Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "hadrontherapy" wg kryterium: Wszystkie pola


Wyświetlanie 1-4 z 4
Tytuł:
Application of instruments of nuclear physics to the calculation of theoretical dose distributions in various organs of the human body for beams used in hadrontherapy
Autorzy:
Maliszewska, W.
Sękowski, P.
Skwira-Chalot, I.
Powiązania:
https://bibliotekanauki.pl/articles/146972.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
carbon ions
hadrontherapy
hydrogen ions
SRIM
Xeloss
Opis:
The area of interests of nuclear physics are studies of reactions, wherein atomic nuclei of projectile collide with target nuclei. An amount of energy lost by projectile nucleus during its passing through the target is a major issue – it is important to know how charged particles interact with matter. It is possible to afford this knowledge by using theoretical programs that calculate energy loss applying the Bethe-Bloch equation. Hadrontherapy, which is a field of still growing interest, is based on the interactions of charged particles with matter. Therefore, there exists a need of creating a simple model that could be used to the calculation of dose distributions in biological matter. Two programs (SRIM, Xeloss), used to the calculation of energy loss by nuclear physicist, have been adapted to determine the dose distributions in analogues of human tissues. Results of the calculations with those programs for beams used in hadrontherapy (e.g. 1H, 12C) will be compared with experimental data available in references.
Źródło:
Nukleonika; 2016, 61, 1; 19-22
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monte Carlo calculated CT numbers for improved heavy ion treatment planning
Autorzy:
Qamhiyeh, S.
Wysocka-Rabin, A.
Jäkel, O.
Powiązania:
https://bibliotekanauki.pl/articles/148658.pdf
Data publikacji:
2014
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
X-ray tomography
Monte Carlo (MC) method
treatment planning
hadrontherapy
Opis:
Better knowledge of CT number values and their uncertainties can be applied to improve heavy ion treatment planning. We developed a novel method to calculate CT numbers for a computed tomography (CT) scanner using the Monte Carlo (MC) code, BEAMnrc/EGSnrc. To generate the initial beam shape and spectra we conducted full simulations of an X-ray tube, filters and beam shapers for a Siemens Emotion CT. The simulation output files were analyzed to calculate projections of a phantom with inserts. A simple reconstruction algorithm (FBP using a Ram-Lak filter) was applied to calculate the pixel values, which represent an attenuation coefficient, normalized in such a way to give zero for water (Hounsfield unit (HU)). Measured and Monte Carlo calculated CT numbers were compared. The average deviation between measured and simulated CT numbers was 4 ± 4 HU and the standard deviation σ was 49 ± 4 HU. The simulation also correctly predicted the behaviour of H-materials compared to a Gammex tissue substitutes. We believe the developed approach represents a useful new tool for evaluating the effect of CT scanner and phantom parameters on CT number values.
Źródło:
Nukleonika; 2014, 59, 1; 15-23
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of computed tomography (CT) images using a Monte Carlo approach
Autorzy:
Wysocka-Rabin, A. M.
Qamhiyeh, S.
Jäkel, O.
Powiązania:
https://bibliotekanauki.pl/articles/147601.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
X-ray tomography
Monte Carlo (MC) method
treatment planning
hadrontherapy
Opis:
Heavy ion treatment planning uses an empirical scanner-dependent calibration relation between computed tomography (CT) numbers and ion range. Any deviation in the values of CT numbers will cause a drift in the calibration curve of the CT scanner, which can reduce the accuracy of treatment beam delivery. To reduce uncertainty in the empirical estimation of CT numbers, we developed a simulation that takes into consideration the geometry, composition, and physical process that underlie their measurement. This approach uses Monte Carlo (MC) simulations, followed by a simple filtered back-projection reconstruction. The MC code used is BEAMnrc/EGSnrc. With the manufacturer’s permission, we simulated the components (X-ray tube, associated filters and beam shapers) of a Siemens Emotion CT. We then generated an initial beam shape and spectra, and performed further simulations using the phantom with substitutes. We analyzed the resulting phase space file to calculate projections, taking into account the energy response of the CT detectors. Then, we applied a simple reconstruction algorithm to the calculated projections in order to receive the CT image.
Źródło:
Nukleonika; 2011, 56, 4; 299-304
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The INSIDE Project: Innovative Solutions for In-Beam Dosimetry in Hadrontherapy
Autorzy:
Marafini, M.
Attili, A.
Battistoni, G.
Belcari, N.
Bisogni, M.
Camarlinghi, N.
Cappucci, F.
Cecchetti, M.
Cerello, P.
Ciciriello, F.
Cirrone, G.
Coli, S.
Corsi, F.
Cuttone, G.
De Lucia, E.
Ferretti, S.
Faccini, R.
Fiorina, E.
Frallicciardi, P.
Giraudo, G.
Kostara, E.
Kraan, A.
Licciulli, F.
Liu, B.
Marino, N.
Marzocca, C.
Matarrese, G.
Morone, C.
Morrocchi, M.
Muraro, S.
Patera, V.
Pennazio, F.
Peroni, C.
Piersanti, L.
Piliero, M.
Pirrone, G.
Rivetti, A.
Romano, F.
Rosso, V.
Sala, P.
Sarti, A.
Sciubba, A.
Sportelli, G.
Voena, C.
Wheadon, R.
Del Guerra, A.
Powiązania:
https://bibliotekanauki.pl/articles/1402609.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.53.Bn
87.53.Jw
87.53.Kn
87.55.N-
87.55.ne
87.57.uq
Opis:
The INSIDE project addresses the online dose monitoring in particle therapy issue. The proposed detectors exploit the secondary neutral and charged particles emitted during the treatment by the irradiated volumes. The new detection techniques allow to return and online a measurement of the released dose and the Bragg peak position.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1465-1467
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies