Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "indoor exposure" wg kryterium: Wszystkie pola


Tytuł:
A new scheme of the environmental classification standards for the bronze cultural relic’s preservation in museums
Autorzy:
Li, Dandan
Zhou, Hao
Xu, Fangyuan
Yan, Ying
Wu, Laiming
Cai, Lankun
Powiązania:
https://bibliotekanauki.pl/articles/28407393.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
QCM
temperature
humidity
indoor exposure
cultural relics
mikrowaga kwarcowa
temperatura
wilgotność
ekspozyja w pomieszczeniach
zabytki kultury
Opis:
The environmental risk classification of the metal relics is usually determined by the corrosion rate of the metal but it is difficult to monitor the deterioration of the metal relics directly. A strong relationship exists between indoor exposure, the air quality classification of atmospheric corrosion, and the actual deterioration of metal relics. The copper-silver hanging plate method requires a long period of environmental exposure and has certain hysteresis, thus reflecting the current environmental quality of the museum in real time poses some difficulties. However, the application of the environmental reactivity monitor (ERMs) based on the piezoelectric effect can solve the above problems. The invented quartz crystal microbalance (QCM) reactivity monitoring device is applied to study the influence of temperature and humidity on the corrosion of the bronze-simulated materials and the relationship between the corrosion depth rate of the bronze-simulated materials and the frequency change of the crystal oscillator. Then, the recommended classification range of temperature and humidity and the airquality classification standards for the preservation environment of the bronze cultural relics in museums are proposed.
Źródło:
Environment Protection Engineering; 2023, 49, 4; 45--59
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of air quality on sleep and cognitive performance in school children aged 10–12 years: a double-blinded, placebo-controlled, crossover trial
Autorzy:
Klausen, Frida B.
Amidi, Ali
Kjærgaard, Søren K.
Schlünssen, Vivi
Ravn, Peter
Østergaard, Kirsten
Gutzke, Vibeke H.
Glasius, Marianne
Grønborg, Therese K.
Hansen, Stefan N.
Zachariae, Robert
Wargocki, Pawel
Sigsgaard, Torben
Powiązania:
https://bibliotekanauki.pl/articles/2203016.pdf
Data publikacji:
2023-05-23
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
sleep quality
cognition
indoor air
CO2 exposure
school children
RCT study
Opis:
Objectives To investigate the effect of CO₂ during sleep on next-morning cognitive performance in young schoolchildren, the authors performed a double-blind fully balanced crossover placebo-controlled study. Material and Methods The authors included 36 children aged 10–12 years in the climate chamber. The children slept at 21°C in 6 groups each at 3 different conditions separated by 7 days in a random order. Conditions were as follows: high ventilation with CO₂ at 700 ppm, high ventilation with added pure CO₂ at 2000–3000 ppm, and reduced ventilation with CO₂ at 2–3000 ppm and bioeffluents. Children were subjected to a digital cognitive test battery (CANTAB) in the evening prior to sleep and on the next morning after breakfast. Sleep quality was monitored with wrist actigraphs. Results There were no significant exposure effects on cognitive performance. Sleep efficiency was significantly lower at high ventilation with CO₂ at 700 ppm which is considered to be a chance effect. No other effects were seen, and no relation between air quality during sleep and next-morning cognitive performance was observed in the children emitting an estimated 10 l CO₂ /h per child. Conclusions No effect of CO₂ during sleep was found on next day cognition. The children were awakened in the morning, and spent from 45–70 min in well-ventilated rooms before they were tested. Hence, it cannot be precluded that the children have benefitted from the good indoor air quality conditions before and during the testing period. The slightly better sleep efficiency during high CO₂ concentrations might be a chance finding. Hence, replication is needed in actual bedrooms controlling for other external factors before any generalizations can be made.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2023, 36, 2; 177-191
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Errata do artykułu „Przydatność optycznego miernika do oceny narażenia ludzi na drobny pył zawarty w powietrzu pomieszczeń” (MED. PR. 2019;70(2):213–220)
Erratum to the article “The usefulness of an optical monitor for the assessment of human exposure to fine dust in indoor air” (MED PR. 2019;70(2):213–20)
Autorzy:
Kowalska, Małgorzata
Mainka, Anna
Mucha, Walter
Powiązania:
https://bibliotekanauki.pl/articles/2152938.pdf
Data publikacji:
2022
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Opis:
Oryginalna wersja artykułu jest dostępna pod adresem: https://doi.org/10.13075/mp.5893.00780.
The original version of the article can be found at: https://doi.org/10.13075/mp.5893.00780.
Źródło:
Medycyna Pracy; 2022, 73, 5; 434
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acute lead poisoning in an indoor firing range
Autorzy:
Štěpánek, Ladislav
Nakládalová, Marie
Klementa, Viktor
Ferenčíková, Veronika
Powiązania:
https://bibliotekanauki.pl/articles/2085522.pdf
Data publikacji:
2020-05-15
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
lead poisoning
blood lead level
occupational exposure to lead
urine lead level
anemia
chelation therapy
Opis:
The presented case demonstrates that acute lead poisoning may occur due to just short-term exposure to a mixture of lead-containing dust and ammunition. Such exposure may result in high blood lead levels persisting for years in the absence of any symptoms. A middle-aged male with a history of an approximately 7-day cleanup of an old recreational firing range with large ammunition and dust deposits presented to an emergency department with abdominal pain, dyspnea, fatigue and impaired cognitive function. Given his occupational history, specific tests were performed that showed high lead concentrations in both blood and urine. The patient was diagnosed with acute lead poisoning. He was started on chelation therapy that improved both clinical and laboratory parameters. Over a subsequent nearly 3-year follow-up, the patient’s blood lead levels fluctuated and continued to be increased. Given the absence of other sources of lead exposure, these were likely due to the formation of bone deposits. Med Pr. 2020;71(3):375–9
Źródło:
Medycyna Pracy; 2020, 71, 3; 375-379
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combined analysis of onco-epidemiological studies of the relationship between lung cancer and indoor radon exposure
Autorzy:
Yarmoshenko, Ilia V.
Malinovsky, Georgy P.
Powiązania:
https://bibliotekanauki.pl/articles/146354.pdf
Data publikacji:
2020
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
lung cancer
radon
relative risk
Opis:
Objectives: Recent results of epidemiological and medical statistics studies of lung cancer and indoor radon in different regions of the world make a relevant new combined analysis of residential exposure health effects. In particular, new data were obtained by means of a meta-analysis of case-control studies as well as taking into account a confounding effect of human papillomavirus infection in studies of geographically aggregated data. Materials and methods: Two sources of epidemiological data are considered: (1) studies of ecological design and (2) case-control studies. Ecological studies included the analysis performed for the USA counties and Russian oblasts with adjusting for the main confounders. Data on the case-control studies were gained from the meta-analysis of 31 individual studies with a weighting of obtained odds ratios according to the quality of radon exposure reconstruction and size of the reference group. Estimations of lung cancer excess relative risk (ERR) associated with indoor radon exposure are combined. Results: Two types of epidemiological study design provided generally consistent EER estimations. The combined value of ERR due to radon exposure is 0.14 (90% CI: 0.10–0.18) per 100 Bq/m3 . Conclusion: Available geographically aggregated data in regions of Russia and the United States and the meta-analysis of case-control studies conducted in a large number of countries confirm the association of lung cancer with indoor radon exposure.
Źródło:
Nukleonika; 2020, 65, 2; 83-88
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przydatność optycznego miernika do oceny narażenia ludzi na drobny pył zawarty w powietrzu pomieszczeń
The usefulness of an optical monitor for the assessment of human exposure to fine dust in indoor air
Autorzy:
Kowalska, Małgorzata
Mainka, Anna
Mucha, Walter
Powiązania:
https://bibliotekanauki.pl/articles/2164011.pdf
Data publikacji:
2019-04-19
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
zdrowie publiczne
kalibracja
drobny pył PM2,5
powietrze wewnętrzne
narażenie indywidualne
pomiar optyczny
public health
calibration
PM2.5 fine dust
indoor air
personal exposure
optical measurement
Opis:
Wstęp Istotną kwestią w ocenie ryzyka zdrowotnego jest pomiar indywidualnego narażenia, także dla zanieczyszczenia powietrza atmosferycznego drobnym pyłem. Takie możliwości dają stosunkowo proste w obsłudze mierniki optyczne. Celem pracy była ocena możliwości wykorzystywania optycznego miernika AM520 do pomiaru indywidualnego narażenia ludzi na drobny pył PM2,5 i PM10, zawarty w pomieszczeniach zamkniętych, poprzez ustalenie współczynnika kalibracji i ocenę zgodności pomiaru z metodą referencyjną. Materiał i metody W ramach badań wykonano pomiary stężeń pyłu PM2,5 i PM10 w pomieszczeniach (3 lokalizacje w powiecie gliwickim, marzec−maj 2017 r.) z wykorzystaniem aspiratora osobistego SidePak model AM520, a także z użyciem urządzenia referencyjnego LVS3D metodą grawimetryczną. Ustalono wartość współczynnika kalibracji dla optycznego miernika i zgodność pomiarów wykonanych obydwiema metodami. Wyniki Zakres wartości fotometrycznego współczynnika kalibracji kształtował się na poziomie 0,33–0,40 i był zbieżny z wartością 0,38 zalecaną przez producenta. Współczynnik determinacji dla zależności wyników uzyskanych metodą optyczną oraz grawimetryczną był bardzo wysoki i wynosił R2 = 0,91. Wnioski Prezentowane wyniki są obiecujące i pozwalają stwierdzić, że optyczny miernik AM520 może być wykorzystywany do oceny indywidualnego narażenia na drobne pyły PM2,5 i PM10 w pomieszczeniach zamkniętych. Med. Pr. 2019;70(2):213–220
Background An important issue in the assessment of health risks related to air pollution with fine dust is the measurement of individual exposure. Such possibilities are provided by relatively easy to use optical monitors. The aim of the presented work was to assess the possibility of using the AM520 optical monitor to measure individual human exposure to PM2.5 and PM10 indoors by determining the calibration factor and assessing the compliance of the measurement with the reference method. Material and Methods As part of the research, indoor concentrations of PM2.5 and PM10 and were measured (3 locations in the Gliwice Poviat, March−May 2017) with the use of the SidePak Personal Aerosol Monitor AM520, as well as the reference LVS3D device by means of the gravimetric method. The value of the calibration coefficient for the optical monitor was determined, and the consistency of measurements performed with both methods was assessed. Results The photometric calibration factor ranged 0.33−0.40 and was concurrent with the 0.38 value recommended by the manufacturer. The determination coefficient for the correlation between the measurement results obtained with the optical and gravimetric methods was very high (R2 = 0.91). Conclusions The presented results are promising and allow for the conclusion that the AM520 optical monitor can be used to assess individual exposure to PM2.5 and PM10 indoors. Med Pr. 2019;70(2):213–20
Źródło:
Medycyna Pracy; 2019, 70, 2; 213-220
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Promieniowanie nadfioletowe solariów jako potencjalne źródło zagrożeń zdrowotnych – podstawowa wiedza dla użytkowników, lekarzy i personelu solariów o prawidłowym korzystaniu z tych urządzeń
Ultraviolet exposure from indoor tanning devices as a potential source of health risks: Basic knowledge of the proper use of these devices for practical users, physicians and solarium staff
Autorzy:
Malinowska-Borowska, Jolanta
Janosik, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/2164052.pdf
Data publikacji:
2017-07-26
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
profilaktyka
promieniowanie UV
rak skóry
solarium
natężenie napromienienia
nadfiolet
prevention
UV radiation
skin cancer
tanning beds
maximum value of UV irradiance
ultraviolet radiation
Opis:
Z uwagi na udowodniony szkodliwy wpływ promieniowania nadfioletowego (UV) emitowanego przez solaria na zdrowie opalających się – w szczególności możliwość wywoływania nowotworów skóry – istnieje potrzeba wprowadzenia w Polsce regulacji prawnych, które określałyby zasady funkcjonowania salonów oferujących usługi opalania sztucznym promieniowaniem UV, i ustanowienia zasad nadzoru nad parametrami technicznymi urządzeń opalających, właściwym ich serwisowaniem, merytorycznym przygotowaniem osób obsługujących lampy i innymi aspektami bezpieczeństwa stosowania tych lamp. W artykule przybliżono mechanizm szkodliwego oddziaływania promieniowania nadfioletowego na organizm człowieka, skalę narażenia wynikającego z nadmiernego opalania się i wskazano metody szacowania wielkości ekspozycji na UV oraz możliwe działania ograniczające nadmierną ekspozycję, a tym samym zapobiegające powstawaniu chorób skóry wywoływanych nadfioletem. Med. Pr. 2017;68(5):653–665
Bearing in mind the adverse health effects of exposure to ultraviolet (UV) radiation in solarium, especially the risk of carcinogenesis, there is a need to adopt legal regulations by relevant Polish authorities. They should set out the principles for indoor tanning studios operation, supervision and service of the technical parameters of tanning devices and training programs to provide the staff with professional knowledge and other aspects of safety in these facilities. The mechanism of the harmful effects of ultraviolet radiation on the human body, scale of overexposure, resulting from excessive sunbathing are described. Methods for estimating UV exposure and possible actions aimed at reducing the overexposure and preventing from cancer development caused by UV are also presented in this paper. Med Pr 2017;68(5):653–665
Źródło:
Medycyna Pracy; 2017, 68, 5; 653-665
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure of the Driver Staying Inside the Car Cabin to Volatile Organic Compounds
Ekspozycja kierowcy przebywającego wewnątrz kabiny nowego pojazdu na lotne związki organiczne
Autorzy:
Janicka, A.
Michniewicz, D.
Skrętowicz, M.
Trzmiel, K.
Wróbel, R.
Zawiślak, M.
Powiązania:
https://bibliotekanauki.pl/articles/389554.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
car vehicle interior
indoor air quality
volatile organic compounds
wnętrze kabiny pojazdu
jakość powietrza wewnętrznego
lotne związki organiczne
Opis:
Nowadays the motorization is one of the basic branch of industry. Dynamic development of the – transportation sector has very positive impact on the social and civilization benefits, but on the other side, it generates also a lot of problems, especially related to the people health and life. The road transport is one of the main air pollution source, particularly in the cities. Furthermore, the motorization development caused increased in residence time inside vehicles. In the cities the traffic intensity is significantly higher than in the rural areas. This is the reason why road congestions are created. Exhausts, including hazardous volatile organic compounds, can easily penetrate into the cabin in the road congestion situation and they are the serious danger to the drivers and passengers. In the new cars, additional sources of volatile organic compounds are elements of the cabin interior. In this paper the results of the research on volatile organic compounds concentration inside passenger car in simulated conditions were presented. Additionally, the main sources of volatile organic compounds inside the car cabin were identify and the evaluation of driver exposure was defined.
W obecnych czasach motoryzacja stanowi jedną z głównych gałęzi przemysłowych. Dynamiczny rozwój motoryzacji, poza wieloma walorami społecznymi i cywilizacyjnymi, jest powodem licznych problemów, przekładających się w mniejszym lub większym stopniu na zdrowie i życie ludzi. Transport jest jednym z głównych źródeł emisji zanieczyszczeń do powietrza, szczególnie w aglomeracjach miejskich. Co więcej, rozwój motoryzacji sprawia również, że ludzie spędzają w samochodach coraz więcej czasu. W warunkach miejskich natężenie ruchu jest znacznie wyższe niż poza miastem. Często powstają zatory drogowe. Spaliny, których składnikami są również lotne związki organiczne, dostając się do wnętrza pojazdów uczestniczących w zatorze drogowym, stanowią poważne zagrożenie dla kierowców tych pojazdów oraz ich pasażerów. W nowych pojazdach dodatkowym źródłem lotnych związków organicznych mogą być elementy wyposażenia wnętrza kabiny. W pracy przedstawiono wyniki badań stężeń lotnych związków organicznych wewnątrz kabiny nowego, eksploatowanego samochodu osobowego. Zidentyfikowano również źródła lotnych związków organicznych znajdujących się wewnątrz pojazdu oraz dokonano oceny narażenia kierowcy.
Źródło:
Ecological Chemistry and Engineering. A; 2016, 23, 2; 139-145
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Źródła narażenia użytkowników pojazdów na lotne związki organiczne
The sources of exposure of vehicle users on volatile organic compound
Autorzy:
Faber, J.
Brodzik, K.
Powiązania:
https://bibliotekanauki.pl/articles/316068.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
zanieczyszczenie powietrza
lotne związki organiczne
LZO
stężenie zanieczyszczeń
jakość powietrza
powietrze wewnętrzne
wnętrze pojazdu
kabina samochodu
air pollution
volatile organic compounds
VOC
concentration of pollutants
car cabin
air quality
indoor air
Opis:
W artykule omówiono źródła obecności lotnych związków organicznych, będących głównymi zanieczyszczeniami powietrza w kabinach samochodów. Na podstawie przeglądu literatury przedstawiono typowe stężenia tych zanieczyszczeń w samochodach nowych i będących w trakcie eksploatacji. Stwierdzono, że głównymi zanieczyszczeniami w kabinach nowych samochodów są węglowodory alifatyczne (undekan, dodekan, tridekan), węglowodory aromatyczne (toluen, styren, fenol) i inne. W samochodach eksploatowanych badano głównie zawartość benzenu, toluenu, etylobenzenu i izomerów ksylenu, których stężenia kształtowały się od 2 do około 800 µg/m3. W artykule omówiono wpływ zanieczyszczeń powietrza we wnętrzach pojazdów na zdrowie ludzi oraz wpływ rodzaju materiałów i zmiany elementów wyposażenia na aktualne stężenie związków organicznych w kabinie. Przedstawiono stężenia różnych węglowodorów we wnętrzach pojazdów produkowanych w Polsce, mierzonych bezpośrednio po opuszczeniu przez samochód linii produkcyjnej. Stwierdzono, że całkowite stężenie sumy lotnych związków organicznych kształtowało się w zakresie od około 800 µg/m³ do około 8000 µg/m³ i było silnie zależne od zastosowanych materiałów wyposażenia kabiny
The paper discussed the sources of volatile organic compounds presence, which are the main air pollutants in vehicles’ cabins. Typical concentrations of these pollutants in new and used vehicles are presented on the basis of literature review. It was found that the main pollutants in new vehicles’ cabins are aliphatic hydrocarbons (undecane, dodecane, tridecane), aromatic hydrocarbons (toluene, styrene, phenol) and others. In used vehicles the content of benzene, toluene, ethylbenzene and xylene isomers was mainly under study, and their concentrations ranged between 2 and 800 µg/m³. In the paper the influence of interior air pollutants on human health was discussed and the influence of type of materials used and change of interior elements on actual concentration of organic compounds in vehicle’s cabin. Concentrations of different hydrocarbons which were measured directly after vehicle left the production line, in interiors of vehicles’ produced in Poland, are presented. It was stated, that total concentration of volatile organic compounds ranged between circa 800 µg/m³ to circa 8000 µg/m³ and was strongly influenced by the materials used to equip car cabin
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 6; 160-167
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of exposure to fungi in the heavily contaminated work environment (a solid waste sorting plant) based on the ergosterol analysis
Autorzy:
Kozajda, Anna I.
Jeżak, Karolina
Sowiak, Małgorzata
Gutarowska, Beata
Szadkowska-Stańczyk, Irena
Powiązania:
https://bibliotekanauki.pl/articles/2177184.pdf
Data publikacji:
2015-07-17
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational exposure
bioaerosols
sterols
solid waste management plant
ergosterol
indoor air pollution
Opis:
Objectives This paper reports on the results of the study aimed at application of ergosterol as an quantitative indicator of fungal bioaerosol present in the indoor air in occupational environment heavily contaminated with organic dust as well as its comparison with the culturable method. Material and Methods The study was conducted in the indoor solid waste sorting plant. Using Andersen impactor adapted to 1 plate at the flow rate of 30 l/min, indoor air was sampled in the workers’ breathing zone. Ergosterol was sampled using gelatinous filter (1000 l of air) and then analyzed by means of the spectrophotometric method. Fungi were sampled on malt extract agar (MEA) medium (3 replications: 2 l, 7.5 l, 15 l of air) and analyzed by means of the culturable method. Based on ergosterol analyzes, concentration of fungi was calculated. Results were given as the range assuming min. as 5.1 pg ergosterol/spore and max as 1.7 pg ergosterol/spore. Results The average concentrations of ergosterol in a working room (arithmetic mean (AM), standard deviation (SD); minimum–maximum (min.–max)) were, respectively: 2.16, 0.72; 0.85–2.92 μg/m³; fungi calculated based on ergosterol – 424.1×10³–1272.4×10³, 140.1×10³– 420.4×10³, 167×10³–1716.5×10³ CFU/m³, and culturable fungi – 13×10³, 9.7×10³, 1.9×10³–34×10³ CFU/m³). It was revealed that concentrations of calculated fungi were even 2 orders of magnitude higher than culturable fungi. Conclusions The quantitative assessment of moldiness by means of ergosterol measurement seems to be a reliable indicator for environments heavily contaminated with organic dust, where viable and non-viable fungi are present in high proportions. Based on that result, more restrictive (as compared to a similar assessment carried out by means of the culturable method) hygienic recommendations, especially those related to the use of preventive measures protecting the employees’ respiratory tract, should have been undertaken.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2015, 28, 5; 813-821
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie zanieczyszczeń powietrza oddziałujących na dzieci w przedszkolu miejskim zlokalizowanym przy drodze o dużym natężeniu ruchu
Children exposure to air pollutants in nursery school near a major road in urban area
Autorzy:
Mainka, A.
Zajusz-Zubek, E.
Kozielska, B.
Brągoszewska, E.
Powiązania:
https://bibliotekanauki.pl/articles/297242.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
powietrze wewnętrzne
lotne związki organiczne
pył zawieszony
bioaerozol
dwutlenek węgla
indoor air
children
volatile organic compounds
particulate matter
bioaerosols
carbon dioxide
Opis:
Przedstawiono wyniki pomiarów stężeń lotnych związków organicznych (LZO), pyłu całkowitego (TSP), frakcji PM10, PM2,5 i PM1 oraz bioaerozoli. Wykonywano również pomiary stężenia CO2 jako wskaźnika skuteczności systemu wentylacji. Pomiary przeprowadzono w okresie grzewczym w dwóch salach opiekuńczych (dzieci w wieku 3-6 lat) oraz na zewnątrz budynku przedszkola położonego w centrum Gliwic (Górny Śląsk) przy drodze o dużym natężeniu ruchu. Wyniki badań wskazują na gorsze warunki co do jakości powietrza wewnątrz. Dla sumy 16 LZO stosunki stężeń wewnątrz i na zewnątrz budynku (I/O) w zależności od sali wahały się od 2 do 5, dla pyłu PM10 sięgały 4, a dla PM2,5 wynosiły około 2. W przypadku bioaerozoli grzybowych średni wskaźnik I/O sięgał 2, natomiast dla aerozoli bakteryjnych przekraczał 8. Jednocześnie ciągłe pomiary stężeń CO2 wykazały dominujący udział niskiej jakości powietrza podczas przebywania dzieci w obu salach przedszkola. Wyniki wskazują na niewystarczającą skuteczność systemu wentylacji, co może negatywnie wpływać na zdrowie i samopoczucie dzieci.
Children are particularly sensitive to pollutants. The reason for this is that, according to body weight, they breathe in more air than adults. Moreover, due to rapid growth, their immature immune system is more vulnerable to damage than already mature organisms. Children aged 3 to 6 spend large amounts of time indoors, so there is a necessity to evaluate the quality of air in nursery schools. This study investigated the concentrations of volatile organic compounds (VOCs), particulate matter (TSP, PM10, PM2.5 and PM1) and bioaerosols. The concentration of CO2 was monitored as the indicator of ventilation efficiency. The measurements were performed during winter, in two classrooms and outside the nursery school building located in the centre of Gliwice (Upper Silesia), near a road with high traffic. Outdoor concentrations were lower than those indoors for each inspected classroom. For the sum of 16 VOCs, the I/O ratio, depending on classroom, varied from 2 to 5, PM10 reached 4 and for PM2.5, the ratio was about 2. For fungi bioaerosols, the average I/O ratio was about 2, while for bacteria, aerosols exceeded 8. The evaluation of indoor air quality (IAQ) based on CO2 concentration differed from averaging time. Taking into consideration the 24 hour distribution of CO2 concentration in both classrooms dominated the first category of indoor air quality (WEW1), we can expect that children stayed in the environment with high air quality, however, this was not the case. During children’s nursery school attendance for the duration of the working day and throughout five-hour elementary nursery care, the air inside classrooms was mostly 65 to 72% of poor quality (WEW4). In the case of certain pollutants, significant differences in air quality were found between the classrooms of older (I) and younger (II) children. For fungal bioaerosols, the concentration was twice as high in the classroom of younger children (II) compared to the classroom of older children (I). However, in the case of particulate matter, for all studied fractions (TSP, PM10, PM2.5 and PM1), concentrations were about twice as high in classroom I compared to classroom II. This confirms the important role of particulate matter resuspension in classroom I as a result of the intensive activity of older children. Compared to the classroom of older children (I), in the classroom of younger children (II) there were more absorbent materials; hence, we expected higher concentrations of VOCs associated with secondary sources. However, concentrations of VOCs did not confirm this relationship. In the case of bacterial bioaerosols, no significant differences were observed between the classrooms. Continuous measurements of CO2 concentrations showed that in the classroom of older children (I), the air was negligibly worse than in the classroom of younger children (II); this may have been due to the lower efficiency of the natural ventilation system on the first floor of the investigated building.
Źródło:
Inżynieria i Ochrona Środowiska; 2015, 18, 1; 119-133
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of exposure to electromagnetic radiofrequency radiation in the indoor workplace accessible to the public by the use of frequency-selective exposimeters
Autorzy:
Gryz, Krzysztof
Karpowicz, Jolanta
Leszko, Wiesław
Zradziński, Patryk
Powiązania:
https://bibliotekanauki.pl/articles/2179019.pdf
Data publikacji:
2014-12-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational exposure
measurements
electromagnetic fields
exposure pattern
Opis:
Objectives: The aim of the study was to identify and assess electromagnetic radiofrequency radiation (EMRR) exposure in a workplace located in a publicly accessible environment, and represented by offices (where exposure is caused by various transmitters of local fixed indoor and outdoor wireless communication systems). Material and Methods: The investigations were performed in 45 buildings (in urban and rural areas in various regions of Poland), using frequency-selective electric field strength (E-field) exposimeters sensitive to the EMRR with a frequency range of 88–2500 MHz, split into 12 subbands corresponding to the operating frequencies of typical EMRR sources. The variability of the E-field was analyzed for each frequency range and the total level of exposure by statistical parameters of recorded exposimetric profiles: minimum, maximum, median values and 25–75th – percentiles. Results: The main sources of exposure to EMRR are mobile phone base transceiver stations (BTS) and radio-television transmitters (RTV). The frequency composition in a particular office depends on the building’s location. The E-field recorded in buildings in urban and rural areas from the outdoor BTS did not exceed respectively: medians – 0.19 and 0.05 V/m, 75th percentiles – 0.25 and 0.09 V/m. In buildings equipped with the indoor BTS antennas the E-field did not exceed: medians – 1 V/m, 75th percentiles – 1.8 V/m. Whereas in urban and rural areas, the median and 75th percentile values of the E-field recorded in buildings located near the RTV (within 1 km) did not exceed: 1.5 and 3.8 V/m or 0.4 and 0.8 V/m, for radio FM band or for TV bands, respectively. Conclusions: Investigations confirmed the practical applicability of the exposimetric measurements technique for evaluating parameters of worker’s exposure in both frequency- and time-domain. The presented results show EMRR exposure of workers or general public in locations comparable to offices to be well below international limits.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2014, 27, 6; 1043-1054
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance evaluation of strip parquet flooring panels after long-term, in-service exposure
Autorzy:
Nemeth, R.
Molnarne Posh, P.
Molnar, S.
Bak, M.
Powiązania:
https://bibliotekanauki.pl/articles/52744.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Drewna
Tematy:
performance
strip parquet flooring
black locust
steaming
panel
long-term exposure
abrasion resistance
indoor service test
dimensional stabilization
Opis:
Due to its extraordinary hardness, decorative appearance and possible small dimensions, black locust wood is assumed to be an excellent material for strip parquetflooring. The favourable colour changes achieved by controlled steam treatment further increased the utilization potential of this material. Flooring was installed on a student dormitory stair landing in heavy use. Due to the flooring’s very high exposure, 5 years was considered a long enough period to compare the different face layer materials during in-service test. Oil was used as a coating to avoid the remarkable protecting effect of hard film-forming varnishes (acrylic, etc.) against abrasion. Besides the flooring turning grey (all face layers no matter what treatment), only some delamination occurred at certain places after five years in service.The laboratory test results for abrasion resistance, dimensional changes and deformation were analysed. Additionally, the Brinell-Mörath hardness after indoor service and the abrasion due to indoor service were analysed. In terms of abrasion resistance, dimensional changes and deformation, no essential differences werefound between the oil-treated and untreated black locust wood on the one hand, and the control oak specimen on the other. Long-term tests showed that, after 5 years in service, the Brinell-Mörath-hardness decreased considerably for all the testedmaterials. The type of section and the presence of wide rays influenced the roughness and the waviness of the surface after indoor service.
Źródło:
Drewno. Prace Naukowe. Doniesienia. Komunikaty; 2014, 57, 193
1644-3985
Pojawia się w:
Drewno. Prace Naukowe. Doniesienia. Komunikaty
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor allergens in settled dust from kindergartens in city of Łódź, Poland
Autorzy:
Cyprowski, Marcin
Buczyńska, Alina
Szadkowska-Stańczyk, Irena
Powiązania:
https://bibliotekanauki.pl/articles/2179064.pdf
Data publikacji:
2013-12-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
indoor allergens
settled dust
environmental exposure
allergen transportation
kindergartens
children
Opis:
Objectives: The main objective of the study was to determine the levels of house dust mite (Der p1), dog (Can f1), cat (Fel d1) and cockroach (Bla g2) allergens in kindergartens localized in an urban agglomeration. Material and Methods: A quantitative analysis of allergens was carried out in settled dust samples collected by vacuuming the floor surface in three kindergartens (N = 84) and children's clothing (N = 36). The samples were collected in springsummer and autumn-winter periods as well as at the beginning and end of the week. The allergen dust concentration was determined by enzyme-linked immunoenzymatic assay (ELISA). Results: The mean geometric concentrations (±geometric standard deviations) of allergens Der p1, Can f1, Fel d1 and Bla g2 determined in kindergartens were: 0.02±3.21 μg/g of dust; 0.97±4.49 μg/g of dust; 0.30±4.43 μg/g of dust and 0.01±3.08 μg/g of dust, respectively. Younger classrooms (children aged from 3 to 4 years) were characterized by almost twice higher mean concentration of allergen Fel d1, as compared to older classrooms (children aged from 5 to 6 years) (p < 0.05). A significant impact of seasonality on the level of dog allergen Can f1 was found (p < 0.05). No significant weekly variation was found in average concentrations of the allergens. Children who had a dog and/or cat at home were characterized by high concentrations of allergens Can f1 and Fel d1 on their clothes (59.2±5.39 μg Can f1/g of dust; 3.63±1.47 μg Fel d1/g of dust), significantly higher than concentrations of allergens in children who did not have any pets (p < 0.001). Conclusions: Special attention should be paid to keeping the kindergarten rooms tidy and clean and to an appropriate choice of furnishings and fittings which would prevent the proliferation of the house dust mite and accumulation of allergens.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2013, 26, 6; 890-899
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variations in particle concentrations and indoor air parameters in classrooms in the heating and summer seasons
Zmiany koncentracji cząstek i parametrów powietrza wewnętrznego w klasach w sezonie grzewczym i letnim
Autorzy:
Połednik, B.
Powiązania:
https://bibliotekanauki.pl/articles/204722.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
classroom
particle mass concentration
particle number concentration
student exposure
indoor air parameters
klasa
koncentracja cząstek
masowa koncentracja cząstek
ilościowa koncentracja cząstek
ekspozycja uczniów
parametry powietrza wewnętrznego
Opis:
Simultaneous measurements of the indoor and outdoor particle mass (PM) and particle number (PN) concentrations as well as the air temperature, relative humidity (RH), and CO2 concentrations have been conducted in 6 occupied (L) and unoccupied (V) classrooms in 3 secondary schools in Lublin, Poland, in the heating (H) and summer (S) seasons. The schools were located in residential areas where the majority of private houses are heated by means of coal-burning stoves. The ratios of the average particle concentrations in occupied and unoccupied classrooms (L/V) were higher during the heating season measurements. The ratios of the average particle concentrations during the measurements in the heating and summer seasons (H/S) were higher in occupied classrooms. In both seasons the average PM and PN concentrations amounted to 239 μg/m3 and 7.4×103/cm3in the occupied classrooms, and to 76 μg/m3 and 5.4×103cm3 in the unoccupied classrooms, respectively. The particle exposures experienced by students were higher in the monitored classrooms than outdoors and were on average about 50% higher in the heating than in the summer season. A positive correlation between mass concentrations of coarse particles and indoor air temperature, RH and CO2 concentrations in both seasons was observed. The concentrations of fine particles were negatively correlated with the indoor air parameters in the heating season, and positively correlated in the summer season.
Pomiary masowych (PM) i ilościowych (PN) koncentracji cząstek, jak również temperatury, wilgotności względnej (RH) i stężenia CO2 przeprowadzono w 3 gimnazjalnych szkołach w Lublinie w sezonie grzewczym (H) i letnim (S). Szkoły były zlokalizowane w dzielnicach, w których większość prywatnych domów ogrzewana jest piecami węglowymi. W każdej ze szkół wybrano 2 klasy, w których wykonano pomiary przy obecności (L) i nieobecności (V) uczniów. Równoległe pomiary przeprowadzono dla powietrza zewnętrznego. Stosunki średnich koncentracji cząstek w klasach z uczniami i bez uczniów (L/V) były większe w sezonie grzewczym. Stosunki średnich koncentracji cząstek podczas pomiarów w sezonie grzewczym i letnim (H/S) były większe w klasach z uczniami. W obydwu sezonach średnie koncentracje PM i PN w klasach z uczniami wynosiły odpowiednio 239 μg/m3 i 7,4×103/cm3, a w klasach bez uczniów 76 μg/m3 i 5,4×103cm3. Ekspozycje uczniów w klasach były wyższe niż na zewnątrz i były średnio o ok. 50% większe w sezonie grzewczym. W obydwu sezonach zaobserwowano dodatnią korelację pomiędzy masową koncentracją grubych cząstek a temperaturą, RH i stężeniem CO2 w powietrzu wewnętrznym. Koncentracje drobnych cząstek były ujemnie skorelowane z parametrami powietrza wewnętrznego w sezonie grzewczym i dodatnio w sezonie letnim.
Źródło:
Archives of Environmental Protection; 2013, 39, 4; 15-28
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies