Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "eksploatacja oczyszczalni" wg kryterium: Wszystkie pola


Wyświetlanie 1-7 z 7
Tytuł:
Modelowanie ryzyka w eksploatacji oczyszczalni ścieków
Modeling of risk in the operation of wastewater treatment plants
Autorzy:
Andraka, D.
Dzienis, L.
Powiązania:
https://bibliotekanauki.pl/articles/1819075.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
eksploatacja oczyszczalni
modelowanie ryzyka
reliability analysis
risk modeling
operation of wastewater treatment
Opis:
This paper presents the results of research using Monte Carlo simulation, which aim was to assess various aspects of the risk associated with operation of the wastewater treatment plant. First part of the research included modeling of wastewater treatment plant effluent quality (using BOD5 as the example and assuming log-normal distribution of the variable) together with inspection results (check of compliance with fixed standards). Monte Carlo simulations of annual operational cycles of the plant allowed for creation of nomographs showing relations between coefficient of reliability (ratio of mean value of BOD to the fixed standard), coefficient of variation (ratio of standard deviation to mean value of variable) and reliability of the plant (expressed as probability of effluent concentration lower than fixed standard) as well as risk of the negative inspection result (probability that number of inspected samples that do not comply with required quality of the effluent is greater than fixed standard). Using such nomographs plant operator can evaluate for example the target mean value of effluent concentration to achieve required reliability and acceptable risk. Another part of the study included simulation of the water quality in the river after the discharge of wastewater. Using static model of pollutants budget in a mixed water (river + wastewater) and implementing random values of variables into the model (according to Monte Carlo simulation rules) the variations of river water quality were observed. It was found that although mean values of variables (among them quality and quantity of the discharge) result in good mixed river water quality, the probability of temporary degradation of river quality is significantly high. The results of simulation show that capacity of the river to accept pollutants load should be taken into account together with predicted variations in wastewater discharges, when establishing rules for water disposal in the river basin.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 2; 1111-1125
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podsumowanie trzyletniej eksploatacji biogazowego zespołu kogeneracyjnego w oczyszczalni ścieków Warta S.A. w Częstochowie
A summary of three years’ operation of the biogas cogeneration set at the Warta S.A. waste treatment plant in Czestochowa
Autorzy:
Dużyński, A.
Powiązania:
https://bibliotekanauki.pl/articles/310661.pdf
Data publikacji:
2012
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
silnik biogazowy
zespół kogeneracyjny
CHP
eksploatacja przemysłowa
biogas engine
cogeneration set
combined heat and power (CHP)
commercial operation
Opis:
W pracy omówiono dotychczasową, trzyletnią eksploatację przemysłową biogazowego zespołu kogeneracyjnego z silnikiem GE JENBACHER typu JMS 316 GS-B.LC pracującego od końca grudnia 2008 roku w Oczyszczalni Ścieków WARTA S.A. w Częstochowie. Analizowano czas pracy i postojów zespołu CHP, liczbę rozruchów i jego dyspozycyjność, produkcję energii elektrycznej i ciepła, średnie godzinowe obciążenie elektryczne i cieplne zespołu CHP, bilans energii elektrycznej i ciepła oczyszczalni oraz stopień pokrycia zapotrzebowania oczyszczalni na energię elektryczną i ciepło produkcją własną, jednostkowe zużycie biogazu przez zespół kogeneracyjny, prace serwisowe i awarie zespołu kogeneracyjnego oraz uzyskane efekty ekonomiczne z eksploatacji tego zespołu. Praca jest kontynuacją wcześniejszych publikacji [3, 6, 7, 8, 9] i łącznie z nimi stanowi unikatowe kompendium wiedzy dla przyszłych eksploatatorów biogazowych zespołów CHP w postaci zbioru rzeczywistych danych eksploatacyjnych, jednego z najbardziej reprezentatywnych pod względem mocy elektrycznej (ok. 0,8 MW), biogazowego zespołu kogeracyjnego eksploatowanego w krajowych oczyszczalniach ścieków.
The paper discusses three years’ commercial operation to date of the Biogas Cogeneration (CHP) Set driven with the JMS 316 GS-B.LC GE JENBACHER type engine, which has been operating in the WARTA S.A. Sewage Treatment Plant of Czestochowa since the end of December 2008. The analysis covered the CHP Set’s operation and shutdown times, number of start-ups and availability, electric energy and heat generation, and average hourly electric and thermal load; the Sewage Treatment Plant’s electric energy and heat balance and the degree of coverage of its electric energy and heat demand by its own production; the unit biogas consumption by the CHP Set; the service work carried out on, and failures of the CHP Set; and the economic effects gained from the operation of the Set. The study is a continuation of the previous publications [3], [6], [7], [8], [9] and, jointly with them, constitutes a unique compendium of knowledge for future operators of CHP biogas sets in the form of a collection of actual operational data for one of the most representative biogas cogeneration sets operated in domestic sewage plants in terms of electric power (approx. 0.8 MW).
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2012, 13, 10; 43-51
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany w usuwaniu biogenów ze ścieków bytowo-gospodarczych po wieloletniej eksploatacji oczyszczalni roślinno-glebowej
Changes in nutrient removal from domestic sewage after 7 years exploitation of a plant-soil treatment plant
Autorzy:
Kuczewski, K.
Kwiecińska, K.
Kozdraś, M.
Powiązania:
https://bibliotekanauki.pl/articles/338947.pdf
Data publikacji:
2004
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
azot amonowy
azot ogólny
BZT5
efekt oczyszczania
eksploatacja
fosfor
ammonium nitrogen
BOD5
exploitation
total nitrogen
total phosphorus
treatment efficiency
Opis:
W artykule przedstawiono zmiany skuteczności oczyszczania ścieków bytowo-gospodarczych po siedmiu latach eksploatacji oczyszczalni roślinno-glebowej, przeznaczonej do oczyszczania ścieków pochodzących ze wsi Brzeźno. Budowa i zasada pracy tej oczyszczalni różni się istotnie od oczyszczalni roślinno-gruntowych. W artykule przedstawiono efekty oczyszczania, które uzyskano po oddaniu jej do eksploatacji, w rozbiciu na okres zimowy i letni, oraz po siedmiu latach pracy. Analizie poddano następujące wskaźniki zanieczyszczeń: BZT5, stężenie azotu amonowego, azotu ogólnego oraz fosforu. Z badań wynika, że średnia skuteczność oczyszczania ścieków po siedmiu latach eksploatacji oczyszczalni, uwzględniająca okres zimowy i letni, wynosi: BZT5 - ponad 99%, fosforu - 97,3%, azotu ogólnego - 95,9%, a azotu amonowego - 99,5%. Średnia zawartość fosforu w ściekach oczyszczonych w latach 2002-2003 wyniosła 0,3 mg P·dm-³, azotu ogólnego - 4,8 mg N·dm-³, a azotu amonowego - 0,3 mgNNH4·dm-³.
The article shows changes in the efficiency of domestic sewage treatment after 7 years exploitation of a plant-soil treatment plant. The plant purifies domestic sewage from the village Brzeźno. The construction and operation principles of the plant-soil treatment plant differ markedly from constructed wetlands. The paper shows results of operation in the winter and summer periods after 7 years exploitation. Analysed parameters included: BOD5, ammonium nitrogen, total nitrogen and total phosphorus. The studies show that the mean sewage treatment efficiency amounts 99% for BOD5, 97.3% for total phosphorus, 95.9% for total nitrogen and 99.5% for ammonium nitrogen. Mean concentrations of total phosphorus, total nitrogen and ammonium nitrogen in treated sewage in the years 2002-2003 were 0.3 mg·dm-³, 4.8 mg·dm-³ and 0.3 mg·dm-³, respectively.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2004, T. 4, z. 2a; 547-557
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zakres i częstotliwość prowadzenia badań i pomiarów w racjonalnej eksploatacji oczyszczalni ścieków
The extent and frequency of tests and measurements in the rational operation of wastewater treatment plant
Autorzy:
Kuśnierz, M.
Zarzycka, A.
Powiązania:
https://bibliotekanauki.pl/articles/297066.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
oczyszczanie ścieków
eksploatacja
kontrola jakościowa
kontrola ilościowa
wastewater treatment
operation
qualitative inspection
quantitative inspection
Opis:
Zgodnie z uregulowaniami prawnymi, praca oczyszczalni powinna zapewniać wymagany stopień oczyszczania ścieków w celu minimalizacji ich negatywnego wpływu na środowisko przyrodnicze. Jednocześnie w warunkach rosnących wymagań dotyczących stopnia oczyszczania ścieków i konieczności usuwania substancji biogennych osiągnięcie i utrzymanie założonego efektu ekologicznego ma ścisły związek z prawidłową eksploatacją oczyszczalni ścieków. Celem niniejszej pracy jest przedstawienie zagadnienia eksploatacji oczyszczalni ścieków z punktu widzenia zakresu i częstotliwości wykonywanych pomiarów i badań jakościowych oraz ilościowych ścieków i osadu czynnego.
The objective of the development of wastewater treatment technology is to ensure constant improvement of the efficiency of the operation of wastewater treatment plants. Pursuant to existing legal regulations, the operation of a wastewater treatment plant should ensure the required degree of wastewater treatment in order to minimise the negative impact of wastewater on the natural environment. At the same time, as the requirements concerning the degree of treatment of wastewater and the necessity to remove biogenic substances are becoming stricter, the possibility to achieve and maintain the required environmental results is strongly linked to the proper and systematic operation of wastewater treatment plants. The process of operation of wastewater treatment plants can be realised comprehensively, in numerous aspects. It encompasses more than the control over such technological processes as maintenance and repair of the facilities and the equipment connected thereto, but also technical inspection. Technical inspection, consisting in daily observations of the quality and quantity of the outflows and inflows, the condition of activated sludge and other parameters of a wastewater treatment plant, directly influences the improved efficiency of the operation of the plant. The aim of this study is to present the issue of operation of wastewater treatment plants in the aspect of the extent and frequency of actually taken measurements, qualitative and quantitative analyses of wastewater and activated sludge, based on a sample wastewater treatment plant of the capacity 2500 m3/d. The recording of data obtained in the course of such measurements provides the operator with the possibility to rationally manage the facility, to identify the statuses of operation of the wastewater treatment plant and to learn about the dynamics of changes and identify the causes of difficulties in the operation of technological processes. As a result of the conducted tests, it has been determined that the quantitative inspections carried out in the analysed wastewater treatment plant analyse the daily intensity of outflow of wastewater from secondary settlement tanks and the amount of created screenings, sand and sewage sludge. On the other hand, the facility does not record the amount of inflow of raw sewage, and the quantitative inspection is carried out only on raw sewage delivered in septic tanks. As for the quality inspections carried out in the wastewater treatment plant, it was noted that regular inspections are carried out only for basic pollution indicators, including: BOD5, COD, total nitrogen, ammonia nitrogen, nitrate nitrogen, total phosphorus and total suspended solids, which is compliant with existing legal requirements. During inspections of activated sludge chambers the amount of dissolved oxygen, temperature and sedimentation of activated sludge are analysed. The results of the conducted tests show that the extent of analyses and measurements carried out in the wastewater treatment plant reflects the scope of tests recommended for comprehensive inspection of technological parameters in such facilities only to a small extent, although it is compliant with the extent of measurements required pursuant to the permit required under the Water Law Act.
Źródło:
Inżynieria i Ochrona Środowiska; 2014, 17, 1; 63-73
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy eksploatacji Lesnej Oczyszczalni Sciekow z punktu widzenia ZPZ "Ilawa"SA w Ilawie
Autorzy:
Marszalek, A.
Powiązania:
https://bibliotekanauki.pl/articles/822193.pdf
Data publikacji:
1999
Wydawca:
Polskie Towarzystwo Leśne
Tematy:
eksploatacja
Lesna Oczyszczalnia Sciekow Ilawa
instalacja deszczowniana
Zaklady Przemyslu Ziemniaczanego Ilawa SA
oczyszczalnie gruntowo-roslinne
koszty
lesnictwo
lesne oczyszczalnie sciekow
Źródło:
Sylwan; 1999, 143, 10; 39-44
0039-7660
Pojawia się w:
Sylwan
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wstępne doświadczenia z eksploatacji zmodernizowanej małej oczyszczalni ścieków z filtrem żwirowym
The preliminary experience with the modernized small sewage treatment plant with a gravel filter
Autorzy:
Mucha, Z.
Gosek, K.A.
Powiązania:
https://bibliotekanauki.pl/articles/60920.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnie sciekow
oczyszczalnie male
filtry zwirowe
eksploatacja
oczyszczanie sciekow
efektywnosc oczyszczania
scieki oczyszczone
wskazniki zanieczyszczen
biochemiczne zapotrzebowanie tlenu
chemiczne zapotrzebowanie tlenu
zawiesina ogolna
azot amonowy
azot ogolny
fosfor ogolny
Opis:
W artykule przedstawiono wyniki badań efektywności oczyszczania oraz warunki pracy małej lokalnej oczyszczalni ścieków po jej modernizacji. Podstawowym kryterium przyjętym w projekcie modernizacji było zwiększenie przepustowości oraz efektywności usuwania zanieczyszczeń w istniejącym układzie technologicznym z grawitacyjnym przepływem ścieków przy założeniu minimalnych kosztów eksploatacji bez zużycia energii elektrycznej. Badana oczyszczalnia składa się z osadnika gnilnego z zainstalowanym w czasie modernizacji wydzielonym filtrem zapobiegającym wypływowi zawiesin z osadnika oraz filtra żwirowego do biologicznego oczyszczania. W czasie modernizacji zwiększona została powierzchnia filtra. Wykonane analizy jakości ścieków potwierdziły wysoką efektywność usuwania zanieczyszczeń organicznych (średnio ponad 90% dla wskaźnika BZT5 i ponad 85% dla wskaźnika ChZT) oraz zawiesin (średnio ponad 77%) w zmodernizowanej oczyszczalni.
The article analyses the efficiency of the treatment process in the small sewage treatment plant with a gravel filter, after its modernization. The basic criterion adopted in modernization was to increase the capacity and efficiency of the existing gravity flow system, assuming the minimal operating costs and no additional power consumption. The sewage treatment plant consists of a septic tank, with a separate filter installed during the modernization that keeps suspended solids in the septic tank and a gravel filter for biological treatment; the filter surface was increased during the modernization. The analysis of the effluent quality confirmed very high treatment efficiency of both organic compounds (average removal of BOD and COD was over 90% and 85%, respectively) and total suspended solids ( average removal above 77%) in the modernized wastewater treatment plant.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2013, 3/I
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane problemy wiejskich oczyszczalni sciekow na przykladzie obiektu w Tereszpolu
Autorzy:
Wasag, Z
Powiązania:
https://bibliotekanauki.pl/articles/808039.pdf
Data publikacji:
2001
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
eksploatacja
Tereszpol
obszary wiejskie
oczyszczalnie sciekow
koszty
Opis:
W pracy przedstawiono wybrane problemy wiejskiej oczyszczalni ścieków, po przekazaniu jej do eksploatacji, na przykładzie obiektu w Tereszpolu. Przeprowadzone badania dotyczyły zmian ilości oczyszczanych ścieków w zakresie od 20 do 120 m³·d⁻¹, zmian ich stężeń oraz nierównomierności dostaw ścieków dowożonych w stosunku do ogólnej ilości ścieków. Otrzymane wyniki wskazują na podwyższone stężenie zanieczyszczeń w ściekach surowych, bez względu na ich ilość. Powodem tego może być duży udział ścieków dowożonych (około 80%). Przy niewielkiej ilości ścieków 20 m³·d⁻¹ stężenia azotu amonowego, azotu ogólnego i fosforu ogólnego w ściekach po oczyszczalni przekraczają dopuszczalne wielkości. Stałe koszty eksploatacji oczyszczalni w około 80% uzależnione są od kosztów jej obsługi, natomiast koszty zmienne w największym stopniu uzależnione są od zużycia energii elektrycznej. Z badań wynika, że koszty eksploatacji oczyszczalni ściśle uzależnione są od ilości oczyszczanych ścieków. Przy 20 m³·d⁻¹ koszt oczyszczania 1 m³ wynosił 11,58 PLN, natomiast przy 120 m³·d⁻¹ - 2,44 PLN. Zatem im większa jest ilość ścieków, tym niższy jest koszt ich oczyszczania. Z przeprowadzonych badań wynika, że należy dążyć do pełnego obciążenia ściekami do zaprojektowanej przepustowości, co wpływa na zmniejszenie kosztów eksploatacji.
The paper concerns selected problems of rural sewage treatment plant on an example of the object in Tereszpol. The study included various quantities of sewage (from 20 to 120 m³·d⁻¹), changes in sewage concentration, as well as non-uniform sewage supply in relation to total sewage quantity. The results point out considerable pollutant concentration in crude sewage regardless of their quantity. It may be caused by considerable share of brought sewage (about 80%). At low sewage quantity 20 m³·d⁻¹ the concentrations of ammonia nitrogen, total nitrogen and total phosphorus exceeded tolerable limits. Fixed exploitation costs depend in 80% on the service, and the runming ones - on electric energy consumption. The study proved that the exploitation costs sewage treatment plant depend on sewage quantity. Purification costs per 1 m³ were at 20 m³·d⁻¹ - 11.58 PLN, and at 120 m³·d⁻¹ - 2.44 PLN. The more the sewage, the lower purification costs. It is concluded that there is a necessity to increase the load of sewage treatment to its flow capacity limits, as it improves purification quality, as well as reduces the costs.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 2001, 475; 173-178
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies