Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heat strain" wg kryterium: Wszystkie pola


Tytuł:
A Body Characteristic Index to Evaluate the Level of Risk of Heat Strain for a Group of Workers With a Test
Autorzy:
Lu, S.
Peng, H.
Gao, P.
Powiązania:
https://bibliotekanauki.pl/articles/89730.pdf
Data publikacji:
2014
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
heat environment
physical fitness
anthropometric characteristic
index
heat strain
środowisko cieplne
sprawność fizyczna
antropometria
Opis:
The purpose of this study was to develop a body characteristic index (BCI) based on the distribution of maximal oxygen uptake per body mass (VO2max/mass), body surface area per body mass (BSA/mass), and percentage of body fat (Fat%) to evaluate the relative level of individual physiological responses to heat strain in a group of workers. BCI was based upon the data obtained from 10 males and 10 females exercising for 60 min on a treadmill at 2 relative exercise intensities of 25% and 45% VO2max in mild, warm wet, and hot dry climate condition, separately. BCI was developed into 2 formulas, which were proved to be better predictors for heat strain responses than each individual characteristic, and more sensitive than body type to describe the distributions of individual characteristics and distinguish the differences in physiological responses to heat.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2014, 20, 4; 647-659
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie wyników badań obciążenia cieplnego człowieka w środowisku gorącym z wynikami otrzymanymi z symulacji numerycznej
Comparison the heat load as the results of tests on human subject in a hot environment with the results obtained from numerical simulation
Autorzy:
Sobolewski, Andrzej
Młynarczyk, Magdalena
Konarska, Maria
Bugajska, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/957060.pdf
Data publikacji:
2019
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
ekstremalne obciążenia cieplne
środowisko gorące i wilgotne
przewidywane obciążenie cieplne(PHS)
extreme heat loads
hot and humid environment
predicted heat strain (PHS)
Opis:
Porównanie wyników badań wykonanych w komorze klimatycznej z udziałem ochotników w warunkach otoczenia: ta = 42°C; RH = 80%; prężność pary wodnej = 6,56 kPa, V=0,5 m/s; z prognozami z symulacji numerycznej wykonanej programem PHS wykazały ich zadowalającą zgodność. Potwierdza to możliwość wykorzystania programu PHS do prognozowania obciążenia cieplnego człowieka w ekstremalnym środowisku gorącym, kiedy prężność pary wodnej w otaczającym środowisku przekracza wartość 4,5 kPa, przyjętą w normie PN-EN ISO 7933:2005 jako wartość maksymalną zakresu normy.
Comparison of the results of tests carried out in a climatic chamber with volunteers at ambient conditions: ta = 42°C, RH = 80%; the vapor pressure = 6.56 kPa, V = O 5 m/s, with predictions from numerical simulation made by the PHS program, they showed their satisfactory compatibility. This confirms the possibility of using the PHS program to predict the heat load of a human being in an extreme hot environment, when the vapor pressure in the surrounding environment exceeds 4 5 kPa, indicated in PN-EN ISO 7933 2005 as a limit value.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2019, 12; 24-27
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Equivalent climate temperature analysis as a criterion of climate hazard evaluation in Polish underground mines
Analiza temperatury zastępczej klimatu jako kryterium oceny zagrożenia klimatycznego w polskich kopalniach podziemnych
Autorzy:
Głuch, B.
Powiązania:
https://bibliotekanauki.pl/articles/219054.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ocena warunków mikroklimatu
zagrożenie klimatyczne
kopalnie podziemne
temperatura zastępcza klimatu
model przewidywanego strumienia cieplnego
model PHS
evaluation of microclimate conditions
climate hazard
underground mines
equivalent climate temperature
predicted heat strain model
PHS model
Opis:
The article discusses changes in Polish regulations concerning assessment of the climate hazard in underground mines. Currently, the main empirical index representing the heat strain, used in qualification of the workplace to one of the climate hazard levels in Poland is the equivalent climate temperature. This simple heat index allows easy and quick assessment of the climate hazard. To a major extent, simple heat indices have simplifications and are developed for a specific working environments. Currently, the best methods used in evaluation of microclimate conditions in the workplace are those based on the theory of human thermal balance, where the physiological parameters characterising heat strain are body water loss and internal core temperature of the human body. The article describes the results of research on usage of equivalent climate temperature to heat strain evaluation in underground mining excavations. For this purpose, the numerical model of heat exchange between man and his environment was used, taken from PN-EN ISO 7933:2005. The research discussed in this paper has been carried out considering working conditions and clothing insulation in use in underground mines. The analyses performed in the study allowed formulation of conclusions concerning application of the equivalent climate temperature as a criterion of assessment of climate hazards in underground mines.
W artykule omówiono zmiany w polskich przepisach dotyczących oceny zagrożenia klimatycznego w kopalniach podziemnych. Obecnie głównym wskaźnikiem zaliczenia stanowiska pracy do jednego ze stopni zagrożenia klimatycznego jest temperatura zastępcza klimatu. Ten prosty wskaźnik mikroklimatu umożliwia wykonanie, w łatwy i szybki sposób, oceny zagrożenia klimatycznego. Proste wskaźniki mikroklimatu w dużej mierze posiadają uproszczenia i są opracowane do konkretnego środowiska pracy. Najlepszymi obecnie metodami oceny warunków cieplnych pracy są metody oparte na teorii bilansu cieplnego człowieka, gdzie parametrami fizjologicznymi charakteryzującymi obciążenie cieplne jest ubytek wody z organizmu oraz temperatura wewnętrzna ciała. W artykule opisano wyniki badań nad zasadnością zastosowania temperatury zastępczej klimatu do oceny obciążenia cieplnego w wyrobiskach podziemnych. W tym celu wykorzystano model numeryczny wymiany ciepła między organizmem człowieka a otoczeniem, zaczerpnięty z normy PN-EN ISO 7933:2005. Omawiane badania zostały przeprowadzone przy uwzględnieniu ciężkości pracy oraz izolacyjności termicznej odzieży stosowanej w zakładach górniczych. Zrealizowane badania pozwoliły na sformułowanie wniosków dotyczących zastosowania temperatury zastępczej klimatu jako kryterium oceny zagrożenia klimatycznego w kopalniach podziemnych.
Źródło:
Archives of Mining Sciences; 2018, 63, 4; 975-988
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Age-Related Thermal Strain in Men While Wearing Radiation Protective Clothing During Short-Term Exercise in the Heat
Autorzy:
Marszałek, A.
Smolander, J.
Sołtyński, K.
Powiązania:
https://bibliotekanauki.pl/articles/90166.pdf
Data publikacji:
2004
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
age
heat
protective clothing
środowisko cieplne
ochrona przed ciepłem
promieniowanie podczerwone
zagrożenia zawodowe
różnice związane z wiekiem
Opis:
The aim of the study was to compare heat strain among different age groups of men in protective clothing during short-term physical work. Eight young (20-29 years), 6 middle-aged (41-55 years), and 6 older (58-65 years) men exercised for 30 min on a cycle ergometer (40% VO2 max) in 2 hot environments with a similar WBGT (ca. 26 ºC): once with minimal clothing without infrared radiation (E1), and once with aluminized protective clothing under infrared radiation (E2). All subjects had sedentary jobs, but only the older subjects were physically active in their leisure-time. Body temperatures, heart rate, sweat rate, and subjective feelings were determined during the tests. Higher thermal strain was observed in E2 than in E1. No age-related differences in thermal strain were observed in either experiment indicating that active older men can tolerate short work periods with protective clothing in the heat as well as younger sedentary men.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2004, 10, 4; 361-367
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Test of Firefighter’s Turnout Gear in Hot and Humid Air Exposure
Autorzy:
Holmer, I.
Kuklane, K.
Gao, C.
Powiązania:
https://bibliotekanauki.pl/articles/90221.pdf
Data publikacji:
2006
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
body temperature
heat stress
physiological strain
protective clothing
odzież ochronna
straż pożarna
pożar
temperatura powietrza
temperatura ciała
stres
zagrożenia zawodowe
strażak
Opis:
Five students of a rescue training school cycled at 50 W for 20 min at 20 oC before walking at 5 km/hr up to 30 min in a climatic chamber at 55 oC and 30% relative humidity. 4 different types of clothing ensembles differing in terms of thickness and thermal insulation value were tested on separate days. All subjects completed 28–30 min in light clothing, but quit after 20–27 min in 3 firefighter ensembles due to a rectal temperature of 39 oC or subjective fatigue. No difference in the evolution of mean skin or rectal temperature was seen for the 3 turnout ensembles. Sweat production amounted to about 1000 g in the turnout gears of which less than 20% evaporated. It was concluded that the small differences between the turnout gears in terms of design, thickness and insulation value had no effect on the resulting heat physiological strain for the given experimental conditions.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2006, 12, 3; 297-305
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of plastic strain localization on the basis of strain and temperature fields
Analiza lokalizacji odkształcenia plastycznego na podstawie pola odkształceń i pola temperatury
Autorzy:
Maj, M.
Oliferuk, W.
Powiązania:
https://bibliotekanauki.pl/articles/356157.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
plastic strain localization
strain field
temperature field
infrared thermography
heat transfer
Opis:
In the present paper the onset of plastic strain localization was determined using two independent methods based on strain and temperature field analysis. The strain field was obtained from markers displacement recorded using visible light camera. In the same time, on the other side of the specimen, the temperature field was determined by means of infrared camera. The objective of this work was to specify the conditions when the non-uniform temperature distribution can be properly used as the indicator of plastic strain localization. In order to attain the objective an analysis of strain and temperature fields for different deformation rates were performed. It has been shown, that for given experimental conditions, the displacement rate 2000 mm/min is a threshold, above which the non-uniform temperature distribution can be used as the indicator of plastic strain localization.
W niniejszej pracy początek lokalizacji odkształcenia plastycznego wyznaczono przy użyciu dwóch niezależnych metod bazujących na analizie pola odkształceń i pola temperatury. Pole odkształceń wyznaczono na podstawie przemieszczeń markerów zarejestrowanych przy użyciu kamery w świetle widzialnym. Jednocześnie, na przeciwległej powierzchni próbki wyznaczano pole temperatury przy użyciu kamery podczerwieni. Celem niniejszej pracy było określenie warunków, w których niejednorodny rozkład temperatury może być użyty, jako wskaźnik lokalizacji odkształcenia plastycznego. Aby osiągnąć postawiony cel, przeprowadzono analizę pola odkształceń i pola temperatury dla różnych prędkości deformacji. Pokazano, ze dla zadanych warunków eksperymentu, prędkość przemieszczenia 2000 mm/min, stanowi próg, powyżej którego niejednorodne pole temperatury może być używane, jako wskaźnik lokalizacji odkształcenia plastycznego.
Źródło:
Archives of Metallurgy and Materials; 2012, 57, 4; 1111-1116
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja konstrukcji wymiennika ciepła
Optimization of heat exchanger design
Autorzy:
Chudzik, A.
Powiązania:
https://bibliotekanauki.pl/articles/209915.pdf
Data publikacji:
2007
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
optymalizacja
wymiennik ciepła
wytrzymałość konstrukcji
odkształcenie plastyczne
optimization
heat exchanger
strength of construction
plastic strain
Opis:
Istotnym problemem w dnach sitowych wymienników ciepła jest zamocowanie rurek w płycie, np. przez rozwalcowanie. W wyniku tego procesu następuje trwałe odkształcenie plastyczne wokół otworów, co ma wpływ na kształt sąsiednich otworów, a następnie na pracę całej płyty i rurek. Dla konstruktorów wymiennika ciepła istotna jest analiza wytrzymałościowa połączenia, pozwalająca na określenie stanu naprężeń i przemieszczeń dna sitowego w jego warunkach pracy. Metoda elementów skończonych umożliwia wierne odwzorowanie konstrukcji, a także technologii wykonania i montażu wymiennika. W pracy przedstawiono obliczenia naprężeń i odkształceń dla różnych grubości dna sitowego.
For designers of heat exchangers, the strength analysis of the connection, which allows for determination of the state of stress and the calculation of displacements of the perforated bottom after fixing pipes in it, is of special importance. It results from the computations carried out that maximum reduced stresses in the perforated bottom are significantly lower than the values of admissible stresses. In this paper, the computations of stresses and strains for various thicknesses of the perforated bottom have been presented. As a result of decrease in the thickness of the perforated bottom, its deflection increases.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2007, 56, sp.1; 17-22
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Friction heating and stress-strain state of ventilated disc brakes
Autorzy:
Holenko, Kostyantyn
Dykha, Oleksandr
Babak, Oleg
Posonskiy, Sergiy
Powiązania:
https://bibliotekanauki.pl/articles/2204250.pdf
Data publikacji:
2023
Wydawca:
Fundacja Centrum Badań Socjologicznych
Tematy:
brake discs
thermal load
stress-strain state
safety
stress
heat flow
Opis:
This paper describes the study of ventilated car disc brakes stress-strain conditions and friction under the pressure using the ANSYS environment. Such influencing factors are taken into account in the course of research as angular speed value, the pressure of the pads on the disk, the nature of the load application, convection, thermal expansion, etc. Computer modelling of the stress field and the transient thermal field in the area of contact between the pads and the disk is provided by the method of sequential thermostructural communication of the intermediate states of the brake model directly in the ANSYS Coupled Field Transient environment. Besides, the ANSYS calculations were also performed based on the primitive assembly model of two steel blocks (the discrepancy was less than 3%) to determine the identity of the theoretical knowledge about the heating of bodies as a result of the work to overcome frictional forces. Finally, a high level of calculation results convergence by analytical formulas and computer modelling was established. Since this approach justified itself, its principles were taken as a basis in the calculations of ventilated disc brakes of cars, which significantly facilitates their application, knowing the area of the active part of the disc (the rest of the boundary conditions are typical and correspond to the normal operating modes of the vehicle).
Źródło:
Journal of Sustainable Development of Transport and Logistics; 2023, 8, 1; 43--52
2520-2979
Pojawia się w:
Journal of Sustainable Development of Transport and Logistics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plane strain deformation in a thermoelastic microelongated solid with internal heat source
Autorzy:
Ailawalia, P.
Sachdeva, S. K.
Pathania, D. S.
Powiązania:
https://bibliotekanauki.pl/articles/265041.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
thermoelasticity
microelongation
heat source
normal mode analysis
termosprężystość
źródło ciepła
odkształcenie
Opis:
The purpose of this paper is to study the two dimensional deformation due to an internal heat source in a thermoelastic microelongated solid. A mechanical force is applied along an overlaying elastic layer of thickness h. The normal mode analysis has been applied to obtain the exact expressions for the displacement component, force stress, temperature distribution and microelongation. The effect of the internal heat source on the displacement component, force stress, temperature distribution and microelongation has been depicted graphically for Green-Lindsay (GL) theory of thermoelasticity.
Źródło:
International Journal of Applied Mechanics and Engineering; 2015, 20, 4; 717-731
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical Modelling of Thermal and Structural Strain in Laser Welding Process
Modelowanie numeryczne odkształceń cieplnych i strukturalnych w procesie spawania techniką laserową
Autorzy:
Piekarska, W.
Kubiak, M.
Saternus, Z.
Powiązania:
https://bibliotekanauki.pl/articles/356199.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
laser welding
heat transfer
phase transformations
numerical modelling
isotropic strain
Opis:
This work concerns numerical modelling of thermal and structural strain, resulting in heating and cooling of laser butt-welded joints. Numerical analysis of strain is carried out in Abaqus FEA. Through the use of additional author's subroutines, the structural strain caused by phase transformations during heating and cooling of welded elements is taken into account in the analysis. V.I. Machnienko models as well as Continuous Heating Transformation (CHT) and Continuous Cooling Transformation (CCT) diagrams for S355 steel are implemented into UEXPAN subroutine in order to determine the kinetics of phase transformation in the solid state. The model takes into account thermomechanical properties of the base material varying with temperature. The paper presents results of numerical simulation of temperature field, predicted structural composition, thermal and structural strain in laser butt-welded joints.
W pracy przedstawiono numeryczne modelowanie odkształceń cieplnych i strukturalnych, powstających podczas nagrzewania i chłodzenia, złącza spawanego doczołowo wiązka promieniowania laserowego. Analizę numeryczna odkształceń przeprowadzono w programie Abaqus FEA. Dzięki zastosowaniu dodatkowych autorskich aplikacji w analizie uwzględniono odkształcenia strukturalne wywoływane przemianami fazowymi podczas nagrzewania i chłodzenia spawanych elementów. Do wyznaczenia kinetyki przemian fazowych w stanie stałym zastosowano modele V.I. Machnienki oraz wykresy CTPA i CTPc-S dla stali S355 implementowane do procedury UEXPAN. W modelu uwzględniono zmienne z temperatura własności termomechaniczne spawanego materiału. Przedstawiono wyniki symulacji numerycznych pola temperatury, prognozowanego numerycznie składu strukturalnego oraz odkształceń termicznych i strukturalnych w złączu spawanym doczołowo wiązka promienia laserowego.
Źródło:
Archives of Metallurgy and Materials; 2012, 57, 4; 1220-1227
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies