Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "microwave plasma" wg kryterium: Wszystkie pola


Wyświetlanie 1-17 z 17
Tytuł:
Microwave plasma for hydrogen production from liquids
Autorzy:
Czylkowski, D.
Hrycak, B.
Miotk, R.
Jasiński, M.
Mizeraczyk, J.
Dors, M.
Powiązania:
https://bibliotekanauki.pl/articles/148564.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dry reforming
ethanol
hydrogen production
isopropanol
kerosene
microwave plasma
Opis:
The hydrogen production by conversion of liquid compounds containing hydrogen was investigated experimentally. The waveguide-supplied metal cylinder-based microwave plasma source (MPS) operated at frequency of 915 MHz at atmospheric pressure was used. The decomposition of ethanol, isopropanol and kerosene was performed employing plasma dry reforming process. The liquid was introduced into the plasma in the form of vapour. The amount of vapour ranged from 0.4 to 2.4 kg/h. Carbon dioxide with the fl ow rate ranged from 1200 to 2700 NL/h was used as a working gas. The absorbed microwave power was up to 6 kW. The effect of absorbed microwave power, liquid composition, liquid fl ow rate and working gas fl ow rate was analysed. All these parameters have a clear infl uence on the hydrogen production effi ciency, which was described with such parameters as the hydrogen production rate [NL(H2)/h] and the energy yield of hydrogen production [NL(H2)/kWh]. The best achieved experimental results showed that the hydrogen production rate was up to 1116 NL(H2)/h and the energy yield was 223 NL(H2) per kWh of absorbed microwave energy. The results were obtained in the case of isopropanol dry reforming. The presented catalyst-free microwave plasma method can be adapted for hydrogen production not only from ethanol, isopropanol and kerosene, but also from different other liquid compounds containing hydrogen, like gasoline, heavy oils and biofuels.
Źródło:
Nukleonika; 2016, 61, 2; 185-190
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Decomposition of tars in microwave plasma – preliminary results
Autorzy:
Wnukowski, M
Powiązania:
https://bibliotekanauki.pl/articles/125310.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
tar
gasification
microwave plasma
Opis:
The paper refers to the main problem connected with biomass gasification - a presence of tar in a product gas. This paper presents preliminary results of tar decomposition in a microwave plasma reactor. It gives a basic insight into the construction and work of the plasma reactor. During the experiment, researches were carried out on toluene as a tar surrogate. As a carrier gas for toluene and as a plasma agent, nitrogen was used. Flow rates of the gases and the microwave generator’s power were constant during the whole experiment. Results of the experiment showed that the decomposition process of toluene was effective because the decomposition efficiency attained above 95%. The main products of tar decomposition were light hydrocarbons and soot. The article also gives plans for further research in a matter of tar removal from the product gas.
Źródło:
Journal of Ecological Engineering; 2014, 15, 3; 23-28
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical Analysis of Metal-Cylinder-Based Microwave Plasma Module
Autorzy:
Sobański, M.
Jasiński, M.
Mizeraczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/1366115.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
88.80.hp
84.40.-x
52.35.Hr
84.40.Dc
02.70.Dh
88.30.E-
52.65.-y
52.50.Dg
11.55.-m
52.40.Fd
84.40.Az
Opis:
We present optimization of energy transfer in the waveguide-supplied metal-cylinder-based microwave plasma module with an inner cylindrical quartz tube. The construction of microwave plasma module is based on a WR 340 waveguide standard. Presented microwave plasma module operates at atmospheric pressure and frequency of 2.45 GHz. There is a reduced height section waveguide in microwave plasma module which provides local increase of the electric field in the plasma region. Microwave plasma module is terminated with a movable plunger which plays the role of the tuning element. Tuning characteristics of microwave plasma module are defined as the dependence of the $P_{R}$/$P_{I}$ on the position $l_{s}$ of the movable plunger, where $P_{R}$ and $P_{I}$ are the microwave power reflected and power incident, respectively. The powers $P_{R}$ and $P_{I}$ are measured in the input plane of microwave plasma module. The purpose of the presented optimization is to achieve $P_{R}$ lower than 5% of $P_{I}$ in widest range of position of movable plunger $l_{s}$. We used Comsol Multiphysics software to make numerical analysis which allows to optimize the parameters of microwave plasma module. Results of numerical analysis show that $P_{R}$/$P_{I}$ is lower than 0.05 in a wide range of movable plunger position $l_{s}$.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1309-1311
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrofalowy moduł plazmowy do produkcji wodoru
Microwave plasma module for hydrogen production
Autorzy:
Sobański, M.
Jasiński, M.
Mizeraczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/158955.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
mikrofalowy moduł plazmowy
mikrofalowy generator plazmy
wyładowanie mikrofalowe
wyładowanie atmosferyczne
produkcja wodoru
microwave plasma module
microwave plasma source
microwave discharges
atmospheric discharges
hydrogen production
Opis:
Mikrofalowy moduł plazmowy (MMP) służy do produkcji wodoru poprzez reforming węglowodorów. W pracy przedstawiono wyniki optymalizacji transferu energii w MMP o strukturze współosiowej zasilanym falowodem WR 340. W omawianym MMP wyładowanie mikrofalowe powstaje pod ciśnieniem atmosferycznym, a częstotliwość pracy wynosi 2,45 GHz. Omawiany moduł mikrofalowy jest wyposażony w ruchomy zwierak falowodowy, który stanowi element strojący. Optymalizacja prezentowanego MMP polega na obliczeniu wymiarów elementów konstrukcyjnych, które zapewnią minimalny stosunek mocy fali odbitej do mocy fali padającej w płaszczyźnie wejściowej w możliwie najszerszym zakresie zmian położenia zwieraka falowodowego ls. Optymalizacja została przeprowadzona numerycznie za pomocą programu Comsol Multiphysics. Główne elementy konstrukcyjne, które podlegały optymalizacji to długość zwartego odcinka linii współosiowej, średnica wewnętrznego przewodu linii współosiowej oraz wysokość falowodu o obniżonej wysokości. Oprócz sprawności energetycznej pożądane jest, aby kształt charakterystyki strojenia nie zależał od parametrów plazmy, które z kolei zależą od takich czynników jak moc mikrofal absorbowanych, skład i natężenie przepływu gazu roboczego.
Microwave plasma module (MPM) is used for hydrogen production via conversion of hydrocarbons. We present optimization of energy transfer in the waveguide-supplied coaxial-linebased MPM. The MPM operates at atmospheric pressure and frequency of 2.45 GHz. The MPM is terminated with movable plunger which plays the role of the tuning element. Tuning characteristics are defined as the dependence of the PR/PI,i. e. the fraction of the incident microwave power reflected at the MPM input as a function of the position ls of the movable plunger, where PR and PI are power reflected and power incident, respectively. The powers PR and PI are measured in input plane of the MPM. The main purpose of the optimization is to calculate dimensions of some construction elements which ensure the lowest level of PR/PI in widest range of normalized to wavelength movable plunger position (ls/λg). Optimization has been performed using Comsol Multiphysics software. The main construction elements which have been optimized are the length of the shorted coaxial line section, the diameter of the inner conductor of coaxial line and finally the height of the reduced height waveguide section. It is also desired that the shape of the tuning characteristics should be independent of plasma parameters which depend on working gas type, working gas flow rate and power absorbed.
Źródło:
Prace Instytutu Elektrotechniki; 2012, 259; 93-94
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Post-Synthesis Microwave Plasma Treatment Effect on Magnetization and Morphology of Manganese-Iron Oxide Nanoparticles
Autorzy:
Busharat, Muhammad Aqib
Naz, Muhammad Yasin
Shukrullah, Shazia
Zahid, Muhammad
Powiązania:
https://bibliotekanauki.pl/articles/2125527.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ferrite nanoparticles
microwave discharge
sol-gel synthesis
magnetic properties
Opis:
The influence of microwave (MW) plasma on magnetization and morphology of sol-gel synthesized MnFe2O4 ferrite nanoparticles is investigated in this study. Manganese (II) nitrate hexahydrate, ferric (III) nitrate nanohydrate and citric acid were used to synthesize ferrite nanoparticles via a facile sol-gel route. These ferrite nanostructures were heat-treated at 700ºC and then given MW plasma treatment for 10 min. The pristine MnFe2O4 and plasma treated MnFe2O4 showed almost similar structural formation with a slight increase in crystallinity on plasma treatment. However, XRD peak intensity slightly increased after plasma treatment, reflecting better crystallinity of the nanostructures. The size of the particle increased from 35 nm to 39 nm on plasma treatment. It was challenging to deduce the surface morphology of the nanoparticles since both samples were composed of a mixture of big and small clusters. Clusters that had been treated with plasma were larger in size than pristine ones. The band gap energy of the pristine MnFe2O4 sample was about 5.92 eV, which increased to 6.01 eV after treatment with MW plasma. The saturation magnetization of MnFe2O4 sample was noted about 0.78 emu/g before plasma treatment and 0.68 emu/g after MW plasma treatment.
Źródło:
Archives of Metallurgy and Materials; 2022, 67, 3; 837--842
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza numeryczna mikrofalowego modułu plazmowego do produkcji wodoru
Numerical analysis of microwave plasma module for hydrogen production
Autorzy:
Sobański, M.
Jasiński, M.
Mizeraczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/159714.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
mikrofalowy moduł plazmowy
mikrofalowy generator plazmy
wyładowanie mikrofalowe
produkcja wodoru
microwave plasma module
microwave plasma source
microwave discharges
hydrogen production
Opis:
Mikrofalowy moduł plazmowy (MMP) służy do produkcji wodoru poprzez reforming węglowodorów. W pracy przedstawiono wyniki optymalizacji transferu energii w MMP o strukturze współosiowej zasilanym falowodem WR 340. W omawianym MMP wyładowanie mikrofalowe powstaje pod ciśnieniem atmosferycznym, a częstotliwość pracy wynosi 2,45 GHz. Wyniki analizy numerycznej pokazują, że dla wybranej konfiguracji MMP minimalny stosunek mocy fali odbitej do mocy fali padającej osiąga wartości po-niżej 5% w szerokim zakresie zmian położenia elementu strojącego.
Microwave plasma module (MPM) is used for hydrogen production via conversion of hydrocarbons. We present optimization of energy transfer in the waveguide-supplied coaxial-line-based MPM. The MPM operates at atmospheric pressure and frequency of 2.45 GHz. The MPM is terminated with movable plunger which plays the role of the tuning element. Tuning characteristics are defined as the dependence of the PR / PI as a function of the position ls of the movable plunger, where PR and PI are power reflected and power incident, respectively. The powers PR and PI are measured in input plane of the MPM. Optimization has been performed using Comsol Multiphysics software. The main construction elements which have been optimized are the length of the shorted coaxial line section, the diameter of the inner conductor of coaxial line and finally the height of the reduced height waveguide section.
Źródło:
Prace Instytutu Elektrotechniki; 2013, 261; 105-114
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A microwave plasma potential in producer gas cleaning — preliminary results with a gas derived from a sewage sludge
Autorzy:
Kordylewski, W.
Michalski, J.
Ociepa, M.
Wnukowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/175493.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sewage sludge
gasification
tar
microwave plasma
Opis:
The paper presents an attempt to evaluate the impact of coal and coal mine methane cocombustion on the physics of the heat exchange in an 140 t/h pulverized-coal boiler through an analysis of 21 combinations of the boiler operating parameters – three different boiler loads (50, 75, and 100%) and seven values of the fired gas thermal contribution (0–60%). The obtained results are the temperature distribution of flue gas and steam in the boiler characteristic points, the heat transfer coefficient values for the boiler individual elements expressing the nature of changes in the heat transfer and the change in the boiler efficiency depending on how much gas is actually fired. An increase in the amount of co-fired gas involves a temperature increase along the flue gas path. This is the effect of the reduction in the amount of heat collected by the evaporator in the furnace. For these reason, the flue gas temperature at the furnace outlet rises by 9 K on average per a 0.1 increment in the fired gas thermal contribution. The temperature rise improves the heat transfer in the boiler heat exchangers – for the first- and the secondstage superheater the improvement totals 2.8% at a 10 pp. increase in the fired gas thermal contribution. However, the rise in the flue gas temperature at the boiler outlet involves a drop in the boiler efficiency (by 0.13 pp. for a rise in the fired gas thermal contribution by 0.1).
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2017, 137; 19-39
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of low temperature inactivation of spores using microwave excited air plasma
Autorzy:
Nagatsu, M.
Singh, M. K.
Zhao, Y.
Fujioka, Y.
Ogino, A.
Powiązania:
https://bibliotekanauki.pl/articles/385185.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
plasma sterilization
low temperature plasma
microwave plasma
air plasma
VUV
radicals
Opis:
In the present study, we investigated the inactivation characteristics and contribution of different inactivating factors generated in a low temperature and low pressure nitrogen, oxygen and air-simulated plasma for the inactivation of Geobacillus stearothermophilus spores. We used three optical filters i.e. thin quartz (lambda>180 nm), lithium fluorine (LiF, lambda>120 nm) and Pyrex glass (lambda>300 nm) plates to identify the most efficient wavelength range. The effect of optical radiations alone was studied through placing a small isolated and evacuated chamber with spore sample inside the plasma chamber.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 108-111
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie smół z gazu ze zgazowania osadu ściekowego z zastosowaniem plazmy mikrofalowej
TAR REMOVAL FROM GAS IN SEWAGE SLUDGE GASIFICATION PROCESS APPLYING MICROWAVE PLASMA
Autorzy:
KORDYLEWSKI, Włodzimierz
MICHALSKI, Józef
OCIEPA, Mirosław
WNUKOWSKI, Mateusz
Powiązania:
https://bibliotekanauki.pl/chapters/1965642.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Opis:
W pracy przedstawiono problem zanieczyszczenia gazu procesowego ze zgazowanie osadów ściekowych smołami, charakteryzując zagrożenia powodowane nim i wskazując metody ograniczenia udziału smół w gazie. W części badawczej praca poświęcona jest zagadnieniu usuwania węglowodorów pierścieniowych z gazu procesowego z zastosowaniem plazmy mikrofalowej. Przedstawiono zasadę działania mikrofalowych generatorów plazmy i mechanizmy jej oddziaływania na prekursory smół. Badania zrealizowano w skali laboratoryjnej. Główne składniki stanowiska badawczego stanowiły: wsadowy reaktor zgazowujący o wydajności ok. 1,5 m3/h gazu procesowego oraz mikrofalowy reaktor plazmowy zasilany przez magnetron o mocy 2 kW. Materiałem wsadowym do reaktora był suszony osad ściekowy. Oznaczano skład gazu procesowego za reaktorem plazmowym przed zasilaniem reaktora mikrofalami i po działaniu plazmy mikrofalowej. W wyniku oddziaływania plazmy mikrofalowej na gaz procesowy obserwowano znaczny ubytek węglowodorów oraz wzrost stężenia CO i H2. Do identyfikacji składników w gazie procesowym użyto techniki pomiarowej NDIR i GC. Efektywność usuwania prekursorów smół była w zakresie 80–90%, zależnie od czasu przebywania w strefie plazmy.
The problem of the gas contamination with tar in the process of sewage sludge gasification has been presented in the paper. Threats caused by tar were characterized and it was pointed out ways to reduce tar content in the gas. The paper’s research part is focused on removing aromatic hydrocarbons from the process gas using microwave plasma. It presents the principle of operation of microwave plasma generators and mechanisms of plasma’s influence on precursors for tar. The research were carried out on a laboratory scale. The main components of the laboratory apparatus were: a bed type gasification reactor with an output of the process gas being approx. 1.5 m3 /h and the microwave plasma reactor powered by a magnetron 2 kW. Batch material to the reactor was dried sewage sludge in these studies. The composition of the process gas was estimated in two cases: with and without plasma conditioning. As a result of microwave plasma impact on the process gas a significant loss of hydrocarbons and an increase in the concentration of CO and H2 was observed. For the identification of process gas components a NDIR measurement technique and GC were used. The conversion efficiency of tar precursors was in the range of 80-90%, depending on the residence time in the plasma zone.
Źródło:
Powietrze atmosferyczne. Jakość – zagrożenia – ochrona; 154-163
9788374939423
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bezpieczeństwo pracy z mikrofalami przy urządzeniach do wytwarzania plazmy
Safety rules during work with microwave generated plasma
Autorzy:
Araszkiewicz, M.
Kordylewski, W.
Wnukowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/179006.pdf
Data publikacji:
2016
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
mikrofale
generacja plazmy
promieniowanie mikrofalowe
promieniowanie elektromagnetyczne
strefy bezpieczeństwa
microwaves
plasma generation
microwave radiation
electromagnetic radiation
Opis:
W artykule przedstawiono sposób zapewnienia bezpieczeństwa podczas prowadzenia procesu plazmowego z wykorzystaniem mikrofal. Omówiono podstawowe elementy aparatury mikrofalowej wspólne dla wszystkich tego rodzaju urządzeń. Przedstawiono również najważniejsze zagrożenia, jakie można spotkać w przypadku stosowania mikrofal w aparaturze przemysłowej. Z uwagi na specyfikę promieniowania mikrofalowego, zasady bezpieczeństwa są w tym przypadku szczególnie istotne. Analiza potencjalnego ryzyka, metody wyznaczania poszczególnych stref bezpieczeństwa, jak i postępowanie w celu uzyskania certyfikacji stanowiska ze źródłem pola elektromagnetycznego o wysokiej częstotliwości zostały szczegółowo opisane. Dodatkowo przytoczono podstawowe akty prawne dotyczące tej tematyki.
The methods of providing the safety of microwave generated plasma conduction processes are presented in the article. Basic elements of microwave apparatuses common for the all microwave devices are discussed. The most important potential dangers that can be spotted around microwave industrial apparatuses are listed. The safety rules are extremely important due to the specific micro-wave behavior. Analysis of potential risk, the method of determination of each safety perimeters and ways of obtaining the safety certifications of the microwave site were precisely described. Additionally the legal framework, both European and Polish, on the topic is present m the article.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2016, 10; 16-19
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Ho3+ ions for quantitation of iron (Fe) in 0.1 M HCl solution using microwave plasma-atomic emission spectrometry (MP-AES)
Wpływ jonów Ho3+ na jakościowe oznaczanie żelaza w roztworze 0.1 M HCI metodą atomowej spektroskopii emisyjnej z plazmą mikrofalową (MP-AES)
Autorzy:
Stępień, M.
Bukowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/264243.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
MP-AES
ANOVA
Fe
Ho3+
Opis:
During research work in the Non-Ferrous Metals Department on AGH University of Science and Technology concerning new corrosion inhibitors for iron alloys in magnetic fields, Ho3+ ions were proposed as one of the new inhibitors. One of the methods for determining the rate of the corrosion process is determining the concentration of Fe ions in a solution. Due to the required high precision of determining the concentration of Fe ions in a solution contains Ho3+ ions with a wide range of concentrations, the influence of the matrix effect and interferences of Ho3+ ions must be known. The present work investigates the impact of Ho ions within a range of 0 to 100 mg/L for the quantitation of Fe ions in a 0.1 M HCl solution using the MP-AES method. The obtained results were analyzed using the single-factor ANOVA method. In a range of up to 40 mg/L, Ho3+ ions are not a significant factor to determining the Fe concentration by MP-AES.
W trakcie prac badawczych prowadzonych na Katedrze Fizykochemii i Metalurgii Metali Nieżelaznych na Akademii Górniczo-Hutniczej w Krakowie dotyczących nowych inhibitorów korozji stopów żelaza w polu magnetycznym, jako jeden z nowych inhibitorów zaproponowano jony Ho. Jedną z metod określenia postępów procesu korozji było oznaczenie stężenia jonów Fe w roztworze metodą atomowej spektroskopii emisyjnej w plazmie mikrofalowej (MP-AES). Z uwagi na wymaganą wysoką precyzję określenia niewielkiej zawartości jonów Fe w roztworach o różnej zawartości jonów Ho konieczne stało się zbadanie, czy obecność jonów Ho wpływa istotnie na ocenę ilościową jonów Fe metodą MP-AES. W niniejszej pracy zbadano wpływ stężenia jonów Ho w zakresie stężeń od 0 do 100 mg/l na oznaczenie zawartości Fe w 0,1 M kwasie solnym. Uzyskane wyniki poddano analizie statystycznej z wykorzystaniem metody ANOVA. W zakresie stężeń jonów Ho w analicie do 40 mg/L nie wykazano istotnego wpływu na oznaczenie żelaza na poziomie ufności 95%.
Źródło:
Metallurgy and Foundry Engineering; 2018, 44, 3; 109-117
1230-2325
2300-8377
Pojawia się w:
Metallurgy and Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical Emission Spectroscopy of Microwave (915 MHz) Plasma in Atmospheric Pressure Nitrogen with Addition of Ethanol Vapour
Autorzy:
Miotk, R.
Jasiński, M.
Mizeraczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/1366270.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
52.50.Sw
52.70.Kz
Opis:
In this paper results of optical emission spectroscopic study of microwave 915 MHz plasma in atmospheric pressure nitrogen with an addition of ethanol vapour are presented. The plasma was generated in waveguide-supplied cylinder-type nozzleless microwave plasma source. The aim of research was to determine the rotational $T_{rot}$ and vibrational $T_{vib}$ temperatures of CN and $C_2$. A method called bubbling was employed to introduce alcohol (ethanol) into the plasma. The $T_{rot}$ and $T_{vib}$ were determined by comparing the measured and simulated spectra. Obtained rotational and vibrational temperatures of CN and $C_2$ were ranged from 4400 to 5400 K and from 2800 to 3400 K, respectively, depending on the location in the plasma and the microwave absorbed power $P_{A}$.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1329-1331
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interfacing Microchip Based Capillary Electrophoresis System with a Microwave Induced Plasma Optical Emission Spectrometer (uCE-MIP-OES)
Technika sprzężona w układzie mikrochip - elektroforeza kapilarna w optycznej spektrometrii emisyjnej plazmy mikrofalowej
Autorzy:
Matusiewicz, H.
Slachciński, M.
Powiązania:
https://bibliotekanauki.pl/articles/388329.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
plazma mikrofalowa
optyczna spektrometria emisyjna
elektroforeza kapilarna
aparatura
technologia chipowa
microwave induced plasma
optical emission spectrometer
capillary electrophoresis
interface
chip technology
Opis:
A microchip based capillary electrophoresis (uCE) system was interfaced with microwave induced plasma optical emission spectrometry (MIP-OES) to provide rapid elemental separation capabilities. This system uses an extremely low flow micro-cross-flow nebulizer sited directly at the liquid exit of the chip. A supplementary flow of buffer solution at the channel exit was used to improve nebulization efficiency. A small evaporation chamber has been incorporated into the interface in order to prevent the losses associated with traditional spray chambers, allowing the entire sample aerosol to enter the plasma. Syringe pumps were used to manipulate the flow rate and flow direction of the sample, buffer, and supplementary buffer solution. Sample volumes of 40 nanolitre can be analyzed, The feasibility of this hyphenated method for elemental separation was demonstrated by the on-line electrophoretic separation of Ba2+ and Mg2+ ions within 35 s using an 8 cm long separation channel etched in a glass base. Resolution of the Ba2+ and Mg2+ peaks was 0.9 using the chip-based uCE-MIP-OES system.
Opisano metodę rozdziału jonów Ba2+ od Mg 2+ za pomocą mikrosystemu elektroforetycznego (uCE) w połączeniu z optyczną spektrometrią emisyjną (OES) plazmy indukowanej mikrofalowo (MIP). Roztwór próbki (ok. 40 nanolitrów) oraz roztwory buforowe wprowadzano do kanału separacyjnego o długości 8 cm za pomocą pomp strzykawkowych. Zaproponowany system umożliwia rozdział badanych jonów w ciągu 35 s oraz efektywne wprowadzenie próbki, w postaci aerozolu, do źródła wzbudzenia za pomocą układu mikrorozpylacz/minikomora mgielna.
Źródło:
Ecological Chemistry and Engineering. A; 2009, 16, 11; 1443-1450
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spectroscopic Study of $CO_2$ Plasma in Microwave Source Designed for Hydrogen Production via Hydrocarbons Decomposition
Autorzy:
Hrycak, B.
Jasiński, M.
Mizeraczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/1366177.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
52.25.Os
52.50.Dg
52.70.Kz
52.80.Pi
Opis:
In this paper, results of spectroscopic study of microwave (2.45 GHz) plasma at atmospheric pressure and high $CO_2$ flow rate are presented. The plasma was generated by waveguide-supplied nozzleless cylindrical type microwave plasma source. Working gas flow rate and microwave absorbed power varied from 50 up to 150 l/min and from 1 up to 5.5 kW, respectively. The emission spectra in the range of 300-600 nm were recorded. The rotational and vibrational temperatures of $C_2$ molecules, as well as the rotational temperature of OH radicals were determined by comparing the measured and simulated spectra. The plasma gas temperature inferred from rotational temperature of heavy species ranged from 4000 to 6000 K. It depended on location in plasma, microwave absorbed power and working gas flow rate. The presented microwave plasma source can be used in various gas processing applications.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1326-1328
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies of atmospheric - pressure microwave plasmas used for gas processing
Autorzy:
Mizeraczyk, J.
Jasiński, M.
Nowakowska, H.
Dors, M.
Powiązania:
https://bibliotekanauki.pl/articles/146394.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
microwaves
plasma
volatile organic compounds
hydrogen
Opis:
This paper concerns the atmospheric-pressure microwave plasmas and their applications, mainly for gas processing. Several types of atmospheric-pressure microwave sources (MPSs), i.e. surface-wave-sustained MPS, nozzle-type MPSs, nozzleless MPSs, plasma-sheet MPSs and microwave microplasma sources - MmPSs (antenna- and coaxial-line- -based) as well as their performance are presented. The presented experimental results on the optimization of selected MPSs are confronted with results of the modelling of the electromagnetic field in them. The paper deals also with the applications of MPSs for the processing of gases. Two types of the plasma gas processing were experimentally tested: decomposition of volatile organic compounds (VOCs) and reforming of VOCs (mainly methane) into hydrogen. Results of the laboratory experiments on the plasma processing of several highly-concentrated (up to 100%) VOCs, including freon-type refrigerants, in the waveguide-supplied MPSs showed that the microwave discharge plasma is capable of fully decomposing the VOCs at relatively low energy cost. The use of waveguide-supplied coaxial-line-based and metal-cylinder-based nozzleless MPSs to methane reforming into hydrogen turned out to be energetically efficient. These selected results show MPSs to be an attractive tool for gas processing, including the harmful gas decomposition and production of useful gases.
Źródło:
Nukleonika; 2012, 57, 2; 241-247
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using microwave refraction to determine local inhomogeneities of a rotating plasma
Autorzy:
Martseniuk, Yurii P.
Siusko, Yevhen V.
Kovtun, Yurii V.
Powiązania:
https://bibliotekanauki.pl/articles/2202564.pdf
Data publikacji:
2023
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
horn antenna
inhomogeneities
reflected microwave
reflectometry
refraction
Opis:
To determine the local inhomogeneities of a rotating plasma, the method based on microwave refraction was used. The method is based on spectral and correlation analysis of the refl ected signals from the rotating plasma layer at normal and inclined microwave incidence. This method allowed us to determine local inhomogeneities of plasma electron density, angles of azimuthal displacement of grooves, and its angular frequency of rotation. Using an additional 4th horn antenna, in contrast to previous works, it was possible to fi nd and analyze two regions with azimuthal inhomogeneities in the rotating plasma. Analysis of the refl ected signals shows the presence of four grooves, and the angular frequency of rotation = 1.16 × 104 rad/s was also determined.
Źródło:
Nukleonika; 2023, 68, 1; 19--24
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of phosphorus content in marine sediment samples using inductively coupled plasma-optical emission spectrometry (ICP-OES) technique after microwave-assisted aqua regia digestion
Oznaczanie zawartości fosforu w próbkach osadu morskiego z wykorzystaniem techniki optycznej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) po rozkładzie za pomocą wody królewskiej wspomaganym promieniowaniem mikrofalowym
Autorzy:
Szczepańska, K.
Dembska, G.
Zegarowski, Ł.
Pazikowska-Sapota, G.
Galer-Tatarowicz, K.
Aftanas, B.
Powiązania:
https://bibliotekanauki.pl/articles/111550.pdf
Data publikacji:
2017
Wydawca:
Instytut Morski w Gdańsku
Tematy:
phosphorus
marine sediment
inductively coupled plasma optical emission spectrometry
microwave-assisted digestion
fosfor
osad morski
optyczna spektrometria emisyjna ze wzbudzeniem w plazmie indukcyjnie sprzężonej
rozkład wspomagany promieniowaniem mikrofalowym
Opis:
A method for the determination of phosphorus content in marine sediment samples using ICP-OES technique has been developed. A microwave-assisted digestion with aqua regia has been applied for sediment sample dissolution. The method was optimized then its validation parameters were calculated. Assessing the selectivity found the spectral interferences from other elements (especially copper) can be partially eliminated by using the optimal operating conditions. The method exhibited excellent linearity (r>0.999) in the entire measurement range (25-5000 mg P kg-1). It was also characterized by high repeatability (coefficient of variation of 1%) and very good recovery (98%). The low expanded uncertainty (<10%) was associated with a high concentration of phosphorus in the marine sediment samples examined.
Opracowano metodę oznaczania zawartości fosforu w próbkach osadu morskiego z wykorzystaniem techniki ICP-OES. Do roztworzenia próbek osadów zastosowano rozkład za pomocą wody królewskiej wspomagany promieniowaniem mikrofalowym. Metodę zoptymalizowano, a następnie wyznaczono jej parametry walidacyjne. Oceniając selektywność stwierdzono, że interferencje spektralne ze strony innych pierwiastków (szczególnie miedź) mogą być korygowane przez zastosowanie optymalnych warunków pomiaru. Metoda wykazała doskonałą liniowość (r>0.999) w całym zakresie pomiarowym (25-5000 mg P kg-1). Ponadto charakteryzowała się wysoką powtarzalnością (współczynnik zmienności 1%) oraz bardzo dobrym odzyskiem (98%). Niska niepewność rozszerzona (<10%) była związana z wysoką zawartością fosforu w badanych próbkach osadu morskiego.
Źródło:
Biuletyn Instytutu Morskiego w Gdańsku; 2017, 32, 1; 66-71
1230-7424
2450-5536
Pojawia się w:
Biuletyn Instytutu Morskiego w Gdańsku
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-17 z 17

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies