Wyszukujesz frazę "heat tube exchanger" wg kryterium: Wszystkie pola


Wyświetlanie 1-28 z 28
Tytuł:
Calculation of the heat power of a tube heat exchanger
Autorzy:
Rup, Kazimierz
Powiązania:
https://bibliotekanauki.pl/articles/2091366.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat power
tube-in-tube exchanger
analytical solutions
numerical calculations
Opis:
In this paper, the logarithmic mean temperature difference method is used to determine the heat power of a tube-in-tube exchanger. Analytical solutions of the heat balance equations for the exchanger are presented. The considerations are illustrated by an example solution of the problem. In particular, the heat power of the tube-in-tube heat exchanger is determined taking into account the variants of work in the co-current and counter-current mode. Apart from the analytical solutions, appropriate numerical calculations in Matlab environment have been carried out.
Źródło:
Archives of Thermodynamics; 2022, 43, 1; 127--140
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical modelling of tube heat exchangers with complex flow arrangement
Autorzy:
Taler, D.
Trojan, M.
Taler, J.
Powiązania:
https://bibliotekanauki.pl/articles/185235.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wymiennik ciepła
przepływ
modelowanie
heat tube exchanger
modelling
complex flow
Opis:
General principles of mathematical modelling of transient heat transfer in cross-flow tube heat exchangers with complex flow arrangements which allow a simulation of multipass heat exchangers with many tube rows are presented. First, a system of differential equations for the transient temperature of both fluids and the tube wall with appropriate boundary and initial conditions is formulated. Two methods for modelling heat exchangers are developed using the finite difference method and finite volume method. A numerical model of multipass steam superheater with twelve passes is presented. The calculation results are compared with the experimental data.
Źródło:
Chemical and Process Engineering; 2011, 32, 1; 7-19
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fluid flow consideration in fin-tube heat exchanger optimization
Autorzy:
Wais, P.
Powiązania:
https://bibliotekanauki.pl/articles/240200.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CFD
przepływ płynu
wymiennik optymalizacji
Exchanger optimization
Fin profile
fluid flow
Opis:
The optimization of finned tube heat exchanger is presented focusing on different fluid velocities and the consideration of aerodynamic configuration of the fin. It is reasonable to expect an influence of fin profile on the fluid streamline direction. In the cross-flow heat exchanger, the air streams are not heated and cooled evenly. The fin and tube geometry affects the flow direction and influences temperature changes. The heat transfer conditions are modified by changing the distribution of fluid mass flow. The fin profile impact also depends on the air velocity value. Three-dimensional models are developed to find heat transfer characteristics between a finned tube and the air for different air velocities and fin shapes. Mass flow weighted average temperatures of air volume flow rate are calculated in the outlet section and compared for different fin/tube shapes in order to optimize heat transfer between the fin material and air during the air flow in the cross flow heat exchanger.
Źródło:
Archives of Thermodynamics; 2010, 31, 3; 87-104
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PIV measurement of tube-side in a shell and tube heat exchanger
Autorzy:
Wang, K.
Zhang, Z.
Liu, Q.
Tu, X.
Hyoung-Bum, K.
Powiązania:
https://bibliotekanauki.pl/articles/778192.pdf
Data publikacji:
2018
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
shell and tube heat exchanger
tube-side
PIV
unsteady flow
Opis:
In order to improve the performance of the shell and tube heat exchanger, a porous baffle and a splitter bar are employed in this research. Through the arrangement of the porous baffle in the tube-side inlet and the splitter bar in the tube, the flow distribution of liquid in the heat exchanger is improved. PIV technology is used to investigate the unsteady flow in the tube-side inlet and the outlet of different models. The porous baffle significantly improves the flow of fluid in the shell and tube heat exchanger, especially by eliminating/minimizing the maldistribution of fluid flow in the tube-side inlet. The performance of the arc baffle is better than that of the straight baffle. The splitter bar has a minimal effect on the flow field of the tube-side inlet, but it effectively improves the flow in the tube bundle and restrains the vortex generation in the tube-side outlet.
Źródło:
Polish Journal of Chemical Technology; 2018, 20, 1; 60-66
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis of the steam flow field in shell and tube heat exchanger
Autorzy:
Bartoszewicz, J.
Bogusławski, L.
Powiązania:
https://bibliotekanauki.pl/articles/240429.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat transfer
heat exchanger
shell and tube heat exchanger
przenikanie ciepła
wymiennik ciepła
wymiennik płaszczowo-rurowy
Opis:
In the paper, the results of numerical simulations of the steam flow in a shell and tube heat exchanger are presented. The efficiency of different models of turbulence was tested. In numerical calculations the following turbulence models were used: k-ε, RNG k-ε, Wilcox k-ω, Chen-Kim k-ε, and Lam-Bremhorst k-ε. Numerical analysis of the steam flow was carried out assuming that the flow at the inlet section of the heat exchanger were divided into three parts. The angle of steam flow at inlet section was determined individually in order to obtain the best configuration of entry vanes and hence improve the heat exchanger construction. Results of numerical studies were verified experimentally for a real heat exchanger. The modification of the inlet flow direction according to theoretical considerations causes the increase of thermal power of a heat exchanger of about 14%.
Źródło:
Archives of Thermodynamics; 2016, 37, 2; 107-120
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fretting wear analysis of different tube materials used in heat exchanger tube bundle
Autorzy:
Abbas, T.
Khushnood, S.
Nizam, L. A.
Usman, M.
Powiązania:
https://bibliotekanauki.pl/articles/957958.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
fretting wear
flow-induced vibration
flexible tube
cross flow velocity
Opis:
Research on heat exchange has been carried out for more than five decades because of its importance in process industries and power generation plants. Heat exchanger experiencing cross flow are vulnerable to flow-induced vibration. This vibration causes the interaction of tubes with the baffle resulting in a fretting wear of the tubes. The present study focuses on fretting wear analysis of different tube materials. Fretting wear tests were performed on aluminum, copper and stainless steel instrumented central tubes against mild steel baffle. For each tube material the tests were performed for three different test durations i.e. 60 minutes, 120 minutes and 180 minutes at a cross flow velocity of 0.55 m/s. It was observed that vibrational amplitude of the flexible test tube is affected by its weight. A scanning electron microscope was used to analyze and measure the sizes of wear scar. The results indicated that wear loss in case of aluminum tube is the highest while that in case of stainless steel tube is the lowest.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 123-133
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of non-equidistant baffle spacing in a small shell and tube heat exchanger
Autorzy:
Aziz, Abdullah
Rehman, Shafique
Powiązania:
https://bibliotekanauki.pl/articles/240423.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal distribution
baffle spacing
heat exchanger
turbulence modeling
CFD study
Opis:
Most of the formulations regarding the characteristics of a shell and tube heat exchanger have a common assumption; namely that the baffle plates are equidistant. This assumption fails to cater the real world scenario for defective baffles as the alteration in a shell and tube heat exchanger invalidates the equidistant baffle spacing of the plates. In this regard, a small six baffles heat exchanger was modeled in the computational fluid dynamics software package and studied by removing each baffle plate one at a time. Effect of removing each baffle plate on the temperature, pressure, heat transfer coefficient, and total heat transfer rate was recorded. It was observed that variation in the pressure drop for the same number of baffle plates varies along the axial order of the plates. The change in pressure drop due to the removal of the baffle plate near the inlet and the outlet was lowest and reaches a maximum in the axial center. It was also found that the plates below the radial center contribute higher towards the overall heat transfer as compared to those above.
Źródło:
Archives of Thermodynamics; 2020, 41, 2; 201-221
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of serrated circular rings on heat transfer augmentation of circular tube heat exchanger
Autorzy:
Kharkwal, Himanshi
Singh, Satyendra
Powiązania:
https://bibliotekanauki.pl/articles/2091375.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat transfer rate
friction factor
thermal performance factor
serrated circular ring
Opis:
Limiting energy resources has led researchers to find new innovative ways to enhance heat exchanging devices thermal performance in power generating systems. Thus, the present paper analyzes passive techniques of enhancing the thermal performance of a single tube heat exchanger. Experimental and numerical investigation on heat transfer enhancement using aserrated circular ring with twisted tape is carried out. The work incorporates the determination of Nusselt number, friction factor, thermal performance factor for serrated circular ring with twisted tape with variation in diameter ratio (0.8 and 0.85) and pitch ratio (2 and 3). Air is used as a working fluid with Reynolds number 6000–24000. The experiment is conducted by providing a constant wall heat flux of 1000 W/m2 to the system and thereby taking results at a steady state. The experimental and computational findings obtained for the smooth tube case are compared with the standard correlations of Dittus–Boelter and Blasius. Based on experimental and numerical investigation, there is 5.16 times augmentation in heat transfer and 3.05 times improvement in thermal performance factor over the smooth tube heat exchanger. In addition, the study of entropy generation rate for every geometrical parameter has been conducted, and their influence on the system’s thermal behaviour is presented. The results obtained in the present study may help the researchers of the same research area to find similar inserts and new ways of enhancing the thermal performance of heat exchangers.
Źródło:
Archives of Thermodynamics; 2022, 43, 2; 129--155
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An advanced thermal-FSI approach of an evaporation of air heat pump
Autorzy:
Felicjancik, J.
Ziółkowski, P.
Badur, J.
Powiązania:
https://bibliotekanauki.pl/articles/175437.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CFD modeling
evaporator
fin-tube heat exchanger
heat transfer
Opis:
The paper presents selected problems of numerical modelling of an advanced thermal- FSI (Fluid solid interaction) approach of evaporator of air heat pump. The example of a fin-tube evaporator has been studied, focusing on obtaining the heat exchanger characteristics applying two-phase flow model for the in-tube refrigerant flow. Special attention is given to heat transfer between separated medium for different air velocity and changed refrigerant mass flow in-tube.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2015, 129; 111-141
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal and economic investigation of straight and U-bend double tube heat exchanger with coiled wire turbulator
Autorzy:
Andrzejczyk, Rafał
Muszyński, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/239983.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
NTU – number of transfer units
heat exchanger
heat transfer coefficient
energy efficiency
wymiennik ciepła
współczynnik wnikania ciepła
efektywność energetyczna
metoda NTU
Opis:
Experimental research has been carried out for four individual heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend and U-bend with turbulator. Tests were made for the water-water system. The study covered a wide measuring range, i.e., Re = 800–9000 – on the shell side, for a constant cold water temperature of 9°C and hot water of 50°C. The heat exchangers were made from copper tubes with external diameter of 10 mm and 18 mm respectively and wall thickness of 1 mm. The helicoidal vortex generator was made from brass wire with a diameter of 2.4 mm, coil diameter of 13 mm and pitch of 11 mm. For these geometries, the values of pressure drop, heat flux and heat transfer coefficient were determined. Wire coil turbulator increased the heat transfer coefficient (HTC) over 100% and pressure drop up by 100%. The comparison of heat transfer efficiency was performed based on the number of transfer units-effectivenes (NTU-ε) method. The modified construction achieved a similar efficiency. Economic analysis of wire coil turbulator was made to validate its use in the system. It showed that a coiled wire turbulator can greatly decrease the investment cost of the double tube heat exchanger while maintaining transferred heat at a constant level.
Źródło:
Archives of Thermodynamics; 2019, 40, 2; 17-33
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the Effects of the Incident Flow Angle on Vibration Behavior in Heat Exchanger Tube Bundle
Autorzy:
Usman, Muhammad
Khushnood, Shahab
Nizam, Luqman Ahmad
Tanveer, Waqas
Shafi, Ahmad
Ayub, Muhammad
Khan, Hassan Farid
Rustam, Behzad
Powiązania:
https://bibliotekanauki.pl/articles/102083.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
incident flow angle
fluid elastic instability
flow-induced vibration
parallel triangular array
cross flow velocity
flexible tube
kąt przepływu
niestabilność sprężysta płynu
drgania indukowane przepływem
równoległy układ trójkątny
prędkość przepływu poprzecznego
elastyczna rura
Opis:
An experimental study on the incident flow angle effects on the vibration behavior was carried out on aluminum tube in parallel triangular tube bundle with P/D ratio of 1.375. Fluid elastic instability is the most fatal mechanism from all the vibration mechanisms and therefore must be dealt with a lot of attention. Experiments were performed on low speed water tunnel with the velocity of water ranges from 0.3 m/s to 0.7 m/s. The experiments were designed in a unique way to study the effects of incident flow angle on the vibration behavior. The monitored tube was mounted flexibly in an array of rigid tubes. The experiments were conducted on a flexible tube for different velocities ranging from 0.3 m/s to 0.7 m/s with different array rotated angles (0 to 90 degrees). It was observed that the vibration level was significantly high at 75 degree configuration as compared to other rotated angle configurations. It was also observed that the damping response is dispersed with all positive values, indicating that there is no instability in the tube.
Źródło:
Advances in Science and Technology. Research Journal; 2019, 13, 2; 186-194
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental investigation of heat transfer performance coefficient in tube bundle of shell and tube heat exchanger in two-phase flow
Autorzy:
Karaś, M
Zając, D.
Ulbrich, R.
Powiązania:
https://bibliotekanauki.pl/articles/239957.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
two-phase flow
heat transfer coefficient
tube bundle
heat exchanger
DPIV
przepływ dwufazowy
współczynnik wnikania ciepła
pęk rur
wymiennik ciepła
Opis:
This paper presents the results of studies in two phase gasliquid flow around tube bundle in the model of shell tube heat exchanger. Experimental investigations of heat transfer coefficient on the tubes surface were performed with the aid of electrochemical technique. Chilton-Colburn analogy between heat and mass transfer was used. Twelve nickel cathodes were mounted on the outside surface of one of the tubes. Measurement of limiting currents in the cathodic reduction of ferricyanide ions on nickel electrodes in aqueous solution of equimolar quantities of K3Fe(CN)6 and K4Fe(CN)6 in the presence of NaOH basic solution were applied to determine the mass transfer coefficient. Controlled diffusion from ions at the electrode was observed and limiting current plateau was measured. Measurements were performed with data acquisition equipment controlled by software created for this experiment. Mass transfer coefficient was calculated on the basis of the limiting current measurements. Results of mass transfer experiments (mass transfer coefficient) were recalculated to heat transfer coefficient. During the experiments, simultaneously conducted was the the investigation of two-phase flow structures around tubes with the use of digital particle image velocimetry. Average velocity fields around tubes were created with the use of a number of flow images and compared with the results of heat transfer coefficient calculations.
Źródło:
Archives of Thermodynamics; 2014, 35, 1; 87-98
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heating system with vapour compressor heat pump and vertical U-tube ground heat exchanger
Autorzy:
Hanuszkiewicz-Drapała, M.
Składzień, J.
Powiązania:
https://bibliotekanauki.pl/articles/240620.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gruntowy wymiennik ciepła
modelowanie numeryczne
pompa ciepła
system grzewczy
ground heat exchanger
heat pump
heating system
numerical modelling
Opis:
In the paper a heating system with a vapour compressor heat pump and vertical U-tube ground heat exchanger for small residential house is considered. A mathematical model of the system: heated object - vapour compressor heat pump - ground heat exchanger is presented shortly. The system investigated is equipped, apart from the heat pump, with the additional conventional source of heat. The processes taking place in the analyzed system are of unsteady character. The model consists of three elements; the first containing the calculation model of the space to be heated, the second the vertical U-tube ground heat exchanger with the adjoining area of the ground. The equations for the elements of vapour compressor heat pump form the third element of the general model. The period of one heating season is taken into consideration. The results of calculations for two variants of the ground heat exchanger are presented and compared. These results concern variable in time parameters at particular points of the system and energy consumption during the heating season. This paper presents the mutual influence of the ground heat exchanger subsystem, elements of vapour compressor heat pump and heated space.
Źródło:
Archives of Thermodynamics; 2010, 31, 4; 93-110
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nierównomierności przepływu cieczy wzdłuż pęku rur wymiennika ciepła z przegrodami segmentowymi
Research of fluid flow non-uniformity along the tube bundle in a heat exchanger with segmental baffles
Autorzy:
Ligus, G.
Powiązania:
https://bibliotekanauki.pl/articles/2073075.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
płaszczowo-rurowy wymiennik ciepła
przegrody segmentowe
DPIV
shell and tube heat exchanger
segmental baffles
Opis:
Przedstawiono wyniki badań eksperymentalnych hydrodynamiki przepływu cieczy w przestrzeni międzyrurowej modelowego płaszczowo-rurowego wymiennika ciepła z przegrodami segmentowymi. W badaniach wykorzystano nieinwazyjną metodę optyczną - cyfrową anemometrię obrazową (DPIV). Zaprezentowano zarys metody identyfikacji wirów stagnacyjnych wywołanych geometrią aparatu. Opisano również możliwość rozpoznawania obszarów o wzmożonej intensywności występowania przepływów szczelinowych.
The results of hydrodynamics experimental research during fluid flow in the shell side of shell-and-tube heat exchanger with segmental baffles model were presented in the paper. Research using non-invasive optical method - Digital Particle Image Velocity was implemented. The own author draft of the method of identification of stagnant vortex generated by the geometry of apparatus was presented. Also the possibility of recognition of increased intensity areas with clearance flow was described.
Źródło:
Inżynieria i Aparatura Chemiczna; 2016, 2; 60--61
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistical analysis of entropy generation in longitudinally finned tube heat exchanger with shell side nanofluid by a single phase approach
Autorzy:
Konchada, P. K.
Pv, V.
Bhemuni, V.
Powiązania:
https://bibliotekanauki.pl/articles/240513.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
longitudinal finned tube heat exchanger
user functions and CEL Expressions
ANSYS CFX
Taguchi
entropy generation
wymiennik ciepła
rury żebrowane
funkcje użytkownika
generowanie entropii
Opis:
The presence of nanoparticles in heat exchangers ascertained increment in heat transfer. The present work focuses on heat transfer in a longitudinal finned tube heat exchanger. Experimentation is done on longitudinal finned tube heat exchanger with pure water as working fluid and the outcome is compared numerically using computational fluid dynamics (CFD) package based on finite volume method for different flow rates. Further 0.8% volume fraction of aluminum oxide (Al2O3) nanofluid is considered on shell side. The simulated nanofluid analysis has been carried out using single phase approach in CFD by updating the user-defined functions and expressions with thermophysical properties of the selected nanofluid. These results are thereafter compared against the results obtained for pure water as shell side fluid. Entropy generated due to heat transfer and fluid flow is calculated for the nanofluid. Analysis of entropy generation is carried out using the Taguchi technique. Analysis of variance (ANOVA) results show that the inlet temperature on shell side has more pronounced effect on entropy generation.
Źródło:
Archives of Thermodynamics; 2016, 37, 2; 3-22
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of the flow pattern of liquid streams in the shell-side of a segmental-baffled shell-and-tube heat exchanger
Autorzy:
Ligus, G.
Zając, D.
Kołodziej, S.
Powiązania:
https://bibliotekanauki.pl/articles/95380.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
PIV
particle image velocimetry
shell and tube heat exchanger
tube bundles
leakage stream
bypass stream
anemometria obrazowa
wymiennik płaszczowo-rurowy
wiązki rur
strumień wycieku
strumień obejściowy
Opis:
Shell-and-tube heat exchangers are widely used in chemical and process engineering. Assessing hydrodynamics of fluid flow in their shell-side is a highly complex task. This results from the complex geometry of the shell-side itself, defined by such parameters as the tubesheet layout, tube diameter, baffle spacing or baffle cut. Shell-and-tube heat exchangers are the subject of many studies in which design and flow parameters are analysed. However, only a few studies concentrate on issues strictly related to the identification of streams of the liquid flowing in the shell-side of apparatus on an industrial scale. In this article, the authors present the results of an experimental visualization study, utilizing Particle Image Velocimetry (PIV). The experiment used a laser sheet technique along and across a tube bundle. The main results of the measurements and analyses concentrate on identifying the flow pattern of streams in the shell-side and assessing stagnation vortices and their consequences. Finally, detecting bypass streams and leakage streams flowing through design gaps between the shell and the tube bundle as well as between the baffles and the tubes in the bundle are presented.
Źródło:
Journal of Mechanical and Energy Engineering; 2018, 2, 3; 245-256
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model matematyczny oraz badania aerodynamiczne i przepływowo-cieplne chłodnicy samochodowej
Mathematical model and experimental study of a plate-fin-and-tube heat exchanger
Autorzy:
Taler, D.
Powiązania:
https://bibliotekanauki.pl/articles/263742.pdf
Data publikacji:
2001
Wydawca:
Sieć Badawcza Łukasiewicz. Przemysłowy Instytut Motoryzacji
Tematy:
badanie aerodynamiczne
chłodnica samochodowa
liczba Nusselta
model matematyczny
experimental study
heat exchanger
mathematical model
Nusselt number
Opis:
Przedstawiono analityczny model wymiany ciepła w chłodnicy samochodowej stanowiącej krzyżowo-prądowej lamelowy wymiennik ciepła. Wyprowadzono wzory na rozkład temperatury cieczy wewnątrz rury oraz temperatury powietrza w dwubiegowej chłodnicy o dwóch rzędach rur. Za pomocą wyprowadzonych wzorów można określić strumienie ciepła przekazywane przez poszczególne rzędy rur, a także moc chłodnicy przy zadanych temperaturach wlotowych i strumieniowych masowych czynników. W pracy omówiono wyniki badań aerodynamicznych, hydraulicznych i cieplnych chłodnicy silnika o pojemności skokowej 1580 m[^3]. Na podstawie przeprowadzonych badań wyznaczono wzory na współczynniki charakteryzujące opory przepływu powietrza i płynu chłodzącego oraz wzór na liczbę Nusselta od strony powietrza.
An analytical mathematical model of two-row plate-fin exchangers is presented. The temperature distributions on the fluid and air sides can easily be calculated using the developed model. The comparison of calculated results with experimental data for the automotive radiator shows that the mathematical model is very accurate. The results of the experimental investigation of the plate-fin-and-tube automotive radiator are presented. The tested two-pass radiator consists of two inline rows of tubes with smooth plate fins. The objective was to derive the correlations for the friction factors and the air-side heat transfer coefficient as a function of the Reynolds numbers. The air side heattransfer coefficient was determined from the condition that the calculated and measured coolant outlet temperatures aer equal.
Źródło:
Archiwum Motoryzacji; 2001, 4; 145-162
1234-754X
2084-476X
Pojawia się w:
Archiwum Motoryzacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary temperatury w gruncie oraz w gruntowym wymienniku ciepła (GWC) w rocznym cyklu eksploatacyjnym
Ground and ground tube heat exchanger temperature measurements within the operating cycle of one year
Autorzy:
Sikora, K.
Powiązania:
https://bibliotekanauki.pl/articles/157398.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
gruntowy wymiennik ciepła
pomiar pól temperatury w gruncie
ground tube heat exchanger
temperature distribution in the ground
Opis:
W artykule przedstawiono układ do pomiaru i rejestracji temperatury w wybranych punktach w obszarze gruntu, oraz w obszarze powietrznym gruntowego wymiennika ciepła (GWC), oraz przedstawiono i omówiono wyniki pomiarów dla rocznego cyklu eksploatacyjnego GWC. Celem pomiarów było wyznaczenie efektywności wymiennika oraz pozyskanie danych do weryfikacji numerycznego modelu wymiennika gruntowego. Na podstawie pomiarów określono kryteria efektywnej pracy wymiennika.
Experimental investigations of the ground tube heat exchanger were performed. An automatic measurement system for data acquisition was constructed. The system consists of six RTD temperature sensors, one thermoanemometric sensor, a multichannel power supply and a PC with the Advantech USB 4711 acquisition module (see Fig. 1). All the sensors were calibrated and the profile of the velocity distribution along the tube was determined for the thermoanemometric sensor. The measurement data were written to .xls files (three days in one file). For this purpose the own data acquisition program in VBA was developed. The measurement period began in January 2006 and ended in April 2007. The experimental data were averaged to one hour and extended with those taken at the IMGW meteorological station in Bielsko-Biala Aleksandrowice (relative humidity and absolute pressure of the ambient air). On the basis of these data, the heat fluxes were calculated (heat transfer from the ground to the air). The ground tube heat exchanger efficiency was also calculated. The thermal ground diffusivity value necessary for numerical analysis was determined from the experimental data in the form of the ground temperature distributions (Fig. 2).
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 3, 3; 265-267
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilization of Process Wastewater Heat
Utylizacja ciepła ścieków poprodukcyjnych
Autorzy:
Szkarowski, Aleksander
Jaworski, Łukasz
Mamedov, Shirali
Powiązania:
https://bibliotekanauki.pl/articles/1811632.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
process wastewaters
heat recovery
shell and tube heat exchanger
cross-flow heat exchanger
ścieki produkcyjne
odzysk ciepła
wymiennik płaszczowo-rurowy
wymiennik krzyżowy
Opis:
This papers presents the results of computation of two heat exchangers used for heat utilization of industrial wastewater generated in a refined fiberboard production plant. The basic task was to cool wastewater to a temperature of approximately 40ºC enabling efficient centrifugation of suspended matter at the stage of wastewater pretreatment. A shell-and-tube heat exchanger with the power of 473 kW for water heating was developed for heating the production hall. A cross-flow exchanger was also developed for heating ventilation air in the boiler room building, power of which is 1703 kW. Thermal and hydraulic computation was performed, the required heat exchange surface was selected, the main structural characteristics of both exchangers were determined.
W niniejszym artykule przedstawiono wyniki obliczeń dwóch wymienników ciepła typu służących do utylizacji ciepła ścieków przemysłowych powstających w zakładzie do produkcji uszlachetnionych płyt pilśniowych. Zadaniem podstawowym było schładzanie ścieków do temperatury ok. 40ºC umożliwiającej sprawne odwirowanie zawieszonych substancji na etapie wstępnego podczyszczania ścieków. Opracowano wymiennik płaszczowo-rurowy podgrzewający wodę na cele ogrzewania hali produkcyjnej o mocy 473 kW. Opracowano również wymiennik krzyżowy na cele podgrzania powietrza wentylacyjnego w budynku kotłowni, którego moc wynosi 1703 kW. Wykonano obliczenia cieplne i hydrauliczne, dobrano wymaganą powierzchnię wymiany ciepła, określono główne charakterystyki konstrukcyjne obu wymienników.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 2; 1074-1083
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model symulacyjny oraz obliczenia wysokotemperaturowego wymiennika ciepła dedykowanego do pracy w układzie mikrokogeneracyjnym
Simulation model and calculation of high temperature shell and tube heat exchanger dedicated to work in microcogeneration
Autorzy:
Król, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/101729.pdf
Data publikacji:
2018
Wydawca:
Politechnika Śląska. Wydział Inżynierii Środowiska i Energetyki. Instytut Techniki Cieplnej
Tematy:
wymiennik ciepła
mikrokogeneracja
obliczenia cieplne
heat exchanger
microcogeneration
thermal calculations
Opis:
Kogeneracja jest to proces zamiany energii chemicznej paliwa na energię mechaniczną, elektryczną, ciepło bądź chłód realizowaną w jednej maszynie lub w zespołach maszyn wzajemnie połączonych ze sobą. Proces ten może być realizowany w dużej skali w konwencjonalnych układach skojarzonych lub w małej lokalnej skali zwanej mikrokogeneracją. Jedną z technologii mikrokogeneracyjnych są układy oparte na silnikach spalinowych. W silnikach istnieje wiele źródeł ciepła, lecz głównie jest to ciepło niskotemperaturowe.W ramach pracy opracowano model obliczeniowy symulujący pracę wymiennika ciepła. Opisano metody obliczeniowe stosowane do szacowania współczynników przenikania ciepła oraz strat ciśnienia. Uzyskano wyniki obliczeń dla stanu nominalnego. Przeprowadzono studium przypadku dla: zmiennych wariantów geometrycznych (zmiana szyku, zmiana średnicy rur, zmiana średnicy płaszcza, zmiana ilości przegród poprzecznych), zmienionego rodzaju paliwa oraz przy zmieniającym się punkcie pracy silnika spalinowego. Uzyskano parametry geometryczne wymiennika do pracy w układach mikrokogeneracyjncyh o niskiej mocy–średnica płaszcza wyniosła 220mm, długość wymiennika 853 mm, liczba rur 87. Wymiennik będzie pracował w zakresie mocy 5-6,5 kW co odpowiada zakresowi regulacji silnika spalinowego. Dodatkowo przeanalizowano możliwości regulacji instalacji pod kątem przepływającego glikolu, dla zachowania stałego przyrostu temperatury w wymienniku. Instalację należy regulować w przedziale 12-18kg/min.
Cogeneration is the conversion process of fuel chemical energy into mechanical, electric, heat or cool produced in one machine or in group with connection between them. This process can be conducted in the large scale in classic CHP units or in the small local scale which is known as microcogeneration. One of microcogeneration technologies are systems based on internal combustion engines. There are various sources of utility heat, but significant amount of them are low temperature heat. In this thesis mathematical model dedicated to simulation heat ex-changer work was created. Calculations used to estimate convective heat transfer coefficient and pressure loses were described and results in nominal state were obtained. Furthermore afew case studies which took under consideration:variable geometrical parameters (pattern change, change of pipe diameter, change of shell diameter, various baffle number), various fuel type andwere conductedin engine different working conditions.Typical parameters for shell and tube dedicated for low power microcogeneration has been obtained–for shell diameter 220 mm, for heat exchanger length 853, and amounts of pipes 87. Heat Exchanger will be working in power range 5-6,5 kW, what is connected with engine regulation range. Additionally regu-lation perspective has been analyzed, when constant temperature growth is needed installation should be regulated in range 12-18 kg/min.
Źródło:
Archiwum Instytutu Techniki Cieplnej; 2018, 5; 63-89
2451-277X
Pojawia się w:
Archiwum Instytutu Techniki Cieplnej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Initial investigations of coil heat exchanger utilizing waste heat from air conditioning system
Badania wstępne wężownicowego wymiennika ciepła wykorzystującego ciepło odpadowe z systemu klimatyzacji
Autorzy:
Wilk, J.
Smusz, R.
Powiązania:
https://bibliotekanauki.pl/articles/195199.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
tube coil heat exchanger
thermal-flow characteristics
temperature stratification
wężownicowy wymiennik ciepła
charakterystyki cieplno-przepływowe
stratyfikacja temperatury
Opis:
In this paper the selected results of testing of tube coil heat exchanger have been presented. The investigated heat exchanger is designed to preheating domestic warm water with the use of waste heat from air conditioning system. The tested device consists of finned tube coil heat exchanger immersed in the thermal storage tank. The tank is equipped with three heating coils and the cylindrical-shaped temperature stratification system. Two coils use water as a heating medium. The third, double-wall heat exchanger coil is filled with the refrigerant from the air conditioning system. The industrial stand enables the experimental investigations of thermal and flow characteristics of the exchanger. In the paper the authors present the technological scheme of the test stand, specification of components of the stand, research possibilities and the exemplary results of characteristic temperature and pressure measurements.
W pracy przedstawiono wybrane wyniki badań wężownicowego wymiennika ciepła. Testowane urządzenie jest przeznaczone do podgrzania ciepłej wody użytkowej przy użyciu ciepła odpadowego pochodzącego z systemu klimatyzacji. Badane urządzenie stanowi wymiennik ciepła złożony z użebrowanych wężownic zanurzonych w zbiorniku termicznym. Zbiornik jest wyposażony w trzy wężownice grzejne oraz cylindryczny układ stratyfikacji temperatury. Czynnikiem roboczym w dwóch wężownicach jest woda. Trzeci dwuścienny wężownicowy wymiennik ciepła jest zasilany czynnikiem chłodniczym z układu klimatyzacji. Stanowisko przemysłowe umożliwia przeprowadzenie badań eksperymentalnych charakterystyk cieplno-przepływowych wymiennika. W pracy autorzy przedstawili schemat technologiczny stanowiska badawczego wraz z wykazem i charakterystyką jego poszczególnych elementów. Podano również możliwości badawcze oraz przytoczono przykładowe wyniki pomiarów temperatur i ciśnień charakterystycznych.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika; 2017, z. 89 [295], 1; 131-138
0209-2689
2300-5211
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu rozwiązań konstrukcyjnych wymienników ciepła na wybrane parametry produktu spożywczego
Research into the influence of structural design of heat exchangers on selected parameters of food product
Autorzy:
Perz, K.
Rewolińska, A.
Kotarba, T.
Powiązania:
https://bibliotekanauki.pl/articles/2073005.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wymiennik ciepła
rura w rurze
rura w rurze w rurze
podgrzewanie produktu
heat exchanger
tube in tube
tube in tube in tube
product heating
Opis:
Przeprowadzono badania wpływu typu wymiennika ciepła ("rura w rurze" oraz "rura w rurze w rurze") na kluczowe parametry ogrzewanej zupy modelowej. Mierzono lepkość, barwę, zawartość soli, konsystencję oraz kwasowość. Stwierdzono, że badane parametry produktów podgrzewanych w obu wymiennikach nie różniły się znacząco. Z energetycznego punktu widzenia wymiennik ciepła typu „rura w rurze w rurze” był bardziej efektywny, a w wymienniku typu „rura w rurze” istniało mniejsze prawdopodobieństwo przypalenia produktu.
Research into the influence of different types of heat exchangers (“tube in tube” and “tube in tube in tube”) on the key parameters of model heated soup are presented. Such parameters as viscosity, color, salt content, consistency and acidity were tested during the research. The study showed that there were no significant differences between parameters of products heated in both heat exchangers. From the energy consumption point of view the “tube in tube in tube” heat exchanger was more effective. However, in the “tube in tube” heat exchanger the product overburning is less probable.
Źródło:
Inżynieria i Aparatura Chemiczna; 2016, 3; 104--105
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inverse heat transfer problem in digital temperature control in plate fin and tube heat exchangers
Autorzy:
Taler, D.
Sury, A.
Powiązania:
https://bibliotekanauki.pl/articles/240927.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odwrotny przepływ ciepła
regulacja temperatury
wymiennik ciepła
digital PID control
heat exchanger
inverse heat transfer problem
model-based control
temperature control
Opis:
The aim of the paper is a steady-state inverse heat transfer problem for plate-fin and tube heat exchangers. The objective of the process control is to adjust the number of fan revolutions per minute so that the water temperature at the heat exchanger outlet is equal to a preset value. Two control techniques were developed. The first is based on the presented mathematical model of the heat exchanger while the second is a digital proportional-integral-derivative (PID) control. The first procedure is very stable. The digital PID controller becomes unstable if the water volumetric flow rate changes significantly. The developed techniques were implemented in digital control system of the water exit temperature in a plate fin and tube heat exchanger. The measured exit temperature of the water was very close to the set value of the temperature if the first method was used. The experiments showed that the PID controller works also well but becomes frequently unstable.
Źródło:
Archives of Thermodynamics; 2011, 32, 4; 17-32
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania przenoszenia pędu i ciepła przy opływie rur w wymienniku ciepła
Research of heat and momentum transfer during flow over a tube bundle in the heat exchanger
Autorzy:
Karaś, M.
Ulbrich, R.
Zając, D.
Powiązania:
https://bibliotekanauki.pl/articles/2071901.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przepływ dwufazowy
wnikanie ciepła
metody elektrochemiczne
DPIV
two-phase flow
heat transfer
electrochemical method
Opis:
W pracy przedstawiono wyniki badań przepływu dwufazowego wokół pęku rur. Analizie poddano przestawne i równoległe układy rur w pęku o podział- ce równej 1,66. Wyznaczono pola prędkości oraz rozkład współczynnika wnikania ciepła wokół rur przy pomocy technik DPIV i elektrochemicznej. Wyniki zaprezentowano dla różnych strumieni poszczególnych faz w postaci pól prędkości oraz lokalnych rozkładów liczby Nusselta wokół poszczególnych rur w pęku.
This paper presents results of recent studies in two-phase flow around a tube bundle in the model of shell-and-tube heat exchanger. Two types of models of the in-line and staggered arrays with pitch to diameter ratio equal to 1.66 were examined. Two measuring techniques (DPIV and electrochemical) were combined in order to obtain complex data containing fluid velocity fields around tubes and the heat transfer coefficient on tubes' surface. Keywords: two-phase flow, heat transfer, electrochemical method, DPIV
Źródło:
Inżynieria i Aparatura Chemiczna; 2012, 6; 328-329
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental investigation of heat transfer characteristics of nanofluid using parallel flow, counter flow and shell and tube heat exhanger
Badanie eksperymentalne charakterystyk przewodzenia ciepła w nanopłynach w warunkach przepływu współprądowego i przeciwprądowego w płaszczowych i rurowych wymiennikach ciepła
Autorzy:
Dharmalingam, R.
Sivagnanaprabhu, K. K.
Yogaraja, J.
Gunasekaran, S.
Mohan, R.
Powiązania:
https://bibliotekanauki.pl/articles/950690.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
logarithmic mean temperature difference
heat exchanger
Nusselt number
nanofluids
overall heat transfer coefficient
średnia logarytmiczna różnica temperatur
wymiennik ciepła
liczba Nusselta
nanopłyny
współczynnik przenikania ciepła
Opis:
Cooling is indispensable for maintaining the desired performance and reliability over a very huge variety of products like electronic devices, computer, automobiles, high power laser system etc. Apart from the heat load amplification and heat fluxes caused by many industrial products, cooling is one of the major technical challenges encountered by the industries like manufacturing sectors, transportation, microelectronics, etc. Normally water, ethylene glycol and oil are being used as the fluid to carry away the heat in these devices. The development of nanofluid generally shows a better heat transfer characteristics than the water. This research work summarizes the experimental study of the forced convective heat transfer and flow characteristics of a nanofluid consisting of water and 1% Al2O3 (volume concentration) nanoparticle flowing in a parallel flow, counter flow and shell and tube heat exchanger under laminar flow conditions. The Al2O3 nanoparticles of about 50 nm diameter are used in this work. Three different mass flow rates have been selected and the experiments have been conducted and their results are reported. This result portrays that the overall heat transfer coefficient and dimensionless Nusselt number of nanofluid is slightly higher than that of the base liquid at same mass flow rate at same inlet temperature. From the experimental result it is clear that the overall heat transfer coefficient of the nanofluid increases with an increase in the mass flow rate. It shows that whenever mass flow rate increases, the overall heat transfer coefficient along with Nusselt number eventually increases irrespective of flow direction. It was also found that during the increase in mass flow rate LMTD value ultimately decreases irrespective of flow direction. However, shell and tube heat exchanger provides better heat transfer characteristics than parallel and counter flow heat exchanger due to multi pass flow of nanofluid. The overall heat transfer coefficient, Nusselt number and logarithmic mean temperature difference of the water and Al2O3 /water nanofluid are also studied and the results are plotted graphically.
Chłodzenie jest niezbędne dla właściwego funkcjonowania i niezawodności różnorodnych produktów, jak urządzenia elektroniczne, komputery, samochody, systemy laserowe wielkiej mocy, itp. W sytuacji wzrostu obciążenia cieplnego i strumieni ciepła wytwarzanych przez urządzenia przemysłowe, chłodzenie jest jednym z najważniejszych wyzwań występujących w różnych gałęziach przemysłu, transporcie, mikroelektronice, itp. Płynami, które zwykle są używane do odprowadzania ciepła z tych urządzeń są woda, glikol etylenowy i oleje. Nanopłyny, opracowane w ostatnim czasie, wykazują generalnie lepsze charakterystyki przewodnictwa cieplnego niż woda. Przedstawiona praca stanowi podsumowanie badań doświadczalnych nad wymuszonym, konwekcyjnym odprowadzaniem ciepła i charakterystykami przepływu nanopłynu składającego się z wody i cząsteczek Al2O3 (w 1% stężeniu objętościowym) w warunkach laminarnego przepływu współprądowego i przeciwprądowego w płaszczowych i rurowych wymiennikach ciepła. W przedstawionych badaniach użyto cząstek Al2O3 o średnicy ok. 50 nm. Wybrano trzy różne prędkości przepływu masy, opisano wyniki eksperymentów. Wyniki te wskazują, że całkowity współczynnik odprowadzania ciepła i bezwymiarowa liczba Nusselta nanopłynu są, przy tej samej prędkości przepływu masy i temperaturze na wlocie, nieznacznie wyższe, niż dla samego płynu bazowego. Z wyników doświadczalnych wynika, że całkowity współczynnik odprowadzania ciepła wzrasta wraz z prędkością przepływu masy. Pokazano, że gdy wzrasta prędkość przepływu masy, całkowity współczynnik odprowadzania ciepła wraz z bezwymiarową liczbą Nusselta ostatecznie wzrastają, niezależnie od kierunku przepływu. Stwierdzono także, że ze wzrostem prędkości przepływu masy wartość LMTD (średniej logarytmicznej różnicy temperatur) ostatecznie maleje, niezależnie od kierunku przepływu. Niemniej, płaszczowe i rurowe wymienniki ciepła zapewniają lepsze charakterystyki odprowadzania ciepła niż wymienniki z przepływem współprądowym i przeciwprądowym, co wynika z wielostrumieniowego przepływu nanopłynu. Badano także całkowity współczynnik odprowadzania ciepła, bezwymiarową liczbę Nusselta i średnią logarytmiczną różnicę temperatur dla wody i nanopłynu złożonego z wody i Al2O3, a wyniki przedstawiono w formie graficznej.
Źródło:
Archive of Mechanical Engineering; 2015, LXII, 4; 509-522
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Behaviour of a non-newtonian fluid in a helical tube under the influence of thermal buoyancy
Autorzy:
Ramla, Mohamed
Laidoudi, Houssem
Bouzit, Mohamed
Powiązania:
https://bibliotekanauki.pl/articles/2105993.pdf
Data publikacji:
2022
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
helical heat exchanger
mixed convection
forced convection
power-law fluids
Nusselt number
Opis:
This work is an evaluative study of heat transfer in the helical-type heat exchanger. The fluid used is non-Newtonian in nature and is defined by Oswald’s model. The work was performed numerically by solving each of the Navier–Stokes equations and the energy equation using the package ANSYS-CFX. Following are the aspects that have been dealt with in this paper: the effects of thermal buoyan-cy, fluid nature and the tube shape on the heat transfer, and the fluid comportment. The interpretation of the obtained results was done by analyzing the isotherms and the streamlines. The mean values of the Nusselt number were also obtained in terms of the studied parame-ters. The results of this research enabled us to arrive at the following conclusion: the intensity of thermal buoyancy and the nature of the fluid affect the heat transfer distribution but keep the overall rate of heat transfer the same.
Źródło:
Acta Mechanica et Automatica; 2022, 16, 2; 111--118
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identyfikacja struktur przy przepływie gaz - ciecz w wymienniku ciepła o niewielkich rozmiarach z wykorzystaniem cyfrowej anemometrii obrazowej DPIV
Identification of structures of gas - liquid flow in a small heat exchanger using the Digital Particle Image Velocimetry (DPIV) method
Autorzy:
Karaś, M.
Zając, D.
Ulbrich, R.
Powiązania:
https://bibliotekanauki.pl/articles/2071169.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przepływ dwufazowy gaz-ciecz
wymiennik ciepła
pęk rur
cyfrowa anemometria obrazowa
PIV
DPIV
gas-liquid two-phase flow
heat exchanger
tube bundle
digital image velocimetry
Opis:
Zjawisko przepływu gaz ciecz wokół pęku rur występuje w wielu procesach przemysłowych. W tej pracy przedstawiono przegląd najnowszych badań przepływu dwufazowego wokół pęku rur wykonanych techniką cyfrowej anemometrii obrazowej DPIV z wykorzystaniem kamer o dużej prędkości rejestracji obrazu w wysokiej rozdzielczości. Przedstawiono również wyniki badań własnych przepływu dwufazowego powietrze — woda w modelu płaszczowo rurowego wymiennika ciepła.
Two phase flow around a tube bundle exist in many industrial processes. The newest researches of two-phase flow around the tube bundle using the DPIV measuring method and high speed cameras are described in this paper. The experimental setup and measurements of air - water flow in the heat exchanger model are presented. Complexity of two-phase flow is shown using velocity fields and stream lines.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 3; 43-44
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metod korelacyjnych w badaniach przepływu dwufazowego gaz - ciecz w przestrzeni międzyrurowej wymiennika ciepła
Application of correlation methods in the research of two-phase gas - liquid flow in a tube bundle space of heat exchanger
Autorzy:
Guziałowska, J.
Skoczylas, D.
Ulbrich, R.
Powiązania:
https://bibliotekanauki.pl/articles/2070795.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przestrzeń międzyrurowa
przepływy dwufazowe
funkcja korelacji wzajemnej
model poślizgu
tube bundle space
two-phase flow
autocorrelation function
sli model
Opis:
W prezentowanej pracy podjęto próbę opisu hydrodynamiki przepływu mieszaniny gaz-ciecz w przestrzeni międzyrurowej wymiennika z przegrodami poprzecznymi. Stosując funkcję korelacji wzajemnej określono zmianę poziomu szarości w charakterystycznych punktach wymiennika ciepła. Następnie stosując model poślizgu wg Zube-ra-Findlaya obliczono prędkości struktur gazowych i porównano je z wartościami wyznaczonymi w oparciu o funkcję korelacji wzajemnej.
Investigations into two-phase gas - liquid flow hydrodynamics in a tube bundle space of heat exchanger with segmental baffles are presented in the paper. The grey level value in characteristic points of heat exchanger was determined using the autocorrelation function. The velocities of gas structures were calculated using the slip model proposed by Zuber-Findlay,
Źródło:
Inżynieria i Aparatura Chemiczna; 2009, 6; 78-80
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-28 z 28

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies