Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "kolektory energii słonecznej" wg kryterium: Wszystkie pola


Wyświetlanie 1-5 z 5
Tytuł:
Metrological assurance of the sun energy collector testing
Badania i pomiary parametrów kolektorów energii słonecznej
Autorzy:
Yatsuk, V.
Stolyarchuk, P.
Mykyychuk, M
Dyak, R.
Serkez, K.
Oleskiv, T.
Powiązania:
https://bibliotekanauki.pl/articles/152765.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
solar energy collectors
metrological assurance
radiometers
temperature difference precision measurement
kolektory energii słonecznej
radiometry
precyzyjne pomiary różnicy temperatury
pomiary przepływu
Opis:
In this paper we present the accuracy analysis of energy and temperature measurements for testing and productivity improvement of solar collectors. There are presented possibilities of accuracy and resolution increase of solar energetic luminance sensors. The radiometer with electrical substitution was used in the research. The calibration procedure of the radiometer is described. A mathematical model of conversion function for both temperature and temperature difference measurement was developed as well.
W pracy przedstawiono analizę dokładności pomiaru energii słonecznej i temperatury za pomocą radiometrów z elektrycznym zrównoważeniem. W celu zwiększenia dokładności oraz rozdzielczości radiometrów zaproponowano zastosowanie połączonych równołegle miniaturowych sensorów diodowych do pomiaru różnicy temperatury powierzchni absorbującej kolektora słonecznego oraz otoczenia. Dodatkowo, diody te wykorzystano do nagrzewania sensora w czasie kompensowania. Pokazano, że taka konstrukcja sensora radiometrycznego pozwala odtwarzać temperaturę powierzchni przejmującej. Wykazano, że adytywne i multiplikatywne składniki błędów spowodowane rozrzutami technologicznymi napięć początkowych oraz prądów pomiarowych sensorów diodowych mogą być zmniejszone około razy, przy jednoczesnym zwiększeniu czułości w n razy, gdzie n jest liczbą równolegle połączonych diod. Opisano procedurę kalibracji radiometru przy zerowej i bliskiej maksymalnej mocy promieniowania. W pierwszym przypadku można skorygować addytywny, a w drugim – większość multiplikatywnych składników błędu. Zaproponowano schemat blokowy przyrządu do precyzyjnych pomiarów różnicy temperatury. Zastosowano wielokanałowe mierniki rezystancji z platynowymi sensorami temperatury. Do kalibrowania miernika różnicy temperatury wykorzystano precyzyjne miniaturowe rezystory, a do kalibrowania całego toru pomiarowego użyto precyzyjny termostat sterowany programowo. Opisano także konstrukcję stanowiska do pomiarów parametrów kolektorów słonecznych w laboratorium badawczym w Narodowym Uniwersytecie „Lwowska Politechnika”.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 9, 9; 901-904
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wykorzystania energii slonecznej do ogrzewania obiektow pod oslonami
Autorzy:
Kurpaska, S
Powiązania:
https://bibliotekanauki.pl/articles/804830.pdf
Data publikacji:
2002
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
tunele foliowe
kolektory sloneczne
systemy grzewcze
szklarnie
Opis:
W pracy przedstawiono wyniki obliczeń związanych z możliwością ogrzewania obiektów pod osłonami z wykorzystaniem energii słonecznej. Analizowane systemy grzewcze, oprócz standardowego kotła grzewczego, zawierały kolektory słoneczne oraz zbiornik akumulujący nadmiar energii cieplnej powstałej w ciągu dnia. Przeanalizowano powierzchnię kolektorów, pojemność akumulatora ciepła, uzależnionych od czasowej zmienności intensywności energii słonecznej, zmianą emisji substancji szkodliwych emitowanych do atmosfery oraz okres zwrotu zwiększonych nakładów inwestycyjnych poniesionych na budowę analizowanego systemu ogrzewania.
The paper presents the results of calculations related to the possibility of heating objects under covers with the use of solar energy. The analysed heating systems, beside a standard heating boiler, consisted of solar collectors and a reservoir accumulating the surplus thermal energy produced during a day. The following parameters were subject to analysis: the collectors area and the thermal accumulator capacity that were dependent on variation of the solar energy intensity with time, changes of emission of harmful substances into atmosphere, the return period of higher investment costs per building of the analysed heating system.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 2002, 485; 177-185
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pozyskiwanie energii słonecznej w warunkach zabudowy miejskiej
Solar energy gaining in condition of urban areas
Autorzy:
Ziembicki, P.
Bernasiński, J.
Powiązania:
https://bibliotekanauki.pl/articles/372049.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
energia odnawialna
kolektory słoneczne
nasłonecznienie
budynki wielorodzinne
sprawność kolektorów
renewable energy
solar collectors
insolation
municipal buildings
solar collectors efficiency
Opis:
W publikacji przedstawiono analizę zasobów energii słonecznej możliwej do wykorzystania w warunkach zabudowy miejskiej. Przeanalizowano parametry wpływające na sprawność pozyskiwania energii słonecznej, a także zaproponowano rozwiązania integracji układów solarnych ze źródłami ciepła. Przeprowadzono analizę metod pozyskiwania energii słonecznej oraz wskazano rozwiązanie dla warunków zabudowy miejskiej.
The paper presents an analysis of solar energy resources that can be utilize in urban conditions. We analyzed the factors influencing the efficiency of solar energy gaining, and also indicated the solution for the integration of solar systems with heat sources. In the paper we presented the various methods of solar energy gaining and indicated the solution for the urban conditions.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2010, 140 (20); 120-132
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature verification method of solar heat gains in installations with flat plate solar collectors – case study
Metoda temperaturowej weryfikacji solarnych uzysków ciepła w instalacji z kolektorami płaskimi – studium przypadku
Autorzy:
Olczak, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1840777.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
measurement
solar energy
solar heat sources
energy efficiency measures
thermal solar collector
pomiary
energia słoneczna
kolektory słoneczne termiczne
źródła energii słonecznej
pomiar efektywności energetycznej
Opis:
Solar collectors are used increasingly in single-family housing. Their popularity depends on many factors, including the price-to-productivity ratio, which in turn results from the development of solar collector technology as well as entire systems. This development consists of many aspects, including those related to the modernization of control systems and measuring of solar collector systems. Currently used systems offer, among others, the ability to determine the approximate solar heat gains using the sensors necessary for normal control of the sensor system. The paper analyzes, on the example of one facility, how such installations work in Polish conditions. An installation consisting of 3 solar collectors has been selected for analysis, supporting the preparation of hot utility water for a single-family residential building. The detailed analysis concerned days with high heat gains compared to the average heat demand for hot water preparation in the building. The temperature verification method (TVM) of the calculated solar heat gains by the solar system controller has been proposed. Then, differences in measurements according to two methods (controller and TVM) have been presented at various characteristic moments of the installation’s operation (start- -up, stop) and during continuous operation. It has been shown that during the day gains measured by the controller can be 15% lower than gains measured by the TVM method. The check has been carried out at a daily sunlight value higher than 4.8 kWh/m2 measured on a horizontal plane. The ratio of heat energy supplied to the domestic hot water storage tank to the measured insolation has been 34%. The sum of annual solar heat gains measured by the controller and TVM differed by 5.2%.
W budownictwie jednorodzinnym coraz częściej stosuje się kolektory słoneczne. Ich popularność zależy od wielu czynników, w tym stosunku ceny do wydajności, co z kolei wynika z rozwoju technologii kolektorów słonecznych, a także całych systemów. Na rozwój ten składa się wiele aspektów, w tym związanych z modernizacją układów sterowania i pomiarami systemów kolektorów słonecznych. Obecnie stosowane systemy oferują m.in. możliwość określenia przybliżonych uzysków ciepła słonecznego za pomocą czujników niezbędnych do normalnego sterowania układem pracy systemu. W artykule przeanalizowano, na przykładzie jednego obiektu, jak takiego typu instalacje działają w polskich warunkach. Do analizy wybrano instalację składającą się z 3 kolektorów słonecznych wspomagających przygotowanie ciepłej wody użytkowej dla budynku mieszkalnego jednorodzinnego. Szczegółowa analiza dotyczyła dni z dużymi uzyskami ciepła w porównaniu ze średnim zapotrzebowaniem na ciepło do przygotowania ciepłej wody w budynku. Zaproponowano metodę weryfikacji temperatury (TVM) obliczonych zysków ciepła słonecznego przez regulator systemu solarnego. Następnie przedstawiono różnice w pomiarach prowadzonych dwiema metodami (sterownik PLUM i TVM) w różnych charakterystycznych momentach pracy instalacji (rozruch, zatrzymanie) oraz podczas pracy ciągłej. Wykazano, że w ciągu dnia uzyski ciepła mierzone przez kontroler mogą być o 15% niższe niż uzyski mierzone metodą TVM. Sprawdzenie zostało przeprowadzone przy dziennej wartości nasłonecznienia wyższej niż 4,8 kWh/m2 mierzonego w płaszczyźnie poziomej. Stosunek energii cieplnej dostarczonej do zasobnika ciepłej wody użytkowej do zmierzonego nasłonecznienia wyniósł 34%. Suma rocznych uzysków ciepła słonecznego mierzonych przez regulator i TVM różniła się o 5,2%.
Źródło:
Polityka Energetyczna; 2021, 24, 1; 115-132
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The design of a model for a 1 MW parabolic trough concentrated solar power plant in Sudan using TRNSYS software
Projekt modelu skoncentrowanej elektrowni słonecznej z rynną paraboliczną o mocy 1 MW w Sudanie z wykorzystaniem oprogramowania TRNSYS
Autorzy:
Jebreel, Abdelkareem Abdallah Abdelkareem
Hamad, Hamad Mohamed Ali
Powiązania:
https://bibliotekanauki.pl/articles/2127504.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
thermal storage
thermal solar collectors
photovoltaic solar panel
renewable source of energy
solar power plants
magazynowanie ciepła
termiczne kolektory słoneczne
fotowoltaiczne panele słoneczne
odnawialne źródła energii
elektrownie słoneczne
Opis:
Solar photovoltaic (PV) and concentrated solar power (CSP) systems are the present worldwide trends in utilizing solar energy for electricity generation. Solar energy produced from photovoltaic cells (PV) is considered the main common technology used due to its low capital cost; however, the relatively low efficiency of PV cells has spotlighted development and research on thermal engine applications using concentrated solar power. The efficiency of concentrated solar power is greater than that of PV and considering the solar potential for Sudan. Therefore, this study has been performed in an attempt to draw attention to the utilization of CSP in Sudan since the share of CSP is insignificant in comparison with PV, besides the suitability of CSP applications to Sudan’s hot climate and the high solar energy resource, the study presents a design model of 1 MW parabolic trough collectors (PTC) using the Rankine cycle with thermal energy storage (TES) in Sudan, by adopting reference values of the Gurgaon PTC power plant in India. The design of a 1 MW Concentrated Solar thermal power plant using parabolic trough collectors (PTC) and thermal energy storage is proposed. The simulation was performed for a site receiving an annual direct normal irradiance (DNI) of 1915 kWh/m2, near Khartoum. The results showed that the plant can produce between nearly 0.6 to 1 MWh during the year, and around 0.9 MWh when it encompasses thermal energy storage with an average thermal efficiency of 24%. These results of the PTC Power plant encourage further investigation and the development of CSP technologies for electricity generation in Sudan.
Systemy fotowoltaiczne (PV) i skoncentrowanej energii słonecznej (CSP) to obecne światowe trendy w wykorzystywaniu energii słonecznej do wytwarzania energii elektrycznej. Energia słoneczna wytwarzana z ogniw fotowoltaicznych (PV) jest uważana za główną powszechnie stosowaną technologię ze względu na jej niski koszt kapitałowy, jednak stosunkowo niska wydajność ogniw fotowoltaicznych zwróciła uwagę na rozwój i badania nad zastosowaniami silników cieplnych wykorzystujących skoncentrowaną energię słoneczną. W warunkach posiadanego potencjału słonecznego Sudanu wydajność skoncentrowanej energii słonecznej jest większa niż PV. Dlatego niniejsze badanie zostało przeprowadzone w celu zwrócenia uwagi na wykorzystanie CSP w Sudanie, ponieważ udział CSP jest nieznaczny w porównaniu z PV, pomimo przydatności zastosowań CSP do gorącego klimatu Sudanu i wysokich zasobów energii słonecznej. W pracy przedstawiono projekt modelu parabolicznych kolektorów rynnowych (PTC) o mocy 1 MW z wykorzystaniem cyklu Rankine’a z magazynowaniem energii cieplnej (TES) w Sudanie, przyjmując wartości referencyjne elektrowni Gurgaon PTC w Indiach. Zaproponowano projekt elektrowni słonecznej o mocy 1 MW wykorzystującej paraboliczne kolektory rynnowe (PTC) i magazynowanie energii cieplnej. Symulacja została przeprowadzona dla miejsca zlokalizowanego koło Chartumu, o rocznym bezpośrednim napromieniowaniu normalnym (DNI) 1915 kWh/m2. Wyniki pokazały, że elektrownia może wyprodukować od prawie 0,6 do 1 MWh w ciągu roku i około 0,9 MWh, przy wykorzystaniu magazynowanie energii cieplnej ze średnią sprawnością cieplną 24%. Te wyniki elektrowni PTC zachęcają do dalszych badań i rozwoju technologii CSP do wytwarzania energii elektrycznej w Sudanie.
Źródło:
Polityka Energetyczna; 2022, 25, 3; 67--90
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies