Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "X-ray method" wg kryterium: Wszystkie pola


Tytuł:
Preparation and Study of CdS thin films at different concentration thiorea by chemical bath deposition (CBD) method
Autorzy:
Anwar, H. Ali
Jassem, Sarah A.
Powiązania:
https://bibliotekanauki.pl/articles/1193882.pdf
Data publikacji:
2015
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Atomic Force Microscopy
CdS nanostructure
CdS thin films
UV-Vis
X-Ray Diffraction
XRD
chemical bath deposition
nanostructure
Opis:
CdS nanostructure are prepared by chemical bath deposition CBD method using different thiourea concentrations. The thiourea concentration effect for CdS nanostructure deposited on glasses substrate have been studied. CdS nanostructure give important analysis of X-ray diffraction (XRD), optical transmittance using (UV-Vis) spectroscopy, in addition to characterization of Atomic force microscopy (AFM) to analyze surface morphology of a film and to determine the grain size have proved a good agreement with experimental and theoretical results.
Źródło:
World Scientific News; 2015, 23; 73-89
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-Ray and Electron-Optical Characterization of ZnTe/CdTe and ZnTe/GaAs Epitaxial Layers Obtained by the MBE Method
Autorzy:
Auleytner, J.
Dziuba, Z.
Górecka, J.
Pełka, J.
Regiński, K.
Powiązania:
https://bibliotekanauki.pl/articles/1931657.pdf
Data publikacji:
1994-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.14.Hg
61.10.-i
68.55.-a
Opis:
X-ray diffraction topography (Bragg diffraction) and X-ray rocking curve measurements were used to study the perfection and structural properties of ZnTe epitaxial layers on the CdTe and GaAs substrates. ZnTe epitaxial layers on CdTe were grown by MBE method by using a machine made in the Institute of Physics of the Polish Academy of Sciences. The ZnTe layers on GaAs were produced on the other, factory-made MBE system. The comparison between the X-ray topographical images of the substrate and epitaxial layer shows that imperfections on the substrate surface cause imperfections in the epitaxial layer. The results of double-crystal diffractometry measurements show that the perfection of the layer on the GaAs substrate is higher than that on the CdTe. The presence of microtwining in the ZnTe layer on the CdTe substrate was confirmed by RHEED measurements. The X-ray standing wave fluorescent spectra were also measured for the samples.
Źródło:
Acta Physica Polonica A; 1994, 86, 4; 567-574
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania identyfikacyjne materiałów wiążących na bazie cementu
Identification tests of cement-based binders
Autorzy:
Babińska, J.
Powiązania:
https://bibliotekanauki.pl/articles/182847.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniki Budowlanej
Tematy:
materiał wiążący
cement
badanie identyfikacyjne
metoda badań
wymagania normowe
klej cementowy
analiza termiczna
XRD
binding material
identification test
test method
standard requirements
cement-based adhesive
thermal analysis
X-ray diffractometry
Opis:
Badania identyfikacyjne są kluczowe w badaniach aprobacyjnych oraz w przypadku spraw spornych dotyczących jakości materiału budowlanego. Zalicza się do nich między innymi metody instrumentalne, obejmujące takie badania jak dyfrakcja rentgenowska, badania w podczerwieni oraz analiza termiczna. Metody instrumentalne stosowane kompleksowo pozwalają na pełne odwzorowanie składu fazowego badanych próbek, natomiast stosowane pojedynczo mogą pełnić rolę fingerprintu. Wybór metod identyfikacyjnych jest ściśle uzależniony od składu badanego materiału i celu badania, co zostało pokazane na przykładzie klejów cementowych stosowanych w systemach ociepleń.
Identification tests depending on the type and application can be divided into several groups. Instrumental methods including the X-ray diffraction, infrared testing and thermal analysis are ones of them. They give relatively the most complete picture of the phase composition. The choice of identification method is strictly dependent on the composition of the material, as it was shown on the example of cement-based adhesives used in thermal insulation systems.
Źródło:
Prace Instytutu Techniki Budowlanej; 2012, R. 41, nr 3, 3; 3-15
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The assessment of the ionizing radiation dose received by patients during some diagnostic X-ray examinations carried out on the basis of the working procedures in the health care entities
Autorzy:
Bekas, M.
Waniewska, E.
Wardzinski, A.
Wieprzowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/874288.pdf
Data publikacji:
2017
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
assessment
ionizing radiation
radiation dose
patient
diagnostic method
X-ray method
radiation exposure
working procedure
health care
human health
health risk
Opis:
Background. X-ray examination is a popular and universally used injury and disease diagnostic method. A distinctive X ray examination feature is that it can be done quickly which is extremely important in case of the need for rapid diagnosis of patients in life threatening condition. Another advantage of the X-ray examinations is also relatively low cost of carry. However, X-ray examination involve adverse health effects. During the examination the patient is subjected to ionizing radiation that might have impact on his health. Objective. The aim of this study has been to determine and assess the size of the entrance surface doses (ESD) received by patients during selected X-ray examinations performed on the basis of the medical working procedures available in healthcare entities in Masovian Voivodeship in Poland. Materials and Method. The examinations were conducted for 71 X-ray units located in the Masovian Voivodeship. Measurements of doses received by the patients were based on our own validated test methods. Results. It was found that the range applied to the high voltage in healthcare entities does not always coincide with the values specified in the standard procedures. It was found in the skull projection radiography AP and LAT that the recorded values were from range 60 to 82 kV (the average value of 74 kV) while in accordance with a standard procedure they should be in the range from 65 to 75 kV. Only in case of cervical spine radiography in the AP projection, the LAT exposure conditions were matching with the standard obligatory procedures in Poland. The consequence of selecting exposure conditions are significant differences in the size of the doses the patient receive during the same medical procedures. The greatest range of ESD doses was found during radiography of the thoracic spine in the projection AP and LAT. The projection LAT measured values were in the range of 523 to 10550 μGy (average value 2175 μGy). Conclusions. It is necessary to update immediately the standard procedures and to develop detailed guidelines for the preparation of working procedures in X-ray rooms.
Wprowadzenie. Badania rentgenowskie są powszechnie stosowaną metodą diagnozowania urazów i schorzeń występujących u pacjentów. Największą zaletą tych badań jest szybkość ich wykonania, co jest niezwykle istotne w przypadku konieczności postawienia szybkiej diagnozy medycznej u pacjentów w ciężkim stanie zagrażającym ich życiu. Badania rentgenowskie niosą jednakże ze sobą także negatywne skutki zdrowotne. W trakcie ich przeprowadzania pacjent poddany jest działaniu promieniowania jonizującego, które nie jest obojętne dla zdrowia. Cel. Celem badań było oszacowanie wielkości wejściowej dawki powierzchniowej (ESD) jaką otrzymują pacjenci podczas wybranych badań rentgenowskich przeprowadzonych w oparciu o procedury robocze obowiązujące w placówkach ochrony zdrowia na terenie województwa mazowieckiego. Materiał i metody. Zbadano 71 aparatów rentgenowskich wykorzystywanych w placówkach ochrony zdrowia na terenie województwa mazowieckiego. Pomiary dawek otrzymywanych przez pacjentów podczas badań rentgenowskich przeprowadzono własnymi zwalidowanymi metodami badawczymi. Wyniki. Stwierdzono, iż zakres wartości wysokiego napięcia dobieranego przez personel medyczny na aparatach rentgenowskich w placówkach ochrony zdrowia nie zawsze pokrywa się z wartościami określonymi w procedurach wzorcowych. Stwierdzono, iż w radiografii czaszki w projekcji AP i LAT wartość wysokiego napięcia była od 60 do 82 kV (wartość średnia 74 kV), zaś zgodnie z procedurą wzorcową powinny mieścić się w zakresie od 65 do 75 kV. Najlepszą zgodność pomiędzy wartościami wysokiego napięcia stosowanymi w pracowniach rtg a tymi określonymi w procedurach wzorcowych obowiązujących w Polsce stwierdzono w przypadku radiografii kręgosłupa szyjnego. Konsekwencją tak dobieranych warunków ekspozycji są znaczące różnice w wielkości dawek promieniowania otrzymywanych przez pacjentów dla tych samych procedur medycznych. Największą rozpiętość dawek ESD stwierdzono w trakcie radiografii kręgosłupa piersiowego w projekcji AP oraz LAT. W projekcji LAT zmierzone wartości były w przedziale od 523 do 10550 μGy (wartość średnia 2175 μGy). Wnioski. Niezbędne jest jak najszybsze uaktualnienie procedur wzorcowych oraz opracowanie szczegółowych wytycznych dotyczących przygotowywania procedur roboczych w pracowniach rentgenowskich.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2017, 68, 1
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of Size Distribution of Guinier-Preston Zones in Al-Ag Alloys by Small-Angle X-ray Scattering Method
Autorzy:
Bierska, B.
Pająk, L.
Powiązania:
https://bibliotekanauki.pl/articles/2035487.pdf
Data publikacji:
2002-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.10.Eq
81.40.Cd
64.75.+g
Opis:
Small-angle X-ray scattering method recognised to be very useful in the studies of structural problems of materials inhomogeneous in nanoscale. Studies by small-angle X-ray scattering on the Al-Ag alloys are presented. The size distributions of spherical Guinier-Preston zones were calculated using Vonk's and Glatter's methods. Small-angle X-ray scattering studies were performed on Al-5.0 at.%Ag alloy containing spherical Guinier-Preston zones in theη-state. For this alloy one can assume that scattering particles are of spherical shape, have uniform electron density and scatter independently. Moreover, the size distributions were calculated for Al-1.6 at.%Ag alloy containing Guinier-Preston zones in ε-state (scattering particles with not uniform electron density). Both, Vonk's and Glatter's, methods gave similar size distributions. Profiles of size distributions for Guinier-Preston zones inε-state are more complex in comparison to Guinier-Preston zones inη-state. It is connected with a complex structure of Guinier-Preston zones in ε-state. A modification of the structure model of Guinier-Preston zones inε-state is proposed.
Źródło:
Acta Physica Polonica A; 2002, 102, 2; 227-232
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new statistical reconstruction method for the computed tomography using an X-ray tube with flying focal spot
Autorzy:
Cierniak, Robert
Pluta, Piotr
Waligóra, Marek
Szymański, Zdzisław
Grzanek, Konrad
Pałka, Filip
Piuri, Vincenzo
Powiązania:
https://bibliotekanauki.pl/articles/2031110.pdf
Data publikacji:
2021
Wydawca:
Społeczna Akademia Nauk w Łodzi. Polskie Towarzystwo Sieci Neuronowych
Tematy:
computed tomography
iterative statistical reconstruction method
flying focal spot
Opis:
This paper presents a new image reconstruction method for spiral cone- beam tomography scanners in which an X-ray tube with a flying focal spot is used. The method is based on principles related to the statistical model-based iterative reconstruction (MBIR) methodology. The proposed approach is a continuous-to-continuous data model approach, and the forward model is formulated as a shift-invariant system. This allows for avoiding a nutating reconstruction-based approach, e.g. the advanced single slice rebinning methodology (ASSR) that is usually applied in computed tomography (CT) scanners with X-ray tubes with a flying focal spot. In turn, the proposed approach allows for significantly accelerating the reconstruction processing and, generally, for greatly simplifying the entire reconstruction procedure. Additionally, it improves the quality of the reconstructed images in comparison to the traditional algorithms, as confirmed by extensive simulations. It is worth noting that the main purpose of introducing statistical reconstruction methods to medical CT scanners is the reduction of the impact of measurement noise on the quality of tomography images and, consequently, the dose reduction of X-ray radiation absorbed by a patient. A series of computer simulations followed by doctor’s assessments have been performed, which indicate how great a reduction of the absorbed dose can be achieved using the reconstruction approach presented here.
Źródło:
Journal of Artificial Intelligence and Soft Computing Research; 2021, 11, 4; 271--286
2083-2567
2449-6499
Pojawia się w:
Journal of Artificial Intelligence and Soft Computing Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fabrication and Crystal Structure of Sol-Gel Deposited BST thin Films with Compositional Gradient
Autorzy:
Czekaj, D.
Lisińska-Czekaj, A.
Plewa, J.
Powiązania:
https://bibliotekanauki.pl/articles/356193.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ba1-xSrxTiO3 thin films
compositionally graded structure
sol-gel method
simultaneous thermal analysis
X-ray diffraction
Opis:
In the present research technology of compositionally graded barium strontium titanate Ba1-xSrxTiO3 thin films deposited on stainless steel substrates by sol-gel spin coating followed with thermal annealing at T = 650°C is reported. Results of thermal behavior of the sol-gel derived powders with compositions used for fabrication of graded structure (i.e. with Sr mole fraction x =0.5, 0.4 and 0.3) are described. X-ray diffraction studies of the phase composition and crystal structure of such complex thin film configuration are given. It was found that gel powders exhibited a large total weight loss of about Δm ≈ 44-47%. Three stages of weight loss took place at temperature ranges: below T ≈ 300°C, at ΔT ≈ 300-500°C and between T = 600°C and T = 800°C. Phase analysis has shown that the dominating phase is Ba0.67Sr0.33TiO3 compound while the second phase is Ba0.7Sr0.3TiO3 or Ba0.5Sr0.5TiO3 for “up-graded” and “down-graded” structure, respectively.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2A; 673-678
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Surfactant Addition on Bi2Te3 Nanostructures Synthesized by Hydrothermal Method
Autorzy:
Dharmaiah, P.
Lee, C. H.
Madavali, B.
Hong, S.-J.
Powiązania:
https://bibliotekanauki.pl/articles/351609.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bismuth telluride
hydrothermal synthesis
spark plasma sintering
thermoelectric materials
X-ray diffraction
Opis:
In the present work, we have prepared Bi2Te3 nanostructures with different morphologies such as nano-spherical, nanoplates and nanoflakes obtained using various surfactant additions (EG, PVP, and EDTA) by a hydrothermal method. The shape of the nanoparticles can be controlled by addition of surfactants. The samples were characterized by x-ray diffraction (XRD) and scanning electron microscopy (SEM). It is found that the minority BiOCl phase disappears after maintained pH at 10 with EG as surfactant. SEM bulk microstructure reveals that the sample consists of fine and coarse grains. Temperature dependence of thermoelectric properties of the nanostructured bulk sample was investigated in the range of 300-450K. The presence of nanograins in the bulk sample exhibits a reduction of thermal conductivity and less effect on electrical conductivity. As a result, a figure of merit of the sintered bulk sample reached 0.2 at 400 K. A maximum micro Vickers hardness of 102 Hv was obtained for the nanostructured sample, which was higher than the other reported results.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2B; 1005-1010
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method for Filling and Sharpening False Colour Layers of Dual Energy X-ray Images
Autorzy:
Dmitruk, K.
Mazur, M.
Denkowski, M.
Mikołajczak, P.
Powiązania:
https://bibliotekanauki.pl/articles/227318.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
X-ray imaging
image processing
false colour
object detection
Opis:
An X-ray scanning and image processing have a vast range of applications in the security. An image of a content of some package being passed for example to an airplane or to the court house may help to figure out if there are any dangerous objects inside that package and to avoid possible threatening situation. As the raw X-ray images are not always easy to analyze and interpret, some image processing methods like an object detection, a frequency resolution increase or a pseudocolouring are being used. In this paper, we propose a pseudocoloring improvement over material based approach. By addition of the edge detection methods we fill and sharpen colour layers over the image, making it easier to interpret. We demonstrate the effectiveness of the methods using real data, acquired from a professional dual energy X-ray scanner.
Źródło:
International Journal of Electronics and Telecommunications; 2016, 62, 1; 49-54
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of the tension and compression behavior of sintered 316L using micro computed tomography
Autorzy:
Doroszko, M.
Seweryn, A.
Powiązania:
https://bibliotekanauki.pl/articles/387023.pdf
Data publikacji:
2015
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
finite element method
X-ray microtomography
porous materials
mechanical properties
plasticity
metoda elementów skończonych (MES)
mikrotomografia rentgenowska
materiały porowate
plastyczność
właściwości mechaniczne
Opis:
This paper describes the method of numerical modeling of the tension and compression behavior of sintered 316L. In order to take into account the shape of the mesostructures of materials in the numerical modeling, X-ray microtomography was used. Based on the micro-CT images, three-dimensional geometrical models mapped shapes of the porosity were generated. To the numerical calculations was used finite element method. Based on the received stress and strain fields was described the mechanism of deformation of the materials until fracture. The influence of material discontinuities at the mesoscopic scale on macromechanical properties of the porous materials was investigated.
Źródło:
Acta Mechanica et Automatica; 2015, 9, 2; 70-74
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-Ray Diffraction Measurements for Riveted Joints. The Application of a Novel Methodology
Autorzy:
Gadalińska, E.
Kaniowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/97767.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
X-ray diffraction method
stress measurements
riveted joints
Opis:
The X-ray diffraction method is the best, widely available, non-destructive measurement method used to determine the residual and load stresses in crystalline materials. This method can be applied without any limitations to flat specimens. Depending on the equipment geometry, the type of material and geometry of the specimen, there are many limitations, restrictions and recommendations which have to be fulfilled to obtain reliable results. This was the reason for working out a methodology for X-ray diffraction stress measurements for riveted specimens.The first case to analyze is the necessity of choosing an X-ray tube suitable for the specimen material which will give the diffraction peaks in the range of 2Θ angles between 120° and 180°. Afterwards it is crucial to make the best selection of Bragg's angle 2Θ. In the vast majority of cases the best selection is the possibly biggest 2Θ angle because of the best accuracy of the measurement. However, for example for aluminum alloys (for CrKα radiation), this choice is not so obvious. It is much more convenient to perform measurements not for the highest diffraction angle. The best selection in this case is 2Θ=139,3°, and not 156,7°. Other selections which are necessary to be made before measurements are the collimator diameter, time of exposure, ψ tilts and φ oscillations. The proper selection of these parameters is crucial for the fast and efficient performing of measurements and for obtaining reliable results. Before performing the measurement, especially in the case of the specimen with complicated geometry (for example in the case of riveted specimens made of aluminum alloys), it is necessary to analyze the results obtained paying special attention to the possibility of the appearing of the rivet head/driven rivet head shadow during the measurement. The work describes differences between the X-ray stress measurement results obtained without any interference and the results received after eliminating the selected diffraction peaks for which the shadow of rivet head/driven rivet head has appeared.
Źródło:
Fatigue of Aircraft Structures; 2012, 4; 17-28
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda spektrometrii fluorescencji rentgenowskiej alternatywą dla badań niszczących przy podejmowaniu decyzji o próbie wyrobów ze stopów metali szlachetnych
The method of X-ray fluorescence spectrometry as an alternative to destructive testing when making a decision on the standards of articles of precious metal alloys
Autorzy:
Górkiewicz-Malina, Aleksandra
Kowalówka, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/1819338.pdf
Data publikacji:
2021
Wydawca:
Główny Urząd Miar
Tematy:
metale szlachetne
wyroby ze złota
probiernictwo
metoda fluorescencji rentgenowskiej
precious metals
gold articles
hallmarking
method of X-ray fluorescence spectrometry
Opis:
W artykule rozważano przypadki możliwości podejmowania decyzji o próbie stopów, z których wykonane są wyroby jubilerskie, z pominięciem analitycznych metod niszczących, na podstawie badań metodą spektrometrii fluorescencji rentgenowskiej oraz powszechnie stosowanej metody przybliżonej, na kamieniu probierczym.
The article considers cases of the possibility of making a decision on the testing of alloys from which jewellery is made, by passing the destructive analytical methods and on the basis of X-ray fluorescence spectrometry and commonly used touchstone method.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2021, 1 (26); 37--46
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TiO2 thin films grown on SiO2–Si(111) by the reactive evaporation method
Autorzy:
Grodzicki, M
Wasielewski, R
Mazur, P
Zuber, S
Ciszewski, A
Powiązania:
https://bibliotekanauki.pl/articles/173459.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
titanium oxide
wettability
X-ray photoelectron spectroscopy
UV radiation
Opis:
TiO2 thin films were grown on silicon substrates using an electron-beam evaporator. Grainy TiO was used as the evaporation material. Temperature substrate during TiO2 growth was relatively low (about 150 °C), what is important for many optoelectronic devices and multilayers mirrors. High vacuum condition allows to maintain clean surfaces substrates before and during oxide growth. The morphology of titanium oxide thin films was ex situ investigated using atomic force microscopy operating in contact mode, X-ray photoelectron spectroscopy, X-ray powder diffractometry, and by means of a contact angle analyzer. The influence of annealing treatment and exposure to UV–VIS radiation on the morphology has been also discussed.
Źródło:
Optica Applicata; 2013, 43, 1; 99-107
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Importance of wheat grain orientation for the detection of internal mechanical damage by the X-ray method
Autorzy:
Grundas, S.
Velikanov, L.
Archipov, M.
Powiązania:
https://bibliotekanauki.pl/articles/25784.pdf
Data publikacji:
1999
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
grain hardness
internal damage
X-ray method
mechanical damage
wheat grain
Źródło:
International Agrophysics; 1999, 13, 3
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podatność ziarna pszenicy i pszenżyta na uszkodzenia bielma oznaczana metodą rentgenograficzną
Susceptibility of wheat and triticale grain to inner mechanical damage by using the X-ray method
Autorzy:
Grundas, S.
Gruszecka, D.
Kowalczyk, K.
Niewiadomski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/35564.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
pszenica
pszenzyto
ziarno
uszkodzenia ziarna
bielmo
podatnosc na uszkodzenia
metody rentgenograficzne
wheat
triticale
grain
grain damage
endosperm
damage susceptibility
X-ray method
Opis:
Artykuł zawiera wyniki rentgenograficznych badań podatności ziarna pszenicy i pszenżyta na powstawanie uszkodzeń bielma. Materiał pochodził z doświadczeń polowych (eksperyment 1) przeprowadzonych w Stacji Hodowli Roślin w Laskach, w latach 2005-2007 oraz z doświadczeń prowadzonych na mieszańcach pszenżyta przez Instytut Genetyki, Hodowli i Biotechnologii Roślin UP w Lublinie w roku 2009 (eksperyment 2). Zarejestrowany metodą rentgenowską udział ziarniaków z pęknięciami poprzecznymi bielma wskazuje na genetyczne uwarunkowanie tego typu uszkodzeń.
The paper presents the results of X-ray investigations of wheat and triticale grain susceptibility to endosperm damage. The experimental material originated from field experiments carried out at the Plant Breeding Station in Laski in 2005-2007 (experiment 1), and from experiments carried out on grain hybrids of Triticale at the Institute of Genetics, Breeding and Plants Biotechnology at the University of Life Sciences in Lublin, in 2009 (experiment 2). The share of kernels with inner cracks, registered with the X-ray method, indicates an influence of genetic factors on the occurrence of this kind of damage.
Źródło:
Acta Agrophysica; 2011, 18, 2[193]
1234-4125
Pojawia się w:
Acta Agrophysica
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies