Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "exposure dose" wg kryterium: Wszystkie pola


Tytuł:
Investigation of Radiation Exposure Dose from Nuclear Medicine Procedures (Tc-99m MAG-3)
Autorzy:
Kara, U.
Yildiz, M.
Akkurt, I.
Powiązania:
https://bibliotekanauki.pl/articles/1031923.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.50.yk
87.57.uk
Opis:
Nuclear medicine is great for viewing the roles of body organs. Medical imaging in nuclear medicine takes radioactive pharmaceuticals and studies their path of progress through patient's body. The principles of nuclear medicine are different from those of diagnostic radiology. The nuclear medicine can study the functioning of body and how it actually works. On the other hand, usage of different kinds of radiopharmaceuticals in nuclear medicine examinations can affect the dose rates. The purpose of our investigation was to estimate the effective dose from most common procedures, performed in nuclear medicine departments. We noted the injection radiation doses, which are used for diagnosis in nuclear medicine clinics. Later patient radiation doses were calculated, according to models recommended in ICRP 106.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 883-885
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dense Plasma Focus as a powerful source of monochromatic X-ray radiation
Autorzy:
Dubrovsky, A.
Gribkov, V.
Ivanov, Y.
Karpiński, L.
Orlova, M.
Powiązania:
https://bibliotekanauki.pl/articles/147444.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dense plasma focus (DPF)
X-ray generation
X-ray dosimetry
exposure dose
absorbed dose
Opis:
A review of some experimental results obtained using the dense plasma focus (DPF) device PF-1000 is presented. The copper Ka1,2 radiation line generated by DPF in the case of device anode made of copper was the main object of this study. The predominance of this characteristic radiation over other kinds of radiation in the DPF X-ray spectrum is shown. A brief description of a new DPF 6.0 device as well as a radioenzymology experiment carried out within this device is presented.
Źródło:
Nukleonika; 2006, 51, 1; 21-28
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of pre-sowing magnetic biostimulation on germination and yield of wheat
Autorzy:
Pietruszewski, S.
Powiązania:
https://bibliotekanauki.pl/articles/24995.pdf
Data publikacji:
1999
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
wheat
Jara cultivar
wheat cultivar
yield
Henika cultivar
magnetic biostimulation
magnetic exposure dose
germination
Źródło:
International Agrophysics; 1999, 13, 2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of variable magnetic field stimulation on growth of aboveground parts of potato plants
Autorzy:
Marks, N.
Szecowka, P.S.
Powiązania:
https://bibliotekanauki.pl/articles/24275.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
potato plant
potato tuber
field stimulation
magnetic field
magnetic induction
exposure dose
growth
stem mass
leaf mass
aboveground part
Źródło:
International Agrophysics; 2010, 24, 2; 165-170
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ stymulacji sadzeniaków zmiennym polem magnetycznym na kształt bulw ziemniaka
Impact of the stimulation of seed-potatoes with a variable magnetic field on the shape of potato bulbs
Autorzy:
Marks, N.
Szecówka, P.
Powiązania:
https://bibliotekanauki.pl/articles/290917.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
solenoid
pole magnetyczne
indukcja magnetyczna
czas
dawka ekspozycyjna
bulwa
ziemniak
kształt
magnetic field
magnetic induction
time
exposure dose
potato bulb
shape
Opis:
Praca zawiera wyniki badań nad wpływem zmiennego pola magnetycznego zastosowanego do stymulacji sadzeniaków na kształt bulw ziemniaka (Solanum Tuberosum) roślin potomnych. Do oceny kształtu zastosowano współczynnik sferyczności (wydłużenia i spłaszczenia) będący relacją a:c, a:b i b:c. Do badań przyjęto odmianę Vineta, W wyniku przeprowadzonych badań stwierdzono istotny statystycznie wpływ zmiennego pola magnetycznego na kształt bulw ziemniaka. Porównując współczynniki kształtu bulw stymulowanych i niestymulowanych (kontrola), można stwierdzić, że pole magnetyczne działa hamująco na deformację bulw wywołaną czynnikami modyfikującymi.
The work contains results of tests of the impact of the variable magnetic field used for stimulation of seed-potatoes on the shape of potato bulbs (Solanum Tuberosum) of daughter plants. The shape was evaluated with the use of the coefficient of sphericality (elongation and flattening), which is an a:c, a:b and b:c relation. The kind of potato used for the analysis was the Vineta variety. The performed tests proved the statistically important impact of the variable magnetic field on the shape of potato bulbs. The comparison of coefficients of the shape of stimulated and unstimulated bulbs (check) suggests that the magnetic field hinders the deformation of bulbs caused by modification agents.
Źródło:
Inżynieria Rolnicza; 2010, R. 14, nr 5, 5; 181-188
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czy opatrunek gipsowy wpływa na indeks ekspozycji i dose area product? : Odpowiedź na przykładzie radiografii nadgarstka
Are the plaster cast have influence on exposure index and dose area product value? : Based on the wrist radiography
Autorzy:
Nowak, P.
Murzyn, K.
Pasieka, E.
Powiązania:
https://bibliotekanauki.pl/articles/112147.pdf
Data publikacji:
2018
Wydawca:
Indygo Zahir Media
Tematy:
indeks ekspozycji
nadgarstek
zdjęcie rentgenowskie
opatrunek gipsowy
dose area product
exposure index, wrist
radiography
plaster cast
Opis:
Złamania dystalnej części kości promieniowej należą do jednych z najczęstszych urazów kości. W przypadku tego typu urazów podstawnym badaniem obrazowym, ze względu na niski koszt wykonania i ogólną dostępność, jest zdjęcie rentgenowskie. Standardowo radiografię stawu nadgarstkowego wykonuje się w projekcji: tylno-przedniej, skośnej i bocznej. Dodatkowymi badaniami są radiogramy w odchyleniu promieniowym lub łokciowym, a także zdjęcie celowane na kanał nadgarstka oraz kość łódeczkowatą. Cel: Celem pracy była retrospektywna analiza wartości dose area product i indeksu ekspozycji podczas radiografii stawu nadgarstkowego u pacjentów z zastosowanym opatrunkiem gipsowym oraz bez, w zależności od wielkości pola kolimacji rentgenogramu, a także wykorzystanych do diagnostyki parametrów ekspozycji. Materiały i metody: Analizie retrospektywnej poddano 208 losowo wybranych radiogramów stawu nadgarstkowego wykonanych w Zakładzie Radiologii Uniwersyteckiego Szpitala Klinicznego w Białymstoku aparatem RTG Axiom Aristos firmy Siemens. Badanie obejmowało wartości dose area product i indeksu ekspozycji, napięcia anodowego, obciążenia prądowo-czasowego oraz wiel¬kości pól kolimacji. Zebrane dane poddano analizie statystycznej przy użyciu programu Statistica 12,5 oraz MS Excel 2013. Wyniki: Większą część osób, którym wykonano radiogramy, sta¬nowiły kobiety. W tej grupie średnia wieku wyniosła 63,79 lat, natomiast średnia wieku mężczyzn była równa 47,56 lat. Średnia wielkość pola kolimacji rentgenogramu z grupy objętej bada¬niem wyniosła 324,17 cm2. Przy założeniu, że wartość referen¬cyjna pola kolimacji wynosi 234 cm2 (13 x 18 cm), to 160 (72,92%) zdjęć miało pole kolimacji większe od wartości referencyjnej, natomiast przy przyjęciu 432 cm2 (18 x 24 cm) jako wartość odniesienia tylko 35 (16,83%) radiogramów było większych od wartości wzorcowej. Wartość współczynnika ekspozycji wynio¬sła średnio 645,87 z wartością maksymalną równą 2980,00, na¬tomiast najniższa wartość była równa 141,00. Średnia wartość DAP w grupie objętej badaniem wyniosła 0,02 Gy∙cm2, przy od¬chyleniu standardowym 0,01 Gy∙cm2. Największa odnotowana wartość współczynnika DAP wyniosła 0,07 Gy∙cm2, natomiast najmniejsza 0,01 Gy∙cm2. Testy statystyczne wykazały korelację między polem powierzchni a DAP na poziomie rs = 0,78 i polem powierzchni a EXI rs = 0,19 oraz między wartością DAP (p = 0,00) i EXI (p = 0,00) a obecnością opatrunku gipsowego. Wnioski: W radiografii cyfrowej bezpośredniej (system Siemens) opatrunek gipsowy wpływa w istotny sposób na wartości DAP, zwiększając go średnio o 0,01 Gy∙cm2 oraz EXI, zmniejszając jego wartość niemal o połowę. Także zwiększenie pola kolimacji po¬woduje zwiększenie wartości DAP i EXI w radiografii nadgarstka.
Distal part radial bone fractures are one of the most common types of trauma. The basis of imaging examination of the injury is radiography. The advantages of the X-ray examination are low costs and widespread availability. Standard projections for the wrist are posteroanterior and lateral views. However, there are many ancillary views like a radiograms obtained with radial or ulnar deviation and carpal tunel. Aim: The aim of the study is retrospective analysis of dose area product and exposure index during radiography of the wrist. The analysis included value collimation size and exposure para¬meters depending on whether plaster immobilization was used or not. Materials and methods: We conduct retrospective analysis of randomly selected 208 radiographs of the wrist. X-ray photos were taken of patients at the Department of Radiology, Medi¬cal University Hospital in Bialystok, with Axiom Aristos Siemens. The analysis included value of the dose area product, exposure index, tube potential, tube current-time product and collima¬tion field. Statistical analysis was done using Statistica 12.5 and MS Excel 2013. Results: The most frequently radiographs were taken for wo¬men which average age was 63,79 while average age for men was 47,56. The average size of X-ray was 324,17 cm2. Assuming that the reference value of the collimation field is 234 cm2 (160x160), 160 (72.92%) images had collimation field greater than reference value. On the other hand when reference va¬lue is 432 cm2 (18 x 24 cm) only 35 (16.83%) of the radiographs were greater. The average exposure index value was 645,87, while the maximum value was 2980,00 and minimum value was 141,00. The average DAP in study group was 0,02 Gy∙cm2, SD = 0,01 Gy∙cm2. The largest recorded DAP was 0,07 Gy∙cm2, while the smallest was 0,01 Gy∙cm2. Statistic tests showed a signifi¬cant dependence between collimation field size value and DAP (rs = 0 ,78), c ollimation fi eld s ize v alue a nd E XI ( rs = 0 ,19); D AP (p = 0,00) and EXI (p = 0,00), and presence of plaster cast. Conclusions: In digital radiology (Siemens), plaster cast have a si¬gnificant influence on DAP, increasing it 0,01 Gy∙cm2 on average and EXI reduced its value almost by half. The increased surface area of the radiographs causes increased DAP and EXI.
Źródło:
Inżynier i Fizyk Medyczny; 2018, 7, 2; 85-91
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of exposure of workers to ionizing radiation from radioiodine and technetium in nuclear medicine departmental facilities
Ocena narażenia pracowników na promieniowanie jonizujące radiojodu i technetu w zakładach medycyny nuklearnej
Autorzy:
Krajewska, Grażyna
Pachocki, Krzysztof A.
Powiązania:
https://bibliotekanauki.pl/articles/2166302.pdf
Data publikacji:
2014-11-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
radiojod 131I
technet 99mTc
medycyna nuklearna
dawka skuteczna
ekspozycja zawodowa
radioiodine 131I
technetium 99mTc
nuclear medicine
effective dose
occupational exposure
Opis:
Background: Due to its use of ionising radiation, the field of nuclear medicine is a unique and significant part of medical diagnostics and patient treatment. The aim of this study was to assess the internal exposure of nuclear medicine employees to radioiodine 131I and technetium 99mTc as well as to assess the external exposure doses. Material and Methods: The radioiodine 131I and technetium 99mTc contents in the thyroid of staff members (about 100 persons) dealing with these radionuclides have been measured in four departments of nuclear medicine. The measurements were conducted with a portable detection unit for in situ measurements of radioiodine and technetium. High sensitivity environmental thermoluminescent dosimeters (TLD) were used to measure the external exposure dose. Results: The average values and ranges of radioiodine 131I activity measured in the thyroids of all of the medical units' employees were: 83 Bq (range: 70-250 Bq), 280 Bq (range: 70-4000 Bq), 275 Bq (range: 70-1000 Bq) for technical staff, nuclear medicine staff and hospital services staff, respectively. The mean value of technetium 99mTc content in the thyroids of nuclear medicine staff was approximately 1500 Bq (range: 50- -1800 Bq). External exposure dose rates were in the range of 0.5-10 μGy/h. Conclusions: The calculated average effective dose for particular person caused by the inhalation of radioiodine 131I is below 5% of 20 mSv/year (occupational exposure limit). Med Pr 2013;64(5):625–630
Wprowadzenie: Ze względu na stosowanie promieniowania jonizującego medycyna nuklearna jest istotną i unikalną gałęzią metod diagnostycznych i leczniczych. Celem podjętych badań była ocena narażenia wewnętrznego pracowników zakładów medycyny nuklearnej na jod promieniotwórczy 131I i technet 99mTc oraz ocena dawek pochodzących z ekspozycji zewnętrznej. Materiał i metody: Pomiary zawartości radiojodu 131I i technetu 99mTc w tarczycy osób pracujących z tymi radionuklidami (ok. 100 osób) wykonano w 4 ośrodkach medycyny nuklearnej. Zastosowano przenośny zestaw detekcyjny mierzący radionuklidy in situ. Dawki pochodzące z ekspozycji zewnętrznej mierzono, wykorzystując środowiskowe dozymetry termoluminescencyjne (thermoluminescent dosimeters - TLD) o dużej czułości. Wyniki: Zawartość radiojodu 131I w tarczycy wynosiła średnio: 83 Bq (zakres aktywności: 70-250 Bq) w grupie personelu technicznego, 280 Bq (zakres: 70-4000 Bq) w grupie personelu medycznego i 275 Bq (zakres: 70-1000 Bq) w grupie personelu pomocniczego. Średnia zawartość technetu 99mTc w tarczycy wynosiła ok. 1500 Bq (zakres: 50-1800 Bq). Otrzymana moc dawek pochodzących z ekspozycji zewnętrznej mieściła się w zakresie 0,5-10 μGy/godz. Wnioski: Oszacowana średnia dawka skuteczna pochodząca z inhalacji radiojodu 131I stanowiła mniej niż 5% rocznego limitu dla narażenia zawodowego, które wynosi 20 mSv/rok. Med. Pr. 2013;64(5):625–630
Źródło:
Medycyna Pracy; 2013, 64, 5; 625-630
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Międzynarodowe podstawowe normy ochrony przed promieniowaniem i bezpieczeństwa źródeł promieniowania
“Radiation Protection and Safety of Radiadion Sources: International Basic Safety Standards” (No.GSR Part 3 IAEA, Vienna 2014)
Autorzy:
Musiałowicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/214664.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
bezpieczeństwo radiacyjne
bezpieczeństwo fizyczne
dawka efektywna
dawka równoważna
dawka graniczna
ogranicznik dawki
poziom odniesienia
dozór jądrowy
narażenie planowane
narażenie wyjątkowe
narażenie istniejące
narażenie zawodowe
narażenie ludności
narażenie medyczne
optymalizacja
ochrona przed promieniowaniem
równoważnik dawki
radiation safety
nuclear security
effective dose
equivalent dose
dose limit
dose constraint
reference level
regulator body
planned exposure
emergency exposure
existing exposure
occupational exposure
population exposure
medical exposure
optimisation
radiation protection
dose equivalent
Opis:
W artykule omówiono wydaną w roku ubiegłym przez MAEA publikację zawierającą „MIĘDZYNARODOWE PODSTAWOWE NORMY OCHRONY PRZED PROMIENIOWANIEM I BEZPIECZEŃSTWA ŹRÓDEŁ PROMIENIOWANIA”. Odrębnie scharakteryzowano wymagania dotyczące różnych sytuacji narażenia: planowanego narażenia, wyjątkowego narażenia i istniejącego narażenia. W zakończeniu artykułu, jego autor i współautor poprzednich wydań NORM (1967, 1996), przedstawia swoją opinię na temat omawianej publikacji.
New IAEA publication entitled “Radiation Protection and Safety of Radiadion Sources: International Basic Safety Standards”. (No.GSR PART 3 IAEA) was described in the paper. The main parts of that publication concerning different exposure situations: planned exposure, emergency exposure, existing exposure are discussed separately. In the conclusion author of the article and simultaneously co-author of former editions (1967, 1996) of the BESIC SAFETY REQUIREMENTS presents his own opinion on the described book.
Źródło:
Postępy Techniki Jądrowej; 2015, 3; 15-22
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Does occupational exposure to low ionizing radiation affect endothelium health?
Autorzy:
Al-Massarani, G.
Najjar, F.
Powiązania:
https://bibliotekanauki.pl/articles/147716.pdf
Data publikacji:
2013
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
circulating endothelial cells (CEC)
occupational exposure
low-dose ionizing radiation
Opis:
The aim of this study was to assess the effect of low-radiation exposure on detachment of the vascular endothelial cells. Circulating endothelial cells (CEC) were measured in the peripheral blood by an immunomagnetic separation (IMS) technique in 63 workers occupationally exposed to low-level ionizing radiation at the Atomic Energy Commission of Syria and in 28 controls. We found a significant difference in CEC numbers in the peripheral blood of the workers exposed to low-level ionizing radiation in comparison with those of the control samples (p = 0.0001) and no significant difference in the proportion of other blood elements in the peripheral circulation. Elevated number of CEC in occupational workers exposed to low doses of ionizing radiation may reflect an early affection of the endothelium. Long-term follow-up of these workers must be conducted to determine the clinical value of CEC as an early indicator of cardiovascular disease induced as a result of chronic occupational exposure to low doses of ionizing radiation.
Źródło:
Nukleonika; 2013, 58, 4; 527-531
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Occupational exposure to radon for underground tourist routes in Poland: Doses to lung and the risk of developing lung cancer
Autorzy:
Walczak, Katarzyna
Olszewski, Jerzy
Politański, Piotr
Zmyślony, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2161885.pdf
Data publikacji:
2017-07-14
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational exposure
radon
effective dose
relative risk of lung cancer
equivalent dose to lung
underground tourist routes
Opis:
Objectives Radon concentrations for 31 Polish underground tourist routes were analyzed. The equivalent dose to the lung, the effective dose and the relative risk were calculated for employees of the analyzed routes on the grounds of information on radon concentrations, work time, etc. Material and Methods The relative risk for lung cancers was calculated using the Biological Effects of Ionizing Radiation (BEIR) VI Committee model. Equivalent doses to the lungs of workers were determined using the coefficients calculated by the Kendall and Smith. The conversion coefficient proposed by the International Atomic Energy Agency (IAEA) in the report No. 33 was used for estimating the effective doses. Results In 13 routes, the effective dose was found to be above 1 mSv/year, and in 3 routes, it exceeded 6 mSv/year. For 5 routes, the equivalent dose to lungs was higher than 100 mSv/year, and in 1 case it was as high as 490 mSv/year. In 22.6% of underground workplaces the risk of developing lung cancer among employees was about 2 times higher than that for the general population, and for 1 tourist route it was about 5 times higher. The geometric mean of the relative risk of lung cancer for all workers of underground tourist routes was 1.73 (95% confidence interval (CI): 1.6–1.87). Routes were divided into: caves, mines, post-military underground constructions and urban underground constructions. Conclusions The difference between levels of the relative risk of developing lung cancer for all types of underground tourist routes was not found to be significant. If we include the professional group of the employees of underground tourist routes into the group of occupational exposure, the number of persons who are included in the Category A due to occupational exposure may increase by about 3/4. The professional group of the employees of underground tourist routes should be monitored for their exposure to radon. Int J Occup Med Environ Health 2017;30(5):687–694
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 5; 687-694
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of annual exposure of private farmers to whole body mechanical vibration on selected family farms of plant production profile
Autorzy:
Solecki, L
Powiązania:
https://bibliotekanauki.pl/articles/51452.pdf
Data publikacji:
2010
Wydawca:
Instytut Medycyny Wsi
Tematy:
occupational exposure
agriculture
occupational disease
human disease
family farm
plant production
private farmer
farmer exposure
annual exposure
whole body vibration
mechanical vibration
daily exposure
vibration dose
vibration acceleration
noise
Źródło:
Annals of Agricultural and Environmental Medicine; 2010, 17, 2; 243-250
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time of exposure to grain processing disinfection in strong electric fields
Autorzy:
Bereka, O.
Usenko, S.
Powiązania:
https://bibliotekanauki.pl/articles/411017.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Oddział w Lublinie PAN
Tematy:
strong electric field decontamination processing
grain weight
nomogram
treatment dose
ozone treat-ment exposure
humidity
Opis:
A prototype installation is presented developed at the Department of Electric and Electro Technology of the National University of Life and Environmental Sciences of Ukraine, in which, with appropriate electric field intensity in air inclusions partial grain mass discharges are occurring and, accordingly, throughout the volume of products ozone is formed, the concentration of which is governed by the electric field. The results of investigation of barley moisture effect on ozone concentration in the grain mass under the action of a strong electric field are discussed and a nomogram is developed for determining the time required for an effective dose of antiseptic treatment of barley.
Źródło:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes; 2013, 2, 2; 27-30
2084-5715
Pojawia się w:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The risk of hearing loss associated with occupational exposure to organic solvents mixture with and without concurrent noise exposure: A systematic review and meta-analysis
Autorzy:
Hormozi, Maryam
Ansari-Moghaddam, Alireza
Mirzaei, Ramazan
Dehghan Haghighi, Javid
Eftekharian, Fatemeh
Powiązania:
https://bibliotekanauki.pl/articles/2161922.pdf
Data publikacji:
2017-06-19
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
odds ratio
occupational exposure
organic solvents
dose–response relationship
hearing loss
noise
Opis:
This study is a meta-analysis of the previous epidemiological studies which investigated the quantitative estimates of the association between independent or combined exposure to noise and mixed organic solvents and hearing loss until October 2014. Overall, 15 studies with information on 7530 individuals (6% female) were included. Having assessed – by puretone audiometry – the adjusted odds ratio estimates for the association between solvents mixture exposure and the risk of developing hearing loss stood at 2.05 (95% confidence interval (CI): 1.44–2.9). Similarly, for subjects who were concurrently exposed to noise and solvents mixture, an OR of 2.95 (95% CI: 2.1–4.17) was obtained. There was some evidence of heterogeneity within each of the 2 exposure groups (p heterogeneity < 0.001). This heterogeneity was not explained by differences in strength of effect between duration of exposure, the number of solvent and exposure index in subgroups of solvents mixture exposure. Based on the available data, our analysis has provided the evidence of increased risk of developing hearing loss for workers exposed to organic solvents even at quite low concentration. Moreover, if such exposure is accompanied by noise, it will exacerbate the extent of hearing loss. Int J Occup Med Environ Health 2017;30(4):521–535
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 4; 521-535
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radon events in the U-mine environment and related radiation exposure
Autorzy:
Križman, M. J.
Rojc, J.
Peter, J. E.
Powiązania:
https://bibliotekanauki.pl/articles/148916.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
uranium mine
environment
radon event
effective dose
Opis:
The term �gradon event�h indicates here a sudden appearance of enhanced radon concentrations, observed like well expressed peaks in time series of radon concentrations. The peaks are superimposed on normal diurnal periodical curves. The characteristics of radon events are high peak values, a rather short duration and a low radon equilibrium factor. Since radon events appear only in the environment near significant radon emission sources, they were investigated in more detail in the case of the former .irovski Vrh uranium mine (Slovenia), using the existing network of continuous radon progeny measuring devices. Eight different types of radon events were identified in the vicinity of the U-mine disposal sites, lasting for some hours and with the range of their peak levels of equilibrium equivalent concentrations (EEC) of radon from a few Bq�Em.3 to over 200 Bq�Em.3. Exposures to radon events in units of Bq�Eh�Em.3 were estimated for adult individuals of the reference group. They resulted in relatively high effective doses of the range 1.5 �ĘSv per a single event, thus exceeding, e.g. the total effective dose for the public due to radioactive discharges from most nuclear facilities during the whole year.
Źródło:
Nukleonika; 2010, 55, 4; 529-533
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radon exposure in kindergartens in one Bulgarian district
Autorzy:
Angelova, Antoaneta
Chobanova, Nina
Kunovska, Bistra
Djunakova, Desislava
Ivanova, Kremena
Stojanovska, Zdenka
Powiązania:
https://bibliotekanauki.pl/articles/24202747.pdf
Data publikacji:
2023
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
Bulgaria
effective dose
kindergarten
passive detector
radon concentration
Opis:
The major part of the radiation dose that humans receive from natural radioactive sources is due to inhalation of radon and its decay products. The study focuses on radon concentration (CRn) investigation in kindergartens and nurseries in the district of Montana. The infl uence of building characteristics on CRn was evaluated. The measurement of the CRn was performed using passive detectors. The survey was carried out between December 2019 and May 2020 with a total number of 602 detectors. The average value of CRn in the premises of the studied kindergartens and nurseries in this district is 125 Bq·m−3 , and the geometric mean (GM) value is 88 Bq·m−3 . The buildings that have built ventilation and sewerage systems have lower CRn. The effective doses of the children and workers were evaluated in order to assess the radon exposure.
Źródło:
Nukleonika; 2023, 68, 2; 51--56
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure to ionizing radiation by service personnel working with cyclotrons used to produce radiopharmaceuticals in PET diagnostics
Autorzy:
Biegała, Michał
Jakubowska, Teresa
Wrzesień, Małgorzata
Albiniak, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2152980.pdf
Data publikacji:
2022
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
nuclear medicine
PET
equivalent dose
service
radiological protection
cyclotron
Opis:
Objectives While working with cyclotrons used for the production of radiopharmaceuticals, workers can experience significant exposure to the adverse effects of ionizing radiation. The aim of this paper was to determine the typical level of such exposure received by such personnel while servicing cyclotrons. Material and Methods Exposure was assessed using TLD detectors placed in an anthropomorphic phantom, as well as dose meter to determine whole body and eye lens exposure. The phantom was placed in locations receiving the greatest exposure to ionizing radiation during service activities. The time spent by employees during servicing was assessed based on routine visits by service technicians. The obtained results were compared with readings of detectors worn by employees during service activities. Results The highest equivalent doses in the thoracic area were found to be received by the lungs (211.16 μSv/year). In the head and neck area, the highest dose was measured in the eye lens (3410 μSv/year). The effective dose for the whole body was found to be 1154.4 μSv/year, based on the phantom, and 149 μSv per service visit (1192 μSv/year), based on the dose meters carried by the workers. Conclusions Service workers are exposed to significant doses of ionizing radiation, representing a clear radiological protection issue. To reduce exposure to eye lenses, it is recommended to use protective goggles when working with highly-radioactive elements.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2022, 35, 6; 753-760
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dose-dependent relationship between prenatal exposure to fine particulates and exhaled carbon monoxide in non-asthmatic children. A population-based birth cohort study
Autorzy:
Jędrychowski, Wiesław A.
Maugeri, Umberto
Spengler, John
Mróz, Elżbieta
Flak, Elżbieta
Klimaszewska-Rembiasz, Maria
Jacek, Ryszard
Sowa, Agata
Powiązania:
https://bibliotekanauki.pl/articles/2179792.pdf
Data publikacji:
2013-03-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
exhaled CO
prenatal exposure
fine particulate matter
healthy non-asthmatic children
Opis:
Objectives: The main goal of the study was to assess possible association between fetal exposure to fi ne particulate matter ($\text{PM}_\text{2.5}$) and exhaled carbon monoxide (eCO) measured in non-asthmatic children. Material and Methods: The subjects include 118 children taking part in an ongoing population-based birth cohort study in Kraków. Personal samplers of $\text{PM}_\text{2.5}$ were used to measure fi ne particle mass in the fetal period and carbon monoxide (CO) in exhaled breath from a single exhalation effort at the age of 7. In the statistical analysis of the effect of prenatal $\text{PM}_\text{2.5}$ exposure on eCO, a set of potential confounders, such as environmental tobacco smoke (ETS), city residence area, sensitization to house dust allergens and the occurrence of respiratory symptoms monitored over the seven-year follow-up was considered. Results: The level of eCO did not correlate with the self-reported ETS exposure recorded over the follow-up, however, there was a positive signifi cant relationship with the prenatal $\text{PM}_\text{2.5}$ exposure (non-parametric trend p = 0.042). The eCO mean level was higher in atopic children (geometric mean = 2.06 ppm, 95% CI: 1.58–2.66 ppm) than in non-atopic ones (geometric mean = 1.57 ppm, 95% CI: 1.47–1.73 ppm) and the difference was statistically signifi cant (p = 0.036). As for the respiratory symptoms, eCO values were associated positively only with the cough severity score recorded in the follow-up (nonparametric trend p = 0.057). In the nested multivariable linear regression model, only the effects of prenatal $\text{PM}_\text{2.5}$ and cough severity recorded in the follow-up were related to eCO level. The prenatal $\text{PM}_\text{2.5}$ exposure represented 5.1%, while children’s cough represented only 2.6% of the eCO variability. Conclusion: Our study suggests that elevated eCO in non-asthmatic children may result from oxidative stress experienced in the fetal period and that heme oxygenase (HO) activity in body tissues may be programmed in the fetal period by the exposure to fi ne particulate matter.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2013, 26, 1; 73-82
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The assessment of the ionizing radiation dose received by patients during some diagnostic X-ray examinations carried out on the basis of the working procedures in the health care entities
Autorzy:
Bekas, M.
Waniewska, E.
Wardzinski, A.
Wieprzowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/874288.pdf
Data publikacji:
2017
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
assessment
ionizing radiation
radiation dose
patient
diagnostic method
X-ray method
radiation exposure
working procedure
health care
human health
health risk
Opis:
Background. X-ray examination is a popular and universally used injury and disease diagnostic method. A distinctive X ray examination feature is that it can be done quickly which is extremely important in case of the need for rapid diagnosis of patients in life threatening condition. Another advantage of the X-ray examinations is also relatively low cost of carry. However, X-ray examination involve adverse health effects. During the examination the patient is subjected to ionizing radiation that might have impact on his health. Objective. The aim of this study has been to determine and assess the size of the entrance surface doses (ESD) received by patients during selected X-ray examinations performed on the basis of the medical working procedures available in healthcare entities in Masovian Voivodeship in Poland. Materials and Method. The examinations were conducted for 71 X-ray units located in the Masovian Voivodeship. Measurements of doses received by the patients were based on our own validated test methods. Results. It was found that the range applied to the high voltage in healthcare entities does not always coincide with the values specified in the standard procedures. It was found in the skull projection radiography AP and LAT that the recorded values were from range 60 to 82 kV (the average value of 74 kV) while in accordance with a standard procedure they should be in the range from 65 to 75 kV. Only in case of cervical spine radiography in the AP projection, the LAT exposure conditions were matching with the standard obligatory procedures in Poland. The consequence of selecting exposure conditions are significant differences in the size of the doses the patient receive during the same medical procedures. The greatest range of ESD doses was found during radiography of the thoracic spine in the projection AP and LAT. The projection LAT measured values were in the range of 523 to 10550 μGy (average value 2175 μGy). Conclusions. It is necessary to update immediately the standard procedures and to develop detailed guidelines for the preparation of working procedures in X-ray rooms.
Wprowadzenie. Badania rentgenowskie są powszechnie stosowaną metodą diagnozowania urazów i schorzeń występujących u pacjentów. Największą zaletą tych badań jest szybkość ich wykonania, co jest niezwykle istotne w przypadku konieczności postawienia szybkiej diagnozy medycznej u pacjentów w ciężkim stanie zagrażającym ich życiu. Badania rentgenowskie niosą jednakże ze sobą także negatywne skutki zdrowotne. W trakcie ich przeprowadzania pacjent poddany jest działaniu promieniowania jonizującego, które nie jest obojętne dla zdrowia. Cel. Celem badań było oszacowanie wielkości wejściowej dawki powierzchniowej (ESD) jaką otrzymują pacjenci podczas wybranych badań rentgenowskich przeprowadzonych w oparciu o procedury robocze obowiązujące w placówkach ochrony zdrowia na terenie województwa mazowieckiego. Materiał i metody. Zbadano 71 aparatów rentgenowskich wykorzystywanych w placówkach ochrony zdrowia na terenie województwa mazowieckiego. Pomiary dawek otrzymywanych przez pacjentów podczas badań rentgenowskich przeprowadzono własnymi zwalidowanymi metodami badawczymi. Wyniki. Stwierdzono, iż zakres wartości wysokiego napięcia dobieranego przez personel medyczny na aparatach rentgenowskich w placówkach ochrony zdrowia nie zawsze pokrywa się z wartościami określonymi w procedurach wzorcowych. Stwierdzono, iż w radiografii czaszki w projekcji AP i LAT wartość wysokiego napięcia była od 60 do 82 kV (wartość średnia 74 kV), zaś zgodnie z procedurą wzorcową powinny mieścić się w zakresie od 65 do 75 kV. Najlepszą zgodność pomiędzy wartościami wysokiego napięcia stosowanymi w pracowniach rtg a tymi określonymi w procedurach wzorcowych obowiązujących w Polsce stwierdzono w przypadku radiografii kręgosłupa szyjnego. Konsekwencją tak dobieranych warunków ekspozycji są znaczące różnice w wielkości dawek promieniowania otrzymywanych przez pacjentów dla tych samych procedur medycznych. Największą rozpiętość dawek ESD stwierdzono w trakcie radiografii kręgosłupa piersiowego w projekcji AP oraz LAT. W projekcji LAT zmierzone wartości były w przedziale od 523 do 10550 μGy (wartość średnia 2175 μGy). Wnioski. Niezbędne jest jak najszybsze uaktualnienie procedur wzorcowych oraz opracowanie szczegółowych wytycznych dotyczących przygotowywania procedur roboczych w pracowniach rentgenowskich.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2017, 68, 1
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Infl uence of an Increased Controlled Dose of Irradiance on the Change of Selected Physicochemical Properties of Paint Systems Used in Rolling Stock
Autorzy:
Garbacz, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2203230.pdf
Data publikacji:
2022
Wydawca:
Instytut Kolejnictwa
Tematy:
accelerated weathering
xenon-arc radiation
paint coatings
irradiance
radiant exposure
hardness
gloss
colour
rolling stock
Opis:
The article presents the results of ageing tests with the use of laboratory light radiation tested according to the EN ISO 16474-2 standard for painting systems used in rolling stock. Th e influence of aging on such properties as gloss, colour and hardness, was determined using two different irradiance settings of the order of 60 W/m2 and 120 W/m2 for the wavelength 300÷400 nm and the same levels of radiant exposure. In addition, this study describes the most important information about laboratory aging tests with simulation of sunlight, temperature, moisture including rain, which are included in ISO standardised test methods. The influence of weather parameters has been described, in particular the influence of an increased dose of irradiance on the degradation of selected physicochemical properties of coatings and the possibility of the predicted ageing progress (changes in selected properties). The obtained results of laboratory tests allow to make certain assumptions regarding the increase of the dose of irradiance and thus the shortening of the laboratory testing time in the context of the assessment of the most desirable properties of the coating for a given application with the use of laboratory ageing tests.
Źródło:
Problemy Kolejnictwa; 2022, 197; 99--115
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Drgania i hałas na stanowiskach pracy w środkach komunikacji miejskiej - badania dozymetryczne
Evaluation of noise and vibration exposure at workplaces in city transportation using noise and vibration dose meters
Autorzy:
Koton, J.
Majewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/179181.pdf
Data publikacji:
2004
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
hałas
hałas na stanowisku pracy
hałas komunikacyjny
noise
traffic noise
Opis:
Z doniesień literaturowych, zwłaszcza ostatniego dziesięciolecia, wynika, że skojarzone działanie na organizm człowieka dwóch lub więcej szkodliwych i uciążliwych czynników środowiska pracy potęguje niekorzystne skutki działania każdego z nich występującego oddzielnie. Do stanowisk pracy, na których występują łącznie różne czynniki środowiska, należą niewątpliwie stanowiska obsługi wszelkiego rodzaju pojazdów, w tym pojazdów komunikacji miejskiej. W artykule przedstawiono wyniki badań jednoczesnej ekspozycji kierowców na drgania i hałas w autobusach miejskich, tramwajach i w metrze. Uzyskane wyniki porównano z wartościami kryterialnymi ustalonymi dla tych czynników ze względu na ochronę zdrowia w przepisach krajowych i w dyrektywach Unii Europejskiej.
Drivers of city transportation are exposed to noise and vibration, among others, which may affect health, comfort and perception. In order to evaluate occupational exposure and to assess the risk arising from those two agents, measurements were carried out in Warsaw city buses, trams and metro. Daily exposure to noise and vibration was measured simultaneously, throughout the working day, using noise and vibration dose meters. The results of the measurements as well as a comparison of work conditions in specific kinds of city transportation are presented and discussed in this paper. Moreover, the obtained daily exposure to noise and vibration is compared with the requirements of Polish law and the safety requirements of Directive 2002/44/EC (vibration) and Directive 2003/10/EC (noise).
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2004, 7/8; 12-15
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Traffic-related particle emissions and exposure on an urban road
Emisja cząstek ze źródeł komunikacyjnych w mieście
Autorzy:
Połednik, B.
Piotrowicz, A.
Pawłowski, L.
Guz, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/205054.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vehicle emissions
mobile monitoring
particle concentration
commuters
deposition dose
emisje motoryzacyjne
monitoring mobilny
stężenie cząstek
uczestnik ruchu drogowego
narażenie zdrowotne
dawka osadzająca
Opis:
Extensive aerosol particle concentrations are one of the factors contributing to poor air quality in cities. The aim of this study is to assess particle number and mass concentrations on a road in Lublin, Poland, in peak and off-peak traffic hours and its impact on the particle exposure for commuters and pedestrians. Mobile monitoring and fixed-site measurements on the sidewalk along the established 2.1 km long route were conducted with the use of Mobile Air Pollution Analytic Laboratory equipped, among other things, with instruments measuring the real-time number and mass concentrations of particles with size range from 10 nm to 32 μm. The highest average concentrations of ultrafine particle number PN0.1 (25.4 ±11×103 pt/cm3; mean ± standard deviation), total particle number PN (29.2 ±12×103 pt/cm3) as well as mass concentrations of PM2.5 (29.1 ±7.6 μg/m3) and PM10 (45.4 ±10.3 μg/m3) were obtained in peak traffic hours for the part of the route with the most intensive traffic. The average particle number concentrations for the entire route and the part of route with the most intensive traffic in peak times were found to be about 3 to 4 times higher than in off-peak times. The average particle mass concentrations were about twice as high. Furthermore, the average values of the examined particle number and mass concentrations were higher for the on-road measurements than for fixed-site measurements. Moreover, a greater percentage of ultrafine particles was observed during mobile monitoring than in the fixed-site measurement points. It was established that a greater number and mass of particles, irrespectively of their size range, is deposited in the respiratory tract of commuters and pedestrians in peak hours than in off-peak hours. In peak times the average particle doses received by commuters and pedestrians equaled 4.8 ±2.4×109 pt/h or 29.6 ±10.7 μg/h (PM10) and 4.2 ±2.3×109 pt/h or 29.6 ±8.6 μg/h (PM10), respectively. Additionally, in both peak and off-peak hours greater particle doses were determined in the considered part of the route with the most intensive traffic; however, in off-peak traffic times pedestrians are more exposed to traffic-related pollutants than commuters. Overall, the obtained results reflect the importance of traffic-related particle emission measurements for exposure evaluations and the need of taking the actions aimed at decreasing it.
Celem pracy było określenie stężenia liczbowego i masowego cząstek na wybranych ulicach Lublina w godzinach szczytu oraz poza szczytem, a także ocena narażenia kierowców i pieszych na ich oddziaływanie. W ramach badań przeprowadzono zarówno pomiary mobilne, jak i stacjonarne w określonych punktach pomiarowych na trasie o długości 2,1 km. Mierzono w czasie rzeczywistym między innymi stężenia liczbowe i masowe cząstek o rozmiarach w zakresie od 10 nm do 32 μm. Najwyższe średnie koncentracje ultradrobnych cząstek PN0.1 (25,4 ±11×103 #/cm3) oraz koncentracje całkowitej liczby cząstek PN (29,2 ±12×103 #/cm3), a także stężenia masowe PM2.5 (29,1 ±7,6 μg/m3) oraz PM10 (45,4 ±10,3 μg/m3) rejestrowano w godzinach szczytu na wydzielonym odcinku trasy o największej intensywności ruchu. Średnie koncentracje cząstek mierzone w godzinach szczytu dla całej trasy oraz dla wydzielonego odcinka były, w zależności od wielkości cząstek, ok. 3-4 razy większe w porównaniu do wyników pomiarów dla godzin pozaszczytowych. Z kolei średnie stężenia masowe cząstek były około dwa razy większe. Ponadto, większe średnie stężenia liczbowe i masowe cząstek odnotowano dla pomiarów mobilnych niż dla stacjonarnych. Wyznaczone dawki dotyczące liczby i masy cząstek deponowanych w drogach oddechowych kierowców w godzinach szczytu wynosiły odpowiednio 4,8 ±2,4×109 #/h i 29,6 ±10,7 μg/h (PM10). Zarówno dla godzin szczytu, jak i poza szczytem, większe dawki deponowanych cząstek uzyskano dla wydzielonego odcinka trasy o największej intensywności ruchu. Podsumowując, otrzymane wyniki wskazują na istotność pomiarów cząstek emitowanych ze źródeł komunikacyjnych, szczególnie w kontekście narażenia uczestników ruchu drogowego na te cząstki.
Źródło:
Archives of Environmental Protection; 2018, 44, 2; 83-93
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena narażenia na promieniowanie jonizujące techników obsługujących gammakamery
Evaluation of exposure to ionizing radiation among gamma camera operators
Autorzy:
Domańska, Agnieszka A.
Bieńkiewicz, Małgorzata
Olszewski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/2166788.pdf
Data publikacji:
2014-11-04
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
promieniowanie jonizujące
medycyna nuklearna
dozymetria
dawka graniczna
ochrona radiologiczna
personel medyczny
ionizing radiation
nuclear medicine
Dosimetry
dose limit
radiation protection
medical staff
Opis:
Wstęp: Ochrona personelu placówki medycyny nuklearnej przed zagrożeniami wynikającymi ze stosowania promieniowania jonizującego jest istotnym aspektem ochrony radiologicznej osób fizycznych. Celem pracy była oceny narażenia zawodowego techników elektroradiologii wykonujących badania scyntygraficzne w Zakładzie Medycyny Nuklearnej Centralnego Szpitala Klinicznego UniwersytetuMedycznego w Łodzi, gdzie rocznie przeprowadzanych jest kilka tysięcy różnego rodzaju radioizotopowych badań diagnostycznych. Materiał i metody: W badanej placówce diagnostycznej zatrudnionych jest 10 techników (2013 r.), których narażenie podlega stałej kontroli za pomocą dozymetrii indywidualnej. Zebrano archiwalne dane dotyczące kwartalnych odczytów z dozymetrów na przestrzeni lat 2001-2010 i przeanalizowano dawki kwartalne wyrażone, jako równoważniki dawki Hp(10). Wyznaczono również dawki roczne oraz 5-letnie, odnosząc wyniki do obecnie obowiązujących norm prawnych. Dla wybranego okresu jednego roku zebrano również dane dotyczące liczby i rodzaju realizowanych w tym czasie badań, aby ocenić, czy istnieje zależność między łączną aktywnością radiofarmaceutyków podaną w tym czasie pacjentom a dawkami zarejestrowanymi u techników wykonujących te badania. Wyniki: W badanym 10-letnim okresie działalności placówki, najwyższa zarejestrowana u technika dawka roczna wynosiła 2 mSv, a najwyższa sumaryczna dawka 5-letnia - 7,1 mSv, co nie przekraczało 10% wartości granicznych dawki rocznej (20 mSv) i 5-letniej (100 mSv). Zaobserwowano dodatnią zależność liniową między wartościami kwartalnych dawek otrzymanych przez techników a łączną aktywnością radiofarmaceutyków podanych w tym okresie pacjentom. Wnioski: Przy zachowaniu zasad ochrony radiologicznej oraz warunków bezpiecznego stosowania promieniowania jonizującego dawki otrzymywane przez techników wykonujących badania scyntygraficzne są niskie, co potwierdza zaliczenie tej grupy zawodowej do pracowników kategorii B. Med. Pr. 2013;64(4):503–506
Background: Protection of nuclear medicine unit employees from hazards of the ionizing radiation is a crucial issue of radiation protection services. We aimed to assess the severity of the occupational radiation exposure of technicians performing scintigraphic examinations at the Nuclear Medicine Department, Central Teaching Hospital of Medical University in Łódź, where thousands of different diagnostic procedures are performed yearly. Materials and Methods: In 2013 the studied diagnostic unit has employed 10 technicians, whose exposure is permanently monitored by individual dosimetry. We analyzed retrospective data of quarterly doses in terms of Hp(10) dose equivalents over the years 2001-2010. Also annual and five-year doses were determined to relate the results to current regulations. Moreover, for a selected period of one year, we collected data on the total activity of radiopharmaceuticals used for diagnostics, to analyze potential relationship with doses recorded in technicians performing the examinations. Results: In a 10-year period under study, the highest annual dose recorded in a technician was 2 mSv, which represented 10% of the annual dose limit of 20 mSv. The highest total dose for a 5-year period was 7.1 mSv, less than 10% of a 5-year dose limit for occupational exposure. Positive linear correlation was observed between total activity of radiopharmaceuticals used for diagnostics in the period of three months and respective quarterly doses received by technicians performing examinations. Conclusions: Doses received by nuclear medicine technicians performing diagnostic procedures in compliance with principles of radiation protection are low, which is confirmed by recognizing the technicians of this unit as B category employees. Med Pr 2013;64(4):503–506
Źródło:
Medycyna Pracy; 2013, 64, 4; 503-506
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of resource allocation, exposure time and rotary speed of incubative eggs
Optymalizacja alokacji zasobów, czasu ekspozycji i prędkości obrotowej jaj inkubacyjnych
Autorzy:
Milenin, Dmytro
Lysychenko, Mykola
Milenin, Andriy
Koval, Leonid
Amirgaliyeva, Saltanat
Satymbekov, Maxatbek
Adikanova, Saltanat
Powiązania:
https://bibliotekanauki.pl/articles/27315410.pdf
Data publikacji:
2023
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
laser emission
radiation dose
incubating egg
emisja laserowa
dawka promieniowania
inkubowane jajo
Opis:
Recently, the laser technology of influencing biological objects in biology, medicine, and veterinary medicine has become widespread in order to activate certain biochemical and physiological processes in the organism. Any influence of electromagnetic radiation (in particular optical emission) requires the exact adherence to the recommended illumination dose to obtain a positive effect on the biological object. The article presents the results of a theoretical study concerning provision of uniform illumination of the egg’s surface, taking into account the location of the laser radiation source and rotating time of the egg.
Ostatnio technologia laserowego oddziaływania na obiekty biologiczne w biologii, medycynie i weterynarii stała się powszechna w celu aktywacji pewnych procesów biochemicznych i fizjologicznych w organizmie. Każdy wpływ promieniowania elektromagnetycznego (w szczególności emisji optycznej) wymaga dokładnego przestrzegania zalecanej dawki oświetlenia w celu uzyskania pozytywnego wpływu na obiekt biologiczny. W artykule przedstawiono wyniki badań teoretycznych dotyczących zapewnienia równomiernego oświetlenia powierzchni jaja, biorąc pod uwagę lokalizację źródła promieniowania laserowego i czas obrotu jaja.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2023, 13, 2; 15--19
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The awareness of caregivers about their children’s exposure to ionizing radiation accompanying medical procedures: the assessment study
Autorzy:
Jończyk-Potoczna, Katarzyna
Pucher, Beata
Strzelczuk-Judka, Lidia
Buraczyńska-Andrzejewska, Beata
Więckowska, Barbara
Krauss, Hanna
Biliński, Przemysław
Wojtyła-Buciora, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/2161993.pdf
Data publikacji:
2019-02-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
children
CT examination
parents
radiation protection
ionizing radiation
radiation dose
Opis:
Objectives The aim of the study was a survey-based assessment concerning parents of children undergoing CT examinations and their knowledge of detailed information about procedures involved in imaging diagnostics. Material and Methods A statistical analysis of 108 surveys of parents of children undergoing CT studies in the Department of Pediatric Radiology in Poznań, Poland was done, with the use of Statistica software. Results In result of the evaluation of all subsections of the substantive question number, the majority of answers were incorrect (68–98%). No correlation between the number of CT examinations conducted for a child and the number of correct answers to substantive questions was observed. No correlation between the number of CT examinations conducted for a child and the fact of noting the examination with the use of ionizing radiation down in a child’s health certificate was stated. The statistical analysis showed that children of parents who declared that the aim of the CT examination had been explained to them better underwent more of them. Conclusions Parents are poorly informed about a radiation dose and risk related to a CT examination procedure. Int J Occup Med Environ Health. 2019;32(1):65–73
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2019, 32, 1; 65-73
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of dose distribution around a computed tomography scanner in terms of exposure to scattered ionizing radiation of caregivers of pediatric patients
Autorzy:
Biegała, Michał
Brodecki, Marcin
Skoczylas, Krystian
Jakubowska, Teresa
Domienik-Andrzejewska, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/45912311.pdf
Data publikacji:
2024-09-10
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
effective dose
radiological protection
leukemia
CT scanner
probability of induction of leukemia
pediatric radiology
Opis:
Objectives During computed tomography (CT), a large amount of ionizing radiation is emitted to ensure high quality of the obtained radiological image. This study measured the dose distribution around the CT scanner and the exposure of people staying near the CT scanner during the examination. Material and Methods The measurements used an anthropomorphic phantom to assess human exposure to ionizing radiation. The probability of inducing leukemia and other cancers as a result of absorbing doses recorded around the CT device was also calculated. Results The highest exposure to scattered radiation in the proximity of the CT scanner is recorded at the gantry of the tomograph, i.e., 55.7 μGy, and the lowest, below lower detection limit of 6 μGy at the end of the diagnostic table. The whole-body detector placed on the anthropomorphic phantom located at the diagnostic table right next to the CT gantry recorded 59.5 μSv and at the end of the table 1.5 μSv. The average doses to the lenses in these locations were: 32.1 μSv and 2.9 μSv, respectively. Conclusions The probability of induction of leukemia or other types of cancer is low, but the need for people to stay in the examination room during a CT examination should be limited to the necessary minimum.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2024, 37, 3; 326-334
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies