Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heating plant" wg kryterium: Wszystkie pola


Tytuł:
Accumulation of elements in vegetation spontaneously developing on self-heating waste dumps in the Upper Silesia area (Poland)
Autorzy:
Wojewódka-Przybył, Marta
Stienss, Jacek
Kruszewski, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2201191.pdf
Data publikacji:
2022
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
toxic metals
burning heaps
environment contamination
coal
smelting waste
plant hyperaccumulation
element translocation
Opis:
Accumulation of 34 trace and major elements was analysed in 9 plant species (Tussilago farfara, Arctium tomentosum, Solidago canadensis, Populus L., Eupatorium cannabinum, Verbascum sp., Solanum nigrum, Rumex crispus L., Betula pendula) and one fungus (Schizophyllum commune) collected from coal, PbZn-smelting, and mixed-type waste heaps in Upper Silesia (Poland). The most persistent and extreme enrichment was found in the burnt bark of Betula pendula from Bytom. Enrichment factors in relation to the geometric mean of elevated (PE) and hyperaccumulator (PH) plant contents show extreme values for elements toxic to vegetation, such as Zn (EFPE up to 13, EFPH up to 17), Pb (EFPH up to 4, EFPE up to 161), Tl (EFPE up to 8), Cd (EFmax of 327), Hg (EFPH up to 3), and Ag (maximum EFPE of 14). Elevated are also V (EFPN up to 13), Sc (EFPN up to 14), Ni (EFPN up to 17), Se (EFPN up to 16), Fe (EFPN up to 48), Co (EFPN up to 23), Sb (EFPN up to 31), and Bi (EFPN up to 34). Although the levels of the elements studied were usually below potentially toxic levels, they were often above the normal ones. Furthermore, significant differences in the contents between different plant tissues were observed, as reflected in the translocation factor (TF). Verbascum sp. and S. nigrum accumulate such elements mostly in their above-ground tissues, and may thus be considered useful in phytoextraction of Zn, Pb and other elements. Sl. canadensis and E. cannabinum mostly display the opposite strategy, with element immobilization in their roots. Extreme Zn contents in E. cannabinum, peaking in its roots, suggest it to be a potential Zn phytostabilizer.
Źródło:
Geological Quarterly; 2022, 66, 3; art. no. 30
1641-7291
Pojawia się w:
Geological Quarterly
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorption Kinetics of Reactive Dyes on Ash from Town Heating Plant
Autorzy:
Djordjevic, D.
Stojiljkovic, D.
Smelcerovic, M.
Powiązania:
https://bibliotekanauki.pl/articles/205104.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kinetics
reactive dye
adsorption
ashes
Opis:
In order to investigate the mechanism of adsorption of reactive dyes from the textile industry on ash from heating plant produced by brown coal combustion, some characteristic sorption constants are determined using Langergren adsorption equations for pseudo-first and pseudo-second order. Combined kinetic models of pseudo-first order and pseudo-second order can provide a simple but satisfactory explanation of the adsorption process for a reactive dye. According to the characteristic diagrams and results of adsorption kinetic parameters of reactive dyes on ashes, for the applied amounts of the adsorbents and different initial dye concentrations, it can be concluded that the rate of sorption is fully functionally described by second order adsorption model. According to the results, the rate constant of pseudo-second order decreases with increasing initial dye concentration and increases with increasing amount of adsorbent – ash.
Źródło:
Archives of Environmental Protection; 2014, 40, 3; 123-135
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości zwiększenia chłonności otworów zatłaczających na przykładzie ciepłowni geotermalnej w Pyrzycach
Analysis of the possibility of increasing the absorption capacity of injection openings on the example of a geothermal heating plant in Pyrzyce
Autorzy:
Noga, B.
Kosma, Z.
Zieliński, J.
Powiązania:
https://bibliotekanauki.pl/articles/203824.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
geotermia
ciepłownia geotermalna
otwory chłonne
zatłaczanie
kolmatacja
geothermal energy
geothermal heating
absorbers
injection
plugging
Opis:
W prezentowanej pracy została przeanalizowana chłonność otworów zatłaczających w ciepłowni geotermalnej w Pyrzycach. Możliwości chłonne dwóch otworów wynosiły 340 m3/h wody przy ciśnieniu około 4 barów. W bardzo krótkim czasie wydajność ta zmniejszyła się do około 60 m3/h przy ciśnieniu zatłaczania nierzadko przekraczającym 12 barów. Taka sytuacja utrzymywała się przez okres około 20 lat. Próby poprawy chłonności były krótkotrwałe i nie miały wpływu na poprawę sprawności działania otworów chłonnych. Dopiero prace przeprowadzone w 2016 roku doprowadziły do uzyskania długotrwałej efektywnej pracy otworu chłonnego Pyrzyce GT-2. W ramach zabiegów rekonstrukcyjnych uzyskano wydajność zatłaczania 130 m3/h do jednego otworu przy ciśnieniu nieprzekraczającym 7 barów. Uzyskany efekt utrzymywany był na niemal stałym poziomie przez ponad dwa lata poprzez stosowanie różnych preparatów chemicznych dozowanych do zatłaczanej wody termalnej. Przeprowadzone badania przyczyniły się do zwiększenia sprawności pracy ciepłowni geotermalnej w Pyrzycach.
As part of the work presented, the absorption capacity of the injection boreholes in the geothermal heat plant in Pyrzyce was analyzed. The absorption capacity of two wells was 340 m3/h at the pressure of about 4 bar. In a very short time this efficiency decreased to around 60 m3/h at the injection pressure frequently exceeding 12 bar. This situation lasted for about 20 years. Attempts to improve the absorbency were short-lived and did not improve the efficiency of the lymphatic openings. It was not until 2016 that the Pyrzyce GT-2 lymphatic bore was effectively drilled for a long time that the reconstructions achieved an injection rate of 130 m3/h into one bore at a pressure not exceeding 7 bar. The effect obtained was kept almost constant for over two years through the use of various chemical preparations dosed into the injected thermal water. The conducted research contributed to increasing the efficiency of the operation of the geothermal heating plant in Pyrzyce.
Źródło:
Technika Poszukiwań Geologicznych; 2018, R. 57, nr 2, 2; 135-154
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu nowych środków kondycjonujących wodę termalną na działanie geotermii Pyrzyce
Analysis of impact a new conditioning chemicals of thermal water on performance geothermal heating plant in Pyrzyce
Autorzy:
Noga, B.
Mazur, M.
Kosma, Z.
Powiązania:
https://bibliotekanauki.pl/articles/317020.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
kondycjonowanie wody termalnej
chemiczne kondycjonowanie
instalacje geotermalne
kolmatacja
conditioning of thermal water
chemical conditioning
geothermal installation
clogging
Opis:
W artykule zostały omówione badania nowych metod kondycjonowania wody termalnej, które zostały wykonane na instalacji geotermalnej w Pyrzycach. Wytypowane w badaniach laboratoryjnych środki chemiczne do kondycjonowania wody termalnej były w pierwszym etapie testowane na bocznym rurociągu na prasce ciśnieniowej, a następnie w warunkach przemysłowych podczas normalnej pracy ciepłowni.
Paper discussed investigation a new methods of conditioning thermal water by chemicals, that performed on a geothermal heating plant in Pyrzyce. The chemicals tested in the first phase were tested on a lateral pipeline and then under industrial conditions during normal operation of the geothermal heating plant.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 320-323, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of heat load in a biomass-fired boiler
Analiza obciążenia cieplnego w kotle opalanym biomasą
Autorzy:
Bartoszewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/172829.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biomasa
ciepłownia
kocioł ciepłowniczy
biomass
heat-generating plant
heating boiler
Opis:
This paper discusses an exemplary cooperation between a research center, industry and technical inspection authorities. The purpose of the investigations (carried out to find the failure of a biomass-fired boiler in a heating plant) is an analysis of the effect of operating water boiler conditions on the heat load of the heating surface. The analysis concerns the reasons for failure of the membrane heat exchanger of the water-gas type being a basic heating surface of the boiler burning biomass. During the operation of the boiler some cracks perforated the bottom and smoke tube endings occurred.
W artykule przedstawiono wyniki współpracy ośrodka naukowego, ciepłowni miejskiej i inspekcji technicznej realizowanych w celu wykrycia przyczyn awarii kotła opalanego biomasą. Przedstawiono wyniki analizy numerycznej oraz wizualizacji w ciepłowni w celu określenia tych przyczyn. Badania obejmowały analizę przepony wymiennika ciepła typu woda-spaliny, który stanowi podstawową powierzchnię wymiany ciepła w kotle spalającym biomasę. Przedstawione w pracy wnioski z analizy wskazują na przyczyny pęknięć płyty sitowej i końcówek płomieniówek wymiennika.
Źródło:
Archiwum Energetyki; 2011, 41, 1; 65-77
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing the Solar Power Plant Efficiency Degradation Resulting from Heating
Autorzy:
Lavrik, A.
Yakovleva, E.
Lеskov, A.
Powiązania:
https://bibliotekanauki.pl/articles/124651.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
photoelectric module
PEM
solar power plant
performance coefficient
heating
cooling
Opis:
Renewable power sources (RPS) play an ever growing role in power production. With the green power cost decreasing, the RPS share (including hydro power plants) in power production grows fast. Using RPS in supplying power to various facilities reduces the CO2 emission into atmosphere, thus reducing the greenhouse effect and being a fundamental factor in fighting the global warming. Every type of RPS possesses certain drawbacks that need to be eliminated. RPS units do have disadvantages, too, including low efficiency coefficient, and low specific power. However, there is the need for specific technological conditions. The present work describes the issue of photoelectric module heating. Photoelectric module heating results in both lower output voltage and module aging acceleration. The present work offers the method for assessing the practicability of development and implementation of solar power cell module active cooling systems, based on the photoelectric module daily performance schedules, drawing on statistic meteorological data collected over many years, and also it presents the brief description of various methods for cooling photoelectric modules.
Źródło:
Journal of Ecological Engineering; 2018, 19, 3; 115-119
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of district heating needs and technical possibilities in the vicinity of a future polish nuclear power station
Autorzy:
Cholewiński, M.
Tomków, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/1189974.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
elektrownia jądrowa
kogeneracja
system ciepłowniczy
popyt na ciepło
nuclear power plant
cogeneration
district heating system
pressurised water reactor
heat demand
Opis:
Nuclear power plants can be a reliable source of heat supplying district heating systems. Importantly, thermal and flow parameters of a secondary loop in pressurized water reactor technologies are sufficient to supply a district heating networks. Therefore, NCHP (Nuclear Combined Heat and Power) systems seem to be a viable replacement for traditional coal-fired cogeneration units located in big cities and may contribute to environmental protection in both local and international scale. In this paper working conditions of a municipal heat network, such as a pressure drop and the heat loses, were calculated and adapted to expected Poland’s first nuclear power plant located in Pomerania Province. Cumulative probability distribution model of heat generation power in metropolitan area and future heat demand have been created and used to identify optimal size of NCHP heat output. Main parameters of heating network were presented and discussed. The positive effects on environment were assessed and summarized as well.
Źródło:
Interdisciplinary Journal of Engineering Sciences; 2017, 5, 1; 1--10
2300-5874
Pojawia się w:
Interdisciplinary Journal of Engineering Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics of pellets made from different plant materials
Charakterystyka peletów wykonanych z różnych materiałów roślinnych
Autorzy:
Jachniak, E.
Holubčik, M.
Powiązania:
https://bibliotekanauki.pl/articles/126573.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
pellets
total heating value
biomass
pelety
ciepło spalania
biomasa
Opis:
The aim of this research was estimation of the characteristic properties (energy and qualitative) of pellets, which were made from different plant biomass. In this research the spruce wood sawdust pellets, straw wheat pellets, straw rape pellets and hay pellets (produced in a large scale companies) were used. In addition, in this research the same kinds of these pellets were used, but produced in domestic conditions. The analyses were conducted in the laboratory of the Faculty of Mechanical Engineering University of Žilina, in February 2014. The following parameters were analyzed: moisture content, total heating value (calorimeter LECO AC 500 was used) and calorific value. The aim of the qualitative evaluation of these pellets, water test was conducted and mechanical durability was estimated. The research indicated that the spruce wood sawdust pellets and straw rape pellets (produced in a large scale companies) were characterized the lowest moisture content (respectively 6.88 and 6.91%) (this is main parameter, which influences on energetic value of pellets) and the highest values of total heat (respectively 20.16 and 18.65 MJ/kg). The highest content of moisture and the lowest energetic value characterized the every pellets, which were produced in domestic mill.
Celem badań była ocena charakterystycznych (energetycznych i jakościowych) właściwości peletów, wykonanych z różnorodnej biomasy roślinnej. W badaniach wykorzystano: pelety wykonane z trocin drzewnych świerkowych, słomy pszenicznej, słomy rzepakowej oraz z siana (produkowane w dużych firmach). Dodatkowo w badaniach tych wykorzystano te same rodzaje peletów, ale produkowanych w warunkach eksperymentalnych. Analizy prowadzono w laboratorium Katedry Techniki Energetycznej Uniwersytetu Żylińskiego w Żylinie w lutym 2014 r. Brano pod uwagę następujące parametry: zawartość wilgotności, ciepło spalania (wykorzystano kalorymetr LECO AC 500) oraz wartość opałową. W celu oceny jakościowej badanych peletów przeprowadzono także test wodny oraz zbadano ich mechaniczną wytrzymałość. Badania wykazały, że najniższą wilgotnością (główny parametr wpływający na wartość energetyczną peletów) charakteryzowały się pelety wykonane z trocin drzewnych świerkowych oraz słomy rzepakowej (odpowiednio 6,88 i 6,91%) (ale produkowanych na dużą skalę w wielkich firmach) i uzyskały też najwyższą wartość ciepła spalania (odpowiednio 20,16 i 18,65 MJ/kg). Najwyższą zawartością wilgotności i najniższymi energetycznymi właściwościami cechowały się wszystkie pelety, które były produkowane w warunkach eksperymentalnych.
Źródło:
Proceedings of ECOpole; 2015, 9, 1; 95-101
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of optimum heating and cooling degree-hour values for pepper plant
Autorzy:
Atilgan, A.
Yucel, A.
Tanriverdi, C.
Oz, H.
Tezcan, A.
Powiązania:
https://bibliotekanauki.pl/articles/101263.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
cooling
degree-hour
heating
Kumluca
Opis:
Information on the energy needs of agricultural production activities carried out in any region can be obtained in advance. Many methods are used for this purpose. One of them is a degree-hour method. Kumluca district of Antalya province where pepper cultivation is done intensively was chosen as a study area. The growers prefer autumn production of pepper plants inside the greenhouses in this region. Production starts in early October and last until June. The long-term (1960-2015) thermometer temperatures in the study area were obtained from the Turkish State Meteorological Service. In this study, by using only meteorological data, during each growing season (planting, flowering, pollination, fruit ripening and harvesting) were obtained degree-hour values for the pepper plant and evaluated with Student-t test. Regression coefficients were obtained by correlating heating and cooling degree-hour values with different temperature values which are recommended during the vegetative growing season for the pepper plant. Regression analysis was performed between obtaining heating and cooling degree-hour values (dependent variable) and annual mean heating and cooling degree hour values (independent variable) which are suggested basic temperature values. In conclusion, the regression coefficients were determined as 0.99 for out of greenhouse heating degree-hour and as 0.90-0.99 for cooling degree-hour, respectively. Heating and cooling-hour values were found between 0.96-0.88 and 0.99-0.87, respectively. It was determined that there are very high correlations in the positive direction. According to different growing seasons of pepper, knowing how much less or more of heating and cooling degree-hour values is needed, one can give information in advance in terms of energy consumption or usage. Areas or regions where less energy is to be used can be determined in terms of agricultural production to be done in any region.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2017, II/1; 457-467
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of heating on antioxidative activity of rapeseed and evening primrose extracts
Autorzy:
Zadernowski, R.
Nowak-Polakowska, H.
Konopka, I.
Powiązania:
https://bibliotekanauki.pl/articles/1372684.pdf
Data publikacji:
1996
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
evening primrose
Oenothera biennis
heating
food technology
methanolic extract
natural antioxidant
plant oil
polyphenol
antioxidant activity
phenolic acid
plant
rapeseed
Opis:
The composition and effect of heating (60°-110°C) on antioxidative activity in plant oil of rapeseed (RE) and evening primrose (EPE) methanolic extracts were studied. Different phenolics characterized the extracts. The EPE contained about 10-fold higher amount of phenolics (862.2 g/kg extract) than RE; flavanols (683.8 g/kg) and proanthocyanidins (760.1 g/kg) prevailed in the former and phenolic acid derivatives in the latter. The phenolic compounds of both extracts differed with the fenolic acids composition. Sinapic acid prevailed in rapeseed phenolics and protocatechic and gentisic acids in evening primrose phenolics. Both extracts had generally similar antioxidative activity in the temperature ranging from 60°C to 80°C with the oil peroxide values from 3.5 mmol O/kg to 5.0 mmol O/kg compared to the range of 6.0-7.0 mmol O/kg in control oils. The temperatures above 80°C decreased the antioxidative activity of both extracts and even made them to be prooxidative.
Badano skład i wpływ temperatury (60-110°C) na właściwości przeciwutleniające ekstraktów metanolowych nasion rzepaku i wiesiołka. Stwierdzono, że olej tych nasion zawierał tokoferole, głównie α- i y-, w ilości 0,65 g/kg (rzepak) i 0,45 g/kg (wiesiołek) (tab. 1), a ekstrakty metanolowe nasion charakteryzowały się różnymi formami związków fenolowych. W porównaniu z ekstraktem rzepakowym, ekstrakt wiesiołka zawierał około 10-krotnie więcej związków fenolowych, wśród których dominowały flawanole i proantocyjanidyny (tab. 2). Kwasy fenolowe i ich pochodne dominowały w ekstrakcie rzepakowym. Związki fenolowe ekstraktów różniły się składem kwasów fenolowych (rys. 1). Ekstrakty metanolowe obu nasion wykazywały się generalnie taką samą aktywnością przeciwutleniającą (rys. 2). W temperaturze powyżej 80°C aktywność przeciwutleniająca ekstraktów zanikała lub nawet obserwowano przyśpieszenie procesu utleniania oleju roślinnego.
Źródło:
Polish Journal of Food and Nutrition Sciences; 1996, 05, 2; 13-21
1230-0322
2083-6007
Pojawia się w:
Polish Journal of Food and Nutrition Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental and economic assessment of a biomass-based cogeneration plant: Polish case study
Analiza ekologiczna i ekonomiczna układu skojarzonego zasilanego biomasą: studium przypadku dla Polski
Autorzy:
Mateusz, Świerzewski
Paweł, Gładysz
Powiązania:
https://bibliotekanauki.pl/articles/461263.pdf
Data publikacji:
2017-12
Wydawca:
Mazowieckie Biuro Planowania Regionalnego w Warszawie
Tematy:
biomasa
skojarzone wytwarzanie ciepła i energii elektrycznej
kogeneracja
miejska sieć ciepłownicza
współczynnik udziału skojarzenia
biomass
combined heat and power generation
cogeneration
district heating system
coefficient of the share of cogeneration
Opis:
The goal of the paper is to presents the results of the energy, economic and environmental assessment of biomassfired combined heat and power (BCHP) units cooperating with the district heating system. The mathematical models of both considered BCHP units (with back-pressure and extraction-condensing turbines) have been elaborated and validated with the data from commercially available CHP units. The results of this study prove that BCHP units can be a good option for the Polish energy sector, both from an environmental and energy point of view. The economic analysis showed that the analysed BCHP units could be profitable, but the are several factors, like prices of guarantees of origin for electricity producted from renewable energy sources, that strongly affect the results.
W artykule zaprezentowano wyniki analizy energetycznej, ekonomicznej oraz ekologicznej elektrociepłowni pracującej w miejskim systemie ciepłowniczym. Modele matematyczne rozważanych wariantów elektrociepłowni (z turbiną przeciwprężną oraz turbiną kondensacyjną) zostały opracowane i zweryfikowane na podstawie dostępnych danych z jednostek kogeneracyjnych. Otrzymane wyniki wskazują, że biomasowe układy kogeneracyjne mogą stanowić dobrą alternatywę dla polskiego sektora energetycznego, zarówno z ekologicznego jak i energetycznego punktu widzenia. Analiza ekonomiczna wskazała, że analizowane warianty elektrociepłowni mogą być opłacalne lecz takie czynniki jak cena za świadectwa pochodzenia produkcji energii ze źródeł odnawialnych mogą znacząco wpłynąć na uzyskane wyniki.
Źródło:
MAZOWSZE Studia Regionalne; 2017, 22; 97-114
1689-4774
Pojawia się w:
MAZOWSZE Studia Regionalne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heating value of seeds of leguminous plants and their mixes with seeds of tussock-grass subfamily cereals
Ciepło spalania nasion roślin strączkowych i ich mieszanek z ziarniakami zbóż z podrodziny wiechlinowatych
Autorzy:
Wcislo, G.
Zabinski, A.
Sadowska, U.
Powiązania:
https://bibliotekanauki.pl/articles/792621.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
leguminous plant
seed
cereal seed
combustion heat
heating value
yellow lupin
pea seed
plant biomass
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2013, 13, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of risk factors related to the production and use of alternative fuels
Identyfikacja czynników ryzyka związanych z wytwarzaniem i wykorzystaniem paliw alternatywnych
Autorzy:
Ivashchuk, Oleksandr
Łamasz, Bartosz
Iwaszczuk, Natalia
Powiązania:
https://bibliotekanauki.pl/articles/282893.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
waste
energy recovery
alternative fuel
risk
combined heat and power plant
heating plant
electricity and heat
odpad
odzysk energii
paliwo alternatywne
ryzyko
elektrociepłownia
ciepłownia
energia elektryczna i cieplna
Opis:
The article analyzes the risk factors related to the energy use of alternative fuels from waste. The essence of risk and its impact on economic activity in the area of waste management were discussed. Then, a risk assessment, on the example of waste fractions used for the production of alternative fuel, was carried out. In addition, the benefits for the society and the environment from the processing of alternative fuels for energy purposes, including, among others: reducing the cost of waste disposal, limiting the negative impact on water, soil and air, reducing the amount of waste deposited, acquisition of land; reduction of the greenhouse effect, facilitating the recycling of other fractions, recovery of electricity and heat, and saving conventional energy carriers, were determined. The analysis of risk factors is carried out separately for plants processing waste for alternative fuel production and plants producing energy from this type of fuel. Waste processing plants should pay attention to investment, market (price, interest rate, and currency), business climate, political, and legal risks, as well as weather, seasonal, logistic, technological, and loss of profitability or bankruptcy risks. Similar risks are observed in the case of energy companies, as they operate in the same external environment. Moreover, internal risks may be similar; however, the specific nature of the operation of each enterprise should be taken into account. Energy companies should pay particular attention to the various types of costs that may threaten the stability of operation, especially in the case of regulated energy prices. The risk associated with the inadequate quality of the supplied and stored fuels is important. This risk may disrupt the technological process and reduce the plant’s operational efficiency. Heating plants and combined heat and power plants should also not underestimate the non-catastrophic weather risk, which may lead to a decrease in heat demand and a reduction in business revenues. A comprehensive approach to risk should protect enterprises against possible losses due to various types of threats, including both external and internal threats.
W artykule dokonano analizy czynników ryzyka związanego z energetycznym wykorzystaniem paliw alternatywnych produkowanych na bazie odpadów. Omówiono kwestie istoty ryzyka oraz jego wpływu na działalność gospodarczą w obszarze zagospodarowania odpadów. Następnie dokonano oceny ryzyka na przykładzie frakcji odpadów stosowanych do produkcji paliwa alternatywnego. Wskazano również korzyści, jakie przynosi społeczeństwu i środowisku przetwarzanie ich w celach energetycznych, w tym m.in.: obniżenie kosztów unieszkodliwiania odpadów; ograniczenie negatywnego wpływu na wody, glebę i powietrze; zmniejszenie ilości i wielkości składowanych odpadów; pozyskanie terenów; zmniejszenie efektu cieplarnianego; ułatwienie recyklingu pozostałych frakcji; odzysk energii elektrycznej i cieplnej; oszczędność konwencjonalnych nośników energii. Analiza czynników ryzyka jest przeprowadzona oddzielnie dla zakładów przetwarzających odpady na paliwa alternatywne oraz zakładów wytwarzających energię z tego rodzaju paliw. Zakłady przetwarzające odpady powinny zwrócić uwagę na ryzyko inwestycyjne, rynkowe (cenowe, stopy procentowej, walutowe), koniunkturalne, polityczno-prawne i społeczne, a także ryzyko: pogodowe, sezonowe, logistyczne, technologiczne, utraty rentowności czy upadłości. Podobne ryzyka występują też w działalności zakładów energetycznych, ponieważ funkcjonują one w tym samym otoczeniu zewnętrznym. Również ryzyka o pochodzeniu wewnętrznym mogą być podobne, jednak należy uwzględniać specyfikę działalności każdego zakładu. W przedsiębiorstwach energetycznych szczególną uwagę należy zwrócić na zwiększenie różnego rodzaju kosztów, które może zagrozić stabilności funkcjonowania, zwłaszcza w sytuacji regulowanych cen energii. Ważne jest ryzyko związane z nieodpowiednią jakością dostarczanych i przechowywanych paliw, które może zakłócić proces technologiczny i zmniejszyć wydajność pracy zakładu. Ciepłownie i elektrociepłownie nie powinny też bagatelizować ryzyka pogodowego niekatastroficznego, którego konsekwencją jest spadek popytu na ciepło i zmniejszenie wpływów z działalności gospodarczej. Kompleksowe podejście do ryzyka powinno uchronić przedsiębiorstwa przed ewentualnymi stratami z tytułu różnego rodzaju zagrożeń, płynących zarówno z otoczenia zewnętrznego, jak i tkwiących wewnątrz zakładów produkcyjnych.
Źródło:
Polityka Energetyczna; 2019, 22, 1; 97-112
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Industrial Use of Geothermal Energy in Poland Based on the Example of a Geothermal Heating Plant in Bańska Niżna
Przemysłowe wykorzystanie energii geotermalnej w Polsce na przykładzie geotermalnego zakładu ciepłowniczego w Bańskiej Niżnej
Autorzy:
Sala, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/438907.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Pedagogiczny im. Komisji Edukacji Narodowej w Krakowie
Tematy:
geothermic; industry
production
renewable energy
sustainable development
energetyka odnawialna
geotermia
produkcja
przemysł
rozwój zrównoważony
Opis:
Geothermal energy can be an interesting source of renewable energy in many respects. Among its numerous uses, industrial use is most desired. The aim and purpose of the article was to show the importance of renewable energy sources i.e. geothermal energy in industrial use in Poland. The work was based on the use of compact book literature, statistical data, as well as on the basis of Internet sources of information and publications. The publication presents the nature of the geothermal power industry, its role and significance for economies in the world and in Poland. Countries that make the most use of geothermal installations are mentioned. Conditions and barriers resulting from the use of geothermal energy are presented. A special place in this publication is given to the industrial use of geothermal power in Poland. As an example, the first geothermal plant was established in our country in Banska Nizna. The presented data is illustrated with tables and graphs. The research method used in the article was the analysis of existing data and literature review. The assumption that geothermal energy can be an important source of energy for industrial use is the thesis. However, it must take into account both its advantages and shortcomings. The study positively verified the thesis.
Energetyka geotermalna może stanowić interesujące pod wieloma względami źródło energii odnawialnej. Wśród jej wielu rozmaitych zastosowań na uwagę zasługuje wykorzystanie przemysłowe. Celem i przedmiotem artykułu było ukazanie znaczenia odnawialnego źródła energii, jakim jest energia geotermalna, w wykorzystaniu przemysłowym na terenie Polski. Praca powstała na podstawie dostępnej zwartej literatury książkowej, danych statystycznych oraz publikacji i wiadomości netograficznych.W artykule ukazano zasady funkcjonowania energetyki geotermalnej, jej rolę i znaczenie dla gospodarek na świecie i w Polsce. Wymieniono te kraje, które w największym stopniu wykorzystują praktycznie instalacje geotermiczne. Dokonano zestawienia przesłanek i barier wynikających z wykorzystywania geotermiki. Szczególną rolę w niniejszej publikacji poświęcono przemysłowemu wykorzystywaniu energetyki geotermalnej w Polsce. Jako przykład wybrano pierwszy zakład geotermalny na terenie naszego kraju – w miejscowości Bańska Niżna.Zaprezentowane dane zostały zilustrowane przy pomocy tabel i wykresów. Metodą badawczą wykorzystaną w artykule była analiza danych zastanych oraz krytyka piśmiennicza. Tezą, jaką postawiono w publikacji, jest założenie, że energetyka geotermalna może stanowić ważne źródło energii w wykorzystaniu przemysłowym. Należy jednak brać pod uwagę zarówno jej zalety, jak i mankamenty. Wyniki analizy danych zastanych pozytywnie zweryfikowały postawioną tezę.
Źródło:
Prace Komisji Geografii Przemysłu Polskiego Towarzystwa Geograficznego; 2018, 32, 2; 73-82
2080-1653
Pojawia się w:
Prace Komisji Geografii Przemysłu Polskiego Towarzystwa Geograficznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instalacja geotermalna w Pyrzycach jako przykład pozyskiwania czystej i odnawialnej energii w ciepłownictwie oraz wód termalnych do balneologii i rekreacji
Geothermal heating plant in Pyrzyce (NW Poland) as an example of sourcing of thermal energy and waters for balneology and recreation
Autorzy:
Biernat, H.
Kulik, S.
Noga, B.
Powiązania:
https://bibliotekanauki.pl/articles/2074805.pdf
Data publikacji:
2010
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
energia geotermalna
region Pyrzyc
Polska
geothermal energy
Gorzów Block
NW Poland
Opis:
Thermal waters (61°C) occurring in the Lower Jurassic reservoirs in the Pyrzyce region (approx. 1600 m b.s.l.) are used mainly in heating plant and their chemical composition allow to apply them in balneology and recreation. In the summer time in the Pyrzyce plant only the geothermal waters are used. In the autumn-winter season, when higher temperatures of water for municipal network are needed, the system is supported by absorption heat pumps. Usage of geothermal waters in the Pyrzyce municipal heat system eliminated small carbon boilers and reduced considerable emission of harmful substance to atmosphere.
Źródło:
Przegląd Geologiczny; 2010, 58, 8; 712-716
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies