Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "insulation diagnostics" wg kryterium: Wszystkie pola


Tytuł:
Monitoring stanu izolacji uzwojeń maszyn elektrycznych w przemyśle – przykład aplikacji Część I
Monitoring of condition of winding insulations in electrical machines in the industry – an example application. Part I
Autorzy:
Szymaniec, S.
Powiązania:
https://bibliotekanauki.pl/articles/1201924.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
diagnostyka izolacji uzwojeń wysokonapięciowych maszyn elektrycznych
insulation diagnostics of high voltage electric machines
Opis:
Operation of electric machines is accompanied by partial discharges. Partial discharges have a very complex nature. Together with progressing use of machines, there is a change in the intensity of partial discharges with typical phase-resolved distributions. The diagnostics can be carried out using available partial charge detectors. Results of measurements of partial discharges in motors depend on: the condition of their insulation, motor load, temperature of windings, humidity, level of external interference, and characteristics of partial discharge detectors and partial discharge analysing devices.
Pracy maszyn elektrycznych towarzyszą wyładowania niezupełne. Charakter wnz jest bardzo złożony. W miarę upływu czasu eksploatacji maszyn, obserwuje się zmianę intensywności wnz przy charakterystycznych rozkładach fazowo-rozdzielczych. Diagnostykę można prowadzić w oparciu o wszystkiedostępne czujniki wnz. Wyniki pomiarów wnz silników zależą od: stanu ich izolacji, obciążenia silnika,temperatury uzwojeń, wilgotności, poziomu zakłóceń zewnętrznych oraz od charakterystyki czujników wnz i aparatury analizującej wnz.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 2, 110; 71-76
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring stanu izolacji uzwojeń maszyn elektrycznych w przemyśle - przykład aplikacji część II
Monitoring of condition of winding insulations in electrical machines in the industry – an example application. Part II
Autorzy:
Szymaniec, S.
Powiązania:
https://bibliotekanauki.pl/articles/1367243.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
diagnostyka izolacji uzwojeń wysokonapięciowych maszyn elektrycznych
insulation diagnostics of high voltage electric machines
Opis:
Operation of electric machines is accompanied by partial discharges. Partial discharges have a very complex nature. Together with progressing use of machines, there is a change in the intensity of partial discharges with typical phase-resolved distributions. The diagnostics can be carried out using available partial charge detectors. Results of measurements of partial discharges in motors depend on: the condition of their insulation, motor load, temperature of windings, humidity, level of external interference, and characteristics of partial discharge detectors and partial discharge analysing devices.
Pracy maszyn elektrycznych towarzyszą wyładowania niezupełne. Charakter wnz jest bardzo złożony. W miarę upływu czasu eksploatacji maszyn, obserwuje się zmianę intensywności wnz przy charakterystycznych rozkładach fazowo-rozdzielczych. Diagnostykę można prowadzić w oparciu o wszystkie dostępne czujniki wnz. Wyniki pomiarów wnz silników zależą od: stanu ich izolacji, obciążenia silnika, temperatury uzwojeń, wilgotności, poziomu zakłóceń zewnętrznych oraz od charakterystyki czujników wnz i aparatury analizującej wnz.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 2, 110; 77-82
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aparaturowe aspekty pomiaru wyładowań niezupełnych maszyn elektrycznych. Część 1
Equipment aspects of electric machine diagnostics based on a pd. Part I
Autorzy:
Paduch, Piotr
Szymaniec, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/303290.pdf
Data publikacji:
2019
Wydawca:
Wydawnictwo Druk-Art
Tematy:
wysokie napięcie
maszyny elektryczne
diagnostyka izolacji maszyn elektrycznych
high voltage
electric machines
insulation diagnostics
Opis:
Według autorów, w przodujących ośrodkach naukowo-badawczych zajmujących się diagnostyką stanu izolacji uzwojeń maszyn elektrycznych zauważyć można cztery kierunkowe obszary prac badawczych: prace nad opracowywaniem nowych konstrukcji czujników do pomiarów wnz; prace nad opracowaniem uniwersalnego analizatora wnz z ulepszonymi osiągami w zakresie tłumienia szumów i zakłóceń; prace nad opracowaniem urządzeń przenośnych, mobilnych; prace nad opracowaniem coraz to bardziej złożonych analizatorów, umożliwiających pomiary i analizę sygnałów wnz w bardzo szerokim zakresie czasu i częstotliwości; analizatory te umożliwiają wyznaczenie np. funkcji korelacji.
Operation of electric machines is accompanied by partial discharges. Partial discharges have a very complex nature. Together with progressing use of machines, there is a change in the intensity of partial discharges with typical phase-resolved distributions. The diagnostics can be carried out using available partial charge detectors. The author’s solutions regarding detectors and devices for measurements of partial discharges in electric machines in industrial conditions have proved to be successful. Results of measurements of partial discharges in motors depend on: the condition of their insulation, motor load, temperature of windings, humidity, level of external interference, and characteristics of partial discharge detectors and partial discharge analysing devices.
Źródło:
Napędy i Sterowanie; 2019, 21, 5; 58-63
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aparaturowe aspekty pomiaru wyładowań niezupełnych maszyn elektrycznych - część II
Equipment aspects of electric machine diagnostics based on a PD - part II
Autorzy:
Paduch, P.
Szymaniec, S.
Powiązania:
https://bibliotekanauki.pl/articles/2056390.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
diagnostyka izolacji uzwojeń wysokonapięciowych maszyn elektrycznych
insulation diagnostics of the high voltage electric machines
Opis:
Pracy maszyn elektrycznych towarzyszą wyładowania niezupełne. Charakter wnz jest bardzo złożony. W miarę upływu czasu eksploatacji maszyn, obserwuje się zmianę intensywności wnz przy charakterystycznych rozkładach fazowo-rozdzielczych. Diagnostykę można prowadzić w oparciu o wszystkie dostępne czujniki wnz. Proponowane przez autora własne rozwiązania czujników i przyrządów do pomiarów wnz w maszynach elektrycznych w warunkach przemysłowych sprawdziły się. Wyniki pomiarów wnz silników zależą od: stanu ich izolacji, obciążenia silnika, temperatury uzwojeń, wilgotności, poziomu zakłóceń zewnętrznych oraz od charakterystyki czujników wnz i aparatury analizującej wnz.
Operation of electric machines is accompanied by partial discharges. Partial discharges have a very complex nature. Together with progressing use of machines, there is a change in the intensity of partial discharges with typical phase-resolved distributions. The diagnostics can be carried out using available partial charge detectors. The author’s solutions regarding detectors and devices for measurements of partial discharges in electric machines in industrial conditions have proved to be successful. Results of measurements of partial discharges in motors depend on: the condition of their insulation, motor load, temperature of windings, humidity, level of external interference, and characteristics of partial discharge detectors and partial discharge analysing devices.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 2, 118; 39--46
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aparaturowe aspekty pomiaru wyładowań niezupełnych maszyn elektrycznych - część I
Equipment aspects of electric machine diagnostics based on a PD - part I
Autorzy:
Paduch, P.
Szymaniec, S.
Powiązania:
https://bibliotekanauki.pl/articles/2056397.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
diagnostyka izolacji uzwojeń wysokonapięciowych maszyn elektrycznych
insulation diagnostics of the high voltage electric machines
Opis:
Pracy maszyn elektrycznych towarzyszą wyładowania niezupełne. Charakter wnz jest bardzo złożony. W miarę upływu czasu eksploatacji maszyn, obserwuje się zmianę intensywności wnz przy charakterystycznych rozkładach fazowo-rozdzielczych. Diagnostykę można prowadzić w oparciu o wszystkie dostępne czujniki wnz. Proponowane przez autora własne rozwiązania czujników i przyrządów do pomiarów wnz w maszynach elektrycznych w warunkach przemysłowych sprawdziły się. Wyniki pomiarow wnz silnikow zależą od: stanu ich izolacji, obciążenia silnika, temperatury uzwojeń, wilgotności, poziomu zakłoceń zewnętrznych oraz od charakterystyki czujników wnz i aparatury analizującej wnz.
Operation of electric machines is accompanied by partial discharges. Partial discharges have a very complex nature. Together with progressing use of machines, there is a change in the intensity of partial discharges with typical phase-resolved distributions. The diagnostics can be carried out using available partial charge detectors. The author’s solutions regarding detectors and devices for measurements of partial discharges in electric machines in industrial conditions have proved to be successful. Results of measurements of partial discharges in motors depend on: the condition of their insulation, motor load, temperature of windings, humidity, level of external interference, and characteristics of partial discharge detectors and partial discharge analysing devices.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 2, 118; 29--37
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka izolacji uzwojeń wysokonapięciowych maszyn elektrycznych wykonanych w technologii Resin-Rich na etapie produkcji
Insulation Diagnostics of the High Voltage Electric Machines Made in Resin-Rich Technology During Manufacturing
Autorzy:
Szymaniec, S.
Kandora, W.
Powiązania:
https://bibliotekanauki.pl/articles/1368412.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
diagnostyka izolacji uzwojeń wysokonapięciowych maszyn elektrycznych
insulation diagnostics of high voltage electric machines
Opis:
Paper contain laboratory study of partial discharge (PD) measurement on turbogenerator bars with a voids. Partial discharge patterns and PD interpretation were showed.
W artykule przedstawiono badania laboratoryjne prętów stojana turbogeneratora, przedstawiono wyniki pomiarów, jak również ich interpretację.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 2, 99; 37-42
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka izolacji uzwojeń wysokonapięciowych maszyn elektrycznych wykonanych w technologii resin-rich na etapie produkcji i remontu
Insulation Diagnostics of the High Voltage Electric Machines Made in Resin-Rich Technology During Manufacturing and Repair
Autorzy:
Szymaniec, S.
Kandora, W.
Powiązania:
https://bibliotekanauki.pl/articles/1368192.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
diagnostyka izolacji uzwojeń wysokonapięciowych maszyn elektrycznych
insulation diagnostics of high voltage electric machines
Opis:
Paper contain laboratory study of partial discharge (PD) measurement on turbogenerator bars with a voids. Partial discharge patterns and PD interpretation were showed.
W artykule przedstawiono badania laboratoryjne prętów stojana turbogeneratora, przedstawiono wyniki pomiarów jak również ich interpretację.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 3, 100/1; 189-194
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a Phase Resolved Partial Discharge Pattern Analysis for Acoustic Emission Method in High Voltage Insulation Systems Diagnostics
Autorzy:
Kunicki, M.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/177912.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
insulation system
Opis:
An alternative method for analysis of acoustic emission (AE) signals generated by partial discharges (PD), based on a correlation between voltage phase run and AE pulses, so called phase resolved PD pattern (PRPD), is presented in the paper. PRPD pattern is a well-known analysis tool commonly used in such PD diagnostic methods as conventional electrical and UHF ones. Moreover, it yields various signal analysis abilities and allows a direct correlation indication between measurement results achieved using different methods. An original PRPD measurement methodology applied for AE method as well as some exemplary measurement results and further data analysis capabilities are presented in the paper. Also a comparative analysis of PRPD patterns achieved using various measurement methods and different PD source configurations have been investigated. All presented experiments were done under laboratory conditions using PD model sources immersed in the insulation oil. The main purpose of the presented research is to indicate an all-embracing analytical tool that yields an ability to direct comparison (qualitative as well as quantitative) of the AE measurement results with other commonly applied PD measurement methods. The presented results give a solid fundamental for further research work concerning a direct correlation method for AE and other described in the paper diagnostic techniques, mainly in order to continue PD phenomena analysis and assessment in real life high voltage apparatus insulation systems under normal onsite operation conditions.
Źródło:
Archives of Acoustics; 2018, 43, 2; 235-243
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka stanu izolacji silników indukcyjnych wysokonapięciowych off-line w przemyśle
Diagnostics of insulation high voltage induction motor off-line in in-dustry
Autorzy:
Szymaniec, S.
Powiązania:
https://bibliotekanauki.pl/articles/1374814.pdf
Data publikacji:
2005
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
diagnostyka silników indukcyjnych
silniki indukcyjne
izolacja elektryczna
Opis:
The article presents an application of diagnostic insulation high voltage induction motor off-line in industry. The paper contains an analysis of different diagnostics methods. It the usefulness of method was has talked over was in peculiarity using measurements PI, C, DD i SV - Polarization Index Testing, Capacitance, Dielectric Discharge Testing, Step Voltage Testing. The examples of results of measurements state isolation interesting industrial cases were passed.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2005, 71; 77-82
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aktualne możliwości i perspektywy zastosowania metody emisji akustycznej w diagnostyce układów izolacyjnych
Present possibilities and prospects of the acoustic method application in diagnostics of insulation systems
Autorzy:
Skubis, J.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/153254.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metoda emisji akustycznej
wyładowania niezupełne
system ekspercki
acoustic emission method
partial discharges
expert system
Opis:
W artykule zostały scharakteryzowane prowadzone obecnie przez autorów artykuły prace związane z doskonaleniem akustycznej metody pomiaru wyładowań elektrycznych, jakie mogą występować w układach izolacyjnych urządzeń elektroenergetycznych. Szczególną uwagę zwrócono na ekspercki system diagnostyczny wykorzystujący metodę emisji akustycznej do oceny stanu mierzonej izolacji transformatorów energetycznych.
The paper characterizes the research work on the improvement of the acoustic method of the measurements of electrical discharges that can occur in insulation systems of power appliances. The utmost attention was directed to the expert diagnostic system using the acoustic emission method for the evaluation of the condition of the power transformer insulation measured.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 10, 10; 44-45
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka transformatorów olejowych hermetycznych i suchych
Diagnostics of hermetic and dry oil transformers
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2135015.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
izolacja główna
izolacja międzyzwojowa
badania diagnostyczne
transformer
main insulation
interturn insulation
diagnostic tests
Opis:
Diagnostyka transformatorów suchych i transformatorów olejowych hermetycznych obejmuje pomiar rezystancji uzwojeń, diagnostykę izolacji głównej i izolacji międzyzwojowej. Diagnostykę izolacji głównej przeprowadza się napięciem zmiennym i napięciem stałym. Napięciem zmiennym wykonuje się pomiar współczynnika stratności tgδ. Napięciem stałym przeprowadza się pomiar rezystancji R60, oraz w rozszerzonym zakresie badania polaryzacyjne. Badanie izolacji międzyzwojowej polega na rejestracji przebiegu napięcia na uzwojeniu po skokowym wyłączeniu prądu stałego.
Oil testing is not performed in hermetic oil transformers. Diagnostics of dry transformers and hermetic oil transformers include winding resistance measurement, diagnostics of main insulation and turn-to-turn insulation. Main insulation diagnostics are performed with alternating voltage and direct voltage. The loss factor tgδ is measured with the alternating voltage. The resistance R60, is measured with direct voltage, and in the extended range of polarization tests. The test of interturn insulation is based on the registration of the voltage waveform on the winding after a DC switching off.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 21--27
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie napięcia stałego do badań izolacji głównej maszyn elektrycznych dużej mocy
Application of DC voltage in insulation to ground tests for high power electrical machines
Autorzy:
Zientek, Piotr
Łukaszewicz-Szmytka, Waleria
Czempik, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/303119.pdf
Data publikacji:
2019
Wydawca:
Wydawnictwo Druk-Art
Tematy:
maszyny elektryczne
diagnostyka maszyn
remont maszyn
pomiar izolacji
electrical machines
machine diagnostics
machine repair
insulation measurement
Opis:
Diagnostyka układu izolacyjnego uzwojeń maszyn elektrycznych napięciem stałym jest najprostszą metodą oceny stanu technicznego izolacji. Prostota pomiaru tą metodą, małe gabaryty sprzętu pomiarowego oraz szybkość otrzymania wyników sprawiają, że metody wykorzystujące napięcie stałe są powszechnie stosowane do ogólnej, a nawet zaawansowanej oceny stopnia zużycia izolacji. Wyznaczone parametry elektryczne układu izolacyjnego są parametrami kryterialnymi, według których można w sposób jednoznaczny ocenić stan techniczny izolacji uzwojenia.
DC voltage diagnostics of insulation system of electrical machines is the most straightforward method of assessing technical condition of insulation. The simplicity of DC voltage tests, small dimensions of measurement apparatus and rapid conclusions result in the fact, that these methods are universally used in general and even advanced evaluation of insulation’s degree of wear. Electrical parameters of insulation system determined with DC voltage are criteria parameters. Technical condition of winding insulation may be unambiguously assessed with the help of these parameters.
Źródło:
Napędy i Sterowanie; 2019, 21, 10; 74-82
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody badań izolacji głównej maszyn elektrycznych dużej mocy przy wykorzystaniu napięcia stałego
Insulation to ground dc test procedures for high power electrical machines
Autorzy:
Zientek, Piotr
Łukaszewicz-Szmytka, Waleria
Czempik, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1196794.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne
diagnostyka i remonty maszyn
pomiar izolacji
electrical machines
machine diagnostics and repairs
insulation measurement
Opis:
DC voltage diagnostics of insulation system of electrical machines is the most straightforward method of assessing technical condition of insulation.. The simplicity of DC voltage tests, small dimensions of measurement apparatus and rapid conclusions result in the fact, that these methods are universally used in general and even advanced evaluation of insulation’s degree of wear. Electrical parameters of insulation system determined with DC voltage are criteria parameters. Technical condition of winding insulation may be unambiguously assessed with the help of these parameters.
Diagnostyka układu izolacyjnego uzwojeń maszyn elektrycznych napięciem stałym jest najprostszą metodą oceny stanu technicznego izolacji. Prostota pomiaru tą metodą, małe gabaryty sprzętu pomiarowego oraz szybkość otrzymania wyników sprawia, że metody wykorzystujące napięcie stałe są powszechnie stosowane do ogólnej a nawet zaawansowanej oceny stopnia zużycia izolacji. Wyznaczone parametry elektryczne układu izolacyjnego są parametrami kryterialnymi, według których można w sposób jednoznaczny ocenić stan techniczny izolacji uzwojenia
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2019, 2, 122; 27-34
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary rezystancji izolacji silników elektrycznych
Measurements of insulation resistance of electric motors
Autorzy:
Olesz, Marek
Kostro, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/267037.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
rezystancja izolacji
diagnostyka
eksploatacja
insulation resistance
diagnostics
exploitation
Opis:
W artykule podano zasady wykonywania pomiarów rezystancji izolacji maszyn elektrycznych. Przedstawiono dostępne w literaturze temperaturowe współczynniki korekcyjne konieczne do przeliczania zmierzonych wartości rezystancji na wartość występującą w temperaturze odniesienia. Obserwowane różnice współczynników temperaturowych wynikają z rodzaju zastosowanego materiału izolacji, konstrukcji silnika oraz technologii impregnowania uzwojeń.
The paper presents principles for insulation resistance measurements of electric motors. The temperature correction coefficients available in the literature to converting the measured resistance value into a value occurring at the reference temperature were analyzed. Occurred differences of temperature coefficients results from the insulation type, construction of the motor and winding impregnation technology.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 64; 29-32
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The device for diagnostics of condition of heat-insulation of heating systems
Układ diagnostyczny do badania stanu cieplnej izolacji systemu przesyłania ciepła
Autorzy:
Prudyus, I.
Storozh, V.
Turkinov, G.
Shkliarskiy, V.
Powiązania:
https://bibliotekanauki.pl/articles/208589.pdf
Data publikacji:
2011
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
systemy grzewcze
izolacja cieplna
diagnostyka
heating systems
heat insulation
diagnostics
Opis:
Diagnostics of the modern thermal systems is very important from the economic and reliability point of view. The paper presents the solution of the device for monitoring the isolation of the heat transmission line. The principle of its operation applies the wave model of the line. Any damage of isolation results in change of the parameters of this model and change of the measured input resistance of the line. Through the electronic system, this change is transformed to the indication of the actual state of the isolation.
Diagnostyka izolacji w systemie linii przesyłowych ciepła odgrywa ważną rolę w ekonomice przesyłu i pewności działania systemu grzewczego. Praca przedstawia układ diagnostyczny pozwalający stwierdzić uszkodzenie izolacji. Zasada działania urządzenia wykorzystuje model falowy linii przesyłowej. Uszkodzenie izolacji powoduje zmianę parametrów modelu linii i związaną z tym zmianę rezystancji wejściowej. Zmiana ta poprzez układ elektroniczny czujników jest przetwarzana na sygnalizację LCD uszkodzenia. Praca przedstawia szczegóły rozwiązania takiego układu.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2011, 60, 1; 29-36
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies