Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fluidized boiler" wg kryterium: Wszystkie pola


Wyświetlanie 1-35 z 35
Tytuł:
Transfer function matrix model of the bubbling fluidized bed boiler
Autorzy:
Porzuczek, J.
Powiązania:
https://bibliotekanauki.pl/articles/240580.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kotła fluidalne
macierz transferu
system identyfikacji
bubbling fluidized bed boiler
system identification
transfer function matrix
Opis:
The paper presents proposal of a model of the fluidized bed boiler adapted for use in model-based controllers e.g. predictive, adaptive or internal model control (IMC). The model has been derived in the form of transfer function matrix which allows its direct implementation in the controller structure. Formulated model takes into consideration the principal cross-coupling between process variables which enables the opportunity to search for feasibility of decoupling control. The results of the identification of the dynamics of the 2 MW industrial bubbling fluidized bed boiler using the proposed model form was presented. According to the experimental data it was found that despite of introduced simplifications presented model allows the boiler behavior prediction.
Źródło:
Archives of Thermodynamics; 2011, 32, 3; 245-31
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Properties of fluid ashes and their utilizability
Właściwości i wykorzystanie popiołów lotnych
Autorzy:
Michalikova, F.
Brezani, I.
Sisol, M.
Drabova, M.
Mosej, J.
Powiązania:
https://bibliotekanauki.pl/articles/971056.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
coal
combustion
ash
fluidized boiler
węgiel
spalanie
popiół
kocioł fluidalny
Opis:
This paper presents properties of ashes from combustion of black/hard coal in fluidized bed type boilers of EVO Vojany thermal power plant. Properties of ashes depend on inorganic components in coal and combustion temperature. Method for recovery of Fe component using low intensity magnetic separation from fluid bed ash is presented.
Niniejszy referat prezentuje właściwości popiołów pochodzących ze spalania antracytu w złożach fluidalnych w elektrowni cieplnej EVO Vojany. Właściwości popiołów zależą od składników nieorganicznych w węgli oraz temperatury spalania. Zaprezentowano również metodę odzyskiwania składnika Fe przy użyciu mało intensywnej separacji magnetycznej od złoża.
Źródło:
Inżynieria Mineralna; 2013, R. 14, nr 2, 2; 99-103
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the environment on the operational safety of a fluidized bed boiler
Autorzy:
Dudek, Agata
Kobyłecki, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/88702.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
fluidized bed boiler
anchors
refractory damage
kocioł fluidalny
kotwy
uszkodzenie ogniotrwałe
Opis:
The use of fluidized bed boilers in modern power engineering is a promising solution for clean and economically acceptable combustion of various fuels, including coal, biomass and waste, for the generation of electricity. The fluidized bed boilers are nowadays technically advanced and complex combustion facilities where all individual boiler elements are subjected to withstand continuous structural and thermal loads during their operation. Intensive loading of boiler elements can be quite easily linked with boiler operational safety and is quite often one of the main reasons for emergency shutdowns followed by necessary replacements of the damaged items. In case of industrial large-scale circulating fluidized bed boilers the frequency of unplanned shutdowns is also quite often affected by the hydrodynamics of the fluidized bed and some other parameters, such as the intensity of solids circulation, temperature, solids concentration, flue gas composition and velocity, solids accumulation and deposition, as well as the corrosion or erosion of heat transfer surfaces. The present paper briefly reports the results of authors investigation focused on the morphology and structure of some chosen elements (steel anchors) sampled from one of Polish circulating fluidized bed boilers. The anchors were degraded during boiler operation and lost their mechanical durability. In order to determine the reasons of anchors’ degradation chemical composition of the elements was determined with the use of a spark spectrometer SPECTROLAB and sample morphology was investigated with JEOL JSM-6610LV scanning microscope equipped with LaB6 cathode.
Źródło:
System Safety : Human - Technical Facility - Environment; 2019, 1, 1; 678-683
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the efficiency of the unit based on circulating fluidized bed boiler integrated with three-end high-temperature membrane for air separation
Analiza efektywności układu kotła cyrkulacyjnego typu oxy z membraną wysokotemperaturową typu three-end do separacji powietrza
Autorzy:
Kotowicz, J.
Balicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/172915.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kocioł fluidalny
membrana typu three-end
separacja powietrza
fluidized boiler
three-end membrane
air separation
Opis:
W artykule analizie poddano kocioł z cyrkulacyjnym złożem fluidalnym. Do spalania węgla brunatnego w kotle użyto tlenu wytworzonego w wysokotemperaturowej membranie typu three-end. Pokazano sposób określenia powierzchni membran oraz energochłonności procesu membranowej separacji powietrza. Sprawność termiczną kotła, energochłonność membranowej separacji powietrza i powierzchnię modułu membranowego wyznaczono w funkcji odzysku tlenu w membranie. Zaproponowano wykorzystanie azotu z instalacji separacji powietrza do suszenia węgla. Dla takiego wariantu również wyznaczono charakterystyki układu. Stwierdzono, że przy wykorzystaniu azotu do suszenia sprawności termicznej kotła rośnie z 76% do 87%, przy wzroście stopnia odzysku tlenu od 0,45 do 0,9, i jest wyższa odpowiednio od 12% do 6% w porównaniu do układu bez suszenia. W zaproponowanym układzie separacji powietrza powierzchnia modułu membranowego zawiera się w przedziale 76,5-95,0 tys. m².
In this paper boiler with circulating fluidized bed was analyzed. For the combustion of lignite in the boiler oxygen produced in the three-end high-temperature membrane was used. Paper shows a method of determining the surface of the membranes and energy consumption of the air separation process. Boiler thermal efficiency, energy consumption of the process and air separation membrane module surface was determined as a function of oxygen recovery in the membrane. Nitrogen from the air separation unit was proposed to be used for drying lignite. For this variant characteristics of the system were determined. It was found that the thermal efficiency of the boiler in case where nitrogen was used for lignite drying increased from 76% to 87% with increasing value of oxygen recovery ratio from 0.45 to 0.9 and is higher, respectively, from 12% to 6% in comparison to the system without drying. In the proposed air separation unit required membrane surface is in the range 76500-95000 m².
Źródło:
Archiwum Energetyki; 2012, 42, 2; 59-71
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical models for simulation of layer hydrodynamics of a ship fluidized bed boiler
Autorzy:
Tryczak, J. R.
Zeńczak, W.
Powiązania:
https://bibliotekanauki.pl/articles/135090.pdf
Data publikacji:
2016
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
two-phase flows
fluidized bed boilers
mathematical modeling
simulation
ship
swaying motion
Opis:
Fluidized bed boilers have been widely used for many years in energetics but their application in shipbuilding has been incidental. The hydrodynamics of a fluidized bed is a complicated issue. If the swaying of a ship on a sea wave is taken into account, this issue will be further complicated. The choice of an appropriate mathematical model is important from the viewpoint of building computer models for the simulation of a fluidized bed during disruptions that result from the ship swaying on sea waves. Fluidization is a two-phase flow process, which is described by many models such as the homogeneous-slip model or heterogeneous-slide model. The most popular models that show two-phase gas-solid or fluid-solid flow are the Euler-Euler and Euler-Lagrange models. The paper presents models that describe a ship’s fluidized bed.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2016, 47 (119); 54-58
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics modeling for supercritical circulating fluidized bed boiler working in oxy-combustion technology
Autorzy:
Balicki, A.
Bartela, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/240453.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermodynamic analysis
oxy-combustion
supercritical CFB boiler
analiza termodynamiczna
oksyspalanie
nadkrytyczny kocioł CFB
Opis:
Among the technologies which allow to reduce greenhouse gas emission, mainly carbon dioxide, special attention deserves the idea of 'zero-emission' technology based on boilers working in oxy-combustion technology. In the paper the results of analyses of the influence of changing two quantities, namely oxygen share in oxidant produced in the air separation unit, and oxygen share in oxidant supplied to the furnace chamber on the selected characteristics of a steam boiler including the degree of exhaust gas recirculation, boiler efficiency and adiabatic flame temperature, was examined. Due to the possibility of the integration of boiler model with carbon dioxide capture, separation and storage installation, the subject of the analysis was also to determine composition of the flue gas at the outlet of a moisture condensation installation. Required calculations were made using a model of a supercritical circulating fluidized bed boiler working in oxy-combustion technology, which was built in a commercial software and in-house codes.
Źródło:
Archives of Thermodynamics; 2014, 35, 2; 51-63
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of a Primary Air Distribution in a Plenum Chamber of the 700 MWth Circulating Fluidized Bed Boiler
Autorzy:
Mirek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2201878.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
windbox
circulating fluidized bed boiler
fluidization
primary air
Opis:
The windbox is a compressed air chamber installed directly beneath the fluidized bed boiler grid and is designed to evenly distribute air across the entire cross-section of the air distributor. Due to the large volume of the plenum chambers, it is very difficult to experimentally determine the flow conditions within them. Therefore, the analysis of airflow in these devices is usually performed using computational fluid dynamics tools. The article presents the results of modeling primary air distribution in the plenum chamber of the 700 MWth circulating fluidized bed boiler operating in PGE GiEK S.A. Turów Power Plant Division. Based on the results of calculations performed using the ANSYS Fluent software, the basic problems of the design windbox geometry were identified and a method for improving the uniformity of the gas flow under the grid was proposed. As can be seen from the results obtained, the design geometry of the windbox does not provide the required uniformity of air distribution under the grid.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 5; 86--99
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of the fluidized bed boiler for the disposal of the multi-material packaging waste
Autorzy:
Zabagło, J.
Baron, J.
Olek, M.
Kandefer, S.
Żukowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/778017.pdf
Data publikacji:
2010
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
odpady opakowań
unieszkodliwianie termiczne
fluidyzacja
odzysk ciepła
odzysk aluminium
packaging waste
thermal disposal
fluidization
heat recovery and aluminum recovery
Opis:
The paper presents the results of the disposal of packaging waste from two companies: Tetra Pak and Combibloc, carried out in a fluidized bed boiler of rated thermal power 0.5 MW. The material introduced into the fluidized bed boiler underwent thermal and mechanical degradation in a sand bed of the temperature between 750 and 850°C. The process proceeds auto-thermally, without the need of additional fuel. The appropriately chosen fluidization parameters caused the separation of the solid products of combustion from the deposit material. Presence of aluminum, part of it in an un-oxidized form, was confirmed in separated dust. The gaseous products of combustion contained the traces of oxides of nitrogen and sulfur, mainly originating from the remnants of food products contained in the packaging. However, the concentration of these oxides met the requirements of emission standards.
Źródło:
Polish Journal of Chemical Technology; 2010, 12, 4; 19-21
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność zapraw z udziałem popiołów lotnych z kotłów fluidalnych i konwencjonalnych na korozję kwasową
The resistance of mortars with fluidized beds boiler fly ashes and conventional fly ashes to acid corrosion
Autorzy:
Janowska-Renkas, E.
Kowalska, J.
Kaliciak, A.
Janus, G.
Powiązania:
https://bibliotekanauki.pl/articles/131481.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Komisja Inżynierii Budowlanej PAN Oddział w Katowicach
Tematy:
popioły lotne ze spalania w kotłach fluidalnych
popioły lotne z kotłów konwencjonalnych
korozja kwasowa
trwałość zapraw
fly ashes
fluidized boiler
conventional boiler
acid corrosion
durability of cement mortars
Opis:
This paper presents the results of research undertaken to determine the impact of the aggressive environment of acid corrosion on the durability of cement mortars with the participation of fluidized beds boiler fly ashes and conventional fly ashes used separately and in the form of mixtures. The beneficial effect of fluidized beds boiler fly ashes on the physical properties of cement mortars has been shown, i.e. reduction of the contraction, decrease of weight loss and reduction of the destruction of mortars in acid corrosion. This effect was especially beneficial for mortars containing higher (45% by weight) content of fluidized fly ashes, used separately and in the form of mixtures, regardless of the aggressiveness of the environment (1%, 3% and 5% HCl solution).
Źródło:
Roczniki Inżynierii Budowlanej; 2016, 16; 101-109
1505-8425
Pojawia się w:
Roczniki Inżynierii Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania akumulacji rtęci w popiołach lotnych z kotłów fluidalnych
Investigation of the accumulation of mercury by fluidized bed boiler fly ashes
Autorzy:
Kobyłecki, R.
Wichliński, M.
Bis, Z.
Powiązania:
https://bibliotekanauki.pl/articles/282716.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
kotły fluidalne
popiół lotny
adsorpcja rtęci
fluidized bed boilers
fly ash
mercury adsorption
Opis:
W pracy przedstawiono wyniki badań zawartości rtęci w próbkach popiołu lotnego z kotłów fluidalnych opalanych węglem kamiennym i brunatnym. W oparciu o uzyskane wyniki stwierdzono, że im drobniejsza jest frakcja ziaren popiołu lotnego, tym więcej zawiera ona części palnych oraz rtęci. Wyniki badań wskazują na istnienie korelacji między zawartością części palnych, a zawartością rtęci. Przeprowadzone badania wymywania zaadsorbowanej w popiołach lotnych Hg0 wykazały, że ponad 70% rtęci atomowej jest trwale zaadsorbowane na ziarnach popiołu.
The paper contains results of experimental investigations associated with determination of mercury concentration in fly ash samples from Polish fluidized bed boilers fired with hard and brown coals. The results indicate that the finer the fly ash particles the more unburned carbon and mercury they contain. A correlation between the concentrations of unburned carbon and mercury has been demonstrated. The investigations re. the mercury leaching from the fly ash samples indicate that over 70% of atomic mercury that has been adsorbed by the fly ash particles is not leached but remains within the particles.
Źródło:
Polityka Energetyczna; 2009, T. 12, z. 2/2; 285-293
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Co-Combustion of Municipal Sewage Sludge and Hard Coal on Fluidized Bed Boiler WF-6
Współspalanie komunalnych osadów ściekowych z węglem kamiennym w kotle fluidalnym WF-6
Autorzy:
Rajczyk, R.
Bień, J.
Palka, H.
Pogodziński, A.
Smorąg, H.
Powiązania:
https://bibliotekanauki.pl/articles/950772.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
municipal sewage sludge
co-combustion
bubbling fluidized bed boiler
osady ściekowe komunalne
współspalanie
kocioł fluidalny
Opis:
According to data of the Central Statistical Office, the amount of sludge produced in municipal wastewater treatment plants in 2010 amounted to 526000 Mg d.m. The forecast of municipal sewage sludge amount in 2015 according to KPGO2014 will reach 642400 Mg d.m. and is expected to increase in subsequent years. Significant amounts of sludge will create problems due to its utilization. In order to solve this problem the use of thermal methods for sludge utilization is expected. According to the National Waste Management Plan nearly 30% of sewage sludge mass should be thermally utilized by 2022. The article presents the results of co-combustion of coal and municipal sewage sludge in a bubbling fluidized bed boiler made by SEFAKO and located in the Municipal Heating Company in Morag. Four tests of hard coal and sewage sludge co-combustion have been conducted. Boiler performance, emissions and ash quality were investigated.
Według danych GUS w 2010 r. ilość osadów ściekowych wytworzonych w oczyszczalniach komunalnych wyniosła 526,1 tys. Mg s.m. Natomiast prognozowana wg KPGO2014 na 2015 r. ilość suchej masy komunalnych osadów ściekowych osiągnie poziom 642,4 tys. Mg i będzie dalej zwiększać się w kolejnych latach. Znaczne ilości osadów będą stwarzać problemy w ich zagospodarowaniu. W celu rozwiązania tego problemu stawia się na wykorzystanie termicznych metod unieszkodliwiania osadów. Zgodnie z zapisami Krajowego Planu Gospodarki Odpadami (KPGO2014) przewiduje się wręcz, że w perspektywie do 2022 r. ponad 30% osadów będzie termicznie utylizowane. W artykule przedstawiono wyniki badań procesu współspalania czterech mieszanek na bazie węgla i komunalnych osadów ściekowych przeprowadzonych w kotle fl uidalnym z warstwą pęcherzykową WF-6 produkcji SEFAKO zlokalizowanym w Miejskim Przedsiębiorstwie Energetyki Cieplnej w Morągu. Podczas badań określono towarzyszące temu procesowi emisje, skład powstających popiołów jak również wpływ współspalania na parametry ruchowe kotła.
Źródło:
Archives of Environmental Protection; 2014, 40, 3; 101-113
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the similarity theory in model investigations of a ships fluidized bed boiler
Zastosowanie teorii podobieństwa w badaniach modelowych okrętowego kotła fluidalnego
Autorzy:
Adamkiewicz, A.
Zeńczak, W.
Powiązania:
https://bibliotekanauki.pl/articles/359479.pdf
Data publikacji:
2010
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
teoria podobieństwa
współczynnik przejmowanie ciepła
warstwa fluidalna
kocioł okrętowy
theory of similarity
heat transfer coefficient
fluidized bed
ship boiler
Opis:
In model investigation of ship's fluidised bed boiler the similarity theory has been applied, which permits to transfer the investigation results from the model to the real object. For setting the non- dimensional numbers in similar phenomena, the analysis of differential equations describing the examined phenomenon or the dimensional analysis is applied. The article presents an example of the search for the non-dimensional numbers characterising the phenomenon of heat exchange in ship's fluidised bed boiler.
W badaniach modelowych okrętowego kotła fluidalnego wykorzystano teorię podobieństwa pozwalającą na przenoszenie wyników badań z modelu na obiekt rzeczywisty. Dla ustalenia modułów bezwymiarowych w zjawiskach podobnych stosuje się analizę równań różniczkowych, opisujących rozpatrywane zjawisko lub też analizę wymiarową. W artykule przedstawiono przykład poszukiwania modułów bezwymiarowych charakteryzujących zjawisko wymiany ciepła w okrętowym kotle fluidalnym.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2010, 23 (95); 5-9
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uszkodzenie wykładziny ceramicznej oddzielacza popiołu kotła fluidalnego na skutek współspalania węgla i biomasy
Damage to the ceramic lining of the ash separator of a fluidized bed boiler resulting from combined combustion of coal and biomass
Autorzy:
Stryszewska, T.
Kańka, S.
Powiązania:
https://bibliotekanauki.pl/articles/163703.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
kocioł fluidalny
oddzielacz popiołu
okładzina ceramiczna
zniszczenie
przyczyna
fluidized bed boiler
ash separator
ceramic lining
damage
cause
Opis:
W artykule przedstawiono wyniki badań dotyczących określenia przyczyny zniszczenia wykładziny ceramicznej w oddzielaczu popiołu kotła fluidalnego. Szybki postęp degradacji przedmiotowej wykładziny zaobserwowano po wprowadzeniu biomasy jako dodatkowego składnika paliwa energetycznego.
This article presents the results of tests to determine the reasons for damage to the ceramic lining in the ash separator of a fluidized bed boiler. The rapid progress of degradation of the lining was observed after biomass was introduced as an additional component of the combusted fuel.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 5, 5; 115-118
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości zagospodarowania popiołów z termicznego przekształcania osadów ściekowych w kotłach fluidalnych
Possibilities of ashes utilization from sewage sludge thermal processing in a fluidized bed boiler
Autorzy:
Borowski, G.
Gajewska, M.
Haustein, E.
Powiązania:
https://bibliotekanauki.pl/articles/297254.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
osad ściekowy
spalanie fluidalne
popiół
zestalenie
zeszkliwienie
sewage sludge
fluidized bed combustion
ash
solidification
vitrification
Opis:
Problem zagospodarowywania osadów ściekowych dotyczy głównie ich wykorzystania rolniczego, w tym rekultywacji terenów zdegradowanych. Zmiana wymagań prawnych i środowiskowych spowodowała konieczność poszukiwań nowych sposobów ich unieszkodliwiania. W Polsce od kilku lat obserwuje się wzrost zainteresowania termiczną metodą przekształcania osadów ściekowych. Zastosowana technologia spalania fluidalnego sprzyja zmniejszeniu ilości wytwarzanych i zdeponowanych osadów ściekowych. Ich termiczne przekształcanie nie eliminuje jednak problemu występowania m.in. metali ciężkich w uzyskanych popiołach, a jedynie prowadzi do związania ich w formy bardziej stabilne, ograniczając w ten sposób stopień szkodliwości dla środowiska naturalnego. W artykule zaprezentowano metodę zestalania popiołów powstałych z termicznego przekształcania osadów ściekowych w blokach cementowych. Analizując właściwości popiołów z fluidalnego spalania osadów ściekowych, zaproponowano koncepcję alternatywnego rozwiązania - ich przetworzenie w postać zeszklonych mikrokulek. Proponowana metoda zapewni neutralizację substancji niebezpiecznych w nich zawartych. Omówiono potencjalne korzyści ekologiczne i ekonomiczne oraz wymieniono dziedziny potencjalnego wykorzystania gospodarczego w zależności od wielkości średnic mikrokulek. Mikrokulki szklane mogą być, między innymi, stosowane w przemyśle tworzyw sztucznych do uzyskania wytrzymałych wyrobów z PCV, a także jako zamiennik tzw. proppantów w procesie szczelinowania hydraulicznego przy wydobyciu gazu łupkowego i ropy naftowej.
The problem of sewage sludge processing relates mainly to its agricultural use, including the restoration of degraded land. Changing the legal and environmental requirements made it necessary to search for new techniques of disposal. In Poland, for several years there has been increased interest in using thermal treatment of sewage sludge. The used technology of fluidized bed combustion helps to reduce the amount of generated and deposited sludge. The thermal processing does not eliminate the problem of occurrence of heavy metals in the ash obtained, only results in binding them in the more stable form, thus reducing the degree of harmfulness to the environment. The paper presents a method for solidification of ash from the incineration of sewage sludge in cementitious compositions. Analyzing the characteristics of ashes from fluidized bed combustion of sewage sludge, there was proposed the concept of alternative solutions - processing in the form of vitrified microspheres. The proposed method provides neutralizing the hazardous substances contained therein. The potential environmental and economic benefits, and outlined areas of potential economic use, depending on the size of the diameter of the microspheres, were discussed. Glass microspheres may be, inter alia, used in the plastics industry to get durable PVC products, and also as a replacement of ‘proppants’ in hydraulic fracturing of the shale gas and oil.
Źródło:
Inżynieria i Ochrona Środowiska; 2014, 17, 3; 393-402
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zmian obciążenia kotła fluidalnego na zawartość rtęci w popiele lotnym
Impact of changes in fluidized bed boiler load on the content of mercury in fly ash
Autorzy:
Wichliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/394977.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
rtęć
popiół lotny
kotły fluidalne
obciążenie kotła
mercury
fly ash
fluidized bed boilers
boiler load
Opis:
W pracy przedstawiono wyniki badań zawartości rtęci w popiołach lotnych pozyskanych z jednej z polskich elektrowni. Elektrownia była wyposażona w kocioł fluidalny o mocy 70 MW. Podczas badań kocioł pracował ze stałym obciążeniem przy 50, 75 i 100-procentowej mocy nominalnej, każdy test trwał 48 godzin, pomiędzy testami były 24-godzinne przerwy aby zapewnić pełną wymianę złoża warstwy fluidalnej. Kocioł spalał węgiel kamienny i muł węglowy w ilości około 10%. Do badań pobrano próbki paliw i popiołów, przeprowadzono analizę zawartości rtęci w paliwie wprowadzanym do kotła, jak również w popiele lotnym opuszczającym kocioł. W badaniach zbadano również zawartość niespalonego węgla w popiele lotnym, oznaczoną jako LOI. Wyniki badań pokazały, że największą zawartość rtęci miał popiół lotny pobrany z kotła przy obciążeniu 50% (475 ng/g), wraz ze wzrostem obciążenia do 75%, zawartość rtęci zmalała do poziomu 320 ng/g. Przy obciążeniu nominalnym zawartość rtęci wynosiła około 385 ng/g. Ilość niespalonego węgla w popiele lotnym rosła wraz ze wzrostem obciążenia kotła od 7% przy obciążeniu 50%, a do 9% przy obciążeniu 100%.
This paper presents the results of the mercury content in fly ash obtained from one of the Polish power plants. The power plant was equipped with a fluidized bed boiler with a capacity of 70 MW. During the test the boiler working at a constant load at 50, 75 and 100% of nominal power, each test lasted 48 hours there were 24 hour intervals between tests to ensure the full exchange of the fluidized bed. The boiler burned hard coal and coal slurries in at the level of about 10%. Test samples of fuel and ash were analyzed by the mercury content of the fuel introduced into the boiler as well as the fly ash leaving the boiler. The study also examined the content of unburned carbon in the fly ash, designated as LOI. Results show that the highest mercury content of the fly ash was obtained from the boiler load of 50% (475 ng/g), as the load increases to 75%, the mercury content decreased to the level of 320 ng/g. At nominal load, the mercury content was approximately 385 ng/g. The amount of unburned carbon in the fly ash increased with the boiler load of 7% at a load of 50% to 9% at 100% load.
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2016, 95; 129-136
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of platen superheaters in a circulating fluidized bed boiler at different loads
Modelowanie grodziowych przegrzewaczy pary dla różnych obciążeń w kotle z cyrkulacyjnym złożem fluidalnym
Autorzy:
Madejski, P.
Taler, D.
Korzeń, A.
Powiązania:
https://bibliotekanauki.pl/articles/172817.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wymiennik ciepła
przegrzewacz pary
cyrkulacyjne złoże fluidalne
rozkład temperatury pary
heat exchanger
steam superheater
circulating fluidized bed
temperature distribution of steam
Opis:
Przegrzewacz pary drugiego stopnia jest to przegrzewacz grodziowy wykonany z rur „podwójną omega”. Przegrzewacz jako wymiennik ciepła, zbudowany jest z trzech biegów. Każdy bieg jest wykonany z innego gatunku stali niskostopowej. W artykule przedstawiono obliczenia rozkładu temperatur pary, jak również ścianki rury grodziowego przegrzewacza, dla rożnych obciążeń kotła z cyrkulacyjnym złożem fluidalnym (CFB).
A second stage steam superheater is a platen superheater made from so-called ‘double omega’ tubes. The superheater is a three-pass tube heat exchanger. Each pass is made from different low-alloy steel. In the paper, the temperature distributions of the steam and tube wall in the platen superheater were computed at different partial loads of a circulating fluidized bed (CFB) boiler.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 85-92
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On line diagnostics and self-tuning method for the fluidized bed temperature controller
Autorzy:
Porzuczek, J.
Powiązania:
https://bibliotekanauki.pl/articles/240482.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fluidized bed boiler
bed temperature
temperature control
statistical process control
kocioł fluidalny
temperatura złoża
regulacja temperatury
statystyczne sterowanie procesem
Opis:
The paper presents the method of on-line diagnostics of the bed temperature controller for the fluidized bed boiler. Proposed solution is based on the methods of statistical process control. Detected decrease of the bed temperature control quality is used to activate the controller self-tuning procedure. The algorithm that provides optimal tuning of the bed temperature controller is also proposed. The results of experimental verification of the presented method is attached. Experimental studies were carried out using the 2 MW bubbling fluidized bed boiler.
Źródło:
Archives of Thermodynamics; 2016, 37, 1; 31-46
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An appraisal of the properties of bottom waste obtained from bio-mass congestion to estimate the ways of its environmental use
Autorzy:
Śliwka, M.
Uliasz-Bocheńczyk, A.
Pawul, M.
Powiązania:
https://bibliotekanauki.pl/articles/778179.pdf
Data publikacji:
2017
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
bottom waste
bottom ashes
bio-mass combustion
bio-mass
fluidized-bed boiler
bio-tests
phytotests
energy wastes
furnace waste
Opis:
The bottom waste obtained from bio-mass burning shows a huge variability of chemical and physical properties, depending on the kind of bio-mass, the type of a cauldron and burning parameters. The huge variability of the bottom ashes from the incineration plant and co-combustion of bio-mass makes it difficult to find any way to its management. In reality, only the bottom ashes from coal combustion and the small amount from lignite combustion are used, mainly in the building industry and in mining industry. The article presents the initial research, concerning the estimation of the properties of the bottom ashes obtained from bio-mass congestion in the fluidized-bed boiler to use them safely for the environment. To determine the influence of the tested waste on plants, a number of pot experiments have been conducted. The plants which have been used are recommended for phytotoxicity estimation, and are also used for biological reclamation.
Źródło:
Polish Journal of Chemical Technology; 2017, 19, 2; 33-37
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Popioły lotne z kotłów fluidalnych jako składniki popiołowo-cementowych spoiw drogowych
Fly ash from fluidized bed boilers as component of fly ash-opc road binders
Autorzy:
Gawlicki, M.
Wons, W.
Powiązania:
https://bibliotekanauki.pl/articles/392338.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
kocioł fluidalny
popiół lotny
wykorzystanie odpadów
drogownictwo
spoiwo drogowe
fluidized bed boiler
fly ash
waste utilization
road engineering
road binder
Opis:
Popioły lotne z kotłów fluidalnych są wykorzystywane w drogownictwie w stosunkowo niewielkich ilościach. Projekt normy prEN 13282-2:2010 wymienia je jednak jako jeden ze składników głównych hydraulicznych spoiw drogowych. W pracy przedstawiono wstępną ocenę możliwości takiego wykorzystania popiołów lotnych oraz dokonano klasyfikacji zawierających je spoiw w oparciu o kryteria prEN 13282-2:2010. Wskazano również na konieczność wykonywania badań wytrzymałościowych spoiw nie na zaprawach o stałym w/s, lecz na zaprawach o określonej konsystencji. Badania wykazały, że zgodnie z kryteriami prEN 13282-2:2010 omawiane spoiwa w zależności od składu można zaklasyfikować do klas od N1 do N4.
Fly ash from fluidized bed boilers are used in road construction in relatively small amounts. However, the draft standard prEN 13282-2:2010, classifies them as a one of the main components of the road hydraulic binders. This paper presents a preliminary assessment of the implementation, as well as the classification of hydraulic road binders containing this fly ash in accordance with the criteria of prEN 13282-2:2010. The studies have shown the need to perform the strength tests not at the constant w/b ratio in the mortars, but on the mortars of constant consistency. The road binders discussed in this paper can be classified to the N1–N4 class according to the compressive strength criteria given in the prEN 13282-2:2010.
Źródło:
Prace Instytutu Ceramiki i Materiałów Budowlanych; 2011, R. 4, nr 8, 8; 69-78
1899-3230
Pojawia się w:
Prace Instytutu Ceramiki i Materiałów Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Emissions of CO2, CO, NOx and N2O from dried lignite combustion in oxygen-enriched O2/CO2 atmospheres in a circulating fluidized bed boiler
Autorzy:
Krzywański, J.
Czakiert, T.
Muskała, W.
Nowak, W.
Pacyna, J.
Powiązania:
https://bibliotekanauki.pl/articles/175342.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
oxy-coal combustion
CFB
combustion
modeling
Opis:
The paper presents the idea of oxygen-enhanced dried lignite combustion in a circulating fluidized bed (CFB) boiler as it gives a possibility of reduction of gaseous pollutants emissions. Calculations were conducted using one-dimensional model, which describes crucial processes associated with combustion of solid fuels under circulating fluidized bed conditions, e.g., hydrodynamics of bed material, fuel devolatilization, volatiles and char combustion and heat transfer. The paper is focused on CO2, CO, NOx and N2O emissions from a 670 t/h CFB boiler during dried lignite combustion in O2/CO2 atmosphere. The dependence of the gaseous pollutants’ emissions on oxygen fraction in an inlet gas as well as moisture content in lignite were studied. The oxygen fraction was increased from 21 to 30% vol., whereas moisture content was decreased from 43.5 to 10% – simulating fuel pre-drying. A case study considers solution when process is run with recirculation of CO2. The obtained results was compared to the case where CO2 is not recycled.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 132; 71-85
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Konwersja kotła pyłowego węglowego OB230p na kocioł fluidalny biomasowy BFB220 oraz przystosowanie turbiny TG5 do pracy w układzie kogeneracyjnym
Autorzy:
Roszak, Waldemar
Powiązania:
https://bibliotekanauki.pl/articles/2096859.pdf
Data publikacji:
2021
Wydawca:
Nowa Energia
Tematy:
technologie
kocioł pyłowy
kocioł węglowy
kocioł fluidalny
kocioł biomasy
układ kogeneracyjny
technologies
dust boiler
coal boiler
fluidized bed boiler
biomass boiler
cogeneration system
Opis:
ZE PAK S.A. w 2020 r. zlecił firmie Valmet Technologies realizację w formule „pod klucz” kontraktu na zaprojektowanie i wykonanie przebudowy kotła węglowego K-7 w Elektrowni Konin na kocioł fluidalny pracujący w technologii BFB. W ramach prac modernizacyjnych zlecono również firmie Etos Energy przystosowanie turbiny TG-5 (typu TK50) do pracy w kogeneracji. Kocioł K7 z turbogeneratorem TG5 i instalacjami pomocniczymi stanowi nowy blok nr 5.
Źródło:
Nowa Energia; 2022, 2; 56-60
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody wyznaczania rozkładów ziarnowych wykorzystywanych w badaniach laboratoryjnych aerodynamiki cyrkulacyjnej warstwy fluidalnej
Methods of determination of particle size distributions of inert materials used in laboratory studies of circulating fluidized bed boiler hydrodynamics
Autorzy:
Ziaja, J.
Mirek, P.
Powiązania:
https://bibliotekanauki.pl/articles/297096.pdf
Data publikacji:
2017
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
fluidization
aerodynamics of fluidized
fluidized bed boiler
sieve analysis
laser diffraction methods
fluidyzacja
aerodynamika cyrkulacyjnej warstwy fluidalnej
kocioł fluidalny
analiza sitowa
dyfrakcja laserowa
Opis:
The paper presents the results of investigations concerning the influence of the method of determination of particle size distributions on the modeling of aerodynamics of circulating fluidized bed in laboratory conditions. The advantages and disadvantages of the most commonly used sieve analysis and laser diffraction methods are presented, showing that these methods cannot always be used interchangeably. Based on the obtained results, a discussion on the influence of basic parameters of particle diameter distributions on key parameters characterizing the aerodynamics of the circulating fluidized bed.
W artykule omówiono rezultaty badań dotyczących wpływu metody określania rozkładów ziarnowych na modelowanie aerodynamiki cyrkulacyjnej warstwy fluidalnej w warunkach laboratoryjnych. Przedstawiono wady i zalety najczęściej stosowanych metod analizy sitowej oraz dyfrakcji laserowej, wykazując, że metody te nie zawsze mogą być wykorzystywane zamiennie. Na podstawie otrzymanych wyników badań przeprowadzono dyskusję nad wpływem podstawowych parametrów rozkładów średnicy ziaren na kluczowe wielkości charakteryzujące aerodynamikę cyrkulacyjnej warstwy fluidalnej.
Źródło:
Inżynieria i Ochrona Środowiska; 2017, 20, 2; 249-261
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odpady denne z kotłów fluidalnych - charakterystyka fizykochemiczna, ocena zagrożenia dla środowiska i możliwości zagospodarowania w produkcji klinkieru portlandzkiego
Bottom waste from fluidized-bed boilers - physico-chemical characteristics, environmental risk assesment and development possibilities in the production of portland cement clinker
Autorzy:
Janecka, L.
Siemiątkowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/392296.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
kocioł fluidalny
opad denny
charakterystyka fizykochemiczna
zastosowanie
produkcja klinkieru
fluidized-bed boiler
bottom waste
physical and chemical characteristics
utilization possibility
clinker production
Opis:
Wprowadzenie kotłów fluidalnych spowodowało pojawienie się nowych odpadów o odmiennym, w stosunku do odpadów z kotłów konwencjonalnych, składzie i właściwościach. W wyniku spalania paliw w kotłach fluidalnych powstają produkty uboczne takie jak: popioły lotne, odpady denne, niespalony węgiel i nieprzereagowany sorbent. Ze względu na niższą temperaturę spalania oraz zastosowanie wapieni do neutralizacji tlenków siarki w złożu fluidalnym, popioły lotne i odpady denne z palenisk fluidalnych znacznie różnią się od powstających w paleniskach pyłowych i warstwowych. W publikacji przedstawiono charakterystykę fizykochemiczną odpadów dennych, oceniono ich potencjalne zagrożenia dla środowiska naturalnego oraz wstępnie oceniono możliwości zagospodarowania w produkcji klinkieru portlandzkiego.
The use of fluidised-bed boilers caused the appearance of new wastes of different composition and properties in relation to wastes from conventional boilers. As a result of fuel combustion in fluidized-bed boilers arises by-products, such as: fly ashes, bottom wastes, unburned carbon and unreacted sorbent. Due to the lower combustion temperature and the use of limestone for sulphur oxides neutralization in fluidized bed, fly ashes and bottom wastes from fluidized bed differs significantly from those rising in dust and layered furnaces. In this publication a bottom wastes physico-chemical characteristics, potential risk for natural environment was evaluated and development possibilities in the production of Portland cement clinker were initially evaluated.
Źródło:
Prace Instytutu Ceramiki i Materiałów Budowlanych; 2012, R. 5, nr 9, 9; 89-101
1899-3230
Pojawia się w:
Prace Instytutu Ceramiki i Materiałów Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka popiołów ze spalania biomasy w kotłach fluidalnych
Characteristics of ash from the combustion of biomass in fluidized bed boilers
Autorzy:
Uliasz-Bocheńczyk, A.
Pawluk, A.
Pyzalski, M.
Powiązania:
https://bibliotekanauki.pl/articles/215950.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
popiół lotny
spalanie biomasy
kocioł fluidalny
skład chemiczny
wymywalność
skład fazowy
fly ash
biomass combustion
fluidized bed boiler
chemical composition
leachability
phase composition
Opis:
Energetyka zawodowa w zakresie wytwarzania energii ze źródeł odnawialnych wykorzystuje przede wszystkim biomasę, która jest stosowana jako paliwo podstawowe lub w procesie współspalania z węglem. Tak jak w przypadku węgla również przy wykorzystaniu biomasy w energetyce zawodowej powstają uboczne produkty spalania, przede wszystkim w postaci popiołów lotnych. Produkty te różnią się znacząco od tych pozyskanych ze spalania węgla. O ich właściwościach decyduje przede wszystkim rodzaj spalanej biomasy i typ kotła. Ze względu na coraz większy nacisk związany z wykorzystaniem energii ze źródeł odnawialnych, wynikający z wymogów Polityki Energetycznej Polski oraz z przepisów UE, powstaje coraz więcej tego typu odpadów. Popioły ze współspalania biomasy są materiałem stosunkowo dobrze scharakteryzowanym, szczególnie z kotłów konwencjonalnych. Uboczne produkty spalania biomasy są odpadami, które ze względu na właściwości mają ograniczone możliwości wykorzystania gospodarczego. Szczególnie problematyczne są popioły ze spalania w kotłach fluidalnych. W artykule przedstawiono wyniki badań podstawowych właściwości trzech popiołów ze spalania biomasy w kotłach fluidalnych oraz jednego – porównawczo – ze współspalania biomasy z węglem kamiennym w kotle pyłowym przy zastosowaniu tego samego rodzaju biopaliwa. [...]
When it comes to the production of energy from renewable sources, biomass is the main fuel, burned directly or co-fired with coal, used in the professional power industry. As in the case of coal, the use of biomass in the professional power industry is accompanied by the generation of by-products of the combustion process, primarily in the form of fly ash. These wastes significantly differ from those resulting from coal combustion. Their properties depend primarily on the burned biomass and boiler type. Due to the growing pressure on the use of energy from renewable sources resulting from the Energy Policy of Poland and the requirements imposed by the EU, more and more by-products are produced. Ashes from the co-firing of biomass are relatively well studied, especially when it comes to those resulting from the combustion in conventional boilers. The by-products of biomass combustion are of limited economic use due to their specific characteristics. The ashes resulting from the combustion in fluidized bed boilers are particularly problematic. The paper presents the research results on the basic properties of the three ashes generated from the combustion of biomass in fluidized bed boilers and one ash resulting from the co-firing of biomass with coal in pulverized coal boiler for the same biofuel type. [...]
Źródło:
Gospodarka Surowcami Mineralnymi; 2016, 32, 3; 149-162
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena sygnałów procesowych z kotła energetycznego pod względem ich przydatności diagnostycznej
Evaluation of the power boiler process signals regarding their diagnostic applicability
Autorzy:
Jankowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/277665.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
sztuczne sieci neuronowe
kotły fluidalne
wczesna detekcja awarii kotłów energetycznych
analiza wrażliwości
artificial neural network
fluidized bed boiler
early boiler fault detection
sensitivity analysis
Opis:
Przedstawiono zastosowanie sztucznych sieci neuronowych do wczesnej detekcji stanu narastania nieszczelności parowych w obrębie komory spalania kotła energetycznego. Zestaw proponowanych w literaturze sygnałów wrażliwych na przeciek rozszerzono o dalsze zmienne pomiarowe osiągając znacznie lepszą jakość klasyfikacji niż przy minimalnym zestawie 3-4 zmiennych. Jako sieci klasyfikujące zbadano struktury radialne Radial Basis Function (RBF) oraz struktury wielowarstwowego perceptronu Multilayer Perceptron (MLP) o jednej lub dwu warstwach ukrytych, uczone metodami z nauczycielem. Redukcję rozważanego początkowo zbioru zmiennych wejściowych prowadzono poprzez analizę wrażliwości uzyskanych sieci, testując ich zdolności generalizacji na nieznanych sytuacjach awarii tego samego typu. Uzyskano klasyfikację przekraczającą 90% poprawnego przyporządkowania stanów procesu na nieznanych na etapie uczenia przypadkach niesprawności. W niezależnych testach na 11 awariach potwierdzono większą przydatność w omawianym zadaniu struktur MLP niż RBF, mimo wyższej wrażliwości sieci RBF na sygnały wejściowe.
An application of artificial neural networks for early detection of rising steam leaks and leaks within the combustion chamber of power unit, is presented. A set of signals sensitive to leakage proposed in the literature has been supplemented with further measuring variables enabling reaching significantly better classification quality than with the minimum set of 3-4 variables. As classification networks the Radial Basis Function (RBF) and Multilayer Perceptron (MLP) having one or two hidden layers trained with the teacher, were examined. Reduction of input variables belonging to the considered set was realised with sensitivity analysis of resulting networks, testing their generalisation ability on unknown failure situations of the same type. Classification exceeding 90% of proper process states attribution for unknown during the learning phase faults cases was obtained. The 11 independent test cases confirmed that for discussed tasks MLP structures were more useful than RBF ones, despite higher sensitivity of RBF networks to input signals.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 11; 79-83
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Popioły ze spalania biomasy w kotłach fluidalnych
Fly ash from fluidized-bed combustion of 100% biomass
Autorzy:
Gawlicki, Marek
Jarosz-Krzemińska, Elżbieta
Poluszyńska, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/392278.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
elektrociepłownia
biopaliwo
popiół lotny
skład chemiczny
biomasa
kocioł fluidalny
rośliny energetyczne
power plant
biofuel
fly ash
chemical composition
biomass
fluidized bed boiler
energy crops
Opis:
Uruchomienie w elektrowniach i elektrociepłowniach „zielonych bloków”, w kotłach których w złożu fluidalnym spalane są wyłącznie biopaliwa, spowodowało powstanie popiołów lotnych znacząco różniących się od pozostałych rodzajów ubocznych produktów spalania. Jako biopaliwa wykorzystywane są w Polsce głównie zrębki drzewne, ale mogą być również spalane różnego rodzaju pellety, oraz odpady z upraw i odpady z przetwarzania produktów rolnych, a także biomasa pozyskiwana z plantacji roślin energetycznych. W pracy omówiono skład chemiczny popiołów ze spalania wielu rodzaju roślin oraz porównano je ze składem chemicznym popiołów lotnych pobranych z instalacji przemysłowych zielonych bloków energetycznych.
Biomass combustion in fluidized-bed boilers resulted in generation of an entirely new type of waste, which differs significantly from other types of combustion by-products. In Poland mainly wood chips are used as biofuel, but also various types of pellets, crop waste, processing waste of agricultural origin or biomass obtained from energy plantations. The paper discusses the chemical composition of ash from the combustion of several types of plants which were then compared with the chemical composition of fly ash derived from industrial installations so-called “green power units”.
Źródło:
Prace Instytutu Ceramiki i Materiałów Budowlanych; 2018, R. 11, nr 34, 34; 7-19
1899-3230
Pojawia się w:
Prace Instytutu Ceramiki i Materiałów Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The preliminary research of the physico-mechanical properties of aggregates based on the colliery shale, supplemented by fly ash
Badania wstępne właściwości fizykomechanicznych kruszyw na bazie łupku przywęglowego z dodatkiem popiołu lotnego
Autorzy:
Blajer, Mateusz
Stopkowicz, Agnieszka
Adamczyk, Justyna
Cała, Marek
Powiązania:
https://bibliotekanauki.pl/articles/218673.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
właściwości fizyko-mechaniczne
popiół lotny z kotła fluidalnego
mieszanki kruszywowo-popiołowe
skała płona
physico-mechanical properties
waste rock
fly ash from fluidized bed boiler
aggregate mixes
Opis:
The currently applicable legal provisions and also the economic concepts emphasize the importance of circular economy. In this aspect, it is very important to reduce the waste production respectively planning and running a business. Technical research is the key to finding a new applications for waste, in particular disposed on landfilling. Mining and energy industries belong to the biggest producers of waste in Poland. The total share of these two branches in waste production is up to 70% (mining and quarrying 53%; electricity, gas, steam and air conditioning supplay 17%). In environment, economy and social aspect, it is very important to develop this waste. The paper presents research on the physico-mechanical properties of the aggregates based on colliery shale supplemented by fly ash (20% - 40% supplement of fly ash). The following tests should be mentioned among performed: particle size distribution, the sand equivalent test, freeze resistance and direct shear tests. Also the chemical properties found in the literature was invoked. The research shows good physico-mechanical properties of the mixes, such as cohesion (44.62 kPa - 68.57 kPa) or internal firiction angle (34.74° - 40.52°). Though low resistance to weathering and a large susceptibility to frost heave (the mass loss after the freezing cycles is 76%) may limit its applicatin in road engineering. The sand equivalent tests were made only for aggregates. Tested materials shows usefulness for earthen structures. However, the research should be supplemented by chemical tests and also observations of the material properties changes as the effect of time. The research on the leachability of chemical pollutants, which will determine the acceptable share of ash in the mix, could be especially significant. The fact that fly ash contains a lot of sulphates and chlorides, which leach into the environment may pose a threat to living organisms.
Aktualne przepisy prawa oraz koncepcje gospodarcze obowiązujące w Polsce kładą duży nacisk na gospodarkę o obiegu zamkniętym. W tym aspekcie bardzo ważne staje się ograniczanie liczby odpadów odpowiednio planując oraz prowadząc działalność gospodarczą. Dlatego, poprzez badania poszukuje się rozwiązań, które pozwoliłyby na znalezienie nowych zastosowań dla odpadów, w szczególności unieszkodliwianych poprzez składowanie. Energetyka i górnictwo to dwie gałęzie przemysłu, których udział w produkcji odpadów jest największy. W Polsce oba sektory wytwarzają łącznie około 70% odpadów (górnictwo 53%; energetyka 17%). Zagospodarowanie tych odpadów jest bardzo ważne w aspekcie środowiskowym, ekonomicznym jak i społecznym.W artykule przedstawiono badania właściwości fizyko-mechanicznych dla mieszanek kruszywowo-popiołowych bazujących na łupku przywęglowym oraz popiele lotnym (20%-40% dodatku popiołu lotnego). Pośród przeprowadzonych badań należy wymienić: badanie wskaźnika piaskowego, badanie składu ziarnowego, badania mrozoodporności czy test bezpośredniego ścinania. Przywołano także właściwości chemiczne popiołów lotnych, które znaleziono w literaturze. Przeprowadzone badania wskazują na dobre właściwości fizyko-mechaniczne mieszanek kruszywowo-popiołowych takie jak kąt tarcia wewnętrznego (34.74°-40.52°) i spójność (44.62 kPa-68.57 kPa). Jednak niska mrozoodporność łupku przywęglowego (utrata masy po cyklach mrożenia wynosi 76%) wprowadza pewne ograniczenia co do możliwości zastosowania niniejszego materiału, w szczególności np. w drogownictwie. Badania wskaźnika piaskowego wykonano jedynie dla kruszyw, nie uwzględniając mieszanek. Badany materiał wykazuje potencjał do zastosowania przy wznoszeniu budowli ziemnych. Należy jednak przedstawione badania uzupełnić o badania chemiczne, a także uwzględnić w nich zmianę właściwości materiału pod wpływem czasu. Szczególnie ważne mogą okazać się badania wymywalności zanieczyszczeń chemicznych, które określą dopuszczalny udział popiołu w mieszance. Jest to związane z tym, że popioły lotne zawierają dużo siarczanów i chlorków, które wymywane do środowiska mogą stanowić zagrożenie dla organizmów żywych.
Źródło:
Archives of Mining Sciences; 2019, 64, 1; 21-34
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical optimization of air flow in the plenum chamber of an industrial CFB boiler
Autorzy:
Mirek, P.
Jabłoński, J.
Nowak, W.
Powiązania:
https://bibliotekanauki.pl/articles/1943239.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska
Tematy:
windbox
air distributor
circulating fluidized bed
Opis:
The article presents the results of experimental and numerical studies on windboxes operating in a 235MWe Circulating Fluidized Bed (CFB) boiler. The main problems of windbox designs have been identified and a modified internal geometry has been proposed which causes a more uniform flow under the grid and prevents the velocity field from formation of dead zones.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2008, 12, 3-4; 237-244
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A simplified methodolgy for scaling hydrodynamic data from Lagisza 460 MWC supercritical CFB boiler
Autorzy:
Mirek, P.
Powiązania:
https://bibliotekanauki.pl/articles/185646.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hydrodynamika
skalowanie
złoże fluidalne
hydrodynamics
circulating fluidized bed
scaling
Opis:
The paper presents the results of model studies on the hydrodynamics of the world's first supercritical circulating fluidized bed boiler Lagisza 460 MWe, carried out on a scale model built in a scale of 1/20 while preserving the full geometrical similarity. To reflect the macroscopic pattern of flow in the boiler's combustion chamber, tests were carried out based on two dimensionless flow dynamic similarity criteria, while maintaining a constant Froude number value between the commercial and the scaled-down units. A mix of polydispersion solids with its fractional composition determined by scaling down the particle size distribution of the boiler's inert material was utilised for the tests using a special scaling function. The obtained results show very good agreement with the results of measurements taken on the Lagisza 460 MWe supercritical CFB boiler.
Źródło:
Chemical and Process Engineering; 2011, 32, 4; 245-253
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekologiczne walory stosowania kotłów fluidalnych w sektorze komunalnym
Ecological features of using boilers with fluidized combustion bed in muncipal sector
Autorzy:
Pałamarczuk, P.
Konieczyński, J.
Powiązania:
https://bibliotekanauki.pl/articles/340677.pdf
Data publikacji:
2005
Wydawca:
Główny Instytut Górnictwa
Tematy:
kocioł fluidalny
kocioł
sektor komunalny
spalanie
zanieczyszczenia
boilers with fluidized
boiler
municipal sector
combustion
pollution
Opis:
Powietrze atmosferyczne na terenie Śląska zostało silnie zanieczyszczone przez procesy przemysłowe w ciągu ostatniego stulecia. Artykuł wskazuje na korzyści wynikające ze stosowania spalania fluidalnego. Wspomniane korzyści mają charakter ekologiczny - możliwość utylizacji różnych paliw, w tym biomasy oraz paliw niskiej jakości przy zachowaniu surowych norm emisyjnych. Opisano sposób redukcji emisji podstawowych zanieczyszczeń. Stosowanie palenisk fluidalnych umożliwia poczynienie wielu oszczędności: od przygotowania paliwa, przez wysoko sprawne przetwarzanie energii.
The Silesian atmosphere has been polluted since last century with the industrial processes. The article shows profits coming off using fluidal combustion. Refered profits has an ecological character - it's possible to utilize different fuels: biomass and waste fuels with keeping rigour emission norms. The ways of reduction basic pollution substances were described. Using fluidized combustions makes possible savings on preparing fuel and transforming energy.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2005, 3; 13-24
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Field testing of acoustic cleaning system working in 670MW CFB boiler
Autorzy:
Mirek, P.
Powiązania:
https://bibliotekanauki.pl/articles/185357.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic cleaners
circulating fluidized bed
ash fouling
odkurzacz akustyczny
zanieczyszczenia
popiół
Opis:
The article reports the results of measurements of the acoustic pressure of acoustic waves generated by acoustic dust cleaners mounted in the convection pass of the 670MWth Circulating Fluidised Bed boiler. Based on measurements carried out and the spectral analysis of recorded signals it was found that the level of acoustic pressure generated by acoustic cleaners for the frequency of 100 Hz was too low for the efficient cleaning of the heated surfaces of the reheater RH2 and superheater SH3.
Źródło:
Chemical and Process Engineering; 2013, 34, 2; 283-291
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of estimation of heat transfer coefficient between the fluidized bed and the surface immersed in it on an experimental simulation stand of a ship boiler
Metoda określania współczynnika przejmowania ciepła pomiędzy warstwą fluidalną a powierzchnią w niej zanurzoną na eksperymentalnym stoisku symulacyjnym kotła okrętowego
Autorzy:
Adamkiewicz, A.
Zeńczak, W.
Powiązania:
https://bibliotekanauki.pl/articles/359216.pdf
Data publikacji:
2010
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
współczynnik przejmowania ciepła
warstwa fluidalna
eksperyment
kocioł okrętowy
heat transfer coefficient
fluidized bed
ship boiler
Opis:
The paper defines the meaning of local and average heat transfer coefficient. The most frequently applied experimental methods for its estimation, particularly between the fluidized bed and the surface immersed in it, are presented. The method for the estimation of the influence of position and movement of fluidizing column on heat transfer coefficient is proposed.
W artykule zdefiniowano pojęcie lokalnego i średniego współczynnika przejmowania ciepła. Przedstawiono najczęściej stosowane eksperymentalne metody jego wyznaczania, w szczególności między warstwą fluidalną i zanurzoną w niej powierzchnią, również na tle własnej metody. Zaproponowano sposób określenia wpływu położenia kolumny fluidyzacyjnej, jak i jej ruchu na wartości współczynników przejmowania ciepła.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2010, 21 (93); 12-19
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie komputerowe przegrzewacza pary w kotle fluidalnym
CFD modeling of a CFB boiler superheater
Autorzy:
Ludowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/172952.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kocioł fluidalny
przegrzewacz pary
symulacja numeryczna
proces przepływowo-cieplny
fluidized bed boilers
superheater
computer simulation
flow-thermal process
Opis:
W pracy przedstawiono symulację komputerową przegrzewacza grodziowego drugiego stopnia usytuowanego w górnej części kotła fluidalnego OFz-425. Przegrzewacz zbudowany jest z rur omega o złożonym kształcie przekroju poprzecznego. Za pomocą trójwymiarowej symulacji numerycznej wyznaczony został rozkład temperatury w ściance rury oraz w przepływającej parze przy założeniu, że temperatura złoża fluidalnego w komorze paleniskowej jest znana. Wyniki obliczeń mogą być wykorzystane do prawidłowego doboru długości rur przegrzewacza oraz doboru gatunku stali na poszczególne biegi przegrzewacza. Pokazano również przykład rozwiązania odwrotnego zagadnienia wymiany ciepła występującego w regulacji temperatury pary przegrzanej przegrzewacza. Problem odwrotny polega na wyznaczeniu temperatury na wlocie rury przegrzewacza przy zadanej temperaturze na wylocie.
A computational fluid dynamics (CFD) simulation was carried out for the platen superheater placed in the combustion chamber of the OFe-425 CFB boiler. Superheater consists of omegatype tubes with complex shape of cross-section. Using the 3D numerical simulation determined was temperature distribution in the tube wall and flowing past steam at the assumption that temperature of fluidised bed in chamber is known. results of calculations can be used for appropriate selection of the superheater tube length as well as selection of the steel type for specific tube passes. Presented also is an example of inverse solution of heat transfer problem which is present in temperature control of superheated steam. The inverse problem is related to temperature distribution an inlet to the superheater at a given outlet temperature. Velocity, pressure, and temperature of the steam as well as the temperature of the tube wall with the complex cross section were computed using the ANSYS_CFX software. The direct and inverse problems were solved. In the inverse problem, the steam temperature at tube inlet waas determined based on the temperature at the outlet of the tube. The inverse problem was solved iteratively.
Źródło:
Archiwum Energetyki; 2011, 41, 2; 75-88
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of bed particle size in heat transfer to membrane walls of supercritical CFB boiler
Autorzy:
Błaszczuk, A.
Nowak, W.
Jagodzik, S.
Powiązania:
https://bibliotekanauki.pl/articles/240941.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat transfer coefficient
cluster renewal approach
bed particle size
suspension density
circulating fluidized bed
współczynnik wnikania ciepła
wielkość cząstek
gęstość zawiesiny
cyrkulacyjna warstwa fluidalna
Opis:
Experimental research has been carried out in a supercritical circulating fluidized bed combustor in order to indicate the effect of the bed particle size on bed-to-wall heat transfer coefficient. The bed inventory used were 0.219, 0.246 and 0.411 mm Sauter mean particles diameter. The operating parameters of a circulating fluidized bed combustor covered a range from 3.13 to 5.11 m/s for superficial gas velocity, 23.7 to 26.2 kg/(m2s) for the circulation rate of solids, 0.33 for the secondary air fraction and 7500 to 8440 Pa pressure drop. Furthermore, the bed temperature, suspension density and the main parameters of cluster renewal approach were treated as experimental variables along the furnace height. The cluster renewal approach was used in order to predict the bed-to-wall heat transfer coefficient. A simple semi-empirical method was proposed to estimate the overall heat transfer coefficient inside the furnace as a function of particle size and suspension density. The computationally obtained results were compared with the experimental data of this work.
Źródło:
Archives of Thermodynamics; 2014, 35, 3; 207-223
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A comparison of fuzzy logic and cluster renewal approaches for heat transfer modeling in a 1296 t/h CFB boiler with low level of flue gas recirculation
Autorzy:
Błaszczuk, A.
Krzywański, J.
Powiązania:
https://bibliotekanauki.pl/articles/240406.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fuzzy logic
heat transfer coefficient
cluster renewal approach
flue gas recirculation
circulating fluidized bed
logika rozmyta
współczynnik wnikania ciepła
recyrkulacja spalin
cyrkulacyjna warstwa fluidalna
Opis:
The interrelation between fuzzy logic and cluster renewal approaches for heat transfer modeling in a circulating fluidized bed (CFB) has been established based on a local furnace data. The furnace data have been measured in a 1296 t/h CFB boiler with low level of flue gas recirculation. In the present study, the bed temperature and suspension density were treated as experimental variables along the furnace height. The measured bed temperature and suspension density were varied in the range of 1131–1156 K and 1.93–6.32 kg/m3, respectively. Using the heat transfer coefficient for commercial CFB combustor, two empirical heat transfer correlation were developed in terms of important operating parameters including bed temperature and also suspension density. The fuzzy logic results were found to be in good agreement with the corresponding experimental heat transfer data obtained based on cluster renewal approach. The predicted bed-to-wall heat transfer coefficient covered a range of 109–241 W/(m2K) and 111–240 W/(m2), for fuzzy logic and cluster renewal approach respectively. The divergence in calculated heat flux recovery along the furnace height between fuzzy logic and cluster renewal approach did not exceeded ±2%.
Źródło:
Archives of Thermodynamics; 2017, 38, 1; 91-122
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-35 z 35

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies