Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heating temperature" wg kryterium: Wszystkie pola


Tytuł:
A generalized thermoelastic medium subjected to pulsed laser heating via a two-temperature model
Autorzy:
Abouelregal, Ahmed E.
Zenkour, Ashraf M.
Powiązania:
https://bibliotekanauki.pl/articles/949139.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
two-temperature model
thermoelasticity
non-Gaussian laser pulse
laser intensity
Opis:
This article investigates stress and induced temperature in an isotropic, homogeneous, thermoelastic half-space using a two-temperature generalized thermoelasticity model. The bounding plane surface of the present half-space continuum is subjected to a non-Gaussian laser pulse. Laplace’s transform space is considered to deduce a closed-form solution to the problem. In addition, the inversions of Laplace’s transformations have been carried numerically to obtain field quantities in the transient state. The effects of parameters of two-temperature, laser-pulse and laser intensity are investigated. A concluding remark for the graphical forms of the derived expressions is presented.
Źródło:
Journal of Theoretical and Applied Mechanics; 2019, 57, 3; 631-639
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analyzing temperature changes in the ground massif with a horizontal heat exchanger in the course of the heating season
Autorzy:
Adamovsky, R.
Neuberger, P.
Sed'ova, M.
Powiązania:
https://bibliotekanauki.pl/articles/62442.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
temperature change
ground massif
horizontal heat exchanger
heating season
heat pump
ground source heat pump
heat transfer
energy potential
ground temperature
temperature distribution
Opis:
The article is devoted to temperature changes in the ground massif with the horizontal heat exchanger as an energy source for a heat pump. The article was aimed at analyzing temperature changes in the ground massif with the horizontal heat exchanger at the beginning, in the course of and at the end of the heating season. Another aim was to analyze temperature differences in the area of the horizontal exchanger and the reference lot. The heat flow utilized in the evaporator of heat pump was extracted from the ground exchanger (nominal output at the condenser was 10.5 kW). Temperatures of the ground massif with the horizontal heat exchanger were measured in its plane in depths of 0.75 m, 0.5 m and 0.25 m. The temperature inside the ground massif on the reference lot and ambient parameters were measured as well. It is obvious that the difference of energetic potentials inside the ground massif with the heat exchanger and on the reference lot is insignificant at the beginning of the heating season. During the heating season, the difference of ground massif energetic potentials increases; at the end it is constant. The difference of temperatures in horizontal planes was not significant at the beginning of the heating season; however, it gradually increased. Maximum differences were detected in the area of the heat exchanger. In higher strata, the difference between temperatures decreases. During a major part of the heating season, temperatures at pipes of the ground exchanger were negative. This fact affected amounts of heat extracted from the ground massif.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2010, 11
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature changes in heat pump horizontal ground source
Autorzy:
Adamovsky, R.
Neuberger, P.
Sed'ova, M.
Powiązania:
https://bibliotekanauki.pl/articles/60337.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
temperature change
heat pump
ground massif
horizontal heat exchanger
heat potential
soil
thermal potential
heating period
ground temperature
temperature distribution
heat transfer
energy conservation
Opis:
The paper deals with assessment of thermal fields and temperature changes in ground massif with horizontal heat exchanger used as a heat source for a heat pump. Temperatures in the zone of the horizontal ground exchanger are compared with temperatures in a reference land. Changes of heat potential of the soil during the heating period are also assessed. Possibilities of recovery of thermal potential of the ground massif when utilizing vertical and horizontal exchangers are analyzed in the opening part of the paper. The results of the first verification indicated that average temperatures in the horizontal planes of the ground massif did not differ considerably with distance from the exchanger tube. Differences in average temperatures in reference and experimental lands confirmed sufficient heat potential of the ground massif even at the peak of the heating period. The differences in average temperatures reached up to 6.51 K in the end of the heating period while at the beginning of the heating period, the differences in average temperatures dropped to 1.35 K. The differences between maximum and minimum temperatures in the zone of the ground exchanger reached up to 1.9 K at the peak of the heating period and rose to 3.9 K at the beginning and end of the heating period. The first results of our measurements indicate the necessity of accumulation of thermal energy in the soil massif in the summer period like in case of the vertical exchangers.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 07
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element analysis of the 3D thermal stress state in a brake disk
Autorzy:
Adamowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/281459.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
frictional heating
temperature
thermal stresses
pad-disk brake system
finite element method
Opis:
The quasi-static thermal stress state within the linear uncoupled elasticity is studied. The calculations were performed using the finite element method (MSC.Patran/MSC.Nastran). In order to examine smooth stress changes in a brake disk during braking, based on the temperature fields at particular time steps, additionally the script using Python programming language was developed. The numerical three-dimensional FE model of the brake disk for calculation of the transient temperature field was adopted from the previous author’s study. A single braking process at linear deceleration and constant contact pressure was simulated. The evolutions and the contours of the components of the stress tensor as well as the equivalent Huber-Mises stress were examined. The most important aspects of the stress state during braking were discussed.
Źródło:
Journal of Theoretical and Applied Mechanics; 2016, 54, 1; 205-218
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The TRIZ method in determining individual heating costs
Autorzy:
Adamski, Mariusz
Kapalo, Peter
Zhelykh, Vasyl
Voznyak, Orest
Dovbush, Oleksandr
Klymenko, Hanna
Kozydra, Natalia Olcha
Powiązania:
https://bibliotekanauki.pl/articles/2065614.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska
Tematy:
heating costs
technical contradiction
reversed technical contradiction
physical contradiction
temperature
koszty ogrzewania
sprzeczność techniczna
odwrócona sprzeczność techniczna
sprzeczność fizyczna
temperatura
Opis:
The assumptions used in the calculation methods for housing heating costs are described in this paper. The results of calculations are influenced by the values of coefficients related to the location of flats in a building. A technical contradiction, a reversed technical contradiction and a physical contradiction were formulated. Based on the indicated inventive principles, the calculation methods for individual heating costs were analysed.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2020, 9, 1; 127--134
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozkład temperatury podczas mikrofalowego ogrzewania materiału biologicznego
Determination of temperature distribution during microwave heating of biological material
Autorzy:
Araszkiewicz, M.
Kozioł, A.
Powiązania:
https://bibliotekanauki.pl/articles/2071171.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mikrofale
suszenie
światłowody
materiał biologiczny
microwaves
drying
fiber optic
biological material
Opis:
W pracy przedstawiono wyniki pomiarów in situ (przy wykorzystaniu czujników światłowodowych) rozkładu temperatury podczas tradycyjnego (gorącym powietrzem), mikrofalowego i hybrydowego (mikrofale + gorące powietrze) ogrzewania modelowego materiału biologicznego (bulwa ziemniaka). Proces hybrydowy okazał się najlepszy pod kątem równomierności rozkładu temperatury w materiale. W pozostałych przypadkach notowano wysokie różnice temperatury w obrębie ogrzewanej próbki.
Results of in situ measurements (using a fiber optic device) of temperature distributions during traditional (with hot air), microwave and hybrid (microwaves + hot air) heating of model biological material (potatoes) are presented in the paper. The hybrid process appeared to produce the smallest temperature differences inside the material. Other processes led to quite high temperature differences.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 4; 12-13
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena efektu samopodgrzewania układu PLD w niskich temperaturach
Evaluation of self-heating of PLD structure in low temperatures
Autorzy:
Arnold, K.
Pająkowski, J.
Michalak, S.
Powiązania:
https://bibliotekanauki.pl/articles/156501.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
czas propagacji
niskie temperatury
samopodgrzewanie
PLD
propagation delay
low temperature
self-heating
Opis:
W pracy opisano zachowanie programowalnego układu PLD po poddaniu go działaniu niskich temperatur, obniżanych do temperatury ciekłego azotu. Przedstawiono wyniki badań eksperymentalnych, zmierzających do określenia wpływu temperatury i poboru mocy przez wykonaną w technologii CMOS strukturę EE PLD na czasy propagacji zintegrowanych bramek logicznych. Zaprezentowano charakterystyki średniego czasu propagacji pojedynczej bramki w zakresie niskich temperatur i porównano uzyskane wyniki z prognozami, formułowanymi w oparciu o zjawisko samopodgrzewania struktury półprzewodnikowej.
In this paper behavior of a programmable logic device (PLD) in the low temperature range, including temperature of liquid nitrogen, is presented. There are given the results of experiments in which we tried to determine the influence of temperature and power consumption on the propagation delay of integrated logic gates implemented in an EE PLD CMOS structure. The thermal conditions of work resulting from the ambient temperature, clock signal frequency, value of voltage supply and current consumption connected with output loads and switching frequency are discussed. The PLD device properties in the nominal range of ambient temperatures and expected behavior after reducing the temperature are described. The main idea of the circuit for average propagation delay measuring (Fig. 1) and the voltage-current dependence for recommended test output loads (Figs. 2 and 3) are discussed. The test circuit with pull-up resistors for increasing self-heating effect is proposed (Fig. 4). The results for the propagation delay (Fig. 5) and current consumption (Fig. 6) at 1 kHz and 1 MHz switching fre-quency as a function of the temperature changing from -196°C to 20°C are shown. The propagation delay vs. temperature (Figs. 7 and 8) and the current consumption vs. temperature (Fig. 9) for the circuit with external pull-up resistors are presented. The influence of voltage supply value changes on the obtained results is taken into consideration. The results are discussed and compared with expectations.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 7, 7; 641-643
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of heat treatment on microhardness of electroless Ni-YSZ cermet coating
Autorzy:
Bahiyah Baba, N.
Ghazali, A. S.
Abdul Rahman, A. H.
Sharif, S.
Powiązania:
https://bibliotekanauki.pl/articles/2201036.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
Ni-YSZ
cermet
coating
microhardness
heating temperature
heating time
electroless nickel
powłoka
mikrotwardość
temperatura nagrzewania
czas nagrzewania
bezprądowe powlekanie niklem
Opis:
Purpose: The paper discussed the effect of heat treatment on electroless nickel-yttria-stabilised zirconia (Ni-YSZ) cermet coating. Ni-YSZ cermet coating has potential applications such as cutting tools, thermal barriers, solid oxide fuel anode, and various others. The compatibility of ceramic YSZ and metallic nickel in terms of the mechanical properties such as hardness by varying the heating temperature, time and ceramic particle size is highlighted. Design/methodology/approach: Ni-YSZ cermet coating was deposited onto a highspeed steel substrate using the electroless nickel co-deposition method. The temperature and time were varied in a range of 300-400°C and 1-2 hours, respectively. The microhardness measurements were carried out using a Vickers microhardness tester (Shimadzu) according to ISO 6507-4. The surface characterisation of the cermet coating was carried out using JOEL Scanning Electron Microscope (SEM) coupled with Energy Dispersive X-ray (EDX) JSM 7800F. The crystallographic structure of materials was analysed by X-ray diffraction (XRD) Bruker D8 Advance instrument. Findings: It was found that the microhardness of Ni-YSZ cermet coating with the ratio of 70:30, respectively, is directly proportional to the heating temperature and time. Heating the Ni-YSZ cermet coating at 300°C from room temperature (rtp) to 1 hour shows a 12% microhardness increment, while from 1 to 2 hours gives a 19% increment. Compared to heating at 350°C and 400°C, the increment is more significant at 33% and 49% for rtp to 1 hour and 8% and 16% for 1 to 2 hours, respectively. In addition, the effect of varying YSZ particle size in the Ni-YSZ cermet gave response differently for heating temperature and heating time. Research limitations/implications: The paper is only limited to the discussion of the heat treatment effect on Ni-YSZ cermet coating hardness property. The tribological effect will be in future work. Practical implications: The microhardness data may vary due to the Vickers microhardness force applied and the amount of ceramic particle incorporation and phosphorus content in the nickel matrix. Originality/value: The value of this work is the compatibility of the ceramic YSZ and metallic nickel matrix in terms of mechanical properties, such as hardness, upon heat treatment.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2022, 113, 1; 5--12
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The problem of control of rod heating process with nonseparated conditions at intermediate moments of time
Autorzy:
Barseghyan, Vanya R.
Powiązania:
https://bibliotekanauki.pl/articles/1845513.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heating control
temperature
intermediate moments of time
nonseparated multipoint conditions
complete controllability
Opis:
The problem of control of rod heating process by changing the temperature along the rod whose ends are thermally insulated is considered. It is assumed that, along with the classical boundary conditions, nonseparated multipoint intermediate conditions are also given. Using the method of separation of variables and methods of the theory of control of finite-dimensional systems with multipoint intermediate conditions, a constructive approach is proposed to build the sought function of temperature control action. A necessary and sufficient condition is obtained, which the function of the distribution of the rod temperature must satisfy, so that under any feasible initial, nonseparated intermediate, and final conditions, the problem is completely controllable. As an application of the proposed approach, control action with given nonseparated conditions on the values of the rod temperature distribution function at the two intermediate moments of time is constructed.
Źródło:
Archives of Control Sciences; 2021, 31, 3; 481-493
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The problem of control of rod heating process with nonseparated conditions at intermediate moments of time
Autorzy:
Barseghyan, Vanya R.
Powiązania:
https://bibliotekanauki.pl/articles/1845524.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heating control
temperature
intermediate moments of time
nonseparated multipoint conditions
complete controllability
Opis:
The problem of control of rod heating process by changing the temperature along the rod whose ends are thermally insulated is considered. It is assumed that, along with the classical boundary conditions, nonseparated multipoint intermediate conditions are also given. Using the method of separation of variables and methods of the theory of control of finite-dimensional systems with multipoint intermediate conditions, a constructive approach is proposed to build the sought function of temperature control action. A necessary and sufficient condition is obtained, which the function of the distribution of the rod temperature must satisfy, so that under any feasible initial, nonseparated intermediate, and final conditions, the problem is completely controllable. As an application of the proposed approach, control action with given nonseparated conditions on the values of the rod temperature distribution function at the two intermediate moments of time is constructed.
Źródło:
Archives of Control Sciences; 2021, 31, 3; 481-493
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problems associated with the heating up of actuating system of a single-disc lapping machine for flat surfaces
Problematyka nagrzewania się elementów układu wykonawczego docierarki jednotarczowej do płaszczyzn
Autorzy:
Barylski, Adam
Powiązania:
https://bibliotekanauki.pl/articles/31232926.pdf
Data publikacji:
2022
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
mechanical engineering
assembly technologies
lapping
temperature
analysis
inżynieria mechaniczna
technologie montażowe
docieranie
temperatura
analiza
Opis:
The paper presents the results of the examination of the heating up of the basic elements of the actuating system of a single-disc lapping machine with standard kinematics, intended for machining flat surfaces. The increase of the temperature of the drive assembly, rollers and separator guide ring, as well as the lapping disc and machined elements were analysed. Heating up of the machining system was examined during the machining of a cast iron tool and flat surface lapping. Lapping is one of the methods of abrasive machining applied during the individual fitting of elements in assembly or when a technological compensator is used. The increase of temperature in the machining system influences, among others, the dimensional accuracy of lapped metal elements.
Przedstawiono wyniki badań nagrzewania się podstawowych elementów układu wykonawczego docierarki jednotarczowej o standardowej kinematyce do obróbki powierzchni płaskich. Analizowano przyrost temperatury zespołu napędowego, rolek i pierścieni prowadzących separatory oraz tarczy docierającej i obrabianych elementów. Badano nagrzewanie się układu obróbkowego podczas wyrównywania żeliwnego narzędzia i docierania powierzchni płaskich. Docieranie jest jedną z metod obróbki ściernej stosowaną podczas indywidualnego dopasowywania elementów w montażu lub przy wykorzystaniu kompensatora technologicznego. Przyrost temperatury w układzie obróbkowym ma między innymi wpływ na dokładność wymiarową docieranych elementów metalowych.
Źródło:
Technologia i Automatyzacja Montażu; 2022, 3; 18-27
2450-8217
Pojawia się w:
Technologia i Automatyzacja Montażu
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmienności temperatur w obiekcie doświadczalnym eksploatowanym z osłabieniem nocnym
Analysis of temperature variation in experimental building operating with night setback
Autorzy:
Basińska, M.
Koczyk, H.
Powiązania:
https://bibliotekanauki.pl/articles/362428.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
fizyka budowli
regulacja pogodowa
regulacja jakościowa instalacji centralnego ogrzewania
building physics
central heating
Opis:
W artykule przedstawiono analizę zmienności temperatur wewnętrznych w pomieszczeniach budynku do- świadczalnego. Badano wpływ parametrów regulacji pogodowej na wybrane temperatury wewnętrzne. W czasie 3-tygodniowego okresu pomiarowego przeanalizowano 4-warianty nastawy regulatora. Analizy prowadziły do oceny jakości regulacji i utrzymania komfortu cieplnego.
Analysis of the variation of indoor and wall temperatures in the experimental building was presented. The effect of four different settings on weather-controlled control unit was monitored. Results obtained during three week research were used to assess regulation and thermal comfort quality.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 21-24
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the heat insulation layer on the thermally stressed condition of the facade wall
Autorzy:
Basok, Borys
Davydenko, Borys
Koshlak, Hanna
Lysenko, Oksana
Powiązania:
https://bibliotekanauki.pl/articles/26079345.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
stres temperaturowy
betonowa ściana elewacyjna
system grzewczy
modelowanie numeryczne
warstwa termoizolacyjna
temperature stress
concrete facade wall
heating system
numerical modelling
heat-insulating layer
Opis:
The temperature-stress state of the concrete facade wall with a window opening, which is the external enclosing structure of the room with a steel heating device, was investigated by the method of numerical modeling. Estimated studies were performed for winter period when the heating system of the building is functioning. According to the results of solving the system of equations of thermal stress and equation of thermal conductivity, the temperature distribution over the wall volume and distribution of normal and tangential stresses were determined. Areas of the wall where these stresses are maximum were identified. The research was performed for cases of both, absence and presence of a heat-insulating layer on the outer surface of the facade wall. From comparison of the results obtained for these two options, it follows that the external thermal insulation coating not only helps to reduce dissipative heat loss through the facade wall, but also reduces the absolute values of stresses in the concrete wall arising resulting from temperature deformations. In some cases, the sign of stresses changes from stretching (wall without external insulation) to compressive (wall with insulation).
Źródło:
Production Engineering Archives; 2022, 28, 2; 123--131
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy płytowego fundamentu grzewczego
Work analysis of the plate heating foundation
Autorzy:
Belok, J
Wilk-Słomka, B
Powiązania:
https://bibliotekanauki.pl/articles/362697.pdf
Data publikacji:
2011
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
płytowy fundament grzewczy
powietrzne ogrzewanie podłogowe
ESP-r
prąd dwutaryfowy
idealny rozkład temperatury w pomieszczeniu
plate heating foundation
air floor heating
current tariff level
ideal temperature distribution
Opis:
W artykule przeanalizowano możliwości zastosowania płytowego fundamentu grzewczego z powietrznym ogrzewaniem podłogowym [5] w budynku jednorodzinnym. Rozpatrywano warianty zapewniające uzyskanie komfortu cieplnego, projektowej temperatury powietrza w pomieszczeniu, obliczeniowego zapotrzebowania na ciepło dla budynku, przy zastosowaniu do ogrzewania pomieszczenia nagrzewnicy elektrycznej oraz zadanej grubości fundamentu.
In the article possibilities of using the plate heating foundation with the air floor heating [5] at the single-family building were analysed. Variants guaranteeing obtaining thermal comfort, design air temperature in the room, computational demand for the heating of building, at applying the electric and set stove for heating air up thicknesses of the foundation were being considered.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2011, T. 6, nr 4, 4; 9-14
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie odnawialnych źródeł energii i ciepła odpadowego w niskotemperaturowym systemie ogrzewczo-chłodzącym hali drukarni
Low temperature heating systems for production halls with use of renewable energy sources
Autorzy:
Bialik, W.
Gil, S.
Machulec, B.
Ochman, J.
Powiązania:
https://bibliotekanauki.pl/articles/105199.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
systemy ogrzewania
oszczędność energii
pompy ciepła
mata grzejna
pasywny system chłodzenia
heating systems
energy saving
heat pumps
heating mat
passive cooling system
Opis:
W pracy przedstawiono nowoczesny system ogrzewania hali drukarni oraz pomieszczeń biurowych i socjalnych. Został on zaprezentowany na dwóch schematach oraz omówiony w pierwszej części artykułu. Układ wykorzystuje pompy ciepła ciecz-ciecz oraz powietrze ciecz. Dla pomp ciecz-ciecz dolnym źródłem jest pionowy wymiennik gruntowy składający się z 13 otworów o głębokości 100 m. W opisywanym rozwiązaniu zastosowano także poziomy gruntowy wymiennik ciepła do ogrzewania czerpanego z otoczenia powietrza wentylacyjnego płynącego następnie do rekuperatorów pomieszczeń biurowych i socjalnych. Gruntowe wymienniki ciepła w trakcie ich budowy zostały zaprezentowane na jednym z rysunków. Pomieszczenia biurowe i socjalne ogrzewane lub schładzane są medium płynącym w matach umieszczonych w ścianach oraz w wybranych częściach podłogi. Dla ograniczenia strat ciepła związanych z wentylacją w instalacji zastosowano trzy układy rekuperacji (osobno dla pomieszczeń biurowych, socjalnych i hali drukarskiej). Poprawne działanie systemu zobrazowano w postaci wykresu zmian temperatur we wspomnianych pomieszczeniach. Dla największej centrali wentylacyjnej zamieszczono też przebieg temperatur strumieni powietrza dla wybranych dni. W podsumowaniu zawarto wnioski płynące z dotychczasowej eksploatacji oraz plany dalszego rozwoju systemu.
The paper presents a modern heating system of the printing hall, offices and social services. It was presented on two diagrams and discussed in the first part of the article. System utilizes the heat pumps of liquid-liquid and liquid air. For pumps of liquid-liquid the lower source is vertical ground heat exchanger, consisting of 13 holes having a depth of 100 m. In the described solution also been used horizontal ground heat exchanger to heat which has been taken from the environment of ventilation air flowing then to the recuperators of offices and social rooms. Ground heat exchangers during their construction are presented in one of the drawings. Office and social rooms are heated (or cooled) by medium flowing in the wall mats and in selected parts of a floor. To limit the heat loss associated with the ventilation in the system has been uses three sets of the recuperation (separately for offices, social rooms and printing hall). Correct system operation is illustrated in the graph of temperature changes in these rooms. The summary contains conclusions from current exploitation and plans for further development of the system.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 1; 461-468
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies