Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "gas absorption" wg kryterium: Wszystkie pola


Tytuł:
Gamma-ray computed tomography SCANNERS for applications in multiphase system COLUMNs
Autorzy:
Calvo, W. A. P.
Hamada, M. M.
Sprenger, F. E.
Vasquez, P. A. S.
Rela, P. R.
Martins, J. F. T.
de Matos Pereira, J. C. S.
Omi, N.
de Mesquita, C. H.
Powiązania:
https://bibliotekanauki.pl/articles/148082.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
industrial computed tomography
multiphase flow systems
non-destructive testing
gas absorption column
industrial process optimization
packed distillation columns
scanning systems
Opis:
Gamma-ray tomography experiments have been carried out to detect spatial patterns in the porosity, in a 0.27 m diameter packed steel column using a first generation computed tomography (CT) system. The CT scanner consists of a NaI(Tl) detector 5.08 cm in diameter, and an encapsulated 137Cs (3.7 GBq) radioactive source, located opposite to the center of the detector. The detector and the source, mounted on a fixed support and the column, can rotated and dislocate by two stepping motors controlled through a microprocessor. Different sizes of stainless steel Raschig rings (12.6, 37.9 and 76 mm) have been examined. The primary objective of this work is to detect spatial patterns and statistical information on porosity variation in packed distillation columns. Horizontal scans, at different vertical positions of the packed bed were made for each size of Raschig rings. Radial porosity variation within the packed bed has been determined. This study has demonstrated that the porosity and its spatial distribution in a metallic packed column can be measured with adequate spatial resolution using the gamma-ray tomography technique. After validation of this first generation CT, the turntable design to rotate and dislocate the 60Co or 137Cs sealed gamma-ray sources and multidetector array for the third generation industrial computed tomography was also developed.
Źródło:
Nukleonika; 2009, 54, 2; 129-133
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous removal of NOx, SO2, CO and Hg from flue gas by ozonation. Pilot plant studies
Autorzy:
Głomba, M.
Kordylewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/950039.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
carbon dioxide
flue gases
ozone
ozonization
pilot plants
sulfur dioxide
gas absorption
NOx removal
So2 removal
CO removal
dwutlenek węgla
tlenki azotu
spaliny
ozon
ozonowanie
instalacje pilotażowe
dwutlenek siarki
absorpcja gazu
usuwanie NOx
usuwanie SO2
usuwanie CO
Opis:
The results of pilot plant investigations of simultaneous removal of NOx, SO2 and Hg from flue gas with ozone as the oxidizing agent and the spray tower absorber with NaOH solution as the absorbent have been presented. Flue gas was delivered into the pilot plant at the flow rate of 200 m3/h from the coal fired OP-430 boiler. The effectiveness of NOx removal was over 95% when the molar ratio O3/NO reached 2.0. Sulfur dioxide was practically completely washed out from flue gas in the absorber at the liquid-to-gas ratio 7.5 dm3/m3. The effectiveness of Hg removal in the studied system was approximately 80%. It was pointed out that CO concentration in flue gas could considerably increase the ozone consumption. The effect of carbon dioxide in flue gas on the chemistry of absorption due to hydroxides conversion into carbonates and bicarbonates was noticed.
Źródło:
Environment Protection Engineering; 2014, 40, 3; 113-125
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Limitations of the Generalized Coupled Two-Level Model during the Multiphoton Absorption in Different Gas Mixtures
Autorzy:
Nikolić, J.
Rabasović, M.
Markushev, D.
Powiązania:
https://bibliotekanauki.pl/articles/1815469.pdf
Data publikacji:
2007-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
39.30.+w
82.80.Kq
07.57.Ty
Opis:
Generalized coupled two-level model is applied in different gas mixtures and investigated for high fluence regime. Functional dependences of mean number of absorbed photons per molecule$ 〈n〉_\text{total}$ on buffer-gas pressure $(p_\text{buff})$ are presented, used to confirm or predict some possible physical and chemical processes, like enhanced absorption and/or dissociation. Limitations of proposed models are analyzed depending on both gas pressure and laser fluence. Results are compared with other previously obtained by the same experimental technique, but for different absorbing molecule.
Źródło:
Acta Physica Polonica A; 2007, 112, 5; 811-816
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pilot-scale studies on NOx removal from flue gas via NO ozonation and absorption into NaOH solution
Autorzy:
Jakubiak, M.P.
Kordylewski, W.K.
Powiązania:
https://bibliotekanauki.pl/articles/185772.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
tlenek azotu
ozonowanie
absorpcja
ozonation
absorption
nitric oxide
deNOx
Opis:
The paper presents results of experimental studies on removal of NOx from flue gas via NO ozonation and wet scrubbing of products of NO oxidation in NaOH solutions. The experiment was conducted in a pilot plant installation supplied with flue gas from a coal-fired boiler at the flow rate 200 m3/h. The initial mole fraction of NOx,ref in flue gas was approx. 220 ppm, the molar ratio X = O3/NOref varied between 0 and 2.5. Ozone (O3 content 1-5% in oxygen) was injected into the flue gas channel before the wet scrubber. The effect of the mole ratio X, the NaOH concentration in the absorbent, the liquid-to-gas ratio (L/G) and the initial NOx concentration on the efficiency of NOx removal was examined. Two domains of the molar ratio X were distinguished in which denitrification was governed by different mechanisms: for X > 1.0 NO2 undergoes further oxidation to higher oxides being efficiently absorbed in the scrubber. At the stoichiometric conditions (X = 1) the effectiveness of NO oxidation was better than 90%. However, the effectiveness of NOx removal reached only 25%. When ozonation was intensified (X >/= 2.25) about 95% of NOx was removed from flue gas. The concentration of sodium hydroxide in the aqueous solution and the liquid-to-gas ratio in the absorber had little effect on the effectiveness of NOx removal for X > 2.
Źródło:
Chemical and Process Engineering; 2012, 33, 3; 345-358
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on products of simultaneous removal of SO2 and NOx from flue gas by ozonation and alkaline absorption
Autorzy:
Głomba, M.
Hałat, A.
Kordylewski, W.
Łuszkiewicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/206900.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
soda kaustyczna
instalacja kogeneracyjna
spaliny
związki azotu
ozonowanie
instalacje pilotażowe
dwutlenek siarki
caustic soda
cogeneration plants
exhaust gases
flue gases
nitrogen compounds
ozonization
pilot plants
sulfur dioxide
Opis:
The results of laboratory scale research have been presented on the effects of ozonation of carrier gas containing NOx and SO2 on by-products trapped in Dreschel washers with solution of sodium hydroxide. The controlling parameter in this process was the ozonation intensity determined by the molar ratio O3/NOx. The measured by-products in a scrubber were SO32- , SO42- , NO2- and NO3- ions. It has been shown that ozonation of flue gas favours oidation of nitrites to nitrates and sulfites to sulfates in alkaline solution. Some of these results were confirmed in a pilot scale studies. Pilot plant was located in Wroclaw CHP (Combined Heat and Power), which provided flue gas for testing at a rate of 200 m3/h from the OP-430 boiler. Exhaust gases were ozonized and captured simultaneously with SO2. Sodium hydroxide was used in a pilot scale as an absorbent.
Źródło:
Environment Protection Engineering; 2016, 42, 2; 125-136
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reactions of nitrogen oxides and ozone in the gas phase followed by absorption process
Reakcje tlenków azotu i ozonu w fazie gazowej oraz absorpcja produktów reakcji
Autorzy:
Skalska, K.
Miller, J. S.
Ledakowicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/126069.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
nitrogen oxides
emission control
ozonation
tlenki azotu
kontrola emisji
ozonowanie
Opis:
The growing emissions of nitrogen oxides into atmosphere endanger the human health and degrade our environment. The presence of nitrogen oxides in the atmosphere is responsible for troposphere ozone and urban photochemical smog. NO and NO2 (NOx) are one of the major contributors to harmful acid rains. Various methods exist to reduce NOx emission. Combustion modification and selective catalytic reduction (SCR) are probably the most widely used techniques to control NOx emissions from industry. New technologies such as nonthermal plasma and pressure swing adsorption appear to be efficient for the removal of higher concentrations of NOx but they are still expensive for the treatment of huge volumes of flue gases. Thus, there is a need for environmentally friendly and cost effective methods for treatment of flue gases. One of the solutions to NOx emission problem can be to couple ozonation process in the gas phase with SCR or absorption process. In this work the application of ozone for the oxidation of nitrogen oxides present in exhaust gases was presented. The main concept of the process is to oxidize nitrogen oxide (NO) and nitrogen dioxide (NO2) into nitrogen pentoxide (N2O5) which reacts with water giving nitric acid. This way NOx can be absorbed in water with good effectiveness. In presented studies the influence of nitrogen(II) oxide initial concentration on the NO conversion was studied. Furthermore, the two stage process composed of the ozonation process of NOx and the absorption of reaction gases in the 0.01 M solution of NaOH was performed. These experiments proved that the yield of absorption process is higher for gases containing N2O5.
Rosnąca emisja tlenków azotu do atmosfery zagraża zdrowiu ludzi, a także przyczynia się do degradacji środowiska naturalnego. Obecność tlenków azotu w atmosferze może prowadzić do powstawania ozonu troposferycznego oraz smogu fotochemicznego. NOx (NO oraz NO2) są jednymi z głównych zanieczyszczeń przyczyniających się do występowania kwaśnych deszczów. Modyfikacje procesu spalania oraz selektywna katalityczna redukcja (SCR) są prawdopodobnie najczęściej stosowanymi metodami ograniczania emisji tlenków azotu ze źródeł przemysłowych. Nowe technologie, takie jak niskotemperaturowa plazma i adsorpcja zmiennociśnieniowa, wydają się być skuteczne przy usuwaniu wysokich stężeń NOx, jednak są one nadal drogie w szczególności w przypadku oczyszczania dużych strumieni gazów odlotowych. Dlatego istnieje konieczność opracowania przyjaznych środowisku i tanich metod ograniczania emisji zanieczyszczeń do atmosfery. Jednym z rozwiązań może być zastosowanie technologii łączącej proces ozonowania w fazie gazowej z selektywną katalityczną redukcją (SCR) bądź procesem absorpcji. W niniejszej pracy przedstawiono wykorzystanie ozonu w procesie utleniania tlenków azotu obecnych w gazach odlotowych. Głównym założeniem jest utlenienie monotlenku azotu (NO) i ditlenku azotu (NO2) do pentatlenku diazotu (N2O5), który ulega reakcji z wodą, dając kwas azotowy. W ten sposób NOx mogą być absorbowane w wodzie z dobrą wydajnością. Zbadano wpływ początkowego stężenia NO oraz stosunku NO/NO2 w gazach reakcyjnych na stopień konwersji NO oraz selektywności do produktów. Ponadto przeprowadzono eksperymenty w układzie dwustopniowym, składającym się z procesu ozonowania i absorpcji gazów reakcyjnych w 0,01 M roztworze NaOH. Otrzymane wyniki potwierdzają, że wydajność absorpcji jest wyższa w przypadku gazów zawierających N2O5.
Źródło:
Proceedings of ECOpole; 2011, 5, 2; 425-429
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detektor gazów z wykorzystaniem absorpcji fal elektromagnetycznych w zakresie środkowej podczerwieni
Gas detector based on the absorption of electromagnetic waves in the range of middle infrared
Autorzy:
Nowrot, A.
Powiązania:
https://bibliotekanauki.pl/articles/187680.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
detektory gazów
absorpcja fal elektromagnetycznych
gas detectors
absorption of electromagnetic waves
Opis:
Jedna z najefektywniejszych metod badania składu chemicznego gazów wykorzystuje absorpcję fal elektromagnetycznych w zakresie podczerwieni (infrared - IR). Przyrządy wykorzystujące to zjawisko od dawna są powszechnie stosowane w laboratoriach i umożliwiają wykrycie równocześnie bardzo wielu związków. Niestety są to urządzenia o dużych wymiarach i nie są przystosowane do pracy w atmosferze wybuchowej. Detektor gazów, którego koncepcja zostanie przedstawiona w niniejszym artykule, umożliwi oznaczenie stężenia tylko kilku wybranych związków w atmosferze np. metanu, lecz jednocześnie będzie się cechował mniejszymi wymiarami oraz dużo mniejszym poborem mocy w stosunku do urządzeń laboratoryjnych. Ponadto może zostać zaadaptowany do pracy w atmosferze wybuchowej. Projektowany detektor będzie pracował w zakresie środkowej podczerwieni, gdzie metan wykazuje najsilniejszą absorpcję promieniowania lR. Rozwiązanie to umożliwi uzyskanie większej czułości przyrządu w stosunku do dostępnych w handlu urządzeń tego typu wykorzystujących bliską podczerwień. Na podstawie przeprowadzonych badań, stanie się możliwe skonstruowanie w przyszłości komercyjnego nowoczesnego czujnika różnych gazów, konkurencyjnego wobec standardowych technologii.
One of the most efficient methods to examine the chemical composition of gases is the method which makes use of the absorption of electromagnetic waves in the range of infrared. The instruments which use this phenomenon have been commonly applied in laboratories and enable to detect many chemical compounds simultaneously. Unfortunately, these are large-size devices and are not adapted to work in explosion atmospheres. The gas detector presented in this article will enable to determine the concentration values of only few selected compounds in the atmosphere, e.g. methane. Yet, at the same time, it will have a smaller size and lower power consumption in comparison with laboratory apparatus. Additionally, the detector can be adapted to work in explosion atmospheres. The developed detector will work in the range of middle infrared where methane shows the strongest absorption of infrared radiation. This solution will allow to have a device which is more sensitive than near-infrared devices available on the market. Based on the conducted research it will be possible to develop a commercial version of a modern multi-gas detector which is going to be competitive with standard technologies.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2011, R. 49, nr 5, 5; 23-26
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling study of flue gas flow pattern with pressure, amount and shape variation catalytic converter
Autorzy:
Ghofur, A.
Isworo, H.
Subagyo, R.
Tamjidillah, M.
Siswanto, R.
Ma’ruf, -
Purwanto, H.
Muchsin, -
Powiązania:
https://bibliotekanauki.pl/articles/1818507.pdf
Data publikacji:
2020
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
shape effect
absorption effectiveness
ANSYS
catalytic converter
filter-not- cut
filter-cut
efekt kształtu
skuteczność wchłaniania
katalizator
Opis:
Purpose: The purpose of this study is to analyse the modelling of exhaust gas flow patterns with variations in pressure, number, and shape of filters on the catalytic converter. Design/methodology/approach: The research method used is a simulation using ANSYS, which starts by creating a converter catalytic model with pressure variations: (0.5-1.5 atm), number of filters: (2-5), and the form of filter-cut/filter-not-cut. Findings: The decrease in velocity is caused by non-uniform velocity in the exhaust gas flow that occurs when passing through a bend in the filter-cut that serves as a directional flow to create turbulence. Filter-cut type tends to have fluctuating pressure, turbulence flow pattern shape so that contact between filter and exhaust gas is more effective. Based on the analysis of flow patterns, the speed and pressure of the 5 filter-not-cut design at a pressure of 0.5 are the best, while at pressure (1-1.5 atm) the type 5 filter-cut is the best. Research limitations/implications: This study is limited to filter-not-cut and filter-cut types with variations in the number of filters: 2, 3, 4, and 5, and the inlet pressure between 0.5-1 atm. Practical implications: The practical implications of this study are to find a catalytic converter design that has advantages in the effectiveness of exhaust gas absorption. Originality/value: The results show that the filter-not-cut and filter-cut types have the best effectiveness in the number of 5 filters. Filter-not-cut at the pressure of 0.5 atm and filter-cut at pressure (1-1.5 atm).
Źródło:
Archives of Materials Science and Engineering; 2020, 103, 1; 5--17
1897-2764
Pojawia się w:
Archives of Materials Science and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
Autorzy:
Dobrzyniewski, Dominik
Szulczyński, Bartosz
Gębicki, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2202183.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
gas sensor
sensor array
absorption
deodorization
process control
Opis:
This article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization detector (GC-FID) was used as a reference analytical technique, which enabled to obtain reliable quantitative determinations of toluene concentration in the samples. A commercially available absorption liquid dedicated to non-polar compounds was used as an absorbent. The process was carried out in two identical systems: in first, pure toluene was absorbed and in the second, toluene vapor contaminated with acetone. This approach allowed verifying the selectivity of the prepared MLR calibration model for process control in the case of the presence of more or less expected pollutants in the treated gas. The results obtained with the gas sensor array were related to the reference technique and they confirm the usefulness and advisability of using these devices to monitor the absorption processes as a cheaper and more time-efficient alternative to chromatographic methods. The root mean square error (RMSE) in absorptivity determination between the results received with the analytical and sensor techniques was 0.019 and 0.041 when treating pure toluene vapors and its vapors with acetone, respectively. Compared to instrumental techniques, sensor matrices are technologically less complex, useful for laboratory purposes, as well as showing application potential for field studies. However, it is necessary to develop more sensitive and selective chemical gas sensor arrays and better master advanced data processing and identification techniques.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 269--282
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental study of the membrane contactor systems for gas dehumidification
Autorzy:
Usachov, V.
Laguntsov, N.
Okunev, A.
Teplyakov, V.
Glukhov, S.
Powiązania:
https://bibliotekanauki.pl/articles/346999.pdf
Data publikacji:
2003
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydział Technologii i Inżynierii Chemicznej
Tematy:
gas/vapour separation
dehumidification
polymeric membranes
membrane absorption
membrane contactor
Opis:
The paper presents a pilot active membrane contactor system (AMCS) description and experimental results for air dehumidification. Triethyleneglycol was used as a hygroscopic liquid carrier. Polydimethylsiloxane based membranes (Lestosil) were used in a spiral wound membrane contactor. The experiments with AMCS demonstrated effective air-drying under a high ratio-feed gas flux/liquid carrier flux (10²-10³). The developed contactor system allows to achieve air dehumidification up to Tdew point= –20 °C.
Źródło:
Ars Separatoria Acta; 2003, 2; 36-46
1731-6340
Pojawia się w:
Ars Separatoria Acta
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Absorption of CO2 into perfluorinated gas carrier in the Taylor gas–liquid flow in a microchannel system
Autorzy:
Sobieszuk, P.
Pilarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/185397.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
perfluorodecalin (PFD)
liquid gas carrier
solubility
Taylor flow
microreactor
perfluorodekalina (PFD)
gaz ciekły
rozpuszczalność
przepływ Taylora
mikroreaktor
Opis:
The aim of this study was to determine the solubility of CO2 in perfluorodecalin (PFD) which is frequently used as efficient liquid carrier of respiratory gases in bioprocess engineering. The application of perfluorinated liquid in a microsystem has been presented. Gas-liquid mass transfer during Taylor (slug) flow in a microchannel of circular cross section 0.4 mm in diameter has been investigated. A physicochemical system of the absorption of CO2 from the CO2/N2 mixture in perfluorodecalin has been applied. The Henry’s law constants have been found according to two theoretical approaches: physical (H = 1.22x10-3 mol/m3Pa) or chemical (H = 1.26x10-3 mol/m3Pa) absorption. We are hypothesising that the gas-liquid microchannel system is applicable to determine the solubility of respiratory gases in perfluorinated liquids.
Źródło:
Chemical and Process Engineering; 2012, 33, 4; 595-602
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigation of the two-dimensional gas temperature distribution based on tunable diode laser absorption spectroscopy
Autorzy:
Shao, J
Wang, L
Ying, C
Powiązania:
https://bibliotekanauki.pl/articles/174322.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
tomographic
modified adaptive algebraic reconstruction technique (MAART)
tunable diode laser absorption spectroscopy (TDLAS)
Opis:
Based on tunable diode laser absorption spectroscopy and modified adaptive algebraic reconstruction technique, two-dimensional tomographic reconstruction was derived for the gas temperature distribution in the range of 600–1400 K in the controlled projections. It is explicitly shown that the quality of temperature reconstruction is heavily dependent on the relative sensitivity of the selected spectrum and the algorithm of modified adaptive algebraic reconstruction technique but independent of the complexity of the present field distribution. When the relative sensitivity is less than 1.5, the accuracy of reconstruction relates to the relative sensitivity of the selected spectrum and improves with the increase in relative sensitivity. When the relative sensitivity is larger than 1.5, the accuracy is mainly limited by the algorithm of modified adaptive algebraic reconstruction technique.
Źródło:
Optica Applicata; 2015, 45, 2; 183-198
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model matematyczny hydrodynamiki wirnikowo-błonowego aparatu absorpcyjnego do oczyszczania gazów
Mathematical model of hydrodynamics in a rotor-film absorption apparatus used in gas cleaning
Autorzy:
Wilkocki, A
Volk, A
Powiązania:
https://bibliotekanauki.pl/articles/2072977.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
filmowy spływ cieczy
wirujący strumień gazu
oczyszczanie gazów
liquid film flow
swirling gas flow
gas cleaning
Opis:
Zaprezentowano nowy model matematyczny stacjonarnego laminarnego osiowo-symetrycznego ruchu warstwy lepkiej cieczy po wewnętrznej ściance pionowego cylindra pod wpływem wirującego strumienia gazu. Otrzymano analityczne rozwiązanie równań Naviera-Stokesa dla osiowej i stycznej prędkości cieczy. Znaleziono hydrodynamiczne właściwości przepływu filmu i analityczne warunki dla możliwych reżimów ruchu.
A new model of stationary laminar axially symmetric motion of viscous liquid film on the inner wall of vertical cylinder under the influence of swirling gas flow is presented. An exact analytical solution of the Navier - Stokes equations was found for axial and tangential velocity components. The hydrodynamic characteristics of film flow and analytical conditions for possible modes of motion were determined.
Źródło:
Inżynieria i Aparatura Chemiczna; 2014, 4; 318--319
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensitive detection of acetylene by second derivative spectra with tunable diode laser absorption spectroscopy
Autorzy:
Deng, H.
Sun, J.
Li, P.
Liu, Y.
Yu, B.
Li, J.
Powiązania:
https://bibliotekanauki.pl/articles/174963.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
tunable diode laser absorption spectroscopy
TDLAS
signal processing
Savitzky–Golay filter
trace gas detection
Opis:
A tunable diode laser absorption spectrometer was developed for trace acetylene gas analysis, the system performance was evaluated by combing an appropriate digital signal processing methods, i.e., Savitzky–Golay smoothing and differentiation algorithm. The calculation of the derivative spectra by this method is accompanied by simultaneous data smoothing. Based on the 2nd deriv- ative spectra detection method, the Allan variance technique indicates a C2H2 detection limit of 1.7ppm for 1-s averaging time, and a minimum noise level of 62ppb (parts per billion), at the optimum integration time of ~60s. The calculated 2nd derivative spectra with better resolution, lower detection limits, save signal processing time, and improve the ability to distinguish unresolved spectral signals.
Źródło:
Optica Applicata; 2016, 46, 3; 353-363
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of quantum cascade lasers to trace gas detection
Autorzy:
Bielecki, Z.
Stacewicz, T.
Wojtas, J.
Mikołajczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/201703.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
absorption spectroscopy
biomarkers
sensors
gas sensors
cavity enhanced spectroscopy
photoacoustic spectroscopy
spektroskopia absorpcyjna
biomarkery
czujniki gazu
spektroskopia wzmocniona
spektroskopia fotoakustyczna
Opis:
The potential of Quantum Cascade Laser technology has been recently harnessed in industry, medicine and military to create a range of original infrared gas sensors. These sensors have opened up many new applications due to compact size, excellent sensitivity, robust construction and low power requirements. They rely on infrared absorption spectroscopy to determine identity and quantity of gases. The measurement of these gases has relied on different technologies including multi-pass spectroscopy, photoacoustic spectroscopy, cavity ring down spectroscopy, and their various modifications. In this review paper some technologies are described in terms of its advantages/disadvantages in many application. The results of own works about methane, ammonia, nitric oxide, nitrous oxide, and carbonyl sulfide detection are presented as well.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 2; 515-525
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of liquid-gas flow in pipeline using gamma-ray absorption technique and advanced signal processing
Autorzy:
Hanus, Robert
Zych, Marcin
Mosorov, Volodymyr
Golijanek-Jędrzejczyk, Anna
Jaszczur, Marek
Andruszkiewicz, Artur
Powiązania:
https://bibliotekanauki.pl/articles/1848957.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
two-phase flow
void fraction
gamma-ray absorption
flow regime identification
artificial neural network
Opis:
Liquid-gas flows in pipelines appear in many industrial processes, e.g. in the nuclear, mining, and oil industry. The gamma-absorption technique is one of the methods that can be successfully applied to study such flows. This paper presents the use of the gamma-absorption method to determine the water-air flow parameters in a horizontal pipeline. Three flow types were studied in this work: plug, transitional plug-bubble, and bubble one. In the research, a radiometric set consisting of two Am-241 sources and two NaI(TI) scintillation detectors have been applied. Based on the analysis of the signals from both scintillation detectors, the gas phase velocity was calculated using the cross-correlation method (CCM). The signal from one detector was used to determine the void fraction and to recognise the flow regime. In the latter case, a Multi-Layer Perceptron-type artificial neural network (ANN) was applied. To reduce the number of signal features, the principal component analysis (PCA) was used. The expanded uncertainties of gas velocity and void fraction obtained for the flow types studied in this paper did not exceed 4.3% and 7.4% respectively. All three types of analyzed flows were recognised with 100% accuracy. Results of the experiments confirm the usefulness of the gamma-ray absorption method in combination with radiometric signal analysis by CCM and ANN with PCA for comprehensive analysis of liquid-gas flow in the pipeline.
Źródło:
Metrology and Measurement Systems; 2021, 28, 1; 145-159
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spin Resonance Absorption in a 2D Electron Gas
Autorzy:
Ungier, W.
Jantsch, W.
Wilamowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/2047694.pdf
Data publikacji:
2007-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
85.75.-d
73.63.Hs
75.75.+a
76.30.-v
Opis:
We analyze the power absorption at electron spin resonance excited by the Bychkov-Rashba spin-orbit field in a 2D electron gas. We show that, as long as the absorbed power is dissipated by the usual spin lattice relaxation mechanisms, the resonance line shape is expected to be of pure absorption type, i.e., it can be described by the imaginary part of the dynamic magnetic susceptibility. Therefore, the Dysonian line shape observed in ESR of 2D electron gas cannot result from this type of the resonance signal.
Źródło:
Acta Physica Polonica A; 2007, 112, 2; 345-350
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie rozkładu współczynnika absorpcji właściwej w śródmiąższowej hipertermii mikrofalowej
Evaluation of the specific absorption rate distribution in interstitial microwave hyperthermia
Autorzy:
Gas, P.
Powiązania:
https://bibliotekanauki.pl/articles/159485.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
śródmiąższowa hipertermia mikrofalowa
współczynnik absorpcji właściwej (SAR)
antena współosiowa ze szczeliną powietrzną
biologiczne równanie ciepła
interstitial microwave hyperthermia
specific absorption rate (SAR)
coaxial-slot antenna
bioheat equation
Opis:
Śródmiąższowa hipertermia mikrofalowa jest inwazyjną metodą leczenia, w której grzanie elektromagnetyczne jest wytwarzane przez różnego rodzaju aplikatory mikrofalowe umieszczone wewnątrz chorych tkanek. Dobry przykład może stanowić współosiowa antena ze szczeliną powietrzną przedstawiona w niniejszej pracy. Opisany 2D model matematyczny stanowi połączenie elektromagnetycznego równania falowego dla przypadku fali TM oraz biologicznego równania ciepła w stanie ustalonym. Wykorzystując metodę elementów skończonych, wyznaczono rozkłady mocy mikrofalowej oraz współczynnika absorpcji właściwej wewnątrz tkanki ludzkiej. Wyniki symulacji zostały sporządzone dla różnych wartości mocy wejściowej anteny oraz różnych tkanek.
Interstitial microwave hyperthermia is an invasive kind of treatment in which electromagnetic heating is produced by various types of the applicators located in the human pathological tissues. A good example may be a coaxial-slot antenna presented in this paper. The described 2D mathematical model consists of a coupling of the electromagnetic wave equation for TM wave case and the bioheat equation under steady-state condition. Using the finite element method, the microwave power deposition and the specific absorption rate (SAR) distributions in the human tissue are calculated. Moreover, the simulation results have been made for different values of the microwave antenna’s total input power and various tissues.
Źródło:
Prace Instytutu Elektrotechniki; 2013, 261; 15-26
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Purification of Synthetic Gas from Fine Coal Waste Gasification as a Clean Fuel
Autorzy:
Faizal, Muhammad
Said, Muhammad
Nurisman, Enggal
Aprianti, Nabila
Powiązania:
https://bibliotekanauki.pl/articles/1838398.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
absorption
CO2 capture
Ca(OH)2
fine coal
hydration
Opis:
The presence of CO2 in the syngas is attracting more attention in terms of reducing the greenhouse gas emissions in its utilisation. The aim of this study was to purify syngas from the CO2 content of fine coal gasification. Fine coal is gasified with and without absorption using CaO, which is hydrated to Ca(OH) 2 in the modified updraft gasifier at 450–700 °C. Apart from investigating the CO2 absorption process, the gasification process also evaluates the influence of temperature in terms of its synergy with Ca(OH) 2. The best conditions for the gasification process are achieved at 700 °C. The content of CO2 was proven to be well absorbed, which is characterised by a decrease in the CO2 content and an increase in H2 in syngas. After the absorption process, the H2 content obtained increased from 42.6 mole% to 48.8 mole% of H2 at 700°C. The H2 ratio also increased after absorption to 2.57 from the previous value of 2.23. The highest absorption efficiency of CO2 by Ca(OH) 2 occurred at 700°C at 50.63%. With an increase in temperature in the gasification process with absorption, the CO2 content decreased dramatically from 16.9 mole% to 3.9%. Ca(OH) 2 has good absorption power at CO2 at high temperatures.
Źródło:
Journal of Ecological Engineering; 2021, 22, 5; 114-120
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ natężenia przepływu gazu i cieczy na sprawność absorpcji CO2 w 30% roztworze monoetanoloaminy
Influence of gas and liquid flow on carbon dioxide absorption efficiency in 30% monoethanoloamine solution
Autorzy:
Krótki, A.
Śpiewak, D.
Więcław-Solny, L.
Wilk, A.
Tatarczuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/2072057.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
absorpcja CO2
CCS
MEA
CO2 absorption
carbon capture
Opis:
Przedstawiono badania wpływu obciążenia kolumny absorpcyjnej gazem i cieczą na efektywność i energochłonność procesu absorpcji CO2 w 30% roztworze monoetanoloaminy. Instalacja laboratoryjna pracowała w sposób ciągły w układzie absorpcja-desorpcja. Badano strumień powietrza o zawartości 12+14% obj. CO2. Strumień gazu zmieniano w zakresie 3+6 mn3/h, a strumień cieczy absorbującej w zakresie 20+60 dm3/h. Moc grzałki kolumny desorpcyjnej zmieniano w zakresie 1500+3000 W. Określono sprawność usuwania CO2 z gazu oraz zapotrzebowanie cieplne procesu.
Influence of gas and liquid flow on carbon dioxide absorption efficiency in 30% monoethanoloamine solution was presented in the paper. Research was carried out in a small laboratory installation working in a continuous mode. The study involved 3+6 m3n/h gas stream flow containing 12+14% carbon dioxide by volume in air and 20+60 dm3/h absorbent flow. A stripping column was heated by the electric heater with controlled power input between 1500 to 3000 W. The research allowed one to determine the CO2 removal efficiency and process heat demand per kg of CO2 removed.
Źródło:
Inżynieria i Aparatura Chemiczna; 2014, 1; 23--26
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on seawater scrubbing for SO2 removal from ships power plant exhaust gas
Autorzy:
Ma, Yiping
Xu, Leping
Su, Penghao
Feng, Daolun
Yang, Kailiang
Powiązania:
https://bibliotekanauki.pl/articles/207540.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sulfur dioxide
absorption
seawater
dwutlenek siarki
adsorpcja
woda morska
Opis:
The mechanism of SO2 absorption in seawater is investigated, and the experiment was carried out accordingly. Emphasis is on applications of seawater scrubbing of ship’s power plant exhaust gas containing SO2. The formulated model is used to predict the influence of various parameters on both pH of tailwater and seawater desulfurization capability, e.g., the partial pressure of SO2, the partial pressure of CO2, tailwater temperature, pH and alkalinity of seawater. Experiment results indicated that the seawater desulfurization capacity increases with both increasing partial pressure of SO2, pH and alkalinity and decreasing partial pressure of CO2 and temperature. The study shows the desulfurization capacity of seawater with 3.5% salinity is approximately twice that of freshwater. Different scenarios in which the required absorbent supply rate for a given SO2 removal efficiency are studied. It is observed a 97% removal efficiency, corresponding to meeting the SOx limits in the SOx emission control areas (SECA) while operating on a heavy fuel oil containing sulfur 3.5 wt. %, requires a minimum water supply rate of 0.0407–0.0683 m3/kWh, depending mainly on the water composition in terms of alkalinity and salinity. Such data are important in assessing the operation cost of the water scrubbing system.
Źródło:
Environment Protection Engineering; 2020, 46, 1; 31-47
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of air-bottoming cycle as a heat source for the carbon dioxide capture installation of a coal-fired power unit
Autorzy:
Chmielniak, T.
Lepszy, S.
Czaja, D.
Powiązania:
https://bibliotekanauki.pl/articles/240691.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
absorpcja chemiczna
cykl powietrza
system gazowo-powietrzny
turbina gazowa
air bottoming cycle
CCS
chemical absorption
gas-air systems
gas turbine
Opis:
The installations of CO2 capture from flue gases using chemical absorption require a supply of large amounts of heat into the system. The most common heating medium is steam extracted from the cycle, which results in a decrease in the power unit efficiency. The use of heat needed for the desorption process from another source could be an option for this configuration. The paper presents an application of gas-air systems for the generation of extra amounts of energy and heat. Gas-air systems, referred to as the air bottoming cycle (ABC), are composed of a gas turbine powered by natural gas, air compressor and air turbine coupled to the system by means of a heat exchanger. Example configurations of gas-air systems are presented. The efficiency and power values, as well as heat fluxes of the systems under consideration are determined. For comparison purposes, the results of modelling a system consisting of a gas turbine and a regenerative exchanger are presented.
Źródło:
Archives of Thermodynamics; 2011, 32, 3; 89-101
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of Gaseous Compounds with Different Techniques
Autorzy:
Mikołajczyk, J.
Bielecki, Z.
Stacewicz, T.
Smulko, J.
Wojtas, J.
Szabra, D.
Lentka, Ł.
Prokopiuk, A.
Magryta, P.
Powiązania:
https://bibliotekanauki.pl/articles/220919.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas sensors
laser absorption spectroscopy
CEAS
MUPASS
breath analyses
medical screening
Opis:
Sensing technology has been developed for detection of gases in some environmental, industrial, medical, and scientific applications. The main tasks of these works is to enhance performance of gas sensors taking into account their different applicability and scenarios of operation. This paper presents the descriptions, comparison and recent progress in some existing gas sensing technologies. Detailed introduction to optical sensing methods is presented. In a general way, other kinds of various sensors, such as catalytic, thermal conductivity, electrochemical, semiconductor and surface acoustic wave ones, are also presented. Furthermore, this paper focuses on performance of the optical method in detecting biomarkers in the exhaled air. There are discussed some examination results of the constructed devices. The devices operated on the basis of enhanced cavity and wavelength modulation spectroscopies. The experimental data used for analyzing applicability of these different sensing technologies in medical screening. Several suggestions related to future development are also discussed.
Źródło:
Metrology and Measurement Systems; 2016, 23, 2; 205-224
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozdział mieszanin gazowych przy wykorzystaniu ciekłych membran na podłożu ceramicznym impregnowanym cieczą jonową
Gas mixture separation on ceramic membranes impregnated with ionic liquid
Autorzy:
Rotkegel, Adam
Ziobrowski, Zenon
Powiązania:
https://bibliotekanauki.pl/articles/306026.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Instytut Inżynierii Chemicznej PAN
Tematy:
absorpcja
ditlenek węgla
ciecze jonowe
absorption
carbon dioxide
ionic liquids
Opis:
W pracy przedstawiono wyniki badań separacji ditlenku węgla i azotu na ceramicznych membranach ciekłych impregnowanych cieczą jonową [Emim][Ac] ] (octan 1-etylo-3-metyloimidazolowy). Badania przeprowadzono dla membrany ceramicznej firmy Pervatech BV w temperaturach 20-60°C dla ciśnień 1- 7 bar. Ciecz jonową nanoszono metodą pokrywania oraz zanurzania. Stwierdzono, że otrzymane membrany SILMs charakteryzują się niewielkimi strumieniami masowymi oraz dużymi wartościami selektywności.
The experimental results of carbon dioxide and nitrogen separation on ceramic membranes impregnated with ionic liquid [Emim][Ac] (1-ethyl-3-methylimidazolium acetate) are presented. Ceramic membranes made by Pervatech BV were investigated in 20-60°C and in the pressure range 1-7 bar. The ionic liquid was introduced into ceramic support by coating and soaking. It was found, that prepared SILMs are characterized by small mass fluxes and high selectivities.
Źródło:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk; 2019, 23; 55-67
1509-0760
Pojawia się w:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Straty ciśnienia fazy gazowej i skuteczność jej odsiarczania w kolumnie absorpcyjnej z wbudowaną półką sitowo-komórkową
LOSS OF PHASE GAS PRESSURE AND ITS DESULPHURIZATION EFFECTIVENESS IN ABSORPTION COLUMN WITH BUILT-IN SIEVE-CELL SHELF
Autorzy:
GŁOMBA, Michał
MAZUREK, Jerzy
Powiązania:
https://bibliotekanauki.pl/chapters/1965649.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Opis:
W pracy przedstawiono nową konstrukcję sperforowanej półki, którą nazwano półką sitowokomórkową. Uzasadniono motywację do nadania jej takiej nazwy. Półkę tę wykonano warsztatowo, a następnie po wbudowaniu jej do wnętrza pionowego absorbera natryskowego, poddano ją badaniom pod względem strat ciśnienia fazy gazowej i skuteczności odsiarczania tej fazy w pionowym absorberze natryskowym. Wewnątrz absorbera zainstalowano 4 poziomy zraszania, a ciecz rozpylano 4 rozpylaczami strumieniowo-wirowymi. Uzyskane wyniki badań poddano analizie, która doprowadziła do opracowania 2 równań korelacyjnych. Jedno z nich opisuje straty ciśnienia fazy gazowej w funkcji zadanych podczas badań parametrów pracy absorbera z półką sitowo-komórkową, a drugie równanie przedstawia zależność skuteczności odsiarczania fazy gazowej w absorberze natryskowym z tą półką.
The paper presents a new design of the perforated shelf, which was called sieve-cell shelf. Justified motivation for such a name was given. This shelf was made in a workshop and then embedded into the inside of the vertical spray absorber, it was further tested for the pressure loss of a gas phase and the desulphurization efficiency of a gas phase in the vertical spray absorber. Four levels of spray were installed inside of the absorber and a liquid was sprayed by four stream-vortex sprayers. The obtained results were analyzed, which led to the development of two correlation equations. First one describes the pressure loss of a gas phase as a function of the operating parameters preset during research of the absorber with sieve-cell shelf, and the second equation shows the dependence of the desulphurization efficiency of a gas phase in the spray absorber with sieve-cell shelf.
Źródło:
Powietrze atmosferyczne. Jakość – zagrożenia – ochrona; 106-119
9788374939423
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies