electrodes under laboratory conditions. The investigated wastewater was susceptible to electrolytic treatment, and the model system supported the performance of analyses in seven replications, generating a database for reliable statistical and mathematical processing. Wastewater was treated by chronopotentiometric electrocoagulation in a static system at constant current intensity I = 0.3 A. Changes in supply voltage for I=const were registered over time. Changes in pH, turbidity, chemical oxygen demand (COD), suspended solids and total phosphorus concentrations in the treated wastewater were determined. A new method for determining the optimal dosage of the iron electrocoagulant was proposed by relying on the third degree polynomial function rather than the parabolic equation. The proposed method, justified theoretically and demonstrated practically, enabled precise determination of the electrocoagulant dose. An increase in the electrocoagulant dose increased the share of sweep electrocoagulation in the wastewater treatment process.
Źródło:
Proceedings of ECOpole; 2012, 6, 1; 402-408
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Destabilizacja ścieków modelowych w procesie koagulacji chemicznej
Destabilization of model wastewater in the chemical coagulation process
Autorzy:
Smoczyński, L.
Muńska, K. T.
Kosobucka, M.
Pierożyński, B.
Wardzyńska, R.
Załęska-Chróst, B.
Powiązania:
https://bibliotekanauki.pl/articles/127099.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
koagulacja chemiczna
ścieki modelowe
dawka koagulantu
chemical coagulation
model wastewater
coagulant dose
Opis:
W niniejszej pracy przedstawiono, opisano i zinterpretowano wyniki badań laboratoryjnych procesu koagulacji-flokulacji ścieków modelowych. Zastosowane ścieki modelowe okazały się podatne na oczyszczanie metodą koagulacji chemicznej. Zastosowano i porównano dwa komercyjne koagulanty: PAC - wyprodukowany w zakładach chemicznych DEMPOL-ECO oraz PIX - wyprodukowany przez firmę KEMIPOL. Do przedstawienia i analizy uzyskanej bazy danych doświadczalnych z powodzeniem zastosowano model matematyczny w postaci wielomianu drugiego stopnia. Minimum takiej paraboli każdorazowo stanowiła dawka koagulantu precyzyjnie obliczana i traktowana jako dawka optymalna. Zastosowanie wyższej, aniżeli optymalna, dawki koagulantu prowadziło każdorazowo do obniżenia stopnia oczyszczenia koagulowanych ścieków. Szczegółowa analiza wyników usuwania mętności, zawiesin, fosforu ogólnego i zanieczyszczeń określanych w skali ChZT pokazała, że PAC skuteczniej i wydajniej, aniżeli PIX, koagulował badane ścieki modelowe.
This paper discusses the results of laboratory analyses of the coagulation and flocculation of model wastewater. The investigated wastewater was susceptible to treatment by chemical coagulation. The effectiveness of two commercial coagulants, PAC produced at the DEMPOL-ECO Chemical Plant and PIX manufactured by KEMIPOL, was compared. A mathematical model relying on a second-degree polynomial was used to describe and analyze experimental data. In each case, the parabola minimum point was a precisely determined coagulant dose, regarded as the optimal dose. The application of a coagulant dose higher than the optimal dose reduced the effectiveness of wastewater treatment by coagulation. A detailed analysis of turbidity, suspended solids, total phosphorus and pollutant removal measured by the COD test revealed that PAC was a more effective and a more efficient coagulant than PIX.
Źródło:
Proceedings of ECOpole; 2013, 7, 1; 399-404
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetic Model of Wastewater Treatment in Horizontal Flow Flotation Tank
Autorzy:
Antonova, Ekaterina Sergeevna
Sazonov, Dmitry Vasil'evich
Powiązania:
https://bibliotekanauki.pl/articles/123615.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
flotation
mathematical model
wastewater treatment
horizontal flotation tank
Opis:
The flotation wastewater treatment was considered in the paper. The main stages and parameters of flotation process were pointed out. The multistage flotation model considering all main stages of flotation process is presented. However, its main disadvantage is that for the definition of constant characterizing the bubble-particle aggregate formation, the constant value of superficial gas velocity was used, which is incorrect for horizontal flow flotation tank. The modified multistage flotation model with superficial gas velocity as the function of time was proposed. The experiments were carried out on a laboratory setup with a pneumohydraulic system of aeration in order to verify the proposed model. The comparison of experimental and theoretical results proved the importance of superficial gas velocity change consideration.
Źródło:
Journal of Ecological Engineering; 2019, 20, 11; 190-196
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chronopotentiometric and chronoamperometric electrocoagulation of wastewater in a static system
Statyczna elektrokoagulacja ścieków modelowych
Autorzy:
Smoczyński, L.
Zaborowska-Piworowicz, A.A.
Wardzyńska, R.
Załęska-Chróst, B.
Dłużyńska, K.T.
Powiązania:
https://bibliotekanauki.pl/articles/388537.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
elektrokoagulacja
system statyczny
ścieki modelowe
electrocoagulation
chronopotentiometr
chronoamperometr
static system
model wastewater
Opis:
This study presents the results of electrochemical treatment of model wastewater. It compares the parameters and the results of wastewater electrolysis performed by chronopotentiometric electrocoagulation (CHRP) at constant current intensity (I = const) and chronoamperometric electrocoagulation (CHRA) at constant voltage (U = const). Electrolysis was carried out in a static system with the use of an electrolyzer with aluminum electrodes. A six-electrode electrolyzer (three cathodes and three anodes) was applied. The chemical oxygen demand (COD), turbidity, color intensity, suspended solids and total phosphorus concentration of the solution were determined after electrocoagulation and sludge sedimentation.
Przedstawiono wyniki elektrochemicznego oczyszczania ścieków modelowych. Porównano parametry oraz efekty elektrolitycznego oczyszczania ścieków w warunkach chronopotencjometrycznych (CHRP), tj. przy stałym natężeniu prądu (I = const) oraz chronoamperometrycznych (CHRA), tj. przy stałym napięciu (U = const). Elektrolizę prowadzono w układzie statycznym z użyciem elektrolizera z elektrodami glinowymi. Zastosowano 6-eIektrodowy (3 katody i 3 anody) elektrolizer. Po elektrokoagulacji i sedymentacji osadu w roztworze oznaczano chemiczne zapotrzebowanie na tlen ChZT, mętność, barwę, zawiesiny oraz stężenie fosforu ogólnego.
Źródło:
Ecological Chemistry and Engineering. A; 2009, 16, 3; 231-238
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba zwiększenia skuteczności usuwania fosforu w modelu oczyszczalni ścieków
Experiment of increasing effectiveness of phosphorus removal in a model of wastewater treatment plant
Autorzy:
Jóźwiakowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/286701.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
fosfor
oczyszczanie ścieków
opoka
badanie modelowe
phosphorus
wastewater treatment
model studies
Opis:
W pracy przedstawiono wstępne wyniki badań, dotyczące niekonwencjonalnego sposobu usuwania fosforu, przy wykorzystaniu skały wapiennej - opoki, wcześniej poddanej dekarbonizacji w temperaturze 900°C. Badania prowadzono w okresie 6 tygodni na modelowej oczyszczalni ścieków ze złożem piaskowym bez opoki i z opoką. Podczas badań analizowano stężenie fosforu w ściekach dopływających i odpływających z oczyszczalni. Wyniki badań wykazały, że opoka bardzo dobrze sorbuje fosfor ze ścieków bytowych. Średnia skuteczność usuwania fosforu ogólnego w modelowej oczyszczalni ścieków z opoką (90,9%) była ponad dwukrotnie większa, niż w tej samej oczyszczalni bez opoki (42,4%). Szersze zastosowanie tej skały, do usuwania fosforu, wymaga jednak prowadzenia dalszych, szczegółowych badań, które powinny mieć m.in. na celu określenie długości czasu sorpcji fosforu przez opokę.
The paper presents preliminary results of the study on an alternative method of phosphorus removal by using limestone which was first decarbonized at 900°C. The 6-week research was conducted in a model sewage treatment plant with a sandy bed with and without the application of calcareous rock. Phosphorus concentration in sewage influents and effluents was analized. The results suggest that limestone is a very good sorbing agent in relation to phosphorus occurring in domestic sewage. The model sewage treatment plant was on average twice as efficient (90.9%) when calcareous rock was used as it was without the application of the rock (42.4%). However, the use of this rock in phosphorus removal on a large scale requires further, more detailed research which, among other things, should determine the duration of phosphorus sorption by calcareous rock.
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 5(80), 5(80); 249-256
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model biodegradacji zanieczyszczeń w kanalizacji grawitacyjnej uwzględniający wymianę biomasy pomiędzy błoną biologiczną a ściekami
Model of wastewater biodegradation in gravitational sewer concerning biomass exchange between biofilm and sewage
Autorzy:
Łagód, G.
Krukowski, I.
Widomski, M.
Suchorab, Z.
Powiązania:
https://bibliotekanauki.pl/articles/126212.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
kanalizacja grawitacyjna
modelowanie biodegradacji ścieków
jakość ścieków
osad czynny
błona biologiczna
gravity sewerage
modeling of sewage biodegradation
wastewater quality
activated sewage sludge
biofilm
Opis:
Cytowane w literaturze przedmiotu modele biodegradacji ścieków w kanalizacji w warunkach tlenowych najczęściej uwzględniają tylko biomasę zawieszoną w ściekach. Sytuacja tego typu ma miejsce w nowych kolektorach, świeżo oddanych do użytku oraz w przypadkach katastrofalnych dla błony biologicznej - na przykład po całkowitym wymyciu biofilmu lub po jego kontakcie ze ściekami zawierającymi substancje trujące dla biomasy. Jak wynika z badań obiektów rzeczywistych, ważnym czynnikiem w rozważanym procesie jest błona biologiczna. W niektórych przypadkach jej udział w biodegradacji ścieków może być większy niż biomasy zawieszonej. Dzieje się tak podczas przepływów z niewielkimi naprężeniami ścinającymi i przy małej wysokości napełnienia przewodu kanalizacyjnego. Rozbudowa modelu lokalnego o procesy zachodzące w błonie biologicznej pozwala uzyskać porównywalną jakość wyników jak w modelu bez jej uwzględnienia przy możliwym jednoczesnym zmniejszeniu ilości rozważanych frakcji hydrolizujących - z trzech do dwóch. Dodatkowym elementem uwzględnionym w modelu jest również temperatura, ważna ze względu na fakt, iż wpływa na aktywność enzymatyczną mikroorganizmów.
The models of aerobic sewage biodegradation inside the sanitation system, cited in the literature reports, usually concern only the suspended biomass. This situation occurs in newly built conduits, just put into service and after dangerous events for biofilm - eg biofilm removal by flushing wastewater or its contact with sewage containing poisonous substances. The studies conducted at real objects show that biofilm is an important factor in the considered process. In some cases, its participation in sewage biodegradation may be higher than the contribution of a suspended biomass. This situation may be observed during the sewage flow at low shear stress and low height of sanitation pipe filling. The extension of local model covering the biofilm processes enables to obtain the comparable quality of results as in the case of the model not covering these processes but allowing to reduce the number of hydrolyzing fractions, from three to two. The sewage temperature, important because it influences the enzymatic activity of microorganisms is the additional element considered in this model.
Źródło:
Proceedings of ECOpole; 2010, 4, 1; 153-159
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear stabilizing control of an uncertain bioprocess model
Autorzy:
Dimitrova, N.
Krastanov, M.
Powiązania:
https://bibliotekanauki.pl/articles/930090.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
stabilność asymptotyczna
sterowanie nieliniowe
wastewater treatment model
local bifurcations of steady states
asymptotic stabilization
extremum seeking
uncertain data
Opis:
In this paper we consider a nonlinear model of a biological wastewater treatment process, based on two microbial populations and two substrates. The model, described by a four-dimensional dynamic system, is known to be practically verified and reliable. First we study the equilibrium points of the open-loop system, their stability and local bifurcations with respect to the control variable. Further we propose a feedback control law for asymptotic stabilization of the closed-loop system towards a previously chosen operating point. A numerical extremum seeking algorithm is designed to stabilize the dynamics towards the maximum methane output flow rate in the presence of coefficient uncertainties. Computer simulations in Maple are reported to illustrate the theoretical results.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2009, 19, 3; 441-454
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies