Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ground-source heat pump" wg kryterium: Wszystkie pola


Wyświetlanie 1-12 z 12
Tytuł:
Performance Analysis of Systems Powered by a Ground Source Heat Pump
Autorzy:
Fidorów-Kaprawy, Natalia
Dudkiewicz, Edyta
Zhelykh, Vasyl
Powiązania:
https://bibliotekanauki.pl/articles/2174908.pdf
Data publikacji:
2022
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
heat pump
SCOP
heating ceiling
cooling ceiling
low-temperature radiator
climatic conditions in Poland
climatic conditions in Ukraine
Opis:
Heat pumps are known as zero-emission heating and cooling devices at the point of energy production. In order to exploit their advantages, they are combined with low-temperature heating systems. Using the example of a residential building in five climatic zones in Poland and one in Ukraine, systems analyses were carried out, in which heat into rooms is supplied in two different ways: low-temperature radiators and thermally active ceilings. The energy demand for heating, cooling and domestic hot water preparation was calculated. The seasonal coefficient of performance of the ground source heat pump was estimated to compare the systems. The results of the analysis confirmed that the thermo-active ceiling (with a flow temperature of 35°C) ensures a lower final energy demand when it works throughout the year in the heating and natural cooling mode compared to the low-temperature radiators (with a flow temperature of 45°C) which facilitate only the heating mode in the heating season. Performance analysis demonstrated differences in final electric energy demand from 8% in the I climatic zone to 9% in the V climatic zone in Poland and 10% in Ukraine.
Źródło:
Rocznik Ochrona Środowiska; 2022, 24; 294--306
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór podzespołów gruntowej pompy ciepła
The selection of subassemblies for a ground source heat pump
Autorzy:
Szreder, M.
Powiązania:
https://bibliotekanauki.pl/articles/77970.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
pompy cieplne
kolektory pionowe
kolektory poziome
sprezarki spiralne
parowniki
skraplacze
wspolczynnik efektywnosci energetycznej
badania eksperymentalne
wyniki badan
parametry eksploatacyjne
efektywnosc energetyczna
Opis:
W pracy zostały zaprezentowane wybrane zagadnienia dotyczące projektowania gruntowej pompy ciepła na podstawie publikowanych wyników badań. W celu weryfikacji przyjętej metodyki doboru poszczególnych podzespołów pompy ciepła zostały przeprowadzone badania eksperymentalne na stanowisku badawczym wyposażonym w gruntową pompę ciepła z kolektorami pionowymi.
The paper presents selected issues related to the design of a ground source heat pump based on published research results. In order to verify the adopted methodology of selection of the heat pump individual subassemblies experimental investigations were carried out on a test stand equipped with a ground source heat pump fitted with vertical collectors.
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2013, 15, 1
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat pumps
Autorzy:
Milius, Povilas
Krawczyk, Dorota Anna
Powiązania:
https://bibliotekanauki.pl/chapters/4179818.pdf
Data publikacji:
2019
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
ground-source heat pump
heat energy
compressor
condensation
throttle valve
Opis:
Geothermal energy is the heat from the Earth that can be recovered and exploited by man. Natural geothermal energy examples are hot springs, volcanoes and other thermal sources. Research showed that the Earth’s temperature was increasing with depth, under a gradient of 2-3°C/100m. It is a great resource, non-polluting, almost infinite source of clean and renewable energy. The heat originates from the Earth’s core temperature. The ground-source heat pump (GSHP) is able to use the low grade geothermal energy to heat and cool homes, schools, governmental and commercial buildings. The heat pump uses a relatively small amount of electricity to transport four times more heat energy to heat consumers.
Źródło:
Buildings 2020+. Energy sources; 145-180
9788365596727
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study of a heat pump ground collector
Badania wymiennika gruntowego pompy ciepła
Autorzy:
Szreder, M.
Powiązania:
https://bibliotekanauki.pl/articles/792689.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
ground source heat pump
vertical collector
spiral compressor
heat source
coefficient performance
heating system
power consumption
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2014, 14, 3
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania otworowego wymiennika ciepła w aspekcie ich parametrów cieplnych na potrzeby współpracy z pompą ciepła
Analysis parameters of heating – cooling installation with ground source heat pump in heating and passive cooling mode
Autorzy:
Pełka, G.
Luboń, W.
Kotyza, J.
Malik, D.
Powiązania:
https://bibliotekanauki.pl/articles/203804.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
gruntowe pompy ciepła
współczynnik przewodzenia ciepła
opór cieplny
otworowy wymiennik ciepła
geothermal heat pumps
coefficient of thermal conductivity
thermal resistance
hole heat exchanger
Opis:
Pompy ciepła pozyskujące energię z płytkich systemów geotermalnych są obecnie najbardziej efektywnymi urządzeniami grzewczo-chłodzącymi. Centrum Zrównoważonego Rozwoju i Poszanowania Energii WGGiOŚ AGH w Miękini prowadzi badania w zakresie pomp ciepła oraz otworowych wymienników ciepła. W celu kompleksowej realizacji badań opracowano przenośnie urządzenie do prowadzenia testów reakcji termicznej (TRT) dla otworowych wymienników ciepła. Koncepcja urządzenia zakładała wykorzystanie dostępnych, krajowych komponentów składowych, co miało zapewnić niski koszt budowy. Test reakcji termicznej gruntu pozwala na określenie efektywnego współczynnika przewodzenia ciepła, oporu cieplnego otworowego wymiennika ciepła oraz temperatury początkowej w wymienniku. Wykonane urządzenie testowano na wymiennikach testowych w Centrum w Miękini.
Geothermal heat pumps are the most efficient heating and cooling devices. The AGH Sustainable Development and Energy Saving Center in Miękinia conducts heat pump and borehole heat exchangers research. To do the complex research a portable thermal response test device was developed. The concept of this device assume the use of available, domestic parts with a low cost of the construction. Thermal response test allows to determine an effective ground heat transfer coefficient, borehole heat exchanger thermal resistance and undisturbed fluid temperature. The constructed device was tested on the borehole heat exchangers in the Miękinia Laboratory.
Źródło:
Technika Poszukiwań Geologicznych; 2018, R. 57, nr 2, 2; 93-106
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analyzing temperature changes in the ground massif with a horizontal heat exchanger in the course of the heating season
Autorzy:
Adamovsky, R.
Neuberger, P.
Sed'ova, M.
Powiązania:
https://bibliotekanauki.pl/articles/62442.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
temperature change
ground massif
horizontal heat exchanger
heating season
heat pump
ground source heat pump
heat transfer
energy potential
ground temperature
temperature distribution
Opis:
The article is devoted to temperature changes in the ground massif with the horizontal heat exchanger as an energy source for a heat pump. The article was aimed at analyzing temperature changes in the ground massif with the horizontal heat exchanger at the beginning, in the course of and at the end of the heating season. Another aim was to analyze temperature differences in the area of the horizontal exchanger and the reference lot. The heat flow utilized in the evaporator of heat pump was extracted from the ground exchanger (nominal output at the condenser was 10.5 kW). Temperatures of the ground massif with the horizontal heat exchanger were measured in its plane in depths of 0.75 m, 0.5 m and 0.25 m. The temperature inside the ground massif on the reference lot and ambient parameters were measured as well. It is obvious that the difference of energetic potentials inside the ground massif with the heat exchanger and on the reference lot is insignificant at the beginning of the heating season. During the heating season, the difference of ground massif energetic potentials increases; at the end it is constant. The difference of temperatures in horizontal planes was not significant at the beginning of the heating season; however, it gradually increased. Maximum differences were detected in the area of the heat exchanger. In higher strata, the difference between temperatures decreases. During a major part of the heating season, temperatures at pipes of the ground exchanger were negative. This fact affected amounts of heat extracted from the ground massif.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2010, 11
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ventilation system with ground heat exchanger
Autorzy:
Pisarev, V.
Rabczak, S.
Nowak, K.
Powiązania:
https://bibliotekanauki.pl/articles/123849.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ground heat exchanger
ventilation
heat pump
heat source
Opis:
Ventilation systems consume more and more energy because of the often complex treatment of the air supplied to closed spaces. Looking for sources of energy allow for significant savings costs, which often translate into renewable energy sources. One of the more popular solutions is to use energy from the ground by various methods. Known and relatively common solutions are based on ground heat exchanger and ground collector cooperating with a heat pump. The paper presents the possibility of cooperation ventilation system with ground air heat exchanger and heat pump both in summer and winter period. A number solutions of this type of system, supported by calculation examples and moist air transformation in the Moliere chart have been presented. Support ventilation system with renewable energy sources allows significant savings in operating as shown in the article.
Źródło:
Journal of Ecological Engineering; 2016, 17, 5; 163-172
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature changes in heat pump horizontal ground source
Autorzy:
Adamovsky, R.
Neuberger, P.
Sed'ova, M.
Powiązania:
https://bibliotekanauki.pl/articles/60337.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
temperature change
heat pump
ground massif
horizontal heat exchanger
heat potential
soil
thermal potential
heating period
ground temperature
temperature distribution
heat transfer
energy conservation
Opis:
The paper deals with assessment of thermal fields and temperature changes in ground massif with horizontal heat exchanger used as a heat source for a heat pump. Temperatures in the zone of the horizontal ground exchanger are compared with temperatures in a reference land. Changes of heat potential of the soil during the heating period are also assessed. Possibilities of recovery of thermal potential of the ground massif when utilizing vertical and horizontal exchangers are analyzed in the opening part of the paper. The results of the first verification indicated that average temperatures in the horizontal planes of the ground massif did not differ considerably with distance from the exchanger tube. Differences in average temperatures in reference and experimental lands confirmed sufficient heat potential of the ground massif even at the peak of the heating period. The differences in average temperatures reached up to 6.51 K in the end of the heating period while at the beginning of the heating period, the differences in average temperatures dropped to 1.35 K. The differences between maximum and minimum temperatures in the zone of the ground exchanger reached up to 1.9 K at the peak of the heating period and rose to 3.9 K at the beginning and end of the heating period. The first results of our measurements indicate the necessity of accumulation of thermal energy in the soil massif in the summer period like in case of the vertical exchangers.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 07
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ground as a source of heat for heat pumps
Autorzy:
Matysko, R.
Powiązania:
https://bibliotekanauki.pl/articles/95309.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
heat pump
ground heat exchanger
transient behavior
ground regeneration
pompa ciepła
wymiennik ciepła gruntowy
stan nieustalony
regeneracja gruntu
Opis:
Heat pumps are an ideal solution for use in newly built passive and energy-plus buildings. One of the many problems present in such construction is the choice of the operational parameters of the lower heat source and the selection of a ground regeneration system which would enable effective regeneration in a short period of time and at a minimal cost. This article presents the heat analysis of the ground from which heat is obtained for heating purposes. The author also analyses ground heating, as the heat is delivered to it via regeneration systems. The presented in article results allow us to estimate the ground's thermal states based on lowered ambient temperature and the possible use of a lower heat pump source regeneration process. The original contribution in article is the calculation results of the ground behavior at the transient regeneration and heat consumption realized by the heat pump system.
Źródło:
Journal of Mechanical and Energy Engineering; 2018, 2, 2; 131-137
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena pracy wymienników ciepła ułożonych w różnych konfiguracjach zasilających pompę ciepła
Assessment of operaton of heat exchangers placed in various configurations feeding a heat pump
Autorzy:
Rutkowski, K.
Pasternak, W.
Powiązania:
https://bibliotekanauki.pl/articles/287616.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
pompa ciepła
wymiennik
dolne źródło ciepła
grunt
heat pump
exchanger
lower heat source
ground
Opis:
W pracy przedstawiono analizę energetyczną poziomych gruntowych wymienników pompy ciepła. Przeprowadzono analizę trzech typów wymienników wykonanych z rur polietylenowych, ułożonych w gruncie w kształcie pojedynczego U podwójnego U oraz spiralnie. Wymienniki posadowione były na głębokości od 1,5 do 2,3 m. Określono wydajność cieplną wymienników przy zróżnicowanym zapotrzebowaniu energii. Dla istniejących warunków badań okazało się, że największą ilość energii uzyskuje się w wymienniku poziomym, ułożonym w konfiguracji podwójnego U, którego średnia jednostkowa wydajność mocy grzewczej wynosiła 21,5 W z 1 mb rury. Moc jednostkowa uzyskiwana z pozostałych dwóch wymienników była średnio o 40% mniejsza i wahała się w zakresie 8 do 17 W z 1 mb rury.
The paper presents the energy analysis of horizontal ground exchangers of a heat pump. Three types of exchangers made of polyethylene pipes, placed in the ground single U, double U and spirally shaped were analysed. Exchangers were placed in the depth from 1.5 to 2.3 m. Thermal capacity of exchangers at varied energy demand was determined. For the existing research conditions, it was proved that the highest amount of energy is obtained in the horizontal exchanger placed in the double U configuration, the average unit thermal power capacity of which was 21.5 W from 1 current meter of a pipe. The unit power obtained from the remaining two exchangers was at the average by 40% lower and was within the range 8 to 17 W from 1 current meter of a pipe.
Źródło:
Inżynieria Rolnicza; 2013, R. 17, nr 3, t. 2, 3, t. 2; 301-308
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metodyczne aspekty doboru dolnego źródła pompy ciepła do ogrzewania tunelu foliowego
Methodical aspects of selecting a heat pump source for heating a foil tunnel
Autorzy:
Rutkowski, K.
Kurpaska, S.
Latała, H.
Powiązania:
https://bibliotekanauki.pl/articles/289613.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
pompa ciepła
pionowy wymiennik gruntowy
wydajność ciepła
tunel foliowy
heat pump
vertical ground exchanger
calorific effect
Opis:
W pracy przeprowadzono teoretyczną analizę wydajności pionowego dolnego wymiennika pompy ciepła wykonanego z rur polietylenowych zasilającego tunel foliowy. Dostosowano metodykę obliczeń do warunków obiektu badań. Do obliczeń wykorzystano wartości temperatury gruntu na zróżnicowanych głębokościach.
The work includes theoretical analysis of efficiency of the vertical lower heat pump exchanger made from polyethylene pipes supplying the foil tunnel. The calculation methodology was adapted to the conditions of the tested object. For calculations values of the soil temperature for different depths were used.
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 11(86), 11(86); 409-416
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza energetyczna dolnych źródeł ciepła pompy grzewczej przy ogrzewaniu tunelu foliowego
Energy analysis for lower heat sources of heating pump while heating a plastic tunnel
Autorzy:
Kurpaska, S.
Powiązania:
https://bibliotekanauki.pl/articles/291570.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tunel foliowy
ogrzewanie
górne źródło ciepła
wymienniki gruntowe
moc grzewcza
pompa ciepła
plastic tunnel
heating
ground exchangers
upper heat source
heat pomp
heating power
Opis:
W pracy analizowano wydajność grzewczą dolnego i górnego źródła ciepła współpracujących ze sprężarkową pompą ciepła. Określono zmienność wydajności w funkcji różnicy temperatury między zasilaniem a powrotem czynnika obiegowego. Stwierdzono, że w badanych warunkach analizy cyklów pracy pompy ciepła, konieczna jest modyfikacja odbioru energii z górnego źródła.
The paper contains an analysis of heating efficiency for lower and upper heat sources, which work with compressor-type heat pump. The researchers determined efficiency variability in the function of temperature difference between circulating medium supply and return. It was proved that in the examined conditions of heat pump working cycle analysis it is requisite to modify the system for receiving energy from upper source.
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 9 (97), 9 (97); 103-110
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies