Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Shen, Xiaowei" wg kryterium: Wszystkie pola


Wyświetlanie 1-1 z 1
Tytuł:
A feedback weighted fusion algorithm with dynamic sensor bias correction for gyroscope array
Autorzy:
Yuan, Ding
Qin, Yongyuan
Shen, Xiaowei
Wu, Zongwei
Powiązania:
https://bibliotekanauki.pl/articles/1848956.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
inertial sensor
gyroscope array
weighted fusion
bias correction
Opis:
Low-cost Micro-Electromechanical System (MEMS) gyroscopes are known to have a smaller size, lower weight, and less power consumption than their more technologically advanced counterparts. However, current low-grade MEMS gyroscopes have poor performance and cannot compete with quality sensors in high accuracy navigational and guidance applications. The main focus of this paper is to investigate performance improvements by fusing multiple homogeneous MEMS gyroscopes. These gyros are transformed into a virtual gyro using a feedback weighted fusion algorithm with dynamic sensor bias correction. The gyroscope array combines eight homogeneous gyroscope units on each axis and divides them into two layers of differential configuration. The algorithm uses the gyroscope array estimation value to remove the gyroscope bias and then correct the gyroscope array measurement value. Then the gyroscope variance is recalculated in real time according to the revised measurement value and the weighted coefficients and state estimation of each gyroscope are deduced according to the least square principle. The simulations and experiments showed that the proposed algorithm could further reduce the drift and improve the overall accuracy beyond the performance limitations of individual gyroscopes. The maximum cumulative angle error was -2.09 degrees after 2000 seconds in the static test, and the standard deviation (STD) of the output fusion value of the proposed algorithm was 0.006 degrees/s in the dynamic test, which was only 1.7% of the STD value of an individual gyroscope.
Źródło:
Metrology and Measurement Systems; 2021, 28, 1; 161-179
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies