Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "electron-beam radiation" wg kryterium: Wszystkie pola


Wyświetlanie 1-31 z 31
Tytuł:
Application of Electron Beam Radiation to Modify Crosslink Structure in Rubber Vulcanizates and Its Tribological Consequences
Autorzy:
Stępkowska, A.
Bieliński, D.
Przybytniak, G.
Powiązania:
https://bibliotekanauki.pl/articles/1503891.pdf
Data publikacji:
2011-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.05.Lg
61.80.Fe
81.40.Pq
Opis:
The aim of this work was the modification of crosslink density and structure of rubber vulcanizates in order to control surface energy, mechanical strength under static as well as dynamic conditions and in consequence, tribological properties of the materials. Sulphur vulcanizates of styrene-butadiene rubber, filled with carbon black, were subjected to electron beam radiation in the range from 150 to 200 kGy. Changes in crosslink density and structure were determined applying the method of selective swelling of rubber in "hard" and "soft" solvents. The modification influences the ability of material of energy dissipation and its surface wettability. The changes are discussed from the friction and abrasion of rubber point of view.
Źródło:
Acta Physica Polonica A; 2011, 120, 1; 53-55
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ promieniowania elektronowego na bioresorbowalne terpolimery zawierające paklitaksel
The influence of electron beam radiation on bioresorbable terpolymers containing paclitaxel
Autorzy:
Musiał-Kulik, M.
Kasperczyk, J.
Jelonek, K.
Gębarowska, K.
Janeczek, H.
Dobrzyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/284820.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
bioresorbowalne terpolimery
paklitaksel
promieniowanie elektronowe
sterylizacja
polimery z pamięcią kształtu
bioresorbable terpolymers
paclitaxel
electron beam radiation
sterilization
shape memory polymers
Opis:
Sterylizacja jest bardzo ważnym czynnikiem uzależniającym przydatność materiałów do zastosowań medycznych. Obiecującą metodą sterylizacji wydaje się być promieniowanie wiązką elektronową. Celem badania była analiza wpływu promieniowania elektro-nowego (EB) na terpolimery zawierające paklitaksel. Dwa typy materiałów użyto do przygotowania matryc zawierających 5 i 10% leku, jak również matryc bez leku: poli(L-laktyd-ko-glikolid-ko-ε-kaprolakton) (44:32:24) – P(LA:GA:Cap) oraz poli(L-laktyd-ko-gli-kolid-ko-węglan trimetylenu) (62:27:11) – P(LA:GA:TMC). Wszystkie otrzymane matryce badano przed i po procesie elektronowego napromieniania dawką 25kGy za pomocą spektroskopii NMR, DSC i GPC. Nie wykazano różnic w składzie komonomerów, temperaturze zeszklenia, liczbowo średniej masie cząsteczkowej jak również w rozrzucie mas cząsteczkowych (dyspersyjność) pomiędzy matrycami otrzymanymi z tego samego typu terpolimeru przed procesem sterylizacji. Promieniowanie elektronowe spowodowało spadek liczbowo średniej masy cząsteczkowej oraz temperatury zeszklenia. Zmiany w składzie komonomerów zauważono tylko w przypadku matryc z P(LA:GA:Cap), co może sugerować mniejszą odporność jednostek kaproilowych na sterylizację.
Sterilization is a very important factor determining usefulness of materials for medical application. The promising method of sterilization seems to be electron beam radiation. The aim of this study was to analyze the influence of the EB radiation on terpolymers containing paclitaxel. Two types of materials were used to prepare three kinds of matrices – with 5% and 10% of paclitaxel as well as drug free matrices. The selected terpolymers were: poly(L-lactide-co-glycolide-co-ε-caprolactone) (44:32:24) – P(LA:GA:Cap) and poly(L-lactide-co-glycolide-co-trimethylene carbon-ate) (62:27:11) – P(LA:GA:TMC). All of the obtained matrices were investigated before and after electron beam (EB) irradiation with the dose of 25 kGy with the use of 1H NMR spectroscopy, DSC and GPC. There were no differences in comonomer molar ratio, glass transition temperature, the number average molecular weight and dispersity index between non-irradiated matrices prepared from the same terpolymer type, regardless paclitaxel content. EB radiation caused decrease of the number average molecular weight as well as the glass-transition temperature. The changes of comonomer units’ ratio were noticed only in the case of P(LA:GA:Cap) matrices that may suggest lower susceptibility to sterilization of caproyl units.
Źródło:
Engineering of Biomaterials; 2010, 13, 94; 24-27
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical and thermal properties of commercial multilayer flexible plastic packaging materials irradiated with electron beam
Autorzy:
Oliveira, V. M.
Nogueira, B. R.
Ortiz, A. V.
Moura, E. A. B.
Powiązania:
https://bibliotekanauki.pl/articles/146772.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron-beam radiation
multilayer packaging materials
mechanical properties
thermal properties
Opis:
The effects of electron-beam irradiation on mechanical and thermal properties were studied for two commercial multilayer structures of flexible food packaging. Both the laminated poly(ethylene terephthalate) (PET)/ low-density polyethylene (LDPE) and the coextruded LDPE/polyamide(PA)/LDPE structures were irradiated up to 120 kGy using a 1.5 MeV electron beam accelerator, at room temperature in the presence of air. Mechanical properties showed significant changes (p < 0.05), specially in sealability that was severely affected. Changes in mechanical properties were discussed in relation to the eight day and the six month period after irradiation. In addition, the DSC analysis six months after treatment showed that the fusion enthalpy of the PET/LDPE structure components increase for the LDPE from 10 kGy and decrease for the PET up to 120 kGy (p < 0.05). On the other hand, the LDPE/PA6/ LDPE presented increase in the LDPE and PA up to 120 kGy, except for LDPE at 10 and 15 kGy and PA at 5 kGy doses (p < 0.05). The effects of irradiation were less severe for the LDPE/PA6/LDPE than for the PET/LDPE. The electron-beam irradiation did not show advantageous results that could be of interest for commercial applications for the film industry, but brings important information about the packaging behavior for food producers who may decide to use irradiation as a form of cold pasteurization of their packed products.
Źródło:
Nukleonika; 2008, 53, suppl. 2; 141-144
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie metodą EPR wolnych rodników w polimerze UHMWPE stosowanym w biomedycznych węzłach tarcia
The EPR method investigation of free radicals in polymer UHMWPE applied in the biomedical knots of the friction
Autorzy:
Czaja, P.
Cybo, J.
Maszybrocka, J.
Barylski, A.
Michniowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/189804.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polietylen UHMWPE
napromieniowanie strumieniem elektronów
wolne rodniki
EPR
polyethylene UHMWPE
electron beam radiation
free radicals
EPR method
Opis:
W artykule zostały przedstawione wyniki badań EPR wolnych rodników dla dwu gatunków polietylenu o ultrawysokiej masie cząsteczkowej: GUR 1020 i GUR 1050, poddanych napromieniowaniu wiązką elektronów o energii 10 MeV i o krotności napromieniowania i = 1, 2, 3, 4, 6, dawką o mocy 26 kGy. Wraz ze wzrostem dawki promieniowania zwiększa się ilość wolnych rodników w badanym materiale. Zarówno w przypadku polietylenu GUR 1020, jak i GUR 1050 nie obserwuje się stanu nasycenia przy maksymalnej dawce promieniowania równej 156 kGy. Świadczyć to może o zbliżonej odporności radiacyjnej badanych materiałów.
In this paper, the results of EPR measuring of free radicals for two types of polyethylene of ultra high molecular weight: GUR 1020 and GUR 1050 are presented. Samples were irradiated by electron beam energy of 10 MeV and dose 26 kGy a number of times (i = 1, 2, 3, 4, or 6). With the increase of radiation, the amount of free radicals increases as well. In both cases of polyethylene GUR 1020 and GUR 1050, the effect of saturation at the maximum dose of radiation equal 156 kGy was not observed. This proves that both types of material show similar radiation resistance.
Źródło:
Tribologia; 2011, 5; 39-47
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterylizacja radiacyjna bioresorbowalnych kopolimerów zawierających lek cytostatyczny
Radiation sterilization of bioresorbable copolymers with the cytostatic drug
Autorzy:
Musiał-Kulik, M.
Gębarowska, K.
Janeczek, H.
Pastusiak, M.
Kasperczyk, J.
Dobrzyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/284740.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
poli(L-laktydo-ko-węglan trimetylen)
paklitaksel
promieniowanie gamma
napromienianie wiązką elektronów
sterylizacja
poly(L-lactide-co-trimethylene carbonate)
paclitaxel
gamma irradiation
electron beam radiation
sterilization
Opis:
Istnieje wiele metod sterylizacji wyrobów medycznych. Jednak najbardziej użytecznymi metodami sterylizacji syntetycznych, bioresorbowalnych polimerów wydają się być promieniowanie gamma oraz napromienianie wiązką elektronów (EB). Celem tej pracy było określenie wpływu wspomnianych metod na trzy rodzaje matryc - zawierających 3%, 5% paklitakselu oraz matryc bez leku. Badane matryce otrzymano z dwóch rodzajówpoli(L-laktydo-ko-węglanu trimetylenu) zsyntezowanych w 150°C (P1) oraz 120°C (P2). Nie zaobserwowano znaczących różnic w składzie komonomerów matryc sterylnych i niesterylnych, zawierających paklitaksel, jak i matryc bez leku. Spadek temperatury zeszklenia (Tg) wynikał ze zmniejszenia się średniej długości bloków laktydylowych oraz węglanowych, a także utraty Mn po procesie sterylizacji. Zauważalne były niewielkie różnice we właściwościach fizykochemicznych matryc napromienianych promieniowaniem gamma oraz wiązką elektronów. Otrzymane wyniki pokazują, iż lepszą metodą sterylizacji poli(L-laktydo-ko-węglanu trimetylenu) wydaje się być napromienianie wiązką elektronów.
There are many methods of sterilization approved for medical devices. However, the most usable methods of synthetic, bioresorbable polymers sterilization seem to be gamma radiation and electron beam irradiation (EB). The aim of this work was to determine the impact of mentioned methods on three types of matrices - containing 3%, 5% of paclitaxel and also drug free matrices. The studied matrices were obtained from two poly(L-lactide-co-trimethylene-carbonates) synthesized at 150°C (P1) and 120°C (P2). No significant differences of comonomers' composition were observed in sterile and non-sterile matrices containing paclitaxel as well as drug free matrices. The decrease of the glass transition temperature (Tg) resulted from decrease of the lactidyl and carbonate units' content and the Mn loss after radiation. Small dissimilarities of physicochemical features between gamma and EB radiated matrices were noticeable. Thus, the obtained data showed that better method of sterilization of poly(L-lactide-co-trimethylene carbonates) seems to be electron beam radiation.
Źródło:
Engineering of Biomaterials; 2013, 16, 118; 18-22
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterylizacja radiacyjna bioresorbowalnych kopolimerów zawierających lek cytostatyczny
Radiation sterilization of bioresorbable copolymers with the cytostatic drug
Autorzy:
Musiał-Kulik, M.
Gębarowska, K.
Janeczek, H.
Pastusiak, M.
Kasperczyk, J.
Dobrzyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/286205.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
poli(L-laktydo-ko-węglan trimetylen)
paklitaksel
promieniowanie gamma
napromieniowanie wiązką elektronów
sterylizacja
poly(L-lactide-co-trimethylene carbonate)
paclitaxel
gamma irradiation
electron beam radiation
sterilization
Opis:
Istnieje wiele metod sterylizacji wyrobów medycznych. Jednak najbardziej użytecznymi metodami sterylizacji syntetycznych, bioresorbowalnych polimerów wydają się być promieniowanie gamma oraz napromienianie wiązką elektronów (EB). Celem tej pracy było określenie wpływu wspomnianych metod na trzy rodzaje matryc - zawierających 3%, 5% paklitakselu oraz matryc bez leku. Badane matryce otrzymano z dwóch rodzajów poli(L-laktydo-ko-węglanu trimetylenu) zsyntezowanych w 150°C (P1) oraz 120°C (P2). Nie zaobserwowano znaczących różnic w składzie komonomerów matryc sterylnych i niesterylnych, zawierających paklitaksel, jak i matryc bez leku. Spadek temperatury zeszklenia, Tg, wynikał ze zmniejszenia się średniej długości bloków laktydylowych oraz węglanowych, a także utraty Mn po procesie sterylizacji. Zauważalne były niewielkie różnice we właściwościach fizykochemicznych matryc napromienianych promieniowaniem gamma oraz wiązką elektronów. Otrzymane wyniki pokazują, iż lepszą metodą sterylizacji poli(L-laktydo-ko-węglanu trimetylenu) wydaje się być napromienianie wiązką elektronów.
There are many methods of sterilization approved for medical devices. However, the most usable methods of synthetic, bioresorbable polymers sterilization seem to be gamma radiation and electron beam irradiation (EB). The aim of this work was to determine the impact of mentioned methods on three types of matrices - containing 3%, 5% of paclitaxel and also drug free matrices. The studied matrices were obtained from two poly(L-lactide-co-trimethylene-carbonates) synthesized at 150°C (P1) and 120°C (P2). No significant differences of comonomers' composition were observed in sterile and non-sterile matrices containing paclitaxel as well as drug free matrices. The decrease of the glass transition temperature, Tg, resulted from decrease of the lactidyl and carbonate units' content and the Mn loss after radiation. Small dissimilarities of physicochemical features between gamma and EB radiated matrices were noticeable. Thus, the obtained data showed that better method of sterilization poly(L-lactide-co-trimethylene carbonates) seems to be electron beam radiation.
Źródło:
Engineering of Biomaterials; 2012, 15, no. 116-117 spec. iss.; 74-78
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Atomic force microscopy investigation of electron beam (EB) irradiated composites based on biodegradable polymers and coconut fiber*
Autorzy:
Kodama, Y.
Oishi, A.
Nagasawa, N.
Nakayama, K.
Tamada, M.
Machado, L. D. B.
Powiązania:
https://bibliotekanauki.pl/articles/147470.pdf
Data publikacji:
2013
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
atomic force microscopy (AFM)
coconut fiber
electron beam (EB) radiation
force modulation microscopy (FMM)
poly(ε-caprolactone) (PCL)
poly(L-lactic acid) (PLLA)
scanning electron microscopy (SEM)
Opis:
In this study, the addition of natural fibers to biodegradable PCL, PLLA blend and the effect of ionizing radiation on the surface of composites were investigated by force modulation microscopy (FMM), atomic force microscopy (AFM) and scanning electron microscopy (SEM). Hot pressed sheets were prepared using pellets of twin extruded PCL:PLLA 20:80 (w:w) blend containing 5% or 10% weight concentration of coconut fiber. In this study coconut fibers non treated chemically and acetylated ones were used. Irradiation was performed using an electron beam (EB) accelerator and an absorbed dose of 100 kGy. FMM images acquisition was obtained using a silicon cantilever, intermittent contact mode (tapping mode). Also, AFM images were obtained using tapping mode but J scanner. By FMM, it was possible to observe regions with different elasticity indicating fiber presence under the surface of the composite. Furthermore, it appears that the spherical structures size decreased on composites. This probably was induced by ionizing radiation.
Źródło:
Nukleonika; 2013, 58, 4; 459-468
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bone powder as EPR dosimetry system for electron and gamma radiation
Autorzy:
Ziaie, F.
Hajiloo, N.
Fathollahi, H.
Mehtieva, S. I.
Powiązania:
https://bibliotekanauki.pl/articles/148156.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
bone powder dosimeter
EPR response
dose rate
electron beam
gamma ray
Opis:
In this work bovine bone powder samples were irradiated at three different dose rates of 100, 260 and 630 kGy/min for the absorbed dose range of 3 to 110 kGy, using 10 MeV electron beam radiation. The samples were subjected to EPR measurement at room temperature in air. The variation of EPR signal intensities were constructed and evaluated base on quantitative data related to the absorbed doses. Moreover, they were compared with the obtained results from the samples irradiated by a 60Co gamma-ray source with a dose rate of 2.65 kGy/h. The time and temperature effects on the EPR response of this dosimeter were also studied. The results indicated that the bone sample was a suitable dosimeter especially for electron beam at high doses.
Źródło:
Nukleonika; 2009, 54, 4; 267-270
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Decomposition of diclofenac in sewage from municipal wastewater treatment plant using ionizing radiation
Autorzy:
Bojanowska-Czajka, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2055688.pdf
Data publikacji:
2021
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
diclofenac
degradation efficiency
electron beam
gamma rays
sewage sludge
Opis:
The decomposition of diclofenac (DCF) in sewage sludge from municipal wastewater treatment plant was investigated. It was found that adsorption of DCF on sludge is about 40%. Compared to previous studies, where the degradation yield in aqueous solution was 100%, in those experiments at the dose up to 5 kGy, only 50% of initial DCF concentration of 50 mg L−1 was decomposed in sediment and in solution over the sediment. The experiments were carried out using both gamma radiation and electron beam. It has been observed that DCF in the aqueous phase, above the sediment, was decomposed with the same efficiency using both gamma radiation and electron beam. Whereas for DCF in the sediment, a higher degradation efficiency was found when gamma radiation was applied. This is most likely due to the limited penetration depth of the electron beam into the sludge layer. It was shown that the applied peroxide addition (in a stoichiometric amount needed for complete mineralization of 50 mg L−1 DCF) did not cause increase in yield of DCF decomposition.
Źródło:
Nukleonika; 2021, 66, 4; 201--206
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Specific heat of selected graphites used in calorimetry of electron beam and its influence on the accuracy of measurement of large dose
Autorzy:
Panta, P.
Głuszewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/147858.pdf
Data publikacji:
2005
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radiation processing
radiation sterilization
electron beam (EB)
high dose calorimetry
calibration
electron energy
Opis:
Calorimetry is applicable to both absolute calibration of routine dosimeters and absolute measurements of electron beam (EB) intensity (for industrial radiation processing). Advantages of graphite as the absorbing calorimetric material are a good heat capacity and negligible heat defect of this material. Knowledge of the specific heat capacities of the calorimetric core materials is fundamental in making absolute dose measurements. Two kinds of high-purity graphite used in calorimeters were analysed, i.e. Union Carbide grade AGOT and nuclear grade graphite [10]. There are some differences of specific heat of these graphites, up to 2% , which influence dosimetric response of calorimeters made of them.
Źródło:
Nukleonika; 2005, 50,suppl.2; 55-57
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Od radiacyjnej sterylizacji do modyfikacji polimerów
From radiation sterilization to polymer modification
Autorzy:
Głuszewski, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/24201006.pdf
Data publikacji:
2023
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radioliza
sterylizacja radiacyjna
chemia radiacyjna polimerów
wiązka elektronów
promieniowanie gamma
promieniowanie hamowania
radiolysis
radiation sterilization
radiation chemistry of polymers
electron beam
gamma radiation
braking radiation
Opis:
Zapotrzebowanie na tzw. zimne metody sterylizacji spowodowało, że opłacalne stało się projektowanie i budowa źródeł promieniowania jonizującego dużej mocy. Technologie radiacyjne pozwalają wyjaławiać wyroby w: dowolnej temperaturze, krótkim czasie oraz całej objętości (opakowaniu indywidulanym i zbiorczym). Działanie wiązki elektronów (EB), promieniowania gamma (γ) oraz hamowania nie pozostawia szkodliwych zanieczyszczeń. W artykule opisano, jak poszukiwania odpornych radiacyjnie tworzyw sztucznych dla zastosowań medycznych dały początek chemii radiacyjnej polimerów. Kolejnym przełomem było odkrycie zjawiska radiacyjnego sieciowania polietylenu, które współcześnie wykorzystuje się np. w: produkcji opon samochodowych, kabli elektrycznych i materiałów z tzw. pamięcią kształtu. Technologie radiacyjne rozwinęły się w kierunku bardzo zaawansowanych rozwiązań w zakresie naturalnych i syntetycznych polimerów. Przykładowo wymieniono badania nad: sieciowaniem materiałów komórkowych w produkcji wałków dylatacyjnych, modyfikację kompozytów polimerowych polipropylen(PP)/włókna konopne(HF) oraz PP/ścier drzewny.
The demand for the so-called cold sterilization methods made it profitable to design and build high-power ionizing radiation sources. Radiation technologies allow sterilization of products at: any temperature, short time and the entire volume (individual and collective packaging). The action of electron beam (EB), gamma radiation (γ) and bremsstrahlung no harmful contaminants. The article describes how the search for radiation-resistant plastics for medical applications gave rise to the radiation chemistry of polymers. Another breakthrough was the discovery of the phenomenon of radiation cross-linking of polyethylene, which is currently used, for example, in the production of car tires, electric cables and materials from the so-called shape memory. Radiation technologies have developed into very advanced solutions in the field of natural and synthetic polymers. Examples include research on: cross-linking of cellular materials in the production of expansion rolls, modification of polymer composites polypropylene (PP) / hemp fibers (HF) and PP / wood pulp.
Źródło:
Postępy Techniki Jądrowej; 2023, 3; 21--27
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of electron radiation on sugar content in inverted liquid sugar
Autorzy:
Podadera, P.
Sabato, S. F.
Powiązania:
https://bibliotekanauki.pl/articles/148037.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beam
ionizing radiation
inverted liquid sugar
physicochemical properties
Opis:
Inverted liquid sugar is a mixture of sucrose, glucose and fructose, which shows its relevant characteristic on high sweetness power. Ionizing radiation has been applied to different kind of food and ingredients for different reasons, such as pathogens reduction, disinfestations, quarantine purposes, ripening delay among others. Radiation from an electron beam can be utilized as a technique to treat this ingredient because it can process a great volume of material per unit of time. The main goal of this paper was to verify the effect of radiation on the properties of inverted liquid sugar. This ingredient was irradiated in an electron accelerator (Radiation Dynamics) at a dose ranging from 5 to 50 kGy. Sucrose content measurements were reduced by 23% at 30 kGy when compared to control and the reduced sugar content increased around 11%. Density and moisture values were not affected by radiation. The total soluble solids (Brix degrees) rose in function of the absorbed dose.
Źródło:
Nukleonika; 2009, 54, 2; 85-87
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiation processing of polymers and semiconductors at the Institute of Nuclear Chemistry and Technology
Autorzy:
Zimek, Z.
Przybytniak, G.
Kałuska, I.
Powiązania:
https://bibliotekanauki.pl/articles/146107.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beam accelerators
radiation processing
Opis:
R&D studies in the field of radiation technology in Poland are mostly concentrated at the Institute of Nuclear Chemistry and Technology (INCT). The results of the INCT works on polymer and semiconductor modification have been implemented in various branches of national economy, particularly in industry and medicine. Radiation technology for polymer modification was implemented in the middle of the 1970-ties. Among others, the processes of irradiation and heat shrinkable products expansion have been developed. The transfer of this technology to Polish industry was performed in the middle of the 1980-ties. The present study aims at the formulation of new PE composites better suited to new generation of heat shrinkable products, for example, a new generation of hot-melt adhesives has been developed to meet specific requirements of customers. Modified polypropylene was used for the production of medical devices sterilized by radiation, especially disposable syringes, to overcome the low radiation resistance of the basic material. Modified polypropylene (PP-M) has been formulated at the INCT to provide material suitable for medical application and radiation sterilization process. Modification of semiconductor devices by EB was applied on an industrial scale since 1978 when the INCT and the LAMINA semiconductor factory successfully adopted that technology to improve specific semiconductor devices. This activity is continued on commercial basis where the INCT facilities served to contract irradiation of certain semiconductor devices according to the manufacturing program of the Polish factory and customers from abroad.
Źródło:
Nukleonika; 2006, 51,suppl.1; 129-132
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiation curing: coatings and composites
Autorzy:
Berejka, A. J.
Montoney, D.
Cleland, M. R.
Loiseau, L.
Powiązania:
https://bibliotekanauki.pl/articles/148453.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radiation curing
fiber composites
coatings
electron beam
X-ray
matrices
Opis:
The initial experiments conducted in the late 1960's at Radiation Dynamics, Inc. (now IBA Industrial, Inc.) showed that by removing the pigment from a radiation curable coating formulation, the same binder system could be used as a matrix system for electron beam (EB) cured fiber reinforced composites. Recently, the binder systems used for EB curable coatings have also been successfully used (without pigments) as the matrices for EB and X-ray cured fiber composites. Insights gained from the development of coatings were translated into desirable properties for matrix materials. For example, understanding the surface wetting characteristics of a coating facilitated the development of a matrix that would wet fibers; the development of coatings that would adhere to rigid substrates as metal while being bent, as for coil coatings, and which would exhibit impact resistance when cured on a metal also imparted impact resistance to cured composite materials. Thermal analyses conducted on the coating binder cured at low energies were consistent with analyses performed on thick cross-sections as used for matrices. The configuration of the final product then dictated the modality of curing, be it low-energy EB for coatings or higher energy EB or X-ray curing for composites. In industrial radiation chemistry, one deals with monomers and oligomers (similar to 102 and similar to 103 to 104 Daltons molecular weight, respectively). Thus, one can approach the development of coating binders or matrix systems as one would approach the synthesis of organic polymers. The desired final material is a fully cured and cross-linked polymer. In contrast, concepts involved in “formulating” are often derived from dealing with high molecular weight polymers (similar to 105 + Daltons) in which intense mechanical mixing is used to bring different ingredients together. When synthesizing a radiation curable coating or matrix system, greater attention is given to microphase compatibility as reflected in the microhomogeneity of the entire material.
Źródło:
Nukleonika; 2010, 55, 1; 97-106
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
‘Zero energy’ electron beam technology for sludge hygienization
Autorzy:
Chmielewski, Andrzej G.
Sudlitz, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/147406.pdf
Data publikacji:
2019
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
biogas
sewage sludge
ionizing radiation
hygienization
Opis:
Large quantity of sewage sludge originating from wastewater treatment plants is becoming a growing problem from environmental and human health points of view. One of the ways to use sewage sludge is agricultural purpose due to its nutrients and organic matter content, but the condition is that it should be deprived of pathogenic bacteria and parasite egg contamination. Application of ionizing radiation to hygienize sewage sludge can make it appropriate for agricultural use. The process does not require addition of chemicals to sludge; it is environmentally friendly and effective in removal of biological threats. In the past, successful attempts of sewage sludge treatment using ionizing radiation were made. Pilot plants and commercial ones proved that pathogens can be easily removed from sewage sludge by ionizing radiation. The concept of ‘zero energy’ biogas plant is based on the construction of a complex system consisting of biogas plant and electron accelerator in the biofertilizer manufacturing line. Digestate originating from the methane fermentation of sewage sludge is irradiated to remove all pathogens using electron beam from an accelerator powered by electric energy obtained from burning biogas in a cogenerator. The product is a high-quality, biologically safe fertilizer.
Źródło:
Nukleonika; 2019, 64, 2; 55-63
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Long-term radiation-induced effects on solid state chitosan
Autorzy:
Gryczka, Urszula
Powiązania:
https://bibliotekanauki.pl/articles/2131484.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Polskie Towarzystwo Chitynowe
Tematy:
chitosan
electron beam irradiation
ionising irradiation
post-irradiation effect
Opis:
Treatment of chitosan with ionising radiation is one of the methods by which it is modified for various applications. However, in the case of chitosan irradiated in the solid state, the radicals formed during irradiation can be stabilised in its crystalline phase and subsequently cause post-irradiation changes. It has been observed that further degradation of the polymer occurs during storage of the irradiated polymer, resulting in an increase in oxidation products and a decrease in deacetylation degree. This effect results from the transformation of radicals leading to the formation of stable nitroxyl radicals, a process observed years after irradiation.
Źródło:
Progress on Chemistry and Application of Chitin and its Derivatives; 2021, 26; 80-88
1896-5644
Pojawia się w:
Progress on Chemistry and Application of Chitin and its Derivatives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetic modelling of NO heterogeneous radiation-catalytic oxidation on the TiO2 surface in humid air under the electron beam irradiation
Autorzy:
Nichipor, H.
Sun, Y.
Chmielewski, A. G.
Powiązania:
https://bibliotekanauki.pl/articles/148642.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beam
catalyst
reaction kinetics
NOx removal
irradiation
modelling
Opis:
Theoretical study of NOx removal from humid air by a hybrid system (catalyst combined with electron beam) was carried out. The purpose of this work is to study the possibility to decrease energy consumption for NOx removal. The kinetics of radiation catalytic oxidation of NO on the catalyst TiO2 surface under electron beam irradiation was elaborated. Program Scilab 5.3.0 was used for numerical simulations. Influential parameters such as inlet NO concentration, dose, gas flow rate, water concentration and catalyst contents that can affect NOx removal efficiency were studied. The results of calculation show that the removal effiiency of NOx might be increased by 8–16% with the presence of a catalyst in the gas irradiated field.
Źródło:
Nukleonika; 2017, 62, 3; 235-240
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electron beam technology for biogas and biofertilizer generation at municipal resource recovery facilities
Autorzy:
Chmielewski, Andrzej G.
Sudlitz, Marcin
Han, Bumsoo
Pillai, Suresh D.
Powiązania:
https://bibliotekanauki.pl/articles/2055685.pdf
Data publikacji:
2021
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
biogas
biofertilizer
cogeneration
electron beam
ionizing radiation
municipal wastewater plant sludge
phosphorus
resource recovery facility
sludge hygenization
Opis:
In the era of circular economies, municipal wastewater treatment plants (WWTPs) are viewed as resource recovery facilities. At the very minimum, the targeted resources are water, biogas, and phosphorus. However, municipal wastewater streams (sludge and effluent) need to be adequately treated to eliminate the potential for the transmission of microbial pathogens including protozoa, bacteria, and viruses. This paper presents the results from a study demonstrating the use of electron beam technology for sludge hygenization and enhanced methane (biogas) production using municipal wastewater samples. Cogeneration of heat for fertilizer drying and granulation and electricity for powering the electron beam system are also demonstrated.
Źródło:
Nukleonika; 2021, 66, 4; 213--219
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiacyjna modyfikacja tworzyw polimerowych stosowanych w medycynie
Radiation modification of polymer plastics used in medicine
Autorzy:
Głuszewski, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/2146771.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
radioliza
polimery
wiązka elektronów
promieniowanie gamma
promieniowanie hamowania
sterylizacja radiacyjna
wyroby medyczne
implanty
radiolysis
polymers
electron beam
gamma radiation
X-radiation
radiation sterilization
medical devices
implants
Opis:
Za pomocą promieniowania jonizującego można korzystnie modyfikować właściwości materiałów polimerowych. Planując wykorzystanie naturalnych i syntetycznych polimerów w wyrobach medycznych i implantach chirurgicznych, należy pamiętać, że powinny być one wolne od wegetatywnych, przetrwalnikowych oraz zarodnikowych form mikroorganizmów. Techniki radiacyjne są unikatowymi metodami sterylizacji pozwalającymi w krótkim czasie wyjaławiać materiał w całej objętości, w dowolnej temperaturze (również warunkach kriogenicznych), w opakowaniu jednostkowym i zbiorczym. Co istotne, w odróżnieniu od tradycyjnych metod chemicznych (gazowych) działanie promieniowania jonizującego nie pozostawia szkodliwych zanieczyszczeń. Temat jest stale aktualny w związku z postępem w dziedzinie konstrukcji źródeł promieniowania jonizującego oraz pojawianiem się nowych tworzyw sztucznych. W szczególności zwrócono uwagę na radiolizę znajdujących coraz więcej zastosowań tworzyw biodegradowalnych. Jako przykład omówiono materiały komórkowe (pianki) na bazie polilaktydu (PLA) i polikaprolaktonu (PCL). W tym przypadku wielkością dawki pochłoniętej promieniowania można kontrolować (skracać) czas ich biowchłanialności. Wspomniano również o badaniach nad nowymi kompozytami typu polimer/metal wykorzystywanymi w ochronie radiologicznej, radiacyjnej polimeryzacji, którą można prowadzić bez inicjatorów i/lub katalizatorów oraz o modyfikacji powierzchni polimerów.
Ionizing radiation can advantageously modify the properties of polymeric materials. When planning the use of natural and synthetic polymers in medical devices and surgical implants, it should be remembered that they should be free of vegetative, spore and spore forms of microorganisms. Radiation techniques are unique sterilization methods that quickly sterilize the material in its entire volume at any temperature (including cryogenic conditions), in unit and collective packaging. Importantly, unlike traditional chemical (gas) methods, ionizing radiation does not leave harmful contaminants. The topic is constantly relevant in connection with the progress in the field of construction of ionizing radiation sources and the emergence of new plastics. In particular, attention has been paid to the radiolysis of more and more applications of biodegradable plastics. As an example, cell materials (foams) based on polylactide (PLA) and polycaprolactone (PCL) are discussed. In this case, the amount of radiation absorbed dose can be controlled (shortened) their biosorbability time. The following were also mentioned – the research on new polymer/metal composites used in radiation protection, radiation polymerization that can be carried out without initiators and/or catalysts, and modification of polymer surfaces by tacking.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 3; 163--167
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combination of methods of thermal and radiation treatment of sediments associated with PCBs : the Delor type
Autorzy:
Fülöp, Marko
Šagátová, Andrea
Benkovský, Ivan
Prokes, Karel
Foltinova, Lubica
Powiązania:
https://bibliotekanauki.pl/articles/2055684.pdf
Data publikacji:
2021
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beam
heat treatment
polychlorinated biphenyls
radiation degradation
Opis:
An efficient method of burning polychlorinated biphenyls (PCBs) is often used to remove the environmental burden of PCBs. However, combustion produces toxic dioxins and furans (PCDD/F), so residents are increasingly rejecting this method. The heat treatment (HT) method does not burn PCBs but evaporates it from sediments. Even in this process, PCDD/Fs are formed to a lesser extent, which are destroyed by radiation processing (RP) following the HT. At the same time, the RP method degrades PCB congeners down to biphenyls, which decompose easily in the environment. A block assembly of a complex synergistic combination of equipment for methods of thermal (HT) and radiation (RP) destruction of PCBs in sediments is proposed. The efficacy of this complex was preliminarily determined at a level of 70-fold reduction in PCB concentration in sediments. To achieve a higher reduction factor in the concentration of PCBs, possible procedures for optimizing the settings of individual devices of this complex are presented.
Źródło:
Nukleonika; 2021, 66, 4; 207--211
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electron beam decomposition of pollutant model compounds in aqueous systems
Autorzy:
Ting, T. -M.
Dahlan, K. Z. M.
Powiązania:
https://bibliotekanauki.pl/articles/147660.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
absorbed dose
concentration of solute
ionizing radiation
organic decomposition
Opis:
In this study, factors that limit the utilization of electron beam irradiation for decomposition of pollutants were investigated. Potassium hydrogen phthalate (KHP) was used as the model pollutant compound. The accumulated chemical oxygen demand (COD) removal below 2.4 kGy (applied for concentration at 85, 170, 255, 425 and 850 mg/l) was less than 10 per cent, whereas the accumulated COD removal at 215 kGy (applied for concentration at 85, 170, 255, 425 and 850 mg/l) was 198 per cent. At a lower concentration of KHP, 85 mg/l, the accumulated COD removal (for dose ranging from 0.5 to 215 kGy) was 236per cent. As the concentration of KHP increases to 850 mg/l, almost no COD removal was recorded (for dose ranging from 0.5 to 215 kGy). The results show that the removal efficiency and effectiveness of pollutants were influenced by the solute concentration and irradiation dose. When the concentration of KHP increases to a certain level, water radical species were not sufficient to form KHP radicals and, therefore, reduce the decomposition of KHP molecules. Removal of phthalate as measured by COD was restricted at a very high concentration, 850 mg/l. This indicates that the by-products have scavenged the radicals rapidly. This also suggests that, the limitation of radiolytic products of water to decompose KHP at higher concentration. A large quantity of KHP molecules would also stabilize the KHP radicals and resulting in lower removal of KHP. Similar removal trend was also observed for the actual industrial wastewater.
Źródło:
Nukleonika; 2011, 56, 4; 349-355
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chemia radiacyjna jako źródło unikatowych technologii syntezy i modyfikacji polimerów
Radiation chemistry as a source of unique technologies of synthesis and modification of polymers
Autorzy:
Głuszewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/214135.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radioliza
polimery
promieniowanie jonizujące
wiązka elektronów
promieniowanie gamma
radiolysis
polymers
ionizing radiation
electron beam
gamma radiation
Opis:
Nawiązując do obchodzonej w tym roku 150. rocznicy urodzin Marii Skłodowskiej-Curie przypominam publikację, która dała początek radiacyjnej sterylizacji wyrobów medycznych jednorazowego użytku. W pracy tej uczona zwróciła również uwagę na heterogoniczny charakter oddziaływania promieniowania jonizującego na materię. Dopiero współcześnie posługując się modelem gniazd jonizacji wyjaśniono otrzymane eksperymentalnie krzywe radiacyjnej inaktywacji. Pierwotne procesy zachodzące w gniazdach jonizacji są nadal obiektem badań. W szczególności dyskutowane są mechanizmy zjawiska ochronnego obserwowanego w chemii radiacyjnej związków organicznych. Tłumaczone jest ono zarówno przeniesieniem wolnego rodnika jak i energii lub ładunku. Prowadzone przy nas badania skłaniają do stwierdzenia, że najbardziej prawdopodobny jest mechanizm wędrówki stanu wzbudzonego (energii). W ten sposób można wytłumaczyć raczej mało prawdopodobne spotkanie się dwóch makrorodników w procesie radiacyjnego sieciowania. Zwracam uwagę na rolę gniazd wielojonizacyjnych w radiolizie tworzyw polimerowych. Również w tym przypadku eksperymentalnie potwierdzono ochronne działanie związków aromatycznych. Benzen i jego pochodne oraz wyższe węglowodory aromatyczne mogą częściowo rozpraszać energię deponowaną w gniazdach o dużym LET (linear energy transfer). Warto podkreślić, że znakomita większość naturalnych i syntetycznych antyoksydantów to związki aromatyczne. Unikatowe cechy obróbki radiacyjnej wynikają ze stosunkowo prostego, wydajnego i łatwego w kontroli sposobu tworzenia wolnych rodników. Z tego powodu relatywnie kosztowne techniki radiacyjne znajdują liczne zastosowania.
Referring to the celebrated 150th anniversary of Marii Skłodowskiej-Curie birthday this year, I recall a publication that gave rise to the radiation sterilization of disposable medical devices. In this work, the scholar also drew attention to the heterogeneous nature of the impact of ionizing radiation on matter. Only now, using the model of the ionization spurs, the experiments have been performed on radiation inactivation curves. Primary processes occurring in ionization nests are still subject to investigation. Particularly discussed are the mechanisms of the protective phenomenon observed in the radiation chemistry of organic compounds. It is translated both by the transfer of free radicals and energy or by charge. The research conducted by us suggests that the most likely mechanism is the travel of the excited state (energy). In this way, it is possible to explain the rather unlikely encounter of two radicals in the radiation crosslinking process. I would like to point out the role of multi-ionization spurs in the radiolysis of polymer materials. Also in this case, the protective effect of the aromatic compounds was experimentally confirmed. Benzene and its derivatives and higher aromatic hydrocarbons may partially dissipate the energy deposited in large LET spurs. It is important to note that the vast majority of natural and synthetic antioxidants are aromatic compounds. The unique features of the radiation treatment result from a relatively simple, efficient and easy to control how to create free radicals. For this reason, relatively expensive radiation techniques find many applications.
Źródło:
Postępy Techniki Jądrowej; 2017, 4; 21-25
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis of chitosan and carboxymethyl chitosan hydrogels by electron beam irradiation
Autorzy:
Czechowska-Biskup, Renata
Wach, Radosław
Stojek, Piotr
Kamińska, Martyna
Rosiak, Janusz M.
Ulański, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1034681.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Polskie Towarzystwo Chitynowe
Tematy:
PEGDA
carboxymethyl chitosan
chitosan
hydrogel
radiation crosslinking
Opis:
Solutions of chitosan (CS) and carboxymethyl chitosan (CMCS) were subjected to irradiation by electron beam in presence of a crosslinking agent (poly(ethylene glycol) diacrylate - PEGDA) in order to produce carboxymethyl chitosan- and chitosan-based hydrogels. PEGDA macromonomer itself undergoes simultaneous polymerization and crosslinking either in neutral water or in acidic medium. Acidic solutions of chitosan of 0.5, 1 and 2% can be effectively crosslinked with PEGDA to form a gel. Although CMCS undergoes radiation-initiated crosslinking only at high concentration in water (over 10%), the presence of PEGDA in solution facilitated hydrogel formation even at lower concentration of CMCS. Formation of CS and CMCS hydrogels required irradiation doses lower than those needed for sterilization, i.e. 25 kGy, in some cases even as low as 200 Gy. Sol-gel analysis revealed relatively high gel fraction of obtained hydrogels, up to 80%, and good swelling ability. Both parameters can be easily controlled by composition of the initial solution and irradiation dose. Possible mechanisms of crosslinking reactions were proposed, involving addition of the polysaccharide macroradicals to a terminal double bond of PEGDA.
Źródło:
Progress on Chemistry and Application of Chitin and its Derivatives; 2016, 21; 27-45
1896-5644
Pojawia się w:
Progress on Chemistry and Application of Chitin and its Derivatives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of hindered amine light stabilizers on the resistance of polypropylene towards ionizing radiation
Autorzy:
Przybytniak, G.
Mirkowski, K.
Rafalski, A.
Nowicki, A.
Legocka, I.
Zimek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/148686.pdf
Data publikacji:
2005
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
polypropylene
stabilizers
HALS
electron beam
apparent viscosity
nucleation agent
Opis:
The influence of hindered amine light stabilizers (HALSs) on physical and mechanical properties of irradiated and non-irradiated isotactic polypropylene (PP) was studied. The stabilizers under investigation were: Tinuvin 765 (T765) and Tinuvin 622 (T622) - derivatives of 1,2,2,6,6-pentamethyl piperidine and Chimassorb 944 (C944) - a derivative of 2,2,6,6-tetramethyl piperidine. It was found that the stabilizers reduce the amount of peroxyl radicals in the amorphous phase of PP. The irradiation with electron beam causes a drop of apparent viscosity both in the original and in the modified PP however the effect is smaller in the presence of HALSs. Admixture of T622 and T765 stabilizers increases the crystallization temperature of non-irradiated PP by about 8 10°C (measured by DSC) what results from the facilitated formation of a large number small microcrystals. It was concluded that HALSs initiate two opposite tendencies - chemical protection against damage initiated by free radicals and, simultaneously, physical enhancement of sensitivity towards irradiation by the increase of nucleation density. In the studied systems, the presence of maleic anhydride does not improve compatibility between the polymeric matrix and HALSs.
Źródło:
Nukleonika; 2005, 50, 4; 153-159
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of DRS and GC to study the effects of ionizing radiation on paper artifacts
Autorzy:
Głuszewski, W.
Boruc, B.
Kubera, H.
Abbasowa, D.
Powiązania:
https://bibliotekanauki.pl/articles/147776.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beam (EB)
disinfection
disinfestation
diffuse reflection spectrometry (DRS)
paper
gas chromatography
Opis:
Radiation preservation of objects of historical significance is an interesting proposition for museums, archives, libraries and private collectors. In this paper, we have limited ourselves to studying the effects of ionizing radiation on the paper. The radiation resistance of various grades of paper was examined in INCT. Irradiations were done by electron beam (10 MeV, 10 kW) and by gamma radiation (7 kG/h), for the purpose of comparison. Yields of hydrogen and absorption of oxygen were determined by gas chromatography (GC). For this purpose, the first time in an original way was used diffuse reflection spectroscopy (DRS). Described as the dose, dose rate, and lignin were found to affect degradation processes of cellulose. Examined the protective effect of lignin in the process of radiation degradation of paper. Proposed research methodology can be successfully applied to study other materials relevant to the conservation of works of art.
Źródło:
Nukleonika; 2015, 60, No. 3, part 2; 665-668
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Remediation of polluted waters and wastewater by radiation processing
Autorzy:
Sampa, M. H. O.
Takács, E.
Gehringer, P.
Rela, P. R.
Ramirez, T.
Amro, H.
Trojanowicz, M.
Botelho, M. L.
Han, B.
Solpan, D.
Cooper, W. J.
Emmi, S. S.
Wojnárovits, L.
Powiązania:
https://bibliotekanauki.pl/articles/147644.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beam
wastewater treatment
pesticides
dyes
degradation
radiation technology
Opis:
Application of radiation processing for drinking water, wastewater, and groundwater treatment is a cost effective process which may insure adequate availability of that resource worldwide. This paper summarizes the results of a Coordinated Research Project (organized by the IAEA) with participants from 10 countries with the purpose of describing the degradation mechanism of organic impurities, and establishing optimal treatment conditions. Decoloration, disinfection, microbiological and toxicological experiments are also mentioned. These experiments led to pilot plants and also to a large scale industrial realization of radiation technology.
Źródło:
Nukleonika; 2007, 52, 4; 137-144
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal, mechanical, and tribological properties of PTFE composite with 20% graphite content irradiated with an electron beam
Właściwości termiczne, mechaniczne i tribologiczne kompozytu PTFE z 20% zawartością grafitu napromieniowanego strumieniem elektronów
Autorzy:
Barylski, A.
Kaptacz, S.
Skoneczny, W.
Kupka, M.
Aniołek, K.
Powiązania:
https://bibliotekanauki.pl/articles/190691.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
PTFE
radiation modification
thermal properties
wear
modyfikacja radiacyjna
właściwości termiczne
zużycie
Opis:
The paper investigated the effect of irradiation with an electron beam of energy 10 MeV in doses of 26–156 kGy on polytetrafluoroethylene with a 20% graphite additive. The tests have shown that changes in thermal properties of the composite (heat of crystallization, melting point, and degree of crystallinity) directly affected mechanical properties and contributed to the significant improvement of tribological properties. Tribological tests were performed on a pin-on-disc (T-01) test stand and counter-specimens were made of 1H18N9T steel. The load applied in the friction pair was 1 and 2 MPa (20 and 40 N). A nearly fourfold reduction in linear wear compared to the initial state for a load of 1 MPa has been shown. On the other hand, a more than 20-fold decrease in wear was found during tribological tests when the load was increased to 2 MPa. The most advantageous results were obtained for specimens irradiated with a dose of 104 kGy, and irradiation with a higher dose led to the degradation of the polymer and caused its wear to increase again. The obtained results hold promise for a significant improvement of the operational life of friction couples that do not require lubrication used, for example, in air compressors and engines, and for the possible application of thus modified polymers in nuclear and space industries.
W artykule zbadano wpływ napromieniowania strumieniem elektronów o energii 10 MeV i dawkach 26–156 kGy na politetrafluoroetylen z 20% dodatkiem grafitu. Badania wykazały, że zmiany właściwości termicznych kompozytu (ciepło krystalizacji, temperatura topnienia, stopień krystaliczności) miały bezpośredni wpływ na właściwości mechaniczne oraz znaczną poprawę właściwości tribologicznych. Badania tribologiczne przeprowadzono na stanowisku trzpień-tarcza (T-01) przeciwpróbki wykonano ze stali 1H18N9T. Nacisk w węźle tarcia wynosił 1 i 2 MPa (20 i 40 N). Wykazano blisko 4-krotne ograniczenie zużycia liniowego w porównaniu do stanu wyjściowego dla nacisku 1 MPa. Przy zwiększeniu nacisku do 2 MPa podczas badań tribologicznych stwierdzono natomiast ponad 20-krotne zmniejszenie zużycia. Najkorzystniejsze wyniki uzyskano dla próbek napromieniowanych dawką 104 kGy; napromieniowanie większą dawką prowadziło do degradacji polimeru i ponownego wzrostu zużycia. Otrzymane wyniki rokują na znaczną poprawę trwałości eksploatacyjnej węzłów tarcia niewymagających smarowania stosowanych np. w sprężarkach powietrza, silnikach, a także możliwość zastosowania tak zmodyfikowanych polimerów w przemyśle jądrowym oraz kosmicznym.
Źródło:
Tribologia; 2017, 274, 4; 17-20
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sclerometric and Tribological Properties of Polytetrafluoroethylene with 40% Bronze Content Formed by Electron Beam Irradiation
Właściwości sklerometryczne i tribologiczne policzterofluoroetylenu z 40% zawartością brązu kształtowanego przez napromieniowanie strumieniem elektronów
Autorzy:
Barylski, Adrian
Aniołek, Krzysztof
Kaptacz, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/188628.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
PTFE with a 40% bronze content
radiation modification
wear micromechanism
sliding wear resistance ratio
wear
PTFE z 40% zawartością brązu
modyfikacja radiacyjna
mikromechanizm zużycia
wskaźnik odporności na zużycie ścierne
zużycie
Opis:
The paper focuses on the improvement of sclerometric and tribological properties of polytetrafluoroethylene (PTFE) with 40% bronze content implied by irradiation with an electron beam of 10 MeV and a power of 10 kW, in a dose of 26–156 kGy. The results of the study confirm that radiation modification of the PTFE-bronze composite causes structural changes induced by breaking of bonds in long PTFE chains and the branching of the polymer structure. As a result, an increase in such properties as the wear resistance ratio, Wβ, is observed. In addition, sclerometric tests have shown that, with an increase of the absorbed radiation dose, the groove-to-elevation area ratio changes during scratching, which indicates a change in the micromechanism of wear, i.e. the material undergoes ploughing. From the operating point of view, the most important were tribological tests, which were carried out on a pin-on-disc test stand (T-01). The tests showed a nearly fourfold reduction in wear at a load of 20 N and more than a threefold reduction at 40 N. Controlled radiation modification leads to improved properties of the PTFE-bronze composite, which may result in a wider range of its applications.
W pracy skoncentrowano uwagę na poprawie właściwości sklerometrycznych i tribologicznych politetrafluoroetylenu z 40% zawartością brązu implikowanych przez napromieniowanie strumieniem elektronów o energii wiązki 10 MeV i mocy 10 kW oraz dawce 26–156 kGy. Wyniki badań potwierdzają, że modyfikacja radiacyjna, jakiej poddany został kompozyt PTFE–brąz, powoduje zmiany strukturalne wywołane zrywaniem wiązań w długich łańcuchach PTFE oraz rozgałęzianiem się struktury polimeru. W konsekwencji obserwuje się wzrost takich właściwości jak wskaźnik odporności na zużycie Wβ. Badania sklerometryczne wykazały ponadto, że wraz ze wzrostem pochłoniętej dawki promieniowania zmienia się stosunek powierzchni wyżłobienia i wypiętrzenia podczas zarysowania, co świadczy o zmianie mikromechanizmu zużycia – materiał ulega bruzdowaniu. Z punktu widzenia eksploatacyjnego najważniejsze było przeprowadzenie badań tribologicznych, które wykonano na stanowisku trzpień–tarcza (T-01). Badania wykazały blisko 4-krotne ograniczenie zużycia przy zastosowaniu obciążenia 20 N oraz ponad 3-krotne przy zwiększeniu obciążenia do 40 N. Kontrolowana modyfikacja radiacyjna prowadzi do poprawy właściwości kompozytu PTFE–brąz, co może prowadzić do poszerzenia spektrum jego zastosowań.
Źródło:
Tribologia; 2019, 285, 3; 13-17
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The evaluation by means of microindentation and sclerometry of changes in properties after electron beam irradiation of polyethylene GUR 1050
Diagnozowanie metodą mikroindentacji i sklerometrii zmian właściwości po napromieniowaniu strumieniem elektronów polietylenu GUR 1050
Autorzy:
Barylski, A.
Cybo, J.
Maszybrocka, J.
Powiązania:
https://bibliotekanauki.pl/articles/187925.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
modyfikacja radiacyjna
obciążenie eksploatacyjne
odkształcenie polimeru
mikromechanizm zużycia ściernego
wskaźnik odporności na zużycie
twardość
moduł Younga
radiation modification
operational load
polymer deformation
abrasive wear micromechanism
resistance to wear ratio
hardness
Young's modulus
Opis:
With the aim to increase the resistance of GUR 1050 polyethylene to plastic deformation and abrasive wear, modification through radiation was applied. Compression tests of up to 300 MPa showed an increase in resistance to permanent deformation. This has been confirmed with microindentation and sclerometry tests. Scratch test indicated a lower tendency of the carved material to chipping than to uplift in all operational deformations. The domination of the micromechanism of the formation of ridges allows the material to retain a small decrease in resistance to wear. The parameters of microtests may be used for the purpose of the evaluation and selection of the polymers used in friction joints in medicine and technology.
W celu podwyższenia odporności polietylenu GUR 1050 na odkształcenie plastyczne i zużycie ścierne zastosowano modyfikację radiacyjną. Badania w zakresie naprężeń do 300 MPa wykazały wzrost odporności na deformację trwałą. Potwierdzono to testami mikroindentacyjnymi i sklerometrycznymi. Scratch test wykazał, że w całym zakresie odkształceń eksploatacyjnych występuje mniejsza skłonność do wykruszania materiału wyżłobionego niż do jego plastycznego wypiętrzania. Dominacja mikromechanizmu bruzdowania pozwala zachować niewielki spadek odporności na zużycie. Parametry mikrotestów mogą być wykorzystywane do diagnozowania i selekcji polimerów stosowanych w medycznych oraz technicznych węzłach tarcia.
Źródło:
Tribologia; 2012, 2; 23-29
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wzrostu gęstości usieciowania na właściwości mechaniczne i tribologiczne polimeru GUR 1050 dla endoprotezoplastyki kształtowanego przez napromieniowanie i odkształcenie plastyczne
Evaluation of increase crosslinking density on mechanical and tribological properties of GUR 1050 polyethylene used for endoprosthesis cups shaped by electron beam irradiation and plastic deformation
Autorzy:
Barylski, A.
Maszybrocka, J.
Powiązania:
https://bibliotekanauki.pl/articles/189300.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polietylen UHMW
modyfikacja radiacyjna
gęstość usieciowania
twardość
intensywność zużycia masowego i liniowego
UHMW polyethylene
radiation modification
crosslink density
hardness
intensity of mass wear
intensity of linear wear
Opis:
W celu zwiększenia odporności polietylenu GUR 1050 na odkształcenie plastyczne i zużycie ścierne przeprowadzono modyfikację radiacyjną z późniejszym odkształceniem plastycznym. Stosowano napromieniowanie elektronami o dawce 26-156 kGy i odkształcenie plastyczne o wartości ef= 0,2. Ze wzrostem dawki napromieniowania odnotowano znaczne zwiększenie gęstości usieciowania polimeru. Stwierdzono równocześnie, że występuje ścisły związek pomiędzy gęstością usieciowania a właściwościami mechanicznymi i tribologicznymi badanego polimeru. Potwierdzenie stanowi mniejsza wartość zużycia tribologicznego GUR 1050. Testy tribologiczne przeprowadzone na testerach T-05 i T-01 dowodzą, że wzrost gęstości usieciowania po napromieniowaniu strumieniem elektronów i po odkształceniu plastycznym polimeru powoduje 13-krotne obniżenie intensywności zużycia liniowego i 6-krotne obniżenie intensywności zużycia masowego w stosunku do polietylenów niemodyfikowanych. Uzyskane wyniki dowodzą skuteczności stosowanej technologii kształtowania polimeru, która rokuje możliwość wydłużenia czasu użytkowania panewek endoprotez.
Radiation modification with subsequent plastic deformation was conducted in order to increase the resistance of GUR 1050 polymer to plastic deformation and wear. Electron irradiation of 26-156 kGy dose and plastic deformation of the value of ef = 0.2 was applied. It was determined that the crosslink density increase along with the increase of the dose of radiation. It was also found that there is a close relationship between the crosslink density and the mechanical and tribological properties. Tribological tests conducted on the T-05 and T-01 testers have shown that the increase of crosslink density after electron beam irradiation and subsequent plastic deformation result in a 13-fold reduction in linear wear and a 6-fold reduction mass wear as compared to unmodified polyethylenes. The obtained results demonstrate the effectiveness of the technology used for the modification the polymer, which promises the possibility of extending the lifetime of endoprosthesis cups.
Źródło:
Tribologia; 2014, 2; 9-17
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności napromieniowania wiązką elektronów w aspekcie podwyższania odporności na zużycie polietylenów GUR 1020 i GUR 1050 stosowanych na panewki endoprotez
Evaluation of electron beam irradiation effectiveness in view of increasing wear resistance of GUR 1020 and GUR 1050 polyethylenes used for endoprosthesis cups
Autorzy:
Barylski, A.
Cybo, J.
Maszybrocka, J.
Czaja, P.
Powiązania:
https://bibliotekanauki.pl/articles/189986.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polietylen UHMW
modyfikacja radiacyjna
odkształcenie polimeru
twardość
moduł sprężystości
zużycie masowe i liniowe
UHMW polyethylene
radiation modification
polymer deformation
Young's modulus
hardness
mass wear
linear wear
Opis:
W celu zwiększenia odporności polietylenu GUR 1020 i GUR 1050 na odkształcenie plastyczne i zużycie ścierne przeprowadzono modyfikację radiacyjną. Stosowano napromieniowanie elektronami o dawce 26-156 kGy. Wraz ze wzrostem dawki napromieniowania odnotowano zwiększenie twardości i modułu sprężystości podłużnej. Stwierdzono również, że GUR 1050 (o ciężarze cząsteczkowym 9,2•106 g/mol) cechuje się 1,86 razy większą odpornością na trwałą deformację. Wskazuje to na ścisły związek właściwości polimerów z ciężarem cząsteczkowym, który dla GUR 1020 wynosi 5•106 g/mol. Potwierdzenie stanowi mniejsza wartość zużycia tribologicznego GUR 1050 niż GUR 1020, która już w stanie wyjściowym polimerów przekracza 20%. Testy tribologiczne przeprowadzone na testerach T-05 i T-01 dowodzą, że napromieniowanie elektronami (6×26 kGy) obu polimerów powoduje 4-krotne zmniejszenie zużycia w stosunku do polietylenów niemodyfikowanych. Uzyskane wyniki dowodzą skuteczności modyfikacji radiacyjnej, która rokuje możliwość wydłużenia czasu użytkowania panewek endoprotez.
Radiation modification was conducted in order to increase the resistance of GUR 1020 and GUR 1050 polyethylenes to plastic deformation and abrasive wear. Electron irradiation of 26-156 kGy dose was applied. It was determined that the hardness and longitudinal elasticity module increase along with the increase in the dose of radiation. It was also found that GUR 1050 (of a molecular weight of 9.2•106 g / mol) is characterised by a 1.86 times greater resistance to permanent deformation. This indicates a close relationship between the properties of polymers and molecular weight, which for the GUR 1020 is 5•106 g/mol. This is corroborated by a lower value of tribological wear of GUR 1050 compared to GUR 1020, which already exceeds 20% in the initial state of polymers. Tribological tests conducted on the T-05 and T-01 testers have shown that electron irradiation (6x26 kGy) of both polymers result in a four-fold reduction in wear as compared to unmodified polyethylenes. The obtained results demonstrate the effectiveness of radiation modification, which promises the possibility of extending the service life of endoprosthesis cups.
Źródło:
Tribologia; 2012, 4; 17-23
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-31 z 31

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies