Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "flow velocity measurement" wg kryterium: Wszystkie pola


Tytuł:
A Novel Simple Technique for Measuring the Volumetric Flow Rate and Direction of Flow Inside a Pipe – The Single and Double Coils Sensors
Autorzy:
Al Jarrah, Asem Mohammad
Powiązania:
https://bibliotekanauki.pl/articles/2204044.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
volumetric flow rate sensor
flow sensor
flow direction detection
velocity measurement
high speed velocity measurement
single coil sensor
double coils sensor
Opis:
This work shows how a single coil wrapped on a pipe can be used to measure the volumetric flow rate inside the pipe and how by wrapping a second coil the flow direction can be detected. The developed method is very simple, accurate, and cover all the range of flow from low speed to high speed with more accuracy expected at high speed. Few turns are sufficient for the coils, no calibration is needed, and the method can be used for all kinds of nonmagnetic fluids even, with less accuracy, without the need to know the type of fluid inside the pipe. The principle of the developed method is theoretically explained and proved and then experimentally validated.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 5; 290--298
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Absolutny pomiar bardzo małych prędkości przepływu gazu metodą fal cieplnych
Absolute measurement of very low gas flow velocity by means of thermal wave technique
Autorzy:
Rachalski, A.
Powiązania:
https://bibliotekanauki.pl/articles/155304.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
anemometria
fale cieplne
metoda absolutna
anemometry
thermal waves
absolute method
Opis:
Przedstawiono metodę absolutnego pomiaru prędkości przepływu gazu za pomocą fal cieplnych, w zakresie bardzo małych prędkości. Na podstawie rozwiązania analitycznego zjawiska propagacji fali cieplnej w płynącym gazie, prędkość przepływu wyznaczono metodą estymacji nieliniowej uprzednio zmierzonych przesunięć fazowych składowych harmonicznych fali w funkcji częstotliwości. Metoda umożliwia pomiar prędkości przepływu gazu rzędu kilku cm/s, bez uprzedniego wzorcowania czujnika.
The phenomenon of thermal wave propagation in a flowing gas is described by the equation of energy conservation (Eq. 1). Kiełbasa [1] solved this equation using the Green's function technique and he obtained the phase shift for a linear periodic heat source (Eq. 9). This formula expresses that the wave velocity depends not only on the gas velocity but also on the thermal diffusion. If the condition of Eq. 11 is fulfilled, Eq. 10 becomes Eq. 12., so the thermal wave velocity is equal to the flow velocity, and the method can be considered as absolute. Otherwise, the probe needs to be calibrated. As can be seen from Eq. 10, the less flow velocity, the bigger difference between the flow velocity and the wave velocity. Fig. 2 shows that the lower limit of the flow velocity is about 30cm/s for air flow. Instead of a sinusoidal wave we apply a complex signal described by Eq. 12. After decomposing detectors signal into harmonics, we obtain the phase shift related to each harmonic. The phase shift obeys the system of equations (Eq. 14), where flow velocity VG and thermal diffusivity are unknown parameters. The system can be solved by means of nonlinear estimation. Fig. 3 shows exemplary signals from the first and second detector. The results of estimation are presented in Fig. 4 and Tab. 1. The estimated values of both velocity and diffusivity are correct for the velocity equal to 7cm/s, while for the velocity of 50cm/s only the velocity value is correct. It is obvious that for this velocity the expression of Eq. 10 is insensitive to the thermal diffusivity, so the estimating procedure cannot find a proper value of the parameter. The presented method enables measurements of the gas flow velocity in the range of several cm/s without previous calibration of the probe. Further investigations will include searching an objective criterion of proper determination of the thermal diffusivity and improvement of the method accuracy.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 7, 7; 618-620
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pomiarów PIV prędkości przepływu cieczy przy dnie zbiornika kadzi wirowej napełnianej dwustronnie
PIV measurement analysis of fluid flow velocity occurring near the bottom of a two-sided filling whirlpool tank
Autorzy:
Jakubowski, M.
Sterczyńska, M.
Powiązania:
https://bibliotekanauki.pl/articles/2072466.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar PIV
kadź wirowa
napełnianie wielostronne
PIV measurement
cycling vat
whirlpool
multi-sided filling
Opis:
W pracy przedstawiono wyniki pomiarów PIV (Particle Image Velocimetry) wykonanych na zbiorniku modelowym kadzi wirowej o średnicy 7,75” (ok. 192 mm) wyposażonym w zastawy otworów wlotowych umożliwiających napełnianie dwustronne. Pomiar dotyczył obszaru przy dnie zbiornika, w którym zidentyfikowano występowanie przepływu wtórnego. Zbadano wpływ napełniania zwielokrotnionego na poprawę warunków formowania się przepływu odpowiedzialnego za powstawanie stożka osadu gorącego.
Results of PIV (Particle Image Velocimetry) measurements in relation tc a model vat tank of 7.75 in (ca 192 mm) in diameter, equipped with sets of inlets enabling two-sided filling are presented in the paper. The measu¬rement involved the area at a reservoir bottom in which the secondary flow occurred. The aim was to determine an influence of multi-sided filling on the improvement of conditions of the secondary flow responsible for the break cone formation.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 3; 185--186
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu czasu i sposobu eksploatacji kolektorów kanalizacji grawitacyjnej na prędkość przepływu ścieków
Influence of duration and exploitation manner of sanitation conduits on sewage flow velocity
Autorzy:
Pliżga, O.
Jlilati-Zgardzińska, A. W.
Florek, M.
Hanzel, J.
Jaromin-Gleń, K. M.
Łagód, G.
Powiązania:
https://bibliotekanauki.pl/articles/126511.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
kanalizacja grawitacyjna
osady ściekowe
samooczyszczanie kanałów
pomiar prędkości przepływu
prędkość przepływu
gravity sewerage
sewer sediments
sewer self-purification
flow velocity measurement
Opis:
Podczas projektowania sieci kanalizacji grawitacyjnej założenie stałego spadku dna odcinka kanału, podobnie jak niezmiennego pola przekroju oraz chropowatości, jest bliskie rzeczywistości. Spełnienie tych założeń zależy od jakości przewodów kanalizacyjnych oraz precyzji wykonania kanałów. Wszystkie wyżej wymienione elementy mają znaczący wpływ na średnie prędkości przepływu ścieków w kanalizacji grawitacyjnej i dobierane są w taki sposób, aby zapewnić hydrauliczne samooczyszczanie kanału z gromadzących się na dnie osadów. Przeprowadzone badania pokazują rzeczywistą prędkość średnią przepływu ścieków po wieloletniej eksploatacji w wybranych przewodach kanalizacyjnych. Zaprezentowano wyniki badań przeprowadzonych w 2009 r. w kolektorach kanalizacji sanitarnej miasta Chełm oraz porównano je z wartościami pomiarów wykonanych w roku 2008. W celu uwierzytelnienia otrzymanych wyników badania przeprowadzono dwoma niezależnymi metodami - metodą pływakową i dynamometryczną. Wykazano, iż wyznaczone prędkości przepływu ścieków w wybranych przewodach grawitacyjnej kanalizacji sanitarnej w Chełmie nie zapewniają ciągłego samooczyszczania z osadów ściekowych, pomimo że badane kanały zostały ułożone zgodnie z wytycznymi projektowania sieci kanalizacyjnej. W związku z powyższym kanał ulega zamuleniu, a zalegający osad niekorzystnie wpływa na warunki hydrauliczne w przewodzie, na co jednoznacznie wskazują powtarzane w ciągu ostatniego roku badania.
The assumptions of channel inclination, as well as constancy of cross section and roughness are close to reality. Accomplishment of these assumptions depends on pipes quality and conduits execution. The all mentioned elements influence the sewage flow mean velocity in gravitational sanitation systems and they are match to ensure hydraulic self purification of the conduits. Our research shows the real mean velocity of sewage flow after long lasting exploitation of the selected conduits. This paper presents also the results of research conducted in 2009 on sanitation system in Chelm city, as well as their comparison with results obtained one year earlier in these same conduits. In order of gained results validation the two methods of flow measurements were used - floating object and dynamometric. It was shown that existed velocities of sewage flow in chosen sanitation channels in Chelm, Poland, do not ensure the purification of the pipe - despite of the fact that examined channels fulfilling the binding guidelines. Consequently channel is silted and sediments are unfavorably influencing the hydraulic conditions of the flow, what is proven by conducted during last year researches.
Źródło:
Proceedings of ECOpole; 2012, 6, 2; 775-780
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu rodzaju materiału oraz czasu i sposobu eksploatacji kolektorów kanalizacji grawitacyjnej na prędkość przepływu ścieków
Influence of material, duration and exploitation manner of sanitation conduits on sewage flow velocity
Autorzy:
Jaromin, K.
Borkowski, T.
Łagód, G.
Widomski, M.
Powiązania:
https://bibliotekanauki.pl/articles/126034.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
przepływ bezciśnieniowy
samooczyszczanie kanałów
pomiar prędkości przepływu
gravitational flow
sewer self-purification
flow velocity measurement
Opis:
Podczas projektowania sieci kanalizacji sanitarnej założenie obliczeniowego spadku dna odcinka kanału, podobnie jak niezmienność przekroju oraz chropowatości, jest bliskie rzeczywistości. Spełnienie tego założenia zależy od jakości przewodów kanalizacyjnych oraz dokładności wykonania kanałów. Wszystkie wyżej wymienione elementy mają znaczący wpływ na średnie prędkości przepływu ścieków w kanalizacji grawitacyjnej i dobierane są w taki sposób, aby zapewnić samooczyszczanie kanału. Przeprowadzone badania pokazują rzeczywistą prędkość średnią przepływu ścieków po wieloletniej eksploatacji wybranych przewodów kanalizacyjnych. Zaprezentowano wyniki badań przeprowadzonych w 2008 r. w kolektorach kanalizacji sanitarnej miasta Chełm. W celu uwierzytelnienia otrzymanych wyników badania przeprowadzono dwiema niezależnymi metodami - metodą pływakową i dynamometryczną. Wykazano, iż wyznaczone prędkości przepływu ścieków w wybranych przewodach grawitacyjnej kanalizacji sanitarnej w Chełmie nie umożliwiają samooczyszczania z osadów ściekowych, pomimo że badane kanały zostały ułożone zgodnie z wytycznymi projektowania sieci kanalizacyjnej. W związku z powyższym kanał ulega zamuleniu, a zalegający osad niekorzystnie wpływa na warunki hydrauliczne w przewodzie.
The assumption of computational inclination of the channel, as well as constancy of cross-section and roughness are close to reality. Accomplishment of these assumptions depends to pipes quality and conduits execution. The all mentioned elements influence the sewage flow mean velocity in gravitational sanitation systems and they are selected to ensure self-purification of the conduits. Our research shows the real mean velocity of sewage flow after long lasting exploitation of the selected conduits. This paper presents the results of research conducted in 2008 on sanitation system in Chelm city, Poland. The studies cover the analysis of the influence of pipe material, duration and exploitation manner on the value of sewage mean velocity. In order of validation of the gained results two methods of flow measurements were used - floating object and dynamometric. It was shown that gained velocities of sewage flow in chosen sanitation channels in Chelm, do not render the purification of the pipe - despite the fact that studied channels are fulfilling the binding guidelines. Consequently, the channel is silted and sediments are unfavourably influencing the hydraulic conditions of the flow.
Źródło:
Proceedings of ECOpole; 2009, 3, 1; 139-145
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania opływu wybranych profili sond dla potrzeb w metrologii strumieni
Research of flow around selected sensors profiles for metrology flows
Autorzy:
Zgolak, P.
Powiązania:
https://bibliotekanauki.pl/articles/407725.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
kamera cyfrowa
pomiar przepływu płynu
pomiar prędkości
dynamika płynów
digital camera
fluid flow measurement
velocity measurement
fluid dynamics
Opis:
W pracy przedstawiono wyniki wizualizacji opływów wybranych profili sond spiętrzających przepływ. Określono częstotliwość odrywania się wirów za sondą. Przeprowadzono szereg badań eksperymentalnych mających na celu określenie oraz analizę zjawisk zachodzących w rozpatrywanym obszarze badawczym. Dzięki wykorzystaniu metody anemometrii obrazowej uzyskano rozkłady prędkości w otoczeniu badanych profili. Sformułowano wnioski natury metrologicznej.
The paper presents results of flow around visualization in selected sensors profiles of the pitot probe. Vortices detachment frequency from the probe was defined. A series of experimental research to identifying and determining analysis the phenomena occurring in the area of research were done. By using Practicle Image Velocimetry methods (PIV) velocity distribution around the analyzed profiles were obtained. Metrological type conclusions were formulated.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 4; 57-61
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania przepływu dwufazowego ciecz - ciało stałe w rurociągu pionowym metodami radioizotopowymi Cześć 1. Pomiar prędkości transportu ziaren fazy stałej
Radioisotope evaluation of two phase liquid-solid flow in a vertical pipe Part 1. Measurement of the velocity of solid particles
Autorzy:
Zych, M.
Petryka, L.
Hanus, R.
Powiązania:
https://bibliotekanauki.pl/articles/158444.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przepływ dwufazowy
hydrotransport
absorpcja promieniowania gamma
sygnały stochastyczne
korelacja wzajemna
two phase flow
vertical hydrotransport
gamma absorption method
stochastic signals
cross-correlation
Opis:
W artykule omówiono wykorzystanie izotopów promieniotwórczych do opisu unoszenia przez ciecz cząstek ciała stałego w rurociągu pionowym. Pokazano jak zastosowanie zestawu absorpcyjnego złożonego z dwóch źródeł promieniowania gamma 241Am i dwóch sond scyntylacyjnych umożliwia zarówno pomiar prędkości przepływu jak i koncentracji objętościowej fazy stałej. W prezentowanej metodzie średnia prędkość przepływu ziaren była wyznaczana przy zastosowaniu metody korelacji wzajemnej sygnałów rejestrowanych przez sondy. Dla ilustracji posłużono się pomiarami wykonami na potrzeby transportu hydraulicznego konkrecji polimetalicznych z dna Pacyfiku.
The paper presents an application of radioisotopes to description of transportation of solid particles by a liquid in a vertical pipe. It shows how the gamma absorption set, consisting of two radioactive isotopes 241Am and two scintillation probes, may be applied to measurements of both solid particles velocity and volumetric concentration of a flow. In this case the mean velocity of the solid phase transportation is evaluated by a cross-correlation of digital signals recorded by the probes. The paper is divided into five sections. The first is a short introduction to the subject of the paper. Section 2 presents the basis of solid particles velocity measurement by the gamma absorption method (Fig. 1, Eq. 1). Section 3 describes the laboratory installation (Fig. 2) which is an example of the transportation of ceramic models of pebbles expected during exploitation of polymetallic deposits from the Pacific. The diameter and concentration of solid particles were found to be variable and stochastically distributed in the stream. The cross-correlation analysis of the recorded signals (Eq. 2, Fig. 4) and the uncertainty evaluation of the mean velocity (Eq. 3) are given in Section 4. The uncertainty of the mean velocity of the solid particles is reduced to 1%. Section 5 summarises the results and presents final remarks. The authors conclude that the method described in this paper can be applied to many similar complex streams transported through pipelines.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 4, 4; 315-317
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Error of average velocity flow measurement in ventilation system channels
Pogreshnost izmereniya sredney skorosti potoka v kanalakh ventilyatsionníkh sistem
Autorzy:
Gusentsova, E.
Kovalenko, A.
Pilavov, M.
Powiązania:
https://bibliotekanauki.pl/articles/793050.pdf
Data publikacji:
2011
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2011, 11A
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental research on velocity profiles in selected flow systems
Autorzy:
Kabaciński, M.
Powiązania:
https://bibliotekanauki.pl/articles/1933977.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska
Tematy:
velocity profiles
air flow measurement
closed conduits
automated test stand
differential pressure flowmeter
Opis:
A problem of measuring of velocity profiles with the use of a fully automated test stand is presented in this paper. Due to the installed measurement equipment and various software alternatives it is possible to assess the inlet effect and distribution of velocities in the vicinity of averaging Pitot tubes in order to determine the phenomena occurring in their vicinity (recirculation, main stream direction) and verify the numerical models of turbulence. Due to the stream recirculation in the vicinity of the probes tested in a wind tunnel, a two-way probe was used instead of a Pitot tube. A linear module with a stepper motor formed an integral part of the measurement system whereby it was possible to determine the position of the measurement probe with a precision of 0.1mm. The measuring anemometer location, the possibility of adjusting the stream mean velocities and data acquisition were established by means of an original program. As far as the research in pipelines is concerned - the resulting characteristics allow the uncertainty of measurement to be precisely determined, which should be accounted for during the determination of air fluxes at locations which are not included in the technical documentation of a flowmeter.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2012, 16, 3-4; 185-201
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flow averaging tube geometry improvement for K-factor stability increase
Autorzy:
Kabaciński, M.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/114099.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
velocity profiles
air flow measurement
closed conduits
automated test stand
flow averaging Pitot tube
Opis:
Fluid flow around two-profile averaging differential pressure sensor was investigated in this paper. Research concentrated particularly on fluid movement direction and velocity over the investigated flow sensor. Analysis was conducted experimentally in low velocity wind tunnel. Because of large number of measuring points placed very close to each other, it was decided that velocity profile measurement will be performed by means of fully automated test stand. Due to a recirculation of the stream in the vicinity of the probe tested in the wind tunnel, an original two-direction probe was used. A linear module with a stepper motor formed an integral part of the measurement system. The location of the measuring probe, the possibility of adjusting stream mean velocities and data acquisition was undertaken by means of a dedicated program. The above mentioned investigation method helped to improve the metrological properties of the flowmeter applying non symmetrical probe cross-section forced air stream to be redirected in the desired direction. This modification significantly increased K-factor value and stability of air flow through the contraction of the flowmeter.
Źródło:
Measurement Automation Monitoring; 2017, 63, 1; 2-5
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flow velocity measurement methods using electrical capacitance tomography
Metody pomiaru prędkości przepływu z zastosowaniem tomografii pojemnościowej
Autorzy:
Mosorov, V.
Grudzień, K.
Sankowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/407966.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
electrical capacitance tomography
velocity profile
statistical method
elektryczna tomografia pojemnościowa
profil prędkości
metoda statystyczna
Opis:
The current methods of calculating the velocity field based on a twin-plane electrical capacitance system for multiphase flows are presented. The described methods allow to calculate the velocity profile of the multiphase flow in cross-section of industrial installation. The theoretical assumptions of the considered methods are also noticed. The main advantages and disadvantages of the authors’ flow velocity measurement methods are discussed.
Artykuł przedstawia przegląd metod wyznaczania prędkości przepływu w oparciu o dwupłaszczowy system pojemnościowej tomografii procesowej. Zaprezentowane metody pozwalają na obliczenie profilu prędkości wielofazowych przepływów w przekroju poprzecznym instalacji przemysłowej. Przeprowadzono także dyskusję nad teoretycznymi założeniami omawianych metod oraz opisano główne zalety i wady autorskich metod pomiaru prędkości przepływów wielofazowych.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 1; 30-36
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implementacja metod znaczników termicznych w pomiarach prędkości przepływu gazów w aerologii górniczej
Implementation of thermal markers methods in measurements of gas flow velocity in mining aerology
Autorzy:
Ligęza, P.
Powiązania:
https://bibliotekanauki.pl/articles/164625.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
aerologia górnicza
pomiar małych prędkości
metody pomiarowe
znaczniki termiczne
pomiary wzorcowe
mining aerology
low velocity measurement
measurement methods
thermal markers
standard measurements
Opis:
Jednym z ważnych problemów aerologii górniczej jest pomiar bardzo małych prędkości przepływu powietrza i innych gazów. Jedną z metod jest metoda znaczników termicznych, polegająca na wywołaniu w przepływie fluktuacji temperatury i pomiarze prędkości ich propagacji. W artykule poddano analizie problem implementacji metod znaczników termicznych w pomiarach prędkości przepływu gazów w aerologii górniczej. Obszar zastosowań tych metod dotyczy pomiarów wzorcowych, specjalistycznych pomiarów wentylacyjnych, badań laboratoryjnych i modelowych, a także potencjalnego zastosowania metod w przenośnych przyrządach pomiarowych. Metody znaczników termicznych umożliwią bezwzględny pomiar bardzo małych prędkości przepływu powietrza i innych gazów, nie wymagają wzorcowania, są mało wrażliwe na zmiany temperatury, ciśnienia, składu czy wilgotności medium.
One of the important problems of mining aerology is the measurement of very low flow velocity of air and other gases. One of the applicable methods is the method of thermal markers, which consist in analyzing the temperature fluctuations propagation in flow. In this paper we analyzed the problem of implementation thermal markers methods for measuring in mining aerology. Areas of application of these methods are standard and specialized ventilation measurements, laboratory and model tests, and the potential application in portable measuring instruments. Methods of thermal markers allow for absolute measurement of very low flow velocity range, do not require calibration and are not very sensitive to changes in temperature, pressure or humidity.
Źródło:
Przegląd Górniczy; 2015, 71, 11; 95-100
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of disturbed flow after an elbow on metrological properties of a Flow Averaging Tube
Autorzy:
Kabaciński, M.
Powiązania:
https://bibliotekanauki.pl/articles/114498.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
velocity profile measurement system
averaging Pitot tube
Flow Averaging Tube K-factor
elbow flow
automated test stand
Opis:
Experimental results of air velocity profiles and Flow Averaging Tubes (FAT®) K-factor measured behind an elbow are presented in this paper. The pipeline diameter was D=150 mm, while the range of mean velocities w=9…30 m/s. Velocity profiles were determined both in the vertical and horizontal plane in the respective distances L/D of a pipeline from 3 to 18. In the places of the measured velocity profiles, three cross-sections of flow averaging tubes (circular, streamlined and two-profile) were placed to determine the characteristics of K-factor. Moreover, a fully automated test stand is presented in this paper. The completed experiment allows shortening the distance between an elbow and a flowmeter installation place and informing about the value of a correction factor, which can be used to minimize the measurement uncertainty of the air flow rate. It was stated that the horizontal plane is better to install a probe because of the velocity profile and better results of repeatability.
Źródło:
Measurement Automation Monitoring; 2016, 62, 1; 7-16
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interpretacja wyników pomiaru prędkości przepływu ładunku w komorze spalania tłokowego silnika spalinowego
: Interpretation of measurement results of flow velocity in the ICE combustion chamber
Autorzy:
Tutak, W.
Powiązania:
https://bibliotekanauki.pl/articles/151180.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar
pole prędkości
komora spalania
measur
flow field
combustion chamber
Opis:
W opracowaniu przedstawiono interpretację wyników pomiaru prędkości przepływu ładunku w komorze spalania tłokowego silnika spalinowego. Analizie poddano wpływ metody opracowania wyników pomiaru prędkości przepływu na uzyskane wyniki parametrów opisu pola prędkości w komorze spalania silnika tłokowego.
The paper presents measurement results of flow field of fresh charge in the combustion chamber of the internal combustion engine. Possibilities of interpretation results of flow velocity measurement in combustion chamber of internal combustion engine are presented in the paper. The data handling method of flow velocity measurement result influence on obtained turbulence field in combustion chamber parameters are analyzed. The results of research show that non-repeatability of flow velocity in the combustion chamber have influence on description of turbulence parameters.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 2, 2; 67-70
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikroprocesorowy anemometr z zanikającym sygnałem ultradźwiękowym
Microprocessor-based anemometer with fading ultrasonic signal
Autorzy:
Biernacki, Z.
Borowik, L.
Rakus, P.
Powiązania:
https://bibliotekanauki.pl/articles/158331.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary prędkości przepływów
przetworniki ultradźwiękowe
anemometr
przepływ
measurement of flow velocity
ultrasonic transducers
anemometer
flow
Opis:
W artykule zaprezentowano anemometr ultradźwiękowy, którego działanie polega na pomiarze częstotliwości cykli "nadawanie-odbiór" sygnału pomiędzy nadajnikiem a odbiornikiem zgodnie lub przeciwnie do kierunku przepływu. Informacja o przepływie dla takiego rozwiązania, zawarta jest w różnicy częstotliwości powtarzania się tych cykli w zależności od prędkości i kierunku przepływu. Algorytm pomiarowy realizowany jest w układzie wykonanym w oparciu o mikroprocesor AT89C2051. Zastosowanie mikroprocesora do jednoczesnego sterowania nadajnikiem i odbiornikiem ułatwia synchronizację sygnałów co ma wpływ na poprawienie dokładności pomiarów. Zaproponowane rozwiązanie może być stosowane zarówno do pomiaru prędkości przepływu mediów gazowych jak i cieczy o zróżnicowanym składzie chemicznym czy stężeniu dzięki możliwości uniezależnienia wyniku od prędkości dźwięku, która jest charakterystyczna dla danego ośrodka w określonych warunkach. Przedstawiono również wybrane wyniki pomiarów prędkości przepływu powietrza przy użyciu takiego anemometru dla ustalonej prędkości mierzonej anemometrem kontrolnym w osi tunelu.
The paper presents an ultrasonic anemometer whose principle of working is based on measurements of the frequency of "transmission - reception" cycles of an ultrasonic signal between the transmitter and receiver with or against the flow direction. Information about the flow velocity is contained in the frequency of these cycles which depends on the value of velocity and its direction. The measuring system uses a simple microprocessor AT89C2051 which controls the work of a transmitter and receiver set. The chosen results of measurements of the air velocity with this anemometer are presented. The suggested solution can be applied to measurements of the flow speed of gas as well as liquid of all kinds of chemical composition or concentration thanks to the possibility of obtaining results independent of the sound speed characteristic for the given medium under determined conditions. There are also given the measurement results of the air flow speed taken with this anemometer for the established speed measured with the testing anemometer in the tunnel axis.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 10, 10; 1234-1237
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies