Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "computed tomography (CT)" wg kryterium: Wszystkie pola


Tytuł:
Simulation of computed tomography (CT) images using a Monte Carlo approach
Autorzy:
Wysocka-Rabin, A. M.
Qamhiyeh, S.
Jäkel, O.
Powiązania:
https://bibliotekanauki.pl/articles/147601.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
X-ray tomography
Monte Carlo (MC) method
treatment planning
hadrontherapy
Opis:
Heavy ion treatment planning uses an empirical scanner-dependent calibration relation between computed tomography (CT) numbers and ion range. Any deviation in the values of CT numbers will cause a drift in the calibration curve of the CT scanner, which can reduce the accuracy of treatment beam delivery. To reduce uncertainty in the empirical estimation of CT numbers, we developed a simulation that takes into consideration the geometry, composition, and physical process that underlie their measurement. This approach uses Monte Carlo (MC) simulations, followed by a simple filtered back-projection reconstruction. The MC code used is BEAMnrc/EGSnrc. With the manufacturer’s permission, we simulated the components (X-ray tube, associated filters and beam shapers) of a Siemens Emotion CT. We then generated an initial beam shape and spectra, and performed further simulations using the phantom with substitutes. We analyzed the resulting phase space file to calculate projections, taking into account the energy response of the CT detectors. Then, we applied a simple reconstruction algorithm to the calculated projections in order to receive the CT image.
Źródło:
Nukleonika; 2011, 56, 4; 299-304
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostic value of computed tomography (CT) angiography in patients with acute pulmonary embolism
Autorzy:
Zamecka, M.O.
Kurys-Denis, E.
Krupski, W.
Powiązania:
https://bibliotekanauki.pl/articles/3081.pdf
Data publikacji:
2009
Wydawca:
Instytut Medycyny Wsi
Źródło:
Journal of Pre-Clinical and Clinical Research; 2009, 03, 1
1898-2395
Pojawia się w:
Journal of Pre-Clinical and Clinical Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-dimensional reconstruction and morphometric analysis of the mandible in Van cats: A computed tomography (CT) study
Autorzy:
Yilmaz, O.
Demircioglu, İ.
Powiązania:
https://bibliotekanauki.pl/articles/2087193.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computed tomography
mandible
morphometry
three-dimensional reconstruction
Van cat
Źródło:
Polish Journal of Veterinary Sciences; 2021, 24, 2; 261-270
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości zastosowania metody tomografii komputerowej (CT) w lotnictwie
Possible application of X-ray computed tomography (CT) in aviation
Autorzy:
Chalimoniuk, M.
Kułaszka, A.
Powiązania:
https://bibliotekanauki.pl/articles/107902.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
NDT
tomografia komputerowa CT
lotnictwo
computed tomography CT
aviation
Opis:
W artykule omówione zostały możliwości zastosowania metody CT w lotnictwie. Nowoczesna nieniszcząca metoda diagnostyczna, jaką jest tomografia komputerowa, pozwala na badania praktycznie wszystkich materiałów stosowanych w szeroko rozumianej branży lotniczej - od stopów chromowo - niklowych stosowanych do produkcji łopatek turbinowych, poprzez materiały kompozytowe, aż do nawierzchni lotniskowych. Metoda ta pozwala także na badania całych agregatów, bez konieczności ich demontażu np. podczas badań komisyjnych zdarzeń lotniczych. W artykule pokazano możliwości i ograniczenia zastosowania badań metodą CT na konkretnych przykładach detali lotniczych.
The article describes the possibilities of the application of the CT method in aviation. The modern non-destructive diagnostic method, which is the computer tomography, enables to examine all materials applied in the widely understood aviation industry. From chromium-nickel alloys used to manufacture turbine blades, through composite materials, to runway pavements. This method enables to test all aggregates, without the necessity to dismantle them e.g. during commission tests of aircraft incidents. The article showed the possibilities and limitations of conducting tests with the CT method in particular examples of aircraft details.
Źródło:
Badania Nieniszczące i Diagnostyka; 2018, 3; 72-75
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The rate of decohesion of a gas turbine blade as assessed with the X-ray computed tomography (CT)
Autorzy:
Chalimoniuk, M.
Szczepanik, R
Błachnio, J.
Powiązania:
https://bibliotekanauki.pl/articles/242103.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
gas turbine
blade
maintenance status
diagnosing
X-Ray computer tomography (CT)
composite materials
Opis:
The overheating of the material is among major reasons for failures/damages to gas turbine blades throughout the entire process of operating aircraft turbine engines. The essential method of diagnosing condition of the blades is metallographic examination being however a destructive technique. The paper has been intended to discuss one of non-destructive testing (NDT) methods, i.e. the X-ray computed tomography (CT), and capabilities of applying it to diagnose changes in condition of gas turbine blades. ‘Tomography’ is a comprehensive term to define a set of diagnostic techniques to produce three-dimensional images that present cross-sections through detail items under scrutiny. The CT is a transmission diagnostic technique that allows layered models (images) of details to be acquired. Most commonly, it is used in research laboratories and throughout the process of the product quality inspection. The paper delivers findings of the preliminary investigation into the assessment of health/maintenance status of gas turbine blades by means of the X-ray computed tomography. The results gained have been successfully verified using the metallographic examination techniques. It has been found that the radiographic imaging method enables recognition of types, sizes, and locations of internal faults in the blades while generating three-dimensional images thereof. Presented are capabilities of the high-resolution X-ray inspection machine with computed tomography (CT), V/tome/x, furnished with a 300 kV tube, and the CT data processing capabilities of the VG Studio Max software solution, high-performance CT reconstruction included (using an optional module). At the same time work is under way with the X-ray tube for nanotomography with the 0.5 m resolution to examine, in particular, modern composite materials.
Źródło:
Journal of KONES; 2013, 20, 3; 89-96
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Healed or non-healed? Computed tomography (CT) visualisation of morphology of bite trace ichnotaxa on a dinosaur bone
Autorzy:
Jacobsen, A. R.
Lauridsen, H.
Fiirgaard, B.
Boel, L. W. T.
Hansen, K.
Powiązania:
https://bibliotekanauki.pl/articles/191178.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Geologiczne
Tematy:
Bite traces
dinosaur bone
theropod
CT
computed tomography
stereomicroscopy
Opis:
Bite traces on fossilised bones can provide important information on predator-prey relations and interactions in ancient environments. In 2009, two new ichnotaxa, Linichnus serratus and Knethichnus parallelum, were introduced to develop the application of bite traces as an ichnological tool. Ichnotaxa defined by theropod bite traces can provide useful information for understanding feeding behaviour. However, objective interpretation of possible bite traces can be difficult using traditional visual inspection. In this study, the bite traces on a fossilised dinosaur bone were comprehensively examined by correlating traditional naked-eye in spection with computed tomography (CT) imaging, used to visualise the internal morphology of the bite traces and in particular, to clarify the appearance of one possibly healed bite trace. A forensic pathologist visually examined the bone with the aid of stereomicroscopy and a radiologist analysed the CT scans. Sixteen different scanner settings were used to optimise the CT parameters and avoid signal at tenuation, in the form of hypointense artefacts in the central trabeculated part of the bone fragment. The use of CT scanning provided information on internal morphology from the vicinity of the bite trace, including hyperdense zones, not identified using visual inspection alone. By applying the extended CT scale, the dense and radiopaque cortical bone layer could be clearly identified and applied as a pathomorphological marker to correctly distinguish non-healed from healed wounds. In conclusion, the authors demonstrate that external visual examination of trace fossils by ichnologists in combination with interior examination using CT imaging can be applied to characterise ichnotaxa defined by bite traces and potentially provide clues on ancient feeding behaviour.
Źródło:
Annales Societatis Geologorum Poloniae; 2015, 85, 3; 457-464
0208-9068
Pojawia się w:
Annales Societatis Geologorum Poloniae
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tomograficzna ocena jakości odlewów ze stopu Haynes 282
Quality check of H282 castings by Computed Tomography (CT) technique
Autorzy:
Krzak, I.
Tchórz, A.
Pirowski, Z.
Jaśkowiec, K.
Grudzień, M.
Purgert, R.
Powiązania:
https://bibliotekanauki.pl/articles/391747.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
rentgenowska tomografia komputerowa (CT)
nieciągłości strukturalne
nadstopy niklu
Haynes 282
X-ray computed tomography (CT)
structural discontinuity
nickel superalloys
Opis:
W ramach prac projektu międzynarodowego realizowanego w Instytucie Odlewnictwa w Krakowie we współpracy z Energy Industries of Ohio opracowano technologię topienia w otwartym piecu indukcyjnym i grawitacyjnego odlewania nadstopów niklu. Dotychczas nadstopy te stosowane były wyłącznie jako przerabiane plastycznie. Do kontroli jakości wykonanych odlewów ze stopu Haynes 282 (H282) zastosowano między innymi rentgenowską tomografię komputerową (ang. Computed Tomography, CT). Jest to metoda nieniszcząca, która łączy badania rentgenowskie z zaawansowaną technologią komputerową. W niniejszej pracy zaprezentowano wybrane przykłady uzyskanych wyników badań zrealizowanych za pomocą rentgenowskiego tomografu komputerowego firmy GE Phoenix typu v/tome/x l-450 będącego na wyposażeniu Instytutu Odlewnictwa. Wszystkie operacje związane z obróbką danych z CT były wykonywane za pomocą oprogramowania datos/x - reconstruction i VGStudio Max 2.0.
As a part of the international project carried out at the Foundry Research Institute in Krakow in cooperation with Energy Industries of Ohio, anopen induction furnace melting technology and gravity casting of nickel superalloys have been developed. These alloys have been processed plastically so far. Quality control of Haynes 282 alloy (H282), was made with X-ray computed tomography (CT). CT is a non-destructive method that combines X-ray examinations with advanced computer technology. Selected results of the research obtained from the X-ray computer tomograph have been presented in the paper. Research were made by using the GE Phoenix v/ tome/x l-450 tompgraph type belonging to the Foundry Research Institute equipment. All operations related to the processing of CT data were performed using the datos/x-reconstruction and VGStudio Max 2.0 software.
Źródło:
Prace Instytutu Odlewnictwa; 2018, 58, 4; 219-225
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Progress in Digital Industrial Radiology. Pt. 2, Computed tomography (CT)
Postępy w cyfrowej radiografii przemysłowej. Cz. 2, Tomografia komputerowa
Autorzy:
Ewert, U.
Fuchs, T.
Powiązania:
https://bibliotekanauki.pl/articles/107921.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
digital radiography
computed tomography
laminography
CFRP
aerospace
automotive
radiografia cyfrowa
tomografia komputerowa
laminografia
kompozyty węglowe
przemysł lotniczy
przemysł motoryzacyjny
Opis:
Part 1: Film Replacement and Backscatter Imaging. The related paper was published in Vol 1-2/2016 of this journal. Part 2: Computed tomography (CT). Applications cover the range from nano-meter to meter scale. New specialized high energy CT devices have been laid out for inspection of large building structures or complete cars before and after crash tests. The scope of typical CT applications changes from flaw detection to dimensional measurement in industry substituting coordinate measurement machines. First applications of at line or in line inspection in production lines of car industry are discussed. CT is applied for a variety of applications, where selected areas as e.g. plant and food research in outlined. Mobile computed tomography is applied for in-service radiographic crack detection and sizing of welded pipes in nuclear power plants and for NDT of large CFRP structures of airplanes. Part 3: Micro Radiography and Micro CT. To be published in this journal.
Podobnie jak w przypadku zakończonego sukcesem wdrożenia fotografii cyfrowej, bardzo istotne zmiany można zaobserwować także w cyfrowej radiologii przemysłowej. Niniejsza praca jest podzielona na 3 części: Część 1: Następca błony radiograficznej i obrazowanie za pomocą rozproszenia wstecznego – publikacja ukazała się w wydaniu Nr1-2/2016 tego czasopisma. Część 2: Tomografia komputerowa (CT). Zastosowania tomografii obejmują obiekty o wielkości od nanometrów do metrów. Nowe dedykowane urządzenia wysokoenergetycznej tomografii komputerowej skonstruowano w celu inspekcji dużych konstrukcji budowlanych czy też całych samochodów przed i po testach zderzeniowych. Cel typowego zastosowania tomografii komputerowej uległ zmianie z detekcji wad na wymiarowanie wyrobów przemysłowych, co spowodowało zastąpienie współrzędnościowych maszyn pomiarowych. W pierwszej kolejności omówiono zastosowanie tomografii komputerowej na liniach produkcyjnych w przemyśle samochodowym. Tomografia komputerowa ma wiele zastosowań, w tym np. badanie roślin i żywności. Przenośne tomografy komputerowe wykorzystywane są do wykrywania defektów i wymiarowania spawanych rur w elektrowniach jądrowych, a także do inspekcji dużych elementów konstrukcji lotniczych wykonanych z kompozytów węglowych. Część 3: Mikroradiografia i mikrotomografia komputerowa.
Źródło:
Badania Nieniszczące i Diagnostyka; 2017, 1-2; 7-14
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnozowanie uszkodzeń BVID w materiałach kompozytowych metodą tomografii komputerowej (CT)
BVID damage diagnosis in composite materials using computed tomography (CT) method
Autorzy:
Nidzgorska, Adrianna
Perczyński, Jerzy
Chalimoniuk, Marek
Kułaszka, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2200299.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
kompozyt
tomograf
badanie
uszkodzenia typu BVID
composite
tomograph
research
barely visible impact damage
BVID
Opis:
Uszkodzenia BVID (ang. Barely Visible Impact Damage) w polimerowych materiałach kompozytowych elementów konstrukcji lotniczych pojawiają się w wyniku oddziaływania na nie dynamicznych obciążeń ciał obcych (FOD - ang. Foreign Object Damage), takich jak np. narzędzia, grad, kamienie itp., o małych prędkościach i niewielkich energiach. Uszkodzenia tego typu można zaliczyć zarówno do grupy uszkodzeń eksploatacyjnych jak i produkcyjnych. Z punktu widzenia eksploatacji są one szczególnie niebezpieczne, ponieważ charakteryzują się słabą wykrywalnością powszechnie stosowanymi metodami diagnostycznymi np. metodą wizualną, jednocześnie propagując wewnątrz materiału. Tomografia komputerowa (CT - ang. Computed Tomography) jest rodzajem tomografii rentgenowskiej pozwalającym na uzyskanie obrazów przestrzennych (3D) z prześwietlania badanego obiektu wykonanych z różnych kierunków. Umożliwia ona wykrycie nieciągłości materiału oraz wiarygodną ocenę badanych elementów. Z tego powodu metoda ta znalazła zastosowanie do skutecznej weryfikacji uszkodzeń typu BVID na wczesnym ich etapie, wpływając w znacznym stopniu na bezpieczeństwo eksploatacji.
Damages type Barely Visible Impact Damage (BVID) in polimer composite materials of airborne construction elements occur as a result of dynamic loads interaction caused by Foreign Object Damage (FOD) such as tools, hail, stones etc. with low velocities and energies. There are both exploitation and production type of BVID damages. They are especially dangerous from exploitation point of view because they are characterized by insufficient visual detectability while using common methods like visual method, but they spread into the material at the same time. Computed tomography (CT) is a type of X-ray tomography that allows to get 3D pictures from scanning examined object from different directions. It enables for detecting material discontinuities and reliable assessment of the researched elements. For this reason CT method has been used in effective BVID damages verification in their early stage and has an enormous influence on the exploitation safety.
Źródło:
Badania Nieniszczące i Diagnostyka; 2022, 1-4; 23--27
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic Extraction of the Pelvicalyceal System for Preoperative Planning of Minimally Invasive Procedures
Autorzy:
Heryan, K.
Skalski, A.
Jakubowski, J.
Drewniak, T.
Gajda, J.
Powiązania:
https://bibliotekanauki.pl/articles/220364.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pelvicalyceal system segmentation
kidney segmentation
kidney compartments
Computed Tomography (CT)
kidney cancer
Opis:
Minimally invasive procedures for the kidney tumour removal require a 3D visualization of topological relations between kidney, cancer, the pelvicalyceal system and the renal vascular tree. In this paper, a novel methodology of the pelvicalyceal system segmentation is presented. It consists of four following steps: ROI designation, automatic threshold calculation for binarization (approximation of the histogram image data with three exponential functions), automatic extraction of the pelvicalyceal system parts and segmentation by the Locally Adaptive Region Growing algorithm. The proposed method was applied successfully on the Computed Tomography database consisting of 48 kidneys both healthy and cancer affected. The quantitative evaluation (comparison to manual segmentation) and visual assessment proved its effectiveness. The Dice Coefficient of Similarity is equal to 0.871 ± 0.060 and the average Hausdorff distance 0.46 ± 0.36 mm. Additionally, to provide a reliable assessment of the proposed method, it was compared with three other methods. The proposed method is robust regardless of the image acquisition mode, spatial resolution and range of image values. The same framework may be applied to further medical applications beyond preoperative planning for partial nephrectomy enabling to visually assess and to measure the pelvicalyceal system by medical doctors.
Źródło:
Metrology and Measurement Systems; 2017, 24, 1; 3-18
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing the representative elementary volume of rock types by X-ray computed tomography (CT) – a simple approach to demonstrate the heterogeneity of the Boda Claystone Formation in Hungary
Autorzy:
Abutaha, Saja M.
Geiger, János
Gulyás, Sándor
Fedor, Ferenc
Powiązania:
https://bibliotekanauki.pl/articles/2204358.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
Hounsfield Unit
HU
autoregressive integrated moving average
ARIMA
Statistical Process Control
SPC technique
skala Hounsfielda
model ARIMA
statystyczna kontrola procesu
SPC
Opis:
X-ray computed tomography (CT) can reveal internal, three-dimensional details of objects in a non-destructive way and provide high-resolution, quantitative data in the form of CT numbers. The sensitivity of the CT number to changes in material density means that it may be used to identify lithology changes within cores of sedimentary rocks. The present pilot study confirms the use of Representative Elementary Volume (REV) to quantify inhomogeneity of CT densities of rock constituents of the Boda Claystone Formation. Thirty-two layers, 2 m core length, of this formation were studied. Based on the dominant rock-forming constituent, two rock types could be defined, i.e., clayey siltstone (20 layers) and fine siltstone (12 layers). Eleven of these layers (clayey siltstone and fine siltstone) showed sedimentary features such as, convolute laminations, desiccation cracks, cross-laminations and cracks. The application of the Autoregressive Integrated Moving Averages, Statistical Process Control (ARIMA SPC) method to define Representative Elementary Volume (REV) of CT densities (Hounsfield unit values) affirmed the following results: i) the highest REV values corresponded to the presence of sedimentary structures or high ratios of siltstone constituents (> 60%). ii) the REV average of the clayey siltstone was (5.86 cm3) and (6.54 cm3) of the fine siltstone. iii) normalised REV percentages of the clayey siltstone and fine siltstone, on the scale of the core volume studied were 19.88% and 22.84%; respectively. iv) whenever the corresponding layer did not reveal any sedimentary structure, the normalised REV values would be below 10%. The internal void space in layers with sedimentary features might explain the marked textural heterogeneity and elevated REV values. The drying process of the core sample might also have played a significant role in increasing erroneous pore proportions by volume reducation of clay minerals, particularly within sedimentary structures, where authigenic clay and carbonate cement were presumed to be dominant.
Źródło:
Geologos; 2021, 27, 3; 157--172
1426-8981
2080-6574
Pojawia się w:
Geologos
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rentgenowska tomografia komputerowa(CT) do zadań przemysłowych
X-ray computed tomography for industrial tasks
Autorzy:
Ratajczyk, E.
Powiązania:
https://bibliotekanauki.pl/articles/277326.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
tomograf komputerowy CT
lampa rtg
detektor
defektoskopia
model CAD
inżynieria odwrotna
computed tomography CT
detector
X-rays radiations
flaw detection
X-ray tube
reverse engineering
Opis:
W artykule przedstawiono najnowszą generację urządzeń pomiarowych wchodzących do przemysłu i jednostek badawczych, a mianowicie tomografię komputerową CT. Opisano istotę pomiarów tomograficznych, zasadę działania i budowę tomografów, ich funkcje i oprogramowanie. Następnie przedstawiono liczne przykłady zastosowań w wyznaczaniu wymiarów geometrycznych, zarówno w odniesieniu do modelu CAD, jak i tworzeniu modelu w zakresie inżynierii odwrotnej. Przedstawiono również przykłady wykrywania wad materiału w defektoskopii.
This paper presents the latest generation of measuring devices being introduced into the industry and research units, namely, computed tomography CT. The essence of tomography measurements, principles of operation and construction of scanners, their functions and software are described. Then presents several examples of applications in determining the geometrical dimensions of both the CAD model and creating a model for reverse engineering are presented. It also presents examples of flaw detection in revealing of defects in the material.
Źródło:
Pomiary Automatyka Robotyka; 2012, 16, 5; 104-113
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tomografia komputerowa w pomiarach geometrycznych 3D
Computed tomography in 3D geometrical measurements
Autorzy:
Ratajczyk, E.
Powiązania:
https://bibliotekanauki.pl/articles/151191.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
tomografia komputerowa-TC
lampa rentgenowska
promieniowanie X
współrzędnościowa technika pomiarowa
computed tomography CT
detector
coordinate measuring systems
X-rays radiations
rotary tables
X-ray tube
Opis:
Istota pomiarów tomograficznych opartych na promieniowaniu rentgenowskim X. Budowa tomografów - główne zespoły i ich funkcje. Kalibracja tomografów. Prezentacja modelu tomografu opracowanego w Instytucie Metrologii i Inżynierii Biomedycznej.
Computed tomography (CT), after its dynamical development for medical requirements recently starts to appear in an area of industrial applications. It enables not only to determine dimensions of objects made of metal, plastics and different kinds of composed materials but also to defect internal defects of the material. This paper describes concepts of CT measurements. The main construction units of tomographs are characterized and the examples of tomographs of different firms and their applications are given. The accuracy and calibration problems are also shortly discussed. At the and the concepts of home - made computed tomograph for industrial applications are also presented.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 2, 2; 220-223
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie rentgenowskiej tomografii komputerowej do porównania metody niskociśnieniowego odlewania przeciwgrawitacyjnego i metody odlewania grawitacyjnego
Application of X-ray computed tomography to compare gravity casting to counter-gravity low-pressure air-melted process
Autorzy:
Krzak, I.
Jaśkowiec, K.
Tchórz, A.
Boroń, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/391421.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
niskociśnieniowe odlewanie przeciwgrawitacyjne (CLA)
rentgenowska tomografia komputerowa (CT)
nieciągłość strukturalna
counter-gravity low-pressure air-melted casting (CLA)
X-ray computed tomography (CT)
structural discontinuities
Opis:
Celem niniejszej pracy była ocena struktury wewnętrznej odlewów zbliżonych do AlSi9Mg (EN AC-43300), wykonanych metodą niskociśnieniowego odlewania przeciwgrawitacyjnego w atmosferze powietrza – CLA (Counter-gravity Low-pressure Air-melted – powietrzne, niskociśnieniowe odlewanie przeciwgrawitacyjne) oraz metodą grawitacyjną. Metodę rentgenowskiej tomografii komputerowej – CT (Computed Tomography) w połączeniu z badaniami strukturalnymi i mechanicznymi, zastosowano do oceny jakości odlewów wytworzonych wyżej wymienionymi technikami. Nieciągłości strukturalne odlewów wykonanych metodą CLA i metodą grawitacyjną zbadano, analizując wyniki prześwietlania przemysłowym tomografem komputerowym firmy Phoenix X-ray. Przykładowo przedstawiono je w postaci wybranych przekrojów (2D) i w wizualizacji przestrzennej (3D). Z uwagi na fakt, że same badania tomograficzne okazały się niewystarczające, dla porównania jakości odlanych próbek różnymi technikami, przeprowadzono badanie mikrostruktury z wykorzystaniem mikroskopu świetlnego oraz wykonano statyczną próbę rozciągania próbek w temperaturze otoczenia.
The purpose of this paper is to evaluate the internal structure of alloys similar to AlSi9Mg (EN AC-43300), made with the counter-gravity low-pressure air-melted process (CLA) and with the gravity casting process. The X-ray computed tomography (CT) examination method was combined with structural and mechanical testing for a qualitative evaluation of the castings produced with these processes. The structural discontinuities in CLA and gravity castings were investigated by studying the imaging made with an industrial- grade CT scanner manufactured by Phoenix X-ray. The examples of images are shown on selected cross-sections (2D) and by 3D visualisation. The CT examination proved to be insufficient for a qualitative comparison of castings produced with different techniques; hence a microstructural examination was carried out under an optical microscope and a static tensile test was completed on the samples at ambient temperature.
Źródło:
Prace Instytutu Odlewnictwa; 2015, T. 55, nr 1, 1; 11-21
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przegląd dostępnego oprogramowania do sterowania ścieżką pracy głowicy dla personalnych drukarek przestrzennych
Review of available software for path control of personal 3D printers toolheads
Autorzy:
Olejarczyk, M.
Gruber, K.
Ziółkowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/134817.pdf
Data publikacji:
2015
Wydawca:
ADVSEO
Tematy:
AM
FDM
drukarki personalne 3D
personalne drukarki przestrzenne
personal 3D printers
fused deposition modeling (FDM)
computed tomography (CT)
3D printers software
Opis:
Personal 3D printers, based on fused deposition modeling (FDM) technology, established a relatively new category in Additive Manufacturing (AM) systems. Adding material layer by layer allows to manufacture complex parts at low cost. Recent dynamic demand growth in this segment forced 3D printer manufacturers to simultaneously develop machines and dedicated software, which enables to convert CAD 3D model to toolhead path control codes (G-code). The work presented in this paper compares currently available 3D printers software: Cura, Slic3r, Voxelizer, Matter Control. The aim of presented study was to investigate dimensions and shape precision of test specimens using computed tomography (CT). Specimens used in the study were designed to capture a representative set of geometrical features for comparison. Specimens were made of PLA (polylactide), a widely used FDM material, on Hbot 3D (personal 3D printer from 3D Printers Ltd, Poland). CT systems enable to measure external and internal dimensions with high precision. In the study, analysis of specimens external geometry, including diameters, distances and angles measurement, was performed. Standard deviation was estimated through comparison of reference values from CAD model with measurement results. In order to analyze the internal geometry, cross-section verification was done. The fundamental result of the paper demonstrates the influence of different 3D printer software on geometrical accuracy. Although the most important process parameters for each software were set up in the same way, there were significant differences between the models. Based on these results, it is concluded that the best results were obtained using Cura software.
Źródło:
Technical Issues; 2015, 3; 48-55
2392-3954
Pojawia się w:
Technical Issues
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie rentgenowskiej tomografii komputerowej do wspomagania badań materiałowych odlewów
The use of X-ray computed tomography as a tool in assisting cast material testing
Autorzy:
Krzak, I.
Tchórz, A.
Powiązania:
https://bibliotekanauki.pl/articles/391540.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
rentgenowska tomografia komputerowa (CT)
badania defektoskopowe
niskociśnieniowe odlewanie przeciwgrawitacyjne (CLA)
szybkie prototypowanie (RP)
inżynieria odwrotna (RE)
X-ray computed tomography (CT)
flaw detection
counter-gravity low-pressure air-melted casting (CLA)
Rapid Prototyping (RP)
reverse engineering (RE)
Opis:
Technologia wytwarzania odlewów zależna jest od wielu czynników. Warunki techniczne odbioru odlewów określają wymaganą jakość, co jest podstawą do uznania odlewu za dopuszczalny bądź wadliwy. W praktyce produkcja odlewów bez pewnej ilości sztuk wadliwych nie jest możliwa. Dąży się jednak do zminimalizowania strat, stosując różnorodną aparaturę kontrolno-pomiarową. Do sprawdzenia wewnętrznej struktury wyrobu pomocna może być rentgenowska tomografia komputerowa (ang. Computed Tomography – CT). Jest to nowoczesna metoda diagnostyczna, która łączy badania rentgenowskie z zaawansowaną technologią komputerową. Badania tomograficzne umożliwiają bezinwazyjną jakościową ocenę badanego materiału oraz przeprowadzenie zaawansowanych analiz. Jedną z podstawowych zalet rentgenowskiej tomografii CT jest zobrazowanie badanych struktur w trzech wymiarach oraz możliwość wykonania rekonstrukcji przestrzennych. Przedmiotem artykułu jest przybliżenie zasady działania rentgenowskiej tomografii komputerowej oraz omówienie szerokiego jej wykorzystania w różnych dziedzinach nauki, w szczególności w badaniach defektoskopowych, w ilościowych badaniach metalograficznych, w procesie inżynierii odwrotnej (rekonstrukcyjnej) oraz w badaniach metrologicznych. Na wybranych przykładach przedstawiono możliwości rentgenowskiej tomografii komputerowej.
Casting manufacture depends on many factors. Technical specifications determine the required quality, which is essential for casting acceptance or rejection. Practice shows that making castings without defects is simply not possible. However, the aim is to minimize rejects owing to the use of diverse instruments for measurements and control. A tool which may be helpful in checking the internal structure of products is the X-ray computed tomography (CT). CT is a modern diagnostic method that combines X-ray examinations with advanced computer technology. Tomographic studies allow non-destructive qualitative assessment of the test material combined with advanced analysis. One of the main advantages of the X-ray computed tomography is imaging of the examined structure in three dimensions and the ability to perform spatial reconstruction. The aim of this article is to describe the principle operation of X-ray computed tomography and offer extensive discussion of its use in various fields of science, in particular to defect detection, quantitative metallographic tests, the process of reverse engineering (reconstruction) and metrological studies. Selected examples were used to show the potential offered by this technique.
Źródło:
Prace Instytutu Odlewnictwa; 2015, T. 55, nr 3, 3; 33-42
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected features of carbonate rocks based on the X-ray computed tomography method (CT)
Wybrane cechy skał węglanowych w odwzorowaniu rentgenowskiej tomografii komputerowej (CT)
Autorzy:
Urbaniec, A.
Drabik, K.
Dohnalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/1835191.pdf
Data publikacji:
2018
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
X-ray computed tomography
carbonate rocks
texture features
biogenic structures
porosity
fractures
rentgenowska tomografia komputerowa
skały węglanowe
cechy teksturalne
struktury biogeniczne
porowatość
szczeliny
Opis:
The paper presents possibilities of X-ray computed tomography (CT) application in view of representing selected features of carbonate rocks in a CT image. 72 sections of drill cores, approx. 1 m long each, were selected for tomographic examinations to obtain as reliable as possible results. The selected core material represents carbonate formations of various ages (from Palaeozoic to Upper Cretaceous), originating from boreholes situated in the Carpathian Foreland area. The interpretation of tomographic examinations was connected with a detailed sedimentological analysis of selected core sections, allowing to carry out direct comparisons, which of studied features and to what extent have disclosed in the CT images, and also whether this image can supplement or make the prepared descriptions more detailed. The presented information has a qualitative nature, i.e. referring mainly to descriptive features of the analysed carbonate rocks. Because of a limited size of the paper we have focused only on a few from numerous analysed features of carbonate rocks. The method of X-ray computed tomography (CT) can be very helpful at the analysis of various carbonate rocks features, such as structural and textural features, biogenic structures, porosity, and fracturing. It should be emphasised that this is a non-invasive method, providing a possibility to reproduce the CT image in various directions, without the necessity of mechanical interference in the rock material, resulting in the core destruction. Mummified siliceous sponges were examples of biogenic structures, which were best reflected in formations, which have been subjected to processes of selective dolomitization. In such type of carbonate rocks the sponge mummies were not dolomitized, while the basic material of the background was dolomitized. A very good representation of the structure in CT images was obtained for colonial hexacorals from the Scleractinia group, because many details of their skeleton structure are noticeable. Contrary to siliceous sponges the structure of corals is preserved much worse in the case, when the studied deposits were subject to diagenetic processes (such as dissolution, recrystallisation, or dolomitization). In addition, the analysis of various bioclasts, preserved in carbonate rocks, has shown a significant role both of the original mineral component building the skeletal elements of organisms (aragonite, high-magnesium calcite, lowmagnesium calcite), and of diagenetic processes history, directly affecting the condition of those components preservation. Based on the analysed materials it was found that porosity and fracturing are among best reflected features of carbonate rocks in the CT image. Open fractures, fractures filled with anhydrite and fractures filled with clay-marly material are generally well reflected in the CT image. Instead, fractures filled with calcite are variously recognisable, depending on the mineral composition of the rock background.
W artykule przedstawiono możliwości wykorzystania rentgenowskiej tomografii komputerowej (CT) pod kątem odzwierciedlenia wybranych cech skał węglanowych w obrazie CT. Do badań tomograficznych wytypowano 72 odcinki rdzeni wiertniczych o długości ok. 1 m każdy w celu uzyskania możliwie najbardziej wiarygodnych wyników. Wytypowany materiał rdzeniowy reprezentuje utwory węglanowe różnego wieku (od paleozoiku po górną kredę), pochodzące z otworów wiertniczych, zlokalizowanych na obszarze przedgórza i w podłożu Karpat. Interpretację badań tomograficznych powiązano ze szczegółową analizą sedymentologiczną wybranych odcinków rdzeni, co pozwoliło na bezpośrednie porównanie, które z badanych cech i w jakim stopniu ujawniły się w obrazie tomograficznym, a także czy obraz ten jest w stanie uzupełnić lub uszczegółowić wykonane opisy. Przedstawione informacje mają charakter jakościowy, tj. odnoszący się głównie do cech opisowych analizowanych skał węglanowych. W związku z ograniczoną objętością artykułu skoncentrowano się jedynie na kilku spośród wielu przeanalizowanych cech skał węglanowych. Metoda rentgenowskiej tomografii komputerowej (CT) może być bardzo pomocna przy analizie różnego typu ich cech, takich jak: cechy strukturalne i teksturalne, struktury biogeniczne, porowatość, szczelinowatość. Należy podkreślić, że jest to metoda nieinwazyjna, dająca możliwość odtwarzania obrazu tomograficznego w różnych kierunkach, bez konieczności mechanicznej ingerencji w materiał skalny, prowadzącej do niszczenia rdzenia. Spośród przeanalizowanych struktur biogenicznych uwagę zwrócono na zmumifikowane gąbki krzemionkowe, które w najlepszym stopniu odwzorowane zostały w zapisie CT w utworach, które w trakcie diagenezy poddane zostały procesom selektywnej dolomityzacji. W tego typu utworach mumie gąbek nie uległy dolomityzacji, podczas gdy masa podstawowa otaczającego osadu została zdolomityzowana. Bardzo dobre odzwierciedlenie struktury w zapisie CT uzyskano dla kolonijnych koralowców sześciopromiennych z grupy Scleractinia, gdyż w obrazie tomograficznym dostrzegalnych jest wiele detali budowy ich szkieletu. W przeciwieństwie do gąbek krzemionkowych, struktura koralowców zachowana jest znacznie gorzej w przypadku, gdy badane utwory poddane zostały w większym stopniu procesom diagenetycznym (takim jak rozpuszczanie, rekrystalizacja czy też dolomityzacja). Ponadto analiza różnego typu bioklastów, zachowanych w skałach węglanowych, wykazała istotną rolę, zarówno pierwotnego składnika mineralnego budującego elementy szkieletowe organizmów (aragonit, kalcyt wysokomagnezowy, kalcyt niskomagnezowy), jak również historii procesów diagenetycznych, mających bezpośredni wpływ na stan zachowania tych elementów. Na podstawie przeanalizowanych materiałów stwierdzono, że porowatość i szczelinowatość są jednymi z najlepiej odwzorowanych w zapisie tomograficznym cech skał węglanowych. W obrazie CT na ogół w bardzo dobrym stopniu czytelne są szczeliny otwarte, szczeliny wypełnione anhydrytem oraz szczeliny wypełnione materiałem ilasto-marglistym. Natomiast szczeliny zabliźnione kalcytem rozpoznawalne są w różnym stopniu, w zależności od składu mineralnego tła skalnego.
Źródło:
Nafta-Gaz; 2018, 74, 3; 183-192
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie 3D struktury przestrzeni porowej cementów metodą mikrotomografii rentgenowskiej (micro-CT)
Examination of internal pore space 3D images of cement rock with use of Roentgen Computed Tomography (Micro-CT)
Autorzy:
Dohnalik, M.
Zalewska, J.
Kut, Ł.
Kaczmarczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/349787.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
cement
struktura porowa kamieni cementowych
rozwój porowatości
mikrotomografia
cement rock pore structure
pore structure evolution
microtomography
Opis:
Metoda mikrotomografii rentgenowskiej (micro-CT) jest nieniszczącą metodą badawczą, która umożliwia wizualizację budowy wewnętrznej obiektów (w geologii np. skał i cementów). Metoda polega na rejestracji projekcji promieniowania X badanej próbki pod różnymi kątami, a następnie rekonstrukcji na tej podstawie struktury wewnętrznej próbki. Wizualizowanym parametrem jest współczynnik atenuacji liniowej, który zależy od energii promieniowania X, liczby atomowej pierwiastków budujących obiekt oraz gęstości badanej próbki. Micro-CT może być stosowana zarówno do jakościowej wizualizacji wewnętrznej struktury cementów, jak również do pozyskiwania danych ilościowych. Celem tego artykułu jest przedstawienie zastosowania mikrotomografii rentgenowskiej w badaniu cementów. W pracy zaprezentowano, po raz pierwszy w kraju, wyniki mikrotomograficznych badań mikrostruktury zaczynów cementowych w różnym wieku (1 do 28 dni). Wyniki pozwoliły przeanalizować zmiany w sieci porowej zaczynów podczas ich starzenia. Wykazano znaczące różnice w ewolucji porów pomiędzy próbami zaczynów o różnych składach. Wyniki te pokazują możliwości metody micro-CT w badaniu materiałów cementowych. Główną zaletą metody jest możliwość odtworzenia sieci porowej oraz prześledzenia zmian wielkości porów w czasie. Dzięki tej metodzie możliwe jest także badanie nowych cech, takich jak dystrybucja przestrzenna struktury porowej oraz określenie jej przewodności.
The X-ray computed microtomography (micro-CT) is a non-destrictive method for visualization of objects' internal structures (in geology - e.g. rocks or cement stones). Sample's X-ray projections at different angles are recorded and, on the basis of them, the objects' internal structure is reconstructed. Visualized parameter is the linear attenuation coefficient (proportional to X-ray's energy, material's density and atomic number of elements in object's structure). The micro-CT may be used to visualize the cement's internal structure and its quantitative analysis. The aim of this paper is to show application of micro-CT in cementary rocks examination. In this work the results of micro-CT measurement for cements of different age (1-28 days) are shown first time in Poland. Obtained results allowed to analyze changes of pore network during the cement rock's shrinking. Significant pore space evolution changes in case of cement rocks with different composition were observed. Results shown that micro-CT method is applicable for cement rocks examination. The main adventage of micro-CT is the ability to reconstruction of pore space and observation of its changes in time. Also the pores' spatial distribution and tortuosity may be examined.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 4; 157-165
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of the Computed Tomography Results of Aluminum Alloy Welded Joint
Autorzy:
Malicki, M.
Sobczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/97855.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
computed tomography
CT
welded joints
defects
microcracks
Opis:
Computed tomography (CT) of aluminum welded joint specimen has been performed. On the tomographic cross sections some defects have been found. To verify them the metallography cross sections of welded has been done. It was found that selected defects are micro cracks.
Źródło:
Fatigue of Aircraft Structures; 2018, 10; 47-52
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The defect analysis of Inconel 738LC with computed tomography inspection
Autorzy:
Ciećko, Andrzej
Kamiński, Łukasz
Wierzba, Patrycja
Powiązania:
https://bibliotekanauki.pl/articles/175802.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computed tomography
CT
material defects
Inconel 738LC
tensile test
chemical analysis
material properties
nondestructive
Inconel
Opis:
In the present paper, computed tomography (CT) inspection is shown. The CT inspection method allowed to rate the density of defects hidden inside a material, which has a significant role in the live material. The method allows to evaluate the reliability of tensile test’s results. In our analysis, the position of crack propagation was determined by CT, and the tensile test was performed to check the accuracy of the nondestructive method. The tensile tests were performed on Inconel 738LC [1] samples.
Źródło:
Advances in Manufacturing Science and Technology; 2020, 44, 3; 80-83
0137-4478
Pojawia się w:
Advances in Manufacturing Science and Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie wyników badań metrologicznych uzyskanych za pomocą rentgenowskiej tomografii komputerowej i skanera optycznego 3D
Comparison of the results of metrological tests obtained from X-ray computed tomography and optical 3D scanner
Autorzy:
Tchórz, A.
Gil, A.
Powiązania:
https://bibliotekanauki.pl/articles/391594.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
metrologia 3D
skanowanie 3D
rentgenowska tomografia komputerowa (X-ray CT)
optyczny skaner 3D
metrology 3D
3D scanning
X-ray computed tomography (X-ray CT)
optical 3D scanner
Opis:
Istotnym czynnikiem decydującym o jakości wyrobów jest wprowadzenie nowych metod w dziedzinie metrologii technicznej. W pracy przedstawiono metodykę analizy badań metrologicznych uzyskanych za pomocą tomografu komputerowego i skanera optycznego 3D. Urządzenia te umożliwiły uzyskanie wirtualnych obiektów oraz pozwoliły na przeprowadzenie trójwymiarowych analiz przestrzennych. Przedstawiono zasadę działania tych urządzeń oraz przeanalizowano ich możliwości na przykładzie wytypowanych odlewów. Wyniki badań przedstawiono za pomocą określonych wymiarów oraz mapy kolorów na powierzchni modelu. Dokonano oceny dokładności pomiarów w poszczególnych metodach.
The launch of new methods in the technical metrology area is a material factor determining the quality of the products. The paper presents the methodology of analysis of metrological tests conducted with the use of computed tomography and an optical 3D scanner. These devices allowed us to obtain virtual objects and conduct 3D spatial analyses. The paper presents the operating principle of these devices and analyses their capabilities based on selected castings. The results of the tests are presented with the support of determined dimensions and colour maps on the model surface. The accuracy of measurements in individual methods was assessed.
Źródło:
Prace Instytutu Odlewnictwa; 2014, T. 54, nr 4, 4; 63-75
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Validation of microscopy measured porosity in carbon fibbers composites
Autorzy:
Jędral, Arnold
Bona, Anna
Powiązania:
https://bibliotekanauki.pl/articles/244963.pdf
Data publikacji:
2019
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
porosity
carbon fibre
microscope
UT
Ultrasonic test
CT
computed tomography
Opis:
One of the most common defects in carbon fibrereinforced plastics (CFRP) is porosity. Too much of those defectscould be serious problemsto mechanical properties, which directly take effect on elements safety, like aircrafts. Therefore, the evaluation of porosity is very important test. Microscopic observations are widely used as a quality instrument in materials and constructions inspections. Cross section image of a material is easy to prepare and analyse. Porosity of a carbon fibrereinforced plasticcan be clearly spot in such kind of images. Study shows that in the most cases porosity appear between layers of fibres , rather between fibres. Unfortunately,image from microscope is only 2D picture from a small representative region. Because of that,comparison of 2D image to a real porosity distribution in all volume of a material is very difficult. To verify 2D microscopic observation method is necessary to perform another kind of tests. In this article , authors focused on non-destructive (NDT) and destructive testing methods. 2D porosity images from light microscope were compared with three different testing methods: ultrasonic test (UT), computed tomography (CT) test and constituent content of composite materials standard test method according to ASTM D3171 – 15, procedure B. Porosity results obtained from dissolution of resin from the carbon-epoxy resin sample.
Źródło:
Journal of KONES; 2019, 26, 4; 83-90
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The prevalence of incidental findings in computed tomography of the head in Pediatric Emergency Department
Autorzy:
Lipińska, Justyna
Lipiński, Łukasz
Kopeć, Izabela
Kowalczuk, Maria
Woźniak, Magdalena Maria
Powiązania:
https://bibliotekanauki.pl/articles/40555844.pdf
Data publikacji:
2024-06-30
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
head CT incidental findings
pediatric ED
pediatric head CT
Opis:
Introduction and aim. Computed tomography (CT) is the first imaging modality in the evaluation of children in case of patients with head injury in pediatric Emergency Departments (EDs). Radiological CT reports include not only lesions that are the main cause of the child’s complaints but also incidental findings. The objective of this study is to assess incidental findings observed in children who were admitted to the ED and had the head CT performed. Material and methods. This retrospective, cross-sectional study enrolled 644 children under the age of 18, from 1st January 2021 to 31st June 2021. Each child could have had one or more incidental findings in CT. Results. Among all CT studies, incidental findings were found in 279 out of 644 (43.32%) cases, of which 73 (11.34%) had both lesions detected incidentally and related to the trauma. Conclusion. Head CT is an incredibly useful tool in the assessment of some head emergencies. However, evaluation of the prevalence of incidental findings is difficult. Most of them require no specific further investigation. Pediatricians, who order CTs in children, must be prepared to interpret and communicate findings to families and introduce treatment in necessary situations.
Źródło:
European Journal of Clinical and Experimental Medicine; 2024, 22, 2; 275-278
2544-2406
2544-1361
Pojawia się w:
European Journal of Clinical and Experimental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of reconstructing complex multi-structural anatomical objects with RP techniques
Autorzy:
Kudasik, T.
Miechowicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/202044.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
medical modelling
rapid prototyping
computed tomography
CT
experimental tests
modelowanie medyczne
szybkie prototypowanie
tomografia komputerowa
badania doświadczalne
Opis:
This article presents reconstruction methods applied to a (geometrically and physically) complex structural object with the use of RP and RT techniques. The methods are innovative due to their hybrid - multi-model and multi-material - approach to reconstruction, as well as the application of multiple technologies. An experimental analysis was conducted to verify the feasibility of rapid prototyping (RP) techniques in the reconstruction of complex internal structures using materials of diverse properties. Some RP techniques offer the possibility of discriminating between diverse objects through the use of different colours. Such models are well-suited for diagnostic purposes, for better visualisation of complex clinical problems, pathological alterations, etc. Nevertheless, they fail to fully reflect physical and mechanical properties of objects, which renders them useful in experimental analysis only to a limited extent. Their basic drawback is that they merely reflect geometrical features of the examined object. The methods discussed in the present article enable modelling multi-object structures in a single process based on the PolyJet Matrix technology and materials of different physical properties by means of a hybrid method. The article also describes the process of modelling complex anatomical structures of soft tissues and bones using models of the maxilla and the mandible as examples. The study is based on data acquired through standard computed tomography (CT). In addition, the article addresses selected aspects of CT acquisition, generation of numerical models composed of several anatomical structures (objects) and fabricating physical multi-object models.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 2; 315-323
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies