Tytuł:
Analysis of Frequency Response measurement results with end-to-end/interwinding test setup correlation
Autorzy:
Banaszak, S.
Szoka, W.
Powiązania:
https://bibliotekanauki.pl/articles/141647.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Frequency Response Analysis
transformer
winding
deformation
test setup
Opis:
The paper presents the idea of a Cross Test Comparison (CTC) method for the analysis of Frequency Response measurement results. FRA is used to detect deformations or electric faults in transformer windings. At the current stage of FRA method development, it is possible to perform repetitive measurements, however there are still problems with interpretation of test results. Authors of this paper found that analysis of results coming from two test setups (end-to-end and interwinding capacitive), which is done simultaneously is a more sensitive tool to detect some faults, and in addition it binds the influence of both voltage sides of a transformer in a single test result. The paper contains results obtained from laboratory tests, where controlled deformations were introduced into windings and also measurements from industry. The CTC method combines both the end-to-end and capacitive interwinding measurements into a single dataset, by subtracting the amplitudes at the corresponding frequencies. The resulting combined dataset is more sensitive in identifying deviations from baseline measurements.
Źródło:
Archives of Electrical Engineering; 2018, 67, 1; 51-64
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part I
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114413.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 322-324
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part II
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114230.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 325-328
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Poprawa właściwości metrologicznych systemu przeznaczonego do pomiaru położenia z wykorzystaniem pola magnetycznego małej częstotliwości
Improvement Of Metrological Properties Of The System For Measurement Of 3D Position Using Low Frequency Magnetic Field
Autorzy:
Baszyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/152850.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektronika medyczna
pomiar położenia z wykorzystaniem pola magnetycznego
medical electronics
position measurement systems
Opis:
W artykule opisano modyfikacje wprowadzone do istniejącego systemu służącego do pomiaru położenia, wykorzystującego pole magnetyczne małej częstotliwości. Gruntowne zmiany objęły wszystkie elementy systemu, przede wszystkim zmieniony został algorytm wyznaczania położenia, przeprojektowano całkowicie tor analizy sygnału oraz zespół generatorów pola magnetycznego. Zastosowane modyfikacje zapewniły znaczną poprawę parametrów metrologicznych systemu, w szczególności zaś zwiększenie szybkości pracy, poprawę dokładności oraz poszerzenie zasięgu pomiarowego. Zredukowane zostały także wymiary fizyczne systemu oraz jego energochłonność.
This article describes modifications introduced to the principles and the implementation of a 3D imaging system using low frequency magnetic field. Modifications to the imaging algorithm, the construction of magnetic field generators and the whole signal-processing path have been applied. These modifications entail significant improvements to several metrological properties; particularly increased accuracy, speed and range. The dimensions and power consumption of the imaging system are also reduced.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 560-563
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System pomiarowy sygnałów HPEM w badaniach zabezpieczeń systemów teleinformatycznych
A measurement system of HPEM signals in investigations of teleinformatic system security
Autorzy:
Biaduń, M.
Berczyński, R.
Kuchta, M.
Powiązania:
https://bibliotekanauki.pl/articles/156906.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
HPEM
sygnał szybkozmienny
przetwornik A/C
high-frequency signal
converter A/C
Opis:
W referacie przedstawiono system akwizycji danych pomiarowych z bardzo szybkim przetwornikiem analogowo-cyfrowym AD9484 Analog Devices. Stanowi on końcowy stopień systemu pomiarowego do identyfikacji i pomiarów wybranych parametrów impulsów elektromagnetycznych o bardzo dużej mocy [4]. Układ pomiarowy pozwala na przeprowadzenie badań związanych z bezpieczeństwem systemów teleinformatycznych narażonych na sygnały HPEM (ang. High Power Electromagnetics), czyli ekstremalnie wysokomocowych impulsów promieniowania elektromagnetycznego. Technologia opiera się na wykorzystaniu pola elektromagnetycznego o bardzo dużym natężeniu, powodując uszkodzenia lub zniszczenia urządzeń elektronicznych. Impulsy elektromagnetyczne HPEM charakteryzują się szczególnymi parametrami: wysoką mocą emitowanych impulsów, bardzo krótkim czasem trwania impulsów oraz prędkością propagacji równą prędkości światła, które sprawiają, że broń elektromagnetyczna jest niezwykle skuteczna w działaniach wojennych czy terrorystycznych. Rejestrację i analizę sygnałów wspomaga oprogramowanie VisualAnalog, zawierające bogaty zestaw do symulacji, przetwarzania danych oraz przeprowadzania licznych testów na zgromadzonych danych pomiarowych. Przedstawiono przykładowe charakterystyki amplitudowoczasowe oraz amplitudowo-częstotliwościowe sygnałów HPEM.
The paper presents a data acquisition system with a very fast analogtodigital converter Analog Devices AD9484. It is the final stage of a measurement system for identification and measurement of selected parameters of electromagnetic pulses of very high power [4]. The measurement system allows for tests connected with the security of ICT systems exposed to HPEM (High Power Electromagnetics) signals, which are extremely high power pulses of electromagnetic radiation. The technology is based on the use of the electromagnetic field of very high intensity, causing damage or destroying electronic devices. HPEM electromagnetic pulses are characterized by specific parameters: a high power of the emitted pulses, a very short duration of pulses and the propagation velocity equal to the speed of light which makes electromagnetic weapon extremely effective in warfare or terrorism. Recording and analyzing signals supports the VisualAnalog software, including a rich set of simulation, data processing, and performing a big number of tests on the collected measurement data. Examples of the amplitude-time and amplitude-frequency characteristics of HPEM signals are presented in Section 3 of the paper.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 9, 9; 753-755
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja metodyki pomiaru wieloczęstotliwościowego pola elektromagnetycznego stacji bazowych telefonii komórkowej
Optimization of measurement methods for a multi-frequency electromagnetic field from mobile phone base station using broadband EMF meter
Autorzy:
Bieńkowski, Paweł
Cała, Paweł
Zubrzak, Bartłomiej
Powiązania:
https://bibliotekanauki.pl/articles/2164387.pdf
Data publikacji:
2015-11-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
metrologia pola elektromagnetycznego
pasmo E
ekspozycja środowiska
bezpieczeństwo pracy w polach elektromagnetycznych
niepewność pomiaru
stacje bazowe telefonii komórkowej
metrology of electromagnetic fields
E band
exposure environment
work safety in electromagnetic fields
measurement uncertainty
cellular base stations
Opis:
Wstęp W artykule przedstawiono charakterystykę źródła pola elektromagnetycznego (PEM), jakim jest stacja bazowa (base station – BS) telefonii komórkowej. Opisano najczęściej spotykane konfiguracje systemowe wraz z ich budową i omówiono specyfikę promieniowanego PEM w zależności od sposobu dostępu do usług telekomunikacyjnych i parametrów transmisji radiowej. Poświęcono także uwagę antenom, jakie są montowane na masztach BS i podano ich typowe parametry. Materiał i metody Analizie poddano wpływ poszczególnych składowych pola wieloczęstotliwościowego, jakie najczęściej jest spotykane w otoczeniu BS, na wypadkowe natężenie PEM mierzone za pomocą popularnych mierników szerokopasmowych. Przedstawiono przykładowe charakterystyki najczęściej spotykanych sond PEM i 2 scenariusze pomiarowe: w jednym źródłem PEM była wielosystemowa stacja bazowa z mikrofalowymi liniami radiowymi, w drugim – stacja bez linii radiowych. Wyniki Przedstawiono metodę pomiaru wieloczęstotliwościowego PEM za pomocą 2 sond szerokopasmowych, która pozwala na znaczne zminimalizowanie niepewności pomiaru. Wzory i przekształcenia, za których pomocą można obliczyć rzeczywiste natężenie PEM w otoczeniu źródeł wieloczęstotliwościowych, zweryfikowano w warunkach laboratoryjnych na specjalnym stanowisku wzorcowym wieloczęstotliwościowego PEM oraz w warunkach rzeczywistych – podczas wykonywania pomiaru istniejącej stacji bazowej z mikrofalowymi liniami radiowymi. Wnioski Metodykę pomiaru natężenia PEM w otoczeniu stacji bazowych z mikrofalowymi liniami radiowymi zwalidowano w warunkach zarówno laboratoryjnych, jak i rzeczywistych, co pozwoliło w znacznym stopniu ograniczyć niepewność pomiaru tak specyficznego źródła PEM. Jest to najbardziej optymalne podejście do przeprowadzenia oceny ekspozycji na PEM w otoczeniu BS. Alternatywną metodą oceny jest metoda ostrożności (o znacznie większej niepewności pomiaru) i metoda wyłączenia jednego ze źródeł (o bardziej skomplikowanej procedurze pomiarowej). Med. Pr. 2015;66(5):701–712
Background This paper presents the characteristics of the mobile phone base station (BS) as an electromagnetic field (EMF) source. The most common system configurations with their construction are described. The parameters of radiated EMF in the context of the access to methods and other parameters of the radio transmission are discussed. Attention was also paid to antennas that are used in this technology. Material and Methods The influence of individual components of a multi-frequency EMF, most commonly found in the BS surroundings, on the resultant EMF strength value indicated by popular broadband EMF meters was analyzed. The examples of metrological characteristics of the most common EMF probes and 2 measurement scenarios of the multisystem base station, with and without microwave relays, are shown. Results The presented method for measuring the multi-frequency EMF using 2 broadband probes allows for the significant minimization of measurement uncertainty. Equations and formulas that can be used to calculate the actual EMF intensity from multi-frequency sources are shown. They have been verified in the laboratory conditions on a specific standard setup as well as in real conditions in a survey of the existing base station with microwave relays. Conclusions Presented measurement methodology of multi-frequency EMF from BS with microwave relays, validated both in laboratory and real conditions. It has been proven that the described measurement methodology is the optimal approach to the evaluation of EMF exposure in BS surrounding. Alternative approaches with much greater uncertainty (precaution method) or more complex measuring procedure (sources exclusion method) are also presented. Med Pr 2015;66(5):701–712
Źródło:
Medycyna Pracy; 2015, 66, 5; 701-712
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dopasowanie wartości parametrów pomiaru cyfrowego nierówności profilu do charakteru powierzchni przedmiotu
Matching the parameter values of digital measurement to workpiece surface profile irregularities
Autorzy:
Boryczko, K.
Powiązania:
https://bibliotekanauki.pl/articles/157754.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary powierzchni
warunki pomiaru
struktura geometryczna powierzchni
analiza częstotliwościowa
surface measurement
measurement conditions
surface geometrical structure
frequency analysis
Opis:
W pracy przedstawiono dopasowanie parametrów pomiaru do rodzaju powierzchni i analizy częstotliwościowej nierówności powierzchni toczonych dla celów rozpoznawania ich głównych składowych. Podano zależności parametrów cyfrowych pomiaru nierówności warunkujące ich częstotliwościowe zakresy rozpatrywania. W podsumowaniu podano zakres analizy częstotliwościowej nierówności powierzchni z dolno- i górnopasmowymi rodzajami ograniczeń oraz wskazówki doboru parametrów pomiaru dla otrzymania właściwego zakresu analizy nierówności powierzchni.
Conditions of measurement, the analogue-to-digital conversion and the frequency analysis of turned surface irregularities for the purpose of its main components identification are presented in the paper. A range of digital parameters have been defined along with their relation to each other, specifying the ranges in which they should be used in order to measure surface irregularity (Tab.1). The parameter values obtained by digital measurement vary within specific ranges, and hence determine the surface irregularities [1, 2, 3]. For this measurement, it is essential to select proper sampling interval hp and the number of measured data N for the value and character of the irregularities measured [4, 5] (Fig.2). The method of frequency analysis for periodical surface irregularities, with the application of power spectral density and the use of fast Fourier transformation (FFT), has been presented in papers [6, 7]. The required conditions for the method presented in this paper, and the possible matching of frequency to wide-band surface irregularities are presented. The maximum frequency of the given irregularity is determined by the value of the sampling interval. Due to this fact, the sampling interval values should be selected in a way to include the low-frequency range of dominant components of the surface irregularity [8] (Fig.3). To summarise, the resulting frequency range of surface irregularities, with high and low-frequency limitations, has been given. Furthermore, the indication of the suitable selection range to capture significant surface irregularities has been included.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 9, 9; 1063-1066
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic response of the Stuttgart TV Tower measured by classical instruments and GPS technology
Pomiary odpowiedzi dynamicznej wieży telewizyjnej w Stuttgarcie za pomocą klasycznych przyrządów pomiarowych i technologią GPS
Autorzy:
Breuer, Peter
Chmielewski, Tadeusz
Górski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1853630.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wieża telewizyjna
Stuttgart
pomiar GPS
odpowiedź dynamiczna
odpowiedź spowodowana wiatrem
częstotliwości drgań własnych
liczba tłumienia drgań
television tower
GPS measurement
wind-induced response
dynamic response
natural frequency
damping ratio
Opis:
This paper compares the measurement results of dynamic characteristics, including natural frequencies, damping ratio, and wind-induced responses of the Stuttgart TV Tower (TV Tower), obtained by Lenk in 1959 using classical instruments with those obtained by the authors a few decades later using Global Positioning System (GPS). The objective of this paper was to monitor the response of the TV Tower under wind loading, which is an important tool for the validation of its design, construction, and structural health. During the authors’ GPS measurements, weak and moderate wind speeds occurred most of the time. Only in 2007, the stronger wind observed (90 < V < 100 km/h) at the head of the TV Tower (H=157 m), which caused displacements in the decimetre range. Further measurements in 2011 were carried out, using additional GPS receivers with a higher data rate. The results achieved by the GPS prove that the cross-wind response was larger than the along-wind component for all ranges of wind speed, which occurred during the measurement periods, i.e. from 2002 to 2015. The authors of this paper extended Lenk’s results, by the static and along-wind components, confirmed the first natural frequency, and damping ratio, evaluated by the Random Decrement technique. Mounting a GPS receiver, on the steel antenna mast tip, enabled detection of the second natural frequency fs2 = 0.800 Hz, which is the frequency of the mode shape of the TV Tower steel antenna mast. Lenk did not measure this frequency.
Wieża telewizyjna w Stuttgarcie została oddana do użytkowania w dniu 5 lutego 1956 roku. Konstrukcja wieży składa się z dwóch części: (a) trzonu żelbetowego z głowicą o wysokości 161 m i (b) stalowego masztu antenowego o wysokości 56 m. Całkowita wysokość wieży to 217 m. Średnica zewnętrzna trzonu żelbetonowego wynosi 10,8 m u podstawy trzonu i 5,04 m w górnej części trzonu (poniżej głowicy trzonu). Grubość ściany trzonu zmienia się od 60 cm do 19 cm. W latach 1953-1954 Leonhard zaproponował koncepcję i projekt wieży telewizyjnej. Biuro projektowe Pieckert zaprojektowało system konstrukcyjny. Koncepcję wieży telewizyjnej, jej układ konstrukcyjny, wszystkie założenia do obliczeń statycznych, oszacowanie nakładów finansowych i pierwsze pomiary osiadań fundamentów podane zostały w jednej z prac Leonhardta. W tej pracy zasugerowano także potrzebę pomiaru odpowiedzi wieży telewizyjnej na działanie wiatru. Jako pierwszy dokonał tego Lenk w 1959 roku. W latach 1977 i 1995 stwierdzono pionowe pęknięcia w żelbetowym trzonie wieży, które następnie zostały naprawione. Przyczyny tych pęknięć wyjaśniono jako konsekwencje promieniowania słonecznego i dobowych zmian temperatury powietrza działających na trzon wieży telewizyjnej, wywołujących deformacje płaszcza trzonu. Naprężenia termiczne spowodowały zmienną w czasie „owalizację” trzonu wieży, która z biegiem lat doprowadziła do zmęczenia materiału, czego skutkiem były wyraźnie widoczne podłużne pęknięcia po przeciwnych stronach trzonu wieży telewizyjnej. Autorom niniejszego artykułu nie są znane wcześniejsze pomiary charakterystyk dynamicznych wieży telewizyjnej związane z naprawą powstałych pęknięć. W związku z tym, w 1999 roku autorzy przeprowadzili pierwszą serię pomiarów przemieszczeń wierzchołka wieży telewizyjnej z zastosowaniem techniki satelitarnej GPS. Metodologia pomiarów była podobna do metodologii stosowanej przez innych badaczy. Na tej podstawie autorzy potwierdzili możliwość zastosowania systemu GPS do monitorowania przemieszczeń statycznych, quasi-statycznych i dynamicznych oraz do określania podstawowych charakterystyk dynamicznych (częstotliwości drgań własnych i współczynników tłumienia drgań) istniejących dużych konstrukcji w skali naturalnej. Autorzy cyklicznie monitorowali przedmiotową wieżę telewizyjną do roku 2015. Jednak pomimo podjętego wysiłku w celu zebrania dodatkowych danych pomiarowych, niestety w 2013 i 2015 r. nie było możliwości pomiaru przemieszczeń wieży telewizyjnej pod wpływem silnego wiatru. Niemniej jednak autorzy dokonali analizy danych pomiarowych zgromadzonych w latach 2002, 2005, 2006, 2007, 2008 i 2011, które obejmowały pomiary w zakresie prędkości wiatru od małej do dużej. W dniach 18-19 stycznia 2007 r. w pobliżu wieży zarejestrowano porywy wiatru o prędkości 26 m/s, co spowodowało jej przemieszczenia w zakresie decymetrów.
Źródło:
Archives of Civil Engineering; 2021, 67, 1; 7-38
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Extremely Low Frequency Magnetic Field Emission from Laptop Computers
Autorzy:
Brodić, D.
Powiązania:
https://bibliotekanauki.pl/articles/221562.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
classification
ELF
EMF
laptop
measurement
Opis:
This study addresses the problem of magnetic field emission produced by the laptop computers. Although, the magnetic field is spread over the entire frequency spectrum, the most dangerous part of it to the laptop users is the frequency range from 50 to 500 Hz, commonly called the extremely low frequency magnetic field. In this frequency region the magnetic field is characterized by high peak values. To examine the influence of laptop’s magnetic field emission in the office, a specific experiment is proposed. It includes the measurement of the magnetic field at six laptop’s positions, which are in close contact to its user. The results obtained from ten different laptop computers show the extremely high emission at some positions, which are dependent on the power dissipation or bad ergonomics. Eventually, the experiment extracts these dangerous positions of magnetic field emission and suggests possible solutions.
Źródło:
Metrology and Measurement Systems; 2016, 23, 1; 143-154
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simple Wide Frequency Range Impedance Meter Based on AD5933 Integrated Circuit
Autorzy:
Chabowski, K.
Piasecki, T.
Dzierka, A.
Nitsch, K.
Powiązania:
https://bibliotekanauki.pl/articles/221804.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
impedance
converter
AD5933
system-on-a-chip
measurement
Opis:
As it contains elements of complete digital impedance meter, the AD5933 integrated circuit is an interesting solution for impedance measurements. However, its use for measurements in a wide range of impedances and frequencies requires an additional digital and analogue circuitry. This paper presents the design and performance of a simple impedance meter based on the AD5933 IC. Apart from the AD5933 IC it consists of a clock generator with a programmable prescaler, a novel DC offset canceller for the excitation signal based on peak detectors and a current to voltage converter with switchable conversion ratios. The authors proposed a simple method for choosing the measurement frequency to minimalize errors resulting from the spectral leakage and distortion caused by a lack of an anti-aliasing filter in the DDS generator. Additionally, a novel method for the AD5933 IC calibration was proposed. It consists in a mathematical compensation of the systematic error occurring in the argument of the value returned from the AD5933 IC as a result. The performance of the whole system is demonstrated in an exemplary measurement.
Źródło:
Metrology and Measurement Systems; 2015, 22, 1; 13-24
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary charakterystyk szumowych jako narzędzie diagnostyczne detektorów UV
Noise characteristic measurement as a tool for UV detectors diagnostic
Autorzy:
Ćwirko, J.
Ćwirko, R.
Powiązania:
https://bibliotekanauki.pl/articles/327504.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
detektor UV
GaN
AlGaN
szumy niskoczęstotliwościowe
UV detectors
low-frequency noise
Opis:
W artykule przedstawiono zastosowanie analizy niskoczęstotliwościowych charakterystyk szumowych do diagnostyki detektorów UV. Ze względu na zakres widmowy detektory UV są wykonywane z materiałów o szerokiej przerwie zabronionej, głównie z GaN, AlN, SiC. Detektory UV są głównie stosowane w automatyce przemysłowej, robotyce, medycynie, systemach ochrony środowiska i technologiach militarnych. Charakterystyki szumowe detektorów były mierzone w szerokim zakresie temperatury (80 K - 350 K) oraz w funkcji napięcia polaryzacji. Analiza charakterystyk szumowych umożliwia wybranie optymalnego punktu pracy detektora ze względu na stosunek sygnału użytecznego do szumu oraz pozwala prognozować jego niezawodność.
The work is aimed on analyze the low frequency noise characteristics of UV detectors. UV detectors are manufactured from wide band gap materials as GaN, AlGaN, SiC. The most important fields of UV detectors applications are industrial automation, robotics, space technology, medicine, military technology and solar ultraviolet measurements. The noise characteristics of UV detectors were measurement in wide temperature range (from 80 K to 350 K) and as function of polarization. The investigation results should be allowed to optimize the UV detection system providing maximal value of signal-to-noise ratio, selection of the optimal working point and estimate reliability of detectors UV.
Źródło:
Diagnostyka; 2006, 4(40); 199-202
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar różnicy faz sygnałów napięciowych
Phase measurements of voltage signals
Autorzy:
Czubla, A.
Stępniewski, J.
Konopka, J.
Powiązania:
https://bibliotekanauki.pl/articles/151438.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
precyzyjny pomiar fazy
metrologia czasu i częstotliwości
precise phase measurement
time and frequency metrology
Opis:
W niniejszym referacie przedstawiona została teoria i praktyka pomiaru różnicy faz sygnałów napięciowych za pomocą częstościomierza-czasomierza cyfrowego. Szczególną uwagę zwrócono na czynniki mające bezpośredni wpływ na wartość i niepewność wyniku pomiaru oraz zapro-ponowano sposób zminimalizowania ich wpływu. W efekcie uzyskano zweryfikowane i spójne wyniki pomiaru różnicy faz sygnałów napięciowych wykonanych za pomocą częstościomierza-czasomierza, w pełni wykorzystując dużą precyzję pomiaru czasu.
In this paper, we present the theory and practical aspects of phase measurements of voltage signals with usage of universal time and frequency counter. Special attention is turned to the factors which influence directly the final value and uncertainty of measurement's result. We propose a method of reducing their influence. As a result, we obtain verified and consistent results of phase measurements of voltage signals performed with a universal time and frequency counter, using to the full its high precision for time measurements.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9, 9; 81-82
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect Analysis of Loudspeaker’s Placement Angle and Direction on Frequency Response and Sound Pressure Level in TV Applications
Autorzy:
Demirel, Ibrahim
Powiązania:
https://bibliotekanauki.pl/articles/1953509.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic transducers
frequency measurement
frequency response
loudspeakers
Opis:
In a television, obtaining a good acoustic response is a challenging issue because of slim mechanical structures. The area dedicated for speaker’s placement is limited and inadequate space inside the cabinet of a TV prevents possible solutions to increase the sound performance. In addition, frame of the TV’s is getting narrower as the customers searching for the highest screen to body ratio. These designing aspects restrain optimal speaker positioning to achieve good sound performance. In this paper, an analysis related to speaker’s placement and mounting angle is proposed. A rotation setup compatible with a TV was prepared to measure different facing position of the speaker. This paper proposes the analysis of speaker’s rotation and facing direction in a flat panel television and its effects on sound pressure level together with deviation of the acoustic response. Measurement results are analyzed with an audio analyzer together with a statistics tool to achieve precise results.
Źródło:
Archives of Acoustics; 2021, 46, 1; 79-85
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar błędów częstotliwościowych obwodów wejściowych przetworników energetycznych metodą pomiaru zespolonego stosunku napięć
Measurement of the frequency errors of input circuit using a complex voltage ratio measurement
Autorzy:
Furmankiewicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/152097.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
błędy częstotliwościowe
obwody wejściowe energetycznych przyrządów pomiarowych
frequency errors
input circuit of power measurement instruments
Opis:
W artykule przedstawiono koncepcję pomiaru błędów częstotliwościowych obwodów wejściowych stosowanych elektroenergetycznych przyrządach pomiarowych. Błąd modułu i błąd fazowy wyznaczane są na podstawie pomiaru zespolonego stosunku napięć w próbkującym systemie pomiarowym. Koncepcja pomiaru została wykorzystana do wyznaczenia błędów przekładni transformatorowych obwodów wejściowych. Zaprezentowano strukturę systemu pomiarowego i przykładowe wyniki badań, które posłużyły do korekcji błędów częstotliwościowych obwodów wejściowych przy pomiarach wartości skutecznej i mocy.
The paper presents an idea of frequency errors measurement of the input circuit implemented in measurement instruments of power systems. The module and the phase errors are calculated on the basis of complex voltage ratio measurement in DAQ system (fig. 2). The idea was used to frequency errors measurement of current measuring transformers used in some power transducers (fig. 3). The results of the measurement were used to correction of the errors that are introduced by measuring transformers on power measurement accuracy with distorted signals.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 6, 6; 392-394
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczenie odchylenia względnego częstotliwości oraz niestabilności częstotliwości wzorców
Measurement of fractional frequency difference and frequency stability calculation
Autorzy:
Gadomska, A.
Górecki, M.
Powiązania:
https://bibliotekanauki.pl/articles/209179.pdf
Data publikacji:
2008
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
czas
częstotliwość
niestabilność
odchylenie Allana
time
frequency
stability
Allan deviation
Opis:
Praca prezentuje metodę pomiaru odchylenia względnego częstotliwości (o.w.cz.) oraz wyznaczania niestabilności częstotliwości (odchylenie Allana) wzorców częstotliwości za pomocą komparatora fazy i częstotliwości w połączeniu z częstościomierzem cyfrowym. Dane pomiarowe zbierane są automatycznie i przeliczane przy pomocy arkuszy kalkulacyjnych oraz specjalistycznego oprogramowania do analizy danych w dziedzinie częstotliwości Stable 32. W pracy zawarto również analizę źródeł niepewności występujących przy pomiarach częstotliwości oraz opisano sposób wyznaczania poprawki związanej z prognozą o.w.cz. wzorca odniesienia.
This paper presents a method of fractional frequency difference measurement and frequency stability (Allan deviation) calculation of frequency standards with frequency and phase comparator in connection with a frequency counter. Measurement data are collected automatically and calculated with calculation sheets or with special purpose software Stable 32 for time- and frequency-domain data analysis. This paper presents also the sources of uncertainties that occur during frequency measurement and reveals the method of reference standard accuracy prognosis calculation.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2008, 57, 2; 367-376
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies