Tytuł:
Electric Versus Hydraulic Hospital Beds: Differences in Use During Basic Nursing Tasks
Autorzy:
Capodaglio, E. M.
Powiązania:
https://bibliotekanauki.pl/articles/90572.pdf
Data publikacji:
2013
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
electric hospital bed
nursing tasks
biomechanical load
elektryczne łóżko szpitalne
obciążenia biomechaniczne
personel pielęgniarski
Opis:
Biomechanical, postural and ergonomic aspects during real patient-assisting tasks performed by nurses using an electric versus a hydraulic hospital bed were observed. While there were no differences in the flexed postures the nurses adopted, longer performance times were recorded when electric beds were used. Subjective effort, force exertion and lumbar shear forces exceeding safety limits proved electric beds were superior. Patients’ dependency level seemed to influence the type of nurses’ intervention (duration and force actions), irrespective of the bed used. The nurses greatly appreciated the electric bed. Its use seemed to reduce the level of effort perceived during care giving and the postural load during critical subtasks. Ergonomics and organizational problems related to adopting electric beds in hospital wards should be addressed further to make their use more efficient.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2013, 19, 4; 597-606
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metodyka oceny jednoczesnego oddziaływania czynników elektromagnetycznych i biomechanicznych na pracowników obsługujących podwieszane zgrzewarki rezystancyjne
Methodology for combined assessment of electromagnetic and biomechanical factors affecting workers operating suspended gun for resistance welding
Autorzy:
Zradziński, P.
Roman-Liu, D.
Powiązania:
https://bibliotekanauki.pl/articles/261280.pdf
Data publikacji:
2009
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
pole elektromagnetyczne
zgrzewarki rezystancyjne
symulacje numeryczne
obciążenie układu mięśniowo-szkieletowego
ocena ryzyka
electromagnetic fields
resistance welders
numerical calculations
musculoskeletal system load
risk assessment
Opis:
Przedstawiono problematykę związaną z jednoczesnym narażeniem pracowników obsługujących rezystancyjne zgrzewarki podwieszane na czynniki elektromagnetyczne i biomechaniczne. Omówiono metodykę oceny narażenia na pola elektromagnetyczne z wykorzystaniem symulacji numerycznych do analizy wartości gęstości prądu indukowanego oraz obciążenia biomechanicznego kręgosłupa i kończyn górnych, a także ich łącznej oceny w oparciu o wskaźnik łącznego ryzyka R.
The problems of combined electromagnetic and biomechanical risk factors affecting workers operating suspended gun for resistance welding, are discussed in this paper. Methodology for electromagnetic risk assessment using numerical calculations of induced current density and for evaluation of biomechanical load of spine and upper limbs, is proposed. The special risk index RI was introduced, which defines the risk resulted from both – electromagnetic exposure, as well as biomechanical loading.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2009, 15, 4; 399-403
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomechanical and fluid flowing characteristics of intervertebral disc of lumbar spine predicted by poroelastic finite element method
Autorzy:
Guo, L.-X
Li, R.
Zhang, M.
Powiązania:
https://bibliotekanauki.pl/articles/307246.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
kręgosłup lędźwiowy
poroelastyczność
FEM
lumbar spine
poroelastic finite element model
intermittent compressive load
permeability of cartilage endplate
Opis:
Purpose: This study is to reveal the deformation of intervertebral disc (IVD), the stress distribution of solid phase and liquid phase, the variation of fluid flux and flow velocity in lumbar spine and the influence of different permeability parameters on them under intermittent compressive loading. Methods: A poroelastic FEM of L4-L5 is assigned with different permeability parameters to analyze the deformation, stress distribution and fluid convection under intermittent compressive loads. Results: The results show that the pore pressure of IVD decreases with time, but the effective stress increases under intermittent compressive loads. The axial and radial strain will increase and fluid loss will recover at a more rapid rate if the permeability of endplate increases during unloading period. The velocity vectors show that most of the liquid in the disc flows into vertebrae through endplates and only a small quantity of liquid flows through the annulus fibrosus at the loading step, however, at the unloading step, almost all the liquid flowing into IVD is through the endplates. Conclusions: The changing rate of pore pressure and effective stresses of nucleus pulposus and annulus fibrosus with higher permeability is smaller than that with smaller permeability. The degenerated endplate (with low permeability) yields high flow velocity decreasing gradient, which might impede liquid inflowing/outflowing smoothly through the endplates. The fluid flowing velocity in loading phase is faster than that in unloading phase, so a short resting time can relieve fatigue, but could not recover to the original liquid condition in IVDs.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 2; 19-29
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of landing mat composition on ankle injury risk during a gymnastic landing: a biomechanical quantification
Autorzy:
Xiao, X.
Xiao, W.
Li, X.
Wan, B.
Shan, G.
Powiązania:
https://bibliotekanauki.pl/articles/306922.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
symulacja komputerowa
właściwości mechaniczne
sztywność
tarcie
computer simulation
impact load
mechanical properties of floor mats
stiffness
dampness
friction
Opis:
Purpose: About 70% injury of gymnasts happened during landing – an interaction between gymnast and landing mat. The most injured joint is the ankle. The current study examined the effect of mechanical properties of landing mat on ankle loading with aims to identify means of decreasing the risk of ankle injury. Method: Gymnastic skill – salto backward stretched with 3/2 twist was captured by two high-speed camcorders and digitized by using SIMI-Motion software. A subject-specific, 14-segment rigid-body model and a mechanical landing-mat model were built using BRG.LifeMODTM. The landings were simulated with varied landing-mat mechanical properties (i.e., stiffness, dampness and friction coefficients). Result: Real landing performance could be accurately reproduced by the model. The simulations revealed that the ankle angle was relatively sensitive to stiffness and dampness of the landing mat, the ankle loading rate increased 26% when the stiffness was increased by 30%, and the changing of dampness had notable effect on horizontal ground reaction force and foot velocity. Further, the peak joint-reaction force and joint torque were more sensitive to friction than to stiffness and dampness of landing mat. Finally, ankle muscles would dissipate about twice energy (189%) when the friction was increased by 30%. Conclusion: Loads to ankles during landing would increase as the stiffness and dampness of the landing mat increase. Yet, increasing friction would cause a substantial rise of the ankle internal loads. As such, the friction should be a key factor influencing the risk of injury. Unfortunately, this key factor has rarely attracted attention in practice.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 1; 105-113
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania biomechaniczne tchawicy w warunkach wielokierunkowego obciążenia
Biomechanical testing of trachea in a multidirectional load state
Autorzy:
Maksymczak, Natalia
Dudek, Arkadiusz
Noszczyk-Nowak, Agnieszka
Mackiewicz, Agnieszka
Będziński, Romuald
Powiązania:
https://bibliotekanauki.pl/articles/2201487.pdf
Data publikacji:
2019
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
tchawica
właściwości mechaniczne
model matematyczny
model hipersprężysty Mooney-Rivlin
intubacja
trachea
mechanical properties
mathematical model
Mooney-Rivlin hyperelastic model
intubation
Opis:
Uszkodzenia tchawicy spowodowane wprowadzeniem rur umożliwiających przywrócenie wentylacji płuc. Identyfikacja parametrów mechanicznych jest konieczna w celu rozpoznania patomechanizmu zmian w tkance, związanych z nieprawidłową przebudową. Uzyskane rezultaty badań mechanicznych pozwoliły na opracowanie modelu matematycznego tchawicy w warunkach wielokierunkowego obciążenia. Umożliwi to przewidywanie nadmiernych lokalnych zaburzeń pól odkształceń i naprężeń tchawicy, występujących podczas wprowadzenia rurki intubacyjnej, które do tej pory nie zostały jeszcze dokładnie zbadane.
Tracheal injury caused by the introduction of tubes to restore lung ventilation. Identification of mechanical parameters is necessary in order to identify changes in the pathomechanism of tissue associated with abnormal remodeling. The results of mechanical tests allowed us to develop a mathematical model of the trachea in a multidirectional load conditions. This will allow prediction of excessive local disturbances of the fields of strain and stress in the trachea wall occurring during the insertion of the tracheal tube, which so far have not yet been thoroughly investigated.
Źródło:
Aktualne Problemy Biomechaniki; 2019, 17; 51--57
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies