Tytuł:
Modelowanie oddziaływań dynamicznych w strukturze MASTER - SLAVE telemanipulatora torakoskopowego Robin Heart 1
Modelling of dynamical interaction in MASTER - SLAVE structure of thoracoscope telemanipulator Robin Heart 1
Autorzy:
Ilewicz, G.
Tejszerska, D.
Powiązania:
https://bibliotekanauki.pl/articles/98832.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
robot kardiochirurgiczny
telemanipulator chirurgiczny
Robin Heart
telemanipulator torakoskopowy
model dynamiczny
cardiosurgical robot
surgery telemanipulator
thoracoscope telemanipulator
dynamic model
Opis:
W pracy zaprezentowano bryłowy model dynamiczny w strukturze MASTER - SLAVE telemanipulatora torakoskopowego Robin Heart 1 zbudowany w celu próby odwzorowania zjawisk siłowych, tribologicznych oraz stanów naprężenia powstałych podczas ruchu. Model umożliwia rozwiązanie zagadnienia dynamiki w sposób iteracyjny dla dwóch głównych elementów systemu telemanipulatora. Pierwszy to zadajnik przemieszczeń i sił wzorowany na przyrządzie endoskopowym. Drugi to ramię manipulatora o kinematyce sferycznej i sumarycznej ruchliwości równej 12. Elementy systemu są ze sobą sprzężone kinematycznie. W celu szybkiej zmiany kształtu brył składowych modelu zastosowano parametryczny sposób konstruowania geometrii oraz tworzenia par kinematycznych. Daje to możliwość modyfikowania parametrów inercyjnych dla ruchu postępowego i obrotowego modelu poprzez zmianę przekrojów profili. Zagadnienie dynamiki polegające na wyznaczeniu sił i momentów sił zostało rozwiązane przy zastosowaniu solvera programu Adams. Natomiast stan naprężeń, przemieszczeń i odkształceń jest modelowany przy użyciu aplikacji MES, CosmosWorks. W procesie iteracyjnym wyznaczane jest maksymalne naprężenie powstałe w analizowanym ciele na skutek modelowanych oddziaływań dynamicznych i dla tej chwili czasu generowane są mapy naprężeń redukowanych wg energetycznej hipotezy Hubera. Dyskretyzacji ciał dokonano elementem typu tetra czterowęzłowym o 12. stopniach swobody.
The dynamical solid model in the MASTER-SLAVE structure of thoracoscope telemanipulator Robin Heart 1 is presented in the paper. It was made in order to show forced and frictional phenomena and states of stress that appear during its motion. The model makes possible to solve the problem of dynamics iteratively for two main components of telemanipulator system. The first is the endoscope master tool manipulator of displacements and forces that is patterned on a classical thoracoscope tool. The second is the arm of manipulator. The workspace of it is spherical and the number of mobility is 12. The elements of the system are coupling kinematically. Parametrical method constructing of the geometry and kinematic pairs was applied in order to fast modification of shapes of solid components of the model. It gives possibility of modifying of inertia parameters for linear and angular motion of model through change of the sections of profiles. The problem of dynamics consisting in to determine forces and moments of forces was solved by using solver of the programme Adams. However, state of stresses, displacements and strains are modeled by using of the MES application CosmosWorks. In the iteration process maximal stress is calculated in the analyzed body as a result of dynamical interaction and for this moment of time the diagrams of reduced stress are generated according to energetic hyphotesis of Huber. The digitizing of bodies was made by using tetrahedral elements that have got three translational degrees of freedom per every of 4 node.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 69-74
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pierwsze eksperymenty na zwierzętach robota chirurgicznego Robin Heart
The Robin Heart system in vivo experiments - arrangement report
Autorzy:
Nawrat, Z.
Kostka, P.
Dybka, W.
Rohr, K.
Podsędkowski, L.
Śliwka, J.
Cichoń, R.
Zembala, M.
Religa, G.
Powiązania:
https://bibliotekanauki.pl/articles/275516.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
roboty chirurgiczne
machatroniczne narzędzia chirurgiczne
surgical robots
mechatronic surgical tools
Opis:
Prezentowana praca przedstawia aktualne prace prowadzone w zabrzańskim zespole związane z projektem robota chirurgicznego Robin Heart oraz mechatronicznych narzędzi chirurgicznych Robin Heart Uni System. Projekt wkroczył w fazę eksperymentu na zwierzętach. W styczniu 2009 r. wykonano eksperymentalne operacje na świniach: usunięcia woreczka żółciowego oraz elementy operacji naprawczych zastawki mitralnej i trójdzielnej. Planowany zabieg pomostowania naczyń wieńcowych TECAB przełożono na inny termin. Cel eksperymentów został osiągnięty: wskazano obszar niezbędnych zmian, udoskonaleń, które będą wprowadzone do opracowywanych urządzeń w ramach opracowania technologii produkcji seryjnej przed wdrożeniem klinicznym.
Current works led in Zabrze's team connected with the project of Robin Heart surgical robot as well as the Robin Heart Uni System mechatronic surgical tools are presented. The project entered in the phase of experiment on animals. Two operations on pigs: cholecystectomia and the elements of repair operation of mitral and tricuspid valve were carried out in January 2009. TECAB - the operation the coronary by-pass on beating heart - has been postponed for another date. The goal of two mentioned experiments were achieved: the range of indispensable changes which will be introduced to worked out devices in study of technology of serial production before clinical application.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 2; 539-545
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The finite difference method in the 2D Fourier equation with Robin’s boundary condition
Autorzy:
Biernat, G.
Lara-Dziembek, S.
Pawlak, E.
Powiązania:
https://bibliotekanauki.pl/articles/122782.pdf
Data publikacji:
2013
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
block matrices
n-band matrices
determinant
Fourier equation
boundary condition
Opis:
This paper contains the application of the Finite Difference Method in the two-dimensional Fourier equation using Robin’s boundary condition (the third boundary condition).
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2013, 12, 4; 5-11
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The 3D Fourier equation with the Robin’s boundary condition using the finite difference method
Autorzy:
Biernat, G.
Lara-Dziembek, S.
Pawlak, E.
Powiązania:
https://bibliotekanauki.pl/articles/123013.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
block matrices
determinant
Fourier equation
boundary condition
macierze blokowe
determinanta
równanie Fouriera
warunek brzegowy
Opis:
This article is a continuation of the discussion on the two-dimensional Fourier equation with Robin’s boundary condition. In the paper the Finite Difference Method is applied.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2014, 13, 1; 5-11
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robin Heart INCITE - wprowadzenie sprzężenia siłowego dla telemanipulatora chirurgicznego
Robin Heart INCITE - application of haptic feedback to surgical telemanipulator
Autorzy:
Nawrat, Z.
Mucha, Ł.
Rohr, K.
Lis, K.
Lehrich, K.
Krawczyk, D.
Földesy, P.
Radó, J.
Dücső, C.
Sántha, H.
Szebényi, G.
Fürjes, P.
Powiązania:
https://bibliotekanauki.pl/articles/2063838.pdf
Data publikacji:
2016
Wydawca:
Międzynarodowe Stowarzyszenie na rzecz Robotyki Medycznej
Tematy:
robot chirurgiczny
czujnik siły
czujnik dotykowy
chirurgia minimalnie inwazyjna
siłowe sprzężenie zwrotne
haptyczny
surgical robot
force sensor
tactile sensor
minimal invasive surgery
MIS
force feedback
haptic
Opis:
Celem pracy jest przedstawienie rozwoju projektu systemu sterowania robota Robin Heart z zastosowaniem specjalnych mikro--czujników 3D MEMS, dla weryfikacji ich następujących funkcji: 1) sterowanie robotem toru endoskopowego za pomocą mikro--dżojstika zintegrowanego z rękojeścią narzędzia laparoskopowego dla ergonomicznej manipulacji. 2) pomiar wartości i kierunku działania siły pomiędzy szczęką narzędzia laparoskopowego, a organem. 3) diagnostyki tkanek podczas pracy za pomocą czujnika dotykowego 3D umieszczonego w czołowej części narzędzia. Piezorezystancyjne sensory krzemowe zostały zaprojektowane i wykonane przez węgierską firmę EK MFA. Przeprowadzone zostały symulacje MES w celu określenia podstawowych parametrów mechanicznych czujnika. Czujniki zostały pokryte polimerem półprzewodnikowym PDMS (polidimetylosiloksan), następnie przeprowadzono badania wpływu powłoki elastycznej pod kątem czułości i czasu odpowiedzi. Zgodnie z wymaganiami medycznymi i funkcjonalnymi czujniki dodatkowo zostały pokryte biokompatybilnym elastycznym polimerem. Wykonany został prototyp miniaturowego zadajnika ruchu umieszczonego na części chwytowej narzędzia laparoskopowego. Przeprowadzone zostały testy polegające na orientacji robota w polu operacyjnym za pomocą trójosiowego czujnika siły. Przeprowadzono wstępne testy sensorycznego narzędzia laparoskopowego zintegrowanego z robotem ROBIN HEART i zadajnikiem ruchu Robin Hand. Zrealizowane badania prototypowych czujników wykazały ich użyteczność w układzie siłowego sprzężenia zwrotnego robota. Potwierdzono celowość aplikacji do oceny stanu tkanki i siły zacisku graspera laparoskopowego. Praca została wykonana w ramach projektu EU INCITE finansowana częściowo przez NCBiR.
The aim of this work is to demonstrate the applicability and functionality of the Robin Heart robot's control systems integrated with special MEMS based 3D force micro-sensors. Three different robot functions and corresponding detector devices are proposed: 1) Micro-joystick type actuator to be integrated in the hilt of the laparoscope to control easily robotic movement during operation. 2) 1D force sensor located inside the laparoscopic jaw to provide feedback to the surgeon by measuring the grasping strength and 3) 3D (vectorial) force/tactile sensor placed at the tip of the laparoscope which facilitates palpation for tissue diagnostics during operation. The silicon based piezoresistive sensors have been designed and prepared by micromachining technologies in the MEMS Laboratory of EK MFA (Budapest, Hungary). According to the medical and functional requirements the sensors were electro-mechanically integrated and covered by biocompatible elastic polymer (polydimethylsiloxane – PDMS) by BME (Budapest, Hungary). The device geometry was modelled by coupled finite element simulation to determine its expected performance. The effect of the elastic coverage was studied in terms of sensitivity and response time also. Preliminary test of the laparoscopic head equipped with MEMS sensors and integrated in the ROBIN HEART surgery robot system was performed by FRK (Zabrze, Poland). A model of the robot controller using a prototype of 3D force sensor has been also successfully tested during the tests of the functional robot. Studies of the prototypes of “smart” sensory laparoscopes have demonstrated their remarkable usefulness in force feedback robotic systems to recognize the state of tissue and to determine the clamping force of the grasper of surgical system. The international cooperation to develop “smart” laparoscope for robotic surgery was done in the frame of the ENIAC “INCITE” project No.621278 and partially financed by the ENIAC JU and the National Centre for Research and Development (NCBR - Poland) and National Research, Development and Innovation Fund (NKFIA – Hungary).
Źródło:
Medical Robotics Reports; 2016, 5; 34--42
2299-7407
Pojawia się w:
Medical Robotics Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synteza stałopunktowego mechanizmu robota medycznego dla potrzeb chirurgii minimalnego urazu
Synthesis of constant point mechanism of medical robot for needs of minimally invasive surgery
Autorzy:
Ilewicz, G.
Powiązania:
https://bibliotekanauki.pl/articles/98972.pdf
Data publikacji:
2008
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
telemanipulator kardiochirurgiczny
chirurgia małoinwazyjna
robot medyczny
Robin Heart
cardiosurgical telemanipulator
minimally invasive surgery
medical robot
Opis:
W pracy przedstawiono rozwiązania konstrukcyjne telemanipulatorów kardiochirurgicznych stosowanych w chirurgii minimalnego urazu. Szczególną uwagę skierowano na rozważa dotyczące implementacji mechanizmów równoległowodowych zapewniających stałopunktowość kinematyczną z punktem stałym umiejscowionym poza ramieniem robota. Zaproponowano wprowadzenie modyfikacji w geometrii łańcucha kinematycznego telemanipulatora oraz zwiększenie ruchliwości w celu rozszerzenia możliwości operacyjnych podczas wykonywania procedur minimalnie inwazyjnych.
Constructions of cardiosurgical telemanipulators applied in minimally invasive surgery are presented in this paper. Special attention was aimed on considerations relating implementations of parallel mechanisms which realize constant point kinematics with a constant point positioned outside the robots arm. Modifications of geometry of telemanipulator kinematic chain and enlargement of mobility in order to increase surgical possibility during minimally invasive procedures are proposed in this paper.
Źródło:
Aktualne Problemy Biomechaniki; 2008, 2; 79-82
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robin Heart INCITE surgical telemanipulator controlled by system equipped with 3D force sensor
Robin Heart INCITE – telemanipulator chirurgiczny sterowany przez system wyposażony w czujnik siły 3D
Autorzy:
Nawrat, Z.
Mucha, Ł.
Krawczyk, D.
Lis, K.
Lehrich, K.
Rohr, K.
Földesy, P.
Radó, J.
Dücső, C.
Sántha, H.
Szebényi, G.
Fürjes, P.
Powiązania:
https://bibliotekanauki.pl/articles/2063804.pdf
Data publikacji:
2017
Wydawca:
Międzynarodowe Stowarzyszenie na rzecz Robotyki Medycznej
Tematy:
surgical robot
force sensor
tactile sensor
minimal invasive surgery
MIS
force feedback
haptic
robot chirurgiczny
czujnik siły
czujnik dotykowy
chirurgia minimalnie inwazyjna
sprzężenie zwrotne siły
Opis:
The aim of this work is to present the final report, financed by the EU INCITE grant, development of the robot control system Robin Heart with the use of special 3D MEMS micro-sensors, to verify their following functions: 1) an easy control of robotic movement during operation using a micro joystick integrated with the laparoscopic tool 2) measuring the value and direction of force between the jaw of the laparoscopic tool and operated organ 3) tissue diagnostics during work using a 3D touch sensor placed in the front of the tool. Piezo-resistive silicon sensors have been designed and manufactured by the Hungarian company EK MFA. A prototype of a miniature motion sensor placed on the gripping part of the endoscopic tool to control the vision path robot was made. Sensory endoscopic tools were integrated with the ROBIN HEART robot and the Robin Hand motion unit as well as innovative mechatronic surgical tools with a panel informing about the measurement values of the force of tools and tissue. Researched prototype sensors have demonstrated their usefulness in the robot's force feedback system. The practicality of the application to assess the condition of the tissue and the strength of the endoscopic grasper clamp was confirmed. The work was carried out as a part of the EU INCITE project financed partly by NCBiR and NKFIA.
Celem pracy jest przedstawienie finalnego raportu finansowanego z projektu EU INCITE rozwoju projektu systemu sterowania robota Robin Heart z zastosowaniem specjalnych mikro-czujników 3D MEMS, dla weryfikacji ich następujących funkcji: 1) sterowanie robotem toru endoskopowego za pomocą mikro-dżojstika zintegrowanego z rękojeścią narzędzia laparoskopowego dla ergonomicznej manipulacji. 2) pomiar wartości i kierunku działania siły pomiędzy szczęką narzędzia laparoskopowego, a organem. 3) diagnostyki tkanek podczas pracy za pomocą czujnika dotykowego 3D umieszczonego w czołowej części narzędzia. Piezorezystancyjne sensory krzemowe zostały zaprojektowane i wykonane przez węgierską firmę EK MFA. Wykonany został prototyp miniaturowego zadajnika ruchu umieszczonego na części chwytowej narzędzia endoskopowego do sterowania robotem toru wizyjnego. Wykonano sensoryczne narzędzia endoskopowe zintegrowane z robotem ROBIN HEART i zadajnikiem ruchu Robin Hand oraz nowatorskie mechatroniczne narzędzia chirurgiczne z panelem informującym o wartości pomiarów siły oddziaływania narzędzi z tkanką. Zrealizowane badania prototypowych czujników wykazały ich użyteczność w układzie siłowego sprzężenia zwrotnego robota. Potwierdzono celowość aplikacji do oceny stanu tkanki i siły zacisku graspera endoskopowego. Praca została wykonana w ramach projektu EU INCITE finansowana częściowo przez NCBiR i NKFIA.
Źródło:
Medical Robotics Reports; 2017, 6; 37--46
2299-7407
Pojawia się w:
Medical Robotics Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pancyclicity when each Cycle Must Pass Exactly k Hamilton Cycle Chords
Autorzy:
Affif Chaouche, Fatima
Rutherford, Carrie G.
Whitty, Robin W.
Powiązania:
https://bibliotekanauki.pl/articles/31339337.pdf
Data publikacji:
2015-08-01
Wydawca:
Uniwersytet Zielonogórski. Wydział Matematyki, Informatyki i Ekonometrii
Tematy:
extremal graph theory
pancyclic graph
Hamilton cycle
Opis:
It is known that Θ(log n) chords must be added to an n-cycle to produce a pancyclic graph; for vertex pancyclicity, where every vertex belongs to a cycle of every length, Θ(n) chords are required. A possibly ‘intermediate’ variation is the following: given k, 1 ≤ k ≤ n, how many chords must be added to ensure that there exist cycles of every possible length each of which passes exactly k chords? For fixed k, we establish a lower bound of Ω(n1/k) on the growth rate.
Źródło:
Discussiones Mathematicae Graph Theory; 2015, 35, 3; 533-539
2083-5892
Pojawia się w:
Discussiones Mathematicae Graph Theory
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robin Heart Force Feedback/Control System Based on INCITE Sensors - preliminary study
Autorzy:
Rohr, K.
Fürjes, P.
Mucha, Ł.
Radó, J.
Lis, K.
Dücső, C.
Sadowski, W.
Foldesy, P.
Krawczyk, D.
Kroczek, P.
Małota, Z.
Szebényi, G.
Nawrat, Z.
Powiązania:
https://bibliotekanauki.pl/articles/2063850.pdf
Data publikacji:
2015
Wydawca:
Międzynarodowe Stowarzyszenie na rzecz Robotyki Medycznej
Tematy:
force sensors
surgical tools
medical robotics
force feedback
czujniki siły
narzędzia chirurgiczne
robotyka medyczna
siłowe sprzężenie zwrotne
Opis:
The subject aim of the this work is the investigation studying of applicability of 3D MEMS based force micro-sensors made by 3D MEMSmicromachining technology and use it as micro-joystick to control the position of robot Robin Heart PVA. Since the robot moves with 5 degrees of freedom to run utilise all the possibilities of movement is done available by the use of the switching clutch control object. By pressing the in appropriate mode (way) the sensor provides the ability to control the functions of the spherical robot (at different speeds): to lean forward or sideways or alternatively to penetrate or withdrow withdraw and to rotate of the tool axis is possible. The sensor was fastened in its special of the surgical tool. An Applicability of appropriate control system equipped with a new this novel sensor was investigated in and a comparison with to the control using the classic remote control methods was investigated. Preliminary tests of laparoscope integrated force sensors were also investigated accomplished to provide additional on-line information for the surgeron during operation.
Przedmiotem pracy jest wykonanie czujnika siły 3D wg technologii MEMs i zastosowanie go jako mikrodżojstika siłowego do sterowania położeniem robota Robin Heart PVA. Ponieważ robot posiada 5 stopni swobody uruchomienie wszystkich możliwości ruchu jest wykonane przez zastosowanie sprzęgła przełączającego obiekt sterowania. Poprzez odpowiednie naciśnięcie czujnika uzyskujemy możliwość sterowania funkcjami tego sferycznego robota (z różną prędkością): pochylenie do przodu lub w bok lub alternatywnie wsuw/wysuw liniowy i obrót narzędzia wokół osi. Wykonano specjalny projekt umieszczenia czujnika w odpowiednim uchwycie mocowanym do narzędzia chirurgicznego. Wykonano odpowiedni system sterowania z nowym czujnikiem i dokonano porównania ze sterowaniem za pomocą klasycznego pilota.
Źródło:
Medical Robotics Reports; 2015, 4; 10--17
2299-7407
Pojawia się w:
Medical Robotics Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies