Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "apnea screening" wg kryterium: Wszystkie pola


Wyświetlanie 1-7 z 7
Tytuł:
Authors’ response (November 28, 2017) to the letter to the Editor concerning the paper “Screening commercial drivers for obstructive sleep apnea: Validation of STOP-Bang questionnaire”
Autorzy:
Popević, Martin B.
Milovanović, Andjela
Nagorni-Obradović, Ljudmila
Nešić, Dejan
Milovanović, Jovica
Milovanović, Aleksandar P.
Powiązania:
https://bibliotekanauki.pl/articles/2162021.pdf
Data publikacji:
2018-10-24
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
sleep apnea
questionnaires
polysomnography
obstructive
validation studies
commercial drivers
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2018, 31, 5; 699-701
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka przesiewowa zaburzeń oddychania podczas snu u chorych z kardiomiopatią rozstrzeniową
Screening evaluation of breathing disorders during sleep in patients with dilated cardiomyopathy
Autorzy:
Ścierski, Wojciech
Dola, Janusz
Maksym-Kulas, Beata
Krzemień-Wolska, Krystyna
Brzostowicz, Tomasz
Kawecka, Izabela
Kawecki, Damian
Powiązania:
https://bibliotekanauki.pl/articles/1037795.pdf
Data publikacji:
2014
Wydawca:
Śląski Uniwersytet Medyczny w Katowicach
Tematy:
zespół obturacyjnych bezdechów sennych
kardiomiopatia rozstrzeniowa
nadmierna senność dzienna
skala epworth
obstructive sleep apnea syndrome
dilated cardiomyopathy
daytime somnolence
epworth scale
Opis:
BACKGROUND The findings of many studies on obstructive sleep apnea syndrome (OSA) indicate a relationship between OSA and cardiovascular diseases. The aim of the study was to evaluate the risk of breathing disorders in patients suffering from dilated cardiomyopathy. MATERIAL AND METHODS The study group comprised 51 patients with diagnosed dilated cardiomyopathy. The screening evaluation contains medical history data (snoring, excessive daytime somnolence), physical examination of laryngeal organs, BMI index and daytime somnolence Epworth scale. RESULTS Permanently or intemittently appearing snoring during sleep occurred in 30 patients. Three patients complained of daytime somnolence. In 22 cases during laryngological examination of the airways, patency disorders were found. Evaluation of the Epworth scale daytime somnolence showed results ranging from 0 to 12 with the average of 2.9 ± 2.5. The BMI index for all the patients was 26.59 ± 4.48. CONCLUSIONS The results of our study showed that in spite of the upper airway anatomical abnormalities in 22 patients coexisting with snoring during sleep (suggested OSA syndrome), no pathological daytime somnolence in the Epworth scale examination was found.
W S T Ę P Wyniki wielu badań nad zespołem obturacyjnych bezdechów sennych wskazują na związek między tym schorzeniem a chorobami układu krążenia. Celem pracy była przesiewowa ocena ryzyka występowania zaburzeń oddychania podczas snu u chorych ze zdiagnozowaną kardiomiopatią rozstrzeniową. M A T E R I A Ł I M E T O D Y Zbadano grupę 51 chorych z rozpoznaną kardiomiopatią rozstrzeniową. Badania przesiewowe obejmowały dane zebrane z wywiadu (chrapanie, nadmierna senność w ciągu dnia), ocenę narządów laryngologicznych, ocenę senności dziennej skalą Epworth, wskaźnik BMI. WYNIKI Stałe lub okresowo pojawiające się chrapanie w czasie snu, które w istotny sposób zakłócało ciszę nocną występowało u 30 chorych. Objawy nadmiernej senności w ciągu dnia zgłaszało 3 chorych. W badaniu laryngologicznym u 22 chorych stwierdzono zaburzenia drożności w obrębie górnych dróg oddechowych. Badanie stopnia senności dziennej wykazało, iż wskaźnik Epworth wynosił od 0 do 12, średnio dla całej grupy 2,9 ± 2,5. Wskaźnik BMI dla całej grupy chorych wynosił 26,59 ± 4,48. WNIOSKI Mimo występowania u 22 chorych zaburzeń anatomicznych w obrębie górnych dróg oddechowych oraz objawów sugerujących zespół bezdechów sennych (chrapanie), nie stwierdziliśmy w badanej grupie patologicznej senności dziennej ocenianej skalą Epworth.
Źródło:
Annales Academiae Medicae Silesiensis; 2014, 68, 4; 241-244
1734-025X
Pojawia się w:
Annales Academiae Medicae Silesiensis
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Letter to the Editor (November 15, 2017) concerning the paper “Screening commercial drivers for obstructive sleep apnea: Validation of STOP-Bang questionnaire”
Autorzy:
Kawada, Tomoyuki
Powiązania:
https://bibliotekanauki.pl/articles/2162020.pdf
Data publikacji:
2018-10-24
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
obstructive sleep apnea
questionnaire
validity
STOP-Bang
commercial drivers
screening
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2018, 31, 5; 697-698
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parasomnias and obstructive sleep apnea syndrome: in search for a parasomnia evaluating tool appropriate for OSAS screening
Autorzy:
Wieczorek, Tomasz
Lorenc, Maciej
Martynowicz, Helena
Piotrowski, Patryk
Mazur, Grzegorz
Rymaszewska, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/551574.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Przyjaciół Medycyny Rodzinnej i Lekarzy Rodzinnych
Tematy:
parasomnias
sleep apnea syndromes
sleep apnea
obstructive.
Źródło:
Family Medicine & Primary Care Review; 2018, 2; 176-181
1734-3402
Pojawia się w:
Family Medicine & Primary Care Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability of the Epworth Sleepiness Scale and the Berlin Questionnaire for screening obstructive sleep apnea syndrome in the context of the examination of candidates for drivers
Wiarygodność Skali Senności Epworth i Kwestionariusza Berlińskiego w diagnostyce przesiewowej zespołu obturacyjnego bezdechu sennego w kontekście badań kandydatów na kierowców
Autorzy:
Kiciński, Paweł
Przybylska-Kuć, Sylwia M.
Tatara, Kalina
Dybała, Andrzej
Zakrzewski, Maciej
Myśliński, Wojciech
Mosiewicz, Jerzy
Jaroszyński, Andrzej J.
Powiązania:
https://bibliotekanauki.pl/articles/2164235.pdf
Data publikacji:
2016-12-22
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
medycyna pracy
wiarygodność
badania kierowców
zespół obturacyjnego bezdechu sennego
badania ankietowe
polisomnografia
occupational medicine
reliability
drivers’ examinations
obstructive sleep apnea syndrome
questionnaires
polysomnography
Opis:
Background The aim of the study has been to assess the usefulness of the Epworth Sleepiness Scale (ESS) and the Berlin Questionnaire (BQ) for obstructive sleep apnea syndrome (OSAS) screening. The capacity of both tests to discriminate between healthy individuals or with mild OSAS (apnea-hypopnea index (AHI) < 15/h) vs. patients with moderate or severe OSAS (AHI ≥ 15/h) was evaluated. Material and Methods The study encompassed 223 patients with a suspicion of the OSAS. The ESS and BQ were completed by patients unassisted. Screening polysomnography was performed using the Porti SleepDoc. The OSAS was diagnosed when AHI ≥ 15/h or AHI ≥ 5/h with simultaneous occurrence of clinical symptoms. Results The ESS score was found to be significantly higher in the study group compared to the control group (8.9±5.9 vs. 11.6±5.2 pt, p < 0.0001). Otherwise, there were no significant inter-group differences in the percentage of high-risk individuals according to the BQ (83.7% vs. 92.3%, p > 0.05). Sensitivity of the ESS and BQ was 53.2% and 93.1%, respectively while specificity was 58.8% and 16.2%, respectively. Poor correlation between the ESS score and AHI and apnea index were noticed (r = 0.22, p = 0.001 and r = 0.24, p < 0.001, respectively). Conclusions Considering its low sensitivity, the ESS should not be used as a screening test for the OSAS diagnosis amongst candidates for drivers. The BQ is characterised by high sensitivity for the OSAS diagnosis with AHI ≥ 15/h, however, due to low specificity, the questionnaire may increase the number of healthy individuals referred for needless diagnostic procedures. Med Pr 2016;67(6):721–728
Wstęp Celem pracy była ocena przydatności Skali Senności Epworth (SSE) i Kwestionariusza Berlińskiego (KB) w diagnostyce przesiewowej zespołu obturacyjnego bezdechu sennego (obstructive sleep apnea syndrome – OSAS). Oceniono przydatność obu testów do rozróżniania osób zdrowych od osób z łagodnym OSAS (wskaźnik bezdechu i spłyceń oddechu (apnea-hypopnea index – AHI) < 15/godz.) i pacjentów z umiarkowanym lub ciężkim OSAS (AHI ≥ 15/godz.). Materiał i metody Do badania włączono 223 pacjentów z podejrzeniem zaburzeń oddychania w czasie snu, którzy wypełnili SSE i KB. Uproszczoną polisomnografię wykonano z wykorzystaniem urządzeń Porti SleepDoc. W przypadku stwierdzenia AHI ≥ 15/godz. lub AHI ≥ 5/godz. i jednoczesnego występowania objawów klinicznych rozpoznawano OSAS. Wyniki Wynik SSE był istotnie wyższy w grupie badanej niż w grupie porównawczej (8,9±5,9 vs 11,6±5,2 pkt, p < 0,0001), natomiast odsetek osób z wysokim ryzykiem OSAS według KB nie różnił się istotnie w obu grupach (83,7% vs 92,3%, p > 0,05). Czułość SSE wyniosła 53,2%, a KB – 93,1%, natomiast swoistość SSE – 8,8%, a KB – 16,2%. Odnotowano słabą korelację między wynikiem SSE a AHI i wskaźnikiem bezdechów (odpowiednio: r = 0,22, p = 0,001 vs r = 0,24, p < 0,001). Wnioski Ze względu na niską czułość SSE nie powinna być stosowana jako samodzielny test przesiewowy w diagnostyce OSAS u kandydatów na kierowców. Natomiast KB, mimo że cechuje się dużą czułością w rozpoznawaniu umiarkowanego lub ciężkiego OSAS (AHI ≥ 15/godz.), z powodu bardzo niskiej swoistości może przyczyniać się do kierowania osób zdrowych na zbędną diagnostykę. Med. Pr. 2016;67(6):721–728
Źródło:
Medycyna Pracy; 2016, 67, 6; 721-728
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Screening commercial drivers for obstructive sleep apnea: Validation of STOP-Bang questionnaire
Autorzy:
Popević, Martin B.
Milovanović, Andjela
Nagorni-Obradović, Ljudmila
Nešić, Dejan
Milovanović, Jovica
Milovanović, Aleksandar P.
Powiązania:
https://bibliotekanauki.pl/articles/2161889.pdf
Data publikacji:
2017-07-14
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
sleep apnea
questionnaires
polysomnography
obstructive
validation studies
commercial drivers
Opis:
Objectives The main aim has been to examine psychometric properties of STOP-Bang (snoring, tiredness, observed apnea, high blood pressure, body mass index (BMI), age, neck circumference, male gender) scoring model (Serbian translation), an obstructive sleep apnea (OSA) screening tool, in a sample of commercial drivers. Material and Methods After formal translation, validation was performed on a sample of bus and truck drivers evaluating test-retest reliability, construct and criterion validity. Overnight polysomnography or cardiorespiratory polygraphy were used for OSA diagnosis purposes. Results One hundred male participants, 24–62 years old, were included. STOP-Bang classified 69% as potential OSA patients. Polysomnography identified OSA in 57% of the sample. Test-retest reliability (Cohen’s κ = 0.89) was adequate. STOP-Bang score was significantly correlated to apnea-hypopnea index (AHI) and OSA severity. Sensitivity was 100% for AHI ≥ 15, highest specificity was 53.5% (AHI ≥ 5). Conclusions STOP-Bang showed good measurement properties, supporting its further use in OSA screening of commercial drivers. Int J Occup Med Environ Health 2016;30(5):751–761
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 5; 751-761
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sieć telemetryczna do badań bezdechu
Telemetric network for apnea screening
Autorzy:
Graffstein, J.
Krawczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/213351.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
aparatura pomiarowa
sieć telemetryczna
badania bezdechu
measuring equipment
telemetric network
apnea screening
Opis:
W pracy podano główne założenia projektu rozwojowego, podejmującego próbę zbudowania sieci telemetrycznej do badań screeningowych zespołu bezdechu sennego podczas snu. W szczególności omówiono budowę i zasadę działania urządzenia diagnostycznego oraz zaprezentowano możliwość zastosowania różnych, testowanych podczas realizacji projektu czujników pomiarowych. Pokazano ogólną organizację sieci telemetrycznej, w tym GUI wraz z programem narzędziowym zapewniającymi współdziałanie hardwareowej części systemu z operatorem – lekarzem specjalistą. Kolejno przedstawiono ogólne założenia badań klinicznych, a następnie omówiono uzyskane podczas nich wyniki oraz przedstawiono wnioski.
In the article main assumptions of the telemetric network for apnea screening are presented. As a conclusion, the test trials program and some remarks about clinical test results are provided. The diagnostic method presented here and developed within the grant project, is based on indirect estimation of breathing process depending on analysis of abdomen and chest movements. The measurement is realized by piezo-electric sensor. The recorded signal is then subjected to advanced numerical analysis aimed at apnea detection. Some preliminary results of test measurements carried on in hospital are presented and discussed in the article.
Źródło:
Prace Instytutu Lotnictwa; 2010, 4 (206); 29-35
0509-6669
2300-5408
Pojawia się w:
Prace Instytutu Lotnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies