Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "atmospheric pollutant" wg kryterium: Wszystkie pola


Wyświetlanie 1-14 z 14
Tytuł:
Spatial Variation of Air Quality in Mpape Area of Abuja, Nigeria
Autorzy:
Ekoh, Harrison Charles
Powiązania:
https://bibliotekanauki.pl/articles/1031920.pdf
Data publikacji:
2020
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Atmospheric Pollutant
Mpape Area of Abuja
Particulate Matters
Variables
Opis:
The study assessed air quality along selected area of interest in Mpape Area of the FCT, Nigeria. Particularly, it examined air quality variation in the heavily built areas, industrial areas, and control sites areas in Mpape. The experimental research was employed and air quality variables such as NH3, NO2, SO2, H2S CO2 and PM10 and PM25 were quantitatively gathered in the field using standard methods and equipments such as Minivol Portable Air Sampler, A set of Crow Can Dictator Meter, and GPS. Traffic volume along selected land uses in the three locations was obtained through traffic count approach. Data obtained were analyzed using averages, ANOVA, Pearson’s correlation, cluster analysis and Factor analysis. Across the studied locations, high content of carbon monoxide (CO2) was recorded in Arab Quarry District followed by Millennium Avenue and with mean values of 1.76 ppm and 1.50ppm respectively, while in the lowest concentration of CO2 was recorded in the Control site with a mean value of 1.18ppm. The range of SO2 in the present study is above FEPA recommended level of 0.10ppm. The range is also within WHO’s 24hrs allowable limit of 20ppm, the concentration of nitrogen dioxide (NO2) varied significantly among the different locations (F = 30.540, p<0.05). The concentration of ammonia (NH3) is ranged from 0.04 to 0.06ppm. The contents of atmospheric particulate matters (PM), PM2.5 and PM10 also varied among the selected locations. For PM2.5, it value ranged from 0.18 to 0.27μg/m3 which is slightly above the threshold of 0.25μg/m3 recommended by FEPA, mostly for ambient air quality in Angwan Gwari and Millennium Avenue areas. The range of PM2.5 is within WHO’s limit of 20μg/m3 for 24hrs mean concentration. Result of ANOVA showed that the concentration of PM2.5 varied significantly among the various locations (F = 10.758 p<0.05). Furthermore, for PM10, it value ranged from 0.16 to 0.26μg/m3 which is also slightly above the threshold of 0.25μg/m3 recommended by FEPA, mostly in Arab Quarry District and to some extent Angwan Gwari/ Millennium Avenue. These areas have increased concentrations of PM10. The range of PM10 reported in the present study is within WHO’s limit of 24hrs mean concentration of 50μg/m3. Also, result of ANOVA showed that the concentration of PM10 varied significantly among the various locations (F = 9.880 p<0.05). The result therefore means that Arab Quarry District and Angwan Gwari/ Millennium Avenue have high PM10 and PM2.5 concentrations. Cluster analysis classifies the principal pollutants of Mpape into two homogenous groups (SO2 and PM, and NO2) and also identifies anthropogenic activities (principally the combustion of fuel) as the primary source of emission of these groups of gases or pollutants into the atmosphere. Factor Analysis identified anthropogenic activities as the main sources of pollution of PM, NO2, SO2, NO and CO2 in Mpape environs. From the result of this research, there should be regular monitoring of atmospheric pollutants around the area in order to prevent the potential health and atmospheric related impacts of such air toxics in the region; Government should assist in the development of these new technologies that will enhance engine efficiency and reduce fuel consumption through the funding of research.
Źródło:
World Scientific News; 2020, 140; 79-112
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of fertilization on the content of some aluminium fractions in acidic soils
Autorzy:
Filipek, T.
Badora, A.
Dechnik, I.
Powiązania:
https://bibliotekanauki.pl/articles/796966.pdf
Data publikacji:
1998
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
fertilization
aluminium content
aluminium fraction
acid soil
soil
atmospheric pollutant
potassium fertilization
nitrogen fertilization
Opis:
The present studies were carried out on the basis of field experiment on the strongly acidic soil (pH 3.9). The following treatments were applied: liming, fertilization with manure and nitrogen in the form of ammonium (NH₄)₂SO₄ and nitrate Ca(NO₃)₂ forms of nitrogen, as well as sulphate K₂SO₄ and chloride KCl potassium fertilizers. Liming (CaCO₃) eliminated the effect of aluminium mobilization by (NH₄)₂SO₄. Calcium nitrate Ca(NO₃)₂ and potassium salt KCl limited the content of aluminium strongly bound to the soil organic matter.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 1998, 456
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natural variation in ozone induced cell death in Arabidopsis
Autorzy:
Leppala, J.
Brosche, M.
Powiązania:
https://bibliotekanauki.pl/articles/80797.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
conference
natural variation
atmospheric pollutant
ozone
reactive oxygen species
programmed cell death
molecular response
Arabidopsis thaliana
quantitative trait locus
Źródło:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology; 2013, 94, 2
0860-7796
Pojawia się w:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zapylenie powietrza atmosferycznego na głównych szlakach komunikacyjnych m. st. Warszawy
Zapylenie atmosfernogo vozdukha na glavnykh putjakh soobshhenija v Varshave
Atmospheric air pollution on highways of Warsaw
Autorzy:
Zwolinski, J.
Wyszynska, H.
Misiakiewicz, Z.
Kosinski, K.
Powiązania:
https://bibliotekanauki.pl/articles/873042.pdf
Data publikacji:
1963
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
zanieczyszczenia atmosfery
ruch uliczny
miasta
szlaki komunikacyjne
zapylenie atmosfery
stopien zapylenia
Warszawa
atmospheric pollutant
traffic
town
transport route
atmospheric dust
dustiness
Warsaw area
Źródło:
Roczniki Państwowego Zakładu Higieny; 1963, 14, 2
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air pollution and hydromorphological description of the river
Autorzy:
Cichowicz, Robert
Michalska, Barbara
Powiązania:
https://bibliotekanauki.pl/articles/1178424.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
RHS
atmospheric air
hydromorphological status
pollutant emissions
Opis:
Hydromorphological assessment of surface water status not only takes into account biological and physicochemical components, but also structural characteristics of surface waters including among others: hydrological regime, river continuity and morphological conditions. It should be borne in mind that the quality of surface water is also influenced by atmospheric conditions and the type of pollution that occurs in the areas surrounding the catchment area. Because harmful substances can get into the tanks both as a result of precipitation that can absorb atmospheric pollutants and by leaching from neighboring areas of solid contaminants there. It is therefore important to conduct surface water analysis in conjunction with air quality monitoring.
Źródło:
World Scientific News; 2017, 73; 80-91
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Atmospheric self-cleaning coefficients as indicators of the atmospheric ability to dissipate pollutants in Ukraine
Autorzy:
Malytska, L.
Balabukh, V.
Powiązania:
https://bibliotekanauki.pl/articles/108486.pdf
Data publikacji:
2018
Wydawca:
Instytut Meteorologii i Gospodarki Wodnej - Państwowy Instytut Badawczy
Tematy:
jakość powietrza
odprowadzanie
zanieczyszczenie
współczynnik samooczyszczania
zintegrowany indeks meteorologiczny
air quality
pollutant dissipation ability
self-cleaning coefficient
integrated meteorological index
Opis:
Air quality is determined by the level of air pollution, which depends on the concentration of pollutants and meteorological conditions conducive to their transport, dispersion and washout from the atmosphere. If emission variety is poor, the pollution level depends only on meteorological conditions. This article considers the atmospheric ability to dissipate pollutants in Ukraine, and the various features of this ability in different regions, through the comparative analysis of modifications of the atmosphere’s self-cleaning index – the special mathematical formulas that formalize the influence of basic meteorological parameters on the content of impurities in the air. In Ukraine, in accordance with the atmosphere self-cleaning coefficient (K), meteorological conditions mostly lead to the dissipation of contaminants. But there are also allocated buffer zones, where meteorological conditions are favourable to a limited extent; it is very likely these areas will increase due to climate change. Based on analysis of the improved integrated meteorological index (UMPA), all territory of the country has steadily favourable conditions for the dissipation of pollutants, without limitedly favourable areas. The component analysis, however, showed that it is fully true only for the thermal component. Analysis of precipitation and wind coefficients has shown that the steppe zone has a sufficient, but unstable wetting, which ensures only partial opportunities for the atmosphere’s self-cleaning and only a small part of Ukraine has good airing conditions. Taking into account the fact that results are not consistent and that the UMPA was developed for physical and geographical conditions of the north of the Russian Federation, we propose priority actions for adapting it for Ukraine.
Źródło:
Meteorology Hydrology and Water Management. Research and Operational Applications; 2018, 6, 1; 59-65
2299-3835
2353-5652
Pojawia się w:
Meteorology Hydrology and Water Management. Research and Operational Applications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of longitudinal slope of main road carriage-way on the mass emission from road transport in the atmospheric air
Vlijanie prodol'nogo uklona proezzhejj chasti magistrali na massu vybrosov ot avtomobil'nogo transporta v atmosferu
Autorzy:
Solukha, I.
Powiązania:
https://bibliotekanauki.pl/articles/77494.pdf
Data publikacji:
2015
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
longitudinal slope
public main road
mass emission
pollutant
motor transport
road transport
atmospheric air
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2015, 17, 8
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zanieczyszczenie powietrza atmosferycznego w Opolu pyłem mineralnym w okresie od czerwca 1960 r. do maja 1961 r.
Autorzy:
Hochul, M.
Powiązania:
https://bibliotekanauki.pl/articles/871961.pdf
Data publikacji:
1962
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
powietrze atmosferyczne
zanieczyszczenia powietrza
zanieczyszczenia mineralne
pyly
pyly cementowe
zapylenie atmosfery
cementownie
Opole
strefy zanieczyszczen
stopien zanieczyszczenia
atmospheric air
air contaminant
mineral pollutant
dust
ceramic dust
atmospheric dust
cement factory
Opole region
pollution zone
pollution degree
Źródło:
Roczniki Państwowego Zakładu Higieny; 1962, 13, 4
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oznaczenie kwasu siarkowego w powietrzu atmosferycznym przy jednoczesnym występowaniu siarczanu amonowego
Determination of sulphuric acid in atmospheric air containing ammonium sulphate as another pollutant
Autorzy:
Pines, I.
Powiązania:
https://bibliotekanauki.pl/articles/877847.pdf
Data publikacji:
1979
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
zanieczyszczenia powietrza
powietrze atmosferyczne
siarczan amonu
kwas siarkowy
oznaczanie
oznaczanie zawartosci
metoda oznaczania
Źródło:
Roczniki Państwowego Zakładu Higieny; 1979, 30, 4
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zanieczyszczenie powietrza atmosferycznego dwusiarczkiem węgla i siarkowodorem wokół fabryki sztucznego jedwabiu
Zagrjaznenie atmosfernogo vozdukha serouglerodom i serovodorodom vokrug zavoda isskistvennogo shelka
Carbon disulphide and hydrogen sulphide atmospheric air contamination around a factory of artificial silk
Autorzy:
Dutkiewicz, T.
Kesy, I.
Piotrowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/875059.pdf
Data publikacji:
1958
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
zanieczyszczenia powietrza
dwusiarczek wegla
siarkowodor
uprzemyslowienie
stan srodowiska
powietrze atmosferyczne
czystosc powietrza
stezenie zanieczyszczen
oznaczanie
Tomaszow Mazowiecki
air contaminant
carbon disulphide
hydrogen sulphide
industrialization
environment state
atmospheric air
air quality
pollutant concentration
determination
Tomaszow Mazowiecki town
Źródło:
Roczniki Państwowego Zakładu Higieny; 1958, 09, 6
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of relationship between air pollutant concentration and meteorological elements in winter months
Ocena zależności między wielkością stężenia zanieczyszczeń powietrza a elementami meteorologicznymi w okresie zimowym
Autorzy:
Żyromski, A.
Biniak-Pieróg, M.
Burszta-Adamiak, E.
Zamiar, Z.
Powiązania:
https://bibliotekanauki.pl/articles/293219.pdf
Data publikacji:
2014
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
atmospheric pollutants
meteorological parameters
stepwise regression
winter season
elementy meteorologiczne
okres zimowy
regresja krokowa
temperatura
zanieczyszczenie powietrza
Opis:
The paper presents the evaluation of the relation between meteorological elements and air pollutants’ concentrations. The analysis includes daily concentrations of pollutants and variation of meteorological elements such as wind speed, air temperature and relative humidity, precipitation and total radiation at four monitoring stations located in the province of Lower Silesia in individual months of the winter half-year (November–April, according to hydrological year classification) of 2005–2009. Data on air quality and meteorological elements came from the results of research conducted in the automatic net of air pollution monitoring conducted in the range of the State Environment Monitoring. The effect of meteorological elements on analysed pollutant concentration was determined using the correlation and regression analysis at significance level α < 0.05. The occurrence of maximum concentration of NO, NO2, NOX, SO2 and PM10 occurred in the coldest months during winter season (January, February and December) confirmed the strong influence of “low emission” on air quality. Among the meteorological factors assessed wind speed was most often selected component in step wise regression procedure, then air temperature, less air relative humidity and solar radiation. In the case of a larger number of variables describing the pollution in the atmosphere, in all analyzed winter seasons the most common set of meteorological elements were wind speed and air temperature.
W pracy przedstawiono wyniki badań mające na celu ocenę związków między stężeniem zanieczyszczeń powietrza a elementami meteorologicznymi. Analizą objęto średniodobowe wartości emisji zanieczyszczeń gazowych i pyłowych oraz wybrane elementy meteorologiczne, tj. prędkość wiatru, temperaturę, wysokość opadu atmosferycznego, wilgotność względną oraz promieniowanie całkowite na czterech stacjach pomiarowych zlokalizowanych na terenie województwa dolnośląskiego w okresie zimowym (listopad–kwiecień, zgodnie z klasyfikacją roku hydrologicznego) dla lat 2005– 2009. Dane te pochodziły z badań z automatycznych sieci monitoringu zanieczyszczeń powietrza prowadzonych w ramach Państwowego Monitoringu Środowiska. Wpływ elementów meteorologicznych na stężenie analizowanych zanieczyszczeń określono z zastosowaniem analizy korelacji oraz regresji krokowej na poziomie istotności α < 0,05. Występowanie maksymalnych wartości stężenia NO, NO2, NOX oraz SO2 w najchłodniejszych miesiącach okresu zimowego (styczeń, luty i grudzień) potwierdziło duży wpływ „małej emisji” na jakość powietrza. Elementami meteorologicznymi najczęściej wskazywanymi w opisach zależności i za pomocą procedury regresji krokowej były prędkość wiatru, następnie temperatura powietrza i rzadziej wilgotność względna powietrza, temperatura powietrza, promieniowanie całkowite oraz wilgotność powietrza. W przypadku występowania większej ilości zmiennych opisujących zanieczyszczenia w atmosferze, we wszystkich analizowanych półroczach zimowych najczęściej występującym układem elementów meteorologicznych była prędkość wiatru i temperatura powietrza.
Źródło:
Journal of Water and Land Development; 2014, 22; 25-32
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of the Municipal Solid Waste Incineration Plant in Warsaw on Air Quality
Wpływ spalarni odpadów komunalnych w Warszawie na jakość powietrza
Autorzy:
Oleniacz, R.
Powiązania:
https://bibliotekanauki.pl/articles/385952.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
odpady komunalne
spalanie
spalarnia odpadów
piec rusztowy
emisja zanieczyszczeń
ocena oddziaływania
jakość powietrza
modelowanie dyspersji w atmosferze
municipal solid waste
incineration
MSWI
full-scale incinerator
grate furnace
air pollutant emission
air quality
impact assessment
atmospheric dispersion modeling
Opis:
Jedyna polska spalarnia odpadów komunalnych jest eksploatowana na terenie Zakładu Unieszkodliwiania Stałych Odpadów Komunalnych (ZUSOK) w Warszawie od roku 2000. W pracy przedstawiono wybrane wyniki oceny wpływu tej spalarni na jakość powietrza w jednorocznym okresie jej funkcjonowania (rok 2008), który można uznać za typowy dla tego zakładu pod względem ilości spalanych odpadów i emisji substancji zanieczyszczających. Ocena jej oddziaływania na jakość powietrza opiera się na porównaniu poziomów emisji zanieczyszczeń do powietrza z odpowiednimi standardami emisyjnymi i modelowaniu dyspersji wybranych substancji w powietrzu atmosferycznym. Wykazano, że spalarnia odpadów komunalnych w Warszawie jest mało istotnym źródłem zanieczyszczeń emitowanych do powietrza i powoduje nieznaczne jego zanieczyszczenie w zasięgu swojego oddziaływania. Planowana w następnych latach rozbudowa tej spalarni powodująca kilkukrotne zwiększenie jej zdolności przerobowej przy dalszym dotrzymywaniu standardów emisyjnych również nie powinna spowodować istotnego pogorszenia jakości powietrza atmosferycznego.
The only Polish municipal solid waste (MSW) incinerator has been operating within the Municipal Solid Waste Disposal Plant in Warsaw since 2000. In the paper selected results of the air quality impact assessment for this incinerator during an operating period of one year (2008) are presented. With respect to the incinerated waste amounts and emission levels, the analysed period can be considered typical for this facility. Assessment of the air quality impact was carried out by assessing air pollutant emissions in reference to the applicable emission limit values and by modeling atmospheric dispersion of these pollutants. It has been found that the MSW incineration plant in Warsaw is an insignificant air pollutant source and causes slight air pollution within its impact range. Pollutant concentrations caused in the atmosphere are many times lower than the permissible substance levels and reference values valid for a given substance. Planned as a result of the expansion of the incineration plant, the increase in its processing capacity while continuing to meet the emission standards should also not cause a significant impact on air quality.
Źródło:
Geomatics and Environmental Engineering; 2014, 8, 4; 25-42
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of Optimal Spatial Databases for the area of Poland to the Calculation of Air Pollutant Dispersion Using the CALMET / CALPUFF Model
Określenie optymalnych baz danych przestrzennych dla obszaru Polski na potrzeby obliczeń rozprzestrzeniania się zanieczyszczeń w powietrzu atmosferycznym z zastosowaniem modeli CALMET / CALPUFF
Autorzy:
Oleniacz, R
Rzeszutek, M.
Powiązania:
https://bibliotekanauki.pl/articles/385404.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
air pollution
atmospheric dispersion models
CALMET
CALPUFF
spatial database
SRTM3
GTOPO30
CLC
GLCC
zanieczyszczenie powietrza
model dyspersji atmosferycznej
bazy danych przestrzennych
SRTM-3
Opis:
This paper presents a methodology for the preparation of three-dimensional spatial data and land use data for the purpose of modeling pollutant dispersion in the ambient air using a group of geophysical preprocessors of the CALMET / CALPUFF modeling system and the GIS software. Some space information data sources available to Poland were specified and their characteristics and availability were discussed. Particular attention was turned to the SRTM3 and GTOPO30 elevation data as well as the CLC2006 and GLCC land use data, for the preparation of computational grids of different resolutions. Groups of programs which can be used in order to form computational grids based on the above-mentioned databases were identified. The discussed spatial data preparation procedure was used for the area of the city of Krakow and the surrounding area. As a result of the conducted activities, processed information on the terrain in the adopted computational area, possible to be used in the calculation of a three-dimensional meteorological grid (CALMET) and in the calculation of pollutant dispersion in the ambient air (CALPUFF) was obtained.
W pracy przedstawiono metodykę przygotowania trójwymiarowych danych przestrzennych i użytkowania terenu na potrzeby modelowania rozprzestrzenia się zanieczyszczeń w powietrzu atmosferycznym z zastosowaniem grupy preprocesorów geofizycznych systemu modelowania CALMET / CALPUFF i oprogramowania typu GIS. Wskazano niektóre dostępne dla terenu Polski źródła danych informacji o przestrzeni oraz omówiono ich charakterystykę i dostępność. Szczególną uwagę zwrócono na dane wysokościowe SRTM3 i GTOPO30 oraz dane użytkowania terenu CLC2006 i GLCC pod kątem przygotowania siatek obliczeniowych o różnej rozdzielczości. Wskazano grupy programów możliwych do zastosowania w celu utworzenia siatek obliczeniowych w oparciu o wyżej wymienione bazy danych. Omówiony sposób przygotowania danych przestrzennych został zastosowany dla obszaru miasta Krakowa i okolic. W efekcie przeprowadzonych działań uzyskano przetworzoną informację o terenie w przyjętym obszarze obliczeniowym możliwą do wykorzystania w obliczeniach trójwymiarowej siatki meteorologicznej (CALMET) oraz w obliczeniach rozprzestrzenia się zanieczyszczeń w powietrzu atmosferycznym (CALPUFF).
Źródło:
Geomatics and Environmental Engineering; 2014, 8, 2; 57-69
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air quality influence of selected pollutants emitted from a fire of 300 Mg of municipal waste on ambient air quality: an example of modelling with HYSPLIT
Wpływ wybranych zanieczyszczeń powietrza wyemitowanych w pożarze 300 Mg odpadów na jakość powietrza atmosferycznego – przykład wykorzystania HYSPLIT
Autorzy:
Rogula-Kozłowska, Wioletta
Bihałowicz, Jan Stefan
Powiązania:
https://bibliotekanauki.pl/articles/24202649.pdf
Data publikacji:
2022
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
waste fire
environmental impact
exposure to pollutant
atmospheric dispersion
HYSPLIT
fire risk
rescue management
pożary odpadów
oddziaływanie na środowisko
ekspozycja na zanieczyszczenia
rozprzestrzenianie atmosferyczne
ryzyko pożarowe
zarządzanie akcją ratowniczą
Opis:
Reducing the amount of waste disposed of in landfills requires treatment in specialised facilities. Potential threats that can arise both in waste processing and in its storage comprise a fire hazard. Waste fires hold a significant share of the total number of the largest fires in Poland. Fires in landfills and their treatment facilities are related to air quality since during a fire a large number of various pollutants is emitted into the atmosphere in a relatively short time. The paper discusses the impact of a fire taking place at a waste treatment facility on air quality, in which 300 Mg of municipal waste was burnt. Using the HYSPLIT package, the atmospheric dispersion of 23 selected organic and inorganic pollutants was determined and then analysed in GIS software. The concentrations were compared with reference values specified in relevant legal regulations. Of the 23 substances analyzed, the concentration levels were exceeded only for 6 substances at a distance of more than half a kilometre from the fire: benzo(a)pyrene, benzene, styrene, acetaldehyde, PM10, and NO2 . The substance with the greatest range as regards the reference concentration levels was benzo(a)pyrene, a compound with a proven carcinogenic effect, which indicates the importance of reducing landfill fires in the context of public health.
Zmniejszenie ilości odpadów składowanych na wysypiskach wymaga ich przetwarzania w wyspecjalizowanych zakładach. Wśród zagrożeń, które pojawiają się zarówno w przetwarzaniu odpadów, jak i ich składowaniu, znajduje się zagrożenie pożarowe. Pożary odpadów mają znaczący udział w ogólnej liczbie największych pożarów w Polsce. Podczas pożaru duża liczba różnych zanieczyszczeń jest emitowana do atmosfery w stosunkowo krótkim czasie, w związku z czym pożary odpadów są związane z jakością powietrza atmosferycznego. W pracy omówiono wpływ pożaru w zakładzie przetwarzania odpadów na jakość powietrza, w którym spłonęło 300 Mg odpadów komunalnych. Przy wykorzystaniu pakietu HYSPLIT wyznaczono dyspersję atmosferyczną 23 wybranych zanieczyszczeń organicznych i nieorganicznych, a następnie przeanalizowano ją w oprogramowaniu GIS. Stężenia porównano z wartościami referencyjnymi określonymi w odpowiednich aktach prawnych. Spośród 23 analizowanych substancji poziomy odniesienia zostały przekroczone tylko dla 6 substancji w odległości ponad pół kilometra od ognia: benzo(a)pirenu, benzenu, styrenu, aldehydu octowego, PM10 i NO2 . Substancją o największym zakresie, jeśli chodzi o poziomy stężeń referencyjnych, był benzo(a)piren, związek o udowodnionym działaniu rakotwórczym, co wskazuje na znaczenie ograniczenia pożarów składowisk w kontekście zdrowia publicznego.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2022, 83; 33--43
0239-5223
2720-0779
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies