Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Szetela, R." wg kryterium: Wszystkie pola


Wyświetlanie 1-7 z 7
Tytuł:
Modyfikacja obecnej postaci modelu osadu czynnego ASM 2d
Modification of the present form of the ASM 2d acivated sludge model
Autorzy:
Szetela, R.
Dymaczewski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/237564.pdf
Data publikacji:
2002
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie ścieków
oczyszczanie biologiczne
osad czynny
usuwanie fosforu
usuwanie substancji organicznych
usuwanie związków azotu
modelowanie matematyczne
Opis:
Pilot-scale investigations into nitrogen and phosphorus removal by the activated sludge process were carried out in the wastewater plant of Poznań. Under laboratory conditions, the following parameters were examined: Ammonia Utilization Rate (AUR), Nitrate Utilization Rate (NUR), Phosphorus Release Rate (PRR) and Phosphorus Uptake Rate (PUR) for the activated sludge coming from a pilot plant. With the results obtained it was possible to calibrate and verify the mathematical model describing the ASM 2d activated sludge for the pilot plant of interest. It was found that the predictions of phosphorus variations established in terms of the original ASM 2d model were inadequate when the untreated wastewater contained very high amounts of Volatile Fathy Acids (VFA). Despite the presence of VFA in the anoxic or oxic phase, phosphorus release terminated, followed by the initiation of phosphorus uptake, thus resulting in a rapid decrease of phosphates concentration in the solution. Under such conditions the ASM 2d model predicts further release of phosphates up to a complete VFA exhaustion. The proposed modification of the model includes the incorporation of two terms, Ko/(Ko+So) and Kno/(Kno+Sno), into the equation for the PHA storage rate, which results in the blocking of the process under oxic and anoxic conditions, respectively. With such modification it is possible to make the predictions of the model far more adequate to reality. In the study, consideration was also given to the problem of model calibration with respect to the denitrification effect.
Źródło:
Ochrona Środowiska; 2002, 1; 3-8
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jednowymiarowe modele natężenia i jakości ścieków dopływających do oczyszczalni komunalnych
One-dimensional models describing the parameters of the influent to the municipal wastewater treatment plant
Autorzy:
Sobota, J.
Szetela, R.
Powiązania:
https://bibliotekanauki.pl/articles/236798.pdf
Data publikacji:
2005
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
ścieki miejskie
natężenie dopływu
wskaźniki jakości
model autoregresji sezonowy
prognozowanie
municipal wastewater
influent flow ratio
organic constituents
seasonal autoregressive model
forecast
Opis:
Zarówno natężenie przepływu, jak i główne wskaźniki jakości ścieków dopływających do oczyszczalni, wykazują dobową powtarzalność. Zjawisko to, nazywane sezonowością, powinno być uwzględniane podczas budowania modeli prognostycznych i symulacyjnych. W pracy przedstawiono wyniki badań nad wyborem najlepszego modelu, opisującego wskaźniki ścieków dopływających do oczyszczalni komunalnych. Na podstawie przeprowadzonych analiz oraz wyników wcześniejszych prac stwierdzono, że klasyczny sezonowy model autoregresji postaci (delta)24Zt=(fi)1(delta)24Zt-1+at opisuje zmienność zarówno natężenia dopływu ścieków jak i wartości wskaźników tlenowych (BZT5, ChZT) lepiej niż niesezonowe modele autoregresji. Wykazano, że modele nie zawierające parametru sezonowości były nieadekwatne. Przy praktycznym zastosowaniu tego modelu okazało się jednak, że nie daje on zadowalających prognoz dla wskaźników nie mających dokładnej dobowej powtarzalności. W wypadku występowania silnych zakłóceń (np. w wyniku intensywnych opadów deszczu następowało zawyżanie prognozowanych wartości w następnej dobie. W pracy zaproponowano zmodyfikowany model w postaci Zt=(fi)1Zt-1+(fi)2Zt-24+(fi)3Zt-25+at inaczej uwzględniający dobową sezonowość. Dzięki temu jakość prognoz uległa znacznej poprawie, nawet w wypadku doby o nietypowej charakterystyce. Ze względu na małe wartości współczynnika (fi)3 oraz stosunkowo duże błędy tego estymatora, w niektórych przypadkach model upraszcza się do postaci Zt=(fi)1Zt-1+(fi)2Zt-24+bo+at. Stwierdzono, że szeregi czasowe niektórych wskaźników jakości nie wykazywały wyraźnego charakteru okresowego. W tym kontekście wprowadzono kryterium operujące pojęciem "pamięci procesu", pozwalające na wstępną ocenę trafności wyboru modelu sezonowego. Wskazano na pewną graniczną wartość "pamięci procesu", poniżej której szeregu czasowego nie daje się adekwatnie opisać modelem sezonowym.
Both the flow rate and the composition of the wastewater stream entering the plant follow a 24-hour diurnal pattern. This phenomenon (also refered to as seasonality) should be taken into account when constructing models for the needs of forecasting or simulation. Our investigations reported on in this paper concentrated on the choice of such a model that would best describe the influents to municipal wastewater treatment plants. Our analyses, as well as the results of our previous studies, have revealed that the classical seasonal autoregressive model (delta)24Zt=(fi)1(delta)24Zt-1+at describes the variability not only of the flow rate but also of the organic constituents (BOD5, COD) better than the nonseasonal autoregressive models. Models that did not include the seasonality parameter were found to be inadequate. It has been shown, however, that the classical seasonal model fails to yield reliable forecast, when applied to time series deviating from exact 24-hour repeatability. Whenever there were episodes of strong disturbance (e.g. due to heavy rainfall), they always produced overrated forecast values for the subsequent 24-hours. In our present paper, the classical model was modified to the form of Zt=(fi)1Zt-1+(fi)2Zt-24+(fi)3Zt-25+at. In this way it was possible to upgrade noticeably the quality of the forecasts, even if a 24-hour period displayed an atypical characteristic. In some cases, when the (fi)3 coefficient took low values, and its estimator error was big, the model was simplified to the form of Zt=(fi)1Zt-1+(fi)2Zt-24+bo+at. It was found that the time series for some wastewater constituents did not show a distinct seasonality. In this context, a criterion was introduced, which involved the notion "process memory", thus enabling the adequacy of the choice of the seasonal model to be preliminarily assessed. It was shown that there is a certain limit value of the "process memory" below which the time series can not be adequately described by the seasonal model.
Źródło:
Ochrona Środowiska; 2005, R. 27, nr 1, 1; 15-22
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tworzenie szeregów czasowych natężenia dopływu i parametrów jakości ścieków na potrzeby symulacji pracy oczyszczalni komunalnych
Simulating the performance of municipal wastewater treatment plants: Generation of the time series of inflow rate and quality parameters of the wastewater
Autorzy:
Sobota, J.
Szetela, R.
Powiązania:
https://bibliotekanauki.pl/articles/236468.pdf
Data publikacji:
2006
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczalnia ścieków
natężenie dopływu
jakość ścieków
szereg czasowy
zmienność sezonowa
symulacja
water treatment plant
flow rate
wastewater characteristics
time series
diurnal variations
daily variations
seasonal variations
simulation
Opis:
Możliwość tworzenia szeregów czasowych wejść oczyszczalni komunalnych, opisujących z godzinowym krokiem wartości natężenia przepływu i stężeń zanieczyszczeń dopływających ścieków, jest istotna w zagadnieniach projektowania i eksploatacji procesów oczyszczania ścieków. W pracy przedstawiono propozycje metody tworzenia takich wejść. Jej istotą jest wyodrębnienie z surowych przebiegów czasowych odpowiednich składowych deterministycznych (uśrednionych dobowych i rocznych "szkieletów" natężenia dopływu i stężenia zanieczyszczeń) i losowych, których modele są budowane osobno, a ich połączenie daje model generatora wejść. Wykazano, że generator dobrze naśladuje charakterystyczną zmienność sezonową, dobową i godzinową wejść oczyszczalni. Pozwala to na jego zastosowanie w analizach symulacyjnych, służących optymalizacji procesów technologicznych i strategii ich sterowania. Obecnie w większości oczyszczalni brak jest odpowiednio bogatych, kilkuletnich zbiorów danych źródłowych, obejmujących charakterystykę jakości ścieków surowych, niezbędnych do opracowania odpowiedniego generatora wejść. Na potrzeby takich przypadków zaproponowano metodologię alternatywną, wykorzystującą stwierdzone zależności korelacyjne pomiędzy średnim dobowym natężeniem dopływu ścieków i średnimi dobowymi wartościami wskaźników zanieczyszczeń ścieków surowych.
The potentiality for generating the time series of the inputs for municipal wastewater treatment plants such that describe, in hourly steps, the flow rates and concentrations of pollutants in the influent wastewater stream is of importance to the design and control of wastewater treatment processes. In this paper, a method is proposed for the generation of such inputs. The method consists in separating from the raw time series appropriate deterministic (averaged daily and annual 'skeletons' of inflow rate and pollutant concentrations) and stochastic components; their models are constructed separately, and the combination of those models produces the model of the input generator. The generator well imitates the characteristic seasonal, daily and hourly variability of the inputs for the wastewater treatment plant and can therefore be applied to simulation analyses aimed at optimizing technological processes and relevant control strategies. Presently, only few wastewater treatment plants in Poland are in possession of comprehensive data sets including the characteristic of raw wastewater quality recorded for several years, which are needed when designing an input generator. With these thoughts in mind, an alternative methodology is proposed, where use is made of the correlations between the average daily rate of wastewater inflow and the average daily concentrations of the pollutants in raw wastewater.
Źródło:
Ochrona Środowiska; 2006, R. 28, nr 2, 2; 39-46
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dual infection of urinary tract with Enterocytozoon bieneusi and Encephalitozoon cuniculi in HIV/AIDS patients
Autorzy:
Wesolowska, M.
Szetela, B.
Kicia, M.
Kopacz, Z.
Sak, B.
Rymer, W.
Kvac, M.
Salamatin, R.
Powiązania:
https://bibliotekanauki.pl/articles/5667.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Parazytologiczne
Źródło:
Annals of Parasitology; 2019, 65, 1
0043-5163
Pojawia się w:
Annals of Parasitology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies