Tytuł:
Indoor air particles in office buildings with suspected indoor air problems in the Helsinki area
Autorzy:
Lappalainen, Sanna
Salonen, Heidi
Salmi, Kari
Reijula, Kari
Powiązania:
https://bibliotekanauki.pl/articles/2179800.pdf
Data publikacji:
2013-03-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
particle counts
indoor air
supply air
office
health effects
Opis:
Objectives: Airborne particle concentrations can be used as quality indicators of indoor environments. The previous lack of reference data has limited the use of particle measurements in offi ce environments. The aim of this study was to describe the concentrations of airborne particles (≥ 0.5 μm and ≥ 5.0 μm) in 122 Finnish offi ce buildings with suspected indoor air problems. Materials and Methods: The database consisted of indoor air and supply air particle samples collected in 2001–2006 from the Helsinki area. The particle concentrations (≥ 0.5 μm and ≥ 5.0 μm) were measured in the indoor air (528 samples from 122 offi ce rooms) and in the supply air (384 samples from 105 offi ce rooms) with an optical particle counter. Airborne particle concentrations ≥ 0.5 μm were categorized according to the effi ciency of supply air fi ltration and health survey data. Results: The mean concentrations in the indoor air equaled 1900 particles/l and in the supply air 1300 particles/l. The effi ciency of supply air fi ltration decreased the fi ne particles counts in both the indoor and supply air. The counts of large particles, ≥ 5.0 μm, were low in the indoor air. Airborne counts of ≥ 0.5 μm particles (geometric mean) were statistically higher in the offi ces whose occupants had work-related symptoms (eye and/or upper respiratory symptoms or upper respiratory infections) than in the offi ces whose occupants had no such symptoms. However, the symptoms may also be linked to other indoor air problems or particle characteristics not studied in this work. Conclusions: This study indicates typical airborne particle levels (≥ 0.5 μm and ≥ 5.0 μm) in Finnish offi ce buildings with suspected indoor air problems. The results can be used to evaluate the quality of indoor environment, possible indoor air problems, and the need for additional investigations.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2013, 26, 1; 155-164
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Survey of indoor air pollution and health symptoms at residential buildings
Autorzy:
Sarkar, S.
Nandy, A.
Talapatra, S.N.
Basu, R.
Mukhopadhyay, A.
Powiązania:
https://bibliotekanauki.pl/articles/11531.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
indoor air
air pollution
air pollutant
household product
human health
hazard symptom
residential building
Opis:
This survey work summarizes the generation of indoor air pollutants (IAPs) through household products and activities and also the probable health symptoms of IAPs were discussed through questionnaire in the residential buildings of urban and semi urban area when compared to rural (control) area by door to door survey. The IAPs are categorized as physical, chemical and biological and surveyed as per the product(s) usage in the closed room of buildings. The survey results of IAPs generated from household products and activities, these are asbestos, fine particulate matters and ash as physical pollutants. The chemical pollutants are carbon mono and di oxide gases, phthalates; DDT, chlordane, heptachlor, o-phenylphenol; PBDEs, Formaldehyde, Other Aldehydes, lead, benzene, chloroform, para-dichlorobenzene, methylene chloride, perchloroethylene, styrene, benzene, formaldehyde, terpenes, styrene, phthalate esters, toluene, Propellant, pesticides, PAH, NOx, acrylamide, VOCs, acetone, HCl gas and biological pollutants are bacteria, fungi, viruses, house dust mites, animal dander; cockroaches, microbial spore. In respect to established health impact data, the health symptoms were recorded after survey in two areas viz. urban and semi urban area. The health symptoms were recorded as eye, nose, and throat irritation; allergic reactions, respiratory irritation, aggravated asthma, influenza and other infectious diseases may be the generation of IAPs. The urban and semi urban area are compared with rural (control) area in which no symptoms were found as per discussion. In the present survey it was concluded that the generation of IAPs may from household products and activities in the urban and semi urban area due to less ventilation facilities when compared to rural (control) area. This is a preliminary observation, further researches are needed in relation to measurement of physical, chemical and biological indoor pollutants in closed room of residential buildings and also health hazards study of residents by haematological, biochemical, enzymological and genotoxicological parameters.
Źródło:
International Letters of Natural Sciences; 2014, 08, 1
2300-9675
Pojawia się w:
International Letters of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studying the parameters of indoor air in premises with infrared heaters
Autorzy:
Spodyniuk, Nadiia
Shelimanova, Olena
Powiązania:
https://bibliotekanauki.pl/articles/2065617.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska
Tematy:
infrared heating
air temperature
working area
ogrzewanie na podczerwień
temperatura powietrza
obszar roboczy
Opis:
The main causes of human heat loss are convection, conduction, radiation and evaporation. Conductive heat loss is so small that it can be considered alongside convective heat loss. The most characteristic factor of heat loss is radiation. As a result of experimental studies, a graph of air temperature in the work area was plotted showing the mobility of air at different heat capacities of the emitter. There was a significant increase in air temperature in the working area during air flows. The research findings can be used to design infrared heating in industrial buildings.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2020, 9, 1; 105--109
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perceived indoor air quality, air-related symptoms and ventilation in Finnish hospitals
Autorzy:
Hellgren, Ulla-Maija
Hyvärinen, Markku
Holopainen, Rauno
Reijula, Kari
Powiązania:
https://bibliotekanauki.pl/articles/2185474.pdf
Data publikacji:
2011-03-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
evaluation of ventilation
Indoor Air Questionnaire
perceived indoor air quality
Health care workers
Opis:
Objectives: Good ventilation is more important in hospitals than in many other buildings. The objective of this study was to evaluate the effect of the condition, performance and modernity of ventilation systems on the perceived indoor air quality (IAQ) and the indoor air-related symptoms of hospital personnel. Materials and Methods: An inspection and evaluation graded on a 1 to 3 scale of the condition, performance, and modernity of the ventilation systems was carried out in ten central hospitals in Finland. The perceived IAQ and the related symptoms were collected by means of an indoor air questionnaire survey among the workers in these hospitals. Results: The condition, performance and modernity of the ventilation systems were good in 40% of the hospitals included in the research and poor in another 40% of them. In hospitals where the majority of the ventilation systems were assessed to be good, the prevalence of the indoor air-related complaints and symptoms was lower than in hospitals where the majority of the ventilation systems were assessed as needing extensive repairs. Conclusions: The condition and performance of the ventilation systems in hospitals had a significant impact on the perceived IAQ and the symptoms observed among the employees in Finnish hospitals. Therefore, it is important that hospital ventilation systems are maintained properly and regularly. Furthermore, they should be renovated, at the latest when their technical lifespan expires.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2011, 24, 1; 48-56
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Photodegradation of Lower Polybrominated Diphenyl Ether Congeners in Indoor Air – Model Studies
Autorzy:
Staszowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/124336.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PBDEs
indoor air quality
flame retardants
photolytic degradation
Opis:
Polybrominated diphenyl ethers (PBDEs) are additive flame retardants which have found applications in polymers for many consumer plastic and electronic goods. Wide use of these chemicals has led to their extremely high concentrations in the indor environments. This paper presents an exploratory study of the photodebromination of five individual lower polybrominated diphenyl ether congeners (BDE-28, BDE-47, BDE-99, BDE-100 and BDE-101) irradiated with white light and different UV (A, B, C) light ranges. The capability of photodegradation of lower PBDEs under room lights was proven by the debromination which occurred with various effectiveness for the selected PBDE congeners and depended of light source. Almost all PBDE congeners showed the greatest decay when exposed to UV-C, with the exception of BDE-100. The decay of irradiated congeners occurred rapidly during the first 5 min of experiment. The final degradation varied from 38% decay (BDE-28, UV-C) to 94% (BDE-47, UV-C). These findings can help in predicting PBDE behavior in indoors and also be useful in the design of PBDE remediation processes.
Źródło:
Journal of Ecological Engineering; 2017, 18, 3; 180-186
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość powietrza w wielorodzinnych budynkach mieszkalnych
Indoor air quality in multifamily buildings
Autorzy:
Telejko, M.
Zender–Świercz, E.
Piotrowski, J.Z.
Powiązania:
https://bibliotekanauki.pl/articles/390643.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
jakość powietrza wewnętrznego
mikroklimat
wymiana powietrza
fizyka budowli
indoor air quality
microclimate
air exchange
building physics
Opis:
Obowiązujące aktualnie przepisy prawne regulujące zagadnienia wentylacji naturalnej [1], [2], [3] w wielu obszarach są niejednoznaczne, a niekiedy wręcz sprzeczne. Sytuacja taka prowadzi do stosowania rozwiązań powodujących poważne zaburzenia w działaniu wentylacji grawitacyjnej. W dużej części budynków zaburzenia te są wynikiem dostarczania do pomieszczeń zbyt małej ilości powietrza zewnętrznego. Jak wykazały badania, ze względu na kształtowanie warunków mikroklimatu wnętrz, podstawowe znaczenie ma nie tylko wielkość dostarczanego strumienia powietrza zewnętrznego, ale również rozmieszczenie elementów doprowadzających to powietrze.
The applicable legislation connected with the natural ventilation are ambiguous and sometimes contradictory. This leads to serious problems with natural ventilation. In most cases malfunction of the natural ventilation is due to the insufficient stream of air from the outside. The research showed that the microclimate is influenced not only by the incoming air stream, but also by the layout of the air supply.
Źródło:
Budownictwo i Architektura; 2013, 12, 3; 67-74
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of indoor air quality in a store with additional gas heater
Autorzy:
Wysocka, Monika
Załuska, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1177489.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
air pollution
carbon dioxide
gas heater
heating
indoor air quality
thermal comfort
ventilation
Opis:
The quality of the internal environment is an extremely important issue, because users of rooms spend a significant part of the day inside buildings. The quality of the environment is largely dependent on the quality of the indoor air. The parameters of the air we breathe affect our health and the comfort of use of the rooms. Poor indoor air quality can cause a decrease in human comfort and various illnesses and ailments. Therefore, care should be taken to ensure adequate ventilation in the rooms, especially those that have an additional source of pollutant emissions. The purpose of this work is to examine the effect of heating a commercial premises room with a gas heater on air quality. The following parameters were measured as part of the tests: carbon dioxide concentration, air temperature and relative air humidity. The most important parameter significantly affecting the deterioration of the quality of the interior microclimate is carbon dioxide, the level of which reached high values, well above the hygienic minimum (1000 ppm). In order to compare the values of the tested parameters, the measurements were carried out in two options - for a period of five days with the stove running and another two days without additional heating.
Źródło:
World Scientific News; 2018, 102; 209-216
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Childrens allergic diseases and microbial contamination of indoor air - a case report
Autorzy:
Kasznia-Kocot, J
Lis, D.O.
Kordys-Darmolinska, B.
Grzybowska-Chlebowczyk, U.
Wos, H.
Gorny, R.L.
Powiązania:
https://bibliotekanauki.pl/articles/51486.pdf
Data publikacji:
2007
Wydawca:
Instytut Medycyny Wsi
Tematy:
human disease
asthma
perennial rhinitis
microbial contamination
indoor air
allergy
child
bacteria
damp house
fungi
allergen
Opis:
The assessment of exposure to bioaerosols in damp houses of two children who suffered from perennial rhinitis and asthma was performed. The paper presents an approach to the complex (i.e., medical and environmental) treatment of allergic diseases.
Źródło:
Annals of Agricultural and Environmental Medicine; 2007, 14, 1
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor air studies of fungi contamination in two kindergartens in Kavala, Greece
Autorzy:
Łukaszuk, C.
Krajewska-Kułak, E.
Chatzopulu, A.
Theodosopoulou, E.
Powiązania:
https://bibliotekanauki.pl/articles/1917817.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Indoor air fungi
kindergartens
SAS Super 100
Opis:
Introduction: Fungi and moulds are biological hazards that are ubiquitous both in the communal and occupational environments. The aim of the study was to assess the presence of airborne fungi in two kindergartens in Kavala, Greece. Materials and methods: Materials for the tests were: the air samples (in front of the buildings and the selected rooms) of the two kindergartens. The first Kavala kindergarten was located atop a hill and the second in the city center. The air pollution was determined using SAS SUPER 100. Results: The mean number of fungal colonies isolated from air of the kindergarten rooms in the city center was 478.3±148.4 CFU/m3. The mean number of fungal colonies isolated from air of the kindergarten on the hill was 343.6±188.8 CFU/m3. Aspergillus niger was most frequently isolated in air samples from the kindergarten rooms in the city center, while Penicillium species predominated the kindergarten rooms on the hill. CFU values in the air samples outside the kindergartens were higher in the center than on the hill of Kavala. CFU values of the examined air samples are varied. In the kindergarten rooms in the center of Kavala the most frequently isolated species was Aspergillus niger, and in the kindergarten on the hill it was Penicillium species. Conclusions: The present study demonstrated considerable numbers of fungi in the air in two kindergartens in Kavala, Greece.
Źródło:
Progress in Health Sciences; 2016, 6(1); 123-129
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor air quality in computer labs
Jakość powietrza wewnętrznego w pracowniach komputerowych
Autorzy:
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/402282.pdf
Data publikacji:
2015
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
building physics
ventilation
air exchange
indoor air quality
CO2 concentration
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
stężenie CO2
Opis:
The article presents the results of indoor air quality measurements in three university computer labs. In the spaces concerned natural ventilation system has been applied. The obtained results indicate a very low air quality in this type of room.
Źródło:
Structure and Environment; 2015, 7, 4; 194-198
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości powietrza wewnętrznego w wybranych przedszkolach
Indoor air quality in a preschool
Autorzy:
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/391209.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
building physics
ventilation
air exchange
indoor air quality
preschool building
Opis:
W artykule przedstawiono wyniki badań jakości powietrza wewnętrznego przeprowadzonych w 4 przedszkolach samorządowych. W rozpatrywanych obiektach zastosowany został system wentylacji grawitacyjnej. Uzyskane wyniki badań wskazują jednoznacznie na bardzo niską jakość powietrza w tego typy budynkach.
The article presents the results of indoor air quality (IAQ) assessment in four local preschools. The natural ventilation system was used in the buildings. Outdoor air was supplied to the premises through a leak in the external walls and air intakes were of maximum efficiency of 30 m3/h. Parameters describing IAQ were measured, such as: temperature, relative humidity and carbon dioxide concentration. Two series of studies were performed in each preschool. On the basis of the survey, it can be clearly stated that the indoor air quality in preschools is considered to be very low very low. All the analyzed parameters describing the quality do not meet the current legal requirements. Reported values of CO2 concentration exceeded three times the value set of the recommended maximum.
Źródło:
Budownictwo i Architektura; 2014, 13, 4; 41-48
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba poprawy jakości powietrza wewnętrznego w przedszkolu
Indoor air quality in a preschool
Autorzy:
Koruba, D.
Zender-Świercz, E.
Piotrowski, J.Z.
Orman, Ł.
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/390993.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
building physics
ventilation
air exchange
indoor air quality
Opis:
W artykule przedstawiono wyniki badań nad jakością powietrza wewnętrznego (IAQ) w jednym z wybranych przedszkoli. W obiekcie zastosowany został system wentylacji grawitacyjnej. Wstępne badania potwierdziły niską jakość powietrza wewnętrznego w podmiotowym budynku. W trakcie badań zaproponowano dwa usprawnienia mające na celu poprawę jakości powietrza: zwiększenie strumienia powietrza nawiewanego oraz, w drugiej kolejności, montaż urządzeń do uzdatniania powietrza wewnętrznego. Uzyskane wyniki badań wskazują, że wprowadzone usprawnienia wpływają na poprawę jakości powietrza wewnętrznego.
The article demonstrates the results of research on the indoor air quality (IAQ) in one of chosen preschools. In such facilities, the standard solution is a system of natural ventilation. Only a small percentage of such buildings is equipped with a mechanical ventilation system with adjustable parameters of the microclimate. The article presents the results of indoor air quality in the local preschool located in Kielce. In the present facility natural ventilation system was used. Preliminary studies confirmed the poor quality of indoor air in a subjected building. During the study, two improvements aimed at improving air quality were proposed. The first improvement was to increase the supply air stream. The second one concerned the installation of equipment for the treatment of indoor air. The results indicate that under certain guidelines it is possible to improve indoor air quality. As an indicator of indoor air quality, concentration of carbon dioxide was adopted. In addition, microbiological tests were performed indoors.
Źródło:
Budownictwo i Architektura; 2014, 13, 4; 7-13
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological indoor air quality in Polish schools
Mikrobiologiczna jakość powietrza w polskich szkołach
Autorzy:
Dumała, S. M.
Dudzińska, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/1818752.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
jakość powietrza
polskie szkoły
Opis:
Większość ludzi spędza ponad 90% swojego życia wewnątrz pomieszczeń m.in.: w domach, biurach i szkołach, gdzie narażeni są na działanie różnych czynników środowiska wewnętrznego (np. bioaerozoli) wpływających na ich zdrowie i kondycję fizyczną. Dlatego w ostatnich latach stale rośnie zainteresowanie badaniami wewnętrznych zanieczyszczeń biologicznych. Celem tych badań jest nie tylko szacunkowa ocena ilości mikroorganizmów w powietrzu, ale również ich identyfikacja i określenie czynników wpływających na skład bioaerozolu wewnątrz pomieszczeń. Biologiczne zanieczyszczenie powietrza w pomieszczeniach jest najczęściej spowodowane przez bakterie i grzyby. Nie tylko samo ich występowanie w formie żywych komórek patogennych może być szkodliwe dla zdrowia, ale również wydzielane przez nie substancje stanowią spore zagrożenie. W artykule zbadano szkoły z terenu Lublina pod kątem zanieczyszczeń mikrobiologicznych. Badania przeprowadzono podczas okresu grzewczego (marzec) i bez ogrzewania (maj). Próbki powietrza pobierano przed lekcją oraz podczas jej trwania. Zidentyfikowano następujące bakterie i grzyby: Bacillus lentus, Bacillus licheniformis, Bacillus pumilus, Bacillus cereus,Pseudomonas stutzeri, Micrococcus ssp., Staphylococcus xylosus, Staphylococcus saprophyticus, Staphylococcus haemolyticus, Acremonium, Aerobasidium, Aspergillus, Aspergillusniger, Alternaria, Cladosporium, Epicocum, Mucor, Penicilinium. Wśród tych drobnoustrojów wykryto obecność mikroorganizmów chorobotwórczych i o silnym działaniu uczulającym.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 1; 231-244
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Gas Chromatography for Indoor-Air Quality Control in Conservation and Renovation Studios
Autorzy:
Ligor, T.
Gorczyca, P.
Buszewski, B.
Powiązania:
https://bibliotekanauki.pl/articles/90290.pdf
Data publikacji:
2005
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
volatile organic compounds (VOCs)
air analysis
gas chromatography
occupational exposure
sample preparation
chromatografia gazowa
zagrożenia chemiczne
jakość powietrza
analiza powietrza
kontrola powietrza
Opis:
Investigations were carried out in the Department of Conservation of Painting and Polychrome Sculpture and in the Screen Printing Studio of the Faculty of Art at Nicolaus Copernicus University. Concentration of the vapours of organic solvents was measured in 2 workshops: the Art Conservation Studio and the Screen Printing Studio. This study attempts to evaluate the work environment in both studios by analysing the concentration of vapour solvents over 5 to 7 years of measurements. Volatile solvents—aliphatic and aromatic hydrocarbons, alcohols, esters and ketones—were detected in investigated workplaces. These compounds have a wide range of applications in cleaning and removing old varnishes, lacquers and paints; inhalation is the main route of exposure. Vapour was collected using an active sampling method.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2005, 11, 3; 251-261
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor Air Quality in Offices and Classrooms in Public Utility Building - a Case Study
Autorzy:
Łuszczyńska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/27314787.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
indoor air quality
bioaerosol
microorganisms
fungi
jakość powietrza w pomieszczeniach
bioaerozol
mikroorganizmy
grzyby
Opis:
A microbiological analysis of indoor air quality in offices, lecture rooms, and hallways in a public utility building has been carried out in the Lubuskie Voivodship (Poland). In one of the storage rooms, the presence of fungi on the building partition was found in the place of water infiltration as a result of a technological failure in the building. A total of 17 nonresidential interiors were examined. The total number of psychrophilic and mesophilic bacteria and the total number of fungi were sampled by the collision method with the air sampler. A qualitative analysis has been performed of fungi present in the indoor air and from building partition of the studied interiors. A total of 11 species of fungi have been specified. Relative humidity and air temperature were measured with a hygrometer. The studies showed that the number of psychrophilic bacteria in indoor air was in the range 0-730 CFU/m3 , while the number of mesophilic bacteria was slightly higher (0-896 CFU/m3 ). A high level of contamination and a large number of fungi (734 CFU/m3 ) were found in the indoor air of storage room, where the problem of biodeterioration of building partitions occurred. In the remaining rooms, the level of microorganisms was low or moderate. Microbiological tests of the outdoor air (background) did not reveal an excessive number of microorganisms in the air.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 3; 228--239
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czystosc mikrobiologiczna powietrza w gabinetach dentystycznych
Microbiological quality of indoor air in dentists offices
Autorzy:
Krogulski, A
Szczotko, M.
Powiązania:
https://bibliotekanauki.pl/articles/871713.pdf
Data publikacji:
2010
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
gabinety dentystyczne
powietrze wewnetrzne
czystosc powietrza
jakosc mikrobiologiczna
bakterie
wentylacja
aerozole
stezenie bakterii
dental office
indoor air
air quality
microbiological quality
bacteria
ventilation
aerosol
bacteria concentration
Opis:
Podczas leczenia w gabinecie stomatologicznym niektóre czynności wykonywane przez lekarza powodują powstawanie aerozolu wodno-powietrznego. Istnieją wtedy dogodne warunki dla przenikania do kropelek wody mikroorganizmów z płytki nazębnej, śliny i ropy (przy stanach zapalnych). Celem pracy była ocena wpływu czynności wykonywanych przez lekarza na stężenie bakterii w powietrzu gabinetu stomatologicznego. W tym celu w odstępach pięćdziesięciominutowych wykonano cztery serie pomiarów stężenia bakterii i grzybów w powietrzu w gabinecie stomatologicznym podczas leczenia pacjentów ze stanami ropnymi. Brak sprawnej wentylacji spowodował, że stężenie bakterii w powietrzu gabinetów wzrosło w tym czasie z niecałego tysiąca do dwóch i pół - trzech tysięcy jtk/mЗ. Wykazano, że gdy podczas pracy stomatologa jest uwalniany aerozol wodno - powietrzny; chwilowe stężenie bakterii w powietrzu pobieranym w odległości ok. Im na przeciwko pacjenta wzrasta o 2 - 3 tysiące jtk/mЗ.
It's a well-known fact that water-air aerosol can be a result of some dentist s activity during regular dental surgery and can contain broad range of microorganisms from dental plaque, saliva and pus. Assessment of dentisťs activity impact on bacteria concentration in air of dentist surgery was a main purpose of this assay. Presented data contains results of four total number of bacteria and fungi in air assays made with fifty minutes intervals. Air samples was taken in dentisťs office during regular dental surgery of patients afflicted with oral cavity infection with pus. Due to defective ventilation system, bacteria 's concentration in air samples increased from less than thousand cfu/mЗ to almost three thousands cfu/mЗ. Obtained results demonstrated that aerosol containing bacteria is released during regular dental surgery so the concentration of potentially infectious bacteria around patient and dentist can increase up to three thousands cfu/m3.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2010, 61, 1; 99-102
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrobiologiczna jakość powietrza w sklepie terrarystycznym
Microbiological quality of indoor air at reptile store
Autorzy:
Bulski, K.
Korta-Pepłowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/339549.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bioaerozol
powietrze
sklep terrarystyczny
zwierzęta
air
animals
bioaerosol
reptile store
Opis:
W ostatnich latach w Polsce wzrosła liczba sklepów terrarystycznych, zajmujących się sprzedażą gadów i płazów. Ze względu na specyfikę sprzedaży, badane środowisko pracy może być zanieczyszczone mikrobiologicznie. Według wiedzy autorów, brak jest obecnie badań dotyczących kontroli jakościowej i ilościowej próbek środowiskowych powietrza, pobranych ze strefy oddechowej pracowników (próbki bioaerozolu) w tego typu obiektach. Dlatego celem niniejszych badań była ocena narażenia pracowników i klientów sklepu na aerozol bakteryjny i grzybowy w pomieszczeniach terrarystycznych. Pomiary bioaerozolu wykonano w trzech pomieszczeniach sklepu terrarystycznego, położonego w Krakowie. Próbki bioaerozolu pobierano 6-stopniowym impaktorem kaskadowym Andersena. Największe stężenie bakterii odnotowano w powietrzu pomieszczenia, w którym przebywały zwierzęta (11 231 jtk•m-3), a grzybów w pomieszczeniu, gdzie znajdowała się kasa fiskalna (8068 jtk•m-3).
The number of pet shops that sells reptiles and amphibians increased in Poland in recent years. Due to the nature of the sale, that kind of environment can be microbiologically contaminated. There is currently no research about the control of qualitative and quantitative environmental samples of air taken from the breathing zone of the employee (bioaerosol samples). The objective of the study was the assessment of exposure to airborne bacteria and fungi aerosol. Microbiological testing of air was carried out in three rooms in reptile store in Cracow. The air samples were collected using a 6-stage Andersen’s air sampler. The results showed that the highest concentration of bacteria was observed in the room with pets (11 231 cfu•m-3) and the highest concentration of the fungi was observed in the room with cash register (8068 cfu•m-3).
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2017, 17, 2; 27-35
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigations of effect of indoor air quality on thermal comfort in residential buildings
Autorzy:
Krzaczek, M.
Tejchman, J
Powiązania:
https://bibliotekanauki.pl/articles/231320.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
budynek mieszkalny
jakość powietrza wewnętrznego
stężenie CO2
komfort cieplny
CFD
strefa oddychania osobista
obciążenie cieplne
wentylacja naturalna
residential building
indoor air quality
CO2 concentration
thermal comfort
personal breathing zone
heat load
natural ventilation
Opis:
The influence of the CO2 concentration in a local air zone in naturally ventilated residential houses on the residents’ behaviour was numerically investigated. A numerical two-dimensional CFD model of the indoor zone based on experiments performed by the authors was used. Different resident locations in the fluid domain and different inlet velocities imposed by wind were considered in simulations. The overall thermal comfort and IAQ indices were also calculated. The investigations results show that in contrast to the overall air quality, the local CO2 was strongly dependent upon the resident location, fresh air inlet velocity and ventilation system type.
Źródło:
Archives of Civil Engineering; 2014, 60, 1; 91-121
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lokalizacja szpitali a czystosc mikrobiologiczna powietrza w pomieszczeniach
Hospitals location and indoor air microbiological quality
Autorzy:
Krogulski, A
Powiązania:
https://bibliotekanauki.pl/articles/872723.pdf
Data publikacji:
2008
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
szpitale
lokalizacja
powietrze wewnetrzne
czystosc mikrobiologiczna
klimatyzacja
bakterie
grzyby
mikroorganizmy
hospital
location
indoor air
microbiological purity
air conditioning
bacteria
fungi
microorganism
Opis:
W pracy przedstawiono wyniki pomiarów stężenia mikroorganizmów w pomieszczeniach szpitali położonych w zwartej zabudowie miasta i poza miastem. Omówiono wpływ różnych czynników na stężenie bakterii i grzybów w pomieszczeniach szpitala.
The relationship between hospitals location and bacteria and fungi concentration in hospitals rooms was investigated. Hospitals situated in the city centre and outside the city were chosen to investigation. The relationship between bacteria and fungi concentration in indoor and ambient air was analyzed. In the investigation air-conditioned rooms were isolated.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2008, 59, 1; 97-102
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of road traffic on indoor air quality
Wpływ ruchu drogowego na jakość powietrza wewnętrznego
Autorzy:
Zender-Świercz, Ewa
Polański, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2174677.pdf
Data publikacji:
2022
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
particulate matter PM2.5
particulate matter PM10
Indoor Air Quality
road traffic
pyły zawieszone PM2.5
pyły zawieszone PM10
jakość powietrza wewnętrznego
ruch drogowy
Opis:
The quality of air that people breathe has become a very important parameter of quality of life. Pollution contributes to numerous diseases, problems with the absorption of knowledge, and also reduces work efficiency. The article attempts to find the relationship between road traffic and indoor air quality. The parameter used to assess air pollution was particulate matter (smog). The research was carried out in three localisations with different traffic volumes, in three places for each localisation, in the summer, autumn, and winter periods. It was found that in areas with heavy road traffic, this traffic causes an inflow of pollutants into the rooms. In low-traffic localisations, sources other than road traffic have a greater impact on the indoor air quality, especially in the cool periods (autumn, and winter)
Jakość powietrza, jakim oddycha człowiek, stała się bardzo istotnym parametrem jakości życia. Zanieczyszczenia przyczyniają się do licznych zachorowań, problemów z przyswajaniem wiedzy, a także obniżają wydajność pracy. W artykule podjęto próbę odnalezienia zależności pomiędzy natężeniem ruchu drogowego i jakością powietrza wewnętrznego. Parametrem, który wykorzystano do oceny zanieczyszczenia powietrza, był pył zawieszony (smog). Badania przeprowadzono w trzech lokalizacjach o różnym natężeniu ruchu, w trzech miejscach dla każdej lokalizacji, w okresach lato, jesień i zima. Stwierdzono, że w lokalizacji o dużym natężeniu ruchu pojazdów ruch ten powoduje napływ zanieczyszczeń do pomieszczeń. W lokalizacjach o małym natężeniu ruchu większy wpływ na jakość powietrza wewnętrznego mają inne niż ruch drogowy źródła, szczególnie w okresach chłodnych (jesień, zima).
Źródło:
Structure and Environment; 2022, 14, 4; 142--152
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Empirical cumulative distribution function of CO2 concentration increments as a descriptor of indoor air variability
Autorzy:
Szczurek, A.
Maciejewska, M.
Pietrucha, T.
Powiązania:
https://bibliotekanauki.pl/articles/208271.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
carbon dioxide
air quality
carbon
indoor air pollution
indoor air quality
indoor environment
dwutlenek węgla
jakość powietrza
węgiel
zanieczyszczenie powietrza w pomieszczeniach
jakość środowiska wewnętrznego
środowisko wewnętrzne
Opis:
Indoor air quality broadly refers to the environmental characteristics inside buildings and characterizes the physical, chemical and biological state of indoor air at some place and time. Usually it is characterized by physicochemical properties of indoor environment such as temperature, relative humidity, airflows and concentration of characteristic pollutants, e.g. carbon dioxide. They are highly variable in time. In the paper, changes of empirical cumulative distribution function (ECDF) of CO2 concentration were considered as a descriptor of indoor air variability. Using this measure, there may be performed the analysis of CO2 variation in a short as well as long term. The approach utilizes the idea of classification. A class of variation of CO2 concentration has its individual ECDF. It indicates a particular case of balance/imbalance between CO2 delivery and removal processes, including gas dispersion. The analysis is applicable for evaluating the stability of indoor environment and it may provide support for the diagnosis of the performance of the air exchange system. Exemplary results were provided for an open space office and a lecture theater.
Źródło:
Environment Protection Engineering; 2015, 41, 3; 173-187
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza jakości powietrza wewnętrznego w małym przedszkolu
Analysis of indoor air quality in a small kindergarten
Autorzy:
Gładyszewska-Fiedoruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/271034.pdf
Data publikacji:
2010
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
wentylacja
jakość powietrza
przedszkola
ventilation
air quality
kindergarten
Opis:
Najczęściej w przedszkolach człowiek zaczyna swoją edukację. Dzieci spędzają w nich od pięciu do dziesięciu godzin dziennie. Dlatego ważna jest jakość powietrza wewnętrznego. Najczęściej stosowanym systemem wentylacji w przedszkolach jest wentylacja naturalna. Dokładniej wentylacja grawitacyjna kanałowa wspomagana okresowym wietrzeniem. W badanym przedszkolu rano stężenie dwutlenku węgla nie przekracza dopuszczalnych norm. Po południu stężenia dwutlenku węgla są znacznie przekroczone - maksymalnie o 190%. Temperatura i wilgotność powietrza znajdują się w granicach normy. Rozszczelniając lub otwierając okna doprowadzamy do pomieszczeń powietrze zewnętrzne, poprawiamy w ten sposób działanie wentylacji grawitacyjnej, poprawiamy jakość powietrza wewnętrznego.
Formal education usually begins in kindergarten. Children spend five to ten hours a day there, so indoor air quality is of paramount importance. Natural ventilation (or to be more precise gravitational channel ventilation system) is by far the most common ventilation method in kindergartens; its efficiency is enhanced by airing the premises from time to time. In the kindergarten in question, carbon dioxide concentration in the morning does not exceed the permissible level. In the afternoon, however, this level is considerably exceeded (by as much as 190%). Temperature and humidity stay within the acceptable range of values. Thanks to unsealing or opening the windows, outdoor air penetrates into the rooms, which boosts the functioning of the gravitational ventilation system thus improving indoor air quality.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2010, 15, 2; 9-14
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ adsorpcji zanieczyszczeń na jakość powietrza w pomieszczeniach
Influence of pollutants adsorption on indoor air quality
Autorzy:
Sowa, J.
Powiązania:
https://bibliotekanauki.pl/articles/362724.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
jakość powietrza
adsorpcja
modelowanie
węgiel aktywny
air quality
adsorption
modeling
activated carbon
Opis:
W wielu przypadkach ograniczenie się jedynie do procesów adwektywnych przy modelowaniu jakości powietrza prowadzi do znacznych błędów. W artykule przedstawiono podstawowe zależności uproszczonego modułu adsorpcji, który mogły być stosowany z klasycznymi modelami jakości powietrza w skali makro. Przeanalizowano także wpływ adsorp- cji zanieczyszczeń powietrza na stężenia zanieczyszczeń dla hipotetycznego pomieszczenia biurowego przy różnych założeniach. Na podstawie przeprowadzonych analiz, a także na podstawie badań literaturowych, przestawiono uwagi odnośnie wpływu adsorpcji zanieczyszczeń na jakość powietrza w pomieszczeniach.
In many cases limitation just to advective processes during modelling indoor air quality leads to substantial errors. The paper presents basic relations of simplified adsorption model, that could be applied together with classic indoor air quality models of macro scale. The behaviour of hypothetical office has been analysed for different combination of assumptions. On the base of both performed analysis and literature studies some qualitative remarks have been formulated.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 251-254
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena mikrobiologiczna jakości powietrza w zakładach piekarniczych
The assessment of microbiological indoor air quality in bakeries
Autorzy:
Wołejko, E.
Kowaluk-Krupa, A.
Wydro, U.
Butarewicz, A.
Jabłońska-Trypuć, A.
Piekut, J.
Dec, D.
Łoboda, T.
Powiązania:
https://bibliotekanauki.pl/articles/399933.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
piekarnie
bakterie
grzyby
zanieczyszczenie powietrza
bacteria
fungi
indoor air quality
bakeries
Opis:
Celem niniejszej pracy była ocena stanu jakości mikrobiologicznej powietrza w zakładach piekarniczych zlokalizowanych na terenie województwa podlaskiego. Badania wykonano jesienią 2014 roku na terenie trzech zakładów piekarniczych. Próby powietrza pobierano metodą zderzeniową z użyciem próbnika powietrza MAS-100 (Merck, Niemcy). Mikrobiologiczne badania powietrza obejmowały oznaczenie ogólnej liczby bakterii psychrofilnych i mezofilnych, bakterii wskaźnikowych tj. bakterii z gatunku Pseudomonas fluorescens, gronkowców mannitolododatnich i manitoloujemnych oraz grzybów pleśniowych znajdujących się w powietrzu atmosferycznym. Zanieczyszczenie powietrza wewnętrznego w badanych piekarniach pod kątem mikrobiologicznym różniło się w zależności od rodzaju lokalizacji zakładu produkcyjnego. Stężenia występujących wewnątrz zakładów bakterii mezofilnych i Staphylococcus mannitolododatnich oraz mannitoloujemnych przekraczały wartości graniczne określone dla powietrza niezanieczyszczonego. Nie odnotowano natomiast w analizowanych piekarniach nadmiernego zanieczyszczania powietrza grzybami pleśniowymi. Najwyższą liczbę grzybów w powietrzu wykryto w piekarni 1, natomiast w pozostałych piekarniach ich liczba utrzymywała się na poziomie czystego powietrza atmosferycznego.
The aim of this study was to assess microbiological indoor air quality of selected bakeries located in the region of Podlasie. The microbiological studies were conducted in autumn in 2014 in three selected bakeries. Microbiological air counts were measured by impaction using an air sampler MAS-100 NT. The microbiological air studies, comprised the determination of the total number of psychrophilic and mesophilic bacteria, namely indicator bacteria such as: bacteria of the species Pseudomonas fluorescens, mannitol-positive and mannitol-negative Staphylococc, the total number of bacteria from the Enterobacteriaceae family and fungi found in atmospheric air. The results of the study of indoor air polluted with the analyzed groups of microorganisms differed depending on the type of test air and the location of the manufacturing plant. In the plants, the concentration of mesophilic bacteria and mannitol–positive and mannitol-negative Staphylococcus exceeded the limit values of unpolluted air, according to the Polish Standard recommendations.
Źródło:
Inżynieria Ekologiczna; 2016, 47; 182-188
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Klasyfikacja jakości powietrza wewnętrznego z zastosowaniem logiki rozmytej
CLASSIFICATION OF INDOOR AIR QUALITY USING FUZZY LOGIC
Autorzy:
SZCZUREK, Andrzej
MACIEJEWSKA, Monika
Powiązania:
https://bibliotekanauki.pl/chapters/1965450.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Opis:
Jakość powietrza wewnętrznego (IAQ) charakteryzuje fizyczny, chemiczny oraz biologiczny stan powietrza w pewnym miejscu i czasie. Informacja o niej jest bardzo potrzebna. Wielkość ta nie jest jednak mierzalna instrumentalnie w sposób bezpośredni. Jedną z możliwości określenia IAQ jest wykorzystanie modelu jej zależności od innych mierzalnych wielkości. W tej pracy rozważono możliwość zastosowania logiki rozmytej do klasyfikacji jakości powietrza wewnętrznego. Klasyfikację przeprowadzono na podstawie trzech paramentów powietrza wewnętrznego: temperatury, wilgotności względnej i stężenia ditlenku węgla. Model rozmyty wykorzystuje wiedzę ekspercką o związku między tymi parametrami a odczuciami człowieka. Porównano wyniki uzyskane z wykorzystaniem modeli bazujących na logice klasycznej i na logice rozmytej. W tym celu wykorzystano dane z monitoringu powietrza w przykładowym pomieszczeniu. Z przedstawionych rezultatów i ich dyskusji wynika, że zastosowana metoda jest dobrą propozycją rozwiązania problemu klasyfikacji jakości powietrza wewnętrznego.
Indoor air quality (IAQ) characterizes physical, chemical and biological state of air in a defined location and time. This quantity is not measurable with analytical methods. One of alternative approaches applied for its determination utilizes the fact that IAQ depends on many factors and those dependencies may be modelled. In this work we considered application of fuzzy logic to the classification of indoor air quality. The classification was carried out based on three parameters: temperature, relative humidity and carbon dioxide concentration. Fuzzy model utilized an expert knowledge about the relationship between these factors and human perception of the conditions around him. We compared results of classification obtained with classical, binary logic and fuzzy logic. Air monitoring data from an exemplary room was utilized for this purpose. Based on the presented results and their discussion, the applied method is an interesting option for solving a problem of indoor air quality classification.
Źródło:
Powietrze atmosferyczne. Jakość – zagrożenia – ochrona; 281-289
9788374939423
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of viable fungi in indoor air: a case study from Tagore’s residence at Jorasanko, India
Autorzy:
Bhattacharyya, S.
Mukherjee, D.
Sarkar, P.
Ghosh, S.
Samaddar, B.
Chaudhuri, P.
Powiązania:
https://bibliotekanauki.pl/articles/11560.pdf
Data publikacji:
2015
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
assessment
viable fungi
fungi
indoor air
indoor environment
Tagore’s residence
Jorasanko
India
Opis:
Indoor environment is significant with respect to human health especially if it is concerned when the building is v. Aim of very old. In the present study was to assess the presence of airborne fungi at an old building in Kolkata India where lots of tourists are exposed every day. Residence of famous Nobel laureate poet Rabindranath Tagore (built in the 18th century and presently used as a famous museum) in Kolkata, West Bengal was selected for this study and the indoor fungi from different room of the museum were assessed by using exposure plate technique. Humidity, temperature, wind speed and illuminance were also measured by hygrometer, thermometer anemometer and lux-meter respectively. The fungal species isolated from the air samples of different rooms were Aspergillus sp., Penicillium sp., Paecilomyces sp., Trichoderma sp, Alternaria sp Verticillium sp, Fusarium sp, Cladosporium sp, Yeast, Curvularia sp. and Helminthosporium sp. among them, Aspergillus sp. (71.4% at monsoon at library), Penicillium sp (57% at summer at library), Paecilomyces sp.(91% at monsoon at manuscript room) are mostly dominated pathogens, which may harm the workers and visitors of the museum. No significant correlation among colony forming unit of fungi with illuminance, wind speed and temperature in the tested indoor environment was noted whereas, the humidity in indoor environment played a crucial (P<0.05) role. Round the year humidity control may be required for maintaining healthy environment.
Źródło:
International Letters of Natural Sciences; 2015, 06
2300-9675
Pojawia się w:
International Letters of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Biophilic Installations for Indoor Air Quality Improvement
Wykorzystanie instalacji biofilicznych do poprawy jakości powietrza wewnętrznego
Autorzy:
Staszowska, Amelia
Powiązania:
https://bibliotekanauki.pl/articles/1811733.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
indoor air quality
biophilic installation
phytoremediation
green walls
jakość powietrza wewnętrznego
instalacje biofiliczne
fitoremediacja
zielone ściany
Opis:
This paper discusses the possibilities and limitations of using biophilic installations to improve the indoor air quality in residential and commercial spaces. Modular plant systems can provide the support or, in smaller facilities, even an alternative to the conventional indoor air purification techniques, such as filtration. The unquestionable advantage of green walls is their comprehensive influence on the indoor air quality by shaping both appropriate thermal and humidity conditions as well as the chemical air composition. However, these constructions are not mechanical systems and therefore, the effectiveness of these specific types of living air purifiers in removing gaseous pollutants and particulate matter cannot be expected to match the level of traditional systems.
W pracy omówiono możliwości i ograniczenia wykorzystania instalacji biofilicznych do poprawy jakości powietrza wewnętrznego w przestrzeniach mieszkalnych i komercyjnych. Roślinne systemy modułowe mogą stanowić wsparcie lub w mniejszych obiektach alternatywę dla konwencjonalnych technik oczyszczania powietrza wewnętrznego jakim jest filtracja. Niekwestionowaną zaletą zielonych ścian jest ich kompleksowy wpływ na jakość powietrza wewnętrznego poprzez kształtowanie zarówno odpowiednich warunków cieplno-wilgotnościowych jaki i składu chemicznego powietrza. Nie są to jednak układy mechaniczne i nie można oczekiwać, aby te swoistego rodzaju żywe oczyszczacze powietrza osiągały skuteczności w usuwaniu zanieczyszczeń gazowych i pyłowych na poziomie tradycyjnych systemów.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 2; 716-726
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perceived indoor air quality and psychosocial work environment in office, school and health care environments in Finland
Autorzy:
Tähtinen, Katja
Remes, Jouko
Karvala, Kirsi
Salmi, Kari
Lahtinen, Marjaana
Reijula, Kari
Powiązania:
https://bibliotekanauki.pl/articles/2116581.pdf
Data publikacji:
2020-06-16
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
Indoor Air Questionnaire
school
health care
perceived indoor environment
reference material
office
Opis:
ObjectivesThe study examined the extent and prevalence of perceived indoor environment-related (IE-related) symptoms environmental complaints and psychosocial work environmental factors in Finnish office, school and health care environments.Material and MethodsThe data were collected from non-industrial workplaces (N = 455) in 2011–2012 and 2015–2017 using the Finnish Institute of Occupational Health’s Indoor Air Questionnaire (IA Questionnaire). Suspicion of IE-related problems was reported in 59% of workplaces. The data consisted of 28 826 employees’ responses.ResultsThe employees reported symptoms and environmental discomfort in office environments less often than in school or health care environments. The most often reported IE-related complaints were stuffy air (39% of respondents), dry air (34%) and insufficient ventilation (33%). The most often reported symptoms were irritation of the nose (27% of respondents), irritation of the eyes (26%), and hoarse or dry throat (24%). The results showed differences between the perceived IE in office, school and health care environments.ConclusionsCompared to earlier findings, the most often perceived IE-related symptoms and complaints have increased in Finnish health care environments. The office employees’ perceptions of psychosocial work environment remained fairly unchanged whereas health care personnel more often assessed their psychosocial environment as positive compared to previous reports. Instead of exact reference values, comparing the results of IA Questionnaires with the distributions and mean values of the results of this study may be more informative for those striving to solve IE-related problems. The presented distribution and mean values of perceived symptoms, environmental complaints and psychosocial work environment might help to relate the results to other workplaces. This, in turn, might increase the understanding that IA Questionnaire results are influenced by many factors. The results presented can be used as new reference material when interpreting the results of IA Questionnaires in office, school and health care environments.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2020, 33, 4; 479-495
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ tlenków azotu na jakość powietrza w pomieszczeniach
Impact of nitrogen oxides on the indoor air quality
Autorzy:
Bieniek, M.
Powiązania:
https://bibliotekanauki.pl/articles/340741.pdf
Data publikacji:
2008
Wydawca:
Główny Instytut Górnictwa
Tematy:
tlenki azotu
IAQ
jakość powietrza
zanieczyszczenia powietrza
nitrogen oxides
air quality
atmospheric pollutants emission
Opis:
Z uwagi na fakt, że przeważająca większość ludzi spędza około 70% czasu w pomieszczeniach (budynkach mieszkalnych, pomieszczeniach pracy i nauki, obiektach handlowych), konieczna jest ich ochrona przed bezpośrednim wpływem zmiennych zewnętrznych warunków klimatycznych, a także zapewnienie poczucia względnego komfortu przebywania, warunkowane stworzeniem właściwego mikroklimatu pomieszczenia IAQ (Indoor Air Quality). Dominujący wpływ na jakość powietrza wewnątrz budynków mają powstające w pomieszczeniach wentylowanych zanieczyszczenia. Ich źródłem są użytkownicy pomieszczeń oraz urządzenia stanowiące wyposażenie pomieszczeń, a także materiały budowlane użyte do wykończenia wnętrza (farby, lakiery, dywany, wykładziny syntetyczne). Odrębną grupę stanowią zanieczyszczenia wprowadzane do pomieszczeń wraz z powietrzem zewnętrznym, przy czym za zanieczyszczenie powietrza uważa się każdy jego składnik, który powoduje odstępstwa od klasycznego składu powietrza atmosferycznego. Do zanieczysz-czeń powietrza atmosferycznego zalicza się więc związki zawarte w spalinach, pyłki roślin, parę wodną, ale także jego naturalne składniki (O2, N2, CO2), jeżeli ich udział w powietrzu zewnętrznym jest różny od określonego dla klasycznego składu powietrza. Badania przeprowadzone przez amerykańską Agencję Ochrony Środowiska (???) wykazały, że w powietrzu wewnętrznym stężenia wielu zanieczyszczeń mogą być kilka razy większe niż w powietrzu zewnętrznym. Obowiązujące w Polsce przepisy prawne nie poruszają problemu jakości powietrza wewnątrz pomieszczeń, dotyczą jedynie wymaganej ilości powietrza wentylacyjnego i dopuszczalnych wartości stężeń substancji zanieczyszczających. Bardziej szczegółowo opracowano normy stężeń zanieczyszczeń na stanowiskach pracy, w których wyszczególniono dopuszczalne wartości normatywne dla 352 substancji chemicznych i 17 rodzajów pyłów, podczas gdy w przepisach dotyczących pomieszczeń przeznaczonych na stały pobyt ludzi wzięto pod uwagę jedynie 35 substancji zanieczyszczających. Ustawodawca pominął wiele zanieczyszczeń, co do których obecności i negatywnego wpływu na użytkowników pomieszczeń mieszkalnych nie ma wątpliwości, jak np. dwutlenek azotu. Postanowiono więc przybliżyć tę problematykę. Podjęto badania w celu określenia wpływu tlenków azotu na jakość powietrza w pomieszczeniach. Ich wyniki zostały omówione w niniejszym artykule.
Due to the fact, that predominantly most people spend ca. 70% of time indoors (dwelling buildings, rooms for work and learning, trade objects), their protection is necessary against direct changing of external climatic conditions. And also assuring of feeling of relative comfort of habitation conditioned by creation of proper indoor microclimate IAQ (Indoor Air Quality). Pollution arising in ventilated rooms has predominant impact on the indoor air quality. Its source are users of rooms as well as devices being equipment of rooms, and also building materials used to finish interior (paints, varnishes, carpets, synthetic facings). A separate group form the pollutants introduced to rooms together with an external air, and each component, which causes departures from classic composition of atmospheric air, is considered as a pollutant. Therefore, compounds contained in fumes, pollens of plants, water vapor are classified to be atmospheric air pollutants, but also its natural components (O2, N2, CO2), if their part in the external air differs from defined for classic composition of air. Researches conducted by U.S. Environmental Protection Agency (EPA) showed that concentrations of many pollutants in the indoor air could be few times higher than in the outdoor air. Legal regulations valid in Poland do not refer to the problem of indoor air quality, and concern required quantities of ventilating air and admissible values of polluting substances concentrations only. In more details there were developed standards of pollutants' concentrations at working posts, where admissible standardized values were specified for 352 chemical substances and 17 kinds of dusts. Whereas, only 35 polluting substances were taken into account in regulations related to rooms designed for permanent stay of people. Legislator skipped many contaminants, which presence and negative impact on users of habitable rooms is undoubted, e.g. nitrogen dioxide. Therefore, it was decided to study closer these problems and to conduct researches in this area. In this connection, researches were undertaken to define the nitrogen oxides' impact on the indoor air quality. Their results were discussed in the present article.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2008, 2; 5-17
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość powietrza wewnętrznego w typowym przedszkolu w Białymstoku
Indoor air quality in a typical kindergarten in Bialystok
Autorzy:
Gładyszewska-Fiedoruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/403063.pdf
Data publikacji:
2012
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
stężenie dwutlenku węgla
jakość powietrza wewnętrznego
air quality
kindergarten
Opis:
W przedszkolach dzieci spędzają od pięciu do dziesięciu godzin dziennie, dlatego ważna jest jakość powietrza w pomieszczeniach. Najczęściej stosowanym systemem wentylacji w przedszkolach jest wentylacja naturalna, a dokładniej wentylacja grawitacyjna kanałowa wspomagana okresowym wietrzeniem. W badanym przedszkolu stężenie dwutlenku węgla rano nie przekracza dopuszczalnych norm. Po południu stężenia dwutlenku węgla znacznie przekraczają normy – maksymalnie o 97%. Temperatura i wilgotność powietrza są w granicach normy. Rozszczelniając lub otwierając okna doprowadzamy do pomieszczeń powietrze zewnętrzne i poprawiamy w ten sposób działanie wentylacji grawitacyjnej, a przez to poprawiamy jakość powietrza wewnętrznego.
Formal education usually begins in kindergarten. Children spend five to ten hours a day there, so indoor air quality is of paramount importance. Natural ventilation (or to be more precise gravitational channel ventilation system) is by far the most common ventilation method in kindergartens; its efficiency is enhanced by airing the premises from time to time. In the kindergarten in question, carbon dioxide concentration in the morning does not exceed the permissible level. In the afternoon, however, this level is considerably exceeded (by as much as 97%). Temperature and humidity stay within the acceptable range of values. Thanks to unsealing or opening the windows, outdoor air penetrates into the rooms, which boosts the functioning of the gravitational ventilation system thus improving indoor air quality.
Źródło:
Budownictwo i Inżynieria Środowiska; 2012, 3, 1; 33-38
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stężenia ozonu w pomieszczeniach przeznaczonych na czasowy pobyt ludzi
Ozone concentrations in Lublin non-occupational environments
Autorzy:
Staszowska, A.
Dudzińska, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/127306.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ozon
powietrze wewnętrzne
jakość powietrza wewnętrznego
ozone
indoor air
indoor air quality
non-occupational environments
Opis:
Badania przeprowadzono w pomieszczeniach przeznaczonych na czasowy pobyt ludzi: w pokojach biurowych i punktach kserograficznych zlokalizowanych na terenie miasta Lublina. Badania stężenia ozonu w powietrzu wewnętrznym przeprowadzone zostały w dwóch okresach: w okresie letnim i w sezonie grzewczym. Próbki do badań pobierano metodą pasywną. Pomiaru stężenia ozonu dokonano metodą spektrofotometryczną. Stężenia ozonu dla okresu letniego wyniosły: 0,01 -K),04 mg/m3 dla pomieszczeń biurowych oraz 0,008+0,176 mg/m3 dla punktów kserograficznych. Natomiast w sezonie grzewczym stężenia ozonu kształtowały się w następujących przedziałach: 0,007+0,018 mg/m3 dla pomieszczeń biurowych i 0,001-K),015 mg/m3 dla punktów kserograficznych. W punktach kserograficznych dopuszczalne stężenie 0,15 mg/m3 zostało przekroczone w sezonie letnim w dwóch przypadkach. W sezonie grzewczym nie odnotowano przekroczenia dopuszczalnego stężenia w punktach kserograficznych. W przypadku pomieszczeń biurowych dopuszczalne stężenie wynoszące 0,15 mg/m3 nie zostało przekroczone.
Ozone is the common component of indoor air. Because of its high reactivity it plays an important role in forming of indoor air quality, which influence directly on health of interior occupants. It is a well-known fact, that ozone can damage the respiratory system, inflames and irritates respiratory tissues, and can worsen asthmatic symptoms in individuals with asthma. Ozone exposure can produce symptoms such as coughing, chest tightness and impaired breathing. Elevated exposures have the potential to induce permanent lung damage, and even increase the risk of premature death in persons with poor health. Hence, there is a need to measure the concentrations of ozone in indoor air environments. The indoor ozone concentration depends on the outdoor ozone concentrations, the rate at which indoor air is exchanged with outdoor air, interior air circulation, indoor sources of ozone (eg ozone generators, electrostatic air cleaners, photocopiers, and laser printers), the rate at which ozone is removed by indoor surfaces, and reactions between ozone and other chemicals in the air. The objective of this study was to examine ozone concentrations in indoor air in selected non-occupational environments: office rooms and Xerox service points. Summer time and cold (heating) season was examined. Samples were collected using passive method. The ozone concentration on summer time was within the range of 0.04-K).01 mg/m3 for office rooms and 0.008-0.176 mg/m3 for Xerox points. In two examined Xerox places the permitted level of ozone (0.15 mg/m3) was exceeded in summer time. In cold time the permitted level of ozone was not exceeded in any Xerox points. hi offices rooms the permitted level of ozone was not achieved.
Źródło:
Proceedings of ECOpole; 2011, 5, 2; 623-627
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy consumption, thermal comfort and indoor air quality assessment in a school building using three air-cooling systems
Autorzy:
Romero, María Jesús
Comino, Francisco
Ruiz de Adana, Manuel
Powiązania:
https://bibliotekanauki.pl/chapters/31233748.pdf
Data publikacji:
2021
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
HVAC systems
classroom
thermal comfort
energy consumption
energy simulation
Opis:
Efficient air-cooling systems for hot climatic conditions, such as southern Europe, are required in the context of Nearly Zero Energy Buildings. Regenerative indirect evaporative coolers, RIEC, and desiccant regenerative indirect evaporative coolers, DRIEC, could be considered an innovative alternative to direct expansion conventional systems, DX. The main objective of this work was to evaluate the seasonal performance of three air-cooling systems in terms of thermal comfort, air quality and energy consumption in a standard classroom. Several energy simulations were carried out to evaluate these indexes in the climate zone of Lampedusa, in Mediterranean area, by using European Standards. The simulations were based on experimentally validated models. DRIEC system was the recommended system to serve a standard classroom in terms of thermal comfort and RIEC system in terms of air quality and energy consumption. DX system achieved similar comfort favourable conditions to DRIEC system. However, it always worked in III unfavourable category of air quality and consumed three times more than RIEC and DRIEC systems.
Źródło:
Innovations – Sustainability – Modernity – Openness. Modernity in engineering; 115-121
9788366391901
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zanieczyszczenie powietrza w budynkach preparatami pochodzenia smołowego
Indoor air pollution in buildings by chemicals originated from tar products
Autorzy:
Niesłochowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/183219.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniki Budowlanej
Tematy:
zanieczyszczenie powietrza
zanieczyszczenie chemiczne
powietrze wewnętrzne
budynek mieszkalny
budynek użyteczności publicznej
olej impregnacyjny
XYLAMIT
środek bitumiczny
rozpuszczalnik organiczny
para organiczna
emisja par
badanie laboratoryjne
chromatografia gazowa
technika analiz
air pollution
chemical contamination
indor air
dwelling house
public building
impregnation oil
tar composition
organic solvent
laboratory test
gas chromatography
analysis technique
Opis:
Wyroby budowlane pochodzenia smołowego są przyczyną zanieczyszczenia powietrza wewnątrz budynków. Dotyczy to budynków starych, w których konstrukcje drewniane konserwowane byly preparatami zawierającymi bitumy (olej impregnacyjny Xylamit - lepik smołowy) oraz budynków nowych, w których stosowano preparaty hydroizolacyjne zawierające rozpuszczalniki węglowodorowe. Zastosowanie nowoczesnych technik analitycznych, takich jak GC-MS, desorpcja termiczna, mikroekstrakcja, pozwoliło zidentyfikować przyczynę chemicznego zanieczyszczenia pomieszczeń. W artykule omówiono zwięźle kilka przypadków takich interwencji zaobserwowanych w ostatnich latach.
Buildings materials containing tar products are source of indoor air pollution in buildings. It concerns particularly to old buildings in which wooden structure were impregnated by tar compositions (creosote oil, Xylamit oil tar) and the new one in which bituminous seal containing hydrocarbon solvents were used. New analytical methods (GC-MS, thermal desorption, microextraction) enable to identify in details a reason of chemical indoor air pollution. Some case studies noticed in last years were described briefly.
Źródło:
Prace Instytutu Techniki Budowlanej; 2011, R. 40, nr 2, 2; 3-14
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of electronic cigarette (EC) aerosols on particle size distribution in indoor air and in a radon chamber
Autorzy:
Khalaf, Hyam Nazmy
Mostafa, Mostafa Y. A.
Zhukovsky, Michael
Powiązania:
https://bibliotekanauki.pl/articles/146856.pdf
Data publikacji:
2019
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
size distribution
ultrafine particles
UFPs
electronic cigarette
EC
radioactive aerosols
rozkład wielkości
ultradrobne cząstki
e-papieros
aerozole radioaktywny
Opis:
Particle size distribution is an important factor governing whether aerosols can be deposited in various respiratory tract regions in humans. Recently, electronic cigarette (EC), as the alternative of tobacco cigarette, has become increasingly popular all over the world. However, emissions from ECs may contribute to both indoor and outdoor air pollution; moreover, comments about their safety remain controversial, and the number of users is increasing rapidly. In this investigation, aerosols were generated from ECs and studied in the indoor air and in a chamber under controlled conditions of radon concentration. The generated aerosols were characterized in terms of particle number concentrations, size, and activity distributions by using aerosol diffusion spectrometer (ADS), diffusion battery, and cascade impactor. The range of ADS assessment was from 10–3 µm to 10 µm. The number concentration of the injected aerosol particles was between 40 000 and 100 000 particles/cm3. The distribution of these particles was the most within the ultrafi ne particle size range (0–0.2 µm), and the other particle were in the size range from 0.3 µm to 1 µm. The surface area distribution and the mass size distribution are presented and compared with bimodal distribution. In the radon chamber, all distributions were clearly bimodal, as the free radon decay product was approximately 1 nm in diameter, with a fraction of 0.7 for a clean chamber (without any additional source of aerosols). The attached fraction with the aerosol particles from the ECs had a size not exceeding 1.0 µm.
Źródło:
Nukleonika; 2019, 64, 1; 31-38
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikroorganizmy w kurzu z pomieszczeń na przykładzie miasta Lublina
Characterization of the microbial community in settled dust samples from indoor environments in Lublin
Autorzy:
Staszowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/126364.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mikroorganizmy
powietrze wewnętrzne
kurz domowy
jakość powietrza wewnętrznego
microorganisms
indoor air
house dust
indoor air quality
Opis:
W pracy jest przedstawiona charakterystyka mikrobiologiczna próbek kurzu zebranych w pomieszczeniach mieszkalnych i placówkach edukacyjnych zlokalizowanych na obszarze miasta Lublina. W kurzu najczęściej spotykanymi bakteriami były pałeczki Gram-dodatnie. Większość należała do rodzaju Bacillus. W próbkach kurzu z placówek edukacyjnych największą koncentrację bakterii stanowił gatunek Bacillus subtillis. Największą grupę po pałeczkach Gram-dodatnich spotykanych w kurzu były ziarniaki Gram-dodatnie. Głównie był to rodzaj Micrococcus, a dominującym gatunkiem był Micrococcus luteus. W kurzu znajdywały się także Gram-dodatnie ziarniaki z rodzaju Staphylococcus oraz Gram-ujemne pałeczki. W przypadku grzybów zawartych w kurzu dominującymi rodzajami były Aspergillus (głównie gatunek Aspergillus nigerii) oraz Penicillium. Grzyb z rodzaju Cladosporium był także spotykany w badanych próbkach.
Dust particles collected from indoor environments may contain hundreds of chemically and biologically active components, which can cause many adverse health effects and deterioration of building materials. While all types of microorganisms can cause problems indoors, bacteria and fungi are most commonly associated with indoor air quality complaints. Some of them produce mucus and excrete chemicals which can provoke allergy, respiratory system and skin irritation, headache, or fatigue. This study was designed to obtain information about characterization of the microbial community in settled dust samples from indoor environments of the Lublin area. Dust samples were collected from households and educational establishments. Microbial species and their concentrations were determined by culture analysis. The concentrations and proportions of morphologically distinguishable culturable bacteria and fungi in dust samples was as follows. In case of bacteria the most commonly found were Gram-positive rods, predominantly Bacillus spp. (Bacillus subtillis) and cocci - genus Micrococcus (Micrococcus leutus) and Staphylococcus. Fungi were represented by genus Aspergillus (mainly Aspergillus nigerii), Penicillium, and Cladosporium. Additionally, microbial concentrations of similar environments vary between sample types, eg total amount of fungi has been higher in dust from textile covered floor than in samples from bare floor.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 325-328
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Case Study of the PM2.5 and PM10 Local Elimination Device – The Impact on Indoor Air Quality
Autorzy:
Szatyłowicz, Ewa
Siemiończyk, Emilia
Hawrylik, Eliza
Powiązania:
https://bibliotekanauki.pl/articles/24201765.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
air protection
air purification
particulate matter
PM2.5
PM10
Opis:
Due to its irritating, allergenic, toxic, pathogenic, and carcinogenic effects, suspended particulate matter (PM) seriously threatens human health. Therefore, it seems obvious to control the level of concentration of PM2.5 and PM10 particles and their reduction in the indoor environment such as homes, workplaces, or public utilities. In the following work, an attempt was made to determine the efficiency of a home air purifier based on the concentration of PM2.5 and PM10 particles at selected measurement points in a teaching room located in the building of the Bialystok University of Technology. The tests were carried out in March and in April 2021, using the DT-96 meter, which measured the concentration of PM2.5 and PM10 in the air. The study included the time and intensity of air purifier operation. In addition, reference was made to the concentration of PM2.5 and PM10 in outdoor air, which was measured at measuring stations in the city of Bialystok. The obtained test results made it possible to assess the initial state of air quality in the test room, as well as to determine the parameters affecting the best efficiency of the air purifier and to notice the dependencies in changes in the concentration of PM2.5 and PM10 between the indoor and outdoor environment.
Źródło:
Journal of Ecological Engineering; 2023, 24, 5; 32--39
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air Filtration and Sterilization in Ventilation Systems According to the New Paradigm
Autorzy:
Cepiński, Wojciech
Szałański, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2202141.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
pathogen
filtration
ventilation
indoor air pollution
indoor air quality
COVID-19
SARS-CoV-2
air handling unit
Opis:
The paper deals with the subject of increasing the efficiency of air purification in ventilation systems in situations of unusual hazardous indoor air pollutants. It analyzes possible locations of additional filtering and sterilizing elements in the installation to eliminate their return to the rooms. The quantities of pollutants in particular parts of the system were determined for a given fan configuration in the air handling unit and a possible leakage in the heat recovery system. Guidelines were proposed for the design and construction of systems to enable rapid modification of systems in the event of unusual contamination or pathogens in the indoor air.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 25--34
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of risk perception connected with exposure to indoor air pollution in the group of inhabitants of Silesian Voivodeship
Ocena percepcji zagrożeń związanych z narażeniem na zanieczyszczenie powietrza wnętrz w grupie mieszkańców województwa śląskiego
Autorzy:
Krupa, Karolina
Piekut, Agata
Złotkowska, Renata
Powiązania:
https://bibliotekanauki.pl/articles/1178779.pdf
Data publikacji:
2012
Wydawca:
Instytut Medycyny Wsi
Tematy:
health risk
indoor air pollution
risk perception
Opis:
Introduction. Population increasingly draws attention to the issues concerning the environment degraded by the progress of civilization and the impact of this process on health. However, public awareness of the risk exposure to indoor contaminants is lagging a long way behind knowledge regarding outdoor environmental hazards. The aim of the study was to assess the risk perception related to exposure to indoor environmental factors in the population of Silesia. Materials and methods. In this study the electronic version of a questionnaire survey – downloaded on the website www.moja-ankiety.pl. was used. During the 3-months duration of the project 552 subjects participated in the survey. In the study participated the Silesian Voivodeship inhabitants such as chat rooms users, newsgroups and online forum participants. Data analysis was performed by using statistical program – STATA Version 8 SE [9], where the Kruskall-Wallis test and χ 2 test were applied. Statistical significance was assessed at p value *0.05. Results. Despite the low perception of environmental health hazards inside the dwellings, the majority of respondents were able to indentify health effects and ways to reduce exposure to indoor air pollution. Both gender, place of residence, education level and age significantly affected the level of perception of respondents on the risk connected with exposure to indoor air pollution. Conclusion. It is necessary to continuously work on raising public awareness of environmental health hazards in confined spaces, the causes of their occurrence, types, effects and above all the ways to counter these threats.
Wstęp. Populacja mieszkańców zwraca coraz większą uwagę na kwestie związane z degradacją środowiska w wyniku postępu cywilizacyjnego i skutku tego procesu na zdrowie. Jakkolwiek ich świadomość narażenia na zanieczyszczenia wnętrz jest znacznie mniej zaawansowana w stosunku do zagrożeń środowiskowych z zewnątrz. Celem tego badania była ocena ryzyka związanego z narażeniem na czynniki środowiskowe wnętrz u mieszkańców województwa śląskiego. Materiały i metody. W tym badaniu zastosowano ankietę w wersji elektronicznej umieszczonej na stronie internetowej www.moja-ankiety.pl. W czasie trzymiesięcznych badań udział wzięło 552 uczestników, mieszkańców województwa śląskiego takich jak: użytkownicy czatów, grup dyskusyjnych i forów internetowych. Analiza danych była przeprowadzona przy użyciu programu statystycznego STATA Version 8 SE [9], gdzie zastosowano testy Kruskall-Wallis i χ 2. Istotność statystyczna była oceniona na poziomie wartości p*0,05. Wyniki. Pomimo niskiej percepcji odnośnie zdrowotnych zagrożeń środowiskowych wewnątrz pomieszczeń, większość respondentów była w stanie ocenić skutki zdrowotne i sposoby ograniczenia narażenia na zanieczyszczenia powietrza wnętrz. Zarówno płeć, miejsce zamieszkania, poziom wykształcenia jak i wiek wywierały znaczny wpływ na poziom percepcji respondentów co do ryzyka związanego z narażeniem na zanieczyszczenie powietrza wewnątrz. Wnioski. Koniecznym jest stałe podnoszenie społecznej świadomości dotyczącej środowiskowych zagrożeń zdrowia w pomieszczeniach zamkniętych, przyczyn ich powstawania, rodzajów, skutków i przede wszystkim sposobów zwalczania tych zagrożeń.
Źródło:
Medycyna Środowiskowa - Environmental Medicine; 2012, 15, 3; 46-54
1505-7054
2084-6312
Pojawia się w:
Medycyna Środowiskowa - Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor Air Quality in a Selected Health Resort Facility: Analysis of PM10, PM2.5 and 222Rn Concentrations
Autorzy:
Merenda, Beata
Maciejewski, Piotr
Bezyk, Yaroslav
Sówka, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/2202169.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
health resort
indoor air
particulate matter
PM
222Rn
Opis:
This paper discusses the importance of indoor air quality and indicates its relation with outdoor air quality in the area of spa treatment. Significant factors and sources causing indoor air pollution by particulate matter and radon are considered. Particular attention is drawn to specific functions of health resorts in spa treatment in the context of the importance of indoor and outdoor air for patients staying in the resorts. It is underlined the specificity of health resorts providing treatment for patients classified as the group most sensitive to air pollution, i.e. people with chronic respiratory diseases. The study comprised measurements of 24-h concentrations of PM10, PM2.5 and 10-minute instantaneous concentrations of radon-222 (222Rn) from February 5 to February 25, 2021 in a treatment room of one of the Polish spas located in Lower Silesia. The analysis of interactions between the concentrations of two fractions of particulates PM10 and PM2.5 was presented. The interaction and dependence of factors affecting the elevated values of concentrations of the studied pollutants were discussed. The presented analyses showed that the concentrations of the studied pollutants were influenced by air exchange and air infiltration from outside to inside. In the case of short-term measurements of 222Rn activity concentration in the air, it was found that the observed changes in hourly concentrations of 222Rn are analogous to those observed in residential buildings. For the specific time intervals, the variation of PM concentrations and 222Rn activity concentration was found to be similar.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 202--215
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie zmienności w czasie parametrów powietrza wewnętrznego z zastosowaniem metody DAEs
DAES METHOD FOR TIME-VARYING INDOOR AIR PARAMETERS EVALUATION
Autorzy:
KWIATKOWSKA, Marlena
Powiązania:
https://bibliotekanauki.pl/chapters/2230950.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
parametry powietrza wewnętrznego
dynamika układu
równania różniczkowo-algebraiczne
metoda DAEs
Opis:
W pracy przeprowadzono analizę szeregów czasowych parametrów powietrza wewnętrznego (temperatury, stężenia ditlenku węgla i wilgotności względnej). Jako metodę do liczbowego wyrażania zachodzących zmian wykorzystano modele o strukturze różniczkowej (ODEs) i różniczkowoalgebraicznej (DAEs). Ze względu na zdecydowanie zróżnicowane tempo zmian parametrów powietrza wewnętrznego, do opisu zachodzących zależności wybrano model (DAEs). Potencjalnym obszarem zastosowań prezentowanego modelu jest predykcja parametrów powietrza wewnętrznego, wykorzystywana w układach automatycznej regulacji.
This paper concerns time series analysis of indoor air parameters, such as temperature, carbon dioxide concentration and relative humidity. As the time series quantifying methods differential and differential algebraic models were used. Because of strongly varied changes rate of indoor air parameters, differential- algebraic model (DAEs) was chosen to describe occurring dependencies. The promising future application area for presented DAEs model is indoor air parameters prediction, used in the automatic control systems.
Źródło:
Interdyscyplinarne zagadnienia w inżynierii i ochronie środowiska 6; 214-220
9788374938976
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwość poprawy jakości powietrza w polskich szkołach w wyniku modernizacji opartej na zasadach zrównoważonego rozwoju
Autorzy:
Sowa, J.
Panek, A.
Powiązania:
https://bibliotekanauki.pl/articles/362510.pdf
Data publikacji:
2005
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
jakość powietrza wewnętrznego
zasada zrównoważonego rozwoju
indoor air quality
Opis:
The paper describes part of the results of the Polish/Norwegian scientific cooperation within the project SUREBUILD, funded by the Norwegian Ministry of Foreign Affairs. The whole project is devoted to sustainable redevelopment of buildings in Poland, but special attention was paid to Polish schools constructed between 1958-1966 (the "Millenium" schools). Potential technologies for sustainable modernization of Polish schools were analyzed taking into consideration energetic, environmental, economic and other related criterions. Substantial part of the work was devoted to fin d the economically feasible technologies that might improve current unsatisfactory level of indoor air quality in Polish schools. The paper presents general recommendations for the moderniza- tion of ventilation system s in Polish schools as well as describes the technologies selected for school in Zgierz, the case study object of the project.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2005, T. 1; 305-314
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar temperatury i wilgotności względnej powietrza w sali dydaktycznej
MEASUREMENT OF TEMPERATURE AND RELATIVE HUMIDITY OF INDOOR AIR IN THE LECTURE HALL
Autorzy:
PIETRUCHA, Tomasz
Powiązania:
https://bibliotekanauki.pl/chapters/2230716.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
mikroklimat pomieszczenia
sala dydaktyczna
pomiary
temperatura powietrza wewnętrznego
wilgotność względna powietrza wewnętrznego
Opis:
Wykonanie pomiaru temperatury i wilgotności względnej powietrza wewnętrznego na potrzeby oceny mikroklimatu pomieszczenia wiąże się z wieloma problemami, które trzeba rozwiązać. Są to m. in. wybór odpowiednich przyrządów pomiarowych, ich odpowiednia lokalizacja oraz wystarczająca ilość urządzeń pomiarowych. Każdy z tych aspektów przekłada się na jakość uzyskanej informacji o badanych parametrach powietrza. W artykule przedstawiono wyniki pomiarów temperatury i wilgotności względnej powietrza w sali wykładowej. Rozmieszono w niej cztery przyrządy pomiarowe. Na podstawie otrzymanych wyników omówiono czynniki wpływające na zmienność mierzonych parametrów oraz wyciągnięto wnioski dotyczące lokalizacji oraz ilości przyrządów pomiarowych.
Performing the measurement of temperature and relative humidity of indoor air for the assessment of the internal microclimate of the room is associated with many problems that need to be solved. These include selection of the instruments, their proper location and sufficient number of measuring devices. Each of these aspects reflected in the quality of the information obtained about the air parameters. The article presents the results of measurements of temperature and relative humidity in the lecture hall. In the lecture hall four measurement devices was placed. Based on these results factors affecting the variability of the measured parameters were discussed and the conclusions about location and number of measuring instruments were drown.
Źródło:
Interdyscyplinarne zagadnienia w inżynierii i ochronie środowiska 8; 252-262
9788374939447
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The capability of fungi isolated from moldy dwellings to produce toxins
Autorzy:
Jeżak, Karolina
Kozajda, Anna
Sowiak, Małgorzata
Brzeźnicki, Sławomir
Bonczarowska, Marzena
Szadkowska-Stańczyk, Irena
Powiązania:
https://bibliotekanauki.pl/articles/2168358.pdf
Data publikacji:
2016-07-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
indoor air
mycotoxins
molds
residential environment
sterigmatocystin
roquefortine C
Opis:
Objectives The main objective was analysis and assessment of toxinogenic capabilities of fungi isolated from moldy surfaces in residential rooms in an urban agglomeration situated far from flooded areas in moderate climate zone. Material and Methods The assessment of environmental exposure to mycotoxins was carried out in samples collected from moldy surfaces in form of scrapings and airborne dust from 22 moldy dwellings in winter season. In each sample 2 mycotoxins were analyzed: sterigmatocystin and roquefortine C produced by Aspergillus versicolor and Penicillium chrysogenum, respectively. Mycotoxins were analyzed by high-performance liquid chromatography (HPLC) in: scrapings from moldy surfaces, mixture of all species of fungi cultured from scrapings on microbiological medium (malt extract agar), pure cultures of Aspergillus versicolor and Penicillium chrysogenum cultured from scrapings on microbiological medium; mycotoxins in the indoor air dust were also analyzed. Results The production of sterigmatocystin by individual strains of Aspergillus versicolor cultured on medium was confirmed for 8 of 13 isolated strains ranging 2.1–235.9 μg/g and production of roquefortine C by Penicillium chrysogenum for 4 of 10 strains ranging 12.9–27.6 μg/g. In 11 of 13 samples of the mixture of fungi cultured from scrapings, in which Aspergillus versicolor was found, sterigmatocystin production was at the level of 3.1–1683.2 μg/g, whereas in 3 of 10 samples in which Penicillium chrysogenum occurred, the production of roquefortine C was 0.9–618.9 μg/g. The analysis did not show in any of the tested air dust and scrapings samples the presence of analyzed mycotoxins in the amount exceeding the determination limit. Conclusions The capability of synthesis of sterigmatocystin by Aspergillus versicolor and roquefortine C by Penicillium chrysogenum growing in mixtures of fungi from scrapings and pure cultures in laboratory conditions was confirmed. The absence of mycotoxins in scrapings and air dust samples indicates an insignificant inhalatory exposure to mycotoxins among inhabitants in moldy flats of urban agglomeration situated far from flooded territories. Int J Occup Med Environ Health 2016;29(5):823–836
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2016, 29, 5; 823-836
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Dispersion of Nitrogen Dioxide and Carbon Monoxide in the Indoor Café – Case Study
Autorzy:
Al-Sultan, Ammar A.
Jumaah, Ghufran F.
Al-Ani, Faris H.
Powiązania:
https://bibliotekanauki.pl/articles/124047.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
indoor air pollutants
nitrogen dioxide
carbon monoxide
global standard
smoker
Opis:
A popularity café in Baghdad city was chosen to measure the dispersion of nitrogen dioxide (NO2) and carbon monoxide (CO) as examples of the Indoor Air Pollutants (IAPs) which are considered a significant environmental problem. The aims of this research were, firstly, to measure the variation of NO2 and CO concentrations; secondly, to examine the effect of the seasonal variation of indoor temperature (°C) and relative humidity (%) on the dispersion of both NO2 and CO and finally to compare the results with those of the global standards. The volume of café was about 360 m3 and the number of smokers was about 25-35 smoker/day. This work was divided into two parts where the first part includes the experimental work which comprised the measurement of NO2 and CO by GIGs devices. It was lasted about five months commencing from November 2017 to March 2018 and the readings were taken during two intervals at partial time and during peak time. The second part includes the analysis of obtained results and compared the results of those of the global standards for the Indoor Air Quality suggested by WHO, EPA, and European criteria in order to achieve the goals of this work. The results from this research have highlighted a clear increase in the concentrations of NO2 and CO along with the growing numbers of smokers. Furthermore, the concentrations of NO2 and CO were close to some global standard values of short-term exposure at peak time.
Źródło:
Journal of Ecological Engineering; 2019, 20, 4; 256-261
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diversity of yeast-like fungi and their selected properties in bioaerosol premises utility
Wybrane właściwości grzybów drożdżopodobnych na tle ich różnorodności w bioaerozolu pomieszczeń użyteczności publicznej
Autorzy:
Ejdys, E.
Dynowska, M.
Biedunkiewicz, A.
Sucharzewska, E.
Powiązania:
https://bibliotekanauki.pl/articles/67185.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Botaniczne
Tematy:
diversity
yeast-like fungi
bioaerosol
school building
room
indoor air
Opis:
A total of 69 isolates of yeasts were recorded in the indoor air of the school buildings: 43 in heated rooms and 26 in unheated rooms. Perfect stages prevailed. Fungi isolated in our study belonged to 39 species. These were mostly monospecific isolates although five two-species isolates were noted. Differences in the properties of physiological characters of fungi isolated in both study seasons were observed. As indoor and outdoor air does not mix during the heating season, a specific substrate for prototrophic, non-fermenting yeastlike fungi forms. Acid production allows fungi to dissolve inorganic compounds in building structures and to release needed microcomponents. Abilities to produce carotenoid pigments are clearly promoted in yeast-like fungi living indoor. This may be related to the accumulation of compounds that are indirect stages in the cycle of biosynthesis of carotenoids or a surplus of oxidizing compounds.
Znaczną część biocenozy budynków stanowią trudno wykrywalne grzyby z różnych grup taksonomicznych. U podstawy niepowodzeń w hodowli i izolacji drożdżaków z bioaerozolu wewnętrznego leży zbyt mała wiedza dotycząca ekofizjologii izolatów bytujących w pomieszczeniach. Dlatego celem badań było poznanie niektórych właściwości drożdżaków, ułatwiających im przeżywanie w środowisku pomieszczeń. Materiałem do badań były grzyby drożdżopodobne uzyskane z bioaerozolu 26 pomieszczeń szkolnych o różnym sposobie użytkowania poddanych częściowej modernizacji. Próby pobierano w okresie grzewczym (listopad) i po wyłączeniu ogrzewania (maj). Określano morfologię uzyskanych izolatów grzybów, stadium rozwojowe, zdolności strzępkowania i wytwarzania chlamydospor oraz wybrane cechy biochemiczne: zdolności fermentacyjne, źródła węgla i azotu, przyswajanie witamin, wytwarzanie kwasów oraz zdolności syntezowania barwników. Ogólna liczba grzybów w bioaerozolu badanych pomieszczeń wynosiła wiosną od 314 do 3577 jtk/m 3, natomiast jesienią od 79 do 1533 jtk/m 3 . Z powietrza wewnętrznego w badanych budynkach uzyskano łącznie 69 izolatów drożdży: 43 z pomieszczeń ogrzewanych i 26 z nieogrzewanych. Dominowały stadia doskonałe. Wyizolowane grzyby należały do 39 gatunków. Na ogół izolaty były jednogatunkowe, natomiast w pięciu przypadkach stwierdzono izolaty dwugatunkowe. Zaobserwowano różnice w cechach fizjologicznych grzybów izolowanych w obu sezonach badawczych. Nie mieszanie się powietrza zewnętrznego i wewnętrznego pomieszczeń w okresie grzewczym stwarza specyficzne siedlisko dla prototroficznych, nie fermentujących grzybów droż-dżopodobnych. Produkcja kwasu umożliwia grzybom rozpuszczanie związków nieorganicznych w konstrukcjach budowlanych i uwalnianie potrzebnych mikroskładników. Zdolności wytwarzania barwników karotenoidowych, są wyraźnie promowane u drożdżaków bytujących w pomieszczeniach, co być może wiąże się z nagromadzeniem związków będących pośrednimi etapami w cyklu biosyntezy karotenoidów oraz nadmiarem związków utleniających.
Źródło:
Acta Mycologica; 2014, 49, 1
0001-625X
2353-074X
Pojawia się w:
Acta Mycologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nad występowaniem węgla w powietrzu wewnętrznym wybranych uczelni w Polsce
Research on carbon occurrence in indoor air of selected universities in Poland
Autorzy:
Kociszewska, K.
Rogula-Kopiec, P.
Majewski, G.
Rogula-Kozlowska, W.
Mucha, W.
Mathews, B.
Powiązania:
https://bibliotekanauki.pl/articles/887267.pdf
Data publikacji:
2017
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
Polska
szkoly wyzsze
powietrze wewnetrzne
wegiel organiczny
wegiel elementarny
zawartosc wegla
zanieczyszczenia powietrza
zawartosc pylu drobnego
stezenie zanieczyszczen
Opis:
Badania nad występowaniem węgla w powietrzu wewnętrznym wybranych uczelni w Polsce. Prezentowane badania miały na celu rozpoznanie stężeń submikronowego pyłu (PM1) i związanego z nim węgla organicznego (OC) i elementarnego (EC) w sali wykładowej i tzw. laboratorium studenckim. W pracy omówiono zmienność 24-godzinnych stężeń PM1, OC i EC w obu pomieszczeniach (I, ang. indoor) oraz w powietrzu atmosferycznym (O, ang. outdoor), a także przeanalizowano stosunek I do O. Na przełomie wiosny i lata, niezależnie od lokalizacji (Gliwice – laboratorium studenckie, Warszawa – sala wykładowa), stężenie węgla elementarnego (EC) i organicznego (OC) wewnątrz sal dydaktycznych kształtowała intensywność migracji tych zanieczyszczeń wraz z powietrzem atmosferycznym. Tym samym można uznać, że w żadnym z badanych pomieszczeń dydaktycznych nie występuje istotne źródło OC i EC. Mimo to należy zauważyć, że warunki sprzyjające sorpcji różnych zanieczyszczeń, w tym zwłaszcza związków organicznych tworzących grupę OC na cząstkach pyłu, zmieniają się dynamicznie w czasie i przestrzeni. Wydaje się, że w innym okresie pomiarowym, na przykład w zimie, kiedy wietrzenie sal jest rzadsze a pył atmosferyczny ma inny skład, kumulacja zanieczyszczeń, w tym OC, wewnątrz sal może być większa niż w okresie ciepłym.
Research on carbon occurrence in indoor air of selected universities in Poland. The research presented herein aimed at recognition of submicrone particulate matter concentration as well as organic (OC) and elemental (EC) carbon bound to it in a lecture room and students’ laboratory. The 24-h variability of PM1, OC and EC concentration in both rooms were also discussed along with I : O ratio. In the analysed period – the turn of spring and summer – independent of the location (Gliwice – students’ laboratory, Warsaw – lecture room) the indoor concentration of elemental carbon EC was conditioned by the intensity of those contaminants migration along with atmospheric air. Because of this, it can be concluded that in neither of the rooms there was an important source of OC and EC. However, it should be noted, that conditions favourable for different contaminant sorption, in particular those belonging to OC bound to particulate matter, vary in time and space. It is expected, that for other measurement period – for instance in winter, when rooms are ventilated seldom and PM has different composition, the cummulation of indoor contaminants, including OC, may be higher than for warm period.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2017, 26, 1[75]
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Halotolerance (ionic NaCl) and chaotolerance (ionic MgCl2) of the human pathogen Wallemia mellicola isolated, for the first time, from indoor air in Poland
Autorzy:
Chlebicki, A.
Spisak, W.
Saluga, M.
Powiązania:
https://bibliotekanauki.pl/articles/67298.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Botaniczne
Źródło:
Acta Mycologica; 2018, 53, 1
0001-625X
2353-074X
Pojawia się w:
Acta Mycologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bacterial and Fungal Aerosols in Air-Conditioned Office Buildings in Warsaw, Poland—The Winter Season
Autorzy:
Gołofit-Szymczak, M.
Górny, R. L.
Powiązania:
https://bibliotekanauki.pl/articles/90052.pdf
Data publikacji:
2010
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
indoor air quality
office buildings
bacterial and fungal aerosols
size distribution
Opis:
The microbial quality of the working environment was assessed in winter in air-conditioned office buildings in Warsaw. The average indoor concentrations of bacterial and fungal aerosols were low (<103 cfu∙m–3), below Polish proposals for threshold limit values in public service buildings. Even during cold months, if the air-conditioning system works properly, people remain the main source of bacterial aerosol in offices, whereas infiltration of outdoor air remains a major mechanism responsible for their fungal contamination. An analysis of the bioaerosol size distribution showed that microbial propagules that reach both the upper and lower respiratory tract may evoke numerous adverse health effects from irritation and asthmatic reactions to allergic inflammation. A comparative analysis of viable and total airborne microbial counts showed that viable micro-organisms accounted for up to 0.3% of the total number of microbial propagules. Hence, a comprehensive hygienic assessment of office workplaces should include an efficient control of both these elements.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2010, 16, 4; 465-476
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of integrated indoor environmental air quality parameters in selected church buildings of Faisalabad city: a statistical based comparative study
Autorzy:
Hussain, Zahid
Khan, Mohammad S.
Kundi, Kundi
Alaf, Kashif
Ullah, Yasir
Powiązania:
https://bibliotekanauki.pl/articles/35518580.pdf
Data publikacji:
2021
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
indoor air quality
church buildings
particulate matter
public health
air pollution
Opis:
The objective of this study is to control the air quality parameters for a selected range of different particulate matters. A comprehensive experimental approach is established to regulate the quality of air about a selected range of different air pollutants being investigated in the indoor atmosphere of the church building. Relative humidity, temperature, carbon dioxide, particulate matter and radon were considered as the factors of air quality extents. For establishing the association among the selected parameters, the data were mathematically analyzed. The correlation coefficient confirmed a strong relationship between the indoor CO2 level and the number of public. A negative relationship between the indoor CO2 extent and indoor temperature confirmed that due to the increase in temperature the concentration of CO2 decreased as well. A solid adverse connection among indoor relative humidity and indoor air temperature showed that due to the increase in air temperature, the level of the relative humidity decreased. Some recommendations were proposed for the treatment of air quality in church buildings for human well-being.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2021, 30, 1; 134-147
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies