Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wrzesień, Małgorzata" wg kryterium: Wszystkie pola


Tytuł:
Exposure to ionizing radiation by service personnel working with cyclotrons used to produce radiopharmaceuticals in PET diagnostics
Autorzy:
Biegała, Michał
Jakubowska, Teresa
Wrzesień, Małgorzata
Albiniak, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2152980.pdf
Data publikacji:
2022
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
nuclear medicine
PET
equivalent dose
service
radiological protection
cyclotron
Opis:
Objectives While working with cyclotrons used for the production of radiopharmaceuticals, workers can experience significant exposure to the adverse effects of ionizing radiation. The aim of this paper was to determine the typical level of such exposure received by such personnel while servicing cyclotrons. Material and Methods Exposure was assessed using TLD detectors placed in an anthropomorphic phantom, as well as dose meter to determine whole body and eye lens exposure. The phantom was placed in locations receiving the greatest exposure to ionizing radiation during service activities. The time spent by employees during servicing was assessed based on routine visits by service technicians. The obtained results were compared with readings of detectors worn by employees during service activities. Results The highest equivalent doses in the thoracic area were found to be received by the lungs (211.16 μSv/year). In the head and neck area, the highest dose was measured in the eye lens (3410 μSv/year). The effective dose for the whole body was found to be 1154.4 μSv/year, based on the phantom, and 149 μSv per service visit (1192 μSv/year), based on the dose meters carried by the workers. Conclusions Service workers are exposed to significant doses of ionizing radiation, representing a clear radiological protection issue. To reduce exposure to eye lenses, it is recommended to use protective goggles when working with highly-radioactive elements.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2022, 35, 6; 753-760
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obiad literacki
Autorzy:
Boy-Żeleński, Tadeusz
Współwytwórcy:
Kozioł, Paweł
Choromańska, Paulina
Wrzesień, Małgorzata
Data publikacji:
2013-02-05
Wydawca:
Fundacja Nowoczesna Polska
Tematy:
Dwudziestolecie międzywojenne
Epika
Felieton
Opis:
Publikacja zrealizowana w ramach projektu Wolne Lektury (http://wolnelektury.pl). Reprodukcja cyfrowa wykonana przez fundację Nowoczesna Polska z książki udostępnionej przez Łukasza Jachowicza.
Źródło:
Tadeusz Boy-Żeleński, Obiad literacki, Bibljoteka Boya, Drukarnia Zakładów Wydawniczych M. Arct, s.a., Warszawa [1934]
Dostawca treści:
Wolne Lektury
Książka
Tytuł:
Zmysły... zmysły...
Autorzy:
Boy-Żeleński, Tadeusz
Współwytwórcy:
Niedziałkowska, Marta
Kozioł, Paweł
Choromańska, Paulina
Wrzesień, Małgorzata
Data publikacji:
2012-10-15
Wydawca:
Fundacja Nowoczesna Polska
Tematy:
Dwudziestolecie międzywojenne
Epika
Felieton
Opis:
Publikacja zrealizowana w ramach projektu Wolne Lektury (http://wolnelektury.pl). Reprodukcja cyfrowa wykonana przez Fundację Nowoczesna Polska z egzemplarza pochodzącego ze zbiorów Łukasza Jachowicza.
Źródło:
Tadeusz Boy-Żeleński, Zmysły... zmysły, Bibljoteka Boya, Warszawa 1932
Dostawca treści:
Wolne Lektury
Książka
Tytuł:
Invasive flora within urban railway areas: a case study from Lublin (Poland) and Lviv (Ukraine)
Flora inwazyjna terenów kolejowych w obrębie miast – Lublina (Polska) i Lwowa (Ukraina)
Autorzy:
Denisow, Bożena
Wrzesień, Małgorzata
Mamchur, Zvenyslava
Chuba, Maria
Powiązania:
https://bibliotekanauki.pl/articles/1628057.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Botaniczne
Tematy:
vascular flora
native species
neophytes
invasive species
biological traits
Opis:
Heterogeneous and disturbed habitats within railway areas create an ideal environment for establishment of invasive plant species. In this study, we compared the invasive species composition and abundance within railway areas of two cities, Lublin, SE Poland and Lviv, W Ukraine. In total, 70 invasive species were recorded. The invasive species list was similar for the two cities, with the most invasive species occurring at both (81.4%), 8.5% occurring only in Lublin and 10% only in Lviv. The proportion of invasive species in the total flora was almost 1.5-fold higher at Lviv compared to Lublin. Invasive species have originated mainly from continental America (45.7%), followed by Asia and Eurasia. The participation of invasive plants derived from Asia and Eurasia at Lviv is higher than at Lublin. The invasive flora includes a wide range of taxonomic groups, with a predominance of Asteraceae and Poaceae. The ecological attributes of invasive species on railway areas are: mainly annual therophytes, mostly wind- and insect pollination modes, a predominance of generative reproduction, anthropochorous and anemochorous dispersal and short-term persistent, long-term persistent or transient seed banks.
Zróżnicowane i zaburzone siedliska w obrębie terenów kolejowych tworzą środowisko do zadomowienia obcych gatunków roślin. W pracy porównano skład oraz bogactwo gatunkowe gatunków inwazyjnych notowanych w obrębie terenów kolejowych Lublina (południowo-wschodnia Polska) oraz Lwowa (zachodnia Ukraina). Zanotowano 70 gatunków inwazyjnych. Skład gatunkowy flory inwazyjnej był w obu miastach podobny; 81.4% gatunków inwazyjnych notowano w obu miastach, 8.5% tylko w Lublinie, a 10% tylko we Lwowie. Udział gatunków inwazyjnych we florze Lwowa był wyższy w porównaniu z florą Lublina. Gatunki inwazyjne pochodziły głównie z Ameryki (45.7% gatunków), Azji i Eurazji. Udział gatunków inwazyjnych przybyłych z Azji i Eurazji był wyższy we Lwowie niż w Lublinie. Gatunki należące do rodziny Asteraceae i Poaceae dominowały wśród gatunków inwazyjnych. Analiza cech ekologicznych gatunków inwazyjnych zasiedlających tereny kolejowe wykazała, że są to głównie rośliny jednoroczne, wiatro- lub owadopylne, rozmnażające się generatywnie, o nasionach rozsiewających się antropochorycznie lub anemochorycznie, tworzące krótkotrwały lub długotrwały bank nasion.
Źródło:
Acta Agrobotanica; 2017, 70, 4
0065-0951
2300-357X
Pojawia się w:
Acta Agrobotanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stosunek władz i społeczeństwa Litwy do Polaków na Wileńszczyźnie wrzesień 1939 --- czerwiec 1940 : (na podstawie prasy litewskiej)
Autorzy:
Kasperavičius, Algis.
Powiązania:
Społeczeństwo białoruskie, litewskie i polskie na ziemiach północno-wschodnich II Rzeczypospolitej (Białoruś Zachodnia i Litwa Wschodnia) w latach 1939-1941: [materiały z konferencji naukowej, Warszawa 24-26 listopad 1993 r.] / pod red. Małgorzaty Giżejewskiej i Tomasza Strzembosza Warszawa, 1995 S. 307-315
Współwytwórcy:
Giżejewska, Małgorzata. Redakcja
Strzembosz, Tomasz. Redakcja
Opis:
Bibliogr. --- Rez., Sum.
Dostawca treści:
Bibliografia CBW
Artykuł
Tytuł:
Sprawozdanie z prac sondażowo-topograficznych w Miednoje -- wrzesień 1994
Autorzy:
Młodziejowski, Bronisław.
Powiązania:
Zbrodnia katyńska : historia -- rzeczywistość -- prawda : materiały Ogólnopolskiej Sesji Naukowej w 55 rocznicę zbrodni katyńskiej, [28-29 kwietnia 1995]. [Cz. 1] Gdańsk-Gdynia, 1995 S. 9-16
Współwytwórcy:
Książek-Czermińska, Małgorzata. Redakcja
Wejsflog-Rodziewicz, Ewa. Redakcja
Ząbczyk-Chmielewska, Barbara. Redakcja
Data publikacji:
1995
Tematy:
Ogólnopolska Sesja Naukowa nt.: Zbrodnia Katyńska. Historia -- Rzeczywistość -- Prawda (28-29.04.1995; Gdańsk-Gdynia)
Groby żołnierskie polskie badania Miednoje 1994 r. materiały konferencyjne
Dostawca treści:
Bibliografia CBW
Artykuł
Tytuł:
Ocena rentgenowskich aparatów stomatologicznych pod kątem narażenia pacjentów na promieniowanie jonizujące
Evaluation of dental X-ray apparatus in terms of patient exposure to ionizing radiation
Autorzy:
Olszewski, Jerzy
Wrzesień, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2164069.pdf
Data publikacji:
2017-06-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
pacjent
promieniowanie rentgenowskie
radiologia stomatologiczna
wejściowa dawka powierzchniowa (ESD)
ankieta
detektory termoluminescencyjne
patient
X-ray
dental radiology
entrance surface dose (ESD)
questionnaire
thermoluminescent dosimeter
Opis:
Wstęp Stosowanie w procedurach stomatologicznych promieniowania rentgenowskiego (rtg.) powoduje narażenie pacjenta na promieniowanie jonizujące. Wielkość tego narażenia zależy przede wszystkim od parametrów stosowanych przy prześwietleniu zęba. Celem badań było określenie wielkości dawek, na jakie narażeni są pacjenci, oraz ocena stanu technicznego aparatów rtg. Materiał i metody Badaniami ankietowymi objęto 1700 gabinetów stomatologicznych. Ankiety odesłało 740 jednostek. Pomiary bezpośrednie wykonano w 100 gabinetach. Pomiary wykonano za pomocą detektorów termoluminescencyjnych i klisz rtg. Wyniki W przeprowadzonych badaniach stwierdzono, że najczęściej stosowany czas ekspozycji wynosi 0,22±0,16 s. Średnia dawka wejściowa dla parametrów najczęściej stosowanych przez stomatologów to 1,7±1,4 mGy. Średnia wydajność lampy rtg. oszacowana na podstawie wykonanych ekspozycji wynosi 46,5±23,7 μGy/mAs. Wnioski Jak wynika z przeprowadzonych badań, znakomita większość aparatów rtg. punktowych spełnia wymagania określone w przepisach. Med. Pr. 2017;68(4):491–496
Background The use of X-ray in dental procedures causes exposure of the patient to ionizing radiation. This exposure depends primarily on the parameters used in tooth examination. The aim of the study was to determine the patients exposure and to assess the technical condition of X-ray tubes. Material and Methods Seventeen hundred dental offices were covered by the questionnaire survey and 740 questionnaires were sent back. Direct measurements were performed in 100 units by using the thermoluminescent detectors and X-ray films. Results The results showed that the most commonly used exposure time is 0.22±0.16 s. The average entrance dose for the parameters used most commonly by dentists is 1.7±1.4 mGy. The average efficiency of X-ray tube estimated on the basis of exposures is 46.5±23.7 μGy/mAs. Conclusions The study results indicate that the vast majority of X-ray tubes meet the requirements specified in the binding regulations. Med Pr 2017;67(4):491–496
Źródło:
Medycyna Pracy; 2017, 68, 4; 491-496
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Występowanie radonu w polskich podziemnych trasach turystycznych
Occurrence of radon in the Polish underground tourist routes
Autorzy:
Olszewski, Jerzy
Zmyślony, Marek
Wrzesień, Małgorzata
Walczak, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/2164496.pdf
Data publikacji:
2015-10-08
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
Polska
radon
podziemne trasy turystyczne
stężenie radonu
promieniotwórczość naturalna
środowisko
Polska
underground tourists rout
radon concentration
natural radioactivity
environment
Opis:
Wstęp W Polsce funkcjonuje około 200 podziemnych tras turystycznych. Są to jaskinie, kopalnie oraz podziemne budowle. W niniejszej pracy przedstawiono wyniki badań mających na celu rozpoznanie zakresu występowania stężeń radonu we wnętrzach podziemnych tras turystycznych. Materiał i metody W celu oszacowania stopnia zagrożenia przeprowadzono okresowe (1–2-miesięczne) pomiary stężeń radonu. Wykonano je w okresie letnim za pomocą detektorów śladowych typu Tastrak. Określono średnie stężenie radonu w powietrzu w 66 podziemnych trasach turystycznych w Polsce. Wyniki W wyniku przeprowadzonych badań uzyskano 259 pomiarów średnich stężeń radonu. Średnia arytmetyczna wyników wyniosła 1610 Bqm⁻³, maksymalne zmierzone stężenie – ponad 20 tys. Bqm⁻³, a stężenie minimalne – 100 Bqm⁻³ (próg czułości metody). Stwierdzono, że w 67% tras średnie stężenie radonu przekroczyło wartość 300 Bqm⁻³, natomiast w 22 podziemnych trasach przekroczyło 1000 Bqm⁻³. Wnioski Występujący w podziemnych trasach turystycznych radon w wielu przypadkach może stanowić problem organizacyjno-prawny i zdrowotny. Należy opracować program działań, których celem będzie obniżenie stężeń radonu w podziemnych trasach, szczególnie zlokalizowanych w zamkniętych kopalniach. Med. Pr. 2015;66(4):557–563
Background There are about 200 underground tourist routes in Poland. There are caves, mines or underground structures. This paper presents the results of the research intended to identify the extent of the occurrence of radon concentrations in underground areas of tourist routes. Material and Methods We conducted the measurement of periodic concentrations of radon (1–2 months) in the summer using type Tastrak trace detectors. We determined the average concentrations of radon in air in 66 underground tourist routes in Poland. Results The research results comprise 259 determinations of average radon concentrations in 66 routes. The arithmetic average of the results was 1610 Bqm⁻³, and the maximum measured concentration was over 20 000 Bqm⁻³. The minimum concentration was 100 Bqm⁻³ (threshold method) considering the arithmetic average of the measurements. It was found that in 67% of the routes, the average concentration of radon has exceeded 300 Bqm⁻³ and in 22 underground routes it exceeded 1000 Bqm⁻³. Conclusions Radon which occurs in many Polish underground tourist routes may be an organizational, legal and health problem. It is necessary to develop a program of measures to reduce radon concentrations in underground routes, especially routes located in the former mines. Med Pr 2015;66(4):557–563
Źródło:
Medycyna Pracy; 2015, 66, 4; 557-563
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pochwała dawnej dzielności greckiej
Autorzy:
Przerwa-Tetmajer, Kazimierz
Współwytwórcy:
Niedziałkowska, Marta
Kozioł, Paweł
Wrzesień, Małgorzata
Data publikacji:
2012-10-11
Wydawca:
Fundacja Nowoczesna Polska
Tematy:
Modernizm
Wiersz
Liryka
Opis:
Publikacja zrealizowana w ramach projektu Wolne Lektury (http://wolnelektury.pl). Reprodukcja cyfrowa wykonana przez Bibliotekę Narodową z egzemplarza pochodzącego ze zbiorów BN.
Źródło:
Kazimierz Przerwa-Tetmajer, Wybór poezji, nakł. Gebethnera i Wolffa, Warszawa-Kraków 1897
Dostawca treści:
Wolne Lektury
Książka
Tytuł:
Społeczeństwo Wileńszczyzny wobec władzy litewskiej i sowieckiej : (wrzesień 1939 --- czerwiec 1941)
Autorzy:
Tomaszewski, Longin.
Powiązania:
Społeczeństwo białoruskie, litewskie i polskie na ziemiach północno-wschodnich II Rzeczypospolitej (Białoruś Zachodnia i Litwa Wschodnia) w latach 1939-1941: [materiały z konferencji naukowej, Warszawa 24-26 listopad 1993 r.] / pod red. Małgorzaty Giżejewskiej i Tomasza Strzembosza Warszawa, 1995 S. 326-333
Współwytwórcy:
Giżejewska, Małgorzata. Redakcja
Strzembosz, Tomasz. Redakcja
Opis:
Bibliogr. --- Rez., Sum.
Dostawca treści:
Bibliografia CBW
Artykuł
Tytuł:
Absorbed doses for patients undergoing panoramic radiography, cephalometric radiography and CBCT
Autorzy:
Wrzesień, Małgorzata
Olszewski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/2161887.pdf
Data publikacji:
2017-07-17
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
thermoluminescence
panoramic radiography
absorbed dose
CBCT
cephalometric radiography
thermoluminescent detectors
Opis:
Objectives Contemporary dental radiology offers a wide spectrum of imaging methods but it also contributes to an increase in the participation of dental radiological diagnosis in the patient’s exposure to ionizing radiation. The aim of this study is to determine the absorbed doses of the brain, spinal column, thyroid and eye lens for patients during panoramic radiography, cephalometric radiography and cone beam computed tomography (CBCT). Material and Methods The thermoluminescent dosimetry and anthropomorphic phantom was used for measuring the doses. The 15 panoramic, 4 cephalometric and 4 CBCT exposures were performed by placing high-sensitivity thermoluminescent detectors (TLD) in 18 anatomical points of the phantom. Results The maximum absorbed dose recorded during performed measurements corresponds to the point representing the brainstem and it is 10 mGy. The dose value recorded by the TLD placed in the thyroid during CBCT imaging in relation to the panoramic radiography differs by a factor of 13.5. Conclusions Cone beam computed tomography, in comparison with panoramic or cephalometric imaging technique, provides higher radiation doses to the patients. Int J Occup Med Environ Health 2017;30(5):705–713
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 5; 705-713
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calibration of thermoluminescent detectors in Hp(0.07) units by using an X-ray tube and a ¹³⁷Cs source
Autorzy:
Wrzesień, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2164013.pdf
Data publikacji:
2019-12-03
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
thermoluminescence
Hp(0.07)
calibration
X-ray
Dosimetry
nuclear medicine
Opis:
Background The method of measuring doses based on the thermoluminescence phenomenon is not an absolute method. For this reason, to obtain correct results, it is necessary to calibrate detectors in the known radiation field. This paper presents a method for calibrating thermoluminescent detectors used in the measurement of personal dose equivalents (Hp(0.07)) obtained by nuclear medicine facility personnel when handling the $\text{}^{99m} \text{Tc}$ radionuclide. Material and Methods The authors used self-developed high-sensitivity thermoluminescent detectors and a HF320C X-ray unit, as well as a rod phantom. Dosimeters were calibrated in accordance with the ISO 4037-3 standard. During the measurements a vial containing a $\text{}^{99m} \text{Tc}$ radionuclide with well-known activity was also used. The energy characteristics were supplemented by using a ¹³⁷Cs source (irradiator ⁶⁰Co/¹³⁷Cs). Results The value of the calibration coefficient for 118 keV energy energy was (1.90±0.02)×10⁻⁵ mSv/imp. Taking into account the correction factor specified for of 140 keV energy at 0.962, the value of the calibration coefficient for 140 keV energy was determined as (1.83±0.02)×10⁻⁵ mSv/imp. Conclusions Verification of the calibration coefficient determined for 140 keV energy carried out with a vial containing a $\text{}^{99m} \text{Tc}$ radionuclide confirmed the correctness of the procedure. Med Pr. 2019;70(6):669–73
Źródło:
Medycyna Pracy; 2019, 70, 6; 669-673
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies