Tytuł:
Chemical passivation as a method of improving the electrochemical corrosion resistance of Co-Cr-based dental alloy
Autorzy:
Rylska, D.
Sokołowski, G.
Łukomska-Szymańska, M.
Powiązania:
https://bibliotekanauki.pl/articles/306992.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
odporność korozyjna
stop stomatologiczny
test elektrochemiczny
pasywacja chemiczna
corrosion resistance
dental alloys
electrochemical test
chemical passivation
Opis:
Purpose: The purpose of the study was to evaluate corrosion resistance of Wirobond C® alloy after chemical passivation treatment. Methods: The alloy surface undergone chemical passivation treatment in four different media. Corrosion studies were carried out by means of electrochemical methods in saline solution. Corrosion effects were determined using SEM. Results: The greatest increase in the alloy polarization resistance was observed for passive layer produced in Na2SO4 solution with graphite. The same layer caused the highest increase in corrosion current. Generally speaking, the alloy passivation in Na2SO4 solution with graphite caused a substantial improvement of the corrosion resistance. The sample after passivation in Na2SO4 solution without graphite, contrary to others, lost its protective properties along with successive anodic polarization cycles. The alloy passivation in Na3PO4 solution with graphite was the only one that caused a decrease in the alloy corrosion properties. The SEM studies of all samples after chemical passivation revealed no pit corrosion – in contrast to the sample without any modification. Conclusions: Every successive polarization cycle in anodic direction of pure Wirobond C® alloy enhances corrosion resistance shifting corrosion potential in the positive direction and decreasing corrosion current value. The chemical passivation in solutions with low pH values decreases susceptibility to electrochemical corrosion of Co-Cr dental alloy. The best protection against corrosion was obtained after chemical passivation of Wirobond C® in Na2SO4 solution with graphite. Passivation with Na2SO4 in solution of high pH does not cause an increase in corrosion resistance of WIROBOND C. Passivation process increases alloy resistance to pit corrosion.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 2; 73-78
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ technologii odlewania na jakość stomatologicznego stopu kobaltu
The influence of casting technologies on quality of dental cobalt alloy
Autorzy:
Surowska, B.
Beer, K.
Borowicz, J.
Veremchuk, I.
Powiązania:
https://bibliotekanauki.pl/articles/395529.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stop stomatologiczny
odlewanie odśrodkowe
odlewanie próżniowo-ciśnieniowe
wytrzymałość
dental alloy
centrifugal casting
vacuum-pressure casting
strength
Opis:
Metalowe protezy szkieletowe stwarzają problemy na etapie wykonawstwa oraz w czasie użytkowania, ulegając pękaniu. Jednym z najistotniejszych etapów wytwarzania, wpływającym na końcową jakość protezy, jest odlewanie metalowego szkieletu. W pracy dokonano analizy wpływu techniki odlewania na właściwości mechaniczne i strukturę stomatologicznego stopu CoCrMo. Zastosowano dwie metody odlewania: odlewanie odśrodkowe oraz próżniowo-ciśnieniowe. Porównano właściwości mechaniczne i strukturę odlewów. Nie stwierdzono istotności różnicy we właściwościach wytrzymałościowych (przy kryterium p<0,05) dla stopów odlewanych odśrodkowo oraz próżniowo. W strukturze zaobserwowano większy stopień porowatości odlewu i nieciągłości po granicach dendrytów na przełomach w materiale odlewanym odśrodkowo.
The essential reasons for failure during the frame dentures manufacture arise due to the clinical mistakes such as incorrectness or imprecision of design and non-adherence to technical procedures in prosthetic laboratory. The casting of metallic denture is one of the most important manufacture stage which has the influenceon denture quality. In this paper an influenceof casting method on mechanical properties and structure of CoCrMo dental alloy is carried out. Two methods of casting were used: centrifugal casting and vacuum pressure casting. The mechanical properties and microstructure of precision castings were compared. No statistically significantdifferences between mechanical properties of centrifugal and vacuum-pressure casting alloys with 100% and 50% new material were found (significancelimit p<0,05). Higher porosity and discontinuities on dendrite boundaries in centrifugal cast fractures than in vacuum-pressure cast fractures were observed.
Źródło:
Postępy Nauki i Techniki; 2011, 11; 81-88
2080-4075
Pojawia się w:
Postępy Nauki i Techniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Kinetics Of Ti-1Al-1Mn Alloy Thermal Oxidation And Charcteristic Of Oxide Layer
Charakterystyka warstw tlenkowych otrzymanych w procesie termicznego utleniania stopu Ti-1Al-1Mn
Autorzy:
Klimecka-Tatar, D.
Borkowski, S.
Sygut, P.
Powiązania:
https://bibliotekanauki.pl/articles/352549.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ti-alloy
artificial saliva
kinetic of oxidation
dental alloy
stop tytanowy
sztuczna ślina
kinetyka utleniania
stop dentystyczny
Opis:
The main goal of the study was to carry out the treatment of cyclic oxidation of Ti alloy (Ti-1Al-1Mn) in air atmosphere. Based on measurements of mass gain of titanium alloy samples (Ti-1Al-1Mn) the kinetic oxidation curves during cyclic annealing were determined. The oxidized surface of the titanium alloy was carefully observed with optical microscopy equipment and the geometrical development, shape and surface morphology were defined. The phase composition of the obtained oxide layers on the Ti-alloy with qualitative analysis of the X-ray were defined. Since titanium alloys are among the most widely used metallic materials in dental prosthetics the corrosion measurements in a solution simulating the environment of the oral cavity were carried out. The results confirmed that the used titanium alloy easily covered with oxides layers, which to some extent inhibit the processes of electrochemical corrosion in artificial saliva solution.
W pracy zaprezentowano wyniki badań nad kinetyką narastania warstw tlenkowych w efekcie cyklicznego termicznego utleniania stopu Ti-1Al-1Mn. Zabiegi utleniania przeprowadzono podczas sześciu 1-godzinnych cykli wygrzewania w atmosferze powietrza. Na podstawie pomiarów przyrostu masy próbek ze stopu tytanu (Ti-1Al-1Mn) wyznaczono krzywe kinetyki utleniania. W pracy przedstawiono również obserwacje mikroskopowe utlenionej powierzchni oraz na podstawie jakościowej analizy rentgenowskiej zidentyfikowano składniki strukturalne, będące produktem utleniania powierzchni. Z uwagi na fakt, że tytan i jego stopy są jednymi z najczęściej stosowanych w protetyce dentystycznej materiałami metalicznymi, przeprowadzono również testy korozyjne w środowisku imitującym warunki panujące w jamie ustnej człowieka. Wyniki potwierdziły, że tytan w podwyższonych temperaturach z łatwością pokrywa się warstwami tlenkowymi, które w pewnym zakresie hamują procesy korozyjne w roztworze sztucznej śliny.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 2A; 735-738
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wettability and Surface Free Energy of Ti(C,N) Coatings on Nickel-based Casting Prosthetic Alloys
Autorzy:
Banaszek, K.
Klimek, L.
Powiązania:
https://bibliotekanauki.pl/articles/381148.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dental alloy
wettability
contact angle
surface tension
surface free energy
stop dentystyczny
zwilżalność
kąt zwilżania
napięcie powierzchniowe
energia powierzchniowa swobodna
Opis:
The production process of prosthetic restorations runs in two stages. In the first stage, the prosthetic foundation is produced of metal alloys. In the second stage, a facing material is applied on the produced element. In both stages, the wettability is significantly important, as well as the free surface energy relating to it. The quality of the obtained cast depends on the surface phenomena occurring between the metal alloy and the material of which the casting mould is made. The performed examinations also point to a relation between the ceramics joint and the base, depending on the wetting angle. The aim of the presented paper was to examine influence of the composition of a Ti(C,N)-type coating on bases made of the Ni-Cr prosthetic alloy on the wettability and the surface free energy. The test material were disks made of the Ni-Cr alloy with the diameter of 8 mm. The disks were divided into five groups, which were covered with Ti(C,N) coatings, with different amounts of C and N in the layer. In order to determine the surface free energy (γs), the wetting angle was measured. Two measure liquids were applied: distilled water and diiodomethane. The obtained results of the measurements of the water-wetting angles suggest that together with the increase of the ratio of nitrogen to carbon in the Ti(C,N) coating, the surface hydrophobicity increases as well. In all the samples, one can see a large difference between the energy values of the polar and the apolar components. The high values of the polar components and the low values of the apolar ones make it possible to conclude that these surfaces exhibit a greater affinity to the polar groups than to the apolar ones. On the basis of the analysis of the surface free energy, one can state that covering the alloy with Ti(C,N)-type coatings should not decrease the adhesion of the ceramics to the alloy, whereas TiC coatings should lead to the latter’s improvement. Due to their hydrophilicity, TiC coatings should decrease the adhesion of bacteria to the surface and hinder the formation of a bacterial biofilm.
Źródło:
Archives of Foundry Engineering; 2015, 15, 3; 11-16
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zachowanie korozyjne stopów kobaltu w roztworze sztucznej śliny
Corrosion Behaviour of Cobalt Alloys in Artificial Saliva Solution
Autorzy:
Loch, J.
Krawiec, H.
Powiązania:
https://bibliotekanauki.pl/articles/380504.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odporność na zużycie
właściwości korozyjne
stop stomatologiczny
stop kobaltu
sztuczna ślina
wear resistance
corrosion properties
dental alloy
cobalt alloy
artificial saliva
Opis:
Stopy kobaltu są materiałami wykorzystywanymi w medycynie oraz stomatologii ze względu na swoje idealne połączenie dobrych właściwości wytrzymałościowych, korozyjnych oraz biokompatybilność. Obecnie stopy kobaltu są jednymi z najbardziej atrakcyjnych materiałów metalowych, używanych do wyrobu implantów w tym: sztucznych stawów biodrowych, kolanowych, dysków miedzykręgowych, śrub zabezpieczających złamania. W stomatologii wykonuje się z nich wszelkiego rodzaju wkręty, stanowiące podstawę do przytwierdzania zębowych protez ceramicznych. Ze względu na powszechne wykorzystanie stopów kobaltu w stomatologii, w pracy podjęto badania elektrochemiczne wybranych stopów kobaltu: Co-Cr-Mo i Co-Cr-W, których celem było określenie właściwości korozyjnych podczas ekspozycji w fizjologicznym roztworze sztucznej śliny, w temperaturze 37 °C, pH = 8,3 i swobodnym dostępie tlenu.
Cobalt alloys are used in medicine and dentistry due to perfect combination of their high strength, corrosion resistance and biocompatibility. Currently, cobalt alloys are among the most attractive metallic materials used to manufacture such implants as artificial hip joints, knee joints, intervertebral discs, screws securing the fracture. All kinds of screws used in dentistry for basic fixing of ceramic dental prostheses are made from cobalt alloys. Widespread use of cobalt alloys in dentistry is the reason for electrochemical research on selected cobalt alloys (Co-Cr-Mo and Co-Cr-W). The aim of the research was to determine the corrosion when the alloy is exposed to physiological artificial saliva solution at the temperature of 37 °C, pH = 8.3 and in aerated solution.
Źródło:
Archives of Foundry Engineering; 2013, 13, 3 spec.; 101-106
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructural characterisation of Co-Cr-Mo casting dental alloys
Autorzy:
Szala, M.
Beer-Lech, K.
Gancarczyk, K.
Kilic, O.
Pędrak, P.
Özer, A.
Skic, A.
Powiązania:
https://bibliotekanauki.pl/articles/103216.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
casting
microstructure
Co-Cr-Mo
biomaterials
dendritic structure
phase composition
chemical composition
dental cobalt alloy
Opis:
The study compares the microstructure of three commercial dental cobalt matrix alloys with related chemical composition declared by the manufacturer. Casts were produced with lost wax method, then melted and casted with centrifugal induction casting machine. The Co-Cr-Mo alloys were casted according to the manufacturers procedure. The samples’ chemical composition and phase composition, respectively, using WDXRF (Wavelength Dispersive X-Ray Fluorescence) and XRD (X-ray Diffarction) methods were analysed. Casts microstructure by mean of LOM (Light Optical Microscopy), SEM (Scanning Electron Microscopy) and EDS (Energy Dispersive X-ray Spectroscopy) were investigated. Vickers hardness HV10 was measured. Quantitative microstructure evaluation was performed by means of computer image processing. The results of the chemical composition indicate the high stability of the chemical composition for alloy A. In case of alloys B and C, there was a significant difference in carbon content. Quantitative differences in image of microstructure between of castings A and B, C were noticed. The greater amount of precipitates was recorded for castings with higher carbon content. In all investigated castings, the presence of β matrix solution and M23C6 carbide precipitations was found.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 76-82
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on resistance to corrosive wear of dental CoCrMo alloy containing post-production strap
Badanie odporności na zużycie korozyjne stomatologicznego stopu CoCrMo zawierającego złom poprodukcyjny
Autorzy:
Beer-Lech, K.
Surowska, B.
Powiązania:
https://bibliotekanauki.pl/articles/1365888.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
corrosive wear
cobalt alloys
post-production scrap
zużycie korozyjne
stopy kobaltu
złom poprodukcyjny
Opis:
Use of metal base dental prostheses is accompanied by not only wear due to biomechanical loads that occur during the process of chewing, but also by corrosive wear occurring in aggressive oral environment. Corrosive wear of metal elements of prosthesis may result in excluding it from further use by the occurrence of allergic or even carcinogenic reactions in patient, resulting from the release of toxic metal ions into the body. A common practice in prosthetic laboratories used in order to reduce production costs of dental prostheses is using so-called post-production scrap to subsequent castings. This scrap constitute the elements of casting channels, defectively made skeletons of prostheses or metal residues after prosthetic treatment. Use of post-production scrap to manufacture components to fulfill such high performance criteria (presence of complex biomechanical loads), and in particular taking into account the evaluation of biocompatibility, is the subject of discussion not only in the environment of scientists, but also the producers of dental alloys.The aim of the study was to investigate resistance to corrosive wear of dental cobalt alloy containing post-production scrap. The commercial dental alloy Wironit extra-hard with cobalt matrix has been used in this research. The study was based on a conducted polarity by means of potentiodynamic method in a solution of artificial saliva. Tested alloy samples, containing different percentage intake of post-production scrap, were cast by two casting methods - centrifugal and vacuum-pressure. Average values of parameters of Wironit extra – hard alloy resistance to corrosive wear: corrosion potential – Ecor , corrosion current Icor, polarisation resistance Rpol and pitting potential – Epit were determined. In order to assess alloy surface after corrosion microscopic observation was made. The results of research confirm high resistance of alloy to corrosive wear in environment of artificial saliva. Castings made using centrifugal methods provide lower current density in the passive state than those carried out by vacuum – pressure method, which suggests greater durability of passive layer confirmed by analysis of microstructure of samples after corrosion. Determination of correlation between content of post-production scrap and resistance to corrosion is ambiguous.
Eksploatacji stomatologicznych protez na podbudowie metalowej towarzyszy nie tylko zużycie wskutek obciążeń biomechanicznych, występujących podczas procesu żucia, ale również zużycie korozyjne mające miejsce w agresywnym środowisku jamy ustnej. Zużycie korozyjne metalowych elementów protezy skutkować może wyłączeniem jej z dalszego użytkowania wskutek wystąpienia u pacjenta reakcji alergicznych lub nawet kancerogennych, będących rezultatem uwalniania do organizmu toksycznych jonów metali. Częstą praktyką w laboratoriach protetycznych stosowaną w celu obniżania kosztów produkcji protez jest stosowanie tzw. złomu poprodukcyjnego do kolejnych odlewów. Złom ten stanowią elementy kanałów odlewniczych, wadliwie wykonane szkielety protez bądź metalowe pozostałości po obróbce protetycznej. Zastosowanie złomu poprodukcyjnego do wytwarzania elementów mających spełniać tak wysokie kryteria eksploatacyjne (występowanie złożonego stanu obciążeń biomechanicznych), a zwłaszcza biorąc pod uwagę ocenę biokompatybilności otrzymanych wyrobów, jest tematem dyskusyjnym nie tylko w środowisku naukowców, ale również i samych producentów stopów stomatologicznych. Celem pracy było zbadanie odporności na zużycie korozyjne stomatologicznego stopu kobaltu zawierającego złom poprodukcyjny. Do badań zastosowano komercyjny stop stomatologiczny Wironit extra – hard na osnowie kobaltu. Badanie polegało na przeprowadzeniu polaryzacji metodą potencjodynamiczną w środowisku roztworu sztucznej śliny. Próbki stopu poddane badaniu, zawierające różny udział procentowy złomu poprodukcyjnego, odlane zostały dwiema metodami odlewniczymi - odśrodkową i próżniowo-ciśnieniową. Wyznaczono średnie parametrów określających odporność stopu Wironit extra – hard na zużycie korozyjne: potencjał korozji – Ekor, prąd korozji Ikor, opór polaryzacyjny Rpol i potencjał przebicia – Epit. W celu oceny powierzchni stopu po korozji dokonano obserwacji mikroskopowych. Wyniki badań potwierdzają dużą odporność stopu na zużycie korozyjne w środowisku sztucznej śliny. Odlewy wykonane za pomocą metody odśrodkowej cechują się niższą gęstością prądu w stanie pasywnym niż te wykonane metodą próżniowo – ciśnieniową, co sugeruje większą trwałość warstwy pasywnej potwierdzoną analizą mikrostruktury próbek po korozji. Wyznaczenie zależności pomiędzy zawartością złomu poprodukcyjnego a odpornością na korozję jest niejednoznaczne.
Źródło:
Eksploatacja i Niezawodność; 2015, 17, 1; 90-94
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ recyklingu na strukturę i właściwości wytrzymałościowe odlewniczego stopu kobaltu stosowanego w stomatologii
Effect of recycling on structure and mechanical properties of dental casting cobalt alloy
Autorzy:
Surowska, B.
Beer, K.
Bieniaś, J.
Powiązania:
https://bibliotekanauki.pl/articles/386681.pdf
Data publikacji:
2011
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
stomatologia
recykling
wytrzymałość
kobalt
stop
stomatology
recycling
strength
cobalt
alloy
Opis:
Pękanie metalowego szkieletu protez częściowych jest dość częstym przypadkiem w protetyce stomatologicznej. Główną przyczyną tego typu uszkodzenia jest niewłaściwa jakość odlewu. Ze względów ekonomicznych producenci stopów dopuszczają stosowanie złomu metalowego jako części wsadu. W pracy dokonano analizy wpływu recyklingu na właściwości mechaniczne i strukturę odlewniczego stopu kobaltu. Zastosowano odlewanie próżniowo-ciśnieniowe do wsadów zawierających 0%, 25% oraz 50% złomu pochodzącego z kanałów wlewowych i stożków odlewniczych stopu CoCrMo. Porównano właściwości mechaniczne i strukturę odlewów. Stwierdzono, że wytrzymałość mechaniczna wszystkich stopów jest niższa niż średnia deklarowana przez producenta. Przełomy mają charakter kruchy, z wyraźnie widoczną strukturą dendrytyczną. Wraz ze wzrostem udziału materiału wtórnie przetapianego rośnie niejednorodność struktury na przekroju poprzecznym próbek oraz gęstość mikropęknięć w objętości dendrytów po próbie rozciągania.
Cracking of the frame partial dentures is frequent case in dental prosthodontics. The wrong quality of cast is the main reason for this type of damage. The alloys producers allow to use the scrap metal as the part of charge on account of economy. In this paper an influence of recycling on mechanical properties and structure of Co-Cr-Mo dental alloy is carried out. The vacuum pressure casting was used. The charges consist of 0%, 25% and 50% of scrap metal from gate assembly. The mechanical properties and microstructure of precision castings was compared. It was found that all casts strength was lower than average one declared by producer. The brittle fractures and dendritic structures was observed. The structure inhomogeneity and density of microcracks inside dendrites after tension test increase along with percentage growth of scrap metal.
Źródło:
Acta Mechanica et Automatica; 2011, 5, 3; 119-123
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Remelting on the Quality of Prosthetic Cobalt Alloys
Autorzy:
Nadolski, M.
Łągiewka, M.
Konopka, Z.
Zyska, A.
Golański, G.
Powiązania:
https://bibliotekanauki.pl/articles/382647.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cobalt alloy
centrifugal casting
lost wax technology
dental prosthetics
stop kobaltu
odlewanie odśrodkowe
metoda wytapianych modeli
protetyka stomatologiczna
Opis:
A commercial cobalt alloy applied in dental prosthetics was investigated. The scope of the work included the microstructure analysis, performance examination (tensile strength, microhardness, corrosion resistance), and dilatometric examination. The investigated alloy after a single remelting was characterised by higher tensile strength and hardness. There were not found the definite results with regard to the corrosion resistance of the examined materials. No significant change occurred in the coefficient of thermal expansion.
Źródło:
Archives of Foundry Engineering; 2015, 15, 3 spec.; 53-58
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quality of Ni-Cr-Mo casting dental alloys in terms of Ni and Mo contents changing
Autorzy:
Klimecka-Tatar, D.
Powiązania:
https://bibliotekanauki.pl/articles/114960.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
Ni-Cr-Mo alloy
dental restorations
Ni alloy
microstructure
stop Ni-Cr-Mo
uzupełnienia protetyczne
stop Ni
Opis:
This paper presents results of microscopic examination and properties comparison of commercial Ni-Cr-Mo alloys (Remanium G-soft and Remanium CSe alloy) commonly used in dental laboratories. The study confirmed that a small change in the content of the basic components of the alloy, has a very large impact on the structural construction of alloy, and consequently on the properties of the alloy. The increased molybdenum content favors the segregation of the components and thus makes it possible to apply the Ni61Cr26Mo11Si1.5(Fe,Co,Ce)x (x < 1) as a based material for prosthetics substructure veneered with ceramic material.
Źródło:
Zeszyty Naukowe. Quality. Production. Improvement; 2014, 1 (1); 121-130
2544-2813
Pojawia się w:
Zeszyty Naukowe. Quality. Production. Improvement
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Dental Prostheses Cast and Sintered by SLM from Co-Cr-Mo-W Alloy
Autorzy:
Myszka, D.
Skrodzki, M.
Powiązania:
https://bibliotekanauki.pl/articles/380544.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
microstructure
dental prosthesis
precision investment casting
selective laser melting
dimensional accuracy
proteza zębowa
odlewnictwo precyzyjne
przetapianie laserowe selektywne
dokładność wymiarowa
Opis:
The article presents the results of a comparative analysis of the metal substructure for dental prosthesis made from a Co-Cr-Mo-W alloy by two techniques, i.e. precision investment casting and selective laser melting (SLM). It was found that the roughness of the raw surface of the SLM sinter is higher than the roughness of the cast surface, which is compensated by the process of blast cleaning during metal preparation for the application of a layer of porcelain. Castings have a dendritic structure, while SLM sinters are characterized by a compact, fine-grain microstructure of the hardness higher by about 100 HV units. High performance and high costs of implementation the SLM technology are the cause to use it for the purpose of many dental manufacturers under outsourcing rules. The result is a reduction in manufacturing costs of the product associated with dental work time necessary to scan, designing and treatment of sinter compared with the time needed to develop a substructure in wax, absorption in the refractory mass, casting, sand blasting and finishing. As a result of market competition and low cost of materials, sinter costs decrease which brings the total costs related to the construction unit making using the traditional method of casting, at far less commitment of time and greater predictability and consistent sinter quality.
Źródło:
Archives of Foundry Engineering; 2016, 16, 4; 201-207
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applications of digital analyzer to characterizing the structures of Ni-Cr-Mo dental casting alloys
Autorzy:
Klimecka-Tatar, D.
Powiązania:
https://bibliotekanauki.pl/articles/114752.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
digital analysis
Ni-Cr-Mo alloy
Ni alloy
analiza cyfrowa
stop Ni-Cr-Mo
stop Ni
stopy dentystyczne
Opis:
This paper presents the possibility of carrying out a structural quantitative analysis of the alloys commonly used in dentistry. On the basis of microscopic observation and digital treatments (LUT and binarization) it was possible to determine the contribution of the phase structure of the Ni-Cr-Mo alloy. The results revealed that differences in the chemical and structural composition of Remanium dental alloys, easily identifiable on the basis of digital image analysis.
Źródło:
Zeszyty Naukowe. Quality. Production. Improvement; 2014, 1 (1); 88-98
2544-2813
Pojawia się w:
Zeszyty Naukowe. Quality. Production. Improvement
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Siła wiązania układu metal-ceramika w zastosowaniach stomatologicznych
Shear bond strength of ceramic – metal system for the dental applications
Autorzy:
Lubas, M.
Jasiński, J.
Jeziorski, L.
Powiązania:
https://bibliotekanauki.pl/articles/285176.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
układ metal-ceramika
stop kobaltowo-chromowy
zastosowania stomatologiczne
ceramic-metal system
cobalt-chromium alloy
dental applications
Opis:
W pracy przedstawiono wyniki badań stanu powierzchni próbek ze stopu kobaltowo-chromowego po przeprowadzanej obróbce mechanicznej z zastosowaniem różnych mediów piaskujących (mieszanina Al2O3+SiO2 oraz tradycyjnie stosowany piasek korundowy - Al2O3).Wpływ mechanicznej obróbki na jakość po-wierzchni, określono na podstawie badań topografii powierzchni próbek metalicznych z zastosowaniem mikroskopu sił atomowych AFM. Przeprowadzone badania pozwoliły określić podstawowe parametry chropowatości Ra i Rz. Ponadto określono wpływ medium piaskującego na trwałość połączenia uzyskanych próbek ceramiczno-metalowych, stosując mikroskopię świetlną, skaningową oraz próbę zginania dwupunktowego. Wyniki badań wytrzymałościowych wykazały większą wytrzymałość połączenia dla próbek piaskowanych mieszaniną Al2O3 i SiO2- σ2=54MPa (σ1=49MPa - próbki piaskowane Al2O3).
In this paper the influence of sanding material type used for sand blasting mechanical treatment of cobalt-chromium alloy for metal to porcelain shear bond strength was investigated. Corundum sand (Al203) and corundum (Al203)+silica (SiO2) mixture was used as a sand blasting process medium. Metallic elements surface topography after sand blasting process was determined using AFM microscopy. Basic roughness parameters, Ra and Rz were also investigated. Two specimens series were tested for a shear load on a universal testing machine using a 1mm/min crosshead speed. Each series single specimen was tested on a tirpoint bending machine for failure stress (MPa) de-termination and observed using SEM microscopy. Results showed higher metal to porcelain bond strength for samples that were sand blasted with corundum Al203+silica SiO2 mixture, σ2=54MPa, as compared with corundum sand blasted samples σ1=49MPa.
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 119-122
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of gold with titanium alloy weldability in conditions of a dental technique laboratory
Autorzy:
Jania, G.
Żmudzki, J.
Topolska, S.
Powiązania:
https://bibliotekanauki.pl/articles/24200598.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
titanium alloy
gold
laser welding
prosthetic
implant denture
microstructure
stop tytanu
złoto
spawanie laserowe
protetyka
proteza implantu
mikrostruktura
Opis:
Purpose: In dental practice, there is necessary to weld gold with titanium under the conditions of a dental technique laboratory, which is difficult. The aim was to assess the weldability of pure gold with the titanium alloy Ti6Al4V using a prosthetic laser welding machine. Design/methodology/approach: Gold wire in a diameter of 0.4 mm made with the use of a jewellery drawbar (GOLDPORT, Szczecin, Poland) was welded to a titanium alloy Ti6Al4V substrate of dental implant abutment screw (MegaGen). Dental laser welding parameters (Bego Laser Star T plus) were 230 V; 6.5 ms; 2.5 Hz; laser spot 0.3 mm, and argon blow. Samples were included in resin, ground (500-4000 SiC), polished (Al2O3 suspension) and etched (Kroll solution) per 20 s before observation under a light microscope. Findings: There were well-welded and poorly joined zones. The discontinuities and voids there were not visible or sparse next to the initial weld point. Dendritic structure at well-welded remelting zones and two-phase microstructure of titanium and Ti3Au phase were found. The heat-affected zone was about of 20 microns. Research limitations/implications: Light microscopy was used, and precise phase identification required further investigations. Weld strength assessment requires further micro-hardness and load-bearing ability tests. Weldability concerns the model system with pure gold. Practical implications: In the case of elements with dimensions below 0.4 mm, the use of a laser with a smaller spot should be considered for better control of the remelting zone and mechanical positioning of the elements in order to stabilize and avoid discontinuities and voids. Originality/value: Prosthetic laser welding with a laser spot about of 0.3 mm allows to obtain well-welded parts of 0.3 mm in diameter under stable stitching conditions and higher than 0.4 mm in dimensions.
Źródło:
Archives of Materials Science and Engineering; 2022, 118, 1; 36--41
1897-2764
Pojawia się w:
Archives of Materials Science and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ technologii wytwarzania na właściwości materiałowe stopu kobaltu wykorzystywanego w protetyce dentystycznej
The effects of production technology on cobalt alloy material properties used in dental techniques
Autorzy:
Litwinko, M.
Grądzka-Dahlke, M.
Powiązania:
https://bibliotekanauki.pl/articles/99335.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
stop kobaltu
protetyka dentystyczna
odlewnictwo
SLM
cobalt alloy
prosthetic dentistry
foundry
Opis:
Jednym z etapów w procesie powstawania protetycznego uzupełnienia dentystycznego jest realizacja zaprojektowanego kształtu protezy w tworzywie metalowym. Jest krokiem istotnym a zarazem narażonym na wiele niepowodzeń. W artykule przedstawiono porównanie dwóch metod wykonawstwa techniki dentystycznej: tradycyjnego odlewania oraz nowoczesnej SLM. Badaniom poddano protetyczny stop kobaltu w postaci prostopadłościennych próbek.
One of the stages in the process of restoration of dental prostheses is the shape which was designed to achieve a complement in the metal. It is an important step and exposed to many setbacks. The article gives a comparison of two methods of dental technology: traditional casting and modern SLM. The test was in the form of a cobalt alloy prosthetic square bales samples.
Źródło:
Aktualne Problemy Biomechaniki; 2014, 8; 99-102
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical aspects of casting and their effect on the quality of Remanium CSE dental alloys
Autorzy:
Klimecka-Tatar, D.
Radomska, K.
Pawłowska, G.
Powiązania:
https://bibliotekanauki.pl/articles/111804.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
casting alloy
quality
surface roughness
odlewy ze stopu
jakość
chropowatość powierzchni
Opis:
The study concerns on investigation of Remanium CSE alloy, one of the dental alloys used in metal-ceramic connection preparation. The alloys based on Ni-Cr-Mo are widely used in dental engineering because of their high mechanical, tribological properties as well as high corrosion resistance. The tested alloy has been processed in three ways – it has been remelted and then casted using three technologies commonly used in dental laboratories, i.e. with: oxy-acetylene burner (1), induction furnace (2) and Volts arc (3). The aim of the study was to evaluate the effect of the melting and casting techniques on the mechanical strength and stereometric surface properties. The results revealed that the quality of Remanium CSe dental alloys significantly depend on the method of the material processing.
Źródło:
Production Engineering Archives; 2016, 10, 1; 38-41
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena strukturalna wybranych stopów Cr-Ni na podstawie badań metalograficznych
Analysis of the structures of selected chrome-nickel alloys based on macroscopic investigations
Autorzy:
Partyka, P.
Hajduga, M.
Powiązania:
https://bibliotekanauki.pl/articles/99035.pdf
Data publikacji:
2008
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
stop Cr-Ni
stop chromowo-niklowy
badanie metalograficzne
analiza makrostopowa
technika dentystyczna
Cr-Ni alloy
chrome-nickel alloy
metallographic examination
macroscopic analysis
dental technique
Opis:
Praca zawiera analizę makroskopową struktur stopów chromowo- niklowych wykorzystywanych w technice dentystycznej. Obserwacja okiem nieuzbrojonym oraz przy niewielkim powiększeniu pozwala na wysunięcie wniosków na temat jakości odlanego stopu, a w przypadku wystąpienia nieprawidłowości strukturalnych umożliwia określenie przyczyn powstałych wad. Wykazano, iż prawidłowa pod względem technologicznym konstrukcja odlewów oraz poprawne przeprowadzenie procesów technologicznych są czynnikami umożliwiającymi uzyskanie prawidłowej struktury odlewu.
The thesis contains macroscopic analysis of the structures of samples of chrome-nickel used in dental technique. Observation of etched samples was conducted by unarmed eye as well as at small magnification, up to 30 times. Macroscopic tests allow for drawing conclusions about the quality of a cast alloy, and in case of occurrence of structural irregularities, they permit identification of the causes for the defects. It was demonstrated that technologically correct structure of casts and correct conduct of technological processes are factors that facilitate obtaining a correct structure of the cast.
Źródło:
Aktualne Problemy Biomechaniki; 2008, 2; 123-128
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of finishing process on the surface quality of Co-Cr-Mo dental alloys
Autorzy:
Klimecka-Tatar, D.
Radomska, K.
Pawłowska, G.
Powiązania:
https://bibliotekanauki.pl/articles/111889.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
biomedical engineering
surface roughness
casting alloy
quality
inżynieria biomedyczna
chropowatość powierzchni
odlewy ze stopu
Opis:
Preparatory procedures for the material have a significant influence on the surface stereometry of the material. This study investigated the effect of the electropolishing process on the surface quality of metallic prosthetic constructions based on Co-Cr-Mo alloys. It has been found that the process of electropolishing prevents to excessive development of the surface of a material and consequently improves surface quality.
Źródło:
Production Engineering Archives; 2016, 12, 3; 19-21
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szybkość utleniania w ocenie struktury dla stopów protetycznych
Oxidation speed in the structure evaluation for prosthetic alloys
Autorzy:
Hajduga, M.
Kalukin, B.
Kalukin, A.
Powiązania:
https://bibliotekanauki.pl/articles/98977.pdf
Data publikacji:
2008
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
proteza dentystyczna
implantacja
stop protetyczny
odporność na korozję
dental prosthesis
implantation
prosthetic alloy
corrosion resistance
Opis:
Implantacja w organizmie ludzkim materiałów metalicznych, w każdym przypadku obarczona jest wystąpieniem zjawisk korozyjnych. Dotyczy to również sytuacji, kiedy wprowadzony jest tylko jeden stop. Całość konstrukcji nie posiada jednakowego otoczenia, co wiąże się z wystąpieniem różnicy potencjałów. Celem pracy, jest identyfikacja zmian, zachodzących w strukturze konstrukcji metalicznej, której elementy, działając w jednym organizmie, mają różne otoczenie. Zakres pracy obejmuje pomiar różnicy potencjałów, materiałów metalicznych o geometrii prostopadłościanów, z których jeden jest nieosłonięty zaś drugi w pewnej części, pokryty PMMA. Jak również badania metalograficzne mikroskopowe tych prostopadłościanów a także części protezy „szkieletowej”, po długotrwałym użytkowaniu w ludzkim organizmie żywym.
The implantation of metallic materials into the human body always entails the risk of corrosion phenomena. This also refers to cases when only one alloy is introduced. The whole structure does not have the same surroundings, which is connected with the occurrence of potential differences. The purpose of the paper is to identify changes occurring in the metallic structure whose elements operating in one human body have different surroundings. The scope of the paper covers the measurement of potential differences of metallic materials-cuboids - one being uncovered and the other, at some height, covered with PMMA, as well as metallographic microscopic examination of the cuboids and the frame denture part after prolonged use in a living human body.
Źródło:
Aktualne Problemy Biomechaniki; 2008, 2; 59-64
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructural and micromechanical tests of titanium biomaterials intended for prosthetic reconstructions
Autorzy:
Ryniewicz, A. M.
Bojko, Ł.
Ryniewicz, W. I.
Powiązania:
https://bibliotekanauki.pl/articles/307469.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
CAD/CAM
protetyka stomatologiczna
DMLS
mikrostruktura
mikrotwardość
tytan
stop tytanu
CAD/CAM system
dental prosthetics
direct metal laser sintering
microstructure
microhardness
titanium
titanium alloy
Opis:
Purpose: The aim of the present paper was a question of structural identification and evaluation of strength parameters of Titanium (Ticp – grade 2) and its alloy (Ti6Al4V) which are used to serve as a base for those permanent prosthetic supplements which are later manufactured employing CAD/CAM systems. Methods: Microstructural tests of Ticp and Ti6Al4V were conducted using an optical microscope as well as a scanning microscope. Hardness was measured with the Vickers method. Micromechanical properties of samples: microhardness and Young’s modulus value, were measured with the Oliver and Pharr method. Results: Based on studies using optical microscopy it was observed that the Ticp from the milling technology had a single phase, granular microstructure. The Ti64 alloy had a two-phase, fine-grained microstructure with an acicular-lamellar character. The results of scanning tests show that titanium Ticp had a single phase structure. On its grain there was visible acicular martensite. The structure of the two phase Ti64 alloy consists of a β matrix as well as released α phase deposits in the shape of extended needles. Micromechanical tests demonstrated that the alloy of Ti64 in both methods showed twice as high the microhardness as Ticp. In studies of Young’s modulus of Ti64 alloy DMLS technology have lower value than titanium milling technology. Conclusions: According to the results obtained, the following conclusion has been drawn: when strength aspect is discussed, the DMLS method is a preferred one in manufacturing load structures in dentistry and may be an alternate way for the CAD/CAM system used in decrement processing.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 121-127
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biozgodność stopów protetycznych w funkcji czasu
Biocompatibility of prosthetic alloys as a function of time
Autorzy:
Hajduga, M.
Kalukin, B.
Kalukin, A.
Powiązania:
https://bibliotekanauki.pl/articles/99348.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
proteza dentystyczna
uzupełnienie protetyczne
stop protetyczny
implantacyjna stal austenityczna
biozgodność
prosthodontics
dental prosthesis
prosthetic restoration
prosthetic alloy
implantation austenitic steel
biocompatibility
Opis:
Od przeszło 3000 lat główną grupą materiałów, przeznaczonych do implantacji w organizmie ludzkim są metale i ich stopy. W ostatnim stuleciu najczęściej używana była i jest do dzisiaj implantacyjna stal austenityczna. W ostatnich 30 latach częściowo wyparły ją stopy niklu, kobaltu czy tytanu. Jedną z funkcji, mających wpływ na biozgodność materiału jest czas przebywania konstrukcji w agresywnym środowisku płynów ustrojowych. Autorzy podjęli próbę określenia zakresu zmian w materiałach metalicznych, po długotrwałej implantacji w jamie ustnej. Celem pracy jest określenie wpływu czasu użytkowania na zmianę właściwości materiałowych stopów stomatologicznych. W jej zakresie mieszczą się mikroskopowe badania metalograficzne, mikroanaliza rentgenowska oraz badania mikrotwardości. Wstępna analiza wyników potwierdza tak szerokie rozpowszechnienie implantacyjnej stali austenitycznej.
From 3000 years the majority of materials made for implantation in the human body are metals and alloys. In the last century the most commonly used was steel austenitic implantation. In the past 30 years, it was partly replaced by nickel alloys, cobalt alloys and titanium. One of the functions having the effect on biocompatibility of material is time of construction in aggressive environment, body fluids. The authors undertook an attempt to determine the extent of changes in the metallic materials after long-term implantation in the oral cavity. The aim of this work is to determine the effect of time for a change of using the material used in dental alloys. In this field there are metallographic microscopic examinations, X-ray microanalysis and micro hardness. Preliminary analysis of the results confirms such a wide spread of implantation austenitic steel.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 53-58
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena odporności korozyjnej stopu TI-6AL-4V po obróbce strumieniowo-ściernej stosowanym w protetyce stomatologicznej
Evaluation of corrosion resistance of Ti-6Al-4V alloys after blasting used in dental prosthetics
Autorzy:
Zapart, M.
Krawczyk, C.
Radwin, E.
Czerwik, M.
Sarraj, S.
Powiązania:
https://bibliotekanauki.pl/articles/99059.pdf
Data publikacji:
2018
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
stop Ti-6Al-4V
protetyka stomatologiczna
korozja wżerowa
korozja szczelinowa
kąt zwilżania
Ti-6Al-4V alloy
dental prosthetics
pitting corrosion
crevice corrosion
contact angle
Opis:
Niniejsza praca dotyczy badań odporności korozyjnej stopu Ti-6Al-4V o zmodyfikowanej powierzchni poprzez obróbkę mechaniczną (szlifowanie, polerowanie oraz obróbka strumieniowo-ścierna) do zastosowań w protetyce stomatologicznej. W ramach pracy przeprowadzono pomiar kąta zwilżania oraz badania odporności na korozje wżerową i szczelinową. Uzyskane wyniki jednoznacznie wykazały, że niezależnie od rodzaju modyfikacji powierzchni stop Ti-6Al-4V ma charakter hydrofilowy i jest odporny na korozję wżerową i szczelinową.
This work concerns tests of corrosion resistance of Ti-6Al-4V alloy with modified surface by mechanical treatment (grinding, polishing and abrasive blasting treatment) for applications in dental prosthetics. As part of the work, was measured the contact angle as well as the pitting and crevice corrosion resistance tests. Obtained results clearly showed that regardless of the type of surface modification, the Ti-6Al-4V alloy is hydrophilic and resistant to pitting and crevice corrosion.
Źródło:
Aktualne Problemy Biomechaniki; 2018, 16; 41-46
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania biomateriałów metalowych do komputerowego wspomagania projektowania i wytwarzania stałych konstrukcji protetycznych
Tests metallic biomaterials for computer-aided design and manufacturing of fixed prosthetic restorations
Autorzy:
Ryniewicz, A.
Bojko, Ł.
Ryniewicz, W.
Pałka, P.
Powiązania:
https://bibliotekanauki.pl/articles/197737.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
DMLS
mikrostruktura
mikrotwardość
moduł Younga
protetyka stomatologiczna
CAD/CAM
tytan
stop tytanu
direct metal laser sintering (DMLS)
microstructure
microhardness
Young's modulus
dental prosthetics
titanium
titanium alloy
Opis:
Laserowe spiekanie proszków metali (DMLS) jest nową technologią otrzymywania konstrukcji w procedurze CAD/CAM. Celem opracowania były identyfikacja strukturalna i wyznaczenie parametrów wytrzymałościowych tytanu oraz stopów tytanu przeznaczonych na podbudowy stałych uzupełnień protetycznych otrzymywanych przy komputerowym wspomaganiu projektowania i wytwarzania. Materiałem badań były próbki z czystego technicznie tytanu – gatunek 1 do wytworzenia konstrukcji w technologii obróbki frezowaniem oraz próbki Ti6Al4V z technologii laserowego, przyrostowego spiekania proszków. Wykonano badania mikrostrukturalne i mikromechaniczne. Na ich podstawie stwierdzono, że w aspekcie wytrzymałościowym DMLS jest technologią preferowaną do wykonawstwa stałych konstrukcji nośnych dla protetyki stomatologicznej i może stanowić alternatywę dla systemu CAD/CAM z obróbką ubytkową.
A direct metal laser sintering method (DMLS) is a new technology used for getting structures by the CAD/CAM procedures. The aim of the elaboration was a question of structural identification and setting strength parameters of titanium (Ticp) and its alloy (Ti6Al4V) which are used to serve as base for those permanent prosthetic supplements which are later manufactured with the employment of CAD/CAM systems. The research work was performed on Ticp samples – those which were intended for manufacture of structures by decrement milling working, and Ti6Al4V samples that comes from laser increment sintering of powder. According to the results obtained, the following conclusion has been derived: when strength aspect is discussed, the DMLS method is a preferred one for manufacturing of load structures in dentistry and may be an alternate way for the CAD/CAM system used in decrement processing.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2014, 82; 225-234
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Klasa przygotowania powierzchni prętów Ti6Al4V na jakość połączenia z ZrO2 w ocenie badań mikroskopowych
Class of surface treatment on the quality of the connection rods Ti6Al4V in the evaluation of microscopic examination
Autorzy:
Wita, K.
Czakon, K.
Hajduga, M.
Powiązania:
https://bibliotekanauki.pl/articles/99387.pdf
Data publikacji:
2015
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
kondycjonowanie powierzchni
cement dentystyczny
połączenie klejowe
stop tytanu
Ti6Al4V
dwutlenek cyrkonu
badania strukturalne
surface conditioning
dental cement
adhesive joint
titanium alloy
zirconium dioxide
structural research
Opis:
Celem pracy była ocena wpływu kondycjonowania piaskiem Al2O3 o gradacji: 50μm, 110μm, 250μm, powierzchni prętów Ti6Al4V na klasę połączenia z ZrO2 cementem dentystycznym RelyX 3M ESPE. Wnioski zostały formułowane na podstawie wyników badań topografii powierzchni 3D oraz oceny struktur metalograficznych.
The aim of the research was the impact assessment conditioning sand Al2O3 grit: 50μm, 110μm, 250μm, area bars Ti6Al4V on the class connection with ZrO2 dental cement RelyX 3M ESPE. Proposals where formulated based on research results of 3D surface topography and evaluating the structures metallographic.
Źródło:
Aktualne Problemy Biomechaniki; 2015, 9; 123-128
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-24 z 24

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies