Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cooling efficiency" wg kryterium: Wszystkie pola


Tytuł:
Experimental Study of Temperature Influence on the Performance of PV/T Cell under Jordan Climate Conditions
Autorzy:
Al-Odat, Mohammed Qassim
Powiązania:
https://bibliotekanauki.pl/articles/2202185.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PV module
electrical conversion
electrical efficiency
water cooling
cooling
cell temperature
Opis:
The electrical performance and the productivity of PV module depend on two main parameters, i.e. the radiation intensity and the cell operating temperature. The module electrical efficiency and productivity are significantly reduced as its temperature increases. Accordingly, cooling of PV modules is one of the most effective techniques to obtain higher efficiency and productivity as well as to reduce the degradation modes of PV modules due to high temperatures. This research work presents an experimental study carried out to investigate the effect of PV module cooling on the performance of PV module under Irbid city (Jordan) climate conditions. It was found that the electrical efficiency and the productivity of the PV modules were approximately enhanced by 14%. Therefore, water cooling of the PV modules is essential to enhance their performance.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 80--88
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing of Air-Cooling Efficiency of the Underside of a Turning Tool Carbide Insert in EN-GJL 250 Cast Iron Turning Operations
Autorzy:
Bartoszuk, Marian
Prażmowski, Mariusz
Hurey, Igor
Powiązania:
https://bibliotekanauki.pl/articles/2201829.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
cast-iron machining
air cooling systems
cutting temperature
surface roughness
tool wear
Opis:
This article shows the results of research on the effectiveness of operation of an original tool air cooling system in cutting. A case of turning EN-GJL 250 cast iron with TH10 tungsten carbide cutting inserts without protective coatings was selected for testing. The paper gives constructional details of the tested tool cooling system and discusses the principle of its operation. The research carried out has shown that this way of cooling the cutting insert causes a significant decrease in temperature in all sub-areas of the cutting zone. In addition, air cooling has been proven to significantly reduce cutting tool wear and slightly improve the roughness of the machined surface. The results obtained showed that the proposed method of cooling can be successfully used in the treatment of grey cast iron. In the future, it may serve as a basis for the construction of a professional cooling system for industrial applications.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 4; 1--9
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczenia efektywności chłodzenia silnika elektrycznego
Calculation of cooling efficiency of the electric motor
Autorzy:
Będkowski, B.
Madej, J.
Powiązania:
https://bibliotekanauki.pl/articles/1201904.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
MES
CFD
obliczenia cieplne
chłodzenie powietrzne
wydajność wentylatora
FEM
thermal calculations
air cooling
fan efficiency
Opis:
The preparation of a calibrated numerical model of the electric motor and the effectiveness of the air cooling system are presented in the article. The bench, consisting of a complete motor case and the stator, and the shaft with a fan mounted on its end was used to the model calibration. The volume flow rate of the fan with air velocity at selected points around the motor case, and the temperature at the selected measuring points in the device thermal steady state were measured. The calorimetric method and thermoanemometr were used to measure volume flow rate of the fan. The performance of the air cooling system for different values of losses (150W, 350W, 550W) at a constant fan speed (900 rpm) and for constant power (550W) at different fan speeds (300 rpm, 600 rpm, 900 rpm) was carried out. The discrete models for fan volume flow rate and the heat-flow calculations were prepared separately to determine the temperature of selected points of the cooling system. The set of characteristics showing the effects of rotational speed of the fan to the temperature of selected elements of the system was prepared on the basis of the tests and calculations.
Praca dotyczy opisu budowy skalibrowanego modelu obliczeniowego silnika elektrycznego i prezentuje efektywność chłodzenia urządzenia przy zastosowaniu powietrznego układu chłodzenia. Badania kalibracyjne zostały przeprowadzone na stanowisku, składającym się z kompletnego kadłuba wraz ze stojanem i wałem z wentylatorem osadzonym na jego końcu. W wyniku przeprowadzonych badań zmierzono wydatek wentylatora zamontowanego w układzie chłodzącym oraz prędkość powietrza w wybranych punktach wokół kadłuba, a następnie przeprowadzono próby nagrzewania i rejestracji temperatury w wybranych punktach pomiarowych. Pomiar wydatku wentylatora przeprowadzono metodą kalorymetryczną oraz przy pomocy termoanemometru. Pomiary wydajności powietrznego układu chłodzenia przeprowadzono dla różnych wartości strat (150W, 350W, 550W) przy stałej prędkości obrotowej wentylatora (900 obr/min) oraz dla stałej mocy (550W) przy różnych prędkościach wentylatora (300 obr/min, 600 obr/min, 900 obr/min). Obliczenia przeprowadzono budując osobno modele dyskretne do wyznaczenia wydatku wentylatora i do obliczeń cieplno-przepływowychw celu określenia temperatury w wybranych punktach układu. Przeprowadzone badania i obliczenia pozwoliły opracować zestaw charakterystyk przedstawiających wpływ prędkości obrotowej wentylatora na temperaturę wybranych elementów układu.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 2, 110; 15-20
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczanie wydajności układu chłodzenia ON-AN transformatora energetycznego średniej mocy
Calculation of efficiency of ON-AN cooling system on mid power transformer
Autorzy:
Bródka, B.
Sapała, J.
Łopatkiewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/376965.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transformator
radiator
układ chłodzenia ON-AN
Opis:
W artykule zawarto wyniki wstępnych prac, mających na celu opracowanie narzędzia obliczeniowego służącego do wyznaczania wydajności układu chłodzenia transformatora energetycznego średniej mocy. Do rozważań przyjęto transformatory o naturalnym obiegu oleju i naturalnym obiegu powietrza (ON-AN). Jako przykładową jednostkę obrano transformator o mocy 10 MVA (110/15 kV) produkcji firmy Power Engineering w Czerwonaku. Wyniki obliczeń porównano z wynikami próby nagrzewania transformatora, podczas zwarcia pomiarowego, wykonanej w fabryce. Ze względu na skomplikowany kształt elementów konstrukcyjnych transformatora (kadź, radiatory, część aktywna), narzędzie obliczeniowe wykorzystuje geometrię w przestrzeni. Wymiary wszystkich elementów otrzymano od producenta transformatora. Geometrię transformatora odpowiednio uproszczono w celu ograniczenia złożoności obliczeń. Obliczenia wykonano przy użyciu oprogramowania COMSOL Multiphysics. Opracowane narzędzie obliczeniowe obejmuje jedynie zjawisko konwekcji i przejmowania ciepła z uzwojeń do oleju a następnie z oleju do ścianek kadzi i radiatorów. Ze względu na dużą zbieżność wyników obliczeń z wynikami próby nagrzewania, narzędzie obliczeniowe będzie rozwijane i poprawiane w przyszłości. W publikacji zawarte zostały dalsze kierunki prac.
Results of preliminary calculation efficiency of ON-AN transformer cooling system are shown in the article. The results are shown for transformer 10 MVA. The transformer was produced in Power Engineering in Czerwonak. The results was compared with results of temperature-rise type test made in factory. Calculation was made as 3D model. All geometrical parameters was obtained from manufacturer of transformer. Geometry of transformer was simplified to made calculation less complex. Software COMSOL Multiphysics was used for the calculation. Convection and heat transfer from windings to oil and from oil to walls of radiators was only used in this calculations. In view of large convergence of calculation results and temperature-rise type test results the calculation tool will revise and expand.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 82; 227-233
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Window Roller Blinds on Energy Consumption in Residential Buildings in Serbia
Autorzy:
Djoković, Jelena M.
Nikolić, Ružica R.
Bokůvka, Otakar
Pastorková, Jana
Powiązania:
https://bibliotekanauki.pl/articles/27323565.pdf
Data publikacji:
2023
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
exterior window blinds
heat load
cooling load
lighting
energy efficiency
rolety zewnętrzne
obciążenie cieplne
obciążenie chłodnicze
oświetlenie
efektywność energetyczna
Opis:
Roller blinds are devices that are retracted and wrapped in a box above the window opening and are used to protect against the solar radiation. Those are the well-known devices with distinct advantages over the fixed external dimming elements. The influence of external blinds on the internal thermal environment in climatic conditions in the Republic of Serbia, the city of Kragujevac, was considered in this research. An external blind was installed in the test room and its influence on the internal temperature was compared with the internal temperature of the room without the blind. Real-time monitoring was carried out in February and August 2023. The results presented in this paper show that the blind reduces the temperature in summer by 3.57ºC and increases it in winter by 1.76ºC. The cooling load can be reduced by about 20%, and the heat load by about 15%.
Źródło:
System Safety : Human - Technical Facility - Environment; 2023, 5, 1; 75-82
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cooling water flow influence on power plant unit performance for various condenser configurations setup
Autorzy:
Dobkiewicz-Wieczorek, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/2091367.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling water
power plant efficiency
cooling water flow control
CHP plant
efficiency
Opis:
This paper presents the influence of cooling water regulation on power plant net efficiency. It was examined whether, for the non-nominal low-pressure turbine load, it is justified to reduce the cooling water pump load, and how it would affect the unit net efficiency. Calculations for two types of power units were carried out: with condensing and extraction-condensing turbine. The tested condensing power plant consists of three surface condensers. The calculation included four condensers’ connections set up on the cooling water side to check how the cooling water system pressure drop affects the net unit performance. The result has confirmed that implementing serial connection decreases net efficiency when cooling water flow regulation is used, but the mixed connection should be applied when pump load is not controlled. It was proved that the cooling water flow control gives a profit for both units. Net efficiency for combined heat and power plant can be improved by 0.1–0.5 pp, the gain is remarkable below 60% of the low-pressure turbine part load. Flow control implementation in the unit with condensing turbine water control gives a similar profit just below 80% of the turbine load. Next, an influence of the additional limitations of a cooling water system (minimal total pump head, cooling tower) affecting the feasibility of implementing the water control has been considered. Applying a multi-cell forced draft cooling tower does not have a significant impact on results, but when a natural draft cooling tower is used, the flow control range is strongly reduced.
Źródło:
Archives of Thermodynamics; 2022, 43, 1; 141--167
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of efficiency of the cooling system on the thermodynamic parameters and performance of a two - stage VC 20.96 reciprocating compressor designed to serve as a marine engine starter
Autorzy:
Grzelczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/259561.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
reciprocating compressor
liquid-cooled compressor
efficiency
polytropic exponent
Opis:
The paper presents results of the research related to the analysis of the thermodynamic and flow processes occurring in a prototype VC 20.96 two-stage liquid-cooled reciprocating compressor. The compressor has been developed and manufactured by H. Cegielski Poznan metal works in collaboration with the Poznan University of Technology. The research related to the VC compressor was realized within the KBN 3127/C.T07-6/2002 project titled “Development of design of type-series of reciprocating compressors and their implementation in production”. The basic task of the project was to develop two type-series of liquid- and air- cooled reciprocating compressors of the V- and W- arrangement, designed to serve as marine engine starters. The result of the design work was the manufacturing of two compressors: the VC 20.96 liquid-cooled compressor and the WP 18.80 air-cooled one. The main aim of the research described in this paper was to evaluate the efficiency of the cooling system which uses inter-coolers integrated with the compressing stages and the cooperation of the compressing stages in terms of pressure ratio distribution. Owing to the cooling method, the applied design assumptions enabled to develop a compact compressor fulfilling the assumed operating parameters.
Źródło:
Polish Maritime Research; 2013, 4; 25-33
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ground and in-fligh testing of cooling efficiency of turboprop engine compartment
Badania na ziemi i w locie skuteczności chłodzenia przedziału silnika turbośmigłowego
Autorzy:
Idzikowski, M.
Miksa, W.
Powiązania:
https://bibliotekanauki.pl/articles/213173.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
light aircraft
in-flight tests
turboprop engine installation
turboprop engine integration in airframe
engine compartment cooling
samolot lekki
badania w locie
zabudowa silnika turbośmigłowego
integracja silnika turbośmigłowego z płatowcem
chłodzenie przedziału silnika
Opis:
This article presents selected results of I-31T propulsion tests, obtained in the framework of EU project ESPOSA (Efficient Systems and Propulsion for Small Aircraft). I-31T aircraft, as a testbed, was fitted with 180 kW turboprop engine TP100. The scope of the work include results of ground and in-flight tests of engine compartment cooling suitability. The purpose of the cooling tests was to prove that temperatures of the propulsion components are within limits set by the engine manufacturer for the engine type in the most disadvantageous conditions on the ground and in flight up to aircraft maximum altitude, maximum ambient temperature and after standard engine shutdown. Engine oil cooling is beyond the scope of this work.
Praca zawiera wybrane wyniki badań w locie zespołu napędowego samolotu I-31T, które uzyskano podczas realizacji europejskiego projektu badawczego ESPOSA (Efficient Systems and Propulsion for Small Aircraft). Samolot I-31T jako platforma badawcza był wyposażony w silnik turbośmigłowy typu TP100 o mocy startowej 180 kW. W pracy przedstawiono wyniki prób na ziemi i w locie przeprowadzone pod kątem sprawdzenia prawidłowości chłodzenia przedziału silnika. Prezentowane badania prezentują przeprowadzone próby chłodzenia aby dowieść, że temperatury elementów zespołu napędowego utrzymywane są w zakresie ograniczeń, ustalonych dla tych elementów przez producenta silnika, w najbardziej niekorzystnych warunkach użytkowania na ziemi i w locie do maksymalnej wysokości lotu i w warunkach maksymalnej temperatury otaczającej atmosfery oraz po normalnym wyłączeniu silnika. Praca nie porusza tematu chłodzenia oleju silnika. Słowa kluczowe: samolot lekki, badania w locie, zabudowa silnika turbośmigłowego, integracja silnika turbośmigłowego z płatowcem, chłodzenie przedziału silnika.
Źródło:
Prace Instytutu Lotnictwa; 2018, 1 (250); 16-24
0509-6669
2300-5408
Pojawia się w:
Prace Instytutu Lotnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of the impact of construction solutions on operating parameters of the internal heat exchanger with refrigerant R744
Autorzy:
Janus, Jakub
Skotniczy, Przemysław Jan
Richert, Maria
Powiązania:
https://bibliotekanauki.pl/articles/240370.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat exchanger
internal heat exchanger
cooling efficiency
numerical fluid mechanics
wymiennik ciepła
wewnętrzny wymiennik ciepła
efektywność chłodzenia
numeryczna mechanika płynów
Opis:
Work on increasing the efficiency of heat exchangers used in car air conditioning systems may lead to a partial change in the construction of refrigeration systems. One of such changes is the use of smaller gas coolers, which directly translates into a reduction in the production costs of the entire system. The article presents the use of computational fluid dynamics methods to simulate the impact of changing the shape of an internal heat exchanger on the cooling efficiency with R744 as the refrigerant. Internal heat exchangers with different geometry of the outer channels were subjected to numerical analysis. The obtained results of calculations show temperature changes in inner and outer channels on the length of the heat exchanger.
Źródło:
Archives of Thermodynamics; 2019, 40, 1; 145-160
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of cooling lubricants on the surface roughness and energy efficiency of the cutting machine tools
Autorzy:
Jersák, J.
Simon, S.
Powiązania:
https://bibliotekanauki.pl/articles/265834.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
machining
turning
milling
process fluids
minimum quantity lubrication
chropowatość powierzchni
smar chłodzący
narzędzia skrawające
obróbka skrawaniem
Opis:
The Technical University of Liberec and Brandenburg University of Technology Cottbus-Senftenberg investigated the influence of cooling lubricants on the surface roughness and energy efficiency of cutting machine tools. After summarizing the achieved experimental results, the authors conclude that cooling lubricants extensively influence the cutting temperature, cutting forces and energy consumption. Also, it is recognizable that cooling lubricants affect the cutting tools lifetime and the workpiece surface quality as well. Furthermore, costs of these cooling lubricants and the related environmental burden need to be considered. A current trend is to reduce the amount of lubricants that are used, e.g., when the Minimum Quantity Lubrication (MQL) technique is applied. The lubricant or process liquid is thereby transported by the compressed air in the form of an aerosol to the contact area between the tool and workpiece. The cutting process was monitored during testing by the three following techniques: lubricant-free cutting, cutting with the use of a lubricant with the MQL technique, and only utilizing finish-turning and finish-face milling. The research allowed the authors to monitor the cutting power and mark the achieved surface quality in relation to the electrical power consumption of the cutting machine. In conclusions, the coherence between energy efficiency of the cutting machine and the workpiece surface quality regarding the used cooling lubricant is described.
Źródło:
International Journal of Applied Mechanics and Engineering; 2017, 22, 3; 779-787
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enhancement of the Brayton cycle efficiency by water or steam utilization
Autorzy:
Jesionek, K.
Chrzczonowski, A.
Ziółkowski, P.
Badur, J.
Powiązania:
https://bibliotekanauki.pl/articles/175275.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Brayton cycle
regeneration
Cheng cycle
thermodynamic analysis
gas steam turbine
computational flow mechanics
steam injection
water injection
interstage cooling
Opis:
In the paper, thermodynamic analysis of two modifications of the Brayton cycle into enhancement cycles with water or steam injection are discussed. The first one deals with a water injected gas turbine modified system with both interstage compressed air cooling and air heating (heat regeneration) before combustion chamber. The second one, mainly devoted to higher steam to air ratio, is connected with separate steam production in the heat recovery steam generator. Hence, steam utilization for the gas turbine propulsion in the Cheng cycle has been analysed. The analysis has been based on the computational flow mechanics (CFM) models of these advanced humidified systems, thanks to which, the influence of the main thermodynamic and design parameters have been examined.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2012, 124; 93-109
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka pomiarowa kotła na biomasę chłodzonego olejem w instalacji ORC
Experimental investigation of the biomass boiler cooled with thermal oil in ORC installation
Autorzy:
Kamiński, T.
Kardaś, D.
Powiązania:
https://bibliotekanauki.pl/articles/172926.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kocioł na biomasę
chłodzenie olejem
instalacja ORC
sprawność cieplna
biomass boiler
cooling with thermal oil
ORC installation
thermal efficiency
Opis:
W pracy przedstawiono wyniki badań eksperymentalnych stanowiska kotłowego należącego do laboratorium mikrosiłowni Instytutu Maszyn Przepływowych. Celem pracy było wyznaczenie bilansów energii kotła opalanego biomasą, którego zadaniem jest dostarczanie ciepła dla eksperymentalnej instalacji do produkcji ciepła i prądu w mikroskali. Specyfika mikrosiłowni polega na zastosowaniu turbiny parowej w tej skali urządzeń do produkcji prądu, co powoduje nietypowe wymaganie dotyczące kotła. Ze względu na te wymogi zastosowano olej termalny jako medium odbierające ciepło od spalin. W pracy przedstawiono charakterystyki cieplne kotła sporządzone na podstawie serii pomiarów. Badania kotła prowadzono dla rożnych wydatków paliwa, ilości powietrza oraz strumieni masy czynnika chłodzącego. Na podstawie pomiarów sporządzono wykresy parametrów chemicznych i cieplnych dla rożnych nastaw kotła.
The aim of the article was to present the testing results and the analysis of performance characteristics of a small-scale biomass-fired boiler, cooled with thermal oil. This boiler is a part of the laboratory installation for combined production of heat and electric power in micro-scale (micro CHP) in the Szewalski Institute of Fluid-Flow Machinery in Gdańsk. Both, the oil-cooled boiler and the micro CHP system, are the untypical solution in the field of electric power production. The measurements were performed for different air, oil and fuel mass flow rates.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 49-57
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance analysis and PCM selection for adsorption chiller aided by energy storage supplied from the district heating system
Autorzy:
Karwacki, Jarosław
Kwidziński, Roman
Leputa, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2204066.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal sorption cooling
phase change material
thermal energy storage
district heating
adsorption
energy management
mathematical modelling
load shifting
efficiency
Opis:
The paper presents a theoretical analysis of thermal energy storage filled with phase change material (PCM) that is aimed at optimization of an adsorption chiller performance in an air-conditioning system. The equations describing a lumped parameter model were used to analyze internal heat transfer in the cooling installation. Those equations result from the energy balances of the chiller, PCM thermal storage unit and heat load. The influence of the control of the heat transfer fluid flow rate and heat capacity of the system components on the whole system operation was investigated. The model was used to validate the selection of Rubitherm RT62HC as a PCM for thermal storage. It also allowed us to assess the temperature levels that are likely to appear during the operation of the system before it will be constructed.
Źródło:
Archives of Thermodynamics; 2022, 43, 4; 135--169
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Increasing of efficiency of the cooling duct by modification of its geometry
Autorzy:
Kiedrzyński, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/240839.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
duct electrochemical limiting current technique
ELDCT
heat mass transfer
efficiency
Opis:
Increasing of the efficiency of convective cooling of the inner surface of a short duct by changing its geometry was studied by the use of electrochemical limiting current technique (ELDCT). The duct consisted of seven identical, cylindrical segments. The changes of the duct geometry were obtained by mutual displacement of neighbouring segments, towards the radial direction. Mean values of the mass transfer coefficient for each segment and friction losses for the whole channel were measured for Reynolds numbers spanning the range 7700–35300 at the five values of displacement parameter. The results were used for estimation of cooling efficiency. Recommended values of displacement were determined to point the favourable conditions of heat/mass transfer in the duct. The results may be used, e.g. in the design of heat exchangers and channels for cooling of turbine blades and electronic equipment.
Źródło:
Archives of Thermodynamics; 2020, 41, 3; 103-123
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza efektywności chłodzenia powierzchni ściernicy z użyciem dysz schłodzonego sprężonego powietrza
Analysis of the grinding wheel surface cooling efficiency with the use of cold air guns
Autorzy:
Kieraś, S.
Nadolny, K.
Powiązania:
https://bibliotekanauki.pl/articles/269665.pdf
Data publikacji:
2015
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
chłodzenie powierzchni ściernicy
dysze sprężonego schłodzonego powietrza
temperatura
termowizja
cooling of the grinding wheel surface
cold air guns
temperature
thermovision
Opis:
Jedną z najnowszych metod chłodzenia strefy szlifowania jest doprowadzenie płynu chłodząco-smarującego w postaci schłodzonego sprężonego powietrza (SSP) z zastosowaniem dysz CAG (ang. Cold Air Guns). Podstawową zaletą tej metody jest wyeliminowanie kosztów związanych z pozyskaniem i utylizacją płynów chłodząco-smarujących. Celem badań przedstawionych w niniejszym artykule było określenie rzeczywistego efektu chłodzącego, uzyskanego na powierzchni ściernicy, wynikającego z zastosowania dysz podających schłodzone sprężone powietrze. Do badań wytypowano dwie typowe dysze CAG renomowanych producentów: WNT 6910.15.3-7 oraz Vortec 610. W przeprowadzonych badaniach porównawczych korzystniejsze wyniki analiz uzyskano dla dyszy CAG Vortec 610, dla której temperatura powierzchni ściernicy wynosiła około -5°C. W tych samych warunkach zastosowanie dyszy WNT 6910.15.3-7 pozwoliło na schłodzenie powierzchni ściernicy do około -2,5°C. Należy jednak podkreślić, że na uzyskane wyniki wpływ miały różnice w budowie elastycznych przewodów doprowadzających SSP do strefy obróbki, dlatego dokonano dodatkowych pomiarów objętościowego natężenia przepływu czynnika chłodzącego.
One of the newest methods of cooling of the grinding zone is to bring the grinding fluid in the form of cooled air using Cold Air Guns (CAG). The basic advantage of the CAG involves the use of air as the cooling medium, which is connected with the elimination of the costs associated with obtaining and utilization of grinding fluids. The aim of the research presented in this paper was to determine the actual cooling effect obtained on the grinding wheel surface, resulting from the use of CAG’s. For testing selected two typical CAG from reputable manufacturers: WNT 6910.15.3-7 and Vortec 610. In conducted comparative studies favorable results were obtained for the Vortec 610 nozzle (measured value of about -5°C). Using WNT 6910.15.3-7 nozzle under the same conditions allowed cooling down the grinding wheel surface to about -2.5°C. It should be noted, however, that the results were influenced by differences in the structure of flexible channels supplying the cold air to the machining area, and therefore additional measurements of volumetric flow rate of the coolant were made.
Źródło:
Inżynieria Maszyn; 2015, R. 20, z. 1; 50-64
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies