Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "exposure dose" wg kryterium: Wszystkie pola


Tytuł:
Analysis of dose distribution around a computed tomography scanner in terms of exposure to scattered ionizing radiation of caregivers of pediatric patients
Autorzy:
Biegała, Michał
Brodecki, Marcin
Skoczylas, Krystian
Jakubowska, Teresa
Domienik-Andrzejewska, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/45912311.pdf
Data publikacji:
2024-09-10
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
effective dose
radiological protection
leukemia
CT scanner
probability of induction of leukemia
pediatric radiology
Opis:
Objectives During computed tomography (CT), a large amount of ionizing radiation is emitted to ensure high quality of the obtained radiological image. This study measured the dose distribution around the CT scanner and the exposure of people staying near the CT scanner during the examination. Material and Methods The measurements used an anthropomorphic phantom to assess human exposure to ionizing radiation. The probability of inducing leukemia and other cancers as a result of absorbing doses recorded around the CT device was also calculated. Results The highest exposure to scattered radiation in the proximity of the CT scanner is recorded at the gantry of the tomograph, i.e., 55.7 μGy, and the lowest, below lower detection limit of 6 μGy at the end of the diagnostic table. The whole-body detector placed on the anthropomorphic phantom located at the diagnostic table right next to the CT gantry recorded 59.5 μSv and at the end of the table 1.5 μSv. The average doses to the lenses in these locations were: 32.1 μSv and 2.9 μSv, respectively. Conclusions The probability of induction of leukemia or other types of cancer is low, but the need for people to stay in the examination room during a CT examination should be limited to the necessary minimum.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2024, 37, 3; 326-334
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of annual exposure of private farmers to whole body mechanical vibration on selected family farms of plant production profile
Autorzy:
Solecki, L
Powiązania:
https://bibliotekanauki.pl/articles/51452.pdf
Data publikacji:
2010
Wydawca:
Instytut Medycyny Wsi
Tematy:
occupational exposure
agriculture
occupational disease
human disease
family farm
plant production
private farmer
farmer exposure
annual exposure
whole body vibration
mechanical vibration
daily exposure
vibration dose
vibration acceleration
noise
Źródło:
Annals of Agricultural and Environmental Medicine; 2010, 17, 2; 243-250
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of exposure of workers to ionizing radiation from radioiodine and technetium in nuclear medicine departmental facilities
Ocena narażenia pracowników na promieniowanie jonizujące radiojodu i technetu w zakładach medycyny nuklearnej
Autorzy:
Krajewska, Grażyna
Pachocki, Krzysztof A.
Powiązania:
https://bibliotekanauki.pl/articles/2166302.pdf
Data publikacji:
2014-11-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
radiojod 131I
technet 99mTc
medycyna nuklearna
dawka skuteczna
ekspozycja zawodowa
radioiodine 131I
technetium 99mTc
nuclear medicine
effective dose
occupational exposure
Opis:
Background: Due to its use of ionising radiation, the field of nuclear medicine is a unique and significant part of medical diagnostics and patient treatment. The aim of this study was to assess the internal exposure of nuclear medicine employees to radioiodine 131I and technetium 99mTc as well as to assess the external exposure doses. Material and Methods: The radioiodine 131I and technetium 99mTc contents in the thyroid of staff members (about 100 persons) dealing with these radionuclides have been measured in four departments of nuclear medicine. The measurements were conducted with a portable detection unit for in situ measurements of radioiodine and technetium. High sensitivity environmental thermoluminescent dosimeters (TLD) were used to measure the external exposure dose. Results: The average values and ranges of radioiodine 131I activity measured in the thyroids of all of the medical units' employees were: 83 Bq (range: 70-250 Bq), 280 Bq (range: 70-4000 Bq), 275 Bq (range: 70-1000 Bq) for technical staff, nuclear medicine staff and hospital services staff, respectively. The mean value of technetium 99mTc content in the thyroids of nuclear medicine staff was approximately 1500 Bq (range: 50- -1800 Bq). External exposure dose rates were in the range of 0.5-10 μGy/h. Conclusions: The calculated average effective dose for particular person caused by the inhalation of radioiodine 131I is below 5% of 20 mSv/year (occupational exposure limit). Med Pr 2013;64(5):625–630
Wprowadzenie: Ze względu na stosowanie promieniowania jonizującego medycyna nuklearna jest istotną i unikalną gałęzią metod diagnostycznych i leczniczych. Celem podjętych badań była ocena narażenia wewnętrznego pracowników zakładów medycyny nuklearnej na jod promieniotwórczy 131I i technet 99mTc oraz ocena dawek pochodzących z ekspozycji zewnętrznej. Materiał i metody: Pomiary zawartości radiojodu 131I i technetu 99mTc w tarczycy osób pracujących z tymi radionuklidami (ok. 100 osób) wykonano w 4 ośrodkach medycyny nuklearnej. Zastosowano przenośny zestaw detekcyjny mierzący radionuklidy in situ. Dawki pochodzące z ekspozycji zewnętrznej mierzono, wykorzystując środowiskowe dozymetry termoluminescencyjne (thermoluminescent dosimeters - TLD) o dużej czułości. Wyniki: Zawartość radiojodu 131I w tarczycy wynosiła średnio: 83 Bq (zakres aktywności: 70-250 Bq) w grupie personelu technicznego, 280 Bq (zakres: 70-4000 Bq) w grupie personelu medycznego i 275 Bq (zakres: 70-1000 Bq) w grupie personelu pomocniczego. Średnia zawartość technetu 99mTc w tarczycy wynosiła ok. 1500 Bq (zakres: 50-1800 Bq). Otrzymana moc dawek pochodzących z ekspozycji zewnętrznej mieściła się w zakresie 0,5-10 μGy/godz. Wnioski: Oszacowana średnia dawka skuteczna pochodząca z inhalacji radiojodu 131I stanowiła mniej niż 5% rocznego limitu dla narażenia zawodowego, które wynosi 20 mSv/rok. Med. Pr. 2013;64(5):625–630
Źródło:
Medycyna Pracy; 2013, 64, 5; 625-630
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Authors’ response (December 8, 2017) to the letter to the Editor concerning the paper “Occupational exposure to radon for underground tourist routes in Poland: Doses to lung and the risk of developing lung cancer”
Autorzy:
Walczak, Katarzyna
Olszewski, Jerzy
Politański, Piotr
Zmyślony, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2162023.pdf
Data publikacji:
2018-10-24
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
radon
cancer risk
LNT model
hormesis
radiation risk model
low dose ionizing radiation
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2018, 31, 5; 707-709
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czy opatrunek gipsowy wpływa na indeks ekspozycji i dose area product? : Odpowiedź na przykładzie radiografii nadgarstka
Are the plaster cast have influence on exposure index and dose area product value? : Based on the wrist radiography
Autorzy:
Nowak, P.
Murzyn, K.
Pasieka, E.
Powiązania:
https://bibliotekanauki.pl/articles/112147.pdf
Data publikacji:
2018
Wydawca:
Indygo Zahir Media
Tematy:
indeks ekspozycji
nadgarstek
zdjęcie rentgenowskie
opatrunek gipsowy
dose area product
exposure index, wrist
radiography
plaster cast
Opis:
Złamania dystalnej części kości promieniowej należą do jednych z najczęstszych urazów kości. W przypadku tego typu urazów podstawnym badaniem obrazowym, ze względu na niski koszt wykonania i ogólną dostępność, jest zdjęcie rentgenowskie. Standardowo radiografię stawu nadgarstkowego wykonuje się w projekcji: tylno-przedniej, skośnej i bocznej. Dodatkowymi badaniami są radiogramy w odchyleniu promieniowym lub łokciowym, a także zdjęcie celowane na kanał nadgarstka oraz kość łódeczkowatą. Cel: Celem pracy była retrospektywna analiza wartości dose area product i indeksu ekspozycji podczas radiografii stawu nadgarstkowego u pacjentów z zastosowanym opatrunkiem gipsowym oraz bez, w zależności od wielkości pola kolimacji rentgenogramu, a także wykorzystanych do diagnostyki parametrów ekspozycji. Materiały i metody: Analizie retrospektywnej poddano 208 losowo wybranych radiogramów stawu nadgarstkowego wykonanych w Zakładzie Radiologii Uniwersyteckiego Szpitala Klinicznego w Białymstoku aparatem RTG Axiom Aristos firmy Siemens. Badanie obejmowało wartości dose area product i indeksu ekspozycji, napięcia anodowego, obciążenia prądowo-czasowego oraz wiel¬kości pól kolimacji. Zebrane dane poddano analizie statystycznej przy użyciu programu Statistica 12,5 oraz MS Excel 2013. Wyniki: Większą część osób, którym wykonano radiogramy, sta¬nowiły kobiety. W tej grupie średnia wieku wyniosła 63,79 lat, natomiast średnia wieku mężczyzn była równa 47,56 lat. Średnia wielkość pola kolimacji rentgenogramu z grupy objętej bada¬niem wyniosła 324,17 cm2. Przy założeniu, że wartość referen¬cyjna pola kolimacji wynosi 234 cm2 (13 x 18 cm), to 160 (72,92%) zdjęć miało pole kolimacji większe od wartości referencyjnej, natomiast przy przyjęciu 432 cm2 (18 x 24 cm) jako wartość odniesienia tylko 35 (16,83%) radiogramów było większych od wartości wzorcowej. Wartość współczynnika ekspozycji wynio¬sła średnio 645,87 z wartością maksymalną równą 2980,00, na¬tomiast najniższa wartość była równa 141,00. Średnia wartość DAP w grupie objętej badaniem wyniosła 0,02 Gy∙cm2, przy od¬chyleniu standardowym 0,01 Gy∙cm2. Największa odnotowana wartość współczynnika DAP wyniosła 0,07 Gy∙cm2, natomiast najmniejsza 0,01 Gy∙cm2. Testy statystyczne wykazały korelację między polem powierzchni a DAP na poziomie rs = 0,78 i polem powierzchni a EXI rs = 0,19 oraz między wartością DAP (p = 0,00) i EXI (p = 0,00) a obecnością opatrunku gipsowego. Wnioski: W radiografii cyfrowej bezpośredniej (system Siemens) opatrunek gipsowy wpływa w istotny sposób na wartości DAP, zwiększając go średnio o 0,01 Gy∙cm2 oraz EXI, zmniejszając jego wartość niemal o połowę. Także zwiększenie pola kolimacji po¬woduje zwiększenie wartości DAP i EXI w radiografii nadgarstka.
Distal part radial bone fractures are one of the most common types of trauma. The basis of imaging examination of the injury is radiography. The advantages of the X-ray examination are low costs and widespread availability. Standard projections for the wrist are posteroanterior and lateral views. However, there are many ancillary views like a radiograms obtained with radial or ulnar deviation and carpal tunel. Aim: The aim of the study is retrospective analysis of dose area product and exposure index during radiography of the wrist. The analysis included value collimation size and exposure para¬meters depending on whether plaster immobilization was used or not. Materials and methods: We conduct retrospective analysis of randomly selected 208 radiographs of the wrist. X-ray photos were taken of patients at the Department of Radiology, Medi¬cal University Hospital in Bialystok, with Axiom Aristos Siemens. The analysis included value of the dose area product, exposure index, tube potential, tube current-time product and collima¬tion field. Statistical analysis was done using Statistica 12.5 and MS Excel 2013. Results: The most frequently radiographs were taken for wo¬men which average age was 63,79 while average age for men was 47,56. The average size of X-ray was 324,17 cm2. Assuming that the reference value of the collimation field is 234 cm2 (160x160), 160 (72.92%) images had collimation field greater than reference value. On the other hand when reference va¬lue is 432 cm2 (18 x 24 cm) only 35 (16.83%) of the radiographs were greater. The average exposure index value was 645,87, while the maximum value was 2980,00 and minimum value was 141,00. The average DAP in study group was 0,02 Gy∙cm2, SD = 0,01 Gy∙cm2. The largest recorded DAP was 0,07 Gy∙cm2, while the smallest was 0,01 Gy∙cm2. Statistic tests showed a signifi¬cant dependence between collimation field size value and DAP (rs = 0 ,78), c ollimation fi eld s ize v alue a nd E XI ( rs = 0 ,19); D AP (p = 0,00) and EXI (p = 0,00), and presence of plaster cast. Conclusions: In digital radiology (Siemens), plaster cast have a si¬gnificant influence on DAP, increasing it 0,01 Gy∙cm2 on average and EXI reduced its value almost by half. The increased surface area of the radiographs causes increased DAP and EXI.
Źródło:
Inżynier i Fizyk Medyczny; 2018, 7, 2; 85-91
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dense Plasma Focus as a powerful source of monochromatic X-ray radiation
Autorzy:
Dubrovsky, A.
Gribkov, V.
Ivanov, Y.
Karpiński, L.
Orlova, M.
Powiązania:
https://bibliotekanauki.pl/articles/147444.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dense plasma focus (DPF)
X-ray generation
X-ray dosimetry
exposure dose
absorbed dose
Opis:
A review of some experimental results obtained using the dense plasma focus (DPF) device PF-1000 is presented. The copper Ka1,2 radiation line generated by DPF in the case of device anode made of copper was the main object of this study. The predominance of this characteristic radiation over other kinds of radiation in the DPF X-ray spectrum is shown. A brief description of a new DPF 6.0 device as well as a radioenzymology experiment carried out within this device is presented.
Źródło:
Nukleonika; 2006, 51, 1; 21-28
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Does occupational exposure to low ionizing radiation affect endothelium health?
Autorzy:
Al-Massarani, G.
Najjar, F.
Powiązania:
https://bibliotekanauki.pl/articles/147716.pdf
Data publikacji:
2013
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
circulating endothelial cells (CEC)
occupational exposure
low-dose ionizing radiation
Opis:
The aim of this study was to assess the effect of low-radiation exposure on detachment of the vascular endothelial cells. Circulating endothelial cells (CEC) were measured in the peripheral blood by an immunomagnetic separation (IMS) technique in 63 workers occupationally exposed to low-level ionizing radiation at the Atomic Energy Commission of Syria and in 28 controls. We found a significant difference in CEC numbers in the peripheral blood of the workers exposed to low-level ionizing radiation in comparison with those of the control samples (p = 0.0001) and no significant difference in the proportion of other blood elements in the peripheral circulation. Elevated number of CEC in occupational workers exposed to low doses of ionizing radiation may reflect an early affection of the endothelium. Long-term follow-up of these workers must be conducted to determine the clinical value of CEC as an early indicator of cardiovascular disease induced as a result of chronic occupational exposure to low doses of ionizing radiation.
Źródło:
Nukleonika; 2013, 58, 4; 527-531
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dose-dependent relationship between prenatal exposure to fine particulates and exhaled carbon monoxide in non-asthmatic children. A population-based birth cohort study
Autorzy:
Jędrychowski, Wiesław A.
Maugeri, Umberto
Spengler, John
Mróz, Elżbieta
Flak, Elżbieta
Klimaszewska-Rembiasz, Maria
Jacek, Ryszard
Sowa, Agata
Powiązania:
https://bibliotekanauki.pl/articles/2179792.pdf
Data publikacji:
2013-03-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
exhaled CO
prenatal exposure
fine particulate matter
healthy non-asthmatic children
Opis:
Objectives: The main goal of the study was to assess possible association between fetal exposure to fi ne particulate matter ($\text{PM}_\text{2.5}$) and exhaled carbon monoxide (eCO) measured in non-asthmatic children. Material and Methods: The subjects include 118 children taking part in an ongoing population-based birth cohort study in Kraków. Personal samplers of $\text{PM}_\text{2.5}$ were used to measure fi ne particle mass in the fetal period and carbon monoxide (CO) in exhaled breath from a single exhalation effort at the age of 7. In the statistical analysis of the effect of prenatal $\text{PM}_\text{2.5}$ exposure on eCO, a set of potential confounders, such as environmental tobacco smoke (ETS), city residence area, sensitization to house dust allergens and the occurrence of respiratory symptoms monitored over the seven-year follow-up was considered. Results: The level of eCO did not correlate with the self-reported ETS exposure recorded over the follow-up, however, there was a positive signifi cant relationship with the prenatal $\text{PM}_\text{2.5}$ exposure (non-parametric trend p = 0.042). The eCO mean level was higher in atopic children (geometric mean = 2.06 ppm, 95% CI: 1.58–2.66 ppm) than in non-atopic ones (geometric mean = 1.57 ppm, 95% CI: 1.47–1.73 ppm) and the difference was statistically signifi cant (p = 0.036). As for the respiratory symptoms, eCO values were associated positively only with the cough severity score recorded in the follow-up (nonparametric trend p = 0.057). In the nested multivariable linear regression model, only the effects of prenatal $\text{PM}_\text{2.5}$ and cough severity recorded in the follow-up were related to eCO level. The prenatal $\text{PM}_\text{2.5}$ exposure represented 5.1%, while children’s cough represented only 2.6% of the eCO variability. Conclusion: Our study suggests that elevated eCO in non-asthmatic children may result from oxidative stress experienced in the fetal period and that heme oxygenase (HO) activity in body tissues may be programmed in the fetal period by the exposure to fi ne particulate matter.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2013, 26, 1; 73-82
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Drgania i hałas na stanowiskach pracy w środkach komunikacji miejskiej - badania dozymetryczne
Evaluation of noise and vibration exposure at workplaces in city transportation using noise and vibration dose meters
Autorzy:
Koton, J.
Majewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/179181.pdf
Data publikacji:
2004
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
hałas
hałas na stanowisku pracy
hałas komunikacyjny
noise
traffic noise
Opis:
Z doniesień literaturowych, zwłaszcza ostatniego dziesięciolecia, wynika, że skojarzone działanie na organizm człowieka dwóch lub więcej szkodliwych i uciążliwych czynników środowiska pracy potęguje niekorzystne skutki działania każdego z nich występującego oddzielnie. Do stanowisk pracy, na których występują łącznie różne czynniki środowiska, należą niewątpliwie stanowiska obsługi wszelkiego rodzaju pojazdów, w tym pojazdów komunikacji miejskiej. W artykule przedstawiono wyniki badań jednoczesnej ekspozycji kierowców na drgania i hałas w autobusach miejskich, tramwajach i w metrze. Uzyskane wyniki porównano z wartościami kryterialnymi ustalonymi dla tych czynników ze względu na ochronę zdrowia w przepisach krajowych i w dyrektywach Unii Europejskiej.
Drivers of city transportation are exposed to noise and vibration, among others, which may affect health, comfort and perception. In order to evaluate occupational exposure and to assess the risk arising from those two agents, measurements were carried out in Warsaw city buses, trams and metro. Daily exposure to noise and vibration was measured simultaneously, throughout the working day, using noise and vibration dose meters. The results of the measurements as well as a comparison of work conditions in specific kinds of city transportation are presented and discussed in this paper. Moreover, the obtained daily exposure to noise and vibration is compared with the requirements of Polish law and the safety requirements of Directive 2002/44/EC (vibration) and Directive 2003/10/EC (noise).
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2004, 7/8; 12-15
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure to ionizing radiation by service personnel working with cyclotrons used to produce radiopharmaceuticals in PET diagnostics
Autorzy:
Biegała, Michał
Jakubowska, Teresa
Wrzesień, Małgorzata
Albiniak, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2152980.pdf
Data publikacji:
2022
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
nuclear medicine
PET
equivalent dose
service
radiological protection
cyclotron
Opis:
Objectives While working with cyclotrons used for the production of radiopharmaceuticals, workers can experience significant exposure to the adverse effects of ionizing radiation. The aim of this paper was to determine the typical level of such exposure received by such personnel while servicing cyclotrons. Material and Methods Exposure was assessed using TLD detectors placed in an anthropomorphic phantom, as well as dose meter to determine whole body and eye lens exposure. The phantom was placed in locations receiving the greatest exposure to ionizing radiation during service activities. The time spent by employees during servicing was assessed based on routine visits by service technicians. The obtained results were compared with readings of detectors worn by employees during service activities. Results The highest equivalent doses in the thoracic area were found to be received by the lungs (211.16 μSv/year). In the head and neck area, the highest dose was measured in the eye lens (3410 μSv/year). The effective dose for the whole body was found to be 1154.4 μSv/year, based on the phantom, and 149 μSv per service visit (1192 μSv/year), based on the dose meters carried by the workers. Conclusions Service workers are exposed to significant doses of ionizing radiation, representing a clear radiological protection issue. To reduce exposure to eye lenses, it is recommended to use protective goggles when working with highly-radioactive elements.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2022, 35, 6; 753-760
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Expression of cellular isoform of prion protein on the surface of peripheral blood lymphocytes among women exposed to low doses of ionizing radiation
Autorzy:
Klucinski, P
Mazur, B.
Hrycek, A.
Masluch, E.
Cieslik, P.
Kaufman, J.
Martirosian, G.
Powiązania:
https://bibliotekanauki.pl/articles/50336.pdf
Data publikacji:
2007
Wydawca:
Instytut Medycyny Wsi
Tematy:
blood lymphocyte
ionizing radiation
low dose
lymphocyte
cellular isoform
woman
radiation exposure
expression
prion protein
Opis:
Ionizing radiation affects the expression of adhesive and co-stimulatory molecules in lymphocytes. The physiological function of cellular isoform of prion protein (PrPc) is little known. Evidences indicate a link between lymphocytes activation and PrPc expression on their surface; however, no direct effect of radiation on PrPc level in these cells was investigated. The objective of this study was to determinate the effect of low doses of ionizing radiation on the expression of PrPc on the surface peripheral blood lymphocytes in the women operating X-ray equipment. In 36 female workers and 30 persons of the control group the PrPc expression on CD3 (T lymphocytes), CD4 (T helper), CD8 (T cytotoxic) and CD19 (B lymphocytes), as well as the percentage of lymphocytes with PrPc on their surface, were tested. Subgroups with respect to age and length of employment were selected. A signifi cant increase was observed in PrPc expression on CD3 and CD4 with lowered PrPc level on CD8 and percentage of CD8 cells with PrPc in workers compared to control. The PrPc level did not show signifi cant changes in subgroups in relation to age (below and over 40 years old) both in the investigated and control groups, whereas a lower percentage of PrPc expressing CD19 cells showed in employed women below 40 years of age. A signifi cant decrease was found in PrPc expression on the surface of CD3, CD4 and CD8 cells in the subgroup employed for over 10 years than in the subgroup with less than 10 years of employment.
Źródło:
Annals of Agricultural and Environmental Medicine; 2007, 14, 2
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of variable magnetic field stimulation on growth of aboveground parts of potato plants
Autorzy:
Marks, N.
Szecowka, P.S.
Powiązania:
https://bibliotekanauki.pl/articles/24275.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
potato plant
potato tuber
field stimulation
magnetic field
magnetic induction
exposure dose
growth
stem mass
leaf mass
aboveground part
Źródło:
International Agrophysics; 2010, 24, 2; 165-170
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Infl uence of an Increased Controlled Dose of Irradiance on the Change of Selected Physicochemical Properties of Paint Systems Used in Rolling Stock
Autorzy:
Garbacz, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2203230.pdf
Data publikacji:
2022
Wydawca:
Instytut Kolejnictwa
Tematy:
accelerated weathering
xenon-arc radiation
paint coatings
irradiance
radiant exposure
hardness
gloss
colour
rolling stock
Opis:
The article presents the results of ageing tests with the use of laboratory light radiation tested according to the EN ISO 16474-2 standard for painting systems used in rolling stock. Th e influence of aging on such properties as gloss, colour and hardness, was determined using two different irradiance settings of the order of 60 W/m2 and 120 W/m2 for the wavelength 300÷400 nm and the same levels of radiant exposure. In addition, this study describes the most important information about laboratory aging tests with simulation of sunlight, temperature, moisture including rain, which are included in ISO standardised test methods. The influence of weather parameters has been described, in particular the influence of an increased dose of irradiance on the degradation of selected physicochemical properties of coatings and the possibility of the predicted ageing progress (changes in selected properties). The obtained results of laboratory tests allow to make certain assumptions regarding the increase of the dose of irradiance and thus the shortening of the laboratory testing time in the context of the assessment of the most desirable properties of the coating for a given application with the use of laboratory ageing tests.
Źródło:
Problemy Kolejnictwa; 2022, 197; 99--115
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of pre-sowing magnetic biostimulation on germination and yield of wheat
Autorzy:
Pietruszewski, S.
Powiązania:
https://bibliotekanauki.pl/articles/24995.pdf
Data publikacji:
1999
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
wheat
Jara cultivar
wheat cultivar
yield
Henika cultivar
magnetic biostimulation
magnetic exposure dose
germination
Źródło:
International Agrophysics; 1999, 13, 2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of Radiation Exposure Dose from Nuclear Medicine Procedures (Tc-99m MAG-3)
Autorzy:
Kara, U.
Yildiz, M.
Akkurt, I.
Powiązania:
https://bibliotekanauki.pl/articles/1031923.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.50.yk
87.57.uk
Opis:
Nuclear medicine is great for viewing the roles of body organs. Medical imaging in nuclear medicine takes radioactive pharmaceuticals and studies their path of progress through patient's body. The principles of nuclear medicine are different from those of diagnostic radiology. The nuclear medicine can study the functioning of body and how it actually works. On the other hand, usage of different kinds of radiopharmaceuticals in nuclear medicine examinations can affect the dose rates. The purpose of our investigation was to estimate the effective dose from most common procedures, performed in nuclear medicine departments. We noted the injection radiation doses, which are used for diagnosis in nuclear medicine clinics. Later patient radiation doses were calculated, according to models recommended in ICRP 106.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 883-885
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies