Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "correction" wg kryterium: Wszystkie pola


Tytuł:
Correction of the refraction phenomenon in photogrammetric measurement systems
Autorzy:
Samper, D.
Santolaria, J.
Majarena, A. C.
Aguilar, J. J.
Powiązania:
https://bibliotekanauki.pl/articles/221366.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
refraction correction
photogrammetry
correction polynomials
Opis:
This paper presents a method of correcting the effects caused by refraction phenomena in an optical measurement system. The correction algorithm proposed can be applied in many different photogrammetric applications affected by these effects. To validate this algorithm, a foot sole optical measurement system that uses several cameras to build a mesh of a foot sole has been used. This measurement system has six cameras that are protected by a safety glass that separates the cameras from the foot to be measured. The safety glass produces an air-glass-air interface that causes the refraction phenomena, producing deformations in the images. Due to the deformations it is impossible to obtain reliable metric information of the images captured using the measurement system. The developed correction algorithm is based on a grid layout and associated polynomials and makes it possible to correct the deformations and extract accurate metric information.
Źródło:
Metrology and Measurement Systems; 2013, 20, 4; 601-612
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evolution of the lower Mszanka Channel section after training using stage correction method
Autorzy:
Korpak, J.
Powiązania:
https://bibliotekanauki.pl/articles/62402.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
evolution
Mszanka Channel
stage correction
correction method
mountain stream
stream training
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2015, IV/3
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Korekta
Correction
Autorzy:
Sitkiewicz, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/645899.pdf
Data publikacji:
2014-03-03
Wydawca:
Fundacja Terytoria Książki
Opis:
The fourth issue of “Schulz/Forum” is an opportunity to draw conclusions, but also to correct the originally chosen approach. Its dominant are Jewish motifs in Schulz’s life and fiction. Besides, it contains a new rubric, “Horizon of Reading.” The future numbers will focus not so much on Schulz himself, but on various problems related to his oeuvre. We are planning to publish special thematic issues on Schulz’s women, his literary and artistic followers, the literature of Galicia, masochism, and Schulz’s manuscripts. Besides, “Schulz/Forum Library” and an annotated edition of Schulz’s complete writings and drawings will be initiated this year, too. Therefore, interpretations, analyses, reviews, and archival materials related to the above are welcome.
Źródło:
Schulz/Forum; 2014, 4; 3-4
2300-5823
Pojawia się w:
Schulz/Forum
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Znaczenie korekcji radiometrycznej w procesie przetwarzania zdjęć satelitarnych
The importance of radiometric correction in satellite images processing
Autorzy:
Osińska-Skotak, K.
Powiązania:
https://bibliotekanauki.pl/articles/129866.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
korekcja radiometryczna
korekcja atmosferyczna
radiometric correction
atmospheric correction
Opis:
Korekcja radiometryczna jest wstępnym etapem przetwarzania danych satelitarnych, który ma na celu usuniecie błędów radiometrycznych oraz przede wszystkim przetworzenie obrazu satelitarnego na jednostki radiancji spektralnej, pochodzącej od powierzchni Ziemi lub odbicia spektralnego. Niestety ale w praktyce korekcja radiometryczna obrazów wielospektralnych rzadko kiedy wykonywana jest w pełnym zakresie. Wynika to z kilku różnych przyczyn o charakterze technicznym ale także historycznym, związanych z początkami powstawania technologii przetwarzania danych satelitarnych. I to właśnie te historyczne uwarunkowania wpłynęły na fakt, i_ pełen proces korekcji radiometrycznej rzadko jest stosowany przy przetwarzaniu danych wielospektralnych. A przecie_ wykonanie korekcji radiometrycznej lub jej zaniechanie ma wpływ praktycznie na każdy rodzaj dalszego przetwarzania danych satelitarnych. Artykuł przedstawia idee korekcji radiometrycznej, omawia jej etapy oraz prezentuje przykłady wpływu korekcji radiometrycznej na efekty różnych podstawowych, najczęściej wykonywanych przetworzeń obrazów satelitarnych.
The radiometric correction is and initial stage in satellite data processing, intended to remove radiometric errors and, primarily, to convert the satellite image to a unit of spectral radiance from Earth surface or spectral reflection. However, in practice the radiometric correction of multispectral images is unfortunately rarely performed in the full scope. This is due to various reasons of technical and also historical nature, related to the very beginning of the satellite data processing technologies. It is such historical aspects that have caused the complete radiometric correction process to be rarely performed while processing multi-spectral data. Yet, the performance or failure to perform the radiometric correction affects virtually all further processing of satellite data. The present paper gives an overview of the radiometric correction, describes its stages and presents examples of the effects of radiometric correction on the results of various basic, most frequent processing of satellite images.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2007, 17b; 577-590
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A corrected correction
Autorzy:
Isbell, J.
Powiązania:
https://bibliotekanauki.pl/articles/1377703.pdf
Data publikacji:
1971
Wydawca:
Polska Akademia Nauk. Instytut Matematyczny PAN
Źródło:
Fundamenta Mathematicae; 1971, 71, 2; 185
0016-2736
Pojawia się w:
Fundamenta Mathematicae
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Critical Remarks on Roman Law in the Prussian Correction
Autorzy:
Lisowski, Zygmunt
Powiązania:
https://bibliotekanauki.pl/articles/1832028.pdf
Data publikacji:
2019-09-15
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
history of law
roman law
prussian correction
Opis:
The paper is an English translation of O prawie rzymskim w korekturze pruskiej. Uwagi krytyczne by Zygmunt Lisowski, published originally in Polish in “Czasopismo Prawno–Historyczne” in 1954. The text is pub-lished as a part of a jubilee edition of the “Adam Mickiewicz University Law Review. 100th Anniversary of the Faculty of Law and Administra-tion” devoted to the achievements of the late Professors of the Faculty of Law and Administration of the Adam Mickiewicz University, Poznań.
Źródło:
Adam Mickiewicz University Law Review; 2019, 10; 131-165
2450-0976
Pojawia się w:
Adam Mickiewicz University Law Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt aparatu do korekcji przodozgryzu
Anteroclusion correction apparatus
Autorzy:
Wróbel, E.
Sajewicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/98696.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
przodozgryz
korekcja
aparat
anteroclusion
correction
apparatus
Opis:
Celem niniejszego artykułu jest przedstawienie nowego typu aparatu do korekcji przodozgryzu. Urządzenie jest oparte na budowie klasycznej procy bródkowej. Tekst zawiera opis budowy, zasadę działania, jak i analizę zaprojektowanego urządzenia. Aby podkreślić innowacyjność urządzenia, zaprezentowano istniejące już metody korekcji prognatyzmu oraz założenia, którymi się kierowano podczas projektowania.
The purpose of this article is to present a new type of the anteroclusion correction apparatus. This apparatusis is based on a classical chin cap. Text contains description of structure, principle of operation and analysis of this project. The article presents existing apparatus and assumption correction methods, which were helpful during projecting process. In addition it shows the project's innovation.
Źródło:
Aktualne Problemy Biomechaniki; 2014, 8; 173-180
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compound Channel’s Cross-section Shape Effects on the Kinetic Energy and Momentum Correction Coefficients
Autorzy:
Ghanbari-Adivi, Elham
Powiązania:
https://bibliotekanauki.pl/articles/1837762.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
CES model
compound channel
FCF
floodplain
kinetic energy correction coefficient
momentum correction coefficient
Opis:
Since accurate estimation of the flow kinetic energy (α) and momentum (β) is not easily possible in compound channels, determining their accurate correction coefficients is an important task. This paper has used the “flood channel facility (FCF)” data and the “conveyance estimate system (CES)” model (which is 1D, but considers a term related to the secondary flow) to study how the floodplain width and the main channel wall slope and asymmetry affect the values of α and β. Results have shown that their maximum values at the highest floodplain width are, respectively, 1.36 and 1.13 times of those at the lowest case; an increase in the slope increased their maximum values by 1.05 and 1.01 times, respectively. The mean of error values showed that the CES model estimated the values α and β more accurately than the flow discharge. The maximum differences between the estimated and experimental values were 12.14% for α and 4.3% for β; for the flow discharge, it was 24.4%.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2020, 67, 1-4; 55-71
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A high pressure resonator transducer with programmed correction of static characteristics
Autorzy:
Tomczuk, K.
Powiązania:
https://bibliotekanauki.pl/articles/220854.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pressure transducer
quartz resonator
algorithmic correction
Opis:
A high pressure resonator transducer (0 to 100 MPa) devised by the author has been described. The elastic element of the converter consists of a cylinder with an offset arranged axis hole. Quartz resonators were used for the measurement of deformations of the pipe. Based upon the results of the transducer testing, a new algorithmic method for the minimizalizsation of the temperature error, that eliminates the need for a temperature gauge has been worked out.
Źródło:
Metrology and Measurement Systems; 2013, 20, 4; 667-677
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Self-absorption correction in gamma-ray spectrometry of environmental samples - an overview of methods and correction values obtained for the selected geometries
Autorzy:
Jodłowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/148531.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
gamma-ray spectrometry
self-attenuation
self-absorption
correction factor
Opis:
Of major concern are the self-absorption correction factors Cs in precise gamma-ray spectrometry of environmental samples. The overview of Cs determination methods (experimental, Monte Carlo calculations, analytical function application) is presented. Among several available methods, the author chose the one proposed by Debertin where the uncertainty level of Cs correction factor is 1÷2%. The point-like detector model is assumed whilst its efficiency is taken to be proportional to the weighted sum (integral) of the number of photons coming from sample volume elements. Computer program was developed to support the computation of Cs by the Debertin's method for samples in cylindrical geometries and Marinelli beakers. The input data are sample dimensions, density and the mass attenuation coefficient. The Cs uncertainty due to an arbitrarily chosen position of a point-like detector would not exceed 1% for the considered photon energies and the sample density range. Utilising this computer program, the relationships Cs(E,ń) were obtained for the applied geometries and a SiO2 matrix to support routine measurements. The SiO2 matrix is widely encountered in environmental spectrometry. This relationship was derived by fitting the computed data with the function Cs(E,ń) in the form proposed by Bolivar. It was shown that while handling this function to samples with the H2O matrix, the error involved in estimations would not exceed 3%.
Źródło:
Nukleonika; 2006, 51,suppl.2; 21-25
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic Error Correction of Methane Sensor
Autorzy:
Krupanek, B.
Bogacz, R.
Powiązania:
https://bibliotekanauki.pl/articles/227009.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dynamic error correction
methane sensor
pellistor sensor
safety in mine
Opis:
Coal mine methane is a term given to the methane gas produced or emitted in association with coal mining activities either from the coal seam itself or from other gassy formations underground. The primary reason for measuring methane is to improve the safety of the mines. In recent years, there have been many fatalities in underground coal mine explosions in which methane was a contributing factor. The rapid detection of methane is very important from the point of view of safety of mine workers. This paper presents a concept of fast methane detection by reconstituting its concentration in dynamic states.
Źródło:
International Journal of Electronics and Telecommunications; 2014, 60, 4; 287-289
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Can Indirect, Delayed Error Correction Improve Students’ Willingness to Speak in the Target Language?
Autorzy:
Pham, Quang Nam
Powiązania:
https://bibliotekanauki.pl/articles/888727.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Warszawski. Wydawnictwa Uniwersytetu Warszawskiego
Tematy:
teaching
correction
SLT
speaking
Opis:
At a high school where I have worked as a visiting lecturer, students of English as a Foreign Language (EFL) tend to use their mother tongue (L1) instead of the target language (L2) in communicative activities. Many factors are to blame for this issue, such as the seating arrangement, the language curriculum, the influences from the interlocutors, and the teacher correction methods (Pham 2005). This study aims to propose a strategy to correct student errors during communicative activities. Data analysis shows that the strategy of error correction that a teacher uses will have a substantial impact on student use of L2 in oral activities. Drawing from such fi ndings, I suggest some practical teaching strategies to maximize L2 and minimize L1 in speaking activities.
Źródło:
Anglica. An International Journal of English Studies; 2018, 27/2; 173-189
0860-5734
Pojawia się w:
Anglica. An International Journal of English Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A sharp correction theorem
Autorzy:
V. Kisliakov, S.
Powiązania:
https://bibliotekanauki.pl/articles/1289654.pdf
Data publikacji:
1995
Wydawca:
Polska Akademia Nauk. Instytut Matematyczny PAN
Opis:
Under certain conditions on a function space X, it is proved that for every $L^∞$-function f with $∥f∥_{∞} ≤ 1$ one can find a function φ, 0 ≤ φ ≤ 1, such that φf ∈ X, $mes{φ ≠ 1} ≤ ɛ∥f∥_1$ and $∥φf∥_X ≤ const(1 + log ɛ^{-1})$. For X one can take, e.g., the space of functions with uniformly bounded Fourier sums, or the space of $L^∞$-functions on $ℝ^n$ whose convolutions with a fixed finite collection of Calderón-Zygmund kernels are also bounded.
Źródło:
Studia Mathematica; 1995, 113, 2; 177-196
0039-3223
Pojawia się w:
Studia Mathematica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Correction of gas sensor dynamic errors by means of neural networks
Autorzy:
Roj, J.
Urzędniczok, H.
Powiązania:
https://bibliotekanauki.pl/articles/114150.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
gas sensors
artificial neural networks
dynamic correction
Opis:
The paper presents a method based on artificial neural network (ANN) technique applied for correction of dynamic error of gas concentration measuring transducer. Its response time is about 8 minutes. The results obtained in the research of this transducer were used for learning and testing ANN, which were implemented in the dynamic correction task. The described method allowed for significant reduction of the transducer’s response time – the output signal was practically fixed after a time equal to one sampling period of output signal provided that the stimulus is a step function. In addition, the use of ANN allows reducing the impact of the transducer dynamic non-linearity on the correction effectiveness.
Źródło:
Measurement Automation Monitoring; 2015, 61, 12; 538-541
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Geometric correction of APEX hyperspectral data
Autorzy:
Vreys, Kristin
Iordache, Marian-Daniel
Biesemans, Jan
Meuleman, Koen
Powiązania:
https://bibliotekanauki.pl/articles/1035951.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Warszawski. Wydział Geografii i Studiów Regionalnych
Tematy:
Hyperspectral
APEX
Geometric correction
Airborne
Georeferencing
Boresight calibration
Opis:
Hyperspectral imagery originating from airborne sensors is nowadays widely used for the detailed characterization of land surface. The correct mapping of the pixel positions to ground locations largely contributes to the success of the applications. Accurate geometric correction, also referred to as “orthorectification”, is thus an important prerequisite which must be performed prior to using airborne imagery for evaluations like change detection, or mapping or overlaying the imagery with existing data sets or maps. A so-called “ortho-image” provides an accurate representation of the earth’s surface, having been adjusted for lens distortions, camera tilt and topographic relief. In this paper, we describe the different steps in the geometric correction process of APEX hyperspectral data, as applied in the Central Data Processing Center (CDPC) at the Flemish Institute for Technological Research (VITO, Mol, Belgium). APEX ortho-images are generated through direct georeferencing of the raw images, thereby making use of sensor interior and exterior orientation data, boresight calibration data and elevation data. They can be referenced to any userspecified output projection system and can be resampled to any output pixel size.
Źródło:
Miscellanea Geographica. Regional Studies on Development; 2016, 20, 1; 11-15
0867-6046
2084-6118
Pojawia się w:
Miscellanea Geographica. Regional Studies on Development
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies