Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "evaluation of exposure" wg kryterium: Wszystkie pola


Wyświetlanie 1-56 z 56
Tytuł:
Evaluation of exposure to nano-sized particles among transport and vehicle service workers
Autorzy:
Bujak-Pietrek, Stella
Mikołajczyk, Urszula
Powiązania:
https://bibliotekanauki.pl/articles/2087543.pdf
Data publikacji:
2021-11-19
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
ultrafine particles
particle number concentration
particle surface area concentration
nanoparticles exposure
diesel engine exhaust
particle number size distribution
Opis:
BackgroundExposure to fine and ultrafine particles from transport processes is a main consequence of emissions from engines, especially those with self-ignition. The particles released in these processes are a source of occupational and environmental particles exposure. The aim of this study was to assess the fine and nano-sized particles emission degree during work connected with transport and vehicle servicing.Material and MethodsThe tests were carried out at 3 workplaces of vehicles service and maintenance (a car repair workshop, a truck service hall, and a bus depot) during 1 work day in each of them. Measurements were performed using the following devices: DISCmini meters, GRIMM 1.109 optical counter and the DustTrak monitor. The number, surface area and mass concentration, and the number size distribution were analyzed.ResultsThe mean number concentration (DISCmini) increased during the analyzed processes, ranging from 4×104 p/cm3 to 8×104 p/cm3, and the highest concentration was found in the car repair workshop. The particles mean diameters during the processes ranged 31–47 nm, depending on the process. An increase in the surface area concentration value was observed in correlation with the particles number, and its highest concentration (198 m2/cm3) was found during work in the car repair workshop. The number size distribution analysis (GRIMM 1.109) showed the maximum value of the number concentration for particles sized 60 nm. The mean mass concentrations increased during the tested processes by approx. 40–70%, as compared to the background.ConclusionsAccording to the measurement results, all the workplaces under study constituted a source of an increase in all analyzed parameters characterizing emissions of nano-sized particles. Such working environment conditions can be harmful to the exposed workers; therefore, at such workplaces solutions for minimizing workers’ exposure, such as fume hoods or respiratory protection, should be used. Med Pr. 2021;72(5):489–500
Źródło:
Medycyna Pracy; 2021, 72, 5; 489-500
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Exposure to Impulse Noise at Personnel Occupied Areas During Military Field Exercises
Autorzy:
Młyński, R.
Kozłowski, E.
Usowski, J.
Jurkiewicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/177458.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
impulse noise
noise exposure
hearing damage risk criteria
weapon
Opis:
The tests reported in this paper were carried out to evaluate the exposure of soldiers to noise at operator and control positions during military field exercises. The tests were conducted during firing from a T-72 tank, a BWP-1 Infantry Fighting Vehicle, antitank guided missiles, a ZU-23-2K anti-aircraft gun, and a 2S1 GOZDZIK howitzer. The evaluation of noise exposure showed that the limit values of sound pressure level, referred to by both Polish occupational noise protection standards and the Pfander and Dancer hearing damage risk criteria developed for military applications, were repeatedly exceeded at the tested positions. Despite of the use of tank crew headgear, the exposure limit values of sound pressure level were exceeded for the crew members of the T-72 tank, the BWP-1 infantry fighting vehicle, and the 2S1 GOZDZIK howitzer. The results show that exposure of soldiers to noise during military field exercises is a potentially high hearing risk factor.
Źródło:
Archives of Acoustics; 2018, 43, 2; 197-205
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena narażenia na promieniowanie jonizujące techników obsługujących gammakamery
Evaluation of exposure to ionizing radiation among gamma camera operators
Autorzy:
Domańska, Agnieszka A.
Bieńkiewicz, Małgorzata
Olszewski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/2166788.pdf
Data publikacji:
2014-11-04
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
promieniowanie jonizujące
medycyna nuklearna
dozymetria
dawka graniczna
ochrona radiologiczna
personel medyczny
ionizing radiation
nuclear medicine
Dosimetry
dose limit
radiation protection
medical staff
Opis:
Wstęp: Ochrona personelu placówki medycyny nuklearnej przed zagrożeniami wynikającymi ze stosowania promieniowania jonizującego jest istotnym aspektem ochrony radiologicznej osób fizycznych. Celem pracy była oceny narażenia zawodowego techników elektroradiologii wykonujących badania scyntygraficzne w Zakładzie Medycyny Nuklearnej Centralnego Szpitala Klinicznego UniwersytetuMedycznego w Łodzi, gdzie rocznie przeprowadzanych jest kilka tysięcy różnego rodzaju radioizotopowych badań diagnostycznych. Materiał i metody: W badanej placówce diagnostycznej zatrudnionych jest 10 techników (2013 r.), których narażenie podlega stałej kontroli za pomocą dozymetrii indywidualnej. Zebrano archiwalne dane dotyczące kwartalnych odczytów z dozymetrów na przestrzeni lat 2001-2010 i przeanalizowano dawki kwartalne wyrażone, jako równoważniki dawki Hp(10). Wyznaczono również dawki roczne oraz 5-letnie, odnosząc wyniki do obecnie obowiązujących norm prawnych. Dla wybranego okresu jednego roku zebrano również dane dotyczące liczby i rodzaju realizowanych w tym czasie badań, aby ocenić, czy istnieje zależność między łączną aktywnością radiofarmaceutyków podaną w tym czasie pacjentom a dawkami zarejestrowanymi u techników wykonujących te badania. Wyniki: W badanym 10-letnim okresie działalności placówki, najwyższa zarejestrowana u technika dawka roczna wynosiła 2 mSv, a najwyższa sumaryczna dawka 5-letnia - 7,1 mSv, co nie przekraczało 10% wartości granicznych dawki rocznej (20 mSv) i 5-letniej (100 mSv). Zaobserwowano dodatnią zależność liniową między wartościami kwartalnych dawek otrzymanych przez techników a łączną aktywnością radiofarmaceutyków podanych w tym okresie pacjentom. Wnioski: Przy zachowaniu zasad ochrony radiologicznej oraz warunków bezpiecznego stosowania promieniowania jonizującego dawki otrzymywane przez techników wykonujących badania scyntygraficzne są niskie, co potwierdza zaliczenie tej grupy zawodowej do pracowników kategorii B. Med. Pr. 2013;64(4):503–506
Background: Protection of nuclear medicine unit employees from hazards of the ionizing radiation is a crucial issue of radiation protection services. We aimed to assess the severity of the occupational radiation exposure of technicians performing scintigraphic examinations at the Nuclear Medicine Department, Central Teaching Hospital of Medical University in Łódź, where thousands of different diagnostic procedures are performed yearly. Materials and Methods: In 2013 the studied diagnostic unit has employed 10 technicians, whose exposure is permanently monitored by individual dosimetry. We analyzed retrospective data of quarterly doses in terms of Hp(10) dose equivalents over the years 2001-2010. Also annual and five-year doses were determined to relate the results to current regulations. Moreover, for a selected period of one year, we collected data on the total activity of radiopharmaceuticals used for diagnostics, to analyze potential relationship with doses recorded in technicians performing the examinations. Results: In a 10-year period under study, the highest annual dose recorded in a technician was 2 mSv, which represented 10% of the annual dose limit of 20 mSv. The highest total dose for a 5-year period was 7.1 mSv, less than 10% of a 5-year dose limit for occupational exposure. Positive linear correlation was observed between total activity of radiopharmaceuticals used for diagnostics in the period of three months and respective quarterly doses received by technicians performing examinations. Conclusions: Doses received by nuclear medicine technicians performing diagnostic procedures in compliance with principles of radiation protection are low, which is confirmed by recognizing the technicians of this unit as B category employees. Med Pr 2013;64(4):503–506
Źródło:
Medycyna Pracy; 2013, 64, 4; 503-506
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of exposure to electromagnetic radiofrequency radiation in the indoor workplace accessible to the public by the use of frequency-selective exposimeters
Autorzy:
Gryz, Krzysztof
Karpowicz, Jolanta
Leszko, Wiesław
Zradziński, Patryk
Powiązania:
https://bibliotekanauki.pl/articles/2179019.pdf
Data publikacji:
2014-12-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational exposure
measurements
electromagnetic fields
exposure pattern
Opis:
Objectives: The aim of the study was to identify and assess electromagnetic radiofrequency radiation (EMRR) exposure in a workplace located in a publicly accessible environment, and represented by offices (where exposure is caused by various transmitters of local fixed indoor and outdoor wireless communication systems). Material and Methods: The investigations were performed in 45 buildings (in urban and rural areas in various regions of Poland), using frequency-selective electric field strength (E-field) exposimeters sensitive to the EMRR with a frequency range of 88–2500 MHz, split into 12 subbands corresponding to the operating frequencies of typical EMRR sources. The variability of the E-field was analyzed for each frequency range and the total level of exposure by statistical parameters of recorded exposimetric profiles: minimum, maximum, median values and 25–75th – percentiles. Results: The main sources of exposure to EMRR are mobile phone base transceiver stations (BTS) and radio-television transmitters (RTV). The frequency composition in a particular office depends on the building’s location. The E-field recorded in buildings in urban and rural areas from the outdoor BTS did not exceed respectively: medians – 0.19 and 0.05 V/m, 75th percentiles – 0.25 and 0.09 V/m. In buildings equipped with the indoor BTS antennas the E-field did not exceed: medians – 1 V/m, 75th percentiles – 1.8 V/m. Whereas in urban and rural areas, the median and 75th percentile values of the E-field recorded in buildings located near the RTV (within 1 km) did not exceed: 1.5 and 3.8 V/m or 0.4 and 0.8 V/m, for radio FM band or for TV bands, respectively. Conclusions: Investigations confirmed the practical applicability of the exposimetric measurements technique for evaluating parameters of worker’s exposure in both frequency- and time-domain. The presented results show EMRR exposure of workers or general public in locations comparable to offices to be well below international limits.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2014, 27, 6; 1043-1054
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Sound Exposure and Risk of Hearing Impairment in Orchestral Musicians
Autorzy:
Pawlaczyk-Łuszczyńska, M.
Dudarewicz, A.
Zamojska, M.
Śliwinska-Kowalska, M.
Powiązania:
https://bibliotekanauki.pl/articles/90038.pdf
Data publikacji:
2011
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
musicians
exposure to orchestral noise
risk of noise-induced hearing loss
Opis:
This study aimed to assess exposure to sound and the risk of noise-induced hearing loss (NIHL) in orchestral musicians. Sound pressure level was measured in 1 opera and 3 symphony orchestras; questionnaires were filled in. On the basis of that data, the risk of NIHL was assessed according to Standard No. ISO 1999:1990. Classical orchestral musicians are usually exposed to sound at equivalent continuous A-weighted sound pressure levels of 81−90 dB (10th−90th percentiles), for 20−45 h (10th−90th percentiles) per week. Occupational exposure to such sound levels over 40 years of employment might cause hearing loss (expressed as a mean hearing threshold level at 2, 3, 4 kHz exceeding 35 dB) of up to 26%. Playing the horn, trumpet, tuba and percussion carries the highest risk (over 20%).
Źródło:
International Journal of Occupational Safety and Ergonomics; 2011, 17, 3; 255-269
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Noise Exposure and Hearing Threshold Levels Among Call Centre Operators
Autorzy:
Pawlaczyk-Łuszczyńska, Małgorzata
Zamojska-Daniszewska, Małgorzata
Zaborowski, Kamil
Dudarewicz, Adam
Powiązania:
https://bibliotekanauki.pl/articles/176315.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
communication headsets
occupational exposure to noise
hearing threshold levels
hearing loss
noise-induced hearing loss
Opis:
The aim of this study was to evaluate the hearing status of call centre operators in relation to their noise exposure. Conventional pure-tone audiometry and extended high-frequency audiometry were performed in 49 workers, aged 22-47 years (mean ± SD: 32.0 ± 6.0 years), working in call centre from 1.0 to 16.5 years (mean ± SD: 4.7 ± 2.9 years). Questionnaire inquiry aimed at collecting personal data, the information on communication headset usage habits, self-assessment of hearing ability and identification of risk factors for noise-induced hearing loss were also carried out. Sound pressure levels generated by the communication headset were determined using the artificial ear technique specified in CSA Z107.56-13 (2013) standard. The background noise prevailing in offices was also measured according to PN-N-01307 (1994) and PN-EN ISO 9612 (2011). Personal daily noise exposure levels in call centre operators varied from 66 to 86 dB (10-90th percentile). About half of the study subjects had normal hearing in the standard frequencies (from 250 to 8000 Hz) in both ears, while only 27.1% in the extended high-frequencies (9-16 kHz). Moreover, both high-frequency and speech-frequency hearing losses were observed in less than 10% of audiograms, while the extended high-frequency threshold shift was noted in 37.1% of analysed ears. The hearing threshold levels of call centre operators in the frequency of 0.25-11.2 kHz were higher (worse) than the expected median values for equivalent (due to age and gender) highly screened population specified in ISO 7029 (2017). Furthermore, they were also higher than predicted for 500-4000 Hz according to ISO 1999 (2013) based on the results of noise exposure evaluation.
Źródło:
Archives of Acoustics; 2019, 44, 4; 747-759
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zasady zarządzania ryzykiem zawodowym związanym z narażeniem na nanoobiekty, ich aglomeraty i agregaty (NOAA)
Principles of occupational risk management related to exposure to nano-objects, their agglomerates and aggregates (NOAA)
Autorzy:
Jankowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/137727.pdf
Data publikacji:
2015
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
nanomateriały
nanoobiekty
powietrze na stanowiskach pracy
zasady zarządzania ryzykiem zawodowym
ocena narażenia
nano-objects
principles of occupational risk management
evaluation of exposure
Opis:
W artykule przedstawiono zasady zarządzania ryzykiem zawodowym i praktyczne rady dotyczące ich wdrożenia, zgodnie z zaleceniami przedstawionymi w specyfikacjach technicznych: ISO/TS 12901-1:2012 Nanotechnologies – Occupational risk management applied to engineered nanomaterials –Part 1. Principles and approaches i ISO/TS 12901-2:2014 Nanotechnologies – Occupational risk management applied to engineered nanomaterials – Part 2. Use of the control banding approach. Stwierdzono, że ponieważ obecnie brak jest powszechnie akceptowanych metod do oceny ryzyka zawodowego związanego z narażeniem na NOAA, których podstawą są dane pomiarowe określane w rzeczywistych warunkach narażenia, oraz wartości referencyjnych (dopuszczalnych) w odniesieniu do poszczególnych NOAA występujących w środowisku pracy, to w procesie zarządzania ryzykiem zawodowym związanym z narażeniem na NOAA może być stosowana metoda bazująca na ustalaniu kategorii zagrożenia (HB) i szacowaniu poziomu narażenia (EB) przedstawiona w specyfi kacji technicznej ISO/TS 12901-2.
The article presents principles of occupational risk management and practical advice on their implementation in accordance with the recommendations proposed in the technical specifications ISO/TS 12901-1:2012 Nanotechnologies – Occupational risk management applied to engineered nanomaterials – Part 1. Principles and approaches and ISO/TS 12901-2:2014 Nanotechnologies – Occupational risk management applied to engineered nanomaterials – Part 2. Use of the control banding approach. Because there are no commonly accepted methods to assess the occupational risks associated with exposure to NOAA, based on the measurement data determined in the real conditions of exposure, and reference values (limits) for each NOAA in the working environment method based on determining hazard category (HB) and estimating the level of exposure (EB) presented in ISO/TS 12901-2 can be used in the process of occupational risk management related to exposure to NOAA.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2015, 2 (84); 17-36
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of electronic device technology for measurement and evaluation of thermal exposure of fire fighters and members of rescue teams
Autorzy:
Bernatíková, Šárka
Tomášková, Hana
Bužga, Marek
Jirák, Zdeněk
Novák, Petr
Babjak, Ján
Kot, Tomáš
Krys, Václav
Jánošík, Ladislav
Powiązania:
https://bibliotekanauki.pl/articles/2162587.pdf
Data publikacji:
2017-12-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
heart rate
correlation
body temperature
fire fighter
physical strain
thermal load
Opis:
Background The work of members of rescue teams could be associated with very high physical and thermal loads. If not timely interrupted, any extreme labour-thermal load may lead to a failure of the body and fatal collapse. This risk may be significantly reduced by devices that monitor the response of the body during the intervention and inform rescuers about the need to interrupt the exposure when the critical value of the reference indicator is achieved. The aim of the study was to test the correlation between the data of the newly developed device for signaling the strain of rescuers and the indicators of physiological response of the body. Material and Methods The tests were performed on 2 physically fit fire fighters dressed in a protective rescue suit and using insulating breathing apparatus, over a wide range of heat load under a model load on a bicycle ergometer in a climatic chamber. Results The study provided a significant correlation between the body temperature measured in the ear canal and the temperature under the suit sensed by the tested device – the Safety Ambient Monitor (SAM) (R = 0.9007). The temperature under the suit also correlated with the temperature of the chest skin (R = 0.8928) and heart rate (R = 0.8613). Conclusions A statistically significant correlation was proven between the temperature sensed by the SAM and the body temperature. The technical solution of sensing the temperature under the suit using the verified SAM technology does not affect or limit fire fighters in their work and minimizes the possibility of damage to the sensor and signaling failures. Med Pr 2018;69(1):1–11
Źródło:
Medycyna Pracy; 2018, 69, 1; 1-11
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Harmonizacja strategii pomiarowych do oceny narażenia na: nanoobiekty, ich aglomeraty i agregaty (NO A A)
Harmonizing measurement strategies for assessing exposure to nano-objects and their agglomerates and aggregates (NOAA)
Autorzy:
Jankowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/138241.pdf
Data publikacji:
2014
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
nanotechnologie
nanomateriały
nanoobiekty
NOAA
powietrze na stanowiskach pracy
strategie pomiarowe
ocena narażenia
nanotechnology
nanomaterials
nano-objects
workplace air
measurement strategies
evaluation of exposure
Opis:
W artykule przedstawiono zagadnienia, które powinny być uwzględnione podczas harmonizacji metod pomiarów wykonywanych w rzeczywistych warunkach na stanowiskach pracy w kontekście oceny narażenia i ryzyka zawodowego oraz doboru właściwych środków ochrony. Stwierdzono, że istotnym zagadnieniem jest również harmonizacja w zakresie: analizowania, oceny i opracowywania sprawozdań dotyczących danych o narażeniu na: nanoobiekty, ich aglomeraty i agregaty (NOAA), podczas badań wykonywanych w rzeczywistych warunkach ich emisji na stanowiskach pracy oraz określenie trybu postępowania podczas kalibrowania aparatury pomiarowej stosowanej w badaniach emisji NOAA w czasie rzeczywistym. Bardzo ważnym działaniem, z uwagi na opracowywanie baz danych, jest przechowywanie informacji dotyczących narażenia na NOAA i oceny ryzyka zawodowego związanego z występowaniem NOAA w środowisku pracy. Informacje te mogą stanowić podstawę do przyszłego rozwoju, kalibracji i walidacji modeli narażenia lub budowania scenariuszy narażenia.
This article discusses harmonizing methods of measurements done in real conditions at workstations in the context of assessing exposure and occupational risk and selecting appropriate protection measures. It is important to harmonize the analysis, evaluation and reporting of data on exposure to nanoobjects during measurements done in real conditions and to determine procedures for calibrating equipment for measuring emission of nanoobjects in real time. In the context of the development of the database, it is also very important to store information on exposure to nanoobjects and on risk assessment related to the presence of nanoobjects in the working environment, 'lilis information can provide a basis for future development, calibration and validation of models or for building exposure scenarios.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2014, 4 (82); 7-21
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antropometryczne zróżnicowanie oddziaływania na pracownika radiofalowych pól elektromagnetycznych o częstotliwościach 100 MHz
Anthropometric differentiation of effects of radiofrequency electromagnetic fields of frequency 100 MHz on workers
Autorzy:
Zradziński, Patryk
Karpowicz, Jolanta
Gryz, Krzysztof
Leszko, Wiesław
Powiązania:
https://bibliotekanauki.pl/articles/2166236.pdf
Data publikacji:
2014-10-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
współczynnik SAR
symulacje numeryczne
korelacja
częstotliwości radiowe
zagrożenia elektromagnetyczne
zindywidualizowana ocena narażenia
SAR
numerical simulations
correlation
radiofrequency
electromagnetic hazards
individualized evaluation of exposure
Opis:
Wstęp: Współczynnik SAR (specific energy absorption rate), obliczany w wirtualnych modelach ciała człowieka, może być wykorzystany do oceny skutków termicznych oddziaływania radiofalowych pól elektromagnetycznych na ludzi. Modele te nie reprezentują cech antropometrycznych całej populacji. Istotne jest więc określenie zależności między wartościami SAR a cechami antropometrycznymi, co umożliwi zindywidualizowanie oszacowania SAR - niezależnie od cech budowy ciała danej osoby. Materiał i metody: Przeanalizowano 48 scenariuszy ekspozycji 4 wirtualnych modeli ciała (mężczyzny i kobiety) na pola elektromagnetyczne (27 MHz lub 100 MHz, polaryzacja pionowa i pozioma, różne kierunki propagacji). Wyniki: W podgrupie wyników dotyczących pola 100 MHz/polaryzacja pionowa stwierdzono istotne statystycznie (silne, p < 0,05) korelacje: między SAR uśrednionym w całym ciele a wzrostem, masą ciała, wskaźnikiem masy ciała, obwodem klatki piersiowej, pasa lub szyi i powierzchnią przekroju w płaszczyźnie czołowej; między miejscowym SAR w głowie lub szyi a wzrostem, masą ciała, obwodem klatki piersiowej, szyi i powierzchnią przekroju w płaszczyźnie czołowej. Wykorzystując zidentyfikowane powiązania i SAR w modelu Gustav, oszacowano zróżnicowanie w populacji dorosłych Polaków (5-95. centyla kobiet i mężczyzn): ±30% dla SAR uśrednionego w całym ciele i ±50% dla SAR miejscowych. Wnioski: Wykazano, że dokonując wstępnej klasyfikacji ocenianego rodzaju ekspozycji na radiofalowe pole elektromagnetyczne (np. pod względem polaryzacji i częstotliwości), można zidentyfikować powiązania statystyczne między wartościami różnych współczynników SAR a cechami antropometrycznymi organizmu. Wielkości powiązane można wykorzystać do zindywidualizowania oceny narażenia pracowników na pola elektromagnetyczne. Med. Pr. 2014;65(3):351–360
Background: Thermal effects of radiofrequency electromagnetic fields (REMF) exposure of humans may be assessed by calculations of the parameter recognized as SAR (specific energy absorption rate) in virtual human body models, which actually do not represent anthropometric properties of the entire population. Therefore, it is important to determine the relations between SAR values and anthropometric parameters that enable individualization of SAR estimation independently of body properties of a given person. Material and Methods: The analysis concerned 48 exposure scenarios of 4 virtual body models (male and female) to vertically or horizontally polarized REMF of 27 MHz or 100 MHz frequency of various directions of propagation. Results: In the subgroup of results 100 MHz / vertical polarization statistically significant (strong; p < 0.05) correlations were identified between SAR averaged in the whole body and height, mass, BMI, circumference of chest, waist, neck and frontal cross-section area, and between local SAR in head and neck and the height, mass, circumference of chest waist or neck and frontal cross-section area. Identified relations and SAR in the Gustav model were used to estimate the variety of SAR in Polish population of adults (5-95. percentile of female and male): ±30% for SAR averaged in the whole body, ±50% for localized SAR. Conclusions: It was demonstrated that in the preliminary classified type of assessed REMF exposure (e.g., in terms of field polarization and frequency) it is possible to identify statistical relations between various SAR parameters and anthropometric properties of the exposed body. Related quantities can be used for individualized assessment of worker's electromagnetic hazards. Med Pr 2014;65(3):351–360
Źródło:
Medycyna Pracy; 2014, 65, 3; 351-360
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of internal exposure of nuclear medicine staff working with radioiodine in Poland
Autorzy:
Krajewska, Grażyna
Krajewski, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/21375376.pdf
Data publikacji:
2023-11-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
nursing
medical imaging
radionuclide imaging
radiation effects
radioisotope therapy
radioisotope scanning
Opis:
The iodine-131 (I-131) content in the thyroid of staff members working with this radionuclides has been measured with about 500 employees in about 25 hospital’s departments of nuclear medicine performing therapy and diagnosis of thyroid disease in Poland. The measurements were performed with portable detection unit for in situ measurements of radioiodine. This is consist with scintillation detector sodium iodine activated by thallium (NaI(Tl)) – battery-powered and portable tube base Multichannel Analyzer Canberra UniSPEC. Based on direct measurements of the iodine content, the effective dose equivalent for workers due to inhalation of I-131 was estimated. All individuals actively working with iodine show measurable amounts of this isotopes in their thyroids. The average measured activity in the thyroid of the nuclear medicine staff was found to be equal at average 550 Bq within the range 70 Bq–2.5 kBq. There is no apparent correlation between the measured I-131 levels and risk categories. Nevertheless the technical and nuclear medicine staff show higher I-131 thyroid level comparing to hospital services staff. Calculated maximum committed effective dose for particular exposed person is <10% of 20 mSv/year.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2023, 36, 5; 587-595
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of exposure of the operators on the contact with the plant protection products during the spraying process
Ocena narażenia operatorów na kontakt ze środkami ochrony roślin podczas przeprowadzania zabiegów opryskiwania
Autorzy:
Brennensthul, Marek
Cieniawska, Beata
Czarnecki, Jarosław
Ptak, Weronika
Powiązania:
https://bibliotekanauki.pl/articles/1333467.pdf
Data publikacji:
2020-12-31
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
plant protection
spraying
personal protective equipment
ochrona roślin
opryskiwanie
środki ochrony osobistej
Opis:
Plant protection products are one of the most dangerous substances in the agricultural working environment. The application of plant protection products by the broken implements or by wrong techniques can create the threats both for the operators, other people and for natural environment. The objective of this research was the evaluation of exposure of the sprayer operator on the liquid spray. Research was conducted for two types of the manual handling sprayers (backsprayer and shoulder-sprayer). To evaluate the exposure level the water-sensitive papers were used – they were placed on the elements of the workwear and personal protective equipment of operators. It was conclude that the highest exposure concerned the upper limbs (especially forearms) and the chest. Moreover, on the flat crop higher exposure on the liquid spray was observed for the shoulder-sprayer while on the orchard crop the differences between the sprayers in aspect of expo-sure were insignificant.
Środki ochrony roślin są jednymi z najniebezpieczniejszych substancji w rolniczym środowisku pracy. Aplikacja środków ochrony roślin przy użyciu niesprawnego sprzętu lub nieprawidłową techniką może stanowić zagrożenie dla osoby wykonującej opryskiwanie, dla osób postronnych oraz dla środowiska naturalnego. Celem pracy była ocena narażenia opera-tora opryskiwacza na kontakt z cieczą roboczą przy wykonywaniu zabiegu opryskiwania. Badania przeprowadzono dla dwóch typów opryskiwaczy ręcznych: plecakowego i biodrowego. Do oceny stopnia narażenia wykorzystano papierki wodoczułe, które umieszczono na elementach odzieży roboczej i środkach ochrony indywidualnej operatora. Wykazano, że największe narażenie na kontakt z cieczą użytkową dotyczyło kończyn górnych (zwłaszcza przedramion) oraz klatki piersiowej. Ponadto wykazano, że podczas zabiegu na uprawie płaskiej większe narażenie na kontakt z cieczą wystąpiło przy użyciu opryskiwacza biodrowego, zaś przy opryskiwaniu uprawy sadowniczej nie stwierdzono istotnego wpływu typu opryskiwacza na pokrycie ciała operatora cieczą użytkową.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2020, 65, 2; 4-8
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Workers’ Exposure to Methylene Diphenyl Diisocyanate (MDI) in an Automobile Manufacturing Company, Iran
Autorzy:
Kakooei, H.
Shahtaheri, S. J.
Karbasi, H.- A.
Powiązania:
https://bibliotekanauki.pl/articles/90901.pdf
Data publikacji:
2006
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
occupational exposure
MDI
respiratory symptoms
spectrophotometer
spirometer
zagrożenia chemiczne
przemysł motoryzacyjny
Iran
spirometria
narażenie zawodowe
Opis:
Evaluation of personal inhalation exposure to methylene diphenyl diisocyanate (MDI) among 39 employees, working in the window fixation and window glue processes in an automobile manufacturing company was performed. This study was conducted for both case and control groups. After sampling and sample preparation processes, MDI was determined with a UV-VIS spectrophotometer at 590 nm; the lung function was assessed with a digital spirometer, too. The average concentration of MDI in the window fixation, and window glue workplaces were 34.53 and 27.37 μg/m3, respectively, which was lower than the threshold limit value (TLV) recommended by the American Conference of Governmental Industrial Hygienists (ACGIH) (51 μg/m3). Respiratory symptoms in the exposed group were significantly different compared to the unexposed group (p < .05). Lung capacities in the case group were lower than in the control group (p < .05). Therefore, MDI can be easily measured making it possible to evaluate the adverse effects caused by occupational exposure.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2006, 12, 4; 443-449
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory evaluation of occupational exposure to hand-arm vibration (HAV) during grounds maintenance equipment operations
Autorzy:
Oh, J.
Chen, N.
Boyd, C.
Powiązania:
https://bibliotekanauki.pl/articles/28762628.pdf
Data publikacji:
2023
Wydawca:
Instytut Medycyny Wsi
Źródło:
Annals of Agricultural and Environmental Medicine; 2023, 30, 2; 384-389
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Risk evaluation of driver exposure to exhaust fumes inside the passenger car cabin in urban traffic conditions
Autorzy:
Skrętowicz, M.
Jankowski, A.
Haller, P.
Woźniak, J.
Janas, M.
Powiązania:
https://bibliotekanauki.pl/articles/245464.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
vehicles
road transport
air pollution
car cabin
volatile organic compounds (VOCs)
Opis:
Nowadays, with the current dynamic development of the automotive industry, we spend more and more time indoors, including in vehicles. The air used for ventilation of the vehicle's cabin comes from the outside. Pollution enters into the vehicle. This research presents the results of tests conducted to assess the exposure of the driver and passengers to volatile organic compounds entering the vehicle with atmospheric air. The simulation researches were conducted on a chassis dynamometer at the Department of Vehicle Engineering at the Faculty of Mechanical Engineering Technical University of Wroclaw and the tests under real conditions, i.e. traffic urban conditions, were taken as well. The measurements were conducted in the centre of Wroclaw during peak hours, when the traffic jam is the most frequent. The measurements were taken in order to organic compounds analysis, which includes gas chromatography. The analysis results were averaged from three measurements to get these studies more reliable. Results show that during mobile tests the vehicle was exposed to much more pollution than in the stationary tests in the simulated conditions of traffic congestion. Therefore, the studies present that the pollution in the traffic congestion is the real danger to drivers.
Źródło:
Journal of KONES; 2016, 23, 3; 457-464
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Środki ochrony roślin a zdrowie rolników – biomarkery oraz możliwości ich wykorzystania do oceny ekspozycji na pestycydy
Plant protection products and farmers’ health – perspectives of the application of biomarkers for evaluation of exposure to pesticides and its biological eff ects
Autorzy:
Kapka-Skrzypczak, L.
Cyranka, M.
Kruszewski, M.
Turski, W.A.
Powiązania:
https://bibliotekanauki.pl/articles/941328.pdf
Data publikacji:
2011
Wydawca:
Instytut Medycyny Wsi
Tematy:
pestycydy fosfoorganiczne
biomarkery narażenia
biomarkery skutków
genotoksyczność
Opis:
Pestycydy to substancje syntetyczne lub naturalne stosowane do zwalczania organizmów szkodliwych lub niepożądanych. Wśród obecnie stosowanych insektycydów najbardziej niebezpieczne, ze względu na ryzyko ostrych zatruć, są związki fosforoorganiczne. Jednak także długotrwała ekspozycja na toksyczne działanie pestycydów w najbliższym otoczeniu lub środowisku pracy niesie ze sobą ryzyko zdrowotne. Stopień narażenia środowiskowego i zawodowego na działanie insektycydów fosfoorganicznych może być monitorowany za pomocą biologicznych wskaźników oceniających ekspozycję, ryzyko zdrowotne czy osobniczą wrażliwość na toksyczne działanie tych pestycydów. Praca przedstawia najczęściej stosowane biomarkery wczesnych skutków biologicznych ekspozycji na pestycydy fosfoorganiczne, ze szczególnym naciskiem na genotoksyczne skutki powodowane narażeniem na te związki. Podsumowuje również możliwości i ograniczenia, jakie posiadają biomarkery wykorzystywane do oceny i identyfi kacji ekspozycji środowiskowej/zawodowej na działanie pestycydów.
Źródło:
Medycyna Ogólna i Nauki o Zdrowiu; 2011, 17(46), 1; 29-32
2083-4543
Pojawia się w:
Medycyna Ogólna i Nauki o Zdrowiu
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of occupational exposure to wood dust among sawmill workers within the Gert Sibande District Municipality, South Africa
Autorzy:
Rathipe, M.
Raphela, F.S.
Powiązania:
https://bibliotekanauki.pl/articles/28761740.pdf
Data publikacji:
2022
Wydawca:
Instytut Medycyny Wsi
Źródło:
Annals of Agricultural and Environmental Medicine; 2022, 29, 4; 483-488
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanoobiekty
Nano-objects at workplaces
Autorzy:
Jankowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/137997.pdf
Data publikacji:
2011
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
nanotechnologie
nanomateriały
nanoobiekty
powietrze na stanowiskach pracy
ocena potencjalnego narażenia
nanotechnology
nanomaterials
nano-objects
evaluation of potential exposure
Opis:
W artykule przedstawiono niektóre zagadnienia związane z nanoobiektami (nazwa zwyczajowa: nanocząstki) i metodami badania ich parametrów. Podano definicje, przepisy prawne i normy oraz projekty badawcze ukierunkowane na uzyskanie wyników związanych z rzeczywistym narażeniem na nanoobiekty. Przedstawiono także przykładowe podejście do oceny potencjalnego narażenia na nanoobiekty występujące w środowisku pracy.
In the article some issues connected with nanoobjects (vernacular of the "nanoparticles") and methods of investigation of nanoobjects parameters were presented. Definitions, provisions of law and norms and research projects directed at achieving results associated with real exposure to nanoobjects were given. An also model attempt at the evaluation of potential exposure to nanoobjects in a workplace was described.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2011, 4 (70); 7-20
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of occupation hot exposure in industrial workplaces in a subtropical country
Autorzy:
Yang, Yu-Chiao
Wei, Ming-Chi
Hong, Show-Jen
Powiązania:
https://bibliotekanauki.pl/articles/2161875.pdf
Data publikacji:
2017-05-08
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
skin temperature
heart rate
heat stress
wet bulb globe temperature
maximum allowable exposure time
metabolic rate
Opis:
Objectives The objective of this study has been to evaluate the occupational heat exposure of 12 workers at 5 plants in a subtropical country. Material and Methods The heat stresses and strain on workers in 5 plants were assessed by the International Organization for Standardization (ISO) 7243 index (wet bulb globe temperature – WBGT) and the ISO 7933 index (maximum allowable exposure time – $ \text{D}_\text{lim} $). Results Results indicated that 42% of the subjects (5 workers) surpassed the WBGT limits. According to the $ \text{D}_\text{lim} $, 42% of the subjects could not continue working in the hot environments. The relationships between the various heat stress indices and the WBGT index were also correlated. However, further studies from different heat environments and more subjects should be performed. Conclusions The sensitive dependence of skin temperature on meteorological and physiological indices for each subject was clearly observed. Obviously, the heart rate response to metabolic rate was much greater than that caused by environmental heat alone. The exponential relationship between workers’ duration-limited exposure time, predicted by various estimated criteria, and WBGT were also found. Int J Occup Med Environ Health 2017;30(3):379–395
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 3; 379-395
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Solid Phase Extraction for Evaluation of Occupational Exposure to Pb (II) Using XAD-4 Sorbent Prior to Atomic Absorption Spectroscopy
Autorzy:
Shahtaheri, S. J.
Khadem, M.
Golbabaei, F.
Rahimi-Froushan, A.
Ganjali, M. R.
Norouzi, P.
Powiązania:
https://bibliotekanauki.pl/articles/90822.pdf
Data publikacji:
2007
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
lead
sample preparation
atomic absorption spectroscopy
Opis:
Lead is an important constituent widely used in different industrial processes. For evaluation of workers’ exposure to trace toxic metal of Pb (II), solid-phase extraction (SPE) was optimized. SPE using mini columns filled with XAD-4 resin was developed with regard to sample pH, ligand concentration, loading flow rate, elution solvent, sample volume, elution volume, the amount of resins, and sample matrix interferences. Lead ions were retained on a solid sorbent and then eluted, followed by a simple determination of analytes with flame atomic absorption spectrometery. The obtained recoveries of metal ions were greater than 92%. This method was validated with 3 different pools of spiked urine samples; it showed a good reproducibility over 6 consecutive days as well as 6 within-day experiments. This optimized method can be considered successful in simplifying sample preparation for a trace residue analysis of lead in different matrices when evaluating occupational and environmental exposures is required.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2007, 13, 2; 137-145
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Określenie narażenia osób biegających w wybranych punktach Krakowa na aerozol mikrobiologiczny
Evaluation of runners exposure to microbial aerosol in selected sites in Cracow
Autorzy:
Wolny-Koładka, Katarzyna
Szatan, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/1177580.pdf
Data publikacji:
2015
Wydawca:
Instytut Medycyny Wsi
Tematy:
"Kraków"
"bieganie"
"bioaerozol"
"mikroorganizmy"
"powietrze"
Opis:
Introduction. The purpose of this study was to evaluate the microbiological quality of the air at the selected places which are located in Cracow and also to determine the influence of weather conditions, such as temperature, humidity and pollination on the number of microorganisms. Material and methods. Samples of air were taken during spring, summer, autumn and winter. The analyses were carried out by using a single-stage MAS-100 impactor (Merck) and repeated three times. Results were compared to guidelines which are included in Polish Standards. Results. The results of the study suggest that there is correlation between seasons and number of microorganisms. Moreover the number of microbes depends on location. The highest concentration of all groups of microorganisms occurred in summer and autumn. Conversely the lowest number of microbes occurred in winter. The results indicated that the composition of bioaerozol is typical and consists of fungi: Cladosporium spp., Mucor spp., Penicillium spp., Alternaria spp., Trichothecium spp., Fusarium spp., bacteria: Micrococcus spp., Diplococcus spp., Tetracoccus spp., Streptobacillus spp., Staphylococcus spp. and actinomycetes. Conclusions. The results revealed that there is a big difference in the occurence of microorganisms and it depends on season and location as well. However our study indicates that air does not pose a microbiological threat to runners.
Wstęp. Celem pracy była ocena jakości mikrobiologicznej powietrza w wybranych punktach zlokalizowanych na terenie Krakowa. Określono także wpływ warunków meteorologicznych: temperatury, wilgotności oraz zapylenia na liczebność drobnoustrojów. Materiał i metody. Powietrze do badań pobierano wiosną, latem, jesienią i zimą 2014 r., metodą uderzeniową przy użyciu impaktora typu MAS-100 (Merck). Analizę wykonano w trzech powtórzeniach, wyniki porównano z wytycznymi zawartymi w Polskich Normach. Wyniki. Stwierdzono zależność między porą roku a liczebnością badanych drobnoustrojów stanowiących bioaerozol. Ich liczebność różniła się również w zależności od punktu poboru. Lato i jesień okazały się być porami roku, w czasie których wszystkie badane grupy mikroorganizmów występowały w powietrzu w największym stężeniu. Natomiast zima okazała się być najmniej sprzyjającą porą roku dla drobnoustrojów. Wbadanych próbkach stwierdzono występowanie typowej mikroflory powietrza. Zidentyfikowano grzyby należące do rodzajów: Cladosporium, Mucor, Penicillium, Alternaria, Trichothecium i Fusarium. Wśród bakterii zidentyfikowano Micrococcus spp., Diplococcus spp., Tetracoccus spp., Streptobacillus spp., Staphylococcus spp. oraz promieniowce. Wnioski. Stwierdzono, duże zróżnicowanie w występowaniu drobnoustrojów w zależności od pory roku i punktu poboru powietrza. Przeprowadzone badania wykazały, że powietrze w badanych lokalizacjach nie stanowiło zagrożenia mikrobiologicznego dla osób biegających.
Źródło:
Medycyna Środowiskowa - Environmental Medicine; 2015, 18, 2; 39-47
1505-7054
2084-6312
Pojawia się w:
Medycyna Środowiskowa - Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena narażenia środowiskowego na Cr, Cu, Pb, Ni oraz Zn obecne w pyłach miejskich
Evaluation of environmental exposure to Cr, Cu, Pb, Ni and Zn present in urban dusts
Autorzy:
Trojanowska, M.
Świetlik, R.
Powiązania:
https://bibliotekanauki.pl/articles/372656.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
ryzyko zdrowotne
metale ciężkie
indeks zagrożenia
health risk
heavy metals
hazard index
Opis:
W pracy dokonano oceny narażenia środowiskowego mieszkańców miast na metale ciężkie, obecne w pyłach miejskich. Badania skoncentrowano na całożyciowym narażeniu osoby dorosłej oraz dziecka na Cr, Pb, Ni, Cu i Zn. W ocenie ryzyka zdrowotnego uwzględniono narażenie drogą pokarmową, inhalacyjną i dermalną. Szacowanie zagrożeń przeprowadzono w oparciu o metodę zalecaną przez Amerykańską Agencję Ochrony Środowiska (US EPA). Wyznaczone wartości indeksów zagrożenia, charakteryzujących ryzyko zdrowotne wykazały, że największe zagrożenie występuje na skutek przypadkowego wprowadzania substancji toksycznych drogą pokarmową. W mniejszym stopniu o zagrożeniu decyduje wnikanie metali przez skórę człowieka, natomiast w najmniejszym wnikanie drogą inhalacyjną. Zgodnie z przyjętym scenariuszem narażenia mieszkańca bardziej zagrożoną populacją są dzieci, dla których uzyskano większe wartości indeksów zagrożenia.
The paper assesses the environmental exposure of urban dwellers to heavy metals present in urban dusts. The research was focused on lifelong exposure of an adult and a child to chromium, lead, nickel, copper and zinc. The assessment of health hazard included exposure by digestion, inhalation and skin contact. The hazard estimation was carried out using a method recommended by the American Environmental Protection Agency (US EPA). The determined hazard index values characterizing a health risk have shown that the highest hazard results from accidental unintentional intake of toxic substances. Skin penetration by metals is much less hazardous, whereas inhalation is least hazardous. According to the accepted scenario of human exposure, children are most at risk compared to other populations considered. The hazard index values obtained for them were the highest.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2017, 167 (47); 88-100
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena narażenia na hałas i ryzyko uszkodzenia słuchu u pracowników używających słuchawkowych zestawów komunikacyjnych lub słuchawek
Evaluation of noise exposure and risk of hearing impairment in employees using communication headsets or headphones
Autorzy:
Pawlaczyk-Łuszczyńska, Małgorzata
Zaborowski, Kamil
Zamojska-Daniszewska, Małgorzata
Dudarewicz, Adam
Rutkowska-Kaczmarek, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/2162599.pdf
Data publikacji:
2019-02-28
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
ekspozycja zawodowa
hałas
uszkodzenie słuchu
pomiar hałasu
szacowanie ryzyka
słuchawkowe zestawy komunikacyjne
occupational exposure
noise
hearing loss
noise measurement
risk assessment
communication headsets
Opis:
Wstęp Celem pracy była ocena narażenia na hałas i ryzyka uszkodzenia słuchu spowodowanego hałasem wśród użytkowników słuchawkowych zestawów komunikacyjnych lub słuchawek. Materiał i metody W grupie 74 pracowników (wiek: 31,8±7,3 roku), w tym personelu lotnictwa wojskowego (N = 12), transkrybentów (N = 18) i telemarketerów (N = 44), przeprowadzono pomiary hałasu i badania kwestionariuszowe. Poziomy dźwięku emitowanego przez słuchawkowe zestawy komunikacyjne (lub słuchawki) zmierzono z zastosowaniem techniki microphone in the real ear (MIRE) i techniki sztucznego ucha, odpowiednio, według norm PN-EN ISO 11904-1:2008 i CSA Z107.56-13. Ryzyko uszkodzenia słuchu wywołanego hałasem oszacowano zgodnie z wytycznymi normy PN-ISO 1999:2000. Wyniki Mierzone pod słuchawkami i słuchawkowymi zestawami komunikacyjnymi z zastosowaniem technik MIRE i sztucznego ucha wartości równoważnego poziomu dźwięku A (odpowiadającego warunkom pola rozproszonego) wynosiły, odpowiednio, 67–86 dB (10–90 percentyl) i 68–89 dB (10–90 percentyl). Badani pracownicy używali tych urządzeń średnio przez 1,5–8 godz. dziennie (10–90 percentyl). Ekspozycja na takie poziomy dźwięku przez 40 lat pracy wiąże się z ryzykiem uszkodzenia słuchu (średni próg słuchu dla częstotliwości 2, 3 i 4 kHz > 25 dB) sięgającym 10–12% (technika MIRE) lub 19–22% (technika sztucznego ucha). Wartości indywidualnego dziennego poziomu ekspozycji na hałas w badanej grupie wynosiły 71–85 dB (10–90 percentyl). Część pracowników skarżyła się na problemy z rozumieniem mowy w hałaśliwym otoczeniu (28,4%) i słyszeniem szeptu (16,2%) oraz zauważyła przejściowe skutki słuchowe po pracy z zastosowaniem słuchawkowych zestawów komunikacyjnych lub słuchawek (16,2–25,7%). Wnioski Wskazane jest objęcie użytkowników słuchawkowych zestawów komunikacyjnych i słuchawek programem ochrony słuchu oraz kontynuowanie badań wśród pracowników innych branż. Med. Pr. 2019;70(1):27–52
Background The aim of the study was to assess the noise exposure and risk of noise-induced hearing loss (NIHL) among users of communication headsets (CHs) or headphones. Material and Methods Noise measurements and questionnaire surveys were carried out in 74 workers (aged: 31.8±7.3 years), including military aviation personnel (N = 12), transcribers (N = 18) and call center operators (N = 44). Sound pressure levels (SPLs) emitted by CHs (or headphones) were determined using the microphone in the real ear (MIRE) technique and artificial ear techniques according to PN-EN ISO 11904-1:2008 and CSA Z107.56-13, respectively. The risk of NIHL was evaluated in accordance with PN-ISO 1999:2000. Results The diffused-field-related A-weighted equivalent-continuous SPLs measured under CHs (or headphones) using the MIRE and artificial ear techniques reached values of 67–86 dB (10–90th percentile) and 68–89 dB (10–90th percentile), respectively. The study subjects used these devices 1.5–8 h (10–90th percentile) per day. Exposure to such noise levels for 40 years of employment causes the risk of hearing impairment (mean hearing threshold level for 2, 3 and 4 kHz > 25 dB) up to 10–12% (MIRE technique) or 19–22% (artificial ear technique). Individual daily noise exposure levels in study group varied 71–85 dB (10–90th percentile). A number of workers complained of problems with understanding speech in noisy environment (28.4%) and hearing whisper (16.2%) and experienced post-work temporary hearing symptoms (16.2–25.7%) as well. Conclusions The users of CHs and headphones should be included in the hearing conservation program. Further studies are also needed among employees of other industries. Med Pr. 2019;70(1):27–52
Źródło:
Medycyna Pracy; 2019, 70, 1; 27-52
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena narażenia na ołów mieszkańców wybranych rejonów legnicko-głogowskiego okręgu miedziowego (LGOM) metodą wskaźnikową
Evaluation of lead exposure in inhabitants of certain areas of the Legnica-Głogów copper mining district by the indicator method
Autorzy:
Gzyl, J.
Kucharski, R.
Marchwinska, E.
Powiązania:
https://bibliotekanauki.pl/articles/873883.pdf
Data publikacji:
1984
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Źródło:
Roczniki Państwowego Zakładu Higieny; 1984, 35, 5
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przegląd metod oceny osobistej ekspozycji na zanieczyszczenia pyłowe powietrza w środowisku miejskim stosowanych w badaniach epidemiologicznych
REVIEW OF METHODS FOR EVALUATION OF PERSONAL EXPOSURE TO PARTICULATE AIR POLLUTION IN URBAN ENVIRONMENT USED IN EPIDEMIOLOGICAL RESEARCH
Autorzy:
Gayer, Anna
Powiązania:
https://bibliotekanauki.pl/chapters/2231666.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ekspozycja osobista
pył zawieszony PM 2
5
badania epidemiologiczne
Opis:
Tradycyjnie, w badaniach epidemiologicznych, osobista ekspozycja na pył zawieszony oceniana była na podstawie pomiarów prowadzonych przez sieć monitoringu powietrza i przez oszacowanie narażenia całej populacji przy użyciu modelowania matematycznego rozprzestrzeniania się zanieczyszczeń atmosferycznych. Wraz z postępem technologicznym wzrósł dostęp do zaawansowanych urządzeń do monitorowania jakości powietrza i opracowano szereg metod oceny osobistej ekspozycji na zanieczyszczenia pyłowe powietrza mieszkańców miast. W niniejszym artykule zaprezentowano wybrane metody oceny narażenia osobistego na pyłowe zanieczyszczenia powietrza obecne w środowisku miejskim powszechnie stosowane m.in. w naukach medycznych do analizy ich wpływu na zdrowie ludzkie. Wśród opisanych metod znajdują się: szacowanie narażenia na podstawie wyników pomiarów prowadzonych przez stacje monitoringu powietrza, pomiarów prowadzonych w określonych lokalizacjach, czy też za pomocą przenośnych pyłomierzy. W artykule opisano również modelowanie imisji zanieczyszczeń pyłowych metodą przestrzennej regresji.
Traditionally, in epidemiological studies, personal exposure was estimated using spatial interpolation based on measurements from fixed air monitoring stations. Technology development has increased access to advanced equipment for the air quality monitoring and brought a number of methods for assessing personal exposure to particulate air pollution in cities. This article presents selected methods for assessing personal exposure to particulate air pollution in urban environments used in the medical sciences to analyze their impact on human health.
Źródło:
Interdyscyplinarne zagadnienia w inżynierii i ochronie środowiska 6; 156-163
9788374938976
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie i ocena narażenia operatora podwieszanej zgrzewarki rezystancyjnej na jednoczesne oddziaływanie czynników elektromagnetycznego i biomechanicznego
The modeling and evaluation of the exposure of the workers operating suspended resistance welders to the simultaneous electromagnetic and biomechanical factors
Autorzy:
Zradziński, P.
Powiązania:
https://bibliotekanauki.pl/articles/262099.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
pole elektromagnetyczne
indukowane pole elektryczne
zgrzewarki rezystancyjne
symulacja numeryczna
układ mięśniowo-szkieletowy
electromagnetic field
induced electric field
resistance welders
numerical simulation
musculoskeletal system
Opis:
Ocena narażenia operatorów podwieszanych zgrzewarek rezystancyjnych na jednoczesne oddziaływanie czynników elektromagnetycznego i biomechanicznego jest zagadnieniem złożonym ze względu na przeciwstawne wymagania bezpieczeństwa i higieny pracy w tym zakresie. W artykule przeanalizowano zależność wartości miar wewnętrznych skutków ekspozycji na pola elektromagnetyczne i obciążenia układu mięśniowo- szkieletowego od pozycji ciała operatora urządzenia i sposobu wykonywania pracy. Badania wykazały znaczny rozrzut wartości parametrów w zależności od pozycji ciała i położenia głowicy zgrzewarki względem ciała pracownika. Najmniejsze narażenie pracownika na jednoczesne oddziaływanie czynników elektromagnetycznego i biomechanicznego występuje w pozycji wyprostowanej z opuszczoną lewą kończyną dolną. Największe narażenie łączne pojawia się wtedy, gdy ciało pracownika jest pochylone, a kończyny uniesione.
The evaluation of simultaneous electromagnetic and biomechanical factors affecting the workers operating suspended resistance welders is complex, due to the opposite requirements of the occupational safety and health, concerning these factors. The paper described examination of the dependence between the internal measures of electromagnetic field and musculoskeletal system load and the influence on the posture of the operator of the suspended gun for resistance welding. The results revealed the high variability of the level of measured parameters, depending on both: the workers’ posture and the resistance gun location with respect to the body of the operator. The lowest exposure to electromagnetic and biomechanical factors was found for upright position with the left upper limb bend dawn. The highest exposure was found for flexed posture and raised limbs.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2012, 18, 1; 50-54
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy oceny narażenia człowieka na drgania miejscowe w przypadku użycia rękawic i zastosowania metod konwencjonalnej oraz energetycznej
Problems of evaluation of human exposure to hand-arm vibrations in case of using gloves based on application of conventional and energy methods
Autorzy:
Hermann, T.
Dobry, M. W.
Powiązania:
https://bibliotekanauki.pl/articles/202529.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
system biomechaniczny
metoda energetyczna
rękawica
biomechanical system
energy method
glove
Opis:
W pracy przedstawiono porównanie wyników oceny narażenia człowieka na drgania miejscowe w przypadku zastosowania rękawic. Analizowany przypadek oceniono dwoma metodami, tzn. metodą konwencjonalną (z uwzględnieniem kryterialnego przyspieszenia drgań) i metodą energetyczną (wykorzystując wartości składników energii związanych z człowiekiem). Analizy przeprowadzono na podstawie wyników badań teoretycznych w systemie biodynamicznym człowiek - zmechanizowane narzędzie ręczne. W tym celu wykorzystano modele człowieka i rękawicy określone w normie ISO 10068:2012. Przeprowadzona analiza wykazała, że każda z metod daje inne wyniki oceny wpływu rękawic na ochronę człowieka. W artykule przedstawiono analityczne rezultaty i różnice w ocenie narażenia człowieka na drgania miejscowe otrzymane obiema metodami dla przykładowej sytuacji pracy operatora z wykorzystaniem zmechanizowanego narzędzia ręcznego.
The article presents a comparison of the results of human exposure to hand-arm vibration in case of using gloves. The analyzed case was assessed by two methods, i.e., performed by conventional method (including the criterion of accelerations of vibrations) and energy method (based on the dose of energy flowing through the human during the operation of the tool). The analyzes were based on the results of the theoretical studies of biodynamics and energy flow in the human - tool system. The models of the human and the glove, specified in the ISO 10068:2012 standard, were used for this purpose. The analysis showed that results of the evaluation of the impact of gloves on human protection obtained between both methods are different. The article presents the analytical results and differences in the assessment of human exposure to hand-arm vibrations, using both methods, as an example for a situation, in which an operator works with mechanized handheld tool.
Źródło:
Zeszyty Naukowe Politechniki Poznańskiej. Organizacja i Zarządzanie; 2018, 78; 35-50
0239-9415
Pojawia się w:
Zeszyty Naukowe Politechniki Poznańskiej. Organizacja i Zarządzanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zobiektywizowana ocena narażenia chirurgów na radiofalowe pola elektromagnetyczne – w kontekście czasu narażenia oraz polskich i znowelizowanych międzynarodowych wymagań dotyczących ochrony pracowników
Objectivized evaluation of surgeons exposure to radiofrequency electromagnetic fields – In the context of exposure duration and polish and new international requirements regarding workers protection
Autorzy:
Karpowicz, Jolanta
Gryz, Krzysztof
Leszko, Wiesław
Zradziński, Patryk
Powiązania:
https://bibliotekanauki.pl/articles/2166787.pdf
Data publikacji:
2014-11-04
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
ekspozycja zawodowa
pole elektryczne
dyrektywa Europejska 2013/35/UE
urządzenia medyczne
occupational exposure
electric field
European Directive 2013/35/EU
medical devices
Opis:
Wstęp: Wykorzystanie diatermii chirurgicznej w zabiegach operacyjnych związane jest z emisją pola elektromagnetycznego, które podlega ocenie ze względu na wymagania przepisów bezpieczeństwa i higieny pracy. Materiał i metody: Monitoring charakterystyki narażenia chirurgów wykonano w czasie 11 operacji (resekcja: odbytnicza, wątroby, guza pęcherza moczowego, migdałków, udrożnienie tętnicy i zabiegi laparoskopowe), wykorzystując rejestrator czasu rzeczywistej aktywności monopolarnych diatermii chirurgicznych w czasie zabiegów. Wykonano również badania wartości skutecznej natężenia pola elektrycznego i magnetycznego przy różnych trybach pracy urządzeń (moc: 55-150 W, częstotliwość: 330-445 kHz przy cięciu; 40-240 W, 335-770 kHz przy koagulacji). Dla każdej operacji oceniono parametry statystyczne rozkładu czasu użycia diatermii w okresie dowolnych 6 min (zgodnie z międzynarodowymi zaleceniami dotyczącymi ochrony przed niepożądanymi skutkami termicznymi oddziaływania pola elektromagnetycznego). Wyniki: Natężenie pola elektrycznego, zmierzone 10 cm od kabla zasilającego elektrodę czynną, wynosiło 147-675 V/m przy cięciu i 297-558 V/m przy koagulacji, a magnetycznego nie przekraczało 0,2 A/m przy obu trybach. Monitoring pracy diatermii w czasie operacji wykazał ich wykorzystanie w zakresie 5-66% czasu w ciągu początkowych 3 min zabiegu, 3-40% - w ciągu początkowych 6 min. Rozkład współczynnika ich wykorzystania podczas dowolnych 6-minutowych okresów charakteryzuje zakres: 0-12% (mediana) / 7-43% (wartość maksymalna). Wnioski: Rzeczywisty czas użycia diatermii chirurgicznej w czasie zabiegów jest zdecydowanie krótszy niż deklarowany przez pracowników. Przy co najmniej 15-centymetrowej odległości pracowników od kabli łączących elektrody z generatorem wymagania przepisów krajowych odnośnie do dopuszczalnego poziomu ekspozycji są spełnione. Ocena lokalnych narażeń w dłoni wymaga szczegółowej analizy rozkładu współczynnika SAR i dalszych badań. Med. Pr. 2013;64(4):487–501
Background: Use of electro surgery units (ESU) in surgeries is linked with electromagnetic field emission, which is assessed according to the requirements of occupational health and safety legislation. Material and Methods: Surgeons' exposure characteristics was monitored during 11 surgeries (proctectomy, patency of artery, hepatectomy, cystectomy, tonsilectomy, laparoscopy) by real time of monopolar ESU activity recorder. Investigations of root-mean-square value of electric and magnetic field strength was also performed at various modes of ESU operations during cutting (output power, 55-150 W; frequency, 330-445 kHz) and coagulating (40-240 W, 335-770 kHz). Statistical parameters of distribution of ESU operation over any 6-min periods (according to international requirements regarding protection against adverse thermal effects of electromagnetic field) were assessed. Results: Electric field strength, measured 10 cm from the cable supplying an active electrode was 147-675 V/m during cutting and 297-558 V/m during coagulating; magnetic field strength was less than 0.2 A/m in both modes. Monitoring of ESUs showed the following ranges of their operation during surgeries 5-66% of time over starting 3 min of surgery, 3-40% over starting 6 min, and the distribution of their use over any 6-min periods 0-12% (median) / 7-43% (maximum value). Conclusions: The real operation time of ESUs wykoduring surgeries was significantly shorter than that declared by workers. The distance of at least 15 cm between cables, connecting electrodes with generator and workers meets the requirements of the Polish legislation on permissible exposure limits. The assessment of localized exposure of the hand needs a detailed analysis of the SAR ratio distribution and further studies are required. Med Pr 2013;64(4):487–501
Źródło:
Medycyna Pracy; 2013, 64, 4; 487-501
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena narażenia populacji ludzkiej na oddziaływanie cynku, kadmu i ołowiu w środowisku
Environmental exposure evaluation of children population to zinc, cadmium and lead
Autorzy:
Dutkiewicz, T.
Kulka, E.
Sokolowska, D.
Woyciechowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/871384.pdf
Data publikacji:
1978
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
zanieczyszczenia srodowiska
zanieczyszczenia przemyslowe
metale ciezkie
zawartosc metali ciezkich
cynk
kadm
olow
dzieci
mocz
wlosy
woda pitna
oznaczanie zawartosci
dawki dopuszczalne
Źródło:
Roczniki Państwowego Zakładu Higieny; 1978, 29, 3
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena narażenia na hałas na stanowiskach pracy barmanów
Evaluation of on-the-job noise exposure in the case of bartenders
Autorzy:
Dudarewicz, Adam
Zaborowski, Kamil
Wolniakowska, Anna
Pawlaczyk-Łuszczyńska, Małgorzata
Śliwińska-Kowalska, Mariola
Powiązania:
https://bibliotekanauki.pl/articles/2162574.pdf
Data publikacji:
2018-12-18
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
pomiary hałasu
barmani
dyskoteka
klub muzyczny
ekspozycja na hałas
lokale rozrywkowe
noise measurements
bartenders
discotheque
music club
noise exposure level
entertainment venues
Opis:
Wstęp W miejscach związanych z branżą rozrywkową, w których wykonuje się lub odtwarza muzykę, mogą występować dźwięki o wysokich poziomach ciśnienia akustycznego. Taka ekspozycja stanowi zagrożenie zarówno dla osób spędzających wolny czas na koncertach, w dyskotekach czy pubach, jak i dla pracowników tych lokali. Celem przeprowadzonych w 2017 r. badań była ocena narażenia na hałas na stanowisku pracy barmana w różnych miejscach związanych z branżą rozrywkową. Materiał i metody Pomiarami objęto 15 lokali rozrywkowych w Łodzi, spośród których wytypowano 3: klub muzyczny, dyskotekę i pub. Badania ekspozycji na hałas (nadmierne dźwięki) wykonano łącznie na 4 stanowiskach pracy barmanów z zastosowaniem dozymetrii indywidualnej (trzeciej strategii pomiarowej) według PN-EN ISO 9612:2011. Wyniki Przeprowadzono łącznie 64 pomiarów, które wykazały, że równoważne poziomy dźwięku A na stanowisku pracy barmana w zależności od rodzaju lokalu i dnia tygodnia znacznie się różnią, przyjmując wartości 67,6–108,7 dB. Najwyższe poziomy dźwięku występowały podczas weekendu (piątki i soboty). Wyznaczone dzienne poziomy ekspozycji na hałas przekraczały wartości progu działania prewencyjnego (80 dB) w 95% analizowanych przypadków. Przekroczenie wartości najwyższego dopuszczalnego natężenia hałasu (NDN = 85 dB) stwierdzono w 66% przypadków. Wnioski Stwierdzono, że występujące na stanowiskach pracy barmanów poziomy hałasu znacznie przekraczają dopuszczalne wartości poziomów ekspozycji oraz stwarzają ryzyko uszkodzenia słuchu. Med. Pr. 2018;69(6):633–641
Background In places associated with the entertainment industry in which music is performed or played, sounds with high sound pressure levels may occur. Such exposure is a threat to both people spending their free time at concerts, in discos or pubs, as well as employees in these places. The aim of the research conducted in 2017 was to assess on-the-job noise exposure in the case of bartenders at various premises of the entertainment industry. Material and Methods The measurements included 15 entertainment venues in Łódź, out of which 3 were selected: a music club, disco and pub. The exposure measurements were taken together for 4 work stations for bartenders using individual dosimetry in accordance with the PN-EN ISO 9612: 2011 standard. Results A total of 64 measurements were carried out, which showed that the equivalent sound levels A at the bartenders’ workplaces vary considerably depending on the type of premises and the day of the week and the range of 67.6–108.7 dB. The highest sound levels occurred during the weekend (Fridays and Saturdays). The determined daily noise exposure levels exceeded the threshold of preventive action (80 dB) in 95% of the analyzed cases. Exceeding the maximum permissible noise level (NDN = 85 dB) was found in 66% of cases. Conclusions It has been found that on-the-job noise levels in the case of bartenders significantly exceed the acceptable values of exposure levels and pose a risk of hearing damage. Med Pr 2018;69(6):633–641
Źródło:
Medycyna Pracy; 2018, 69, 6; 633-641
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of near field of the GSM base station antennas in urban environment
Autorzy:
Wójcik, D.
Powiązania:
https://bibliotekanauki.pl/articles/309235.pdf
Data publikacji:
2003
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
dozymetria
GSM
RF dosimetries
human exposure
radio base station
ray tracing
Opis:
A simple and efficient method for evaluation of near field of the GSM base station antennas in urban environment is presented in this paper. The method is based on the replacement of panel antenna with a discrete linear array. Moreover, the geometrical optics approach is used to consider the influence of environment. The approximate results are found to be in excellent agreement with the results obtained by using the method of moments (MoM). Presented method can be successfully used for fast evaluation of exposure to electromagnetic fields emitted by the GSM base station antennas in urban environment.
Źródło:
Journal of Telecommunications and Information Technology; 2003, 1; 41-44
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Drgania i hałas na stanowiskach pracy w środkach komunikacji miejskiej - badania dozymetryczne
Evaluation of noise and vibration exposure at workplaces in city transportation using noise and vibration dose meters
Autorzy:
Koton, J.
Majewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/179181.pdf
Data publikacji:
2004
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
hałas
hałas na stanowisku pracy
hałas komunikacyjny
noise
traffic noise
Opis:
Z doniesień literaturowych, zwłaszcza ostatniego dziesięciolecia, wynika, że skojarzone działanie na organizm człowieka dwóch lub więcej szkodliwych i uciążliwych czynników środowiska pracy potęguje niekorzystne skutki działania każdego z nich występującego oddzielnie. Do stanowisk pracy, na których występują łącznie różne czynniki środowiska, należą niewątpliwie stanowiska obsługi wszelkiego rodzaju pojazdów, w tym pojazdów komunikacji miejskiej. W artykule przedstawiono wyniki badań jednoczesnej ekspozycji kierowców na drgania i hałas w autobusach miejskich, tramwajach i w metrze. Uzyskane wyniki porównano z wartościami kryterialnymi ustalonymi dla tych czynników ze względu na ochronę zdrowia w przepisach krajowych i w dyrektywach Unii Europejskiej.
Drivers of city transportation are exposed to noise and vibration, among others, which may affect health, comfort and perception. In order to evaluate occupational exposure and to assess the risk arising from those two agents, measurements were carried out in Warsaw city buses, trams and metro. Daily exposure to noise and vibration was measured simultaneously, throughout the working day, using noise and vibration dose meters. The results of the measurements as well as a comparison of work conditions in specific kinds of city transportation are presented and discussed in this paper. Moreover, the obtained daily exposure to noise and vibration is compared with the requirements of Polish law and the safety requirements of Directive 2002/44/EC (vibration) and Directive 2003/10/EC (noise).
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2004, 7/8; 12-15
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie kryteriów oceny zagrożenia i wartości granicznych ekspozycji na promieniowanie laserowe obowiązujących w Polsce oraz w dyrektywie 2006/25/EU
Comparison of hazard evaluation criteria and exposure limit values of laser’s radiation exposition compulsory in Poland and of EU directive 2006/25/EU
Autorzy:
Wolska, A.
Konieczny, P.
Powiązania:
https://bibliotekanauki.pl/articles/137764.pdf
Data publikacji:
2006
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
promieniowanie laserowe
kryteria oceny zagrożenia zdrowia promieniowaniem laserowym
maksymalne dopuszczalne ekspozycje (MDE)
laser radiation
hazard evaluation criteria of laser radiation
maximum permissible exposures (MPE)
Opis:
W artykule przedstawiono porównanie kryteriów oceny zagrożenia na promieniowanie laserowe zawartych w rozporządzeniu ministra pracy i polityki społecznej z 29 listopada 2002 r. oraz dyrektywie Unii Europejskiej. W celu porównania dokonano obliczeń maksymalnych dopuszczalnych ekspozycji i wartości granicznych ekspozycji na promieniowanie laserowe dla długości fali i czasów trwania impulsów laserowych losowo wybranych spośród wszystkich rodzajów promieniowania laserowego, powodujących uszkodzenia oka i skóry. Na podstawie obliczeń autorzy podjęli próbę rozstrzygnięcia, w którym dokumencie zawarte są bardziej rygorystyczne kryteria.
The article presents comparison of laser’s radiation hazard evaluation criteria contained in regulation of Ministry of Labour and Social Policy and of EU directive. Authors of article calculated exposure limit values of laser’s radiation exposition for random selected wave length and duration of laser pulse from all kind of eyes and skin damages. Based on this calculations they try to say which document contain rigorous criteria.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2006, 3 (49); 5-20
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podstawy oceny zagrożeń elektromagnetycznych podczas pomiarów pola elektromagnetycznego emitowanego przez diatermie chirurgiczne
The principles of evaluating electromagnetic hazards when measuring the electromagnetic field emitted by surgical diathermy devices
Autorzy:
Karpowicz, Jolanta
Gryz, Krzysztof
Zradziński, Patryk
Powiązania:
https://bibliotekanauki.pl/articles/23352061.pdf
Data publikacji:
2022
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
diatermia chirurgiczna
pole elektromagnetyczne
ekspozycja
bezpieczeństwo i higiena pracy
inżynieria środowiska
inżynieria biomedyczna
ocena zagrożeń elektromagnetycznych
surgical diathermy device
electromagnetic field
exposure
occupational safety and health
environmental engineering
biomedical engineering
evaluation of electromagnetic hazards
Opis:
Ochrona przed zagrożeniami elektromagnetycznymi powinna dotyczyć również prac podczas ich oceny, traktowanych jako jeden z przejawów użytkowania źródła pola elektromagnetycznego (pola-EM). Diatermie chirurgiczne zaliczają się do najliczniejszych źródeł pola-EM, które wymaga oceny w środowisku pracy. Przy takich urządzeniach charakterystyka zagrożeń elektromagnetycznych jest podobna podczas wykonywania ich oceny i podczas zabiegów medycznych - jest uzależniona od konfiguracji przestrzennej wyposażenia technicznego w sali operacyjnej (lub zabiegowej) oraz organizacji pracy zespołu pomiarowego/(zabiegowego). Jednakże warunki narażenia zespołu zabiegowego są determinowane w pierwszym rzędzie stanem zdrowia pacjenta, ale również wiedzą i umiejętnościami pracowników organizujących lub przeprowadzających zabiegi. Narażenie na pole-EM jest nieuniknione podczas wykorzystywania diatermii chirurgicznych w zabiegach ratujących zdrowie i życie pacjentów, natomiast podczas pomiarów przy takich urządzeniach można w znacznym stopniu je ograniczyć, opracowując procedury wykonywania pomiarów w optymalnym zakresie i warunkach technicznych – o ile pomiary takie są niezbędne do właściwego rozpoznania i ograniczenia zagrożeń dotyczących pracowników ochrony zdrowia. W artykule przeanalizowano wybrane aspekty tego problemu w kontekście wymagań prawa pracy dotyczących m.in. oceny i ograniczania oddziaływania pola-EM emitowanego przez diatermie chirurgiczne na pracowników, w tym oceny narażenia kończyn. Pomiary pola-EM powinny być zorganizowane w taki sposób, aby miarodajnie ocenić parametry narażenia zespołu zabiegowego (przy wielu urządzeniach osiągającego poziom narażenia niebezpiecznego), ale przy zapewnieniu bezwarunkowej tymczasowości narażenia zespołu pomiarowego, ponieważ prace pomiarowe nie spełniają kryteriów dotyczących warunkowej akceptowalności narażenia niebezpiecznego na pole-EM pracownika (jak określono w rozporządzeniu ministra ds. pracy: DzU 2018, poz. 331). W załączniku artykułu scharakteryzowano ramowe zasady organizowania takich pomiarów i zasady oceny zagrożeń elektromagnetycznych (występujących w różnych warunkach użytkowania diatermii chirurgicznych), obejmującej wykorzystanie danych poza-pomiarowych.
Protection against electromagnetic hazards should also apply to work performed while assessing such hazards, as this is also treated as a use of electromagnetic field (EMF) sources. The most common EMF source for which electromagnetic hazards in the work environment are assessed involves surgical diathermy devices. By such devices, the characteristics of electromagnetic hazards while assessing them has many features in common with the hazards experienced during medical treatments using surgical diathermy devices – they are determined by the configuration of the material objects used in the operating (or treatment) room and the organization of the work of the measuring team / (treatment team). However, the exposure of the treatment team is determined primarily by the patient’s health, as well as by the knowledge and skills of the personnel organizing or performing the treatment. Exposure to the EMF emitted by surgical diathermy devices is inevitable during medical procedures saving the health and life of patients, while exposure during measurements near such devices may be substantially mitigated by developing procedures for performing the measurements in the proper scope and under proper technical conditions – assuming that such measurements are the necessary basis for recognizing and mitigating electromagnetic hazards experienced by the healthcare workers. The article analyses selected aspects of this problem in the context of labour law concerning issues such as the evaluation and mitigation of interactions of EMF emitted by surgical diathermy devices on workers, including evaluation of limb exposure. Measurements of EMF must be organized in such a way as to reliably determine the parameters of the exposure of the treatment team (reaching the level of “dangerous exposure” near many devices), but must also ensure that the exposure of the measuring team is unconditionally “temporary” because the measurement tasks do not fulfill the criteria set with respect to conditional accepting the “dangerous exposure” to EMF for worker (as set out in the labour regulation: J.L 2018, item 331). The principles for organizing such measurements and for assessing electromagnetic hazards (while using surgical diathermy devices), including the use of non-measuringsourced data are described in an appendix to the article.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2022, 4 (114); 79--98
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przegląd miar skutków narażenia na zmienne w czasie pole elektromagnetyczne i właściwości metrologicznych mierników, istotnych podczas oceny narażenia w środowisku pracy
A review of the effects of exposure to a time-varying electromagnetic field and the metrological properties of measurement devices that have a significant influence when evaluating exposure in the work environment
Autorzy:
Bieńkowski, P.
Karpowicz, J.
Kieliszek, J.
Powiązania:
https://bibliotekanauki.pl/articles/137758.pdf
Data publikacji:
2016
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
zagrożenia elektromagnetyczne
narażenie pracowników
ocena ekspozycji
pole elektryczne
pole magnetyczne
electromagnetic hazards
workers’ exposure
exposure evaluation
electric field
magnetic field
Opis:
Eksploatacja wszystkich urządzeń i instalacji zasilanych prądem elektrycznym jest nierozerwalnie związana z zamierzoną lub niezamierzoną emisją energii elektromagnetycznej. W wyniku tej emisji pole elektromagnetyczne powszechnie występuje w środowisku. Bezpośrednim skutkiem oddziaływania pola z obiektami elektroprzewodzącymi (w tym z ciałem człowieka) jest indukowanie pola elektrycznego i prądu elektrycznego w eksponowanych obiektach (pojedynczych obiektach w tzw. wolnej przestrzeni lub w grupach obiektów połączonych galwanicznie). W organizmie człowieka mogą one wywołać elektrostymulację tkanek pobudliwych lub wzrost temperatury, co prowadzi do zaburzeń funkcjonowania organizmu lub utrudnia bezpieczne realizowanie obowiązków zawodowych. Przy identyfikacji, badaniach i ocenie parametrów narażeń na pola elektromagnetyczne są stosowane zarówno techniki pomiarowe, symulacje komputerowe, jak i analiza parametrów technicznych obiektów technicznych emitujących pola elektromagnetyczne. Zwykle największą miarodajność w przypadku oceny zagrożeń zawodowych mają badania in situ, ponieważ umożliwiają ocenę zarówno rzeczywistych parametrów pola elektromagnetycznego w specyficznych warunkach przestrzeni pracy, gdzie eksploatowane mogą być jednocześnie różnorodne urządzenia i instalacje elektryczne oraz rozmieszczone są zróżnicowane obiekty materialne modyfikujące morfologię ekspozycji (m.in. rozkład przestrzenny i zmienność w czasie), jak i ocenę warunków narażenia przy aktualnym stanie technicznym źródeł pola, który zmienia się wskutek zmiennych warunków ich eksploatacji i konserwacji oraz procesów starzeniowych urządzeń. W artykule omówiono: charakterystyki bezpośredniego i pośredniego oddziaływania pola elektromagnetycznego na organizm człowieka, miary skutków narażenia na zmienne w czasie pole elektromagnetyczne (o częstotliwości z pasma od 5 Hz do 300 GHz), parametry charakteryzujące pole elektromagnetyczne w środowisku (stosowane zgodnie z wymaganiami prawa pracy podczas oceny narażenia pracowników), zasady pomiaru pola elektrycznego i magnetycznego oraz właściwości metrologiczne mierników (istotne z punktu widzenia jakości pomiarów wykorzystywanych w dziedzinie bezpieczeństwa i higieny pracy). Ponadto scharakteryzowano czynniki determinujące niepewność pomiarów pola elektromagnetycznego w środowisku pracy, ze szczególnym uzasadnieniem wymagań określających parametry metrologiczne aparatury wykorzystywanej do pomiarów podjętych ze względu na ocenę zgodności warunków narażenia z ustalonymi limitami dotyczącymi natężenia pola elektrycznego i magnetycznego w miejscu pracy.
Any use of electric devices and installations is inextricably linked to the intentional or unintentional emission of electromagnetic energy. Consequently, the electromagnetic field is commonly present in the environment. The direct effects of the electromagnetic influence on electrically conductive objects (including the human body) consists in the electric field and current induction in exposed objects (single objects in the ‘free space, or in groups of objects with galvanic contact). In the human body, they may cause electrostimulation in electro sensitive tissues or an increase in temperature that may lead to malfunctions within the body or difficulties in the safe performance of professional duties. When identifying, investigating and evaluating the parameters of the electromagnetic field, various techniques can be applied: measurements, computer simulations or the analysis of parameters of technical objects emitting an electromagnetic field. The highest quality evaluation of occupational hazards usually comes from in-situ investigations. This is because they allow the evaluation of the real parameters of electromagnetic fields in the particular conditions of the workplace where various electric devices and installations may be used at the same time, and where various physical objects are present that might influence the exposure morphology (e.g. spatial distribution and time variability). They also permit an evaluation of the exposure conditions taking into account the actual technical stage of the field sources, which vary due to changes in the use and maintenance conditions, or due to aging devices. The article presents: the characteristics of direct and indirect interaction between the electromagnetic field and the human body, the measures of exposure to a time-varying electromagnetic field (5 Hz – 300 GHz frequency band), the parameters characterizing the electromagnetic field in the environment (used according to the labour law in evaluations of workers’ exposure), the principles of electric and magnetic field measurements and the metrological properties of measurement devices (significant from the point of view of the quality of measurements used in the area of occupational health and safety). Factors determining the uncertainty of electromagnetic field measurements are also characterized, focusing on the rationale for guidelines on the metrological parameters of devices used in measurements intended to evaluate whether exposure conditions comply with the established limits of electric and magnetic field strength at the workplace.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2016, 4 (90); 41-74
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the TRA ECETOC model for inhalation workplace exposure to different organic solvents for selected process categories
Autorzy:
Kupczewska-Dobecka, Małgorzata
Czerczak, Sławomir
Jakubowski, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2185359.pdf
Data publikacji:
2011-06-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
inhalation exposure assessment
TRA ECETOC estimation
organic solvents occupational exposure
Opis:
Objective: The aim of this work is to describe the operation principle of the TRA ECETOC model developed using the descriptor system, and the utilization of that model for assessment of inhalation exposures to different organic solvents for selected process categories identifying a given application. Method: Measurement results were available for toluene, ethyl acetate and acetone in workplace atmosphere in Poland. The following process categories have been postulated: (1) Paints and lacquers factory: use in closed, continuous process with occasional controlled exposure; (2) Shoe factory: roller or brush application of glues; (3) Refinery: use in closed process, no likelihood of exposure. The next step was to calculate the workplace concentration at chosen process categories by applying the TRA ECETOC model. Results: The selected categories do not precisely describe the studied applications. Very high concentration values of acetone were measured in the shoe factory, mean 443 ppm. The concentration obtained with the aid of the model is underestimated, ranging from 25.47 to 254.7 ppm, for the case with and without activation of the local exhaust ventilation (LEV), respectively. Estimated concentration at a level corresponding to that of the measured concentration would be possible if the process category involving spraying, e.g., PROC 7 was considered. For toluene and ethyl acetate, the measured concentrations are within the predicted ranges determined with the use of the model when we assume the concentration predicted with active ventilation for the beginning, and the concentration predicted with inactive ventilation for the end of the range. Conclusions: Model TRA ECETOC can be easily used to assess inhalation exposure at workplace. It has numerous advantages, its structure is clear, requires few data, is available free of charge. Selection of appropriate process categories related to the uses identified is guarantee of successful exposure assessment.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2011, 24, 2; 208-217
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance evaluation of strip parquet flooring panels after long-term, in-service exposure
Autorzy:
Nemeth, R.
Molnarne Posh, P.
Molnar, S.
Bak, M.
Powiązania:
https://bibliotekanauki.pl/articles/52744.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Drewna
Tematy:
performance
strip parquet flooring
black locust
steaming
panel
long-term exposure
abrasion resistance
indoor service test
dimensional stabilization
Opis:
Due to its extraordinary hardness, decorative appearance and possible small dimensions, black locust wood is assumed to be an excellent material for strip parquetflooring. The favourable colour changes achieved by controlled steam treatment further increased the utilization potential of this material. Flooring was installed on a student dormitory stair landing in heavy use. Due to the flooring’s very high exposure, 5 years was considered a long enough period to compare the different face layer materials during in-service test. Oil was used as a coating to avoid the remarkable protecting effect of hard film-forming varnishes (acrylic, etc.) against abrasion. Besides the flooring turning grey (all face layers no matter what treatment), only some delamination occurred at certain places after five years in service.The laboratory test results for abrasion resistance, dimensional changes and deformation were analysed. Additionally, the Brinell-Mörath hardness after indoor service and the abrasion due to indoor service were analysed. In terms of abrasion resistance, dimensional changes and deformation, no essential differences werefound between the oil-treated and untreated black locust wood on the one hand, and the control oak specimen on the other. Long-term tests showed that, after 5 years in service, the Brinell-Mörath-hardness decreased considerably for all the testedmaterials. The type of section and the presence of wide rays influenced the roughness and the waviness of the surface after indoor service.
Źródło:
Drewno. Prace Naukowe. Doniesienia. Komunikaty; 2014, 57, 193
1644-3985
Pojawia się w:
Drewno. Prace Naukowe. Doniesienia. Komunikaty
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the safety of users of active implantable medical devices (AIMD) in the working environment in terms of exposure to electromagnetic fields – Practical approach to the requirements of European Directive 2013/35/EU
Autorzy:
Zradziński, Patryk
Karpowicz, Jolanta
Gryz, Krzysztof
Leszko, Wiesław
Powiązania:
https://bibliotekanauki.pl/articles/2162037.pdf
Data publikacji:
2018-12-20
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
workers’ safety
cardiac pacemakers
implanted defibrillators
exposure effects
electromagnetic interference
wearable insulin pump
Opis:
Objectives Electromagnetic fields (EMF) may cause malfunctions in electronic devices, in particular in active implantable medical devices (AIMD), along with discomfort or health hazards to users. The use of AIMD by workers is increasing (especially cardiac pacemakers, implantable cardioverter defibrillators and wearable insulin infusion pumps). Electromagnetic fields may be much stronger in the working environment than applied in basic immunity tests of AIMD (based on EN 60601- 1-2:2015 and EN 50527-1:2016). European Directive 2013/35/EU regarding the safety of workers exposed to EMF considered the AIMD users to be “workers at particular risk” who need an individual evaluation of EMF hazards. The study aimed at evaluating the safety of users of AIMD in medical and industrial working environments exposed to EMF Material and Methods Near the common sources of strong EMF applied in medical and industrial use, the “standard safety distances” (SSD) for AIMD users were evaluated (i.e., distances from the EMF source, where exposure drops below limits from Recommendation 1999/519/EC and AIMD safety may be expected). The analysis is based on the results of measurements of magnetic and electric field strengths near 127 typical devices, in their normal use. Results The longest electric field related SSD was identified near dielectric sealers (up to 180 cm), and the longest magnetic field related SSD – near induction heaters (up to 450 cm). Conclusions Electromagnetic fields related AIMD malfunctions need to be considered up to several meters from EMF sources. The “individual safety distance,” that is sufficient to ensure the safety of a particular AIMD user may be significantly different (usually shorter) from the presented SSD, but needs to be considered in the context of detailed safety data from the AIMD manufacturer (if available). The labelling indicating the location of the area of a strong EMF increases safety of AIMD users in the work environment. Int J Occup Med Environ Health 2018;31(6):795–808
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2018, 31, 6; 795-808
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena elektromagnetycznych okoliczności użytkowania nasobnych lokalizatorów
Evaluation of the electromagnetic circumstances of the use of wearable locators
Autorzy:
Zradziński, Patryk
Karpowicz, Jolanta
Gryz, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/23352065.pdf
Data publikacji:
2022
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
pole elektromagnetyczne
skutki bezpośrednie narażenia
skutki pośrednie narażenia
nauki o zdrowiu
inżynieria biomedyczna
inżynieria środowiska
zagrożenia elektromagnetyczne
electromagnetic field
direct effects of exposure
indirect effects of exposure
biomedical engineering
environmental engineering
electromagnetic hazards
Opis:
Lokalizatory, czyli nasobne urządzenia ułatwiające zdalne (elektromagnetyczne) monitorowanie miejsca pobytu lub odnalezienie człowieka, są wykorzystywane w rozwiązaniach poprawiających bezpieczeństwo ludzi w trudnym lub niebezpiecznym terenie. W związku z tym, że lokalizatory mają za zadanie poprawienie bezpieczeństwa ludzi w razie zagrożenia bezpieczeństwa, a nawet życia użytkownika, parametry emitowanego przez nie pola elektromagnetycznego są w znacznym stopniu zdeterminowane spodziewanymi dla takiego zdarzenia okolicznościami technicznymi i parametrami dielektrycznymi środowiska w takim miejscu. Wykonane badania wykazały, że w otoczeniu nasobnych lokalizatorów (takich jak lokalizatory lawinowe, lampy górnicze wyposażone w górniczy nadajnik lokacyjny czy radiotelefony) należy rozpoznać, czy występuje przestrzeń pola elektromagnetycznego o poziomie, przy którym stosuje się systemowe działania związane z ochroną przed zagrożeniami elektromagnetycznymi (tzn. jest tam pole elektromagnetyczne stref ochronnych, o zasięgach zależnych od rodzaju urządzenia i parametrów jego pracy), a przy radiotelefonach pracujących z mocą 4 W lub więcej należy również rozpoznać, czy występuje przestrzeń pola elektromagnetycznego strefy niebezpiecznej (narażenie niebezpieczne). Ze względów funkcjonalnych (konieczność emisji pola elektromagnetycznego w pobliżu ciała pracownika) całkowita eliminacja zagrożeń elektromagnetycznych związanych z użytkowaniem nasobnych lokalizatorów jest niemożliwa. Zaproponowane w niniejszym opracowaniu środki ochronne umożliwiają znaczne ograniczenie omawianych zagrożeń elektromagnetycznych podczas użytkowania lokalizatorów nasobnych.
Locators, i.e. wearable remote (electromagnetic) assisting devices, provide ability to supervise the places to stay or to find a person, they are in solutions that improve the safety of people in harsh or dangerous environment. Due to the fact that the locators are designed to improve the safety of people in the event of a hazardous or even life danger of the user, the parameters of the electromagnetic field emitted by them are determined by the technical circumstances and dielectric parameters of the environment that may occur where the active use of locators is expected. Based on the results of performed studies in the vicinity of wearable locators (such as avalanche locators, mining lamps equipped with a mining locating transmitters, or radiotelephones) it is necessary to recognize whether there is an electromagnetic field space with a level at which systemic measures related to protection against electromagnetic hazards are applied (i.e. with ranges depending on the type of device and its operating parameters), and in the case of radiotelephones operating with a power of 4 W or higher, also whether there is also an electromagnetic field space of the dangerous (conditional) exposure. For functional reasons (the need to emit an electromagnetic field near the worker’s body), complete elimination of electromagnetic hazards related to the use of wearable locators is impossible. The protective measures proposed in this paper make it possible to significantly reduce the discussed electromagnetic hazards during the use of wearable locators.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2022, 4 (114); 65--78
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of a chemical risk assessment method of South Korea for chemicals classified as carcinogenic, mutagenic or reprotoxic (CMR)
Autorzy:
Kim, Min-Uk
Byeon, Sang-Hoon
Powiązania:
https://bibliotekanauki.pl/articles/2162005.pdf
Data publikacji:
2018-07-04
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
exposure
hazard
risk assessment
occupational
work environment
chemical hazard
Opis:
Objectives Chemicals were used in various fields by the development of industry and science and technology. The Chemical Hazard Risk Management (CHARM) was developed to assess the risk of chemicals in South Korea. In this study, we were to evaluate the CHARM model developed for the effective management of workplace chemicals. Material and Methods We used 59 carcinogenic, mutagenic or reprotoxic (CMR) materials, which are both the work environment measurement result and the usage information among the manufacturer data. The CHARM model determines the risk to human health using the exposure level (based on working environment measurements or a combination of the quantity used and chemical physical properties (e.g., fugacity and volatility)), hazard (using occupational exposure limit (OEL) or Risk phrases (R-phrases)/Hazard statements (H-statements) from the Material Safety Data Sheet (MSDS)). Results The risk level was lower when using the results of the work environment measurement than when applying the chemical quantity and physical properties in the exposure level evaluation method. It was evaluated as grade 4 for the CMR material in the hazard class determination. The risk assessment method by R-phrases was evaluated more conservatively than the risk assessment method by OEL. And the risk assessment method by H-statements was evaluated more conservatively than the risk assessment method by R-phrases. Conclusions The CHARM model was gradually conservatively assessed as it proceeded in the next step without quantitative information for individual workplaces. The CHARM is expected to help identify the risk if the hazards and exposure levels of chemicals were identified in individual workplaces. For CMR substances, although CHARM is highly evaluated for hazards, the risk is assessed to be low if exposure levels are assessed low. When evaluating the risk of highly hazardous chemicals such as CMR substances, we believe the model should be adapted to be more conservative and classify these as higher risk. Int J Occup Med Environ Health 2018;31(4):491–501
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2018, 31, 4; 491-501
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of neurotoxicity of repeated dermal application of chlorpyrifos on hippocampus of adult mice
Autorzy:
Mitra, N K
Siong, H.H.
Nadarajah, V.D.
Powiązania:
https://bibliotekanauki.pl/articles/51858.pdf
Data publikacji:
2008
Wydawca:
Instytut Medycyny Wsi
Tematy:
histomorphometry
adult mouse
pesticide
mouse
repeated exposure
mice
dermal toxicity
chlorpyrifos
neurotoxicity
hippocampus
cholinesterase inhibition
Źródło:
Annals of Agricultural and Environmental Medicine; 2008, 15, 2
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the impact of breathing air contamination on safe performance of hyperbaric exposure
Ocena wpływu zanieczyszczeń powietrza oddechowego na bezpieczeństwo wykonywania ekspozycji hiperbarycznych
Autorzy:
Woźniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/222785.pdf
Data publikacji:
2016
Wydawca:
Akademia Marynarki Wojennej. Wydział Dowodzenia i Operacji Morskich
Tematy:
underwater work technology
diving gases
breathing air
technologia prac podwodnych
nurkowe czynniki oddechowe
powietrze oddechowe
Opis:
The evaluation of the impact of contamination in breathing air intended for hyperbaric purposes is essential both for practical and theoretical reasons. The quality of breathing air and the breathing mixes obtained on its basis is of crucial importance with regard to divers’ safety in the course of underwater works. The existing contaminants, as well as substandard quality gases have an adverse impact on divers’ health and life, both in terms of the physiological impact on the body, and fire hazards in hyperbaric complexes. In the process of breathing air production we deal with a few sources of potential contaminants stemming from technical measures. The human body is also responsible for the release of contaminants in hyperbaric conditions. The article presents the above issues and provides insight into existing threats.
Ocena wpływu zanieczyszczeń powietrza oddechowego przeznaczonego do stosowania w celach hiperbarycznych jest bardzo ważna. Jakość powietrza oddechowego oraz otrzymywanych na jego bazie mieszanin oddechowych ma kluczowe znaczenie ze względu na bezpieczeństwo nurków wykonujących prace podwodne. Występujące zanieczyszczenia i dopuszczenie do stosowania czynników o niewłaściwej jakości ma negatywny wpływ na zdrowie i życie nurka zarówno w ujęciu oddziaływania fizjologicznego na organizm, jak również zagrożenia pożarowego w kompleksach hiperbarycznych. W procesie wytwarzania powietrza oddechowego mamy do czynienia z kilkoma źródłami potencjalnych zanieczyszczeń pochodzącymi między innymi ze środków technicznych. Organizm człowieka jest także źródłem emisji zanieczyszczeń w warunkach hiperbarycznych. W artykule przedstawiono te zagadnienia, przybliżając istotę występujących zagrożeń.
Źródło:
Zeszyty Naukowe Akademii Marynarki Wojennej; 2016, R. 57 nr 4 (207), 4 (207); 101-113
0860-889X
Pojawia się w:
Zeszyty Naukowe Akademii Marynarki Wojennej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of circulating microparticles in healthy medical workers occupationally exposed to ionizing radiation: A preliminary study
Autorzy:
Al-Massarani, Ghassan
Najjar, Fadi
Aljapawe, Abdulmunim
Ikhtiar, Adnan
Powiązania:
https://bibliotekanauki.pl/articles/2162036.pdf
Data publikacji:
2018-12-20
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
biomarkers
flow cytometry
occupational exposure
microparticles
ionizing radiation
cellular damage
Opis:
Objectives Ionizing radiation was known to cause disruption of cytoskeleton. However, the disorganization of the cytoskeleton leads to form microparticles (MP) that carry membrane and cytoplasmic constituents from their parent cells they are released from. Therefore, authors investigated the effect of the occupational exposure to low doses of ionizing radiation on MP levels. Material and Methods The current study was conducted on 38 healthy medical workers occupationally exposed to low doses of ionizing radiation and 29 controls matched by gender, age, and smoking habits. The MP levels measured by flow cytometry were classified as positive or negative phosphatidylserine (PS⁺ or PS⁻), and phenotyped according to their cellular origin. Results Total MP (PS–/PS+) levels, regardless of phenotype, were significantly higher in workers occupationally exposed to ionizing radiation than in healthy individuals (p = 0.0004). Negative phosphatidylserine microparticles were predominant in medical exposed workers and, to a lesser extent, in controls (68% and 57%, respectively). With regard to phenotypic characterization of cellular origin, MP derived from platelets (CD41a+), endothelial (CD146+), leucocytes (CD45+) and erythrocytes (CD235a+) MP were significantly enhanced in exposed workers compared with controls (p < 0.0001). However, no significant difference was found in the proportion of the other blood elements in the peripheral circulation between the 2 groups. Serum levels of C-reactive protein were normal for all individuals. In addition, no association was observed between MP levels and the studied confounding factors. Conclusions The results suggest that elevated circulating MP levels represent an indicator of cellular damage caused by medical exposure to low doses of ionizing radiation. By consequence, the quantification of MP seems to be a useful biomarker for assessing the negative effects of occupational exposure to ionizing radiation. Int J Occup Med Environ Health 2018;31(6):783–793
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2018, 31, 6; 783-793
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stanu wiedzy dotyczącej zachorowalności na ostre zapalenie wątroby typu B i C wśród personelu medycznego.
Evaluation of medical staff knowledge about the incidence of hepatitis B and C.
Autorzy:
Salasa, Małgorzata
Goździalska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/528077.pdf
Data publikacji:
2015
Wydawca:
Krakowska Akademia im. Andrzeja Frycza Modrzewskiego
Tematy:
infection post-exposure
puncture
nurses
doctors
zakażenia poekspozycyjne
zakłucia
pielęgniarki
lekarze
Opis:
Introduction: Nosocomial infections largely concern health professionals. The increased range of medical services and surgical procedures leads to an increased incidence of hepatitis B (HBV) and C (HCV) infections among this professional group. The main cause of nosocomial infections among people working in the healthcare sector is occupational diseases resulting from exposure to biological agents in the line of official duties. According to WHO, every year the world’s 3 million health workers are exposed to percutaneous contact with blood-borne pathogens. The aim of the study was to assess medical staff knowledge concerning the incidence of acute hepatitis B and C. Results and conclusion: Analysis of medical staff knowledge on the incidence of hepatitis B and C shows that medical staff do know how they should behave when they come into contact with infectious material in the healthcare institutions.
Wprowadzenie: Zakażenia szpitalne w dużej mierze dotyczą samych pracowników służby zdrowia. Zwiększony zakres usług medycznych, w tym dużo większa liczba zabiegów operacyjnych, ma wpływ na wzrost zakażeń wirusami zapalenia wątroby typu B (HBV) i C (HCV) w tej grupie zawodowej. Głównymi czynnikami wystąpienia zakażeń szpitalnych wśród osób zatrudnionych w sektorze opieki zdrowotnej, są choroby będące wynikiem narażenia na czynniki biologiczne w trakcie wykonywania czynności służbowych. Według WHO, co roku na świecie 3 miliony pracowników medycznych jest narażonych na przezskórny kontakt z krwiopochodnymi patogenami. Celem badań była ocena wiedzy dotycząca zachorowalności na ostre zapalenie wątroby typu B i C wśród personelu medycznego. Wyniki i wnioski: Analiza poziomu wiedzy personelu medycznego na temat zachorowalności na WZW typu B i C wskazuje na właściwe zachowania w przypadku kontaktu z materiałem zakaźnym w placówkach służby zdrowia.
Źródło:
Państwo i Społeczeństwo; 2015, 3; 23-36
1643-8299
2451-0858
Pojawia się w:
Państwo i Społeczeństwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Self-Assessment of Hearing Status and Risk of Noise-Induced Hearing Loss in Workers in a Rolling Stock Plant
Autorzy:
Pawlaczyk-Łuszczyńska, M.
Dudarewicz, A.
Zamojska, M.
Śliwinska-Kowalska, M.
Powiązania:
https://bibliotekanauki.pl/articles/90180.pdf
Data publikacji:
2012
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
self-assessment of hearing ability
occupational exposure to noise
risk factors for noise-induced hearing loss (NIHL)
evaluation of NIHL risk
Opis:
Noise measurements and questionnaire inquiries were carried out for 124 workers of a rolling stock plant to develop a hearing conservation program. On the basis of that data, the risk of noise-induced hearing loss (NIHL) was evaluated. Additionally, the workers’ hearing ability was assessed with the (modified) Amsterdam inventory for auditory disability and handicap, (m)AIADH. The workers had been exposed to noise at A-weighted daily noise exposure levels of 74–110 dB for 1-40 years. Almost one third of the workers complained of hearing impairment and the (m)AIADH results showed some hearing difficulties in over half of them. The estimated risk of hearing loss over 25 dB in the frequency range of 3-6 kHz was 41–50% when the standard method of predicting NIHL specified in Standard No. ISO 1999:1990 was used. This risk increased to 50-67% when noise impulsiveness, coexposure to organic solvents, elevated blood pressure and smoking were included in calculations.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2012, 18, 2; 279-296
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of selected properties and surface quality of cured pre-impregnated carbon-fiber fabrics after exposure to sulphuric acid
Autorzy:
Kojnoková, Tatiana
Nový, František
Markovičová, Lenka
Harea, Evgheni
Harea, Evghenii
Powiązania:
https://bibliotekanauki.pl/articles/26081735.pdf
Data publikacji:
2023
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
tkaniny węglowe
żywica epoksydowa
zmiana wagi
jakość powierzchni
carbon fabrics
epoxy resin
micro-hardness
weight change
surface quality
Opis:
This paper deals with changes in selected properties of composite material and surface degradation after exposure to an acidic environment. A carbon fiber-reinforced composite (CFRP) produced from prepregs was tested. The weight change, micro-hardness, and surface degradation of the CFRP composite made of cured pre-impregnated laminates were evaluated in this study. Material consisting of a DT121R epoxy resin matrix with high reactivity and high viscosity, with two reinforcing carbon fabrics layers, is characterized by a low value of tensile strength. Evaluation of changes in the material properties was performed before and after exposure to specific environmental conditions, which are achieved by using a chemical solution of 15% H2SO4 at various temperatures. Subsequently, the effect of 15% H2SO4 at various temperatures on the material properties was monitored. The specimens were immersed in the solution for up to 3 and 6 weeks at the temperatures of 23°C, 40°C, and 60°C. It was found out, that the degradation of the composite material is conditioned by the aging of the epoxy resin (matrix). Carbon fibers (reinforcement) are relatively stable. The weight change, micro-hardness, and surface quality depend on the time of exposure to acidic solution and temperature. The micro-hardness tests show a significant influence on exposure time. The biggest changes in weight change and surface quality of the CFRP composite were observed after exposure at the temperature of 60°C.
Źródło:
Production Engineering Archives; 2023, 29, 1; 1--6
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis and evaluation of effectiveness of a controlled release preparation 2,4-D: a reduction of risk of pollution and exposure of workers
Autorzy:
Kowalski, W. J.
Romanowska, I.
Smol, M.
Silowiecki, A.
Głazek, M.
Powiązania:
https://bibliotekanauki.pl/articles/204646.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acids
2,4-dichlorophenoxy acetic acid (2,4-D)
controlled release
ring opening polymerization of B-butyrolactone
SEC
ESI-MS characterization of oligomers
NMR spectroscopy
assessment of herbicide effectiveness
Opis:
A novel herbicidal controlled release formulation composed of (2,4-dichlorophenoxy) acetic acid (2,4-D) chemically bonded to biodegradable (R,S)-3-hydroxybutyric acid oligomers was investigated. The synthesis of (R,S)-3-hydroxy butyric acid oligomers was carried out via the ring opening polymerization of â-butyrolactone initiated by 2,4-dichlorophenoxy acetic potassium salt in the presence of complexing agents. The formed oligomers were characterized by size exclusion chromatography, proton magnetic resonance and electrospray mass spectrometry in order to fi nd out their molar mass distribution and molecular structures. An assessment of biological effectiveness of the obtained herbicidal formulation was carried out in the greenhouse vs. Sinapis alba var. Nakielska. A promotion of the controlled release formulation with decreased water solubility and with low vapor pressure of the active ingredient, instead of traditional formulations of 2,4-dichlorophenoxy acetic acid may help to ensure a greater safety for workers and reduce the risk of dissemination of the active ingredient in the soil profile.
Źródło:
Archives of Environmental Protection; 2012, 38, 3; 119-129
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmierzchowa czułość kontrastowa jako dodatkowy parametr oceny zmęczenia wzroku spowodowanego ekspozycją na olśnienie przykre
Mesopic contrast sensitivity as an additional parameter for evaluation of visual fatigue caused by discomfort glare exposure
Autorzy:
Wolska, A.
Sawicki, D.
Powiązania:
https://bibliotekanauki.pl/articles/159576.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
olśnienie przykre
zmierzchowa czułość kontrastowa
wrażliwość na olśnienie
ocena olśnienia przykrego
Opis:
W artykule przedstawiono metodę oraz wyniki badań zmian zmierzchowej czułości kontrastowej po ekspozycji na olśnienie przykre osób w różnym wieku. Zmierzchowa czułość kontrastowa bez olśnienia i z olśnieniem są standardowymi parametrami ocenianymi wśród kandydatów na kierowców zawodowych. Na podstawie tych parametrów ocenia się czy widzenie zmierzchowe kierowców jest wystarczająco dobre oraz czy ich wrażliwość na olśnienie przeszkadzające jest wystarczająco mała do bezpiecznego prowadzenia pojazdów. Dotychczas nie brane były one pod uwagę, ani przy ocenie poziomu olśnienia przykrego, ani przy sprawdzeniu czy ekspozycja na olśnienie przykre ma wpływ na te parametry. Przeprowadzono zestaw badań z udziałem grupy 65 osób przy dwóch poziomach olśnienia przykrego. Badania te wykazały, że zmierzchowa czułość kontrastowa bez oraz z olśnieniem mogą być traktowane jako dodatkowe i obiektywne parametry wskazujące na zmęczenie wzroku powodowane olśnieniem przykrym, zwłaszcza dla osób w wieku powyżej pięćdziesiątego roku życia.
The article presents method and results of mesopic contrast sensitivity measurements after exposure to discomfort glare subjects of different age. Mesopic contrast sensitivity in conditions of glare and no glare are standard parameters which are measured during psychomotoric examinations of professional drivers. These parameters have not been taken into account yet neither for glare evaluation nor for checking if the exposure to glare influence these parameters. The series of experiments were carried out under two different discomfort glare conditions on 65 subjects. The results of study showed that mesopic contrast sensitivity in conditions of glare and no glare could be additional objective parameters of visual fatigue caused by discomfort glare, especially for subjects of age above 50 years old.
Źródło:
Prace Instytutu Elektrotechniki; 2014, 266; 157-166
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wiedzy pielęgniarek bloku operacyjnego w zakresie ochrony radiologicznej : wyniki badań własnych w wybranej placówce
Evaluation of operating theatre nurses knowledge on radiological protection : original research results
Autorzy:
Antkowiak, K.
Kunecka, D.
Powiązania:
https://bibliotekanauki.pl/articles/180056.pdf
Data publikacji:
2018
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
wiedza
ochrona radiologiczna
narażenie na promieniowanie
promieniowanie jonizujące
knowledge
radiation protection
exposure to irradiation
ionizing radiation
Opis:
Praca pielęgniarek niesie ze sobą ryzyko narażenia zawodowego na czynniki szkodliwe. Każde miejsce pracy może mieć odrębna specyfikę, która wpływa na rodzaj ekspozycji zawodowej związanej wykonywanym zawodem. Blok operacyjny to miejsce pracy wysoko specjalistyczne, na którym jednym z zagrożeń jest napromieniowanie. Ponieważ w coraz większej liczbie zabiegów operacyjnych, wykorzystywane są kopie rentgenowskie, za cel pracy przyjęto ocenę poziomu wiedzy personelu pielęgniarskiego wybranego bloku operacyjnego na temat promieniowania jonizującego oraz zasad ochrony radiologicznej. Za metodę badawczą posłużył sondaż diagnostyczny, w którym wykorzystano autorski kwestionariusz ankiety. W badaniu udział wzięło 45 pielęgniarek zatrudnionych w bloku operacyjnym. Uzyskane wyniki wskazują, iż personel pielęgniarski ma wiedzę na temat ochrony radiologicznej na poziomie Średnim. Zaobserwowano, iż wraz z długością stażu pracy na bloku operacyjnym wzrasta me tylko poziom wiedzy w zakresie ochrony radiologicznej, ale co ważniejsze-przekłada się ona w praktyce na przestrzeganie ogólnych wytycznych ochrony radiologicznej, a także stosowanie indywidualnych środków ochrony pracownika.
A nursing job is closely associated with a risk of exposure to a number of harmful factors. Every workplace has its own distinctive features which may result in a specific kind of occupational exposure. An operating theatre is a highly technical place, where irradiation constitutes one of the risks. Fluoroscopy is often used in surgery, because of technological development, which brings not only benefits, but also an extraordinary risk of medical staff being exposed to radiation. Therefore, this study aimed to evaluate operating theatre nurses' knowledge on ionizing radiation and the principles of protection against radiation. A diagnostic survey was used as a method of analysis, in which an original questionnaire was applied as an expertise tool. The study involved 45 nurses employed in an operating theatre. The results indicate that the knowledge of the nurses on radiological protection is at a medium level. Moreover, it turned out that there is a trend indicating that with the length of service in the operating theatre not only does the level of knowledge in the field of radiological protection increase, but more importantly, it has impact on the nurses' experience at complying with common principles of protection against radiation and at using personal protective equipment.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2018, 11; 10-14
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena rentgenowskich aparatów stomatologicznych pod kątem narażenia pacjentów na promieniowanie jonizujące
Evaluation of dental X-ray apparatus in terms of patient exposure to ionizing radiation
Autorzy:
Olszewski, Jerzy
Wrzesień, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2164069.pdf
Data publikacji:
2017-06-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
pacjent
promieniowanie rentgenowskie
radiologia stomatologiczna
wejściowa dawka powierzchniowa (ESD)
ankieta
detektory termoluminescencyjne
patient
X-ray
dental radiology
entrance surface dose (ESD)
questionnaire
thermoluminescent dosimeter
Opis:
Wstęp Stosowanie w procedurach stomatologicznych promieniowania rentgenowskiego (rtg.) powoduje narażenie pacjenta na promieniowanie jonizujące. Wielkość tego narażenia zależy przede wszystkim od parametrów stosowanych przy prześwietleniu zęba. Celem badań było określenie wielkości dawek, na jakie narażeni są pacjenci, oraz ocena stanu technicznego aparatów rtg. Materiał i metody Badaniami ankietowymi objęto 1700 gabinetów stomatologicznych. Ankiety odesłało 740 jednostek. Pomiary bezpośrednie wykonano w 100 gabinetach. Pomiary wykonano za pomocą detektorów termoluminescencyjnych i klisz rtg. Wyniki W przeprowadzonych badaniach stwierdzono, że najczęściej stosowany czas ekspozycji wynosi 0,22±0,16 s. Średnia dawka wejściowa dla parametrów najczęściej stosowanych przez stomatologów to 1,7±1,4 mGy. Średnia wydajność lampy rtg. oszacowana na podstawie wykonanych ekspozycji wynosi 46,5±23,7 μGy/mAs. Wnioski Jak wynika z przeprowadzonych badań, znakomita większość aparatów rtg. punktowych spełnia wymagania określone w przepisach. Med. Pr. 2017;68(4):491–496
Background The use of X-ray in dental procedures causes exposure of the patient to ionizing radiation. This exposure depends primarily on the parameters used in tooth examination. The aim of the study was to determine the patients exposure and to assess the technical condition of X-ray tubes. Material and Methods Seventeen hundred dental offices were covered by the questionnaire survey and 740 questionnaires were sent back. Direct measurements were performed in 100 units by using the thermoluminescent detectors and X-ray films. Results The results showed that the most commonly used exposure time is 0.22±0.16 s. The average entrance dose for the parameters used most commonly by dentists is 1.7±1.4 mGy. The average efficiency of X-ray tube estimated on the basis of exposures is 46.5±23.7 μGy/mAs. Conclusions The study results indicate that the vast majority of X-ray tubes meet the requirements specified in the binding regulations. Med Pr 2017;67(4):491–496
Źródło:
Medycyna Pracy; 2017, 68, 4; 491-496
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena hałasu generowanego przez skanery rezonansu magnetycznego i jego wpływu na narząd słuchu - badania pilotażowe
The evaluation of the noise emitted by magnetic resonance scanners and its influence on the sense of hearing - a pilot study
Autorzy:
Morzyński, L.
Kozłowski, E.
Młyński, R.
Karpowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/261527.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
skaner rezonansu magnetycznego
hałas
narażenie zawodowe
occupational exposure
magnetic resonance scanner
acoustic noise
Opis:
W pracy przedstawiono wyniki badań hałasu wytwarzanego przez skanery rezonansu magnetycznego o indukcji magnetycznej 1,5 T. Wykazano dużą rozpiętość wartości ciśnienia akustycznego hałasu w zależności od rodzaju badania. Równoważny poziom dźwięku A (LAeq,Tp) zawierał się w przedziale 69,8-96,3 dB, maksymalny poziom dźwięku A (LAmax) w przedziale 81,4-106,8 dB, a szczytowy poziom dźwięku C w przedziale 98-116,7 dB. Przeprowadzona ocena zagrożenia hałasem pracowników dowodzi, że długotrwałe przebywanie w pobliżu pracującego skanera może powodować przekroczenie wartości dopuszczalnego narażenia i prowadzić do uszkodzenia słuchu.
In this paper, the results of examination of acoustic noise, generated by 1,5 T magnetic resonance scanners, are reported. The measurement results showed the wide range of sound pressure level values, depending on the type of examination. The A-weighted equivalent sound level (LAeq,Tp) was in the range of 69,8-96,3 dB, the maximum A-weighted sound level (LAmax) maintained within the range of 81,4-106,8 dB, and the peak C-weighted sound level was in the range of 98-116,7 dB. The assessment of the occupational hazard, resulting from the exposure to the noise revealed that the prolonged contact with an active scanner may result in overcome of the maximum allowable level of exposure to acoustic noise and thus, it may cause the hearing damage.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2011, 17, 4; 292-296
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe kryteria oceny zagrożeń zdrowia wynikających z niezamierzonej ekspozycji na promieniowanie laserowe
New criteria of eye and skin hazards evaluation arising from accidental exposure to laser radiation
Autorzy:
Wolska, A.
Głogowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/209365.pdf
Data publikacji:
2009
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
optoelektronika
MDE
zagrożenie termiczne
zagrożenie fotochemiczne
kryteria oceny zagrożenia promieniowaniem laserowym
optoelectronics
MPE
thermal damage
photochemical damage
criteria occupational risk assessment
Opis:
W artykule przedstawiono podstawowe zagrożenia dla oka i skóry wynikające z ekspozycji na promieniowanie laserowe oraz wybrane dane statystyczne dotyczące wypadków związanych z obsługą urządzeń laserowych. Omówiono nowe kryteria oceny zagrożenia promieniowaniem laserowym dla zdrowia, zawarte w Dyrektywie 2006/25/WE, której wymagania muszą być wdrożone do prawa polskiego do 27 kwietnia 2010 r. Scharakteryzowano zasady wyznaczania wartości Maksymalnych Dopuszczalnych Ekspozycji (MDE) w zależności od: długości fali promieniowania, trybu pracy urządzenia (ciągły, impulsowy), czasu ekspozycji oraz wytłumaczono znaczenia wprowadzonych współczynników korekcyjnych oraz punktów czasowych przy wyznaczaniu MDE. W sposób graficzny przedstawiono przebiegi zmienności MDE w funkcji czasu ekspozycji, długości fali oraz kąta widzenia źródła promieniowania dla poszczególnych podzakresów promieniowania optycznego (UV, VIS, IR). Przedstawiono również podobieństwa i różnice między kryteriami obowiązującymi w chwili obecnej w Polsce zawartymi w Rozporządzeniu MPiPS w sprawie najwyższych dopuszczalnych stężeń i natężeń czynników szkodliwych dla zdrowia w środowisku pracy oraz kryteriami zawartymi w Dyrektywie 2006/25/WE.
Laser devices have found recently wide range of applications like: industry, medicine, science, telecommunication, environment and military. Probability of exposition to laser radiation that can be hazardous is very small, especially when personnel using laser devices wear protective clothes, especially protective eyewear. Hazards arising from exposition to laser radiation are related separately to eye and skin. Hazards may be caused by direct beam, as well as reflected and scattered beam (depending on laser class). Laser radiation in the whole optical range (180 nm - 1 mm) causes thermal effect in exposed tissue (presently lasers devices generate radiation in the range of 180 nm - 40 µm). As thermal effects we can mention: tissue temperature increase, erythema, coagulation, vaporization, carbonization, photoablation and electromechanics phenomenon. Occurrence of those effects depends on laser radiation power density, wave - length, type of exposed tissue (eye and skin) and exposition time. The highest level of radiation that does not cause any damage to exposed tissue is called Maximal Permissible Exposure (MPE). In Poland, values of MPE to laser radiation are included in Regulation of Ministry of Labour and Social Policy on maximal permissible concentrations and intensities of hazardous factors in Labour environment. In Europe, values of MPE to laser radiation are included in annex no. II to Directive 2006/25/EU. The article presents eye and skin hazards related to the exposition to laser radiation and statistical data on accidents while operating laser devices. New criteria of eye and skin hazards evaluation arising from laser radiation, included in Directive 2006/25/EU have been presented. Those criteria have to be implemented into Polish law until 27 April 2010. Rules for defining values of the Maximal Permissible Exposure (MPE) in dependence of: laser radiation wavelength, device work regime (CW or pulsed), exposure time have been presented. Values of correction factors and time points necessary for MPE defining have been explained. Article includes charts showing variations of MPE values as a function of exposure time, radiation wavelength and angular subtense of a source for different ranges of optical radiation (UV, VIS, IR). The article presents comparison of laser's radiation hazard evaluation criteria contained in regulation of Ministry of Labour and Social Policy (on maximal permissible concentrations and intensities of hazardous factors in Labour environment) and EU Directive.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2009, 58, 4; 351-367
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania stali konstrukcyjnej po pożarze w kontekście oceny możliwości jej dalszego użytkowania w elementach nośnych ustrojów budowlanych
Testing of construction steel after a fire to assess the possibility of its continued use in the load-bearing elements of built structures
Autorzy:
Maślak, M.
Powiązania:
https://bibliotekanauki.pl/articles/163444.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja stalowa
pożar
oddziaływanie termiczne
właściwości mechaniczne
zmiany mikrostrukturalne
ocena przydatności
steel construction
fire exposure
thermal impact
mechanical properties
microstructural changes
usability evaluation
Opis:
W pracy wskazano na potrzebę uzupełnienia typowego zakresu badań eksperckich odnoszonych do właściwości stali konstrukcyjnej po pożarze, co najmniej o analizę jej mikrostruktury, a także o testy twardości i udarności. Są one o tyle istotne, że pozwalają ocenić czy na skutek trwałych zmian strukturalnych po przejściu sekwencji epizodów gwałtownego nagrzewania i stygnięcia, w szczególności ewentualnej rekrystalizacji materiału, wytrącania grafitu, powstawania cementytu kulkowego lub koalescencji faz międzymetalicznych, nie nastąpił znaczący wzrost podatności na kruche pękanie. Cecha ta może dyskwalifikować stal czyniąc ją nieprzydatną do dalszego użytkowania, pomimo braku zaobserwowania wyraźnych deformacji wykonanego z niej elementu konstrukcyjnego.
This article points out the need for the normal range of expert testing regarding the properties of construction steel following a fire to be expanded to include at least analysis of its microstructure, and also tests of hardness and impact resistance. These are important in that they enable assessment of whether, as a result of persistent structural changes following a sequence of episodes of rapid heating and cooling, in particular the possible recrystallization of the material, precipitation of graphite, formation of globular cementite or coalescence of intermetallic phases, there has been a significant increase in susceptibility to brittle cracking. This characteristic may disqualify the steel, making it unsuitable for continued use, in spite of the absence of clearly observable deformation of the structural element made from the steel.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 6, 6; 48-51
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary evaluation of ER- and AhR-mediated gene expression patterns in rainbow trout (Oncorhynchus mykiss) liver after short-term exposure to zearalenone in binary mixtures
Autorzy:
Woźny, M.
Brzuzan, P.
Wolińska, L.
Góra, M.
Łuczyński, M. K.
Powiązania:
https://bibliotekanauki.pl/articles/363144.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
receptor AhR
benzo(a)piren
ścieżka sygnałowa
17beta-estradiol
receptor estrogenowy
zearalenone
aryl hydrocarbon receptor
benzo(a)pyrene
crosstalk
estrogen receptor
Opis:
While estrogenic properties of mycotoxin zearalenone (ZEA) has been an extensively studied issue, little is known about molecular background of its biological responses that cannot be simply explained by the estrogenic potential. The present study describes effects of ZEA (10mg*kg-1 body weight) in binary mixtures either with benzo[a]pyrene (B[a]P), or with 17β-estradiol (E2) on ER- and AhR-dependent gene expression in juvenile rainbow trout liver, evaluated using Real-Time qPCR. The study revealed dual nature of ZEA, as the treatment with this compound alone increased mRNA levels of both ER- and AhR-mediated gene expression. However, our results did not show any synergistic or additive effect of ZEA in binary mixures with E2 or B[a]P on studied gene expression levels. Whether the intriguing potential of ZEA to elicit distinct signals was a result of binding affinity to AhR or/and ER and AhR mutual receptor interactions, should be investigated in further experiments.
Źródło:
Environmental Biotechnology; 2010, 6, 1; 16-23
1734-4964
Pojawia się w:
Environmental Biotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zawartość lotnych związków organicznych w powietrzu na terenie jednostki ratowniczo-gaśniczej. Ocena potencjalnych źródeł ich pochodzenia oraz negatywnego wpływu na zdrowie strażaka
Volatile organic compounds in ambient air of firefighting and rescue unit, evaluation of the vocs emission sources and potential negative health effects for firefighters
Autorzy:
Łukawski, Aleksander Szymon
Powiązania:
https://bibliotekanauki.pl/articles/136689.pdf
Data publikacji:
2019
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
lotne związki organiczne
ekspozycja
inhalacja
źródła emisji LZO
oddziaływanie na zdrowie
jakość powietrza w jednostkach ratowniczo-gaśniczych
volatile organic compounds
exposure
inhalation
emission sources of VOCs
health effects
ambient air quality in firefighting and rescue units
Opis:
W artykule przebadano ilość lotnych związków organicznych (LZO) występujących w dwóch wybranych punktach na terenie wybranej jednostki ratowniczo-gaśniczej (JRG). Analizowano powietrze z garażu oraz kabiny samochodu gaśniczego za pomocą tubek dyfuzyjnych zawierających sorbent Tenax-TA®. Przy wykorzystaniu techniki chromatografii gazowej sprzężonej ze spektrometrią mas, oznaczono związki pochłonięte z powietrza. Oznaczono wysokie stężenia toluenu, m/p-ksylenów i benzenu. Wykorzystując otrzymane dane pomiarowe oraz dane o profilach i stężeniach LZO zaczerpnięte z literatury, przeanalizowano potencjalne źródła LZO oznaczonych w powietrzu wybranej JRG. Wykazano, że źródłami LZO w powietrzu były m.in. spaliny silników mechanicznych i pożary. W oparciu o dostępne dane opisano również potencjalny negatywny wpływ lotnych związków organicznych na zdrowie strażaków przebywających w jednostce ratowniczo-gaśniczej. Na podstawie porównania z publikacjami oceniono, że powietrze z terenu JRG, oddziałując chronicznie, może stanowić zagrożenie dla zdrowia strażaków.
Concentrations of volatile organic compounds in ambient air of Firefighting and Rescue Unit were identified in this article. The sampling was done in the garage area and the cabin of the first response fire engine. Air sampling was performed with the diffusion tubes containing the Tenax-TA® sorbent. Analysis was done using gas the chromatography-mass spectrometry method. In result, there were found the significant concentrations of toluene, m/p-xylenes and benzene. The potential VOCs emission sources were identified due to comparison with literature. The comparison proved that the main sources of the VOCs emission were engine exhausts and fires. The potential negative health effects of the VOCs exposure for firefighters were also described. The concentrations of the VOCs found in ambient air were recognized as harmful to firefighters’ health.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2019, 2, 70; 21-44
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-56 z 56

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies