Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "decreasing temperature" wg kryterium: Wszystkie pola


Wyświetlanie 1-3 z 3
Tytuł:
Influence of Bioaugmentation Strategy of Activated Sludge on the Co-Treatment of Reject Water and Municipal Wastewater at a Decreasing Temperature
Autorzy:
Szaja, Aleksandra
Szulżyk-Cieplak, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/125053.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
bioaugmentation
reject water
SBR
decreasing temperature
Archaea
Opis:
In the present study, the influence of bioaugmentation strategy on the co-treatment of 13% v/v reject water and municipal wastewater at a decreasing temperature was evaluated. The experiment was performed in two identical laboratory sequencing batch reactors with the active volume of 8 L. Each one was operated using a 12-hour cycle at sludge retention time of 3 d. The SBR A was bioaugmented with a mixture of wild-living bacteria and Archaea in a dose 0.25 ml. In turn, the comparative reactor (SBR B) was non-bioaugmented, the Archaea product was replaced with an equal volume of dechlorinated tap water. The experiment was divided into 3 phases, each with a different temperature range (20, 15 and 10°C). The temperature reduction did not adversely affect the process performance in the bioaugmented and non-bioaugmented system. Significant removal efficiencies were achieved in both SBRs. The major differences were observed for the COD content in the bioaugmented SBR at a temperature of 10°C. In this case, statistically lower concentrations in the effluent were observed in the bioaugmented system than in the non-bioaugmented one. Additionally, at a temperature of 10°C, an improved process performance was observed in the Archaea presence, but the differences were of no statistical significance.
Źródło:
Journal of Ecological Engineering; 2020, 21, 5; 97-106
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Critical Temperature Evaluation for a Steel Frame with Joint Stiffness Decreasing in Fire
Autorzy:
Maślak, M.
Pazdanowski, M.
Snela, M.
Powiązania:
https://bibliotekanauki.pl/articles/105154.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
steel bearing frame
fire
critical temperature
joint stiffness
moment-rotation relationship
weakest link
Opis:
A procedure to determine the critical temperature of a selected steel frame bearing structure is presented and discussed. This temperature, in case of fully developed fire, when the temperature of the exhaust gasses enveloping the structural members is equalized within the whole fire zone, may be considered as an impartial measure of safety. The obtained result does not depend on the heating progress but only on the static scheme and the load level in the considered structure. The quantitative and qualitative evaluation of the influence the joint stiffness decreasing in fire exerts on the resultant critical temperature constitutes the basic objective of the authors. It has been shown, that proceeding according to the recommended computational procedure does not necessarily result in an estimate fully unambiguous in interpretation. The critical temperature specified in a global mode, for the whole considered frame, is usually associated with a specific component of such frame, interpreted as the so called “weakest link”. Thus local loss of bearing capacity in such element is in this approach equivalent to the total destruction of the whole bearing structure. Indication, which of the components present in the considered frame should be treated as the critical one, because of its behaviour under fire conditions, seems to be a key to the forecast safety level warranted to the users of the structure. The authors show, that this association changes depending on the selected computational method, and this in turn substantially limits the reliability of the obtained estimate.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 91-101
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opredelenie temperatury samonagrevaniâ uglâ po sootnošeniû oksida ugleroda i ubyli kisloroda na avarijnom učastke
Identification of Temperature for Self Heating of Coal Caused by the Ratio of Carbon Oxide and Decreasing Oxygen Levels Along a Section Exposed to a Catastrophe
Określenie temperatury samonagrzewania się węgla w zależności od zawartości tlenku węgla i ubytku tlenu na odcinku awaryjnym
Autorzy:
Grekov, S. P.
Pashkovskiy, P. S.
Orlikova, V. P.
Powiązania:
https://bibliotekanauki.pl/articles/373904.pdf
Data publikacji:
2015
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
heterogeneous process
surface reaction segment
low temperature oxidation
reaction rate
activation energy
spontaneous combustion
proces heretogeniczny
udział/część powierzchni reakcyjnej
niskotemperaturowe utlenianie
szybkość reakcji
energia aktywacji
samonagrzewanie się
Opis:
Aim: The purpose of this study is to determine the temperature for self heating of coal, caused by the ratio of carbon monoxide and decreasing oxygen levels along a mining section exposed to a catastrophe. Introduction: The need for this study is associated with existing cumbersome methods used to determine the temperature of coal containing unsaturated hydrocarbons and necessity to identify a faster method for obtaining data about spontaneous fires, to facilitate the selection of appropriate firefighting measures. Methods: Methods are based on the theoretical model for non-isothermic kinetics of heterogeneous oxidation of coal with a variable reactionary oxygen surface, caused by the release of methane, as well as by formation and decay of surface compounds through oxygen adsorption and formation of stable particles. Results: A self heating model was put forward for a layer of coal, based on a representation involving a porous substance. It was assumed that a stream of filtered air, containing oxygen, oxidised upon entering such a layer and generated a heat source. Heat was absorbed across the coal surface culminating in an increase to its temperature. An analytical solution was obtained for this exercise. To describe the intensity of generated heat, the authors utilised their own, previously developed mathematical model. The model took into account the change in oxygen content and surface reaction, depending on coal oxidation levels. Some 30 experiments were performed and analysed, which addressed the issue of coal surface reaction and identified the relationship between the surface layer and degree of coal metamorphosis. This relationship was utilised to determine the proportion of oxygen absorbed during oxidation of coal. By taking account of such data it is possible to calculate the intensity of generated heat, its flow and temperature, and consequential use of oxygen during oxidation of coal. It is proposed that the ratio of carbon oxide to reduced oxygen levels along a section exposed to an emergency, as a result of oxidation can be used to determine coal temperature. This is illustrated by specific examples of mine incident analysis in the Donets Basin. Practical benefit: The identified dependences are recommended for further research and industrial application with the aim of controlling the temperature of self heating coal. Conclusions: The mathematical model for surface self heating of coal and porous substances, was approved during tests at NIIGD “Respirator” (Ukraine) and the Federal Republic of Germany, within the temperature range of 340–400 K, for use with different coal quality. It is proposed that the ratio of carbon oxide to oxygen used for oxidation reactions is utilized to determine the temperature of coal. Demonstrated full compatibility between derived results for temperature calculations and data concerning the ratio of ethylene to acetylene.
Cel: Celem badań jest określenie temperatury samonagrzewania się węgla w zależności od zawartości tlenku węgla i ubytku tlenu na odcinku awaryjnym. Aktualność badań: Potrzeba przeprowadzenia badań wiąże się z czasochłonnością wykorzystywanej dotychczas metody określenia temperatury węgla ze względu na zawartość węglowodorów nienasyconych oraz koniecznością opracowania szybkiej metody pozyskiwania danych na temat pożaru endogennego, które są niezbędne podczas wyboru odpowiednich środków do jego ugaszenia. Metody: Metody opierały się na teoretycznym modelu nieizotermicznej kinetyki heterogenicznego utleniania tlenem z powietrza węgli ze zmienną (niejednorodną) powierzchnią reakcyjną, co powodowane jest wydzielaniem metanu z węgla, a także powstawaniem i rozpadem związków powierzchniowych przy adsorpcji tlenu i powstawaniu przy powierzchni stałych produktów reakcji. Wyniki: W artykule zaproponowany został model procesu samonagrzewania się warstwy węgla na przykładzie środowiska porowatego. Założono, że wchodzący do takiej warstwy strumień filtrowanego powietrza wstępuje w reakcje chemiczne utleniania, przez co generowane jest źródło ciepła. Wydzielające się ciepło jest wydatkowane na przejście przez powierzchnię warstwy węgla i zwiększenie jego temperatury. Otrzymano rozwiązanie analityczne tego zadania. Do opisania intensywności wydzielania ciepła wykorzystano wcześniej opracowany przez autorów model matematyczny. Uwzględniono w nim zmianę zawartości tlenu i powierzchni reakcyjnej w miarę utleniania się węgla. Przeanalizowano około 30 eksperymentów polegających na określeniu powierzchni reakcyjnej węgla i otrzymano zależność między nią a stopniem metamorfizmu węgla. Zaproponowano wykorzystanie tej zależności do określenia zawartości procentowej tlenu wstępującego w reakcję utleniania węgla. Z uwzględnieniem tych danych możliwe jest wyliczenie: intensywności wydzielania ciepła, jego spadku i temperatury oraz zależności między zużyciem tlenu a utlenianiem się węgla. Autorzy przedstawili zależność, na podstawie której możliwe jest obliczenie temperatury węgla pod względem zawartości tlenku węgla i ubytku tlenu na odcinku awaryjnym. Na rzeczywistych przykładach awarii w kopalniach w Donbasie przedstawiono możliwość określenia temperatury samonagrzewania się węgla na podstawie danych analizy powietrza na odcinku awaryjnym. Znaczenie dla praktyki: Otrzymane zależności są rekomendowane do badań i zastosowań przemysłowych w celu kontroli temperatury samonagrzewania się węgla. Wnioski: Zaproponowany model matematyczny samonagrzewania się w warstwie węgla – środowisku porowatym – potwierdzony został w drodze eksperymentów przeprowadzonych przez Instytut Naukowo-Badawczy Górnictwa „Respirator” (Ukraina) i Republikę Federalną Niemiec w granicy temperatur 340–400 K na węglach o różnym stopniu uwęglenia. W celu określenia temperatury węgla zaproponowano wykorzystanie modelu opisującego stosunek zawartości tlenku węgla i tlenu biorącego udział w reakcjach utleniania. Wykazano pełną zgodność otrzymanych wyników wyliczeń temperatury z danymi w odniesieniu do etylenu i acetylenu.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2015, 3; 119-127
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies