Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "metrological model" wg kryterium: Wszystkie pola


Tytuł:
Validation of the metrological model of coordinate measuring arm using multifeature check
Autorzy:
Gromczak, K.
Ostrowska, K.
Owczarek, D.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/957962.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
validation
metrological model
coordinate measuring arms
Opis:
The article presents the validation research scheme of metrological model of coordinate measuring arm (CMA) using multifeature check. The scheme shows the comparison of the calibration results of the check using selected coordinate methods and criteria of validation. The comparison shows the insignificance of differences between the obtained results of both: metrological model of CMA and multi-position method. It evidently proves the correctness of the development of metrological model of CMA. The use of appropriate quality multifeature check also had a significant impact on the results. This check is now the most accurate measurement length check and its use for this validation process was the most suitable.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 28; 120-124
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Triaxial Block of Navigation Accelerometer’s Metrological Model and Experimental Determination of its Parameters on the Uniaxial Rotary Stand
Autorzy:
Chernyak, N. G.
Palyushok, V. A.
Baranovska, I. M.
Powiązania:
https://bibliotekanauki.pl/articles/213906.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
three-axis accelerometers navigation unit
calibration
metrology model
Opis:
Metrology model of triaxial navigation accelerometer unit as a vector transmitter, physical and mathematical foundations of a new method for its calibration on uniaxial rotary stand are considered. The aim is to determine the coefficients of metrology model for triaxial accelerometer unit by the method mentioned above. To ensure the identifiability of all coefficients of the metrological model, two installations of accelerometer unit on a platform of uniaxial rotary stand were introduced. Identification models for metrology model of triaxial accelerometer unit were produced. Experimental validation of the obtained identification coefficients models was carried out. The ability to calibrate a triaxial accelerometer navigation unit with the given accuracy was confirmed.
Źródło:
Prace Instytutu Lotnictwa; 2014, 4 (237) December 2014; 13-22
0509-6669
2300-5408
Pojawia się w:
Prace Instytutu Lotnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The accuracy of the navigational accelerometer with a nonlinear metrological model in operating conditions
Dokładność nawigacyjnego akcelerometru z nieliniowym modelem metrologicznym w warunkach pracy
Autorzy:
Chernyak, Mycola
Kolesnyk, Vadym
Powiązania:
https://bibliotekanauki.pl/articles/36419664.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
navigational accelerometer
vibration error
metrological model
conversion function
identification of coefficients
static test
akcelerometr nawigacyjny
błąd drgań
model metrologiczny
funkcja konwersji
identyfikacja współczynników
próba statyczna
Opis:
A mathematical model of the error of the navigational accelerometer caused by the nonlinearity of its metrological model, taking into account the influence of vibration, was developed. The method of experimental estimation of the vibration error based on the developed model was proposed. The main idea of the method is to evaluate parameters of the developed model during static tests in the terrestrial gravitational field and to calculate error according to the specific vibration characteristics – the amplitude in the case of harmonic vibration profile or the frequency band and the power spectral density in the case of random vibration. The effectiveness of the proposed method has been tested using three types of navigation accelerometers in comparison with the results of classical dynamic testing in various vibration conditions (harmonic, white noise, etc.).
Opracowano model matematyczny błędu akcelerometru nawigacyjnego spowodowany nieliniowością jego modelu metrologicznego, uwzględniający wpływ wibracji. Zaproponowano metodę eksperymentalnego oszacowania błędu wibracji w oparciu o opracowany model. Główną ideą metody jest ocena parametrów opracowanego modelu podczas prób statycznych w ziemskim polu grawitacyjnym i obliczenie błędu zgodnie ze specyficznymi cechami drgań – amplitudą w przypadku profilu drgań harmonicznych lub pasma częstotliwości i spektrum mocy gęstość w przypadku drgań losowych. Skuteczność proponowanej metody została przetestowana przy użyciu trzech rodzajów akcelerometrów nawigacyjnych w porównaniu z wynikami klasycznych testów dynamicznych w różnych warunkach drgań (harmoniczne, biały szum itp.).
Źródło:
Transactions on Aerospace Research; 2020, 3 (260); 1-10
0509-6669
2545-2835
Pojawia się w:
Transactions on Aerospace Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza metrologiczna modelu miernika do pomiaru impedancji pętli zwarciowej metodą wektorową
Metrological analysis of model of a vector loop impedance meter
Autorzy:
Golijanek-Jędrzejczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/267970.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
metoda wektorowa
metrologia
impedancja
vector method
metrology
impedance
Opis:
W referacie zaprezentowano wyniki analizy metrologicznej modelu miernika do pomiaru impedancji pętli zwarcia metodą wektorową, uzyskane na podstawie symulacji przeprowadzonych w programie Mathcad. Przedstawiono wpływ przykładowych elementów miernika na dokładność pomiaru impedancji pętli oraz udział poszczególnych składowych błędu pomiaru impedancji.
This paper shows results of metrology analysis of loop impedance meter, which is based on vector method. Presented results are obtained through simulation in Mathcad. There are elements of the device influence on the accuracy of loop impedance measurement shown.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 25; 45-48
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model nadzoru metrologicznego nad urządzeniami procesowymi do pomiaru THT
A model of metrological supervision of process analyzers for THT measuring
Autorzy:
Huszał, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1834043.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
analizatory procesowe
nawanianie gazu
kontrola procesu nawaniania
process analyzers
gas odorization
odorization process control
Opis:
The increasing demand for process analyzers used in the supervision of the gaseous fuels odorizing process and the related higher and higher users’ requirements in terms of the quality of the results obtained lead to the growing need to verify the correctness of operation thereof and to confirm the reliability of measurement results. At present, however, there are no appropriate legal regulations concerning the control over this type of apparatus, as well as specifying the uncertainty level that the gas odorant concentration should be determined with. The normative regulations existing in this area are not unequivocal and can be interpreted in different ways, which leads to the situation when process equipment for measuring tetrahydrothiophene (THT) concentration in the gas can often lack proper metrological supervision. It is therefore necessary to properly select and verify appropriate methods to control the correctness of the process equipment indications and their implementation into the periodic check program. An extremely desirable method of supervision is to check or calibrate the analyzers in process conditions, without their dismantling for the time of checking. In turn, this entails the necessity to determine the possibility of conducting periodic metrological supervision over the measurement results correctness of THT process analyzers with the use of reference devices. The article presents a comparison of two methods currently used in metrological supervision of process analyzers for measuring the concentration of THT in the natural gas distribution gird. The results of checks of the proper functioning of these devices obtained by means of comparison with the laboratory test and the on-line comparative measurement method were analyzed. The conducted research verified the main sources of errors that have a significant impact on the correctness of results obtained by means of selected test methods. The results obtained showed the existence of a systematic error for the comparison method with a laboratory test. They also demonstrated the possibility of using the on-line comparative measurement method to carry out periodic calibrations or checks of the correct operation of THT analyzers in process conditions.
Źródło:
Nafta-Gaz; 2020, 76, 12; 955--963
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving metrological properties of electric traction energy meters using fuzzy controllers
Autorzy:
Dominikowski, B.
Pacholski, D.
Anuszczyk, J.
Gocek, A.
Powiązania:
https://bibliotekanauki.pl/articles/961423.pdf
Data publikacji:
2018
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
gain factor correction
traction meter
Mamdani model
Takagi-Sugeno model
korekcja współczynnika wzmocnienia
miernik trakcji
model Mamdaniego
model Takagi-Sugeno
Opis:
This paper presents the possibility of using a fuzzy controller to correct metrological properties of an electric traction energy meter. So far, no algorithms based on fuzzy logic to determine the desired conversion value of the current channel of the electricity meter have been applied. Currently, for the mentioned channel, conventional methods of gain determination are used, based on a sequential algorithm that controls operation of the programmable gain amplifier. The proposed corrector is designed for smart and continuous modification of the conversion factor of the low-voltage input part of the current channel in the electric energy meter. The authors have performed an accurate analysis of the current function in the main circuit of an electric locomotive by creating a model of a traction inverter subject to asynchronous motor load. An essential concept is this paper is to present the possibility of having a multi-input fuzzy controller split into two-input controllers connected in parallel and cascade. By performing a computer simulation of systems used for correcting metrological properties of electric traction energy meters, it has been proven that the applied fuzzy systems, based on an expert’s knowledge of digitally controlled PGA (Programmable Gain Amplifier) type operational amplifiers, are advantageous.
Źródło:
Transport Problems; 2018, 13, 1; 147-158
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza parametrów metrologicznych systemu pomiarowego tomografii impedancyjnej
Analysis of metrological parameters of measurement system for impedance tomography
Autorzy:
Wójtowicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/159407.pdf
Data publikacji:
2007
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
tomografia impedancyjna
model pomiaru
Opis:
Analiza metrologiczna torów pomiarowych umożliwia oszacowanie przedziałów ufności wielkości mierzonych i w konsekwencji rozkładu przestrzennego przedziałów ufności parametrów impedancyjnych. Artykuł przedstawia strukturę systemu pomiarowego, probabilistyczny model pomiaru w systemie wielowejściowym oraz analizę rozkładów składowych błędów. Do oszacowania przedziałów ufności zastosowano i porównano metodę propagacji przedziałów ufności i metodę propagacji rozkładów gęstości prawdopodobieństwa.
The metrological analysis of measuring chain enable to estimate a confidence interval of measured quantity as a consequence of confidence intervals for spatial distribution of impedance parameters. In the paper, the structure of measurement system, the probabilistic model of the measurement in multi-port system and the analysis of error components are presented. To estimate the confidence intervals a method of confidence interval propagation was applied as well this method with a method of probability density function propagation were compared.
Źródło:
Prace Instytutu Elektrotechniki; 2007, 230; 43-64
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System pomiarowo-sterujący jako metrologiczny obiekt badań
Measuring-control system as a metrological object of investigations
Autorzy:
Jakubiec, J.
Powiązania:
https://bibliotekanauki.pl/articles/158294.pdf
Data publikacji:
2004
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
system pomiarowo-sterujący
model propagacji błędów
obliczanie niepewności
measuring-control system
error propagation model
uncertainty calculation
Opis:
Artykuł zawiera charakterystykę badań prowadzonych w Instytucie Metrologii i Automatyki Elektechnicznej nad metrologicznymi właściwościami systemów pomiarowo-sterujących. W szczególności badania te doprowadziły do opracowania modeli przydatnych do opisu tego rodzaju właściwości systemów, w tym modelu realizacji zadań pomiarowych przez system, modelu błędu i modelu niepewności systemu. Modele te pozwalają na analizę błędów podstawowych ogniw procesu pomiarowego w systemie, takich jak przetworniki próbkujące i algorytmy przetwarzania programowego, a także błędów powodowanych opóźnieniami w realizacji zadań pomiarowych. Opisano model błędu systemu oraz odpowiadający mu model niepewności, który stanowi podstawę obliczania niepewności wyników wyjściowych systemu.
The paper characterizes the research made in the Institute of Electrical Measurement and Control Engineering on the metrological properties of the control-measuring systems. In particular, the investigations carried into development of the models useful for description of the system properties, such as the model of measurement task realization by the system, an error model and an uncertainty model of the system. These models enable error analysis of the basic elements of a measurement process in the system, such as sampling converters and measurement data processing algorithms, as well as analysis of errors caused by delays in measurement task realization. An error model of the system and, adequate to it, an uncertainty model, which is the basis of uncertainty calculation of the results at the system output, has been described.
Źródło:
Pomiary Automatyka Kontrola; 2004, R. 50, nr 6, 6; 8-13
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza numeryczno-doświadczalna przepływomierzy kolanowych
Numerical and experimental analysis elbow flow meters
Autorzy:
Gondek, A.
Sztaba, G.
Powiązania:
https://bibliotekanauki.pl/articles/277153.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
pomiar strumienia płynu
przepływomierz krzywakowy
właściwości metrologiczne
flow meter
flow model
metrological analysis
Opis:
W artykule przedstawiono wyniki badań doświadczalnych przepływomierzy kolanowych wybranych z seryjnie produkowanych elementów armatury (metalowa, plastikowa) w zakresie średnic 15-40 mm. Przeprowadzone badania symulacyjne przepływu wewnątrz kolana pozwoliły na przyjęcie odpowiedniego modelu prędkości, który był podstawą przy wyprowadzeniu teoretycznej zależności między wartością strumienia płynu a pomiarową różnicą ciśnienia Δp występującą miedzy zewnętrzną i wewnętrzną ścianą kolana. Na podstawie wyników badań i ich opracowania podano postać funkcji aproksymującej zależność współczynnika przepływu „μ" od geometrycznego współczynnika „ε" charakteryzującego kształt kolana.
The result of investigation on pipe elbow flow meter chosen from mass production elements of armature (metal, plastic) within the diameter range 15-40 mm have been presented in this article. The simulation research regarding distribution of the velocity within elbow allowed to chose proper model velocity profile. Basis on this velocity profile model a theoretical dependence of the value flow rate with elbow as the difference pressure Δp (between outer and inner wall elbow) has been defined. On the base of tests results and their calculation the calibration coefficient μ has been established as the function geometrical parameters ε characterizing shape of elbow.
Źródło:
Pomiary Automatyka Robotyka; 2011, 15, 1; 54-58
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane problemy metrologiczne oceny morfologicznej i funkcjonalnej stopy w leczeniu palucha koślawego
Selected metrological problems of morphological and functional foot assessment
Autorzy:
Wychowański, M.
Nowiński, K.
Borucki, B.
Wit, A.
Adamczyk, P.
Laskowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/156354.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
paluch koślawy
model szkieletu stopy
charakterystyka chodu
wskaźnik symetrii
hallux valgus
foot skeleton model
gait profile
symmetry index
Opis:
Paluch koślawy jest chorobą często występującą u kobiet. Wykonano RTG obu stóp w projekcji AP, bocznej i na palcach oraz MRI. Opracowano, trójwymiarowy model strukturalny szkieletu stopy. Przeanalizowano błędy wyznaczenia położeń poszczególnych znaczników. Zbadano równowagęu zdrowych osób metodą stabilograficzną. Pomiarów charakterystyk chodu dokonano na ścieżce podoskopowej. Względem młodszych kobiet przeprowadzono normowanie wyników starszych kobiet. Parametry charakteryzujące badane kobiety nie mają rozkładu normalnego. Profil chodu kobiet starszych opisano 19 parametrami. Różnice w chodzie obu badanych grup kobiet przejawiają się głównie w parametrach geometrycznych. Normy symetrii kobiet podano dla 1 kwartyla, mediany i 3 kwartyla.
Hallux valgus is one of the most frequent forefoot disease in women. There was taken RTG of both feet in the AP, lateral and tip toe projection as well as MRI. A three-dimensional structural foot skeleton model was developed. There was analysed the uncertainty of landmark positioning together with the influence on foot geometric features. Balance mechanism was examined in healthy subjects using the HUR stabilographic platform. Gait characteristics were made on the pressure distribution plate produced by ZEBRIS. There were separated two groups of younger women and a group of older women. Normalization of older women was carried out in relation to the younger group. The parameters characterizing the investigated women did not have a normal distribution. The gait profile of older women is based on 19 parameters. Differences in gait performance of both groups of women are mainly manifested in the geometric parameters. The norms of the symmetry index for the women are given as 1 quartile, median and 3 quartile.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 1, 1; 48-51
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies