Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "microbiological pollution" wg kryterium: Wszystkie pola


Tytuł:
Microbiological pollution of soils and surface waters of the Pokuttia-Bukovyna Carpathians
Autorzy:
Masikevych, Andrij
Masikevych, Yurij
Malovanyу, Myroslav S.
Blyzniuk, Mykola
Powiązania:
https://bibliotekanauki.pl/articles/2174329.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bacteria
ecosystem
hydrosphere
microbiological pollution
national nature park
soil
Opis:
Based on the analysis of a number of studies, it was found that to assess the state of the environment (including surface waters and soils) it is advisable to use indicators of microbiological pollution, which in general integrally reflect the state of the ecosystem. To assess the dynamics of changes in the pollution of the studied areas, a comparison of monitoring data with the corresponding level of pollution in protected areas (Vyzhnytsia National Nature Park) was used. Research methods included soil and surface water sampling, inoculation on appropriate nutrient selective media, counting of colony forming units (CFU) and other microbiological indicators. To assess the biological activity of soils, urease activity was determined by a method generally accepted in biochemistry. It is established that within the protected areas, despite some existing annual fluctuations, the relative stability of the studied indicators of the hydrosphere is preserved. Studies have shown that soils of anthropogenically altered landscapes are characterised by a high content of sanitary-indicative bacteria. As our research shows, according to the colony forming units (CFU), total microbial count, and titer of Escherichia coli, the soils selected in the protected area of the Vyzhnytsia National Nature Park correspond to the “pure” level. The soils of the territories out of the National Nature Park are characterised by high biological capacity, as evidenced by the level of activity of the enzyme urease and the ratio of the main forms of nitrogen compounds.
Źródło:
Journal of Water and Land Development; 2022, 55; 91--96
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological Risk in Rooms with Mechanical Ventilation
Autorzy:
Lisik, Katarzyna
Cichowicz, Robert
Powiązania:
https://bibliotekanauki.pl/articles/2202136.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
mechanical ventilation
microbiological pollution
dust pollution
air quality
bioaerosol
Opis:
The condition of air quality depends on many external (the amount of pollutant emissions, intensity and type of physico-chemical changes taking place in the atmosphere and large-scale movement of air pollutant masses) as well as internal factors (such as finishing materials, room equipment, heating systems, ventilation systems, and the presence of the humans themselves). As a result, there are various risks related to air quality, including the most important ones related to microbial contamination. For this reason, it was decided to analyze the quality of internal air in terms of microbiological contamination that may occur in university lecture halls with mechanical supply and exhaust ventilation. The analysis also took into account the impact of mechanical ventilation on physical parameters such as temperature, relative humidity as well as the concentration of PM10 and PM2.5 particulate matter pollutants, thus determining the impact of the tested parameters on human health and well-being. All the obtained results were compared with the applicable permissible standards and conclusions were drawn regarding the improvement of the quality of the indoor air microclimate.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 164--171
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nieczystości płynne ze zbiorników bezodpływowych jako źródło zanieczyszczeń mikrobiologicznych wód podziemnych
Liquid waste from septic tanks as a source of microbiological pollution of groundwater
Autorzy:
Nowak, R.
Imperowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/400687.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
kanalizacja bezodpływowa
zanieczyszczenia mikrobiologiczne
jakość wód podziemnych
sewage holding tank system
microbiological pollutions
groundwater quality
Opis:
W Polsce ogromnym problemem jest zanieczyszczenie środowiska gruntowo-wodnego przez nieczystości płynne, pochodzące ze zbiorników bezodpływowych. Dotyczy to szczególnie terenów wiejskich. Negatywne zmiany stwierdzane są zarówno w sąsiedztwie nieszczelnych zbiorników, z których zagęszczone i zagniłe ścieki infiltrują do gruntu, jak i w wodach powierzchniowych i gruntach ornych, do których trafiają nieczystości z opróżnianych zbiorników. W pracy, na przykładzie wybranej gminy, przedstawiono skalę występowania procederu niekontrolowanego odprowadzania ścieków bytowych do środowiska. Zaprezentowane dane porównano z wynikami oceny jakościowej wód podziemnych, ujmowanych w tej samej gminie do celów wodociągowych. W znaczącej części studni woda nie była bezpieczna pod względem sanitarnym, bowiem stwierdzono w niej obecność m.in. zanieczyszczeń mikrobiologicznych. Wśród oznaczonych mikroorganizmów dominowały organizmy wskaźnikowe zanieczyszczenia wód ściekami bytowymi. Problemy z jakością wody zostały odnotowane na ujęciach, zlokalizowanych w pobliżu posesji, wyposażonych w zbiorniki bezodpływowe lub w miejscach, do których w niekontrolowany sposób trafiały ścieki z opróżnianych zbiorników. W ten sposób wykazano, że istnieje związek między niewłaściwie prowadzoną gospodarką ściekową a jakością wód podziemnych, ujmowanych do celów wodociągowych.
Pollution of soil and water environment by liquid waste originating from septic tanks is a huge problem in Poland. This applies especially to rural areas. Negative changes are observed both in the vicinity of the leaking tanks, from which concentrated and rotten sewage infiltrates into the ground, and in surface water as well as arable land, to which impurities from the emptied tanks are discharged. The paper presents the scale of the practice of uncontrolled domestic sewage discharge into the environment on the example of selected municipality. Presented data were compared with the results of the qualitative assessment of groundwater, which is collected in the same municipality for waterworks. In a significant number of wells, water was not safe in sanitary terms, as the presence of microbiological contamination was recorded. Among determined microorganisms, the indicator organisms of domestic waste pollution prevailed. Water quality problems have been reported at intake points located near the properties equipped with septic tanks or in places, to which sewage from emptying septic tanks were transferred in an uncontrolled manner. In this way it has been shown that there is a relationship between improperly maintained wastewater management and groundwater quality collected for the purpose of water supply.
Źródło:
Inżynieria Ekologiczna; 2016, 47; 60-67
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effectiveness of removing microbial pollutants from wastewater by the activated sludge method
Autorzy:
Budzińska, K.
Szejniuk, B.
Jurek, A.
Traczykowski, A.
Michalska, M.
Berleć, K.
Powiązania:
https://bibliotekanauki.pl/articles/208224.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wastewater treatment
water pollution
microbiological pollution
Salmonella
activated sludge
pathogenic microorganisms
Enterobacteriaceae
oczyszczanie ścieków
zanieczyszczenie wody
zanieczyszczenie mikrobiologiczne
osad czynny
mikroorganizmy chorobotwórcze
bakterie jelitowe
Opis:
Wastewater contains numerous saprophytic microorganisms, pathogenic and potentially pathogenic. Detection of bacteria indicating the sanitary state of polluted waters shows the possibility of occurring of pathogenic microorganisms in that environment. In the presented paper, the effectiveness of removing microbiological pollutions from wastewater treated by the activated sludge method has been evaluated, by estimating the elimination of E. coli, faecal streptococci, rods of the genus Salmonella and bacteria of the family Enterobacteriaceae. Experimental research showed that often in spite of a high degree of elimination of bacteria at individual stages of treatment, they are still identified in wastewater discharged to the water environment. The fact of occurring bacteria of the family Enterobacteriaceae and rods of Salmonella in treated wastewater discharged to surface waters is particularly worrying.
Źródło:
Environment Protection Engineering; 2014, 40, 4; 53-67
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrobiologiczne zanieczyszczenie powietrza na terenie oczyszczalni ścieków komunalnych
Microbiological air pollution in the area of municipal sewage treatment plant
Autorzy:
Budzińska, K.
Jurek, A.
Szejniuk, B.
Michalska, M.
Wroński, G.
Powiązania:
https://bibliotekanauki.pl/articles/1819427.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
komunalna oczyszczalnia ścieków
zanieczyszczenie powietrza
zanieczyszczenie mikrobiologiczne
municipal sewage treatment plant
air pollution
microbiological contamination
Opis:
Doświadczenia prowadzone w zasięgu oddziaływania oczyszczalni ścieków wykazały, że skład gatunkowy i ilościowy mikroflory powietrza jest ściśle powiązany z rodzajem i liczbą mikroorganizmów obecnych w ściekach. W skład bioaerozoli w rejonach oczyszczalni ścieków wchodzą bakterie, wirusy oraz liczne gatunki grzybów, w tym mikotoksyczne i alergizujące. Takie aerozole biologiczne sprzyjają odczynom alergicznym, chorobom zakaźnym, a nawet epidemiom i epizootiom. Według doniesień literaturowych [2, 5, 10] czynnikiem umożliwiającym powstawanie bioaerozolu wokół oczyszczalni jest liczba mikroorganizmów obecnych w ściekach. Jako graniczną wartość przyjmuje się zawartość drobnoustrojów na poziomie wyższym od 103 w 1 ml, co warunkuje możliwość uniesienia komórek do powietrza [15]. Do podstawowych parametrów decydujących o zasięgu i stopniu oddziaływania wpływu oczyszczalni ścieków na mikrobiologiczną czystość powietrza należą: wielkość obiektu, stosowana technologia procesów oczyszczania ścieków, sposób przeróbki i postępowania z osadami ściekowymi, staranność eksploatacji obiektów i inne [1, 2]. Drobnoustroje trafiają do powietrza przede wszystkim na skutek realizacji procesów związanych z napowietrzaniem i mieszaniem ścieków oraz rozprowadzaniem ich na urządzeniach biologicznych [11÷13]. W ciągu technologicznym oczyszczalni ścieków można wyróżnić kilka newralgicznych punktów, które w sposób szczególny wpływają na emisję bioaerozoli. Najbardziej negatywny wpływ odnotowano w przypadku urządzeń takich jak kratownia, pompownia wstępna, kanały ścieków surowych, piaskownik, komora napowietrzania i poletka osadowe [5]. Duże ryzyko zdrowotne związane z emisją szkodliwych bioaerozoli powoduje, że konieczne jest prowadzenie kontroli czystości mikrobiologicznej powietrza na terenie i wokół oczyszczalni ścieków. Celem badań było określenie zanieczyszczenia mikrobiologicznego powietrza na terenie mechaniczno-biologicznej oczyszczalni ścieków komunalnych.
The aim of this study was to estimate a degree of microbiological air pollution in the area of a mechanical-biological municipal sewage treatment plant. Four measurement points were situated in the area of the and one research stand was located outside the plant from the windward side (background) - near screen, near sand catchers, at aeration chambers, at sewage sludge deposition site. Air samples were collected in a trail of pollution with the compaction method using the sampler SAS 100. The microbiological analyses involved the quantitative analysis of the following microorganisms: total number of bacteria and fungi, haemolysing staphylococci and , mannitol-positive and mannitol-negative staphylococci, Pseudomonas fluorescens, actinomyces and bac-teria of the Enterobacteriaceae family. Total number of bacteria in particular measurement points varied and ranged from 320 to 4565 cfu in 1 m3 of air. The highest emission of those microorganisms was observed in the vicinity of appliances for mechanical sewage treatment (screen site). The next measurement point where a high number of bacteria was recorded was location in the vicinity of the sewage sludge deposition site. The number of mould fungi occurring in the air at all the measurement points was low and ranged from 420 to 5429 colonies.m-3. The highest concentration of actinomyces in the air was observed in the vicinity of the sewage sludge storage site, where their number ranged from 55 to 450 cfu.m-3. The highest emission of Pseudomonas fluorescens from sewage to the air was observed at the point over the aeration chamber, where in the summer period the number of these bacteria exceeded two-fold 50 cfu.m3, which indicates strong air pollution. The largest number of haemolysing bacteria of type was found at all measurement stands in the spring-summer period, where their concentration from 0 to 48 cfu.m-3. The number of type bacteria determined in the air at the measurement points was within the range from 0 to 27 cfu.m-3, and the largest number was found at the point located over the aeration chamber. The study also involved the determination of the number of mannitol-positive staphylo-cocci, which values permissible for clean air should not exceed 100 cfu.m-3. Mannitol-positive staphylococci in the examined air oc-curred at a low level and in no samples exceeded the number for clean air proposed in the project PN-Z-04111-1 concerning air cleanliness protection. The concentration of potentially pathogenic bacteria of the Entero-bacteriaceae family was the highest in air samples collected in the vicini-ty of the sewage sludge storage place, where their number oscillated from 67 to 523 cfu.m-3, and at the screen site (22-320 cfu.m-3). The results of the study show that sludge-drying beds are an important source of micro-organism emission on the premises of a sewage treatment plant. The greatest number of microorganisms was found in air samples collected in late spring and summer. The exception was actinomyces, which occurred in the maximal amount in autumn. The assessment of degree of air pollu-tion indicates that there is a potential risk of exposure sewage treatment plant staff to harmful biological factors leading to disease incidence (bacteria of the Enterobacteriaceae family, and -haemolysing microor-ganisms and mannitol-positive staphylococci). The investigations show the need for constant monitoring of the effect of a sewage treatment plant on the air environment, which will enable efficient prevention of people working at sewage treatment plants.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1543-1558
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring stanu czystosci mikrobiologicznej wod Pradnika na terenie Ojcowskiego Parku Narodowego
Autorzy:
Chmiel, M
Zaprzelska, M.
Powiązania:
https://bibliotekanauki.pl/articles/797625.pdf
Data publikacji:
2006
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
czystosc mikrobiologiczna
rzeki
zanieczyszczenia mikrobiologiczne
monitoring
czystosc wod
Ojcowski Park Narodowy
rzeka Pradnik
microbiological purity
river
microbiological pollution
water purity
Ojcow National Park
Pradnik River
Opis:
W niniejszej pracy przedstawiono wyniki badań dotyczących czystości mikrobiologicznej wody rzeki Prądnik znajdującej się na obszarze Ojcowskiego Parku Narodowego. W ramach prowadzonych badań oznaczano liczebność bakterii mezofilnych, drożdży, grzybów pleśniowych oraz bakterii grupy coli. Uzyskane wyniki sugerują duże zmiany sezonowe w liczebności badanych grup mikroorganizmów zależne od temperatury powietrza i wody. Największe zanieczyszczenie mikrobiologiczne wody notowano w punktach położonych na terenie Ojcowa a najmniej skażone były próbki wody pobierane w punktach o dużej prędkości przepływu wody, zlokalizowane w bliskości źródeł zasilających potok oraz w oddaleniu od zabudowań gospodarczych. Potok Prądnik jest zbyt zanieczyszczony pod względem mikrobiologicznym, jak na ciek znajdujący się na terenie Parku Narodowego.
The paper presents the results of study on microbiological contamination of water of Prądnik river in the Ojcowski National Park area. The number of mesophilic bacteria, yeasts, moulds and MPN of coli group bacteria was examined. The obtained results suggest seasonal changes in the number of tested groups of microorganisms depending on the water and air temperature. A higher microbiological contamination of water was found in stations located in Ojców, while samples collected from stations of rapid water flow, located in the vacinity of the stream feeding sources, as well as those situated far from the farmhouses were least contaminated. Microbiological contamination of the Prądnik river far exceeded the limits expected for a stream situated within the boundaries of the National Park.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 2006, 515; 31-36
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena mikrobiologicznego zanieczyszczenia powietrza na terenie oczyszczalni ścieków
An assessment of microbiological air pollution at the sewage treatment plant
Autorzy:
Breza-Boruta, B.
Powiązania:
https://bibliotekanauki.pl/articles/339182.pdf
Data publikacji:
2010
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bioaerozol
oczyszczalnia ścieków
powietrze
air
bioaerosol
sewage treatment plant
Opis:
Przeprowadzono monitoringowe badania składu bioaerozolu bakteryjnego i mikrogrzybowego na terenie Oczyszczalni Ścieków Komunalnych "Igły" w Chojnicach. Analizy mikrobiologiczne powietrza wykonano w okresie letnim 2008 r. na czterech stanowiskach: przy piaskownikach, komorach napowietrzania, w miejscu składowania dojrzewającego kompostu i 150 m poza oczyszczalnią. Ogólna liczba bakterii wynosiła 10²-104 jtk·m-³ i tylko przy piaskownikach stwierdzono silne zanieczyszczenie powietrza. Największym emitorem bakterii wskaźnikowych P. fluorescens, pałeczek Salmonella sp. oraz paciorkowców kałowych również okazały się piaskowniki. Koncentracja grzybów pleśniowych była mała (maksymalnie 4 600 jtk·m-³) i na wszystkich stanowiskach nie przekraczała wartości, wskazujących na zanieczyszczenie powietrza. W przypadku promieniowców silne skażenie powietrza odnotowano jedynie przy pryzmach kompostowych. Gronkowce, zarówno mannitolododatnie, jak i mannitoloujemne, we wszystkich punktach przyczyniły się do średniego zanieczyszczenia powietrza. Pałeczki E. coli wykryto na dwóch stanowiskach – przy piaskownikach (92,5 jtk·m-³) i komorach napowietrzania (2,5 jtk·m-³). Na podstawie wyników uzyskanych w punkcie poza obiektem stwierdzono średnie zanieczyszczenie powietrza przez promieniowce, P. fluorescens oraz gronkowce, ponadto wykryto bakterie z rodzaju Salmonella i Enterococcus, co może świadczyć o skażeniu powietrza w najbliższym otoczeniu oczyszczalni ścieków.
Monitoring of the content of bacterial and microfungal bioaerosol was carried out at the Municipal Sewage Treatment Plant "Igły" in Chojnice. Microbiological analyses of the air were carried out in the summer period 2008 at four stands: in the vicinity of sand catchers, aeration chambers, maturing compost piles and at a distance of about 150 m from the treatment plant. The total number of bacteria remained within the range of 10²-104 cfu·m-³ and heavy air pollution occurred only by sand catchers. Concentration of mould fungi reached up to 4 600 cfu·m-³, which indicated unpolluted air at all stands. Sand catchers proved to be the largest emission source of indicator bacteria P. fluorescens, Salmonella sp. and fecal streptococci. In the case of actinomycetes, a heavy air pollution was noted at compost piles. Both mannitol-positive and mannitol-negative staphylococci at all points contributed to moderate air pollution. E. coli bacilli were isolated from two stands: near sand catchers (92.5 cfu·m-³) and aeration chambers (2.5 cfu·m-³). Moderate air pollution with actinomycetes, P. fluorescens and staphylococci was found outside the sewage treatment plant. Moreover, bacteria of the genera Salmonella and Enterococcus were detected, which may evidence air pollution in the immediate vicinity of the treatment plant.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2010, 10, 3; 49-57
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zanieczyszczenie mikrobiologiczne powietrza hal produkcyjnych zakładu przetwórstwa mięsnego jako potencjalne zagrożenie pracowników
Microbiological air pollution of production room of the meat processing plant as a potential threat to the workers
Autorzy:
Breza-Boruta, Barbara
Powiązania:
https://bibliotekanauki.pl/articles/1177520.pdf
Data publikacji:
2015
Wydawca:
Instytut Medycyny Wsi
Tematy:
"bioaerozol"
"grzyby pleśniowe"
"pracownicy"
"zakład mięsny"
Opis:
Introduction. Production rooms of the meat plants are the specific environment that require constant monitoring of microbiological air purity. Bioaerosols pose a threat to the safety of produced food and a considerable risk to health of exposed workers. The aim of this study was to estimate the air microbiological pollution in production rooms of the meat processing plant and exposure of the workers to biological aerosol. Material and methods. Air samples were collected at 3 stands in production rooms during winter, with the compaction method using the impactor MAS-100. The total number of bacteria and moulds, Staphylococci and bacteria of the family Enterobacteriaceae were determined in the studied bioaerosol. The concentration of microorganisms was presented in the form of colony forming units in 1m3 of air. Results. The highest concentration of mesophylic bacteria was found at stand 1 – at the freezing tunnel; whereas the highest contamination with staphylococci and fungal aerosol was found in the room where several workers were employed at packing frozen food. Among determined fungi predominated moulds of the genera: Penicillium, Alternaria and Cladosporium. Also species of potentially pathogenic fungi which produce toxins and have allergizing properties were detected in the studied bioaerosol. Bacteria of the family Enterobacteriaceae, which also may cause many infavourable health effects in exposed people, occurred at all stands. Conclusion. The concentration level and microbial composition in the inhaled air make valuable information for determination of occupational risk and a potential threat to workers of their workstations. Potentially pathogenic microorganisms present in the studied air (staphylococci, bacteria of the family Enterobacteriaceae and some moulds) according to the Directive 2000/54/EC l belong to the 2nd group of risk and threat of harmful biological agents. Identification of biological threats makes it easier for the employer to apply proper protection measures, and for the employees to feel obligated to use them.
Wstęp. Hale produkcyjne zakładów mięsnych są specyficznym środowiskiem wymagającym stałego monitorowania czystości mikrobiologicznej powietrza. Bioaerozole stanowią zagrożenie zarówno dla bezpieczeństwa produkowanej żywności, jak i zdrowia narażonych pracowników. Dlatego też, podjęto badania w celu określenia mikrobiologicznego zanieczyszczenia powietrza hal produkcyjnych zakładu przetwórstwa mięsnego oraz narażenia pracowników na aerozol biologiczny. Materiał i metody. Próbki powietrza pobierano na 3 stanowiskach w halach produkcyjnych w okresie zimowym, metodą zderzeniową przy użyciu impaktora MAS-100. W badanym bioaerozolu oznaczono ogólną liczbę bakterii i grzybów pleśniowych, gronkowce oraz bakterie z rodziny Enterobacteriaceae. Stężenie mikroorganizmów przedstawiono w postaci jednostek tworzących kolonie w 1m3 powietrza. Wyniki. Najwyższe stężenie bakterii mezofilnych stwierdzono na stanowisku 1 – przy tunelu zamrażalniczym. Natomiast największe skażenie gronkowcami oraz aerozolem grzybowym odnotowano w hali, gdzie kilkunastu pracowników pracowało przy pakowaniu mrożonek. Wśród oznaczonych grzybów dominowały pleśnie z rodzaju: Penicillium, Alternaria i Cladosporium. Wykryto również gatunki grzybów potencjalnie chorobotwórczych o właściwościach toksynotwórczych i alergizujących. W badanym bioaerozolu na wszystkich stanowiskach występowały bakterie z rodziny Enterobacteriaceae, które również mogą powodować wiele niekorzystnych skutków zdrowotnych u narażonych osób. Wnioski. Poziom koncentracji jak i skład drobnoustrojów we wdychanym powietrzu stanowią cenne informacje do określenia ryzyka zawodowego i potencjalnego zagrożenia dla pracowników zajmowanych stanowisk pracy. Obecne w badanym powietrzu potencjalnie chorobotwórcze drobnoustroje (gronkowce, bakterie z rodziny Enterobacteriaceae oraz niektóre grzyby pleśniowe) zgodnie z Dyrektywą 2000/54/WE należą do 2 grupy ryzyka i zagrożenia szkodliwymi czynnikami biologicznymi. Identyfikacja zagrożeń biologicznych ułatwia pracodawcy zastosowanie odpowiednich środków ochrony, a pracownikom obowiązku ich stosowania.
Źródło:
Medycyna Środowiskowa - Environmental Medicine; 2015, 18, 4; 37-42
1505-7054
2084-6312
Pojawia się w:
Medycyna Środowiskowa - Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bioaerosols of the Municipal Waste Landfill Site as a Source of Microbiological Air Pollution and Health Hazard
Bioaerozole składowiska odpadów komunalnych jako źródło mikrobiologicznego zanieczyszczenia powietrza i zagrożenia zdrowotnego
Autorzy:
Breza-Boruta, B.
Powiązania:
https://bibliotekanauki.pl/articles/389120.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
aerozol bakteryjny
aerozol grzybowy
promieniowce
bioaerozol
składowisko odpadów komunalnych
airborne bacteria
airborne fungi
Actinomycetes
bioaerosol
municipal waste landfill site
Opis:
The aim of this study was to determine the composition of bacterial and fungal aerosol on the premises of the Municipal Waste Disposal Complex at Zolwin-Wypaleniska near Bydgoszcz and to evaluate the degree of microbiological air pollution at the appointed stands. Microbial concentration in the air was determined at the waste sorting station and in the active sector of the landfill site as well as in the point situated 200 m beyond the facility. It was found that the total number of bacteria in the air ranged from 102 to 104 cfu ź m–3 and many times strong air pollution occurred on the premises of that facility. High concentration level of actinomycetes and indicator bacteria Pseudomonas flourescens contributed also to strong or moderate air pollution at research stands 1 and 2. Potentially pathogenic bacteria of the family Enterobacteriaceae (such as bacilli of Salmonella sp. and Escherichia coli) as well as faecal streptococci occurred in the largest amounts also at stands 1 and 2, and their number reached up to 103 cfu ź m–3. The obtained values show that both the sorting station the active sector of the waste landfill are serious emission sources of dangerous bacterial aerosol. They can pose a health hazard to the workers staying at those workstands. The determined amounts of fungal aerosol prove that it did not pose a microbiological hazard, and the studied air was described as moderately clean throughout the research period, only in the area of the sorting station it was polluted at several times. Among the isolated fungi, species of the genera Aspergillus and Penicillium predominated, as well as Sclerotinia sclerotorum. However, also potentially pathogenic species were detected in the studied air, such as: Aspergillus fumigatus, Cladosporium herbarium, Alternaria alternata etc. Their presence may affect the health of people (workers of the facility and residents of neighbouring areas) and the risk of the environmental pollution, since those species are well-known for their production of mycotoxins and inducing allergic reactions. Based on the registered concentrations of bacteria and fungi at the point 200 m away from the facility, it should be assumed that the studied air was not polluted and bioaerosol transmission from the sources of emission to the surrounding areas did not occur.
Celem pracy było oznaczenie składu bioaerozolu bakteryjnego i grzybowego na terenie Zakładu Unieszkodliwiania Odpadów Komunalnych w Żółwinie-Wypaleniska koło Bydgoszczy oraz ocena stopnia mikrobiologicznego zanieczyszczenia powietrza na wyznaczonych stanowiskach. Koncentrację mikroorganizmów w powietrzu określano na terenie sortowni odpadów i w sektorze czynnym składowiska oraz w punkcie położonym 200 m poza obiektem. Stwierdzono, że liczba bakterii ogółem w powietrzu kształtowała się od 102 do 104 jtk ź m-3 i doszło wielokrotnie do silnego zanieczyszczenia powietrza na terenie zakładu. Wysoki poziom koncentracji promieniowców i bakterii wskaźnikowych Pseudomonas fluorescens przyczynił się także do silnego lub średniego zanieczyszczenie powietrza na 1 i 2 stanowisku badawczym. Potencjalnie chorobotwórcze bakterie z rodziny Enterobacteriaceae (m.in. pałeczki Salmonella sp. i Escherichia coli) oraz paciorkowce kałowe w największych ilościach występowały również na stanowisku 1 i 2, a ich liczba dochodziła do 103 jtk ź m-3. Uzyskane wartości wskazują, że zarówno sortownia, jak i sektor czynny składowiska odpadów były poważnymi emitorami niebezpiecznego aerozolu bakteryjnego, zatem stanowić mogą zagrożenie zdrowotne dla pracowników przebywających na tych stanowiskach pracy. Oznaczona ilości aerozolu grzybowego świadczy, że nie stanowił on zagrożenia mikrobiologicznego, a badane powietrze określono jako przeciętnie czyste w całym okresie badawczym. Jedynie na terenie sortowni w kilku terminach doszło do jego skażenia. Wśród wyizolowanych grzybów dominowały gatunki z rodzaju Aspergillus i Penicillium oraz Sclerotinia sclerotorum. Jednakże wykryto w badanym powietrzu również gatunki potencjalnie chorobotwórcze, takie jak: Aspergillus fumigatus Cladosporium herbarium, Alternaria alternata i in. Ich obecność może wpływać na zdrowie ludzi (pracowników zakładu i mieszkańców przyległych terenów) oraz ryzyko skażenia środowiska, bowiem gatunki te znane są z produkcji mykotoksyn oraz wywoływania reakcji alergicznych. Na podstawie zarejestrowanego stężenia bakterii i grzybów w punkcie oddalonym 200 m od zakładu, należy przyjąć, że badane powietrze było niezanieczyszczone i nie doszło do przenoszenia bioaerozolu ze źródeł emisji na okoliczne tereny.
Źródło:
Ecological Chemistry and Engineering. A; 2012, 19, 8; 851-862
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagrożenia mikrobiologiczne w pomieszczeniach biurowych
Microbiological contaminants in office buildings
Autorzy:
Gołofit-Szymczak, M.
Skowroń, J.
Powiązania:
https://bibliotekanauki.pl/articles/180788.pdf
Data publikacji:
2005
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
zagrożenia mikrobiologiczne
zanieczyszczenie powietrza
pomieszczenia biurowe
microbiological hazards
air pollution
office space
Opis:
Czynnikami biologicznymi, na jakie może być narażony pracownik w pomieszczeniu biurowym, są bakterie, grzyby oraz wytwarzane przez nie struktury i substancje. W artykule zanieczyszczenia mikrobiologiczne, które mogą stanowić zagrożenie dla zdrowia osób narażonych na ich działanie. Mogą one wywoływać choroby alergiczne oraz infekcje dróg oddechowych.
Biological contamination of indoor air in office buildings includes bacteria and their spores, fungi, fungal spores and metabolic products from the microorganisms. Indoor biological contaminants can be responsible for a variety of adverse health effects. Physical symptoms related to biological contamination include allergy, hypersensitivity, and infectious diseases.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2005, 3; 29-31
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies